Plan Review Details - Project Z19040020
| Plan Review Stops For Project Z19040020 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
05-06-2019 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
05-06-2019 |
Time |
19:34 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
05-06-2019 |
Time |
19:33 |
Sent To |
|
|
| Notes |
| 2019-05-06 19:38:43 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. DEMOLITION OF THE EXISTING BUILDING. AN ASBESTOS | | | SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT | | | REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH | | | COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963, | | | OR BY EMAIL: [email protected] | | | | | | 3. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 4. GREASE AND PETROL INTERCEPTOR. A GREASE ABD PETROL | | | INTERCEPTORS WILL BE REQUIRED. PLEASE CONTACT JEFFREY | | | ODOMS, UTILITIES O&M SUPERINTENDENT, PUBLIC UTILITIES | | | DEPARTMENT, FATS OILS AND GREASE DIVISION, AT (561) | | | 822-2172, OR BY EMAIL: [email protected] | | | | | | 5. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 6. ART IN PUBLIC PLACES. THIS PROJECT MAY BE SUBJECT TO | | | ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE ON | | | THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
08-28-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
08-28-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
08-28-2019 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
05-02-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
05-02-2019 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
05-02-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-05-02 12:49:58 | PROVIDE STORMWATER POLLUTION PREVENTION PLAN FOR | | | ENGINEERING SUBMITTALS. | | | | | | PROVIDE PROFILE AND CLEARANCES AT ALL UTILITY | | | CROSSINGS. | | | | | | PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | | AREAS. | | | | | | PROVIDE DEMANDS FOR WATER (PROPOSED DOMESTIC AND | | | IRRIGATION) AND SEWER (AVERAGE, MAXIMUM & PEAK) AND | | | FIRE FLOW DEMANDS. CALCULATIONS SHALL BE PER FAC 64E-6 | | | FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | PLEASE PROVIDE MORE DETAILS ON DRAINAGE CONNECTION; | | | DRAINAGE FROM NORTH PROPERTY MAY AFFECT YOUR ONSITE | | | DRAINAGE. | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
04-30-2019 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
04-30-2019 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
04-30-2019 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2019-04-30 10:35:03 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | THE FOLLOWING COMMENTS MAY BE MORE RELATED TO BUILDING | | | PLAN SUBMITTAL: | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE, | | | AND WHETHER IT IS MIXED OR SEPARATED OCCUPANCY. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND | | | SUBMITTED WITH THE MASTER PLAN. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. THE PROPOSED ENTRANCE OFF OF 45TH ST INDICATES A | | | 16' LANE WIDTH. THIS ACCESS WOULD BE USED BY | | | FIREFIGHTER VEHICLES AND CONSIDERED FIRE DEPARTMENT | | | ACCESS ROAD AND IS REQUIRED TO BE 20'. PLEASE REVIEW | | | AND CORRECT IF POSSIBLE. REVIEW ANY CONCERNES WITH THE | | | OFFICE OF THE FIRE MARSHAL. | | | | | | 12. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE | | | SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY | | | DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 13. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | 14. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
08-28-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
08-28-2019 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
08-14-2019 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2019-08-28 16:28:50 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: RACE TRAC 45TH ST Z19040020 | | | AUGUST 14, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. MAKE THE FOLLOWING CORRECTIONS TO THE | | | TREE DISPOSITION PLAN SHEET TD-1: | | | ? CORRECT CRAPE MYRTLE TREE #10 TO CATEGORY 2 AND 150 | | | SQ FT CANOPY MITIGATION. | | | ? ALL NATIVE TREES AND PALMS IN GOOD CONDITION MUST BE | | | PRESERVED OR RELOCATED, AND NATIVE TREES #9 AND 46 ARE | | | SHOWN IN GOOD CONDITION. | | | | | | 2. SATISFIED. SOME LANDSCAPE TERMINAL ISLANDS DO NOT | | | MEET THE CODE REQUIREMENTS OF SECTION 94-443(C)(3)A. | | | FOR LANDSCAPE AREA WIDTH OF 8 FEET INSIDE CURB FOR THE | | | FULL LENGTH OF THE PARKING SPACE. THE TERMINAL ISLANDS | | | SHADE TREES ARE MISSING IN THE NORTHWEST CORNER OF THE | | | PARKING AREA WEST OF THE BUILDING AND SOUTH SIDE OF THE | | | 5 SPACE ROW WEST OF THE CANOPY. REVISE PLAN TO MEET | | | REQUIREMENTS. | | | | | | 3. SATISFIED. THE DETAIL #9 ON SHEET LP.2 SHOWING THE | | | PARKING AREA SURFACE CALCULATIONS, PARKING SPACE AREAS | | | AND LANDSCAPE AREAS PROVIDED TO DEMONSTRATE COMPLIANCE | | | WITH SECTIONS 94-443 (C)(3) AND (4) NEEDS TO BE | | | ADJUSTED TO ONLY INCLUDE AREAS WITHIN EDGES OF THE | | | PARKING FIELD. ADJUST FOR AREAS CORRECTED PER COMMENT | | | #2 ABOVE. | | | | | | 4. SATISFIED. SHOW OFFSITE TREES PER SECTION | | | 94-442(B)(2)Q. THE NORTH AND EAST BUFFER, AND THE | | | NORTHERN PORTION OF THE WEST BUFFER ARE OF CONCERN. | | | | | | 5. SATISFIED. THE RELOCATED LARGE LIVE OAK TREE IS | | | PROPOSED IN A LOCATION THAT CONFLICTS WITH EXISTING | | | TREE CANOPY AND UTILITY LINES. IT SHOULD BE RELOCATED | | | TO AN AREA THAT DOES NOT HAVE CONFLICTS, POSSIBLY TO | | | THE SOUTH. | | | | | | 6. SATISFIED. ALL CURBS ADJACENT TO LANDSCAPE AREAS | | | MUST MEET THE CODE REQUIREMENT OF A TYPE D NON | | | MOUNTABLE CURB PER SECTION 94-443(C)(5). | | | | | | 7. PARTIALLY SATISFIED. SHOW PROOF OF PROVIDING THE | | | EFFICIENT IRRIGATION OR MOISTURE SENSOR AS CLAIMED ON | | | THE FLORIDA FRIENDLY DESIGN OPTION CHART. ADDITIONAL | | | SHADE TREES IN THE VEHICULAR USE AREA IS NOT VALID. | | | STAFF SUGGESTS LOOKING AT THE TREE AND SHRUB CATEGORIES | | | TO CAPTURE ADDITIONAL POINTS FOR DROUGHT TOLERANT | | | SPECIES AS 25-50% OF THE TOTALS. | | | EACH CATEGORY CAN ONLY BE 51% IN ONE, NOT TWO POINTS. | | | EXAMPLE: TREES- 51% OR MORE NATIVE AND 25-50% DROUGHT | | | TOLERANT ARE POSSIBLE BUT 51% CANNOT BE COUNTED TWICE. | | | | | | 8. SATISFIED. PROVIDE MORE ADEQUATE BUILDING PERIMETER | | | LANDSCAPE. THE ADDITION OF PLANTINGS IN THE FRONT OF | | | THE BUILDING IS ENCOURAGED, AS OUTDOOR STORAGE IS | | | PROHIBITED. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | RIGHT OF WAY LANDSCAPING AND IRRIGATION APPROVED WITH | | | THIS PETITION. | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION AS PERMITTED AND | | | INSTALLED. THIS WILL BE THROUGH A SEPARATE MAINTENANCE | | | AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
