Plan Review Details - Project Z19040015
| Plan Review Stops For Project Z19040015 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
05-06-2019 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
05-06-2019 |
Time |
20:51 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
05-06-2019 |
Time |
20:51 |
Sent To |
|
|
| Notes |
| 2019-05-06 20:56:24 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. DEMOLITION OF THE EXISTING BUILDINGS. AN ASBESTOS | | | SURVEY SHALL BE PERFORMED AND AN ASBESTOS ABATEMENT | | | REPORT SUBMITTED TO THE HEALTH DEPARTMENT PALM BEACH | | | COUNTY OFFICE. CONTACT ALEX ORTEGA AT (561) 837-5963, | | | OR BY EMAIL: [email protected] | | | | | | 3. UNITY OF TITLE. FOR ANY BUILDING CROSSING A PROPERTY | | | LINE, EITHER A RECORDED UNITY OF TITLE, OR SOME OTHER | | | APPROVED LEGAL INSTRUMENT, SHALL BE INCLUDED WITH THE | | | PERMIT APPLICATION, OR THE BUILDING MUST HAVE A FIRE | | | WALL ALONG THE PROPERTY LINE, PER SECTION 202 OF | | | FLORIDA BUILDING CODE, BUILDING, FIRE SEPARATION | | | DISTANCE. | | | | | | 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 5. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND | | | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF SECTION | | | R302 OF FLORIDA BUILDING CODE (RESIDENTIAL) SHALL BE | | | VERIFIED. | | | | | | 6. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 7. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT | | | MICHAEL ORIO, GIS SUPPORT SPECIALIST, AT (561) 494 | | | 1080, OR BY EMAIL: [email protected] | | | | | | 8. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
06-27-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
06-27-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
06-27-2019 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
05-02-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
05-02-2019 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
05-02-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-05-02 12:59:49 | PLEASE SUBMIT A FORMAL AS-BUILT REQUEST FOR ALL CITY OF | | | WEST PALM BEACH-OWNED UTILITIES WITHIN THE PUBLIC RIGHT | | | OF WAY FOR THE ENTIRE EXTENT OF THE LIMITS OF YOUR | | | PROJECT. IDENTIFY TYPE OF UTILITY, LOCATION, PIPE | | | MATERIAL, AGE AND SIZE. PLEASE CONTACT JANICE TARBILL | | | IN THE WPB ENGINEERING SERVICES DEPARTMENT AT | | | [email protected] OR 561-494-1079 FOR FURTHER | | | ASSISTANCE. NOTE THAT FIELD RECORDS ARE FOR INFORMATION | | | ONLY. FIELD VERIFY UTILITY LOCATIONS USING FIELD | | | SURVEY, POT-HOLING, SOFT DIGS ETC. | | | | | | PLEASE SUBMIT COMPLETED LOS ANALYSIS SUMMARY TABLE | | | DIRECTLY TO ENGINEERING (SHEET 33 OF CITY OF WPB | | | DEVELOPMENT APPLICATION). | | | | | | PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER ALONG | | | ENTIRE PROJECT FRONTAGE. | | | | | | PLANS SHALL SHOW PROPOSED LOCATIONS AND DIMENSIONS OF | | | ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | ADDITIONALLY, PLAN VIEW SHALL SHOW ALL EXISTING AND | | | PROPOSED UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER | | | OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. | | | | | | PROVIDE PROFILE AND CLEARANCES AT ALL UTILITY | | | CROSSINGS. | | | | | | SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION | | | (NAVD 88 AND NGVD 29). | | | | | | CUT AND CAP UTILITIES NOT IN USE, AND REMOVE ANY | | | ABANDONED UTILITY LINES LARGER THAN 2 INCHES FROM CITY | | | RIGHT OF WAY. | | | | | | PLEASE PROVIDE CALCULATIONS OF REVISED PERVIOUS AND | | | IMPERVIOUS CALCULATIONS FOR THE PROPOSED IMPACTED | | | AREAS. | | | | | | REMOVE NOTE ON SHEET WS-1 FOR CITY TO INSTALL WATER | | | SERVICES CROSSING LAMBERT AND FOR CITY TO INSTALL SEWER | | | LATERALS. | | | | | | VERIFY MANHOLE ELEVATIONS ON SURVEY AND PLANS AT NORTH | | | END OF ALLEY SECTION. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
04-30-2019 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
04-30-2019 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
