Plan Review Details - Project Z18080013
| Plan Review Stops For Project Z18080013 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
09-24-2018 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
09-24-2018 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
09-24-2018 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2018-09-24 19:14:57 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | | | | BUILDING A | | | | | | NO SITE PLAN COMMENTS ON THE PROPOSED CHANGES TO | | | BUILDING A. | | | | | | | | | BUILDING D | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 3. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 4. BUILDING ADDRESS. WHEN THE BUILDING PERMIT | | | APPLICATION IS SUBMITTED, EACH SEPARATE BUILDING, AND | | | UNIT WITH AN INDEPENDENT ENTRANCE FROM THE STREET, | | | SHALL HAVE A SEPARATE ADDRESS. FOR STREET ADDRESSING, | | | CONTACT MICHAEL ORIO, GIS SUPPORT SPECIALIST, AT (561) | | | 494 1080, OR BY EMAIL: [email protected] | | | | | | 5. ART IN PUBLIC PLACES. IF THE TOTAL PROJECTVALUE | | | (INCLUDING DESIGN FEES, CONSTRUCT COSTS, OVERHEADS, AND | | | PROFIT) EXCEEDS $750,000, THE PROJECT WILL BE SUBJECT | | | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
08-30-2018 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
08-30-2018 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
08-30-2018 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2018-08-30 15:22:21 | AFTER A REVIEW OF THE PPRC RESPONSE MEMO FROM ERIC | | | SCHNEIDER, PRINCIPLE PLANNER, AND THE ATTACHED | | | DOCUMENTS DATED AUGUST 28, 2018, FROM URBAN DESIGN | | | KILDAY STUDIOS, ANY FIRE PREVENTION BUREAU CONCERNS | | | APPEAR TO HAVE BEEN ADDRESSED. | | | | | | HOWEVER, THE BUREAU'S APPROVAL OF THIS SUBMITTED | | | PROJECT DOES NOT CONSTITUTE ITS FINAL REVIEW OR | | | APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
10-16-2018 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-16-2018 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-16-2018 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2018-10-16 14:53:09 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: PB OUTLETS BLDG D Z18080013 | | | OCTOBER 12, 2018 | | | STAFF HAS REVIEWED THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS FOR THE ABOVE REFERENCED PETITION AND | | | PROVIDES THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. CAN BE PROVIDED ON A SEPARATE | | | SHEET. | | | | | | 2. SATISFIED. SHOW COMPLIANCE WITH THE FLORIDA FRIENDLY | | | LANDSCAPE SECTION 94-446 (G) AND PROVIDE 50 POINTS FROM | | | THE DESIGN OPTIONS CHART FOR THE AFFECTED AREA. CAN BE | | | PROVIDED ON A SEPARATE SHEET. | | | | | | 3. CONDITIONALLY SATISFIED. PROVIDE A MORE ACCURATE | | | LOCATION FOR THE UTILITY AFFECTING THE RELOCATION OF | | | THE DATE PALMS. LOCATES CAN BE DONE AHEAD OF TIME TO | | | ASSURE THERE WILL NOT BE CHANGES TO THE LOCATIONS, AS | | | THESE PALMS ARE AN INTEGRAL PART OF THE LANDSCAPE | | | BUFFER BORDERING PB LAKES BLVD. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. THE LANDSCAPE PERMIT SHALL SHOW THE FINAL CONDITION | | | OF THE BUFFER PLANTINGS AFTER DETERMINATION OF ANY | | | CONFLICTS WITH THE MEDJOOL DATE PALMS. IF THE PALMS | | | HAVE TO BE RELOCATED FARTHER SOUTH IN THE BUFFER THEY | | | SHALL BE REPLACED WITH BUFFER TREES MEETING THE CODE | | | REQUIREMENTS. A NOTE HAS BEEN INCLUDED ON SHEET LP-7 OF | | | THE LANDSCAPE PLANS. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
09-13-2018 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
09-13-2018 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
09-13-2018 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2018-09-13 12:41:40 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: PB OUTLETS BLDG D Z18080013 | | | SEPTEMBER 13, 2018 | | | STAFF HAS REVIEWED THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS FOR THE ABOVE REFERENCED PETITION AND | | | PROVIDES THE FOLLOWING COMMENTS: | | | | | | 1. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | | LANDSCAPES. CAN BE PROVIDED ON A SEPARATE SHEET. | | | | | | 2. SHOW COMPLIANCE WITH THE FLORIDA FRIENDLY LANDSCAPE | | | SECTION 94-446 (G) AND PROVIDE 50 POINTS FROM THE | | | DESIGN OPTIONS CHART FOR THE AFFECTED AREA. CAN BE | | | PROVIDED ON A SEPARATE SHEET. | | | | | | 3. PROVIDE A MORE ACCURATE LOCATION FOR THE UTILITY | | | AFFECTING THE RELOCATION OF THE DATE PALMS. LOCATES CAN | | | BE DONE AHEAD OF TIME TO ASSURE THERE WILL NOT BE | | | CHANGES TO THE LOCATIONS, AS THESE PALMS ARE AN | | | INTEGRAL PART OF THE LANDSCAPE BUFFER BORDERING PB | | | LAKES BLVD. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
P |
Date |
10-16-2018 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
10-16-2018 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
10-16-2018 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2018-10-16 10:49:03 | STORMWATER COMMENTS SATISFIED. |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
09-12-2018 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
09-12-2018 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
09-12-2018 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2018-09-12 13:25:48 | THE COMMENTS BELOW ARE FROM THE REVIEW OF THE AUGUST | | | 28, 2018 REVIEW PACKAGE: | | | | | | 1. TOP PORTION OF SHEET C-500 MISSING. | | | | | | 2. PROVIDE VERTICAL DATUM ON ALL SHEETS (I.E. C-400, | | | C-500, C-600) THAT SHOW ELEVATIONS. IF VERTICAL DATUM | | | IS NOT NGVD 1929 THEN A CONVERSION EQUATION TO | | | CALCULATE NGVD 1929 ELEVATIONS SHALL ALSO BE PROVIDED. | | | | | | TRACY L. WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
10-16-2018 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
10-16-2018 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
10-16-2018 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
09-24-2018 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
09-24-2018 |
Time |
15:03 |
Rev Time |
1.50 |
| Received By |
eschneid |
Date |
09-24-2018 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2018-09-24 15:04:06 | CASE NO. PB 891GG | | | PALM BEACH OUTLETS BUILDING D ATM | | | 1820 PALM BEACH LAKES BOULEVARD | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR | | | (4) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT | | | OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS | | | FROM THE DATE OF THESE COMMENTS (BY NOVEMBER 24, 2018), | | | THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER | | | ACTION SHALL REQUIRE A NEW DEVELOPMENT APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($60). | | | | | | 1) IT VISUALLY APPEARS THAT THERE IS MORE IMPERVIOUS | | | SURFACE ON THE NEW PLAN DUE TO THE ADDITION OF THE ATM | | | ACCESS DRIVE REPLACING AN AREA THAT PREVIOUSLY HAD | | | LANDSCAPE. THE NEW DRIVEWAY BEHIND BUILDING A ALSO ADDS | | | IMPERVIOUS AREA. THE DEVELOPMENT CRITERIA TABLE DID NOT | | | CHANGE FOR IMPERVIOUS AREA OR LANDSCAPE PERCENTAGE. THE | | | JUSTIFICATION STATEMENT STATES THAT THERE IS NO CHANGE | | | TO THE PERCENTAGES. IS THIS DUE TO THE SMALL AMOUNT OF | | | CHANGE VS THE OVERALL SITE? ARE YOU KEEPING TRACK OF | | | THE CUMULATIVE CHANGES? NOTE THAT THE SITE IS GETTING | | | CLOSE TO THE 85/15% BALANCE POINT. | | | | | | 2) PLEASE CLARIFY WHY THE PBA #4 PARKING SF FOR CURRENT | | | APPLICATION IS ONLY 10 SF MORE THAN WHAT WAS APPROVED | | | AS PART OF PB 891FF (CFA AND TOO JAY'S MINOR) WHEN THE | | | NEW BUILDING D IS 17 SF FEET LARGER THAN THE PREVIOUS | | | ONE. THE NUMBER OF REQUIRED PARKING SPACES IS NOT | | | AFFECTED. | | | | | | 3) THERE IS A STRIPED AREA IN THE RECONFIGURED PARKING | | | WEST OF BUILDING D. WHY IS THIS NOT USED TO EXPAND THE | | | ADJACENT TERMINAL LANDSCAPE ISLAND OR TO SHIFT THE | | | ENTIRE PARKING ROW SOUTH AND THEN EXPAND THE TERMINAL | | | LANDSCAPE ISLAND ON THE OTHER END OF THE PARKING ROW? | | | | | | 4) THE ELEVATIONS ON SHEET A.100 ARE MISLABELED WHEN | | | COMPARED TO THE FLOOR PLAN ON SHEET A.200. | | | | | | 5) THE PALM BEACH LAKES ELEVATION MUST BE CLEARLY | | | LABELED ON SHEET A.100. | | | | | | 6) PLEASE PROVIDE ONE ADDITIONAL COPY OF THE MASTER | | | PLAN. | | | | | | |
|
|
| |
Print |
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |