Plan Review Details - Project Z18100016
| Plan Review Stops For Project Z18100016 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
11-13-2018 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
11-13-2018 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
11-13-2018 |
Time |
18:56 |
Sent To |
|
|
| Notes |
| 2018-11-13 19:18:31 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. FLOOD ZONE. ACCORDING TO THE ADOPTED FLOOD INSURANCE | | | RATE MAPS (FIRMS), THE PROPOSED BUILDING IS IN FLOOD | | | ZONE AE, WITH A BASE FLOOD ELEVATION OF 14 FT NAVD. THE | | | FIRST FLOOR OF THE BUILDING AND ALL ASSOCIATED | | | MECHANICAL EQUIPMENT (CHILLERS, GENERATORS ETC.) SHALL | | | BE 24 INCHES (FREEBOARD) ABOVE THE BASE FLOOD | | | ELEVATION. | | | | | | 3. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 4. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 5. BUILDING ADDRESS. EACH SEPARATE BUILDING, AND UNIT | | | WITH AN INDEPENDENT ENTRANCE FROM THE STREET, SHALL | | | HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT | | | MICHAEL ORIO, GIS SUPPORT SPECIALIST, AT (561) 494 | | | 1080, OR BY EMAIL: [email protected] | | | | | | 6. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
P |
Date |
02-20-2019 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
02-20-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
02-20-2019 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
01-08-2019 |
|
|
Cont ID |
|
| Sent By |
RRossano |
Date |
01-08-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
01-08-2019 |
Time |
|
Sent To |
|
|
| Notes |
| 2019-01-08 08:54:09 | PASSED WITH PROVISO: FOR ENGINEERING SUBMITTAL REVIEW, | | | PLEASE CONNECT SEWER LATERALS TO GRAVITY, NOT FORCE | | | MAIN. | | | | | | COMMENT PER MANNY GONZALEZ | | | SENIOR ENGINEERING PROJECT COORDINATOR | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | MOBILE: (561) 644-7301 | | | EMAIL: [email protected] | | | WWW.WPB.ORG/ENGINEERING | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
11-09-2018 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
11-09-2018 |
Time |
|
Rev Time |
|
| Received By |
rrossano |
Date |
11-09-2018 |
Time |
|
Sent To |
I |
|
| Notes |
| 2018-11-09 12:31:37 | COMMENTS PER MANNY GONZALEZ, SENIOR PROJECT | | | COORDINATOR, CITY OF WPB ENGINEERING | | | METERED SERVICES TO BE MOVED RIGHT OF 12 FT. EASEMENT | | | PROVIDE LEGAL & SKETCH, IF EXISTING EASEMENT IS | | | ELIGIBLE | | | PROVIDE FLOWS ? LS 80 ? ASSESS CONDITION. CALL OUT LS | | | NUMBERS. | | | PROVIDE OVER-ALL UTILITY PLAN ? 4? & 8? | | | WATER/SEWER/DRAINAGE. | | | SHOW EXISTING & PROPOSED WATER LINES. | | | PROVIDE LEVEL OF SERVICE FOR PROPOSED 208 BEDS ? 20,800 | | | GPD (35 GPM X 140 GPM) | | | PROVIDE SANITARY SEWER FLOWS FROM DOWNSTREAM LIFT | | | STATION (COMING FROM DEALER/SHOPPING CENTER TO THE | | | SOUTH) | | | | | | COMMENTS PER RICK ROSSANO, PROJECT COORDINATOR, CITY OF | | | WPB ENGINEERING | | | ADD SHEET 5 EASEMENTS. | | | AS OF DECEMBER 20, 2015, THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | STATING "ALL BACKFLOW DEVICES MUST BE LEAD-FREE". FOR | | | MORE INFORMATION, REFER TO THE LINK BELOW: | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | | | | SUPPLY POLLUTION CONTROL PLAN SHOWING: | | | A) WHERE SILT SCREENS WILL BE INSTALLED, | | | B) SHOW THE PROTECTION OF ALL ON-SITE CATCH BASINS | | | C) SHOW PROTECTION OF ALL OFF-SITE CATCH BASINS | | | D) INCLUDE DETAILS AS TO THE TYPE OF PROTECTION USED ON | | | THE CATCH BASINS | | | E) SHOW HOW SITE DIRT WILL NOT BE TRACKED INTO THE | | | ROADS | | | HTTP://WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/DOCS/ | | | CONST_ACTIVITY.PDF | | | HTTP://WWW.PBCO-NPDES.ORG/CONSTRUN.HTML | | | HTTP://WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/FAQS. | | | HTM | | | | | | GENERAL DRIVEWAY COMMENTS | | | 1) DIMENSION DRIVEWAYS, LOCATED HORIZONTALLY AND | | | VERTICALLY. CALL OUT SETBACK. | | | 2) SHOW PROPOSED CONCRETE APRON(S), CITY STANDARD | | | DETAIL IS REQUIRED, SEE LINK BELOW: HTTP://WPB.ORG/DEPA | | | RTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICA | | | TIONS | | | 3) IF USING PAVERS IN THE APRON AREA OF THE PROPOSED | | | DRIVEWAY, YOU MUST EXECUTE A PAVER DRIVEWAY AGREEMENT, | | | WHICH CAN BE OBTAINED HERE: HTTP://WPB.ORG/DEPARTMENTS/ | | | ENGINEERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | GENERAL - | | | | | | THE FOLLOWING COMMENTS ARE INCLUDED FOR YOUR GENERAL | | | INFORMATION AND USE. THEY MAY NOT BE SITE-SPECIFIC, BUT | | | WILL SOON BE ADDED TO CITY OF WEST PALM BEACH | | | DEVELOPMENT PERMIT APPLICATIONS. | | | | | | OBTAIN AVAILABLE UTILITIES OWNED BY THE CITY OF WEST | | | PALM BEACH WITHIN THE PUBLIC RIGHT-OF-WAY FOR THE | | | ENTIRE EXTENT OF THE LIMITS OF YOUR PROJECT. IDENTIFY | | | TYPE OF UTILITY, LOCATION, PIPE MATERIAL, AGE AND SIZE. | | | SUBMIT A FORMAL RECORDS REQUEST (WITH SUNSHINE DESIGN | | | TICKET NUMBER) TO JANICE TARBILL IN THE WPB ENGINEERING | | | SERVICES DEPARTMENT AT [email protected]. SUBMIT PROOF | | | OF THE FORMAL RECORD