04-30-2019 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2019-04-30 16:32:19 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | THE FOLLOWING COMMENTS MAY BE MORE RELATED TO BUIDLING | | | CONSTRUCTION PLAN REVIEW: | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. (SEE BELOW) | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | ALL NEW FIRE HYDRANTS AND IF APPLICABLE, FDC?S PLANNED | | | FOR THIS DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH | | | THE BUREAU OF FIRE PREVENTION. | | | | | | PROPOSED FIRE HYDRANTS AND FDC?S SHOULD BE LOCATED ON | | | THE SAME SIDE OF THE STREET OR ACCESS ROADWAY TO ALLOW | | | FREE ACCESS FOR OTHER ARRIVING EMERGENCY VEHICLES. | | | | | | THERE ARE INDICATIONS ON THE SUBMITTAL MATERIAL OF | | | EXISTING FIRE HYDRANTS LOCATED TO THE EAST AND WEST OF | | | THE PROPOSED PROJECT. ONE OF THOSE HYDRANTS IS LOCATED | | | ACCROSS S DIXIE HIGHWAY. A NEW FIRE HYDRANT MAY BE | | | REQUIRED CLOSER TO THE PROPOSED PROJECT. THE BELOW IS | | | CODE FROM NFPA 1, CHAPTER 18, FIRE DEPARTMENT ACCESS | | | AND WATER SUPPLY. | | | | | | 18.5 FIRE HYDRANTS. | | | 18.5.1 FIRE HYDRANT LOCATIONS AND DISTRIBUTION. FIRE | | | HYDRANTS | | | SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 18.5 FOR | | | ALL NEW | | | BUILDINGS, OR BUILDINGS RELOCATED INTO THE JURISDICTION | | | UNLESS OTHERWISE | | | PERMITTED BY 18.5.1.1 OR 18.5.1.2. | | | | | | 18.5.1.5 WHERE FIRE DEPARTMENT ACCESS ROADS ARE | | | PROVIDED WITH | | | MEDIAN DIVIDERS INCAPABLE OF BEING CROSSED BY FIRE | | | APPARATUS, OR | | | WHERE FIRE DEPARTMENT ACCESS ROADS HAVE TRAFFIC COUNTS | | | OF MORE | | | THAN 30,000 VEHICLES PER DAY, HYDRANTS SHALL BE PLACED | | | ON BOTH | | | SIDES OF THE FIRE DEPARTMENT ACCESS ROAD ON AN | | | ALTERNATING BASIS, | | | AND THE DISTANCES SPECIFIED BY SECTION 18.5 SHALL BE | | | MEASURED | | | INDEPENDENTLY OF THE HYDRANTS ON THE OPPOSITE SIDE OF | | | THE FIRE | | | DEPARTMENT ACCESS ROAD. | | | 18.5.3 BUILDINGS OTHER THAN DETACHED ONE- AND | | | TWO-FAMILY | | | DWELLINGS. FIRE HYDRANTS SHALL BE PROVIDED FOR | | | BUILDINGS OTHER | | | THAN DETACHED ONE- AND TWO-FAMILY DWELLINGS IN | | | ACCORDANCE WITH | | | BOTH OF THE FOLLOWING: | | | (1) THE MAXIMUM DISTANCE TO A FIRE HYDRANT FROM THE | | | CLOSEST | | | POINT ON THE BUILDING SHALL NOT EXCEED 400 FT (122 M). | | | (2) THE MAXIMUM DISTANCE BETWEEN FIRE HYDRANTS SHALL | | | NOT | | | EXCEED 500 FT (152 M). | | | | | | THE PROPOSED CALCULATED FIRE LAOD AND EXISITNG WATER | | | SUPPLY FROM THE EXISTING HYDRANTS WILL NEED TO BE | | | PROVIDED; HOWEVER, AN ALTERNATIVE 2ND HYDRANT WOULD | | | NEED TO BE IDENTIFIED AS THE S DIXIE LOCATION WOULD NOT | | | BE PRACTICAL FOR FIREFIGHTING OPERATIONS. | | | | | | 9. IF APPLICABLE, PROVIDE FOR A FIRE SPRINKLER AND/OR | | | FIRE ALARM PER THE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND | | | SUBMITTED WITH THE MASTER PLAN. | | | | | | 10. IF APPLICABLE, COMPLETE LIFE SAFETY PLANS SHALL BE | | | PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | 12. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
12-11-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
12-11-2019 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
12-02-2019 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2019-12-11 16:14:34 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: CONNISTON & LAMBERT TOWNHOMES Z19040015 | | | DECEMBER 11, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PROVIDE THE FOLLOWING ITEMS FOR THE TREE | | | DISPOSITION: | | | ? SATISFIED. IDENTIFY AND SHOW THE CORRECT SPECIES OF | | | EACH TREE AND PALM LISTED ON THE DISPOSITION CHART. | | | ? SATISFIED. PROVIDE A SEPARATE TREE DISPOSITION PLAN | | | WITH ALL RELATED DISPOSITION INFORMATION SHOWING | | | LOCATIONS OF EXISTING TREES ON SITE AND SHOW | | | REMOVE/REMAIN OR RELOCATE AND REMOVE THE INFO FROM FROM | | | LANDSCAPE PLAN. | | | ? SATISFIED. GIVE THE CONDITION OF EACH TREE, NOTING | | | THAT ALL NATIVE TREES AND PALMS IN GOOD CONDITION MUST | | | BE PRESERVED OR RELOCATED. | | | STAFF WILL MEET WITH THE APPLICANT TO MAKE CORRECTIONS | | | TO THE TREE DISPOSITION AND MITIGATION CALCULATIONS. | | | APPLICANT HAS NOT MADE THE CHANGES TO PRESERVE OR | | | RELOCATE SABAL PALMS #2, 3, 4, 17, 19, 20, 21, AND 22; | | | LIVE OAK #16, ALL LISTED AS GOOD CONDITION AS REQUIRED. | | | CORRECT NOTE TO REMOVE ?OR MITIGATED?. | | | ? SATISFIED. INCLUDE CANOPY DIAMETER MEASUREMENT FOR | | | TREES IN ORDER TO CALCULATE MITIGATION DUE IF REMOVED. | | | ? SATISFIED. PROVIDE A MITIGATION CHART BASED ON THE | | | PLANT LIST SHOWING THE AMOUNT OF REPLACEMENT TREE | | | CANOPY PROVIDED. | | | | | | 2. SATISFIED. 29 TREES ARE REQUIRED, PALM SUBSTITUTION | | | CANNOT EXCEED 35%. SUGGEST THAT SOME PALMS BE REPLACED | | | WITH SILVER BUTTONWOOD OR EAST PALATKA HOLLY OR SIMILAR | | | TO MAKE THE REQUIRED TREES. JATROPHA CANNOT BE COUNTED | | | AS A TREE. | | | TREES SHOULD BE USED IN THE PLANTING AREAS BETWEEN | | | DRIVEWAY INSTEAD OF PALMS. APPROPRIATE SPECIES SUCH AS | | | GREEN BUTTONWOOD SHOULD BE USED. | | | | | | 3. SATISFIED. SHOW LOCATIONS OF WATER AND SEWER SERVICE | | | LINES ON THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH | | | LANDSCAPING. SEWER LATERALS CAN BE LOCATED TO ALLOW | | | PLANTING OF SMALL TREES RATHER THAN PALMS IN SOME | | | AREAS. DRAINAGE LINES AND YARD DRAIN PLACEMENTS ARE IN | | | CONFLICT WITH THE ROOT SYSTEMS OF THE TREES. | | | WATER AND SEWER LINES ARE NOT SHOWN WHERE THEY CONNECT | | | ACROSS THE FRONT OR REAR YARDS. MUST BE SHOWN TO | | | ESTABLISH THERE ARE NO CONFLICTS WITH APPROVED TREES. | | | EXFILTRATION TO BE SHIFTED AWAY FROM TREES, AND TREES | | | LOCATED TO PROVIDE THE ROOT AREA REQUIRED FOR PROPER | | | GROWTH. | | | 4. SATISFIED. PROVIDE LOCATIONS AND SCREENING FOR ALL | | | ABOVE GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C | | | UNITS, AND IRRIGATION BACKFLOWS. | | | | | | 5. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS | | | REQUIRED TO PROTECT UTILITY LINES AND EXFILTRATION | | | TRENCHES. | | | 6. SATISFIED. PROVIDE INFORMATION ON THE MOISTURE | | | SENSOR AND IRRIGATION SYSTEM OR ADJUST FLORIDA FRIENDLY | | | POINTS TO REMOVE. | | | ADDITIONAL COMMENT 12/4/19: | | | 7. SATISFIED. THE CANOPY MITIGATION FOR EACH TREE | | | REMOVED NEEDS TO BE CORRECTED. SABAL PALMS LISTED AS IN | | | THE ALLEY MUST BE RELOCATED IF IN GOOD CONDITION OR | | | REMOVED AND MITIGATED IF NOT OF SUFFICIENT SIZE TO | | | SURVIVE TRANSPLANTING. | | | REVISED SHEET SUBMITTED. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
07-03-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
07-03-2019 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
07-03-2019 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2019-07-03 16:56:45 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: CONNISTON & LAMBERT TOWNHOMES Z19040015 | | | JULY 3, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PROVIDE THE FOLLOWING ITEMS FOR THE TREE | | | DISPOSITION: | | | ? SATISFIED. IDENTIFY AND SHOW THE CORRECT SPECIES OF | | | EACH TREE AND PALM LISTED ON THE DISPOSITION CHART. | | | ? SATISFIED. PROVIDE A SEPARATE TREE DISPOSITION PLAN | | | WITH ALL RELATED DISPOSITION INFORMATION SHOWING | | | LOCATIONS OF EXISTING TREES ON SITE AND SHOW | | | REMOVE/REMAIN OR RELOCATE AND REMOVE THE INFO FROM FROM | | | LANDSCAPE PLAN. | | | ? PARTIALLY SATISFIED. GIVE THE CONDITION OF EACH TREE, | | | NOTING THAT ALL NATIVE TREES AND PALMS IN GOOD | | | CONDITION MUST BE PRESERVED OR RELOCATED. | | | STAFF WILL MEET WITH THE APPLICANT TO MAKE CORRECTIONS | | | TO THE TREE DISPOSITION AND MITIGATION CALCULATIONS. | | | ? SATISFIED. INCLUDE CANOPY DIAMETER MEASUREMENT FOR | | | TREES IN ORDER TO CALCULATE MITIGATION DUE IF REMOVED. | | | ? SATISFIED. PROVIDE A MITIGATION CHART BASED ON THE | | | PLANT LIST SHOWING THE AMOUNT OF REPLACEMENT TREE | | | CANOPY PROVIDED. | | | | | | 2. PARTIALLY SATISFIED. 29 TREES ARE REQUIRED, PALM | | | SUBSTITUTION CANNOT EXCEED 35%. SUGGEST THAT SOME PALMS | | | BE REPLACED WITH SILVER BUTTONWOOD OR EAST PALATKA | | | HOLLY OR SIMILAR TO MAKE THE REQUIRED TREES. JATROPHA | | | CANNOT BE COUNTED AS A TREE. | | | TREES SHOULD BE USED IN THE PLANTING AREAS BETWEEN | | | DRIVEWAY INSTEAD OF PALMS. APPROPRIATE SPECIES SUCH AS | | | GREEN BUTTONWOOD SHOULD BE USED. | | | | | | 3. PARTIALLY SATISFIED. SHOW LOCATIONS OF WATER AND | | | SEWER SERVICE LINES ON THE LANDSCAPE PLAN AND RESOLVE | | | CONFLICTS WITH LANDSCAPING. SEWER LATERALS CAN BE | | | LOCATED TO ALLOW PLANTING OF SMALL TREES RATHER THAN | | | PALMS IN SOME AREAS. DRAINAGE LINES AND YARD DRAIN | | | PLACEMENTS ARE IN CONFLICT WITH THE ROOT SYSTEMS OF THE | | | TREES. | | | WATER AND SEWER LINES ARE NOT SHOWN WHERE THEY CONNECT | | | ACROSS THE FRONT OR REAR YARDS. MUST BE SHOWN TO | | | ESTABLISH THERE ARE NO CONFLICTS WITH APPROVED TREES. | | | EXFILTRATION TO BE SHIFTED AWAY FROM TREES, AND TREES | | | LOCATED TO PROVIDE THE ROOT AREA REQUIRED FOR PROPER | | | GROWTH. | | | 4. SATISFIED. PROVIDE LOCATIONS AND SCREENING FOR ALL | | | ABOVE GROUND UTILITY VALVES, BACKFLOW PREVENTERS, A/C | | | UNITS, AND IRRIGATION BACKFLOWS. | | | | | | 5. SATISFIED. SHOW LOCATIONS OF ANY ROOT BARRIERS | | | REQUIRED TO PROTECT UTILITY LINES AND EXFILTRATION | | | TRENCHES. | | | 6. SATISFIED. PROVIDE INFORMATION ON THE MOISTURE | | | SENSOR AND IRRIGATION SYSTEM OR ADJUST FLORIDA FRIENDLY | | | POINTS TO REMOVE. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
05-02-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
05-02-2019 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
