| Plan Review Stops For Project Z19010011 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
02-12-2019 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
02-12-2019 |
Time |
20:35 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
02-12-2019 |
Time |
20:35 |
Sent To |
|
|
| Notes |
| 2019-02-12 20:39:22 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. ACCESSIBLE ROUTE FOR PEDESTRIANS AND WHEELCHAIR | | | USERS. THE SITE PLAN, SHEET 5 OF 6 SHOWS ONLY VEHICULAR | | | ACCESS TO THE BUILDING. WHEN SUBMITTED FOR PERMIT, THE | | | PLANS SHALL SHOW AT LEAST ONE ACCESSIBLE ROUTE, | | | COMPLYING WITH SECTIONS 206.2 AND 402.2 OF FLORIDA | | | ACCESSIBILITY CODE, FROM THE PUBLIC RIGHT-OF-WAY TO ALL | | | ACCESSIBLE BUILDING OR FACILITY ENTRANCES. | | | | | | 3. ANY PART OF THE ABOVE-MENTIONED ACCESSIBLE ROUTE | | | WITH A SLOPE GREATER THAN 1:20 SHALL BE CONSIDERED A | | | RAMP AND SHALL COMPLY WITH SECTION 405 OF FLORIDA | | | ACCESSIBILITY CODE. | | | | | | 4. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 5. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT | | | MICHAEL ORIO, GIS SUPPORT SPECIALIST, AT (561) 494 | | | 1080, OR BY EMAIL: [email protected] | | | | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
06-11-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
06-11-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
06-11-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-11 13:56:07 | SHEET 15: | | | | | | CORRECT NOTES REFERRING TO SHEET C500 SERIES. | | | | | | AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | | | | PROVIDE EASEMENT FOR WATER METER. | | | | | | LABEL MAIN WATER SERVICE SIZE, MATERIAL, MAINTAINING | | | AGENCY. | | | | | | SHOW VERTICAL DATUM AND DATUM CONVERSION INFORMATION | | | (NAVD 88 AND NGVD 29). | | | | | | THERE ARE WATER AND SEWER LINES IN THE VICINITY OF THIS | | | PROJECT. PER CHAPTER 556 OF THE FLORIDA STATE STATUTES, | | | YOU MUST CALL 811 FOR UTILITY LOCATES AT LEAST TWO FULL | | | BUSINESS DAYS IN ADVANCE OF ANY CONSTRUCTION OR | | | DEMOLITION WORK. MORE INFORMATION CAN BE FOUND HERE: | | | HTTP://WWW.SUNSHINE811.COM/ | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
02-08-2019 |
|
|
Cont ID |
|
| Sent By |
RRossano |
Date |
02-08-2019 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
02-08-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-02-08 11:45:30 | 1) PLEASE PROVIDE CALCULATIONS OF EXISTING AND PROPOSED | | | DEMANDS FOR WATER & SEWER (AVERAGE, MAXIMUM AND PEAK) | | | AND FIRE FLOW DEMANDS. CALCULATIONS SHALL BE PER FAC | | | 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | 2) PLEASE PROVIDE MORE DETAIL ON WATER & SEWER | | | CONNECTIONS - SHOW PROPOSED LOCATIONS AND DIMENSIONS OF | | | ALL WATER, STORMWATER, AND SANITARY AND SEWER LINES, | | | INCLUDING STUBS TO EACH PROPERTY LINE FOR WATER AND | | | SANITARY SEWERS, THE MAKE AND MODEL OF ALL VALVES, | | | METERS, AND OTHERS DEVICES TO BE INSTALLED ON THE | | | SYSTEM, CATCH BASINS, CULVERTS, DITCHES INCLUDING | | | GRADES, PIPES SIZES, MATERIALS, ELEVATIONS, | | | ASSUMPTIONS, CALCULATIONS, INVERT ELEVATIONS FOR ALL | | | INLETS AND MANHOLES AND PROFILES OF SANITARY SEWER | | | LINES. ALL AVAILABLE ELEVATION SHALL BE SHOWN ON THE | | | PROFILE VIEW. DIRECTION OF FLOW SHALL BE SHOWN ON PLAN | | | VIEW ON PLAN VIEW FOR ALL SANITARY AND STORM SEWERS. | | | ADDITIONALLY, PLAN VIEW SHALL SHOW ALL EXISTING AND | | | PROPOSED UNDERGROUND UTILITY LAYOUT, INCLUDING FIBER | | | OPTIC, ELECTRIC, GAS, AND CABLEVISION & | | | TELECOMMUNICATION FACILITIES LOCATED ON THE | | | RIGHT-OF-WAY. | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | | | | RICK ROSSANO | | | PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1098 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 246-9525 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
01-29-2019 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
01-29-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
01-28-2019 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2019-01-29 08:58:16 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | | | | 1) THE INSTALLATION OF THE TRAILERS SHALL MEET THE | | | REQUIREMENTS OF THE FLORIDA FIRE PREVENTION CODE, 6TH | | | EDITION AND ALL OTHER APPLICABLE CODES. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
P |
Date |
08-27-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
08-27-2019 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
08-27-2019 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2019-08-27 16:21:42 | PROJECT: TEMPORARY FIRE STATION NO. 9 Z19010011 | | | AUGUST 27, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. SATISFIED. SHOW THE REQUIRED OPEN SPACE OF 40 | | | PERCENT OF THE AFFECTED AREA OF THE SITE, AND CALCULATE | | | REQUIRED TREES AND FLOWERING TREES TO CURRENT CODE OF 1 | | | TREE PER 1500 SQ FT OF REQUIRED OPEN SPACE OR PORTION | | | THEREOF, AND FLOWERING TREES TO ONE PER 6000 SQ FT OR | | | PORTION THEREOF PER SECTION 94-442(C)(2) B. | | | 40% OF AFFECTED AREA IS 24433 SQ FT. RECALCULATE | | | REQUIRED TREES, FLOWERING TREES, AND SHRUBS. | | | REPEAT COMMENT, CALCULATIONS WERE NOT CHANGED. | | | | | | 2. PREVIOUSLY SATISFIED. | | | | | | 3. PREVIOUSLY SATISFIED. | | | | | | 4. PREVIOUSLY SATISFIED. | | | | | | 5. SATISFIED. PROVIDE THE PERVIOUS LANDSCAPE AREA | | | SQUARE FOOTAGE ON THE LANDSCAPE PLAN FOR THE AFFECTED | | | AREA. | | | | | | 6. SATISFIED. PROVIDE FLORIDA FRIENDLY LANDSCAPE POINTS | | | TO SHOW CURRENT APPLICABLE CODE REQUIRES 50 POINTS PER | | | SECTION 94-442(G) WITHOUT DOUBLE COUNTING PLANTS IN THE | | | SAME CATEGORY. | | | CORRECT MULCH POINTS TO 5 PER CURRENT CODE. | | | REPEAT COMMENT POINTS WERE NOT CORRECTED. | | | | | | 7. SATISFIED. | | | | | | 8. SATISFIED. | | | | | | 9. SATISFIED. | | | | | | 10. SATISFIED. | | | ADDITIONAL COMMENTS 6/12/19: | | | 11. THE TREE DISPOSITION LIST MUST BE COMPLETED AND | | | CORRECTED FOR THE FOLLOWING: | | | ? SATISFIED. PROVIDE CANOPY MITIGATION SQUARE FOOTAGE | | | REQUIRED FOR ALL REMOVED TREES EXCEPT INVASIVE EXOTIC | | | SPECIES. TREES AND PALMS CANOPY SQUARE FOOTAGE TO BE | | | MITIGATED BASED ON CATEGORY. ANY TREES 20 FEET OR MORE | | | CANOPY DIAMETER TO BE MITIGATED BY ACTUAL SQUARE | | | FOOTAGE. | | | ? SATISFIED. IDENTIFY SPECIES LISTED AS UNKNOWN. | | | IDENTIFY PALM SPECIES. | | | ? SATISFIED. PROVIDE THE MITIGATION VALUES BY CATEGORY | | | FOR THE PROPOSED TREES AND PALMS. | | | 12. SATISFIED. STAFF HAS BEEN NOTIFIED THAT THERE MAY | | | BE PROTECTED SPECIES WITHIN THE DESIGNATED AREA OF | | | DEVELOPMENT. STAFF WILL FOLLOW UP TO SEE IF ANY FURTHER | | | ENVIRONMENTAL ASSESSMENT IS REQUIRED. | | | | | | 13. SATISFIED. SHOW THE CLEARING AREA FOR THE SEWAGE | | | LINE ON THE LANDSCAPE PLAN AS IT RUNS NORTH ACROSS THE | | | REST OF THE PROPERTY AND ADD ANY TREES TO THE | | | DISPOSITION THAT HAVE TO BE REMOVED. | | | ADDITIONAL COMMENTS 8/7/19: | | | 14. SATISFIED. INDICATE AREAS OF SOD AND IDENTIFY THE | | | SPECIES TO BE INSTALLED. | | | | | | 15. SATISFIED. REVISE THE TREE DISPOSITION PLAN TO | | | IDENTIFY REMOVALS WITH AN X. | | | | | | 16. SATISFIED. EXPLAIN THE REASON FOR NOT RELOCATING | | | THE SABAL PALMS. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
08-07-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
08-07-2019 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
08-07-2019 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2019-08-07 12:27:26 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: TEMPORARY FIRE STATION NO. 9 Z19010011 | | | AUGUST 7, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. NOT SATISFIED. SHOW THE REQUIRED OPEN SPACE OF 40 | | | PERCENT OF THE AFFECTED AREA OF THE SITE, AND CALCULATE | | | REQUIRED TREES AND FLOWERING TREES TO CURRENT CODE OF 1 | | | TREE PER 1500 SQ FT OF REQUIRED OPEN SPACE OR PORTION | | | THEREOF, AND FLOWERING TREES TO ONE PER 6000 SQ FT OR | | | PORTION THEREOF PER SECTION 94-442(C)(2) B. | | | 40% OF AFFECTED AREA IS 24433 SQ FT. RECALCULATE | | | REQUIRED TREES, FLOWERING TREES, AND SHRUBS. | | | REPEAT COMMENT, CALCULATIONS WERE NOT CHANGED. | | | | | | 2. PREVIOUSLY SATISFIED. | | | | | | 3. PREVIOUSLY SATISFIED. | | | | | | 4. PREVIOUSLY SATISFIED. | | | | | | 5. SATISFIED. PROVIDE THE PERVIOUS LANDSCAPE AREA | | | SQUARE FOOTAGE ON THE LANDSCAPE PLAN FOR THE AFFECTED | | | AREA. | | | | | | 6. PARTIALLY SATISFIED. PROVIDE FLORIDA FRIENDLY | | | LANDSCAPE POINTS TO SHOW CURRENT APPLICABLE CODE | | | REQUIRES 50 POINTS PER SECTION 94-442(G) WITHOUT DOUBLE | | | COUNTING PLANTS IN THE SAME CATEGORY. | | | CORRECT MULCH POINTS TO 5 PER CURRENT CODE. | | | REPEAT COMMENT POINTS WERE NOT CORRECTED. | | | | | | 7. SATISFIED. | | | | | | 8. SATISFIED. | | | | | | 9. SATISFIED. | | | | | | 10. SATISFIED. | | | ADDITIONAL COMMENTS 6/12/19: | | | 11. THE TREE DISPOSITION LIST MUST BE COMPLETED AND | | | CORRECTED FOR THE FOLLOWING: | | | ? SATISFIED. PROVIDE CANOPY MITIGATION SQUARE FOOTAGE | | | REQUIRED FOR ALL REMOVED TREES EXCEPT INVASIVE EXOTIC | | | SPECIES. TREES AND PALMS CANOPY SQUARE FOOTAGE TO BE | | | MITIGATED BASED ON CATEGORY. ANY TREES 20 FEET OR MORE | | | CANOPY DIAMETER TO BE MITIGATED BY ACTUAL SQUARE | | | FOOTAGE. | | | ? SATISFIED. IDENTIFY SPECIES LISTED AS UNKNOWN. | | | IDENTIFY PALM SPECIES. | | | ? SATISFIED. PROVIDE THE MITIGATION VALUES BY CATEGORY | | | FOR THE PROPOSED TREES AND PALMS. | | | 12. SATISFIED. STAFF HAS BEEN NOTIFIED THAT THERE MAY | | | BE PROTECTED SPECIES WITHIN THE DESIGNATED AREA OF | | | DEVELOPMENT. STAFF WILL FOLLOW UP TO SEE IF ANY FURTHER | | | ENVIRONMENTAL ASSESSMENT IS REQUIRED. | | | | | | 13. SATISFIED. SHOW THE CLEARING AREA FOR THE SEWAGE | | | LINE ON THE LANDSCAPE PLAN AS IT RUNS NORTH ACROSS THE | | | REST OF THE PROPERTY AND ADD ANY TREES TO THE | | | DISPOSITION THAT HAVE TO BE REMOVED. | | | ADDITIONAL COMMENTS 8/7/19: | | | 14. INDICATE AREAS OF SOD AND IDENTIFY THE SPECIES TO | | | BE INSTALLED. | | | | | | 15. REVISE THE TREE DISPOSITION PLAN TO IDENTIFY | | | REMOVALS WITH AN X. | | | | | | 16. EXPLAIN THE REASON FOR NOT RELOCATING THE SABAL | | | PALMS. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
06-12-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
06-12-2019 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
06-12-2019 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2019-06-12 10:57:42 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: TEMPORARY FIRE STATION NO. 9 Z19010011 | | | JUNE 12, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. NOT SATISFIED. SHOW THE REQUIRED OPEN SPACE OF 40 | | | PERCENT OF THE AFFECTED AREA OF THE SITE, AND CALCULATE | | | REQUIRED TREES AND FLOWERING TREES TO CURRENT CODE OF 1 | | | TREE PER 1500 SQ FT OF REQUIRED OPEN SPACE OR PORTION | | | THEREOF, AND FLOWERING TREES TO ONE PER 6000 SQ FT OR | | | PORTION THEREOF PER SECTION 94-442(C)(2) B. | | | 40% OF AFFECTED AREA IS 24433 SQ FT. RECALCULATE | | | REQUIRED TREES, FLOWERING TREES, AND SHRUBS. | | | | | | 2. SATISFIED. LIGUSTRUM AND EUROPEAN FAN PALM DO NOT | | | MEET CITY POLICY TO CHOOSE A FLORIDA NATIVE SPECIES | | | WHEN POSSIBLE. CHANGE TO A NATIVE SPECIES. | | | | | | 3. SATISFIED. SHOW AND LABEL THE REQUIRED 5 FOOT | | | LANDSCAPE BUFFER ON THE WEST AND SOUTH ADJACENT TO THE | | | PROPERTY LINES ON THE SITE AND LANDSCAPE PLANS. PROVIDE | | | THE BUFFER REQUIREMENTS AND CALCULATIONS ON THE PLAN. | | | ONE TREE PER 30 LF OR PORTION THEREOF IS REQUIRED. | | | LARGER TREE SPECIES MUST BE USED WHERE POSSIBLE TO | | | PROVIDE BUFFERING TO ADJACENT PROPERTIES AND PROVIDE | | | SHADE FOR PARKING AREAS. | | | | | | 4. NOT SATISFIED. ADD A COLUMN FOR DROUGHT TOLERANCE TO | | | THE PLANT LIST AND PROVIDE THE LEVEL FOR EACH SPECIES. | | | | | | 5. NOT SATISFIED. PROVIDE THE PERVIOUS LANDSCAPE AREA | | | SQUARE FOOTAGE ON THE LANDSCAPE PLAN FOR THE AFFECTED | | | AREA. | | | | | | 6. PARTIALLY SATISFIED. PROVIDE FLORIDA FRIENDLY | | | LANDSCAPE POINTS TO SHOW CURRENT APPLICABLE CODE | | | REQUIRES 50 POINTS PER SECTION 94-442(G) WITHOUT DOUBLE | | | COUNTING PLANTS IN THE SAME CATEGORY. | | | CORRECT MULCH POINTS TO 5 PER CURRENT CODE. | | | | | | | | | 7. SATISFIED. SHOW CALCULATIONS FOR THE BUILDING FOR | | | COMPLIANCE WITH 30 PERCENT PERIMETER LANDSCAPE PER | | | SECTION 94-443(E)(1). | | | | | | 8. SATISFIED. SHOW THE CLEARING AREA FOR THE SEWAGE | | | LINE ON THE LANDSCAPE PLAN AS IT RUNS NORTH ACROSS THE | | | REST OF THE PROPERTY AND ADD ANY TREES TO THE | | | DISPOSITION THAT HAVE TO BE REMOVED. | | | | | | 9. SATISFIED. PROVIDE THE LOCATIONS OF LIGHTING ON THE | | | LANDSCAPE PLAN TO PREVENT CONFLICTS WITH TREES. | | | | | | 10. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | ADDITIONAL COMMENTS 6/12/19: | | | 11. THE TREE DISPOSITION LIST MUST BE COMPLETED AND | | | CORRECTED FOR THE FOLLOWING: | | | ? PROVIDE CANOPY MITIGATION SQUARE FOOTAGE REQUIRED FOR | | | ALL REMOVED TREES EXCEPT INVASIVE EXOTIC SPECIES. TREES | | | AND PALMS CANOPY SQUARE FOOTAGE TO BE MITIGATED BASED | | | ON CATEGORY. ANY TREES 20 FEET OR MORE CANOPY DIAMETER | | | TO BE MITIGATED BY ACTUAL SQUARE FOOTAGE. | | | ? IDENTIFY SPECIES LISTED AS UNKNOWN. IDENTIFY PALM | | | SPECIES. | | | ? PROVIDE THE MITIGATION VALUES BY CATEGORY FOR THE | | | PROPOSED TREES AND PALMS. | | | 12. STAFF HAS BEEN NOTIFIED THAT THERE MAY BE PROTECTED | | | SPECIES WITHIN THE DESIGNATED AREA OF DEVELOPMENT. | | | STAFF WILL FOLLOW UP TO SEE IF ANY FURTHER | | | ENVIRONMENTAL ASSESSMENT IS REQUIRED. | | | | | | 13. SHOW THE CLEARING AREA FOR THE SEWAGE LINE ON THE | | | LANDSCAPE PLAN AS IT RUNS NORTH ACROSS THE REST OF THE | | | PROPERTY AND ADD ANY TREES TO THE DISPOSITION THAT HAVE | | | TO BE REMOVED. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
02-11-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
02-11-2019 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
02-11-2019 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2019-02-11 16:53:50 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: TEMPORARY FIRE STATION NO. 9 Z19010011 | | | FEBRUARY 11, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | | | | 1. SHOW THE REQUIRED OPEN SPACE OF 40 PERCENT OF THE | | | AFFECTED AREA OF THE SITE, AND CALCULATE REQUIRED TREES | | | AND FLOWERING TREES TO CURRENT CODE OF 1 TREE PER 1500 | | | SQ FT OF REQUIRED OPEN SPACE OR PORTION THEREOF, AND | | | FLOWERING TREES TO ONE PER 6000 SQ FT OR PORTION | | | THEREOF PER SECTION 94-442(C)(2) B. | | | | | | 2. LIGUSTRUM AND EUROPEAN FAN PALM DO NOT MEET CITY | | | POLICY TO CHOOSE A FLORIDA NATIVE SPECIES WHEN | | | POSSIBLE. CHANGE TO A NATIVE SPECIES. | | | | | | 3. SHOW AND LABEL THE REQUIRED 5 FOOT LANDSCAPE BUFFER | | | ON THE WEST AND SOUTH ADJACENT TO THE PROPERTY LINES ON | | | THE SITE AND LANDSCAPE PLANS. PROVIDE THE BUFFER | | | REQUIREMENTS AND CALCULATIONS ON THE PLAN. ONE TREE PER | | | 30 LF OR PORTION THEREOF IS REQUIRED. LARGER TREE | | | SPECIES MUST BE USED WHERE POSSIBLE TO PROVIDE | | | BUFFERING TO ADJACENT PROPERTIES AND PROVIDE SHADE FOR | | | PARKING AREAS. | | | | | | 4. ADD A COLUMN FOR DROUGHT TOLERANCE TO THE PLANT LIST | | | AND PROVIDE THE LEVEL FOR EACH SPECIES. | | | | | | 5. PROVIDE THE PERVIOUS LANDSCAPE AREA SQUARE FOOTAGE | | | ON THE LANDSCAPE PLAN FOR THE AFFECTED AREA. | | | | | | 6. PROVIDE FLORIDA FRIENDLY LANDSCAPE POINTS TO SHOW | | | CURRENT APPLICABLE CODE REQUIRES 50 POINTS PER SECTION | | | 94-442(G) WITHOUT DOUBLE COUNTING PLANTS IN THE SAME | | | CATEGORY. | | | | | | | | | 7. SHOW CALCULATIONS FOR THE BUILDING FOR COMPLIANCE | | | WITH 30 PERCENT PERIMETER LANDSCAPE PER SECTION | | | 94-443(E)(1). | | | | | | 8. SHOW THE CLEARING AREA FOR THE SEWAGE LINE ON THE | | | LANDSCAPE PLAN AS IT RUNS NORTH ACROSS THE REST OF THE | | | PROPERTY AND ADD ANY TREES TO THE DISPOSITION THAT HAVE | | | TO BE REMOVED. | | | | | | | | | | | | | | | 9. PROVIDE THE LOCATIONS OF LIGHTING ON THE LANDSCAPE | | | PLAN TO PREVENT CONFLICTS WITH TREES. | | | | | | 10. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | | LANDSCAPES. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
3 |
Status |
P |
Date |
08-28-2019 |
|
|
Cont ID |
|
| Sent By |
|
Date |
08-28-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