REQUEST TO THE CITY. NOTE: RECORD | | | INFORMATION PROVIDED BY THE CITY IS FOR REFERENCE ONLY. | | | PERFORM FIELD VERIFICATION OF EXACT LOCATION AND DEPTH | | | BY SOFT-DIGS, POT-HOLING, ETC. | | | | | | PROVIDE SCHEMATIC UTILITY ENGINEERING DRAWINGS (24IN X | | | 36IN FORMAT) AT A LEGIBLE ENGINEERING SCALE AND | | | PREPARED BY A LICENSED PROFESSIONAL ENGINEER. | | | | | | PROVIDE STATEMENT, CONFIRMED BY ENGINEERING ANALYSIS, | | | THAT THE EXISTING UTILITY MAINS SERVING THE PROPOSED | | | PROJECT ARE ADEQUATE. PROVIDE CALCULATIONS OF EXISTING | | | AND PROPOSED WATER & SEWER DEMANDS (AVERAGE, MAXIMUM, | | | PEAK) AND FIRE FLOW DEMAND. CALCULATIONS SHALL BE PER | | | FAC 64E-6 FOR SEWER AND PER FAC 64-E.008 FOR WATER. | | | | | | LOCATIONS, SIZES AND OTHER APPROPRIATE DESCRIPTIONS OF | | | THE FOLLOWING EXISTING OR PROPOSED UTILITY FACILITIES: | | | ? WATER MAINS, SERVICE CONNECTIONS, VALVES, METERS AND | | | ANY SPECIAL STRUCTURES SUCH AS PUMP STATIONS; | | | ? SANITARY SEWER MAINS, SERVICE CONNECTIONS AND ANY | | | SPECIAL STRUCTURES OR FACILITIES SUCH AS LIFT STATIONS, | | | SEPTIC SYSTEMS; AND | | | ? PROVIDE CCTV VIDEO OF EXISTING SANITARY SEWER MAINS | | | ALONG ENTIRE PROJECT FRONTAGE. | | | STORMWATER DRAINAGE MAINS, CHANNELS, RETENTION OR | | | DETENTION PONDS, AND OTHER MAJOR DRAINAGE FACILITIES; | | | FLOW DIRECTION OF SURFACE RUNOFF. | | | SHOW LOCATION OF ALL EXISTING DRY/FRANCHISE UTILITIES, | | | AND ALL RELATED EASEMENTS ON THE SITE OR ON IMMEDIATELY | | | ADJACENT PROPERTY. | | | PROVIDE PROFILE VIEW OF ALL PROPOSED UTILITIES WITHIN | | | THE RIGHT-OF-WAY TO BE OWNED AND MAINTAINED BY THE | | | CITY. CALL OUT VERTICAL CLEARANCES OF UTILITY CROSSINGS | | | WITH CITY AND DRY/FRANCHISE UTILITIES. IDENTIFY TYPE OF | | | UTILITY/OWNERSHIP, LOCATION/DEPTH, PIPE MATERIAL, SIZE. | | | SHOW CONDITIONS ON IMMEDIATELY ADJACENT PROPERTY THAT | | | HAVE A DIRECT IMPACT ON THE PROPOSED DEVELOPMENT |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
11-01-2018 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
11-01-2018 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
11-01-2018 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2018-11-01 15:42:15 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, SPECICALLY BUT NOT LIMITED TO, | | | CHAPTER 28 NEW HOTELS AND DORMITORIES, AND ALL | | | ASSOCIATED FIRE CODES. | | | | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE | | | OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE. | | | | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE | | | LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER | | | SUPPLY IS EXISTING OR WILL BE PROVIDED. ENSURE THAT A | | | FIRE PUMP WILL NOT BE NEEDED TO DELIVER THE APPLICABLE | | | WATER SUPPLY TO THE FIRE SPRINKLER SYSTEM AT MOST | | | REMOTE AND/OR HIGHEST DEMAND AREA. | | | | | | THE ENTIRE ACCESS ROAD WILL CONSIDERED A FIRE LANE AND | | | SHALL REQUIRE ADAQUATE FIRE LANE MARKINGS AND/OR | | | SIGNAGE. | | | | | | THERE IS AN INDICATION OF A COVERED CANOPY OVER THE | | | FIRE LANE. THE MINIMUM HEIGHT CLEARANCE SHALL BE 13'6". | | | | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. THE PROPOSED FIRE HYDRANT LOCATION IS | | | ACCEPTABLE; HOWEVER, NO FDC WAS SHOWN. | | | | | | ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CLASSIFICATION. FOR ANY LIFE | | | SAFETY ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE | | | ALARM, ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FAC | | | 61G AND SUBMITTED WITH THE MASTER PLAN. SEPARATE SHOP | | | DRAWINGS WILL THEN BE REQUIRED THAT WILL BE BASED ON | | | THESE FAC 61G DOCUMENTS. | | | | | | | | | 10. COMPLETE LIFE SAFETY PLANS SHALL BE PROVIDED THAT | | | ILLUSTRATE OCCUPANT LOADS, TRAVEL DISTANCES, COMMON | | | PATHS OF TRAVEL, DEAD-END CORRIDORS, EXIT SIGNS, | | | EMERGENCY LIGHTING, EXITS LEADING TO A PUBLIC WAY, FIRE | | | EXTINGUISHER LOCATIONS, AND ALL FIRE SAFETY FEATURES | | | AND EQUIPMENT. | | | | | | | | | ON REVIEW OF THE PROPOSED FLOOR PLAN, SEVERAL DOORS | | | OPEN INTO THE EXIT ACCESS CORRIDOR. PLEASE REVIEW NFPA | | | 101, CHAPTER 7, MEANS OF EGRESS, | | | | | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | | OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE | | | REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY, | | | OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT | | | MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A | | | CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN, | | | UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET: | | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | | EXISTING BUILDING. | | | (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS | | | PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED | | | WIDTH OF THE STAIR LANDING WHEN THE DOOR | | | LEAF IS FULLY OPEN. | | | | | | | | | 11. IT IS REQUIRED WITH FIRE SPRINKLER SYSTEM THAT A | | | KNOX BOX WITH KEYS FOR ENTRY DOOR LOCKS BE PROVIDED FOR | | | 24 HOUR EMERGENCY ACCESS. | | | | | | | | | 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE ITS FINAL REVIEW OR APPROVAL. | | | | | | | | | 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