05-03-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
05-03-2019 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
05-03-2019 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2019-05-03 16:32:54 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: RACE TRAC 45TH ST Z19040020 | | | MAY 3, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. MAKE THE FOLLOWING CORRECTIONS TO THE TREE | | | DISPOSITION PLAN SHEET TD-1: | | | ? CORRECT CRAPE MYRTLE TREE #10 TO CATEGORY 2 AND 150 | | | SQ FT CANOPY MITIGATION. | | | ? ALL NATIVE TREES AND PALMS IN GOOD CONDITION MUST BE | | | PRESERVED OR RELOCATED, AND NATIVE TREES #9 AND 46 ARE | | | SHOWN IN GOOD CONDITION. | | | | | | 2. SOME LANDSCAPE TERMINAL ISLANDS DO NOT MEET THE CODE | | | REQUIREMENTS OF SECTION 94-443(C)(3)A. FOR LANDSCAPE | | | AREA WIDTH OF 8 FEET INSIDE CURB FOR THE FULL LENGTH OF | | | THE PARKING SPACE. THE TERMINAL ISLANDS SHADE TREES ARE | | | MISSING IN THE NORTHWEST CORNER OF THE PARKING AREA | | | WEST OF THE BUILDING AND SOUTH SIDE OF THE 5 SPACE ROW | | | WEST OF THE CANOPY. REVISE PLAN TO MEET REQUIREMENTS. | | | | | | 3. THE DETAIL #9 ON SHEET LP.2 SHOWING THE PARKING AREA | | | SURFACE CALCULATIONS, PARKING SPACE AREAS AND LANDSCAPE | | | AREAS PROVIDED TO DEMONSTRATE COMPLIANCE WITH SECTIONS | | | 94-443 (C)(3) AND (4) NEEDS TO BE ADJUSTED TO ONLY | | | INCLUDE AREAS WITHIN EDGES OF THE PARKING FIELD. ADJUST | | | FOR AREAS CORRECTED PER COMMENT #2 ABOVE. | | | | | | 4. SHOW OFFSITE TREES PER SECTION 94-442(B)(2)Q. THE | | | NORTH AND EAST BUFFER, AND THE NORTHERN PORTION OF THE | | | WEST BUFFER ARE OF CONCERN. | | | | | | 5. THE RELOCATED LARGE LIVE OAK TREE IS PROPOSED IN A | | | LOCATION THAT CONFLICTS WITH EXISTING TREE CANOPY AND | | | UTILITY LINES. IT SHOULD BE RELOCATED TO AN AREA THAT | | | DOES NOT HAVE CONFLICTS, POSSIBLY TO THE SOUTH. | | | | | | 6. ALL CURBS ADJACENT TO LANDSCAPE AREAS MUST MEET THE | | | CODE REQUIREMENT OF A TYPE D NON MOUNTABLE CURB PER | | | SECTION 94-443(C)(5). | | | | | | 7. SHOW PROOF OF PROVIDING THE EFFICIENT IRRIGATION OR | | | MOISTURE SENSOR AS CLAIMED ON THE FLORIDA FRIENDLY | | | DESIGN OPTION CHART. ADDITIONAL SHADE TREES IN THE | | | VEHICULAR USE AREA IDS NOT VALID. STAFF SUGGESTS | | | LOOKING AT THE TREE AND SHRUB CATEGORIES TO CAPTURE | | | ADDITIONAL POINTS FOR DROUGHT TOLERANT SPECIES AS | | | 25-50% OF THE TOTALS. | | | | | | 8. PROVIDE MORE ADEQUATE BUILDING PERIMETER LANDSCAPE. | | | THE ADDITION OF PLANTINGS IN THE FRONT OF THE BUILDING | | | IS ENCOURAGED, AS OUTDOOR STORAGE IS PROHIBITED. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | RIGHT OF WAY LANDSCAPING AND IRRIGATION APPROVED WITH | | | THIS PETITION. | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION AS PERMITTED AND | | | INSTALLED. THIS WILL BE THROUGH A SEPARATE MAINTENANCE | | | AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