05-02-2019 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2019-05-02 16:33:36 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: CONNISTON & LAMBERT TOWNHOMES Z19040015 | | | MAY 2, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PROVIDE THE FOLLOWING ITEMS FOR THE TREE | | | DISPOSITION: | | | ? IDENTIFY AND SHOW THE CORRECT SPECIES OF EACH TREE | | | AND PALM LISTED ON THE DISPOSITION CHART. | | | ? PROVIDE A SEPARATE TREE DISPOSITION PLAN WITH ALL | | | RELATED DISPOSITION INFORMATION SHOWING LOCATIONS OF | | | EXISTING TREES ON SITE AND SHOW REMOVE/REMAIN OR | | | RELOCATE AND REMOVE THE INFO FROM FROM LANDSCAPE PLAN. | | | ? GIVE THE CONDITION OF EACH TREE, NOTING THAT ALL | | | NATIVE TREES AND PALMS IN GOOD CONDITION MUST BE | | | PRESERVED OR RELOCATED. | | | ? INCLUDE CANOPY DIAMETER MEASUREMENT FOR TREES IN | | | ORDER TO CALCULATE MITIGATION DUE IF REMOVED. | | | ? PROVIDE A MITIGATION CHART BASED ON THE PLANT LIST | | | SHOWING THE AMOUNT OF REPLACEMENT TREE CANOPY PROVIDED. | | | | | | 2. 29 TREES ARE REQUIRED, PALM SUBSTITUTION CANNOT | | | EXCEED 35%. SUGGEST THAT SOME PALMS BE REPLACED WITH | | | SILVER BUTTONWOOD OR EAST PALATKA HOLLY OR SIMILAR TO | | | MAKE THE REQUIRED TREES. JATROPHA CANNOT BE COUNTED AS | | | A TREE. | | | | | | 3. SHOW LOCATIONS OF WATER AND SEWER SERVICE LINES ON | | | THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH | | | LANDSCAPING. SEWER LATERALS CAN BE LOCATED TO ALLOW | | | PLANTING OF SMALL TREES RATHER THAN PALMS IN SOME | | | AREAS. DRAINAGE LINES AND YARD DRAIN PLACEMENTS ARE IN | | | CONFLICT WITH THE ROOT SYSTEMS OF THE TREES. | | | 4. PROVIDE LOCATIONS AND SCREENING FOR ALL ABOVE GROUND | | | UTILITY VALVES, BACKFLOW PREVENTERS, A/C UNITS, AND | | | IRRIGATION BACKFLOWS. | | | | | | 5. SHOW LOCATIONS OF ANY ROOT BARRIERS REQUIRED TO | | | PROTECT UTILITY LINES AND EXFILTRATION TRENCHES. | | | 6. PROVIDE INFORMATION ON THE MOISTURE SENSOR AND | | | IRRIGATION SYSTEM OR ADJUST FLORIDA FRIENDLY POINTS TO | | | REMOVE. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
P |
Date |
05-03-2019 |
|
|
Cont ID |
|
| Sent By |
|
Date |
05-07-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
05-03-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-05-07 15:34:05 | PUBLIC WORKS HAS NO OBJECTIONS TO THE PROPOSED PROJECT. |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
3 |
Status |
P |
Date |
12-04-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
12-04-2019 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
12-04-2019 |
Time |
16:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
07-01-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
07-01-2019 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
07-01-2019 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2019-07-01 08:27:52 | THE COMMENTS BELOW ARE FROM THE REVIEW OF THE JULY 27, | | | 2019 SUBMITTAL PACKAGE: | | | | | | 1. ON SHEET PD2 ADD THE VERTICAL DATUM REFERENCE AND | | | THE CONVERSION EQUATION TO NGVD1929. ON SHEET PD3 ADD | | | THE CONVERSION EQUATION TO NGVD1929. | | | | | | 2. CONSIDER ADDING ADDITIONAL STEPS BETWEEN GARAGE AND | | | INTERIOR OF UNITS IN ORDER TO FLATTEN DRIVEWAY SLOPES. | | | SOME DRIVEWAYS SLOPES APPEAR TO BE GREATER THAN 14.5%. | | | | | | 3. SHOW THE DRAINAGE AND MAINTENANCE EASEMENTS ON SHEET | | | PD1. | | | | | | 4. THE CURB RAMP ON THE EAST SIDE OF THE ALLEY WILL | | | NEED TO BE CONSTRUCTED TO CURRENT ADA CODES. | | | | | | 5. ENSURE THE SWALES WITHIN THE ALLEY RIGHT OF WAY HAVE | | | POSITIVE DRAINAGE TO CONNISTON ROAD. | | | | | | TRACY L. WARD, P.E. | | | SENOIR STORMWATER ENGINEER | | | ENGINEEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
05-07-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
05-07-2019 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
05-07-2019 |
Time |
18:36 |
Sent To |
|
|
| Notes |
| 2019-05-07 18:36:13 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. THE CITY?S VERTICAL DATUM IS NGVD 1929. THE CITY HAS | | | ALLOWED THE USE OF NAVD 1988 PROVIDED THE CONVERSION | | | EQUATION TO NGVD 1929 IS PROVIDED ON THE SHEET(S). LIST | | | THE CONVERSION EQUATION ON THE ENGINEERING PLANS AND ON | | | THE SURVEY. | | | | | | 2. SHOW THE MILLING AND OVERLAY OF LAMBERT AVE AND THE | | | ALLEY DUE TO ALL OF THE PROPOSED TRENCH CUTS FOR WATER | | | AND SEWER SERVICES. | | | | | | 3. ROOT BARRIERS NEEDED FOR TREES PLANTED ADJACENT TO | | | EXFILTRATION TRENCHES. | | | | | | 4. MASTER DRAINAGE SYSTEM TO BE DESIGNED TO SFWMD | | | CRITERIA, INCLUDING WATER QUALITY TREATMENT AND OFFSITE | | | DISCHARGE. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE A COPY OF THE SFWMD ERP MODIFICATION PRIOR | | | TO STARTING CONSTRUCTION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
P |
Date |
12-05-2019 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
12-05-2019 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
05-07-2019 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