P |
Date |
03-18-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
03-18-2019 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
03-18-2019 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2019-03-18 11:53:19 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: KEISER UNIVERSITY DORMS Z18100016 | | | MARCH 18, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. CORRECTIONS NEED TO BE MADE TO THE TREE DISPOSITION | | | PLAN: | | | ? SATISFIED. PROVIDE THE CURRENT CANOPY DIAMETER FOR | | | EACH TREE | | | ? SATISFIED. SHOW CALCULATIONS FOR CANOPY SQUARE | | | FOOTAGE BASED ON DIAMETER, 1:1 SAME CATEGORY IF UNDER | | | 20 FEET, ACTUAL AREA 20 FEET OR MORE. | | | CORRECT FOR MAHOGANY, LIVE OAKS, SLASH PINES CATEGORY 1 | | | AT 300 SQ FT, PIGEON PLUM CATEGORY 2 AT 150 SQ FT, | | | BISCHOFIA NO REQUIRED MITIGATION. | | | ? SATISFIED. CALCULATE ALL TREE CANOPY REMOVED, AND | | | PROVIDE TOTAL MITIGATION REQUIRED. | | | ? SATISFIED. PROVIDE A TOTAL CANOPY CREDIT FOR ALL | | | TREES ADDED AS PROPOSED. | | | REVISE TOTAL USING SPECIES ON PLANT LIST. | | | STAFF CONTACTED SCOTT BARBER, LANDSCAPE ARCHITECT AND | | | REVIEWED THE CORRECTIONS ON 3/5/19. | | | | | | 2. SATISFIED. SECTION 94-448(D)(3) REQUIRES ALL NATIVE | | | TREES AND PALMS IN GOOD CONDITION MUST BE RELOCATED. | | | PROVIDE THE CONDITION FOR EACH TREE IN A COLUMN ON THE | | | TREE DISPOSITION LIST, AND DESCRIBE IF SPECIES CAN BE | | | RELOCATED. | | | | | | 3. SATISFIED. EXPLAIN THE REASON FOR SELECTION OF | | | HIGHRISE LIVE OAKS, AS SPECIES LIVE OAKS PROVIDE MORE | | | GENETIC DIVERSITY AND RESISTANCE TO INSECTS AND | | | DISEASE. | | | | | | 4. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING | | | LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION | | | 94-443(C)(3) AND (4) SHOWING ONLY THE AREAS WITHIN THE | | | PARKING FIELD, AND THE TOTAL SHOWN TO MEET THE TOTALS | | | OF BOTH SECTIONS ADDED TOGETHER. | | | | | | 5. SATISFIED. PROVIDE A TREE IN THE NONCONFORMING | | | TERMINAL ISLAND TO THE EAST OF THE RECONFIGURED ROW OF | | | PARKING ADJACENT TO THE EXISTING BUILDING. | | | | | | 6. SATISFIED. SHOW ALL PARKING SPACE ROW COUNTS ON THE | | | LANDSCAPE PLAN. | | | | | | 7. SATISFIED. PROVIDE A FLORIDA FRIENDLY LANDSCAPE | | | CHART AND SHOW 50 REQUIRED POINTS PER SECTION | | | 94-442(G). | | | | | | 8. SATISFIED. SHOW THE LOCATIONS OF WATER AND SEWER | | | LINES ON THE LANDSCAPE PLAN AND CORRECT CONFLICTS WITH | | | TREES AND LANDSCAPING. RELOCATE UTILITY LOCATIONS OR | | | EXPAND LANDSCAPE AREAS TO ACCOMMODATE REQUIRED | | | LANDSCAPING. | | | 9. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | | | | 10. SATISFIED. PLEASE PROVIDE SCREENING FOR ALL ABOVE | | | GROUND UTILITY VALVES AND BACKFLOW PREVENTERS. | | | ADDITIONAL COMMENTS 3/5/19: | | | | | | 11. SATISFIED. LIVE OAK TO THE EAST AND SOUTH OF | | | PROPOSED BUILDING IS TOO CLOSE TO EXISTING DRAINAGE | | | LINE. MOVE AT LEAST 15 FEET FROM LINE. | | | | | | 12. SATISFIED. PLEASE SUBMIT LANDSCAPE PLANS AND TREE | | | MITIGATION PLAN TOGETHER, SIGNED AND SEALED BY LA. | | | 13. SATISFIED. GUMBO LIMBO SHOULD BE ON RELOCATE LIST | | | IF IN GOOD CONDITION. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
03-05-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
03-05-2019 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
03-05-2019 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2019-03-05 12:45:55 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: KEISER UNIVERSITY DORMS Z18100016 | | | MARCH 5, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. CORRECTIONS NEED TO BE MADE TO THE TREE DISPOSITION | | | PLAN: | | | ? SATISFIED. PROVIDE THE CURRENT CANOPY DIAMETER FOR | | | EACH TREE | | | ? NOT SATISFIED. SHOW CALCULATIONS FOR CANOPY SQUARE | | | FOOTAGE BASED ON DIAMETER, 1:1 SAME CATEGORY IF UNDER | | | 20 FEET, ACTUAL AREA 20 FEET OR MORE. | | | CORRECT FOR MAHOGANY, LIVE OAKS, SLASH PINES CATEGORY 1 | | | AT 300 SQ FT, PIGEON PLUM CATEGORY 2 AT 150 SQ FT, | | | BISCHOFIA NO REQUIRED MITIGATION. | | | ? PARTIALLY SATISFIED. CALCULATE ALL TREE CANOPY | | | REMOVED, AND PROVIDE TOTAL MITIGATION REQUIRED. | | | REVISE TOTAL. SHOULD BE 9,441. | | | ? PROVIDE A TOTAL CANOPY CREDIT FOR ALL TREES ADDED AS | | | PROPOSED. | | | REVISE TOTAL USING SPECIES ON PLANT LIST. | | | STAFF CONTACTED SCOTT BARBER, LANDSCAPE ARCHITECT AND | | | REVIEWED THE CORRECTIONS ON 3/5/19. | | | | | | 2. SATISFIED. SECTION 94-448(D)(3) REQUIRES ALL NATIVE | | | TREES AND PALMS IN GOOD CONDITION MUST BE RELOCATED. | | | PROVIDE THE CONDITION FOR EACH TREE IN A COLUMN ON THE | | | TREE DISPOSITION LIST, AND DESCRIBE IF SPECIES CAN BE | | | RELOCATED. | | | | | | 3. SATISFIED. EXPLAIN THE REASON FOR SELECTION OF | | | HIGHRISE LIVE OAKS, AS SPECIES LIVE OAKS PROVIDE MORE | | | GENETIC DIVERSITY AND RESISTANCE TO INSECTS AND | | | DISEASE. | | | | | | 4. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING | | | LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION | | | 94-443(C)(3) AND (4) SHOWING ONLY THE AREAS WITHIN THE | | | PARKING FIELD, AND THE TOTAL SHOWN TO MEET THE TOTALS | | | OF BOTH SECTIONS ADDED TOGETHER. | | | | | | 5. SATISFIED. PROVIDE A TREE IN THE NONCONFORMING | | | TERMINAL ISLAND TO THE EAST OF THE RECONFIGURED ROW OF | | | PARKING ADJACENT TO THE EXISTING BUILDING. | | | | | | 6. SATISFIED. SHOW ALL PARKING SPACE ROW COUNTS ON THE | | | LANDSCAPE PLAN. | | | | | | 7. SATISFIED. PROVIDE A FLORIDA FRIENDLY LANDSCAPE | | | CHART AND SHOW 50 REQUIRED POINTS PER SECTION | | | 94-442(G). | | | | | | 8. SATISFIED. SHOW THE LOCATIONS OF WATER AND SEWER | | | LINES ON THE LANDSCAPE PLAN AND CORRECT CONFLICTS WITH | | | TREES AND LANDSCAPING. RELOCATE UTILITY LOCATIONS OR | | | EXPAND LANDSCAPE AREAS TO ACCOMMODATE REQUIRED | | | LANDSCAPING. | | | 9. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | | | | 10. SATISFIED. PLEASE PROVIDE SCREENING FOR ALL ABOVE | | | GROUND UTILITY VALVES AND BACKFLOW PREVENTERS. | | | ADDITIONAL COMMENTS 3/5/19: | | | | | | 11. LIVE OAK TO THE EAST AND SOUTH OF PROPOSED BUILDING | | | IS TOO CLOSE TO EXISTING DRAINAGE LINE. MOVE AT LEAST | | | 15 FEET FROM LINE. | | | | | | 12. PLEASE SUBMIT LANDSCAPE PLANS AND TREE MITIGATION | | | PLAN TOGETHER, SIGNED AND SEALED BY LA. | | | 13. GUMBO LIMBO SHOULD BE ON RELOCATE LIST IF IN GOOD | | | CONDITION. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
01-22-2019 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-22-2019 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-22-2019 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2019-01-22 17:02:18 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: KEISER UNIVERSITY DORMS Z18100016 | | | JANUARY 15, 2019 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. CORRECTIONS NEED TO BE MADE TO THE TREE DISPOSITION | | | PLAN: | | | ? SATISFIED. PROVIDE THE CURRENT CANOPY DIAMETER FOR | | | EACH TREE | | | ? NOT SATISFIED. SHOW CALCULATIONS FOR CANOPY SQUARE | | | FOOTAGE BASED ON DIAMETER, 1:1 SAME CATEGORY IF UNDER | | | 20 FEET, ACTUAL AREA 20 FEET OR MORE. | | | CORRECT FOR MAHOGANY, LIVE OAKS, SLASH PINES CATEGORY 1 | | | AT 300 SQ FT, PIGEON PLUM CATEGORY 2 AT 150 SQ FT, | | | BISCHOFIA NO REQUIRED MITIGATION. | | | ? PARTIALLY SATISFIED. CALCULATE ALL TREE CANOPY | | | REMOVED, AND PROVIDE TOTAL MITIGATION REQUIRED. | | | REVISE TOTAL. SHOULD BE 9,441. | | | ? PROVIDE A TOTAL CANOPY CREDIT FOR ALL TREES ADDED AS | | | PROPOSED. | | | REVISE TOTAL USING SPECIES ON PLANT LIST. | | | | | | 2. NOT SATISFIED. SECTION 94-448(D)(3) REQUIRES ALL | | | NATIVE TREES AND PALMS IN GOOD CONDITION MUST BE | | | RELOCATED. PROVIDE THE CONDITION FOR EACH TREE IN A | | | COLUMN ON THE TREE DISPOSITION LIST, AND DESCRIBE IF | | | SPECIES CAN BE RELOCATED. | | | | | | 3. SATISFIED. EXPLAIN THE REASON FOR SELECTION OF | | | HIGHRISE LIVE OAKS, AS SPECIES LIVE OAKS PROVIDE MORE | | | GENETIC DIVERSITY AND RESISTANCE TO INSECTS AND | | | DISEASE. | | | | | | 4. SATISFIED. PROVIDE A PLAN SHOWING THE PARKING | | | LANDSCAPE AREAS COUNTED TOWARD COMPLIANCE WITH SECTION | | | 94-443(C)(3) AND (4) SHOWING ONLY THE AREAS WITHIN THE | | | PARKING FIELD, AND THE TOTAL SHOWN TO MEET THE TOTALS | | | OF BOTH SECTIONS ADDED TOGETHER. | | | | | | 5. SATISFIED. PROVIDE A TREE IN THE NONCONFORMING | | | TERMINAL ISLAND TO THE EAST OF THE RECONFIGURED ROW OF | | | PARKING ADJACENT TO THE EXISTING BUILDING. | | | | | | 6. SATISFIED. SHOW ALL PARKING SPACE ROW COUNTS ON THE | | | LANDSCAPE PLAN. | | | | | | 7. SATISFIED. PROVIDE A FLORIDA FRIENDLY LANDSCAPE | | | CHART AND SHOW 50 REQUIRED POINTS PER SECTION | | | 94-442(G). | | | | | | 8. SATISFIED. SHOW THE LOCATIONS OF WATER AND SEWER | | | LINES ON THE LANDSCAPE PLAN AND CORRECT CONFLICTS WITH | | | TREES AND LANDSCAPING. RELOCATE UTILITY LOCATIONS OR | | | EXPAND LANDSCAPE AREAS TO ACCOMMODATE REQUIRED | | | LANDSCAPING. | | | 9. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | | | | 10. SATISFIED. PLEASE PROVIDE SCREENING FOR ALL ABOVE | | | GROUND UTILITY VALVES AND BACKFLOW PREVENTERS. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
11-13-2018 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
11-13-2018 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