08-28-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-28 14:42:10 | NO FURTHER COMMENTS. | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
F |
Date |
08-05-2019 |
|
|
Cont ID |
|
| Sent By |
|
Date |
08-05-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
08-05-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-08-05 07:32:50 | THE DUMPSTER ENCLUSURE DETAILS (N.S.T) PRENSETED ON THE | | | SHEET C501 IS OBSOLETE AND NOT TO THE LATEST SPEC. | | | (GC-8, REVISED JUNE 2019) ATTACHED. | | | | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
02-09-2019 |
|
|
Cont ID |
|
| Sent By |
|
Date |
06-12-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
06-12-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-12 11:10:25 | PLEASE PROVIDE A PLAN SHOWING AUTO-TURN FOR SANITATION | | | SERVICE ALONG WITH THE DUMPSTER ENCLOSURE SPEC. | | | | | | MATT HEJAZI | | | DEPT. OF PUBLIC WORKS | | | [email protected] | | | 561-822-2045 | | 2019-02-09 19:15:57 | DID NOT SEE ANY PLANS FOR SANITATION SERVICE. PLEASE | | | ADD PLANS BASED ON STANDARDS. |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
4 |
Status |
P |
Date |
08-28-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
08-28-2019 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
08-28-2019 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2019-08-28 12:18:41 | THE COMMENTS BELOW ARE FROM THE REVIEW OF THE AUGUST | | | 26, 2019 ROUTED SUBMITTAL PACKAGE: | | | | | | 1. BALD CYPRESS TREE PROPOSED OVER STORM PIPE LEAVING | | | THE STORMWATER MANAGEMENT FACILITY (SHEET L101, 23 OF | | | 35). | | | | | | 2. CONSIDER ADDING ROOT BARRIER FOR THE ORANGE GEIGER | | | TREES ON EITHER SIDE OF THE STORM PIPE BETWEEN THE | | | GRASS ISLAND AND THE STORMWATER MANAGEMENT FACILITY | | | (SHEET L101, 23 OF 35). | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
3 |
Status |
P |
Date |
08-01-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
08-01-2019 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
08-01-2019 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2019-08-01 10:39:46 | THE FOLLOWING COMMENT IS FROM THE REVIEW OF THE JULY | | | 30, 2019 PLAN SUBMITTAL PACKAGE: | | | | | | 1. SUGGEST SLOPING THE DUMPSTER PAD TO PREVENT STANDING | | | WATER. | | | | | | TRACY L. WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
tward |
Date |
06-12-2019 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2019-06-12 18:12:11 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE JUNE | | | 3, 2019 ROUTED SUBMITTAL PACKAGE: | | | | | | 1. LIST VERTICAL DATUM AND CONVERSION TO NGVD1929 TO | | | ALL SHEETS THAT LIST ELEVATION DATA. (REPEAT COMMENT) | | | | | | 2. SHOW SWALE OR BERM ALONG EAST SIDE OF DRIVEWAY TO | | | PREVENT RUNOFF FROM FLOWING OFFSITE AND INSTEAD BE | | | DIVERTED TO THE DETENTION POND OR GRASSY ISLAND. | | | | | | 3. ADVISORY COMMENT: WHY IS THE SANITARY SEWER MAIN AT | | | 1% SLOPE. MINIMUM ALLOWABLE SLOPE IS 0.4% FOR 8" MAIN. | | | | | | TRACY WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
02-15-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
02-15-2019 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
02-15-2019 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2019-02-15 10:25:58 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. ADD NAVD1988 TO NGVD 1929 CONVERSION EQUATION TO | | | SURVEY. | | | | | | 2. ADD VERTICAL DATUM AND CONVERSION EQUATION TO | | | NGVD1929 TO SHEET 2 OF 6. | | | | | | 3. LIST VERTICAL DATUM AND CONVERSION TO NGVD1929 TO | | | ALL SHEETS THAT LIST ELEVATION DATA. | | | | | | 4. STORM OUTFALL CANNOT CONNECT TO THE SCHOOL DISTRICT | | | STORM PIPE. | | | | | | 5. ROEBUCK ROAD IS MAINTAINED BY PALM BEACH COUNTY. | | | | | | 6. LANDSCAPE PLANS: | | | A. TREE PROPOSED OVER SANITARY LATERAL | | | B. WILL EXISTING PALM TREES BE IMPACTED BY THE | | | INSTALLATION OF THE SANITARY SEWER MAIN. | | | C. CYPRESS TREES PROPOSED ON SIDE SLOPE OF STORMWATER | | | DETENTION POND. | | | | | | 7. LABEL THE CONTOURS OF THE STORMWATER POND. | | | | | | 8. PERVIOUS PAVERS WILL BE CONSIDERED AS IMPERVIOUS | | | AREA. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE A COPY OF THE SFWMD ERP APPROVAL PRIOR TO | | | STARTING CONSTRUCTION. | | | | | | 4. PROVIDE A COPY OF NPBCID PERMIT BEFORE THE START OF | | | CONSTRUCTION. | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