P |
Date |
05-03-2019 |
|
|
Cont ID |
|
| Sent By |
|
Date |
05-07-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
05-03-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-05-07 16:16:33 | PUBLIC WORKS HAS NO OBJECTIONS TO THE PROPOSED PROJECT. | | | | | | MATT HEJAZI | | | DEPARTMENT OF PUBLC WORKS | | | 561-822-2045 |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
08-28-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
08-28-2019 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
08-28-2019 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2019-08-28 11:47:40 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | 8/7/19 ROUTED SUBMITTAL PACKAGE: | | | | | | 1. SHOW GRADING FOR EXTENDING THE SWALE ALONG 45TH | | | STREET FROM WEST OF THE EXISTING DRIVEWAY (THAT WILL BE | | | REMOVED) TO THE NEW DRIVEWAY LOCATION. | | | | | | 2. SHOW HOW THE EAST SIDE OF THE PROPOSED SIDEWALK FROM | | | 45TH STREET WILL BE GRADED TO MATCH EXISTING, | | | PARTICULARLY ADJACENT TO THE EXISTING UTILITY | | | FACILITIES. | | | | | | 3. ON THE SITE PLAN, SHEET #SP.1, SHOW THE STOP BAR | | | STRIPING A MINIMUM OF 4 FEET FROM THE BACK OF SIDEWALK | | | ALONG 45TH STREET. | | | | | | 4. ON THE SITE PLAN, SHEET #SP.1, ADD THE PLAT BOOK AND | | | PAGE FOR THE PROPERTY TO THE EAST OF THE RACETRAC SITE. | | | REMOVE "UNPLATTED". | | | | | | 5. SHOW ON THE LANDSCAPE PLANS THE PROPOSED YARD DRAINS | | | NEXT TO THE BUILDING. | | | | | | 6. SHOW ON THE PRELIMINARY CIVIL PLANS, SHEET C1, BY | | | WAY OF HATCHING, WHERE NEW PAVEMENT WILL BE CONSTRUCTED | | | OR REGRADED. | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 | | | | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
05-07-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
05-07-2019 |
Time |
18:27 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
05-07-2019 |
Time |
18:28 |
Sent To |
|
|
| Notes |
| 2019-05-07 18:28:29 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. CONSIDER REDUCING THE LENGTH OF PARKING SPACES AND | | | PROVIDING 2? PARKING OVERHANG FOR THE PARKING SPACES | | | FACING WEST IN THE NEW PARKING LOT WEST OF THE BUILDING | | | AND THE RECONFIGURED PARKING SOUTHWEST OF THE FUEL | | | PUMPS. | | | | | | 2. REVIEW THE ORIGINAL GRADING PLAN FOR THE DETENTION | | | AREA EAST OF THE BUILDING AND DETERMINE IF THIS AREA | | | NEEDS TO BE REGRADED. | | | | | | 3. ELEVATION OF NEW TRENCH DRAIN FOR WEST DRIVEWAY | | | SHOULD NOT BE BELOW THE MINIMUM PERMITTED PERIMETER | | | ELEVATION. | | | | | | 4. ARE THE GREASE TRAPS IN A SERVICEABLE LOCATION. | | | CONSIDER RELOCATING THE SEWER LINE FROM THE GREASE | | | TRAPS AWAY FROM THE EXISTING TREES. | | | | | | 5. 45TH STREET IS MAINTAINED BY FDOT OR PALM BEACH | | | COUNTY. FDOT OR COUNTY APPROVAL WILL BE NEEDED FOR | | | PROPOSED IMPROVEMENTS IN THE 45TH ST. RIGHT OF WAY. | | | | | | 6. STOP BARS SHOULD BE LOCATED MINIMUM 4 FEET FROM | | | SIDEWALKS. | | | | | | 7. ADD PLAT BOOK AND PAGE (103/10) FOR HARLEY DAVIDSON | | | PROPERTY TO THE EAST. | | | | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE A COPY OF THE SFWMD ERP MODIFICATION PRIOR | | | TO STARTING CONSTRUCTION. | | | | | | 4. PROVIDE A COPY OF THE NPBCID PERMIT MODIFICATION | | | PRIOR TO STARTING CONSTRUCTION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