11-13-2018 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2018-11-13 15:10:45 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: KEISER UNIVERSITY DORMS Z18100016 | | | NOVEMBER 13, 2018 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. CORRECTIONS NEED TO BE MADE TO THE TREE DISPOSITION | | | PLAN: | | | ? PROVIDE THE CURRENT CANOPY DIAMETER FOR EACH TREE | | | ? SHOW CALCULATIONS FOR CANOPY SQUARE FOOTAGE BASED ON | | | DIAMETER, 1:1 SAME CATEGORY IF UNDER 20 FEET, ACTUAL | | | AREA 20 FEET OR MORE. | | | ? CALCULATE ALL TREE CANOPY REMOVED, AND PROVIDE TOTAL | | | MITIGATION REQUIRED. | | | ? PROVIDE A TOTAL CANOPY CREDIT FOR ALL TREES ADDED AS | | | PROPOSED. | | | | | | 2. SECTION 94-448(D)(3) REQUIRES ALL NATIVE TREES AND | | | PALMS IN GOOD CONDITION MUST BE RELOCATED. PROVIDE THE | | | CONDITION FOR EACH TREE IN A COLUMN ON THE TREE | | | DISPOSITION LIST, AND DESCRIBE IF SPECIES CAN BE | | | RELOCATED. | | | | | | 3. EXPLAIN THE REASON FOR SELECTION OF HIGHRISE LIVE | | | OAKS, AS SPECIES LIVE OAKS PROVIDE MORE GENETIC | | | DIVERSITY AND RESISTANCE TO INSECTS AND DISEASE. | | | | | | 4. PROVIDE A PLAN SHOWING THE PARKING LANDSCAPE AREAS | | | COUNTED TOWARD COMPLIANCE WITH SECTION 94-443(C)(3) AND | | | (4) SHOWING ONLY THE AREAS WITHIN THE PARKING FIELD, | | | AND THE TOTAL SHOWN TO MEET THE TOTALS OF BOTH SECTIONS | | | ADDED TOGETHER. | | | | | | 5. PROVIDE A TREE IN THE NONCONFORMING TERMINAL ISLAND | | | TO THE EAST OF THE RECONFIGURED ROW OF PARKING ADJACENT | | | TO THE EXISTING BUILDING. | | | | | | 6. SHOW ALL PARKING SPACE ROW COUNTS ON THE LANDSCAPE | | | PLAN. | | | | | | 7. PROVIDE A FLORIDA FRIENDLY LANDSCAPE CHART AND SHOW | | | 50 REQUIRED POINTS PER SECTION 94-442(G). | | | | | | 8. SHOW THE LOCATIONS OF WATER AND SEWER LINES ON THE | | | LANDSCAPE PLAN AND CORRECT CONFLICTS WITH TREES AND | | | LANDSCAPING. RELOCATE UTILITY LOCATIONS OR EXPAND | | | LANDSCAPE AREAS TO ACCOMMODATE REQUIRED LANDSCAPING. | | | | | | | | | 9. PLEASE PROVIDE SCREENING FOR ALL ABOVE GROUND | | | UTILITY VALVES AND BACKFLOW PREVENTERS. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
N |
Date |
11-14-2018 |
|
|
Cont ID |
|
| Sent By |
|
Date |
11-14-2018 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
11-14-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-11-14 12:01:04 | NOT REQUIRED FOR APPROVAL NOW BUT WHEN PLANS TO BUILD | | | COME IN PLEASE ENSURE YOU HAVE LOOKED AT YOUR | | | SANITATION PLAN AND HAVE TAKEN INTO ACCOUNT HOW AND HOW | | | MUCH CAPACITY YOU WILL NEED. |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
3 |
Status |
P |
Date |
03-05-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
03-05-2019 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
03-05-2019 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2019-03-05 17:36:18 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | FEBRUARY 19, 2019 SUBMITTAL PACKAGE: | | | | | | 1. REVISE THE NGVD 1929 FFE FOR THE PROPOSED BUILDING | | | (ON SEVERAL CIVIL SHEETS). VERTICAL DATUM CONVERSION | | | BETWEEN NAVD 1988 AND NGVD 1929 IS SHOWN AS 1.54 FEET. | | | 1.53 FEET WAS USED FOR THE FFE CONVERSION. | | | | | | 2. STAFF CANNOT FIND THE VERTICAL DATUM REFERENCE AND | | | CONVERSION EQUATION TO NGVD 1929 ON SHEET C-6 (REPEAT | | | COMMENT). | | | | | | 3. VERIFY THE STORM PIPE SIZE (15" HDPE) LISTED FOR | | | UTILITY CROSSINGS 1 AND 2 ON SHEET C-6. SHEET C-5 SHOWS | | | AN 18" HDPE ON THE SOUTH SIDE OF THE TYPE 'V' GUTTER | | | INTLET. | | | | | | 4. SHEET C-5 SHOWS A SPOT GRADE OF 18.25 FEET NAVD 1988 | | | IN THE PERVIOUS AREA IN THE MIDDLE OF THE PAVED DRIVE | | | AND ALSO BETWEEN CONTOURS 17 AND 18. AN ADDITIONAL 18 | | | CONTOUR LINE IS NEEDED SOUTH OF THE SPOT GRADE. | | | | | | 5. BUILDING APPEARS TO BE PROPOSED WITHIN A SPECIAL | | | FLOOD HAZARD AREA (SFHA). THE FEMA FLOOD ELEVATION | | | SHOULD BE LISTED ON THE SURVEY. MINIMUM 2 FEET OF | | | FREEBOARD IS REQUIRED FOR STRUCTURES CONSTRUCTED WITHIN | | | A SFHA. | | | | | | TRACY L. WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
01-22-2019 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
01-22-2019 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
01-22-2019 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2019-01-22 09:14:49 | THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE | | | JANUARY 7, 2019 SUBMITTAL PACKAGE: | | | | | | 1. VERIFY THE VERTICAL DATUM USED ON THE ENGINEERING | | | PLANS. DATUM NOTES ON SHEETS C-1, C-3, C-5, AND C-7 | | | INDICATE VERTICAL DATUM USED IS NGVD 1929 BUT THE GRADE | | | ELEVATIONS SHOWN ON SHEET C-5 APPEAR TO BE REFERENCED | | | TO NAVD 1988. | | | | | | 2. THERE ARE TWO CONVERSION EQUATIONS PROVIDED FOR THE | | | NGVD1929 AND NAVD1988 RELATIONSHIP (1.504 FEET AND 1.53 | | | FEET). | | | | | | 3. LABEL THE VERTICAL DATUM ON SHEET C-6 AND PROVIDE | | | CONVERSION EQUATION TO NGVD 1929. | | | | | | 4. ON SHEET C-6, LABEL THE LOCATION OF THE UTILITY | | | CROSSINGS CORRESPONDING TO THE UTILITY CROSSING | | | SCHEDULE AT THE BOTTOM OF THE SHEET. | | | | | | 5. SITE NOTE 3 ON SHET C-4 - PBC MAY HAVE UPDATED THEIR | | | TP-13 TYPICAL PAVEMENT MARKINGS. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
11-09-2018 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
11-09-2018 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
11-09-2018 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2018-11-09 14:04:02 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP:// | | | WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER | | | MITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. THE CITY VERTICAL DATUM IS NGVD 1929. THE CITY HAS | | | ALLOWED THE USE OF NAVD 1988 PROVIDED THE CONVERSION | | | EQUATION TO NGVD 1929 IS PROVIDED. THE CONVERSION | | | EQUATION IS NEEDED ON THE SURVEY. | | | | | | 2. LABEL THE VERTICAL DATUM ON THE ENGINEERING PLANS | | | AND PROVIDE THE CONVERSION EQUATION TO NGVD1929. | | | | | | 3. CERTAIN LAYERS APPEAR TO BE MISSING ON THE | | | ENGINEERING PLANS. FOR EXAMPLE, SHEET C4 (PAVING, | | | GRADING AND DRAINAGE PLAN) DOES NOT SHOW THE PROPOSED | | | IMPROVEMENTS OR EXISTING WATER AND SEWER MAINS. SHEET | | | C-5 (UTILITY PLAN) DOES NOT SHOW EXISTING WATER AND | | | SEWER MAINS. | | | | | | 4. CHECK THE HGL FOR THE EXISTING DRAINAGE SYSTEM TO | | | DETERMINE THE ADDITIONAL FLOW WILL NOT CAUSE FLOODING. | | | | | | 5. PROVIDE A PROJECT BOUNDARY ON SHEET C-2 (SITE PLAN) | | | THAT CORRESPONDS TO THE LAND USE AREAS LISTED ON THE | | | SAME SHEET. | | | | | | 6. PROVIDE AN STORMWATER MASTER PLAN FOR THE ENTIRE | | | CAMPUS THAT TAKES INTO ACCOUNT FUTURE DEVELOPMENTS. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | 3. PROVIDE A COPY OF THE MODIFIED SFWMD ERP APPROVAL | | | PRIOR TO STARTING CONSTRUCTION. | | | | | | 4. PROVIDE A COPY OF THE MODIFIED NPBCID APPROVAL PRIOR | | | TO START OF CONSTRUCTION. | | | | | | | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
3 |
Status |
P |
Date |
03-06-2019 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
03-06-2019 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-03-06 07:39:44 | PASSED WITH CONDITION OF MASTER WATER AND SEWER PLAN IS | | | SUBMITTED, REVIEWED AND ANY REQUIRED EASEMENTS GRANTED | | | TO CITY PRIOR TO C.O. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
F |
Date |
01-24-2019 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
01-24-2019 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-01-24 07:54:17 | 1. THE EXISTING LIFT STATION NO. 80 LOCATED ALONG | | | NORTHWOOD UNIVERSITY DRIVE LIES PARTIALLY OUTSIDE OF | | | ITS EASEMENT. ADDITIONAL EASEMENT AREA IS NEEDED. | | | 2. THE EXISTING LIFT STATION NO. 98 ALONG THE E-W CANAL | | | WAS PREVIOUSLY BELIEVED TO BE PRIVATE. IN ORDER FOR THE | | | CITY TO OPERATE AND MAINTAIN, AN EASEMENT IS REQUIRED. | | | WE WILL ALSO NEED ANY MISSING EASEMENTS OVER THE | | | EXISTING FORCE MAINS. THIS IS WHY THE OVERALL MASTER | | | WATER AND SEWER PLAN IS REQUIRED. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
11-09-2018 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
11-09-2018 |
Time |
08:18 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2018-11-09 08:21:11 | 1. NEW EASEMENT FOR LIFT STATION IS REQUIRED. | | | 2. METER NEEDS TO BE AT THE RIGHT-OF-WAY LINE. | | | 3. OVERALL MASTER WATER AND SEWER PLANS NEEDS TO BE | | | DEVELOPED SHOWING EXISTING INFRASTRUCTURE AND | | | EASEMENTS. | | | 4. NEED LEVEL OF SERVICE FOR WATER AND SEWER. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
03-22-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-03-22 09:28:31 | PASSED |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
02-20-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-02-20 09:54:31 | 1. REDUCE THE CORNER RADIUS AT THE NORTHWEST CORNER OF | | | MILL'S KEISER WAY/KEISER UNIVERSITY DRIVE AND TIE | | | MILL'S KEISER WAY TO KEISER UNIVERSITY DRIVE | | | PERPENDICULARLY. THIS WILL REDUCE THE SPEED OF TURNING | | | VEHICLES AND PEDESTRIAN CROSSING DISTANCE ACROSS MILL'S | | | KEISER WAY. THE AUTOTURN PATH ON SHEET C-8 SHOWS THAT | | | THE LARGE RADIUS IS NOT NEEDED. CONSIDER ADDING A | | | SIDEWALK AT THE MODIFIED CORNER TO CONNECT THE EXISTING | | | SIDEWALK ON MILL'S KEISER WAY AND KEISER UNIVERSITY | | | DRIVE. | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
01-15-2019 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2019-01-15 15:52:34 | PASSED. | | | | | | SHING TSOI | | | CITY IN-HOUSE TRAFFIC CONSULTANT | | | 561-494-1141 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
11-08-2018 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2018-11-08 14:39:02 | Z18100016 KEISER UNIVERSITY RESIDENCE HALL (OCTOBER 9, | | | 2018 SUBMITTAL) | | | 1. PROVIDE TPS LETTER FROM PALM BEACH COUNTY | | | 2. THE JUSTIFICATION NARRATIVE INDICATES THAT THE | | | MASTER PLAN HAS SEVERAL OTHER CHANGES IN ADDITION TO | | | THE RESIDENCE HALL, BUT IT WASN?T CLEAR WHERE THESE | | | CHANGES ARE. PLEASE INDICATE THE CHANGES ON THE MASTER | | | PLAN. | | | 3. SINCE THE PEDESTRIAN PATHWAYS WILL BE SHARED BETWEEN | | | PEDESTRIANS AND BICYCLES, PROVIDE PEDESTRIAN PATHWAYS | | | WITH A MINIMUM WIDTH OF 8 FEET, 12 FEET PREFERRED, | | | SURROUNDING THE PROPOSED RESIDENCE HALL, INCLUDING THE | | | EXISTING PATHWAY AT THE BACK OF THE RESIDENCE HALL. | | | 4. PROVIDE A ?KEEP RIGHT? SIGN (R4-7 OR R4-7B) AT THE | | | SOUTHEAST CORNER OF THE CENTER ISLAND FACING WESTBOUND | | | VEHICLES. | | | 5. USE RAISED ISLAND INSTEAD OF STRIPING AT THE | | | SOUTHEAST CORNER OF THE CENTER ISLAND, AND USE | | | MOUNTABLE CURB AS NEEDED TO ACCOMMODATE TRUCK MOVEMENTS | | | AT THAT CORNER. | | | 6. THE DIAGONAL MARKINGS FOR THE FIRE LANE SHOULD BE | | | SLANTED AWAY FROM THE CURB. | | | 7. CONSIDER PROVIDING PEDESTRIAN AND BICYCLE | | | CONNECTIONS TO VILLAGE BOULEVARD AT THE NORTH AND SOUTH | | | END OF THE CAMPUS. AT THE NORTH END, CONSIDER PROVIDING | | | A PEDESTRIAN/BICYCLE BRIDGE ACROSS THE CANAL, AND | | | SIDEWALK CONNECTION TO THE EXISTING SIDEWALK ON VILLAGE | | | BOULEVARD. AT THE SOUTH END, IN ADDITION TO THE | | | EXISTING PEDESTRIAN ACCESS POINT, CONSIDER PROVIDING A | | | SEPARATE BICYCLE PATH THROUGH THE FPL EASEMENT AND | | | PROPERTY TO CONNECT TO THE EXISTING PATHWAY AROUND THE | | | LAKE TO THE EAST. THESE CONNECTIONS COULD POTENTIALLY | | | REDUCE THE CYCLING DISTANCE BETWEEN VILLAGE BOULEVARD | | | AND THE CAMPUS FROM OVER 8,800 FEET AND WALKING | | | DISTANCE FROM OVER 2,500 FEET TO LESS THAN 750 FEET, AS | | | WELL AS ELIMINATING THE EXPOSURE OF HIGH SPEED VEHICLES | | | TO STUDENTS ON BICYCLES. | | | | | | ERIK D. FERGUSON, P.E. | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
03-18-2019 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
03-18-2019 |
Time |
12:49 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
03-18-2019 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
03-05-2019 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
03-05-2019 |
Time |
14:48 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
03-05-2019 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2019-03-05 14:48:53 | CASE NO. PB 1069Z - 2ND RESUBMITTAL | | | KEISER UNIVERSITY DORMS | | | 2600 NORTH MILITARY TRAIL | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN | | | (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - THE COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND | | | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON MONDAY, | | | MARCH 11, 2019, TO BE ELIGIBLE TO BE SCHEDULED FOR THE | | | APRIL 16, 2019 PLANNING BOARD MEETING. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE COMMENTS WITHIN 60 DAYS FROM | | | THE DATE OF THESE COMMENTS (BY MAY 5, 2019), THE CASE | | | SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL | | | REQUIRE A NEW DEVELOPMENT APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) ONE | | | ADDITIONAL RESUBMITTAL AT NO ADDITIONAL COST. IF | | | PREVIOUSLY-ISSUED COMMENTS CONTINUE TO NOT BE | | | SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE ASSESSED | | | A RESUBMITTAL FEE. SUCH FEE WILL BE 20% OF THE ORIGINAL | | | APPLICATION FEE ($600). | | | | | | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | 1) PLEASE VERIFY THE ORIENTATION OF THE PRESS BOX | | | STAIRS. THE PERMIT DRAWINGS HAD THE STAIRS LOCATED ON | | | THE NORTH SIDE OF THE PRESS BOX. | | | | | | 2) REVISED COMMENT: PLEASE CHECK THE MATH ON THE | | | PARKING TABLE: | | | | | | A. STAFF HAS ADDED THE LISTED NUMBER OF PARKING SPACES | | | IN EACH PARKING FIELD AND IT TOTALS 1,087, NOT THE | | | 1,089 LISTED ON THE "PROVIDED" LINE OF THE PARKING | | | TABLE ON SHEET MP.1. | | | B. STAFF ADDED ALL THE AREAS LISTED AS "EXISTING | | | PARKING" AND IT TOTALS 585, NOT 589. | | | C. THE RESIDENCE HALL LINE ONLY LISTS 23, NOT THE 25 | | | PROVIDED PARKING SPACES. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
01-23-2019 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
01-23-2019 |
Time |
11:45 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
01-23-2019 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2019-01-23 11:45:47 | CASE NO. PB 1069Z - 1ST RESUBMITTAL | | | KEISER UNIVERSITY DORMS | | | 2600 NORTH MILITARY TRAIL | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN | | | (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - THE COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND | | | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY, | | | FEBRUARY 8, 2018, TO BE ELIGIBLE TO BE SCHEDULED FOR | | | THE MARCH 19, 2019 PLANNING BOARD MEETING. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE COMMENTS WITHIN 60 DAYS FROM | | | THE DATE OF THESE COMMENTS (BY MARCH 23, 2019), THE | | | CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER ACTION | | | SHALL REQUIRE A NEW DEVELOPMENT APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) ONE | | | ADDITIONAL RESUBMITTAL AT NO ADDITIONAL COST. IF | | | PREVIOUSLY-ISSUED COMMENTS CONTINUE TO NOT BE | | | SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE ASSESSED | | | A RESUBMITTAL FEE. SUCH FEE WILL BE 20% OF THE ORIGINAL | | | APPLICATION FEE ($600). | | | | | | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | GENERAL | | | | | | 1) SHEET A10.1 LISTS THE CHILLER AS BEING 8 FEET IN | | | HEIGHT. THE SCREEN WALL SHOWN ON SHEET A1.2 IS ONLY 7 | | | FEET 4 INCHES IN HEIGHT AND THE GATE SHOWN ON SHEET | | | A10.1 IS ONLY 7 FEET IN HEIGHT. THE FULL HEIGHT OF THE | | | MECHANICAL EQUIPMENT NEEDS TO BE SCREENED. | | | | | | 2) THE SCALE SHOWN ON SHEETS C-5 AND C-7 ARE INCORRECT. | | | THESE PLANS ARE DRAWN AT 1:30. | | | | | | PARKING | | | | | | 3) THE TWO PARKING SPACES THAT WERE REMOVED SOUTH OF | | | BUILDING #3 WERE NOT REMOVED FROM THE ?PROVIDED? LINE | | | OF THE PARKING TABLE ON SHEET MP.1. | | | | | | 4) THE TAG SHOWING THE NUMBER OF SPACES IN THE PARKING | | | ROW IMMEDIATELY SOUTH OF BUILDING #3 INCORRECTLY SHOWS | | | A "7" ON SHEET MP.5 INSTEAD OF THE PROVIDED SIX PARKING | | | SPACES. PLEASE NOTE THAT THE OTHER PARKING BAYS IN THIS | | | AREA NEED TO INCLUDE THE NUMBER OF PARKING SPACE TAGS. | | | | | | 5) STAFF COMMENTED THAT HAVING WHEEL STOPS AND D CURBS | | | IS REDUNDANT FOR PARKING SPACES AND RECOMMENDED USING | | | JUST THE D CURB, WITH A TWO FOOT OVERHANG. THIS | | | REQUIRES THAT THE D CURB BE INSTALLED SUCH THAT THE | | | ENTRANCE TO THE PARKING SPACE TO THE FACE OF THE D CURB | | | IS 16 FEET AND THEN THE TWO FOOT OVERHANG GIVES THE | | | MINIMUM 18 FOOT DEPTH PARKING SPACE. IF YOU PUT 18 OR | | | 19 FEET OF PAVED PARKING STALL DEPTH, YOU MUST USE A | | | WHEEL STOP, REGARDLESS OF THE CURB AS THE REQUIRED TWO | | | FOOT OVERHANG IS NOT PROVIDED - THERE IS LANDSCAPE AND | | | SIDEWALK AT THE END OF YOUR SPACES THAT MAY NOT BE | | | OVERHUNG. | | | | | | 6) A FEW OF THE DIMENSION TAGS ON SHEET MP.5 DO NOT | | | ALIGN WITH WHAT THEY ARE DIMENSIONING. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
11-13-2018 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
11-13-2018 |
Time |
17:28 |
Rev Time |
2.50 |
| Received By |
eschneid |
Date |
11-13-2018 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2018-11-13 17:32:49 | CASE NO. PB 1069Z | | | KEISER UNIVERSITY DORMS | | | 2600 NORTH MILITARY TRAIL | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN | | | (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND | | | SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY, | | | NOVEMBER 30, 2018, TO BE ELIGIBLE TO BE SCHEDULED FOR | | | THE JANUARY 15, 2019 PLANNING BOARD MEETING. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS | | | FROM THE DATE OF THE PPRC MEETING (BY JANUARY 14, | | | 2019), THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY | | | FURTHER ACTION SHALL REQUIRE A NEW DEVELOPMENT | | | APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($600). | | | | | | - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED | | | IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION | | | 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | GENERAL | | | | | | 1) THERE IS A DISCREPANCY BETWEEN THE JUSTIFICATION | | | STATEMENT/TRAFFIC STATEMENT AND THE PLANS. IS IT 200 OR | | | 208 BEDS? | | | | | | 2) PLEASE CONSIDER INSTALLING SOLAR OR GREEN ROOF | | | INSTALLATION ON THE ROOF OF THE PROPOSED DORMS. | | | | | | 3) PROVIDE DETAILS OF THE MECHANICAL EQUIPMENT SCREEN | | | WALL. | | | | | | PARKING | | | | | | 4) THE PLANS INCLUDE A TAG FOR THE FUTURE LOCATION OF A | | | PARKING STRUCTURE (#22). PLEASE NOTE THAT THE PARKING | | | STRUCTURE MAY NOT BE BUILT ON THE 100 FOOT FPL | | | EASEMENT, WHICH HAS MAJOR OVERHEAD POWER LINES. WAS THE | | | #22 TAG SUPPOSED TO BE ON THE WEST SIDE OF THE FPL | | | EASEMENT WHERE THERE IS ROOM TO CONSTRUCT A PARKING | | | STRUCTURE? | | | | | | 5) THE PARKING SPACE TAGS SOUTH OF BUILDING #3 AND EAST | | | OF THE DORMS ARE CONFUSING AS THEY OVERLAP THE TWO | | | AREAS. AS THIS WILL BE THE PLAN OF RECORD, JUST INCLUDE | | | THE FINAL NUMBER OF SPACES IN THIS AREA - 26 (18 | | | SPACES/8 HC). | | | | | | 6) PROVIDE DETAILS OF THE FLUSH HEADER CURBS AND THE | | | DROP CURB (VALLEY GUTTER). | | | | | | 7) THE PLANS SHOW A D CURB AT THE HEAD OF ALL THE | | | PARKING SPACES. THE PARKING DETAIL SHOWS THE USE OF | | | WHEEL STOPS. IT IS REDUNDANT TO USE BOTH. PLEASE | | | CONSIDER PROVIDING A TWO FOOT OVERHANG OF THE D CURB TO | | | PROVIDE MORE PERVIOUS AREA. | | | | | | BICYCLE PARKING | | | | | | 8) PLEASE CONSIDER INSTALLING ADDITIONAL BICYCLE AT THE | | | LOCATION OF THE DORMS. EIGHT BICYCLE RACKS FOR 208 | | | STUDENTS IS A VERY LOW NUMBER. ADDITIONALLY, PLEASE | | | CONSIDER HAVING SOME OF THE BICYCLE RACKS UNDER COVER. | | | | | | 9) UPDATE SHEET C-2 TO STATE THAT EIGHT BICYCLE PARKING | | | SPACES ARE PROVIDED (4 RACKS X 2 SPACES) AND THE | | | PARKING TABLE ON SHEET MP.1 (64 PROVIDED). IF | | | ADDITIONAL SPACE ARE PROVIDED BASED ON COMMENT #8 | | | ABOVE, PLEASE UPDATE THE PLANS ACCORDINGLY. | | | | | | 10) PROVIDE THE DIMENSIONS OF THE BICYCLE RACK PAD ON | | | THE SITE PLAN (SHEET C-2). | | | | | | SIDEWALKS | | | | | | 11) WIDEN THE SIDEWALKS AROUND THE DORMS TO A UNIFORM | | | EIGHT FEET IN WIDTH AS THIS WILL BE A HEAVY PEDESTRIAN | | | USE AREA. | | | | | | 12) PROVIDE A CONTINUOUS SIDEWALK ON THE SOUTH SIDE OF | | | THE ENTRY DRIVE FROM THE DORMS TO THE SIDEWALK ADJACENT | | | TO UNIVERSITY DRIVE (NORTH SIDE OF THE CANAL). THIS | | | SIDEWALK CONNECTION WOULD BE AN ALMOST DIRECT ROUTE TO | | | THE PEDESTRIAN ACCESS WAY TO THE VILLAGE COMMONS | | | SHOPPING CENTER. | | | | | | DUMPSTER | | | | | | 13) PROVIDE THE DIMENSIONS OF THE GARBAGE ENCLOSURE ON | | | THE PLANS. IT DOES NOT APPEAR TO CONFORM TO THE MINIMUM | | | CITY STANDARDS. | | | | | | 14) PROVIDE A DETAIL OF THE ENCLOSURE WALLS. | | | | | | 15) PLEASE CONSIDER RECYCLING FACILITIES FOR THE DORMS. | | | |
|
|
| |