P |
Date |
06-13-2019 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
06-13-2019 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-13 08:14:40 | ANY OUTSTANDING ENGINEERING ISSUES WILL BE ADDRESSED | | | DURING THE ENGINEERING DEVELOPMENT REVIEW PROCESS. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
02-01-2019 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
02-01-2019 |
Time |
07:51 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-02-01 08:01:45 | 1. SHOW AUTO-TURN FOR ENTRANCE AND CIRCULATION. NEED | | | DETAIL FOR APRON. | | | 2. CONNECTIONS FOR WATER AND SEWER NEED TO BE SHOWN | | | WITH METERS, BACKFLOWS, ETC. PLEASE REVIEW PLANNING | | | DEVELOPMENT APPLICATION FOR REQUIRED INFORMATION. | | | 3. WHO IS THE EOR AND FIRM? | | | 4. NEED PROPOSED F.F. ELEV. OF TEMPORARY STRUCTURE. | | | SHOW CONVERSION FACTOR FORM NAVD 88 TO NGVD-29 ON | | | SURVEY AND ENGINEERING PLANS. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
P |
Date |
06-14-2019 |
|
|
Cont ID |
|
| Sent By |
lcamacho |
Date |
06-14-2019 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
lcamacho |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-06-14 09:21:48 | PASSED WITH CONDITION: | | | LETTER FROM COUNTY APPROVING DRIVEWAY CONNECTION IS | | | STILL OUTSTANDING. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
02-06-2019 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-02-06 14:29:02 | 1. PROVIDE COUNTY DRIVEWAY APPROVAL LETTER. | | | 2. CLARIFY THE BASIS OF PARKING REQUIREMENTS. THE | | | PARKING RATE FOR "GOVERNMENT FACILITIES NOT OTHERWISE | | | LISTED" IS 1 PER 200 S.F. | | | 3. CLARIFY THE NEED FOR PERVIOUS PAVING INSTEAD OF | | | STANDARD PAVEMENT. | | | 4. PROVIDE AUTOTURN TRUCK PATHS FOR FIRE TRUCKS TO | | | VERIFY THE CANOPY PLACEMENT AND REQUIRED DRIVEWAY | | | APRON. | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
08-28-2019 |
|
|
Cont ID |
|
| Sent By |
cdglass |
Date |
08-28-2019 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
cdglass |
Date |
08-28-2019 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2019-08-28 09:38:07 | ***PASSED*** | | | | | | CAROLINE GLASS | | | GIS PLANNER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
cdglass |
Date |
08-07-2019 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2019-08-07 16:05:37 | 1. REPEAT COMMENT: PROVIDE INFORMATION/ELEVATION FOR | | | SIGNAGE. DIMENSION SIGN ON SITE PLAN, DIMENSION | | | DISTANCE FROM THE PROPERTY LINES, AND PROVIDE | | | INFORMATION ON THE PROPOSED SIGNAGE. | | | | | | 2. REPEAT COMMENT: IDENTIFY WHAT THE MATERIAL | | | IMMEDIATELY SURROUNDING THE STRUCTURE REPRESENTS. THIS | | | IS NOT IDENTIFIED IN THE SITE PLAN OR THE LANDSCAPE | | | PLAN. THE COMMENTS IN THE RESUBMITTAL NOTES NOTE THAT | | | IT WAS IDENTIFIED BUT IT WAS NOT. | | | | | | 3. REPEAT COMMENT: IDENTIFY THE LOCATION OF ANY | | | MECHANICAL EQUIPMENT OR A/C UNITS. IDENTIFY | | | WALL-MOUNTED EQUIPMENT LOCATIONS ON THE PLANS THAT ARE | | | REFERRED TO IN THE RESUBMITTAL NOTES. | | | | | | 4. REPEAT COMMENT: PLEASE CORRECT MISSING ELEMENTS FROM | | | THE SITE DEVELOPMENT TABLE (FAR) | | | | | | 5. PLEASE PROVIDE AN OFFICIAL COPY OF THE ENVIRONMENTAL | | | REPORT FOR YOUR SUBMITTAL. | | | | | | 6. INCLUDE A STANDARD CITY DETAIL FOR THE TRASH | | | RECEPTACLE. PLEASE NOTE THAT THE STANDARD DETAIL FOR A | | | TRASH RECEPTABLE HAS CHANGED SINCE THE REVIEW PROCESS | | | FOR THIS PROJECT BEGAN. PLEASE UPDATE WITH THE NEW | | | TRASH RECEPTACLE REQUIREMENTS. | | | | | | WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR (4) | | | PAPER COPIES OF THE RESUBMITTAL, ONE (1) 8.5X11 INCH | | | REDUCED COPY, ONE (1) 11X17 INCH REDUCED COPY, AND AN | | | ELECTRONIC COPY OF ALL PLANS. PLEASE NOTE THAT CHANGES | | | ON THE RESUBMITTED PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | THE RESUBMITTAL FEE WILL BE 20 PERCENT OF THE ORIGINAL | | | APPLICATION FEE. | | | | | | CONTACT CAROLINE GLASS AT (561) 822-1431 WITH ANY | | | QUESTIONS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