P |
Date |
09-06-2019 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
09-06-2019 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
05-07-2019 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
05-07-2019 |
Time |
11:26 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-05-07 11:28:45 | 1. CHECK STATUS OF ACCESS EASEMENT IF APPROVAL OF | | | HOLDER IS REQUIRED FOR PROPOSED IMPROVEMENTS. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
09-18-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-09-18 11:27:55 | 1. PROVIDE COUNTY DRIVEWAY LETTER. | | | 2. INCLUDE AUTOTURN EXHIBITS FOR FUEL DELIVERY TRUCKS. | | | 3. NARROW THE DRIVEWAYS TO 24 FEET IF EXTRA WIDTH IS | | | NOT NEEDED, AND HATCH THE EXTRA PAVEMENT WIDTH IF | | | NEEDED FOR TRUCK ACCESS. DRIVEWAY WIDTH SHOULD BE | | | MINIMIZED AND AUTOTURN EXHIBITS SHOULD BE PROVIDED TO | | | SUPPORT DRIVEWAY WIDTH GREATER THAN 24 FEET. | | | 4. PLEASE VERIFY WITH PALM BEACH COUNTY ON THE USE OF | | | RAISED PORK CHOP ISLAND FOR THE DRIVEWAY ON 45TH | | | STREET. | | | 5. PROVIDE INTERNAL CROSS ACCESS TO THE ADJACENT PARCEL | | | TO THE NORTH PER CITY CODE 94-312(2)(C). | | | 6. REMOVE THE REFERENCE OF 45TH STREET AS STATE ROAD ON | | | THE PLAN SHEETS. | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
04-30-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-04-30 17:24:00 | 1. PROVIDE TRAFFIC STATEMENT. | | | 2. PROVIDE COUNTY TPS LETTER. | | | 3. PROVIDE COUNTY DRIVEWAY LETTER. | | | 4. INCLUDE AUTOTURN EXHIBITS FOR FUEL DELIVERY TRUCKS. | | | 5. CONSIDER PROVIDING A PEDESTRIAN CONNECTION ON THE | | | EAST SIDE OF THE PROPERTY BETWEEN 45TH STREET AND THE | | | PROPOSED CONVENIENCE STORE. | | | 6. CONSIDER NARROWING THE DRIVEWAY WIDTH. VERIFY IF THE | | | DRIVEWAY WIDTH OF 36 FEET IS NEEDED. ADDITIONAL | | | PAVEMENT WIDTH BEYOND DRIVEWAY WIDTH OF 24 FEET OR | | | 12-FOOT LANE, IF REQUIRED FOR TRUCK ACCESS, SHOULD BE | | | HATCHED. | | | 7. REMOVE THE REFERENCE OF 45TH STREET AS STATE ROAD ON | | | THE PLAN SHEETS. | | | 8. A 10' X 25' LOADING SPACE IS REQUIRED PER CITY CODE | | | 94-485. | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
05-07-2019 |
|
|
Cont ID |
|
| Sent By |
pgreilic |
Date |
05-07-2019 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
05-07-2019 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2019-05-07 15:21:47 | CASE NUMBER: PB862Z ? Z19040020 | | | PROJECT NAME: RACETRAC REBUILD | | | ADDRESS: 2995 45TH STREET | | | | | | -- CONTACT PAUL GREILICH @ (561) 822-1443 | | | -- PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | -- WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF | | | ELEVEN (11) PAPER COPIES AND AN ELECTRONIC COPY IN | | | .PNG/.PDF FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES | | | ON THE RESUBMITTED PLANS OR THE SUBMITTAL OF | | | INFORMATION/PLANS TO ADDRESS THE COMMENTS MAY RESULT IN | | | ADDITIONAL COMMENTS. | | | -- PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS | | | FROM THE DATE OF THESE COMMENTS/THE PPRC MEETING (BY | | | 7/8/19), THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY | | | FURTHER ACTION SHALL REQUIRE A NEW DEVELOPMENT | | | APPLICATION. | | | -- PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | 1.) ADD SIDEWALK CONNECTION FROM 45TH STREET TO NEW | | | RACETRAC ADJACENT TO EASTERN MOST DRIVE AISLE | | | 2.) ADD PAVERS OR DESIGNATED PEDESTRIAN ENTRY FROM | | | CANOPY/FUELING STATIONS TO CONVENIENCE STORE | | | 3.) ALIGN HANDICAP LOADING ZONE WITH FRONT ENTRANCE TO | | | PROPOSED BUILDING. CONSIDER ADDING A LANDSCAPE ISLAND | | | TO THE WEST OF EITHER SIDE TO FRAME THE ENTRANCE AND | | | PROVIDE SHADING | | | 4.) PLEASE NOTE OUTDOOR STORAGE (ICE, PROPANE) IS | | | PROHIBITED. REVISE ON SITE PLAN AND REPLACE WITH | | | ADDITIONAL FOUNDATION PLANTING | | | 5.) NARROW DRIVE AISLES, 24 FEET PER SEC. 94-485 | | | 6.) LABEL DIMENSIONS OF PARKING SPACES, DRIVE AISLES, | | | DRIVEWAYS, SIDEWALKS | | | 7.) REDUCE THE DEPTH OF PARKING SPACES BY INCLUDING A | | | 2-FOOT GRASS OVERHANG. THE CURB WOULD FUNCTION AS WHEEL | | | STOPS. ALSO CONSIDER THE INCLUSION OF SMALL CAR SPACES | | | TO REDUCE OVERALL IMPERVIOUS SURFACE AREA | | | 8.) THE SITE PLAN SHOWS PARKING SPACES IN EXCESS OF | | | WHAT IS REQUIRED BY CODE. REMOVE EXCESS PARKING SPACES | | | AND CONSIDER REPURPOSING AS LANDSCAPED AREA WITH AN | | | AMENITY SUCH AS A SITTING AREA, TRELLIS, LOCATION OF | | | ART IN PUBLIC PLACES REQUIREMENT, OR COMBINATION OF THE | | | ABOVE | | | 9.) RESTRIPE PARKING SPACES PER SEC. 94-485; REFERENCE | | | DETAIL PROVIDED BY STAFF | | | 10.) APPLICANT SHOULD WEIGH THE INDIVIDUAL | | | CHARACTERISTICS OF THE SITE AND CONSIDER PRESERVING THE | | | MATURE OAK TREE (40? CANOPY) LOCATED TO THE WEST OF THE | | | EXISTING BUILDING AS PART OF THE REDESIGN | | | 11.) ADD ADDITIONAL ARCHITECTURAL FENESTRATION OR | | | DETAILING ALONG THE LEFT AND RIGHT ELEVATIONS | | | (ARCHITECTURAL PLANS) | | | 12.) PROVIDE LETTERS FROM ALL OF THE FOLLOWING PUBLIC | | | UTILITIES CONFIRMING THAT THE PROPOSED PROJECT DOES NOT | | | ENCROACH INTO THEIR EASEMENTS OR OTHERWISE INTERFERE | | | WITH THE PROVISION OF THEIR SERVICES: AT&T, FPU, FPL, | | | AND COMCAST. | | | 13.) PROVIDE A TRAFFIC CONCURRENCY LETTER FROM PALM | | | BEACH COUNTY INDICATING THAT THE PROPOSED PROJECT WILL | | | HAVE NO NEGATIVE IMPACT TO THE TRAFFIC PERFORMANCE OF | | | ROADWAYS WITHIN THE COUNTY. | | | 14.) ALL PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW | | | CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN | | | EXISTING BUILDING, WHERE THE TOTAL CONSTRUCTION COSTS | | | ARE EQUAL OR GREATER THAN $750,000 IS SUBJECT TO THE | | | ART IN PUBLIC PLACES REQUIREMENTS OF CHAPTER 78, | | | ARTICLE V, OF THE CITY?S CODE OF ORDINANCES. CONTACT | | | SYBILLE WELTER @ 561-822-1521 OR [email protected] FOR | | | ADDITIONAL INFORMATION. | | | 15.)PROJECT NARRATIVE ? ADDRESS TO PAUL GREILICH | | | |
|
|
| |