Plan Review Details - Project Z18070013
| Plan Review Stops For Project Z18070013 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
08-07-2018 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
08-07-2018 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
08-07-2018 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2018-08-07 18:42:27 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. FLOOD ZONE. ACCORDING TO THE ADOPTED FLOOD INSURANCE | | | RATE MAPS (FIRMS), THE PROPOSED BUILDING IS IN FLOOD | | | ZONE AE, WITH A BASE FLOOD ELEVATION OF 12.7 FT NAVD. | | | THE FIRST FLOOR OF THE BUILDING AND ALL ASSOCIATED | | | MECHANICAL EQUIPMENT (CHILLERS, GENERATORS ETC.) SHALL | | | BE 24 INCHES (FREEBOARD) ABOVE THE BASE FLOOD | | | ELEVATION. | | | | | | 3. VAN ACCESSIBLE PARKING SPACES. PER SECTION 208.2.4 | | | OF FLORIDA ACCESSIBILITY CODE, ONE IN EVERY SIX | | | REQUIRED ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING | | | STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND DESIGNED IN | | | ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY | | | CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT | | | SPACE AND VEHICULAR ACCESS ROUTE). THE PLANS SHALL SHOW | | | AT LEAST TWO VAN ACCESSIBLE PARKING SPACES WHEN | | | SUBMITTED FOR PERMIT. | | | | | | 4. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE. | | | | | | 5. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND | | | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF | | | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE | | | VERIFIED. | | | | | | 6. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES | | | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO | | | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL | | | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE | | | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED | | | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR | | | OTHER APPROVED METHODS. | | | | | | 7. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 8. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT | | | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE | | | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
08-08-2018 |
|
|
Cont ID |
|
| Sent By |
RRossano |
Date |
08-08-2018 |
Time |
|
Rev Time |
1.00 |
| Received By |
|
Date |
08-07-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-08-08 07:16:41 | 1500 CENTREPARK | | | PROVIDE INDIVIDUAL SERVICE TAPS FOR DOMESTIC WATER AND | | | FIRE WATER SERVICE. | | | PROVIDE GPD DEMANDS FOR WATER AND SEWER. | | | PROVIDE VIDEO OF SANITARY SEWER MAIN. | | | PROVIDE HYDRANT FLOW TEST. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
10-01-2018 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
10-01-2018 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
10-01-2018 |
Time |
12:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
08-03-2018 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
08-03-2018 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
08-03-2018 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2018-08-03 13:53:31 | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. ALL PARKING STRUCTURES SHALL COMPLY WITH NFPA 88A, | | | PARKING STRUCTURES AND NFPA 101, THE LIFE SAFETY CODE, | | | INCLUDING MORE SPECIFICALLY, CHAPTER 42 STORAGE | | | OCCUPANCIES (PARKING STRUCTURES) | | | | | | 7. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA | | | 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS | | | STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE | | | BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE | | | BEING CONSTRUCTED. | | | SEPARATE SHOP DRAWINGS, ARE REQUIRED TO BE SUBMITTED, | | | REVIEWED AND APPROVED BY THE FIRE PREVENTION BUREAU | | | PRIOR TO ANY INSTALLATION. HIGH RISES SHALL HAVE TWO | | | SEPARATE SOURCES OF WATER SUPPLY. | | | 6.4.5.4* FIRE DEPARTMENT CONNECTIONS SHALL BE LOCATED | | | NOT MORE THAN 100 FT (30.5 M) FROM THE NEAREST FIRE | | | HYDRANT CONNECTED TO AN APPROVED WATER SUPPLY. | | | 18.3 WATER SUPPLIES. | | | 18.3.1* AN APPROVED WATER SUPPLY CAPABLE OF SUPPLYING | | | THE REQUIRED FIRE FLOW FOR FIRE PROTECTION SHALL BE | | | PROVIDED TO ALL PREMISES UPON WHICH FACILITIES, | | | BUILDINGS, OR PORTIONS OF BUILDINGS ARE HEREAFTER | | | CONSTRUCTED OR MOVED INTO THE JURISDICTION. THE | | | APPROVED WATER SUPPLY SHALL BE IN ACCORDANCE WITH | | | SECTION 18.4. | | | PER NFPA 14 SECTION 7.12.2, HIGH-RISE BUILDINGS SHALL | | | HAVE AT LEAST TWO REMOTELY LOCATED FIRE DEPARTMENT | | | CONNECTIONS FOR EACH ZONE. | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | 8. A CLASS ?A? NFPA 72 COMPLIANT MONITORED FIRE ALARM | | | SYSTEM IS REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP | | | DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED AND | | | APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY | | | INSTALLATION. | | | | | | 9. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM. | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER?S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | 12. COMMAND ROOM | | | THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | A. SHALL BE A MINIMUM OF 200 FT SQUARED WITH A MINIMUM | | | DIMENSION OF 10 FT. | | | B. THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | C. A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | D. SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS AND THE LOCATION | | | OF FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS | | | E. A WORK TABLE. | | | F. IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | G. THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | H. ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION OF | | | THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | I. STATUS INDICATORS AND CONTROLS FOR AIR DISTRIBUTION | | | SYSTEMS. | | | J. CONTROLS FOR UNLOCKING STAIRWAY DOORS SIMULTANEOUSLY | | | K. SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | L. EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | M. FIRE PUMP STATUS INDICATORS | | | N. GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | O. PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | P. CONTROLS REQUIRED FOR SMOKE CONTROL | | | Q. ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1. | | | R. ELEVATOR EMERGENCY OR STANDBY POWER SELECTOR | | | SWITCH(ES), WHERE EMERGENCY OR STANDBY POWER IS | | | PROVIDED | | | | | | 13. RADIO | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | NFPA 72, 24.5.2* TWO-WAY RADIO COMMUNICATIONS | | | ENHANCEMENT SYSTEMS. | | | 24.5.2.2 RADIO COVERAGE. RADIO COVERAGE SHALL BE | | | PROVIDED THROUGHOUT THE BUILDING AS A PERCENTAGE OF | | | FLOOR AREA AS SPECIFIED IN 24.5.2.2.1 THROUGH | | | 24.5.2.2.3. | | | 24.5.2.2.1 CRITICAL AREAS. CRITICAL AREAS, SUCH AS THE | | | EMERGENCY COMMAND CENTER(S), THE FIRE PUMP ROOM(S), | | | EXIT STAIRS, EXIT PASSAGEWAYS, ELEVATOR LOBBIES, | | | STANDPIPE CABINETS, SPRINKLER SECTIONAL VALVE | | | LOCATIONS, AND OTHER AREAS DEEMED CRITICAL BY THE | | | AUTHORITY HAVING JURISDICTION, SHALL BE PROVIDED WITH | | | 99 PERCENT FLOOR AREA RADIO COVERAGE. | | | 24.5.2.2.2 GENERAL BUILDING AREAS. GENERAL BUILDING | | | AREAS SHALL BE PROVIDED WITH 90 PERCENT FLOOR AREA | | | RADIO COVERAGE. | | | 24.5.2.3 SIGNAL STRENGTH. | | | 24.5.2.3.1 INBOUND. A MINIMUM INBOUND SIGNAL STRENGTH | | | OF -95 DBM, OR OTHER SIGNAL STRENGTH AS REQUIRED BY THE | | | AUTHORITY HAVING JURISDICTION, SHALL BE PROVIDED | | | THROUGHOUT THE COVERAGE AREA. | | | 24.5.2.3.2 OUTBOUND. A MINIMUM OUTBOUND SIGNAL STRENGTH | | | OF -95 DBM AT THE DONOR SITE, OR OTHER SIGNAL STRENGTH | | | AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION, SHALL | | | BE PROVIDED FROM THE COVERAGE AREA. | | | | | | THE SYSTEM SHALL MAINTAIN A MINIMUM RADIO SIGNAL | | | STRENGTH OF -95 DBM FOR THE RADIO SYSTEM USED BY WEST | | | PALM BEACH FIRE RESCUE. TESTING SHALL BE BY AN | | | ACCEPTABLE NATIONAL STANDARD DOCUMENTING PERCENTAGES | | | NOTED ABOVE AND BY ACTUAL RADIO TESTING BY FIRE | | | PERSONNEL. IF THE MINIMUM CANNOT BE MAINTAINED, A | | | BI-DIRECTIONAL AMPLIFIED SYSTEM SHALL BE INSTALLED WITH | | | A MINIMUM 2-HOUR RUN TIME BATTERY BACK-UP. | | | | | | 14. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | | BUILDING. | | | ANY GATES SHALL BE PROVIDED WITH KNOX KEY ACCESS LOCKS, | | | PADLOCKS AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 15. THE SMOKE CONTROL SYSTEM SHALL COMPLY WITH NFPA | | | 101, CHAPTER 9, BUILDING SERVICE AND FIRE PROTECTION | | | EQUIPMENT, INCLUDING: | | | THE SMOKE CONTROL SYSTEMS SHALL BE INSTALLED, | | | INSPECTED, TESTED, AND MAINTAINED IN ACCORDANCE