06-12-2019 |
|
|
Cont ID |
|
| Sent By |
cdglass |
Date |
06-12-2019 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
cdglass |
Date |
06-12-2019 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2019-06-12 10:56:32 | 1. REPEAT COMMENT: PLEASE CORRECT MISSING ELEMENTS FROM | | | THE SITE DEVELOPMENT TABLE (ZONING, FAR, PERCENT OPEN | | | SPACE/LANDSCAPING/BUILDING COVERAGE/IMPERMEABLE | | | SURFACE, ETC.) | | | | | | 2. REPEAT COMMENT: IDENTIFY SETBACKS FROM THE PROPERTY | | | LINE ON THE SITE PLAN. | | | | | | 3. REPEAT COMMENT: TOTAL SITE ACREAGE ON THE SITE PLAN | | | DIFFERS FROM THE TOTAL SITE ACREAGE PROVIDED ON THE | | | PROJECT FACT SHEET. PLEASE CREATE CONSISTENCY BETWEEN | | | THE TWO DOCUMENTS. IDENTIFY WHICH IS CORRECT AND PLEASE | | | PROVIDE AN UPDATED PROJECT FACT SHEET IF NECESSARY. | | | | | | 4. REPEAT COMMENT: PROVIDE INFORMATION/ELEVATION FOR | | | SIGNAGE. DIMENSION SIGN ON SITE PLAN, DIMENSION | | | DISTANCE FROM THE PROPERTY LINES, AND PROVIDE | | | INFORMATION ON THE PROPOSED SIGNAGE. | | | | | | 5. REPEAT COMMENT: IDENTIFY WHAT THE MATERIAL | | | IMMEDIATELY SURROUNDING THE STRUCTURE REPRESENTS. | | | | | | 6. REPEAT COMMENT: CORRECT THE PARKING CALCULATION ON | | | THE SITE PLAN. A MINIMUM OF FOUR (4) PARKING SPACES ARE | | | REQUIRED FOR THE PROJECT. [ZLDR SEC. 94-486] | | | | | | 7. REPEAT COMMENT: INCLUDE AN ADEQUATE TURN-AROUND FOR | | | THE PARKING AREA. THE AMENDED PLANS DO NOT PROVIDE AN | | | ADEQUATE AMOUNT OF SPACE TO TURN AROUND. | | | | | | 8. REPEAT COMMENT: IDENTIFY THE LOCATION OF ANY | | | MECHANICAL EQUIPMENT OR A/C UNITS. GROUND MOUNTED | | | MECHANICAL EQUIPMENT SHOULD NOT PROJECT MORE THAN FOUR | | | FEET INTO A SETBACK [ZLDR SEC. 94-305]. ANY ROOFTOP | | | MATERIAL SHOULD BE SCREENED FROM PUBLIC VIEW BY A | | | PARAPET OR WALL. | | | | | | 9. REPEAT COMMENT: SHOW SITE CIRCULATION PATTERN ON THE | | | SITE PLAN (VEHICLE CIRCULATION). | | | | | | 10. REPEAT COMMENT: INCLUDE A PHOTOMETRIC PLAN FOR ANY | | | PROPOSED SITE LIGHTING. | | | | | | 11. REPEAT COMMENT: INCLUDE DIMENSIONS OF THE PAVED | | | AREA ON THE SITE PLAN. | | | | | | 12. REPEAT COMMENT: CLARIFY WHAT THE 15.78 FT. | | | DIMENSION IS REFERRING TO ON THE SITE PLAN. | | | | | | 13. REPEAT COMMENT: INCLUDE A STANDARD CITY DETAIL FOR | | | THE TRASH RECEPTACLE. | | | | | | 14. DETAIL OF THE PROPOSED PARKING IN THE SITE DETAILS | | | DOES NOT MATCH THE PARKING ON THE SITE PLAN. | | | | | | 15. INCLUDE A STANDARD CITY DETAIL FOR THE BICYCLE | | | PARKING. | | | | | | 16. DIMENSION THE DISTANCE FROM THE TRASH RECEPTACLE TO | | | THE PROPERTY LINE. | | | | | | 17. DIMENSION THE DISTANCE FROM THE FENCE TO THE | | | PROPERTY LINE. | | | | | | 18. THE LEGEND SYMBOLS AND THE SYMBOLS ON THE SITE PLAN | | | DO NOT MATCH. CORRECT ALL SYMBOLS IN THE LEGEND TO | | | MATCH THE SYMBOLS ON THE PLANS. | | | | | | 19. CLEARLY IDENTIFY ALL PROPERTY LINES. | | | | | | 20. PLEASE REMOVE ?TBD? FROM THE DESCRIPTION OF | | | LANDSCAPING ON THE SITE PLAN. | | | | | | 21. THE PROPOSED FENCE IS 8 FEET, AND THE PROPOSED | | | FENCE GATE IS 6 FEET. PLEASE EXPLAIN OR AMEND. | | | | | | 22. CLARIFY WHAT THE 5 FT. DIMENSION DIRECTLY BELOW THE | | | BICYCLE RACK IS REFERRING TO | | | | | | 23. PLEASE CORRECT ERRORS ON THE CANOPY SECTION PAGE OF | | | THE SUBMITTAL. | | | | | | 24. PLEASE PROVIDE LOGICAL ORDERING FOR THE SUBMITTAL | | | IN THE NEXT SUBMITTAL. CURRENTLY, THE PLANS ARE | | | CONFUSING AND OUT OF ORDER (EX. LANDSCAPE INFORMATION | | | IS NOT ALL TOGETHER, SOME LEGENDS AND TABLES ARE SPLIT | | | BETWEEN PAGES AND NOT IN ORDER, NUMBERING IS CONFUSING) | | | | | | 25. CORRECT THE FRONT PAGE OF THE SUBMISSION TO HAVE | | | ACCURATE INFORMATION. | | | | | | INSTRUCTIONS FOR RESUBMITTAL: | | | PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN | | | FORMAT. | | | | | | WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX (6) | | | PAPER COPIES OF THE RESUBMITTAL, ONE (1) 8.5X11 INCH | | | REDUCED COPY, ONE (1) 11X17 INCH REDUCED COPY, AND AN | | | ELECTRONIC COPY OF ALL PLANS. PLEASE NOTE THAT CHANGES | | | ON THE RESUBMITTED PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | THE RESUBMITTAL FEE WILL BE 20 PERCENT OF THE ORIGINAL | | | APPLICATION FEE. | | | | | | CONTACT CAROLINE GLASS AT (561) 822-1431 WITH ANY | | | QUESTIONS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
02-06-2019 |
|
|
Cont ID |
|
| Sent By |
cdglass |
Date |
02-06-2019 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
cdglass |
Date |
02-06-2019 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2019-02-06 10:39:02 | SITE PLAN COMMENTS: | | | 1. PLEASE CORRECT MISSING ELEMENTS FROM THE SITE | | | DEVELOPMENT TABLE (ZONING, FAR, PERCENT OPEN | | | SPACE/LANDSCAPING/BUILDING COVERAGE/IMPERMEABLE | | | SURFACE, ETC.) | | | | | | 2. IDENTIFY SETBACKS FROM THE PROPERTY LINE ON THE SITE | | | PLAN. | | | | | | 3. PROVIDE ELEVATIONS OF THE SITE. THE PROPOSED CANOPY | | | SHOULD BE REPRESENTED IN THE ELEVATIONS. | | | | | | 4. TOTAL SITE ACREAGE ON THE SITE PLAN DIFFERS FROM THE | | | TOTAL SITE ACREAGE PROVIDED ON THE PROJECT FACT SHEET. | | | PLEASE CREATE CONSISTENCY BETWEEN THE TWO DOCUMENTS. | | | | | | 5. PLEASE MORE CLEARLY IDENTIFY THE STRUCTURE ON THE | | | SITE PLAN. IDENTIFY WHAT THE MATERIAL IMMEDIATELY | | | SURROUNDING THE STRUCTURE REPRESENTS. | | | | | | 6. CORRECT THE PARKING CALCULATION ON THE SITE PLAN. A | | | MINIMUM OF FOUR (4) PARKING SPACES ARE REQUIRED FOR THE | | | PROJECT. [ZLDR SEC. 94-486] | | | | | | 7. INCLUDE ALL DIMENSIONS OF PARKING SPACES ON THE SITE | | | PLAN. INCLUDE A DETAIL OF THE PROPOSED PARKING SPACES. | | | PROVIDE WHEEL STOPS. | | | | | | 8. INCLUDE AN ADEQUATE TURN-AROUND FOR THE PARKING | | | AREA. | | | | | | 9. AT LEAST ONE (1) BICYCLE SPACE IS REQUIRED FOR THE | | | PROJECT. PLEASE IDENTIFY BICYCLE PARKING ON THE SITE | | | PLAN. [ZLDR SEC. 94-485(Q)] | | | | | | 10. PROVIDE THE LOCATION AND SCREENING OF THE GARBAGE | | | RECEPTACLES ON THE SITE PLAN. INCLUDE THE STANDARD CITY | | | DETAIL. | | | | | | 11. IDENTIFY THE LOCATION OF ANY MECHANICAL EQUIPMENT | | | OR A/C UNITS. GROUND MOUNTED MECHANICAL EQUIPMENT | | | SHOULD NOT PROJECT MORE THAN FOUR FEET INTO A SETBACK | | | [ZLDR SEC. 94-305]. ANY ROOFTOP MATERIAL SHOULD BE | | | SCREENED FROM PUBLIC VIEW BY A PARAPET OR WALL. | | | | | | 12. SHOW SITE CIRCULATION PATTERN ON THE SITE PLAN. | | | | | | 13. IS THE PROPOSED FENCE IN THE FRONT OF THE PROPERTY | | | 8 FT. HIGH? INCLUDE DIMENSIONS ON THE FENCE IN FRONT OF | | | THE STRUCTURE. | | | | | | 14. THE PROPOSED FENCE APPEARS TO BE WITHIN AN | | | EASEMENT. PLEASE MOVE THE FENCE TO A LOCATION OUTSIDE | | | OF THE EASEMENT. | | | | | | 15. ARE YOU PROPOSING ANY SIGNAGE? IF SO, PROVIDE MORE | | | INFORMATION. | | | | | | 16. ARE YOU PROPOSING SITE LIGHTING? IF SO, INCLUDE A | | | PHOTOMETRIC PLAN. | | | | | | 17. REPLACE THE VICINITY MAP ON THE SITE PLAN (PG. 5 OF | | | SUBMITTAL) WITH A MAP SHOWING THE LOCATION OF THE | | | PROJECT RELATIVE TO THE ENTIRE PARCEL AND ADJUST SCALE | | | FOR CLARITY. | | | | | | 18. THE LOCATION MAP ON THE FRONT PAGE OF THE SUBMITTED | | | PLANS IS INCORRECT. PLEASE CORRECT. | | | | | | 19. INCLUDE DIMENSIONS OF THE PAVED AREA ON THE SITE | | | PLAN. | | | | | | 20. CLARIFY WHAT THE 15.78 FT. DIMENSION IS REFERRING | | | TO ON THE SITE PLAN. | | | | | | INSTRUCTIONS FOR RESUBMITTAL: | | | PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN | | | FORMAT. | | | | | | WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX (6) | | | PAPER COPIES OF THE RESUBMITTAL, ONE (1) 8.5X11 INCH | | | REDUCED COPY, ONE (1) 11X17 INCH REDUCED COPY, AND AN | | | ELECTRONIC COPY OF ALL PLANS. PLEASE NOTE THAT CHANGES | | | ON THE RESUBMITTED PLANS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE. | | | | | | CONTACT CAROLINE GLASS AT (561) 822-1431 WITH ANY | | | QUESTIONS. | | | |
|
|
| |
Print |