Plan Review Details - Project Z18110016
Plan Review Stops For Project Z18110016
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 12-11-2018 Cont ID  
Sent By rbrown Date 12-11-2018 Time 19:44 Rev Time 0.00
Received By rbrown Date 12-11-2018 Time 19:44 Sent To  
Notes
2018-12-11 19:47:09DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. FLOOD ZONE. ACCORDING TO THE ADOPTED FLOOD INSURANCE
 RATE MAPS (FIRMS), THE PROPOSED BUILDING IS IN FLOOD
 ZONE AE, WITH A BASE FLOOD ELEVATION OF 12.2 FT NAVD.
 THE FIRST FLOOR OF THE BUILDING AND ALL ASSOCIATED
 MECHANICAL EQUIPMENT (CHILLERS, GENERATORS ETC.) SHALL
 BE 24 INCHES (FREEBOARD) ABOVE THE BASE FLOOD
 ELEVATION.
  
 3. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 4. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 5. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS,
 FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS,
 GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE,
 SITE IRRIGATION, ETC.
  
 6. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT
 WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL
 HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT
 MICHAEL ORIO, GIS SUPPORT SPECIALIST, AT (561) 494
 1080, OR BY EMAIL: [email protected]
  
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 2 Status P Date 02-14-2019 Cont ID  
Sent By rrossano Date 02-14-2019 Time   Rev Time 0.00
Received By rrossano Date 02-14-2019 Time   Sent To  
Notes
***NONE***

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 12-06-2018 Cont ID  
Sent By RRossano Date 12-06-2018 Time   Rev Time  
Received By rrossano Date 12-06-2018 Time   Sent To I
Notes
2018-12-06 12:32:13PROVIDE CALCULATIONS OF EXISTING AND PROPOSED DEMANDS
 FOR WATER & SEWER (AVERAGE, MAXIMUM AND PEAK) AND FIRE
 FLOW DEMANDS. CALCULATIONS SHALL BE PER FAC 64E-6 FOR
 SEWER AND PER FAC 64-E.008 FOR WATER.
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  
 RICK ROSSANO
 PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1098
 FAX: (561) 494-1116
 MOBILE: (561) 246-9525
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 MANNY GONZALEZ
 SENIOR ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 12-04-2018 Cont ID  
Sent By pleduc Date 12-04-2018 Time   Rev Time 0.00
Received By pleduc Date 12-04-2018 Time 14:20 Sent To  
Notes
2018-12-04 14:38:10THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A
 PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED
 TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE
 REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH
 THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE,
 INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES.
  
 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE
 OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE,
 AND WHETHER IT IS MIXED OR SEPARATED OCCUPANCY.
  
 ONE OF THE THE PROPOSED BUILDINGS INDICATES A STORAGE
 OCCUPANCY; HOWEVER, A STAGE/AMPHITHREATER(ASSEMBLY) IS
 INDICATED. FOR FUTURE SITUATIONS, THE STORAGE AREAS CAN
 NOT BE USED FOR THE GATHERING OF PEOPLE TO PUT ON AN
 EVENT IF IT IS BUILT AND DESIGNED AS A STRORAGE
 OCCUPANCY. CONSIDERATION SHOULD BE GIVEN TO DESIGNING
 THIS BUILDING AS A ASSEMBLY OCCUPANCY IF THE INTENT MAY
 BE TO EXPAND THE USE OF THE STORAGE SPACES.
  
 THE 2ND PROPOSED STORAGE BUILDING PLAN WAS NOT PROVIDED
 AND WAS NOT REVIEWED FOR LIFE SAFETY PURPOSES; HOWEVER,
 A REVIEW OF THE SITE PLAN DID NOT FIND ANY CONCERNS.
  
 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE
 LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER
 SUPPLY IS EXISTING OR WILL BE PROVIDED.
  
 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED
 ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF
 FIRE PREVENTION.
  
 ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE
 BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND
 FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET
 OR ACCESS ROADWAY TO ALLOW FREE
 ACCESS FOR OTHER ARRIVING EMERGENCY VEHICLES.
  
 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER
 THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY
 ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM,
 ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND
 SUBMITTED WITH THE MASTER PLAN.
  
 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL
 BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS,
 EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A
 PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE
 SAFETY FEATURES AND EQUIPMENT.
  