05-07-2019 |
Time |
14:25 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-05-07 14:33:28 | 1. SHOW IMPROVEMENTS ALONG EAST LINE OF ALLEY. | | | 2. REMOVE MEDIAN ENCROACHMENTS INTO ALLEY. | | | 3. ALLEY WILL BE REQUIRED TO BE REPAVED. | | | 4. SEE DEVELOPMENT APPLICATION FOR ENGINEERING | | | CHECKLIST OF ALL ITEMS REQUIRED TO BE SHOWN. | | | 5. CONNECTION LOCATIONS FOR WATER AND SEWER WILL BE | | | DETERMINED AFTER REVIEW OF ALL INFORMATION AND CCTV. | | | 6. SURVEY NEEDS TO SHOW ALL SANITARY AND STORM RIM AND | | | INVERTS ADJACENT TO PROPERTY AND ALL OTHER UTILITIES | | | WITHIN RIGHT-OF-WAY. | | | 7. CITY WILL NOT BE INSTALLING ANY WATER OR SEWER | | | LATERALS. | | | 8. METER LOCATIONS NEED TO BE REFINED. UNCLEAR WHETHER | | | THEY ARE INSIDE PROPERTY OR NOT. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
11-26-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
09-17-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-09-17 12:20:42 | REVISED ON SEPT 18, 2019. | | | | | | PASSED, WITH CONDITIONS: | | | 1. AT THE TIME OF PERMITTING, PLANS SHOULD SHOW CURB | | | CUTS, EDGE OF PAVEMENTS, AND DRIVEWAYS ON THE OPPOSITE | | | SIDE OF ABUTTING ROADWAYS. | | | 2. DIMENSION ALL ABUTTING ROADWAY WIDTH AND THE ALLEY | | | ON THE PLAN AT THE TIME OF PERMITTING. | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
06-28-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-28 15:03:40 | 1. PROVIDE AUTOTURN PATHS FOR ALL POSSIBLE MOVEMENTS OF | | | PASSENGER CARS IN THE GUEST PARKING SPACES. THE | | | AUTOTURN PATHS SHOULD SHOW TWO PASSENGER CARS PARKED | | | SIDE-BY-SIDE AND NOT IMPACT ANY POWER POLE. | | | 2. SHOW CURB CUTS, EDGE OF PAVEMENTS, AND DRIVEWAYS ON | | | THE OPPOSITE SIDE OF CONNISTON ROAD ON THE SITE PLAN. | | | 3. PROVIDE ADA PEDESTRIAN CURB RAMP AT THE NORTHWEST | | | CORNER OF LAMBERT AVENUE AND CONNISTON ROAD, AND ACROSS | | | THE ALLEY ON THE EAST SIDE ON CONNISTON ROAD IN | | | ADDITION TO THE PROPOSED ADA CURB RAMPS CURRENTLY SHOWN | | | ON THE SITE PLAN. | | | 4. DIMENSION THE ROADWAY WIDTH ON LAMBERT AVENUE, | | | CONNISTON ROAD AND THE ALLEY. | | | 5. THE TOWNHOMES SHALL BE RESPONSIBLE TO REPAIR ANY | | | DAMAGED UTILITY POLE CAUSED BY VEHICLES OF RESIDENTS | | | AND THEIR GUESTS TURNING IN/OUT OF THE DRIVEWAYS. | | | 6. PROVIDE UTILITY LETTERS. | | | | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
04-30-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-04-30 17:24:51 | 1. PROVIDE UTILITY LETTERS. | | | 2. THE PROPOSED DEVELOPMENT SHOULD NOT NARROW THE | | | ALLEY. | | | 3. CITY CODE SECTION 94-342 REQUIRES THE ALLEYS TO BE | | | AT LEAST 20 FEET WIDE. ALSO, CITY CODE SECTION | | | 94-485(J) INDICATES THAT IF PARKING STALLS ARE ACCESSED | | | DIRECTLY FROM PUBLIC ALLEY AND EXISTING ALLEY WIDTH | | | DOES NOT COMPLY WITH THE MINIMUM AISLE REQUIREMENTS | | | (WHICH IS 24 FEET FOR 90-DEGREE PARKING), ADDITIONAL | | | PARKING AISLE SHALL BE PROVIDED. | | | 4. REPLACE EXISTING POWER POLES WITH NEW POWER POLES | | | ALONG THE ALLEY. LOCATE THE POWER POLES WITHIN THE | | | PROPERTY AND PROVIDE UTILITY EASEMENT. THIS WILL ALLOW | | | FOR A PAVED ALLEY WIDTH OF 15 FEET FOR VEHICULAR | | | ACCESS. | | | 5. PAVE OR MILL AND RESURFACE THE ALLEY ADJACENT TO THE | | | PROPERTY. | | | 6. PROVIDE AUTOTURN PATHS FOR ALL POSSIBLE MOVEMENTS OF | | | PASSENGER CARS IN THE GUEST PARKING SPACES. THE | | | AUTOTURN PATHS SHOULD SHOW TWO PASSENGER CARS PARKED | | | SIDE-BY-SIDE AND NOT IMPACT ANY POWER POLE. | | | 7. SHOW CURB CUTS, EDGE OF PAVEMENTS, AND DRIVEWAYS ON | | | THE OPPOSITE SIDE OF LAMBERT AVENUE, CONNISTON ROAD AND | | | THE ALLEY ON THE SITE PLAN. | | | 8. INCLUDE PARKING REQUIREMENTS IN THE SITE DATA TABLE | | | ON THE SITE PLAN. | | | 9. PROVIDE ADA PEDESTRIAN CURB RAMP AT THE CORNER OF | | | LAMBERT AVENUE AND CONNISTON ROAD, AND ACROSS THE ALLEY | | | ON CONNISTON ROAD. | | | 10. CONSIDER PROVIDING WIDER SIDEWALK ALONG LAMBERT | | | AVENUE AND CONNISTON ROAD. SIDEWALK SHOULD BE A MINIMUM | | | OF 5 FEET. | | | 11. DIMENSION THE ROADWAY WIDTH ON LAMBERT AVENUE, | | | CONNISTON ROAD AND THE ALLEY. | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | (IN-HOUSE ON TUESDAYS AND WEDNESDAYS) |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
01-14-2020 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
01-14-2020 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
01-14-2020 |
Time |
|
Sent To |
|
|
| Notes |
| 2020-01-14 09:53:50 | CONDITIONS OF APPROVAL: | | | | | | 1.) APPROVAL OF THE MAJOR SUBDIVISION APPLICATION | | | CREATING THE PLAT FOR ELEVEN (11) FEE-SIMPLE TOWNHOUSE | | | LOTS ON THE SUBJECT PROPERTY (REFERENCE: PLANNING BOARD | | | CASE NO. 1823) SHALL BE APPROVED BY THE CITY | | | COMMISSION. THE APPROVED PLAT SHALL BE RECORDED BY THE | | | CLERK OF PALM BACH COUNTY PRIOR TO THE ISSUANCE OF ANY | | | BUILDING PERMIT FOR THE CONSTRUCTION OF THE TOWNHOUSE | | | UNITS. | | | | | | 2.) THE TOWNHOMES SHALL BE RESPONSIBLE FOR MAINTAINING | | | PORTIONS OF CONCRETE CURB ENCROACHING INTO THE ALLEY, | | | AS SHOWN IN THE APPROVED SITE PLAN. | | | | | | 3.) THE TOWNHOMES SHALL BE RESPONSIBLE FOR THE REPAIR | | | OF ANY UTILITY POLES DAMANGED BY THE VEHICLES OF | | | RESIDENTS AND THEIR GUESTS TURNING IN/OUT OF THE | | | DRIVEWAYS. | | | | | | 4.) THE 15-FOOT ALLEY ADJACENT TO THE PROJECT AND | | | LAMBERT AVENUE SHALL BE MILLED AND RESURFACED PRIOR TO | | | THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY (C.O.). | | | | | | 5.) AT THE TIME OF ENGINEERING PERMIT SUBMITTAL, THE | | | CIVIL PLANS SHALL SHOW THE CURB CUTS, EDGE OF PAVEMENTS | | | AND DRIVEWAYS ON THE OPPOSITE SIDE OF THE ABUTTING | | | ROADWAYS. | | | | | | 6.) PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT - PLANNING DIVISION. | | | | | | 7.) ALL PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW | | | CONSTRUCTION OR THE RENOVATION OR IMPROVEMENT OF ANY | | | EXISTING BUILDING, WHERE THE TOTAL CONSTRUCTION COSTS | | | ARE EQUAL TO OR GREATER THAN $750,000 IS SUBJECT TO THE | | | ART IN PUBLIC PLACES REQUIREMENTS OF CHAPTER 78, | | | ARTICLE V, OF THE CITY'S CODE OF ORDINANCES. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
12-09-2019 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
12-09-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
12-09-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-12-09 10:53:35 | *** REVIEW COMMENTS ON THE RESUBMITTAL RECEIVED BY | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION ON | | | 11/20/2019 *** | | | | | | GENERAL COMMENTS: | | | | | | 1.) APPROVAL OF THE SITE PLAN IS CONTINGENT UPON THE | | | APPROVAL OF THE PLAT DOCUMENT (REFERENCE: PB CASE NO. | | | 1823). PLEASE NOTE THAT PLANNING STAFF IS WAITING ON | | | THE APPROVAL OF THE ENGINEERING SERVICES DEPARTMENT TO | | | SCHEDULE THE PLAT FOR CITY COMMISSION. | | | | | | 2.) A MAINTENANCE AGREEMENT FOR THE CURBING WITHIN THE | | | ALLEY RIGHT OF WAY WILL BE REQUIRED PRIOR TO THE | | | ISSUANCE OF A CERTIFICATE OF OCCUPANCY (C.O.). PLEASE | | | CONTACT VINCE NOEL FOR ADDITIONAL INFORMATION. | | | | | | | | | SITE PLAN COMMENTS: | | | | | | 1.) SITE AREA DATA: THE MAXIMUM HEIGHT OF THE BUILDING | | | IS 26'-4" TO THE TOP OF THE PARAPET (NOT 23'-2" AS | | | SPECIFIED IN THE PLAN) | | | | | | 2.) SETBACK INFORMATION: A.) PLEASE REFERENCE THE | | | APPROVAL OF ZBA 3373 FOR THE VARIANCES GRANTED TO THE | | | FRONT SETBACK FOR UNITS 10 AND 11; B.) REMOVE "NORTH" | | | FROM THE SIDE YARD SETBACK REFERENCE; C.) THE MINIMUM | | | PROVIDED SIDE YARD SETBACK SEEMS TO BE 10.05 FT. (NOT | | | 10.37 FT.); D.) REMOVE "CONNISTON" FROM THE FRONT YARD | | | SETBACK REFERENCE. | | | | | | 3.) SETBACK ENCROACHMENTS: A.) THE PROPOSED PATIOS | | | CANNOT BE LOCATED CLOSER THAN 2 FT. FROM THE PROPERTY | | | LINE (NOT THE PORCHES); B.) THE MAXIMUM BALCONY | | | ENCROACHMENT INTO THE REQUIRED SETBACK IS 3 FT. MAX. | | | (NOT 4 FT. MAX. AS SPECIFIED IN THE PLANS). PLEASE | | | CORRECT FOR CONSISTENCY WITH THE ZLDRS. | | | | | | | | | INSTRUCTIONS FOR RESUBMITTAL: | | | | | | * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF EIGHT | | | (8) COPIES, ONE (1) REDUCE COPY IN 11 INCHES X 17 | | | INCHES, AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | * PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS | | | MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
06-28-2019 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
06-28-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
06-27-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-28 10:25:27 | GENERAL COMMENTS: | | | | | | 1.) A REVISED TRAFFIC PERFORMANCE STANDARDS (TPS) | | | REVIEW LETTER FROM THE PALM BEACH COUNTY TRAFFIC | | | DIVISION, REFLECTING CORRECT INFORMATION (I.E. 11 TH | | | UNITS (NOT 12 UNITS) AND OWNERSHIP OF THE LAND) IS | | | REQUIRED. [5/3/2019 REPEAT COMMENT] | | | | | | 2.) THE APPLICATION FOR THE VARIANCE REQUEST TO THE 20 | | | FT. FRONT SETBACK REQUIREMENT IS CURRENTLY PENDING WITH | | | STAFF AND APPROVAL FROM THE ZONING BOARD OF APPEALS | | | (ZBA). PLEASE NOTE THAT SITE PLAN APPROVAL WILL BE | | | CONTINGENT ON THE APPROVAL OF THE VARIANCE REQUEST. | | | (REFERENCE: ZBA CASE NO. 3373) | | | | | | 3.) APPROVAL OF THE SITE PLAN IS CONTINGENT UPON THE | | | APPROVAL OF THE PLAT DOCUMENT (REFERENCE: PB CASE NO. | | | 1823) | | | | | | 4.) A RESOLUTION IS NEEDED FOR THE PLACEMENT OF THE | | | POWER POLES/LIGHT FIXTURES IN THE ALLEY ROW. THE | | | APPLICANT HAS STATED IN THE RESPONSES TO PPRC'S | | | COMMENTS THAT THE "APPLICANT IS WORKING WITH FPL AT | | | THIS TIME TO DETERMINE THE EXTENT OF THE EXISTING POWER | | | POLES CAN BE RELOCATED." PLEASE CONTACT STAFF TO | | | DISCUSS STATUS AND TO DETERMINE IF THE ZBA APPLICATION | | | CAN MOVE FORWARD WHILE THIS ISSUE GETS ADDRESSED. | | | | | | 5.) ANY CHANGES TO THE PLANS (I.E. LANDSCAPE PLAN, SITE | | | PLAN, ARCHITECTURAL PLANS, ETC.) SHALL BE CONSISTENT | | | WITH ALL OTHER PLANS. | | | | | | | | | SITE PLAN COMMENTS: | | | | | | 1.) NOT ALL STRUCTURAL INTRUSIONS HAVE BEEN DIMENSIONED | | | IN THE PLANS (I.E. EYE BROW DETAIL ABOVE THE WINDOWS, | | | OVERHANG ABOVE BALCONY SPACE, ETC.). PLEASE SHOW | | | DIMENSIONS IN THE PLANS TO DEMONSTRATE THAT THE | | | INTRUSIONS DO NOT EXTEND FARTHER THAN 3 FT. INTO A | | | REQUIRED SETBACK. [5/3/19 REPEAT COMMENT] | | | | | | 2.) LANDSCAPE ISLANDS AND BRICK PAVERS AT THE REAR OF | | | THE PROPERTY SHALL BE LOCATED COMPLETELY WITHIN THE | | | BOUNDARIES OF THE SUBJECT PROPERTY AND SHALL NOT | | | ENCROACH INTO THE ALLEY RIGHT-OF-WAY. [5/3/2019 REPEAT | | | COMMENT] | | | | | | 3.) THERE IS A 6 FT. HIGH PVC FENCE LOCATED ALONG THE | | | NORTH PROPERTY LINE OF LOT/UNIT 11. THE FENCE CANNOT | | | EXCEED 4 FT. IN HEIGHT WITHIN THE FIRST 20 FT. OF | | | LAMBERT AVENUE. PLEASE CORRECT/CLARIFY IN THE PLAN. | | | [ZLDR S.94-302(B)(1)] | | | | | | 4.) IS THE FENCE LOCATED ALONG THE SOUTH PROPERTY LINE | | | OF LOT/UNIT 1 4 FT. HIGH OR DOES IT TRANSITIONS TO A | | | DIFFERENT HEIGHT? PLEASE CLARIFY IN THE PLAN. [ZLDR | | | S.94-302(B)(1)] | | | | | | 5.) THE CBU MAIL BOX SHALL BE SETBACK AT LEAST 15 FT | | | FROM THE CENTERLINE OF THE ALLEY TO A GARAGE DOOR | | | FACING THE ALLEY, WHICHEVER IS GREATER. [ZLDR | | | S.94-304(B)(2)] | | | | | | 6.) EXTENDED DRIVEWAY FOR LOT/UNIT 11 SHALL BE SET BACK | | | AT LEAST 3 FT. FROM THE REAR PROPERTY LINE. [ZLDR | | | S.94-482(D)(1)] | | | | | | 7.) THE SITE LOCATION MAP DOES NOT ACCURATELY REFLECT | | | THE LOCATION OF THE SUBJECT SITE. PLEASE CORRECT. | | | | | | 8.) PLEASE ADDRESS THE FOLLOWING IN THE SETBACK | | | INFORMATION TABLE: PROVIDED FRONT YARD: 12.5 FT. MIN. | | | (NOT 20.10); WHERE DID THE CORNER YARD REQUIREMENT | | | INFORMATION COME FROM? THE INFORMATION SHOULD BE | | | REMOVED FROM THE TABLE IF NOT APPLICABLE. | | | | | | 9.) PLEASE CLARIFY THE PORCH SETBACK ENCROACHMENT | | | INFORMATION IN THE SETBACK ENCROACHMENTS TABLE, AS IT | | | IS NOT CLEAR TO STAFF. | | | | | | 10.) IN THE ZONING AND LAND USE INFORMATION TABLE: | | | ELIMINATE THE REFERENCE TO 15.43 DU/AC; PLEASE CHECK | | | THE CALCULATIONS FOR TOTAL GROSS BUILDING SF AND FAR. | | | CALCULATIONS DO NOT SEEM TO ADD UP WITH THE | | | CALCULATIONS PROVIDED IN THE ARCHITECTURAL DRAWINGS. | | | | | | | | | LANDSCAPE PLAN: | | | | | | 1.) PROVIDE ORIGINAL SIGNED AND SEALED PLANS. COPIES DO | | | NOT SUFFICE. | | | | | | | | | INSTRUCTIONS FOR RESUBMITTAL: | | | | | | * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF | | | FIFTEEN (15) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 | | | INCHES X 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 | | | INCHES, AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | * PLEASE NOTE THAT THE CHANGES ON THE RESUBMITTED PLANS | | | MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
05-03-2019 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
05-03-2019 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
05-03-2019 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2019-05-03 15:39:46 | GENERAL COMMENTS: | | | | | | 1.) A REVISED TRAFFIC PERFORMANCE REVIEW (TPS) LETTER | | | FROM THE PALM BEACH COUNTY TRAFFIC DIVISION, REFLECTING | | | CORRECT INFORMATION (I.E. 11 TH UNITS (NOT 12 TH UNITS) | | | AND OWNERSHIP OF THE LAND) IS REQUIRED. | | | | | | 2.) A PROPERTY OWNERS ASSOCIATION SHALL BE ESTABLISHED | | | TO PROVIDE FOR THE MAINTENANCE OF THE PROPOSED COMMON | | | AREA, LOCATED ON LOTS 6 AND 7 AND ANY OTHER COMMON | | | FEATURES (I.E. SIGNAGE). [ZLDR S.94-309(G)(3)] | | | | | | 3.) ALL NEW LIGHT FIXTURES PROPOSED WITHIN THE | | | RIGHT-OF-WAY SHALL BE APPROVED BY THE CITY?S | | | ENGINEERING DEPARTMENT. | | | | | | SITE PLAN COMMENTS: | | | | | | 1.) EACH LOT SHALL BE A MINIMUM OF 16 FT. WIDE. PLEASE | | | PROVIDE DIMENSIONS TO DEMONSTRATE COMPLIANCE. [ZLDR | | | S.94-309(G)(6)(B)] | | | | | | 2.) A MINIMUM FRONT SETBACK OF 20 FT. IS REQUIRED FOR | | | THE UNITS. PLAN SHOWS A MINIMUM FRONT SETBACK OF 6.67 | | | FT.). A VARIANCE TO THE FRONT SETBACK WILL BE REQUIRED. | | | THE VARIANCE CAN ONLY BE GRANTED BY THE ZONING BOARD OF | | | APPEALS (ZBA). [ZLDR S.94-309(G)(6)(D.)(1)] (NOTE: A | | | ZBA APPLICATION FOR THE VARIANCE REQUEST WAS SUBMITTED | | | ON 4/9/2019. STAFF WILL SCHEDULE THE APPLICATION FOR A | | | MEETING WITH THE ZBA ONCE THE SITE PLAN HAS BEEN DEEMED | | | SUFFICIENT.) | | | | | | 3.) WHAT IS THE LOT DEPTH OF LOT/UNIT #9? SHOW | | | DIMENSIONS TO DEMONSTRATE THAT THE REAR SETBACK IS IN | | | COMPLIANCE WITH ZLDR S.94-309(G)(6)(D.)(3.). THE | | | MINIMUM REAR SETBACK MUST BE 15 FT. OR 10 PERCENT OF | | | THE LOT DEPTH, WHICHEVER IS LESS. | | | | | | 4.) THE FENCE LOCATED WITHIN THE FRONT SETBACK (THE | | | AREA WITHIN THE FIRST 20 FT. OF LAMBERT AVENUE) SHALL | | | NOT EXCEED 4 FT. IN HEIGHT. THE PLANS SHOW A 5 FT. TALL | | | ALUMINUM PICKET FENCE WITHIN THE FRONT SETBACK AREA. | | | PLEASE ADDRESS. [ZLDR S.94-302(B)] | | | | | | 5.) BALCONIES AND OTHER STRUCTURAL INTRUSIONS SHALL NOT | | | EXTEND FARTHER THAN 3 FT. INTO ANY REQUIRED SETBACK. | | | PLEASE SHOW DIMENSIONS TO DEMONSTRATE COMPLIANCE. [ZLDR | | | S.94-305(B)(2)] | | | | | | 6.) AWNINGS SHALL NOT PROJECT MORE THAN 4 FT. INTO A | | | REQUIRED SETBACK. SHOW DIMENSIONS TO DEMONSTRATE | | | COMPLIANCE. [ZLDR S.94-305(B)(5)] | | | | | | 7.) SHOW SETBACK DIMENSIONS FOR THE LOCATION OF THE | | | PROPOSED PATIOS TO THE PROPERTY LINES. LOCATION OF THE | | | PATIO SHALL BE IN COMPLIANCE WITH THE SETBACK | | | REQUIREMENT OF ZLDR S.94-305(B)(7)]. | | | | | | 8.) SHOW THE REQUIRED SITE VISIBILITY TRIANGLE AT THE | | | CORNER OF CONNISTON ROAD AND THE PUBLIC ALLEY TO ENSURE | | | THAT NO PROPOSED STRUCTURES AND/OR VEGETATION WILL | | | IMPACT THE LINE OF SIGHT. [ZLDR S.94-305(E)] | | | | | | 9.) ALL PROPOSED OUTDOOR LIGHTING (I.E. SECURITY | | | LIGHTS, BOLLARD LIGHTS, ETC.) SHALL BE SHIELDED TO | | | REDUCE GLARE AND SHALL BE ARRANGED TO REFLECT LIGHT OR | | | GLARE AWAY FROM ALL ADJACENT RESIDENTIAL DISTRICTS, | | | ADJACENT RESIDENCES, OR PUBLIC THOROUGHFARES. A NOTE | | | SHALL BE PROVIDED IN THE PLANS TO DEMONSTRATE | | | COMPLIANCE. [ZLDR S.94-309(A.)] | | | | | | 10.) MECHANICAL EQUIPMENT (A/C PAD/UNITS) CANNOT | | | ENCROACH MORE THAN 4 FT. INTO A SETBACK. PLEASE SHOW | | | SETBACK DIMENSIONS TO DEMONSTRATE COMPLIANCE. [ZLDR | | | S.94-305(A)(4)] | | | | | | 11.) LANDSCAPE ISLANDS AND BRICK PAVERS AT THE REAR OF | | | THE PROPERTY SHALL BE LOCATED COMPLETELY WITHIN THE | | | BOUNDARIES OF THE SUBJECT PROPERTY AND SHALL NOT | | | ENCROACH INTO THE ALLEY RIGHT-OF-WAY. | | | | | | ARCHITECTURAL (FLOOR PLAN AND ELEVATIONS): | | | | | | 1.) PLEASE PROVIDE CALCULATIONS TO DEMONSTRATE THAT | | | EACH UNIT WILL MEET THE MINIMUM UNIT REQUIREMENT OF | | | 2,150 SQ. FT. [ZLDR S.94-76(A)(1)(I)] | | | | | | 2.) PLEASE PROVIDE HEIGHT OF THE BUILDING FROM GRADE TO | | | THE HIGHEST POINT OF THE STRUCTURE (INCLUDING TO THE | | | TOP OF THE PARAPET). PER ZLDR S.94-309(G)(6)(C.), THE | | | BUILDING CANNOT EXCEED A HEIGHT OF 35 FT. | | | | | | 3.) THE MINIMUM NET FLOOR AREA, EXCLUDING ATTIC, GARAGE | | | AND UTILITY AREAS SHALL BE A MINIMUM OF 900 SQ. FT. | | | PLEASE SHOW CALCULATIONS TO DEMONSTRATE COMPLIANCE. | | | [ZLDR S.94-309(G)(6.)(F.)] | | | | | | 4.) SHOW DEPTH OF THE GARAGES TO DEMONSTRATE THAT THE | | | GARAGES CAN ACCOMMODATE VEHICLES. | | | | | | SIGNAGE: | | | | | | 1.) DETAILS ON THE PROPOSED SIGNAGE LOCATED AT THE | | | SOUTHEAST CORNER OF THE PROJECT SITE HAS NOT BEEN | | | PROVIDED. REQUIRED DETAILS INCLUDE SETBACK DIMENSIONS | | | FROM THE PROPERTY LINES, DIMENSIONS OF THE PROPOSED | | | SIGNAGE, SIGN AREA CALCULATIONS, ETC. | | | | | | 2.) CONSIDER ELIMINATING THE PROPOSED SIGNAGE AT THE | | | SOUTHEAST CORNER OF THE PROJECT SITE, AS STAFF BELIEVES | | | THE SIGNAGE IS UNNECESSARY FOR THE PROJECT. | | | | | | OTHER SUGGESTED IMPROVEMENTS: | | | | | | 1.) CONSIDER MAKING UNIT #11 SMALLER TO FIT THE | | | BUILDING ON THE LOT BETTER. | | | | | | 2.) WHERE WILL BE POWER POLE(S)/LINES BE RELOCATED? IT | | | IS RECOMMENDED THAT THE APPLICANT CONSIDER RELOCATING | | | OVERHEAD LINES UNDERGROUND AT THE REAR OF THE PROPERTY. | | | | | | INSTRUCTIONS FOR RESUBMITTAL: | | | | | | * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX | | | (6) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 INCHES X | | | 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 INCHES, AND | | | AN ELECTRONIC COPY OF ALL PLANS. | | | | | | * PLEASE NOTE THAT CHANGES ON THE RESUBMITTED PLANS MAY | | | RESULT IN ADDITIONAL COMMENTS. | | | | | | * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE. | | | |
|
|
| |