 11. IT IS HIGHLY RECOMMENDED (REQUIRED WITH FIRE
 SPRINKLER SYSTEM) THAT A KNOX BOX WITH KEYS FOR ENTRY
 DOOR LOCKS BE PROVIDED FOR 24 HOUR EMERGENCY ACCESS.
  
 A DOUBLE GATE IS INDICATED AT THE PARKING LOT. THIS
 GATE SHOULD BE PROVIDED WITH A KNOX PADLOCK (IF NOT
 ALREADY PROVIDED) FOR 24 HR ERMERGENCY INCIDENT ACCESS.
  
 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT
 DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL.
  
 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING
 PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH
 THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop L LANDSCAPING
Rev No 2 Status P Date 02-25-2019 Cont ID  
Sent By rcaranci Date 02-25-2019 Time 16:07 Rev Time 0.00
Received By rcaranci Date 02-25-2019 Time 16:07 Sent To  
Notes
2019-02-25 16:07:35FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: SCIENCE CENTER Z18110016
 FEBRUARY 25, 2019
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L.
 PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT
 MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES. NOTE THE PERCENTAGE CLEARLY ON THE
 LANDSCAPE PLAN.
 2. SATISFIED. PROVIDE THE FLORIDA FRIENDLY REQUIRED 50
 POINTS ON THE LANDSCAPE PLAN.
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 12-07-2018 Cont ID  
Sent By rcaranci Date 12-07-2018 Time 16:25 Rev Time 0.00
Received By rcaranci Date 12-07-2018 Time 16:24 Sent To  
Notes
2018-12-07 16:25:20FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: SCIENCE CENTER Z18110016
 DECEMBER 7, 2018
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT
 SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL
 ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT
 SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF
 SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA
 WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA
 LANDSCAPES. NOTE THE PERCENTAGE CLEARLY ON THE
 LANDSCAPE PLAN.
 2. PROVIDE THE FLORIDA FRIENDLY REQUIRED 50 POINTS ON
 THE LANDSCAPE PLAN.
  

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 2 Status P Date 02-15-2019 Cont ID  
Sent By   Date 02-15-2019 Time   Rev Time 0.00
Received By   Date 02-15-2019 Time   Sent To  
Notes
2019-02-15 08:57:08BASED ON PLAN PROVIDED THERE IS ALREADY SANITATION
 SERVICE PROVIDED. PLEASE ENSURE THE CAPACITY OF YOUR
 SERVICE MEETS YOUR REQUIREMENTS. IF NOT CONTACT
 SANITATION AT 561 -822-2085.

Review Stop PW PUBLIC WORKS
Rev No 1 Status P Date 12-13-2018 Cont ID  
Sent By   Date 12-13-2018 Time   Rev Time  
Received By   Date 12-13-2018 Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 1 Status F Date 12-11-2018 Cont ID  
Sent By tward Date 12-11-2018 Time 08:42 Rev Time 0.00
Received By tward Date 12-11-2018 Time 08:44 Sent To  
Notes
2018-12-11 08:44:31THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT
 APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT:
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
  
 1. LABEL THE VERTICAL DATUM ON THE ENGINEERING PLANS.
  
 2. UPDATE THE FEMA FIRM INFORMATION ON THE BOUNDARY
 SURVEY. NEW FIRMS WERE ISSUED IN 2017. BECAUSE THE
 VERTICAL DATUM ON THE SURVEY IS NGVD1929 AND ON THE NEW
 FIRMS IS NAVD1988, THE CONVERSION BETWEEN NAVD1988 AND
 NGVD1929 WILL NEED TO BE SHOWN ON THE SURVEY.
  
 3. SHOW PROPOSED UTILITIES ON THE LANDSCAPE PLANS.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE
 ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS
  
 2. PROVIDE SFWMD ERP MODIFICATION FOR THE DEVELOPMENT.
  
 3. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED
 WITH THE ENGINEERING PERMIT APPLICATION.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120
 [email protected]
  

Review Stop SURVEY SURVEYING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 12-12-2018 Cont ID  
Sent By vnoel Date 12-12-2018 Time 06:54 Rev Time  
Received By vnoel Date 12-12-2018 Time   Sent To  
Notes
2018-12-12 06:54:361. FPL EASEMENT(S) WILL NEED TO BE TERMINATED UNLESS
 AGREED TO BY FPL IN WRITING.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 2 Status P Date 02-20-2019 Cont ID  
Sent By   Date 02-20-2019 Time   Rev Time 0.00
Received By   Date 02-20-2019 Time   Sent To  
Notes
2019-02-20 09:50:47PASSED WITH THE FOLLOWING CONDITIONS OF APPROVAL:
  
 1. PROVIDE COUNTY TRAFFIC CONCURRENCY LETTER
  
 SHING TSOI
 CITY IN-HOUSE TRAFFIC CONSULTANT
 561-494-1141
 [email protected]

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date 12-10-2018 Cont ID  
Sent By   Date 12-10-2018 Time   Rev Time  
Received By   Date 12-10-2018 Time   Sent To  
Notes
2018-12-10 11:18:52Z18110016 SOUTH FLORIDA SCIENCE CENTER 4801 DHEHER
 TRAIL NORTH 11-13-2018 SUBMITTAL
 1. PROVIDE COUNTY TRAFFIC CONCURRENCY LETTER
 2. HOW WILL VEHICLES ACCESS THE STORAGE BUILDINGS? IT
 APPEARS THE DRIVEWAY WITH GATES HAS PARKING SPACES IN
 FRONT OF THEM.
  
 ERIK D. FERGUSON, PE
 CITY TRANSPORTATION ENGINEER

Review Stop Z ZONING
Rev No 2 Status F Date 02-21-2019 Cont ID  
Sent By jroach Date 02-21-2019 Time 13:20 Rev Time 0.00
Received By jroach Date 02-21-2019 Time 13:20 Sent To  
Notes
2019-02-21 13:42:14PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW
 (RESUBMITTAL)
 ___________________________________________
  
 DATE OF REVIEW: 02.21.2019
 PROJECT NO.: Z18110016
 CASE NO.: ISPR 18-13
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS WHICH WERE ISSUED PREVIOUSLY, AND HAVE
 NOT BEEN FULLY SATISFIED:
  
 2. [ PARTIALLY SATISFIED ] - AN APPROVAL LETTER SHALL
 BE PROVIDED FROM THE PALM BEACH COUNTY ENGINEERING
 DEPARTMENT - TRAFFIC DIVISION, INDICATING THAT THE
 PROPOSED EXPANSION COMPLIES WITH THE PALM BEACH COUNTY
 TRAFFIC PERFORMANCE STANDARDS. - THE 2/11/19
 RESUBMITTAL INCLUDED A TRAFFIC STATEMENT INDICATING
 THAT THE PROPOSED IMPROVEMENTS WERE DIMINIMUS, THIS
 REPORT WAS SENT TO PALM BEACH COUNTY FOR THEIR RECORDS;
 WAS ANY RESPONSE RECEIVED? CITY STAFF WOULD LIKE TO
 HAVE A RESPONSE FROM PALM BEACH COUNTY INDICATING
 WHETHER OR NOT THEY CONCUR WITH THE TRAFFIC STATEMENT.
  
 9. [ PARTIALLY SATISFIED ] - THE PROPOSED STORAGE
 BUILDINGS DO NOT APPEAR TO MEET THE MINIMUM BUILDING
 SEPARATION REQUIREMENTS (25 FEET). PLEASE DIMENSION
 BETWEEN ALL EXISTING AND NEW BUILDINGS. - VARIANCE
 APPLICATION WAS RECEIVED ON 2/11/19 AND IS BEING
 PROCESSED. IF APPROVED BY THE ZONING BOARD OF APPEALS
 (ZBA), THEN THIS COMMENT WILL BE REMOVED.
  
 10. [ NOT SATISFIED ] - THE SQUARE FOOTAGE OF THE
 PROPOSED BUILDINGS ON THE SITE PLAN DOES NOT MATCH THAT
 WHICH IS CONTAINED IN THE JUSTIFICATION STATEMENT.
 ENSURE THAT ALL PLANS/DOCUMENTS ARE CONSISTENT AND
 ACCURATE. - THE JUSTIFICATION STATEMENT STILL DOESN'T
 APPEAR TO MATCH THE SITE PLAN.
  
 12. [ NOT SATISFIED ] - ARCHITECTURAL DRAWINGS SHALL BE
 PROVIDED FOR THE PHASE II STORAGE BUILDING. - IF NOT
 BEING PROVIDED PRIOR TO SITE PLAN APPROVAL, THIS
 COMMENT WILL BECOME A CONDITION OF APPROVAL.
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS WHICH ARE NEW:
  
 1. DISTANCES SHALL BE PROVIDED FROM BETWEEN ALL
 STRUCTURES TO SHOW THE BUILDING SEPARATIONS.
  
 2. THE FOLLOWING INFORMATION WAS MISSING FROM THE
 VARIANCE APPLICATION SUBMITTAL: A) ADDRESS LIST; B)
 ENVELOPES; AND C) LABELS.
 ___________________________________________
  
 PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING:
  
 A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL
 DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION.
  
 B) 6 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE
 PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X
 17IN), AND AN ELECTRONIC COPY OF ALL PLANS.
  
 C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO
 ADDITIONAL COMMENTS.
  
 D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
  
 E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
  
 E: [email protected]
  
 W: WPB.ORG
  

Review Stop Z ZONING
Rev No 1 Status F Date 12-12-2018 Cont ID  
Sent By jroach Date 12-12-2018 Time 12:41 Rev Time 0.00
Received By jroach Date 12-12-2018 Time 12:41 Sent To  
Notes
2018-12-12 12:42:05PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 12.12.2018
 PROJECT NO.: Z18110016
 CASE NO.: ISPR 18-13
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS:
  
 1. PURSUANT TO THE LEASE BETWEEN THE CITY AND THE
 SCIENCE MUSEUM, ALL IMPROVEMENTS SHALL BE APPROVED BY
 THE CITY COMMISSION.
  
 2. AN APPROVAL LETTER SHALL BE PROVIDED FROM THE PALM
 BEACH COUNTY ENGINEERING DEPARTMENT ? TRAFFIC DIVISION,
 INDICATING THAT THE PROPOSED EXPANSION COMPLIES WITH
 THE PALM BEACH COUNTY TRAFFIC PERFORMANCE STANDARDS.
  
 3. THE SURVEY PROVIDED IS NOT CURRENT OR ACCURATE; IT
 DOES NOT MATCH WHAT EXISTS ON THE PROPERTY.
  
 4. EXISTING FPL EASEMENTS SHALL BE ABANDONED/MODIFIED
 PRIOR TO PERMITTING.
  
 5. LETTERS SHALL BE PROVIDED FROM ALL UTILITY
 COMPANIES. PLEASE REFER TO THE CITY?S DEVELOPMENT
 APPLICATION.
  
 6. THE PROPOSED EXPANSION NEEDS TO BE ADDED TO THE
 PARKING CALCULATIONS IN THE DATA TABLE.
  
 7. THE PHASE II STORAGE BUILDING DOES NOT MEET THE
 MINIMUM SETBACK REQUIREMENTS.
  
 8. THE OPEN SPACE CALCULATION IN THE DATA TABLE APPEARS
 TO BE INCORRECT.
  
 9. THE PROPOSED STORAGE BUILDINGS DO NOT APPEAR TO MEET
 THE MINIMUM BUILDING SEPARATION REQUIREMENTS (25 FEET).
 PLEASE DIMENSION BETWEEN ALL EXISTING AND NEW
 BUILDINGS.
  
 10. THE SQUARE FOOTAGE OF THE PROPOSED BUILDINGS ON THE
 SITE PLAN DOES NOT MATCH THAT WHICH IS CONTAINED IN THE
 JUSTIFICATION STATEMENT. ENSURE THAT ALL
 PLANS/DOCUMENTS ARE CONSISTENT AND ACCURATE.
  
 11. WHY IS THE EXISTING PARKING IN THE EMPLOYEE PARKING
 LOT DIMENSIONED AT ONLY 8 FEET WIDE? THIS IS A
 RELATIVELY NEW LOT (2013 +/-) AND SHOULD HAVE BEEN
 STRIPED AT 8.5 FEET IN WIDTH. PLEASE CLARIFY.
  
 12. ARCHITECTURAL DRAWINGS SHALL BE PROVIDED FOR THE
 PHASE II STORAGE BUILDING.
  
 13. ON THE LANDSCAPE PLANS, THE LABEL FOR THE
 NORTHERN-MOST FPL EASEMENT IS POINTING TO THE WRONG
 LOCATION.
 ___________________________________________
  
 PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING:
  
 A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL
 DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION.
  
 B) 6 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE
 PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X
 17IN), AND AN ELECTRONIC COPY OF ALL PLANS.
  
 C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO
 ADDITIONAL COMMENTS.
  
 D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
  
 E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 F: 561.822.1460
  
 E: [email protected]
  
 W: WPB.ORG
  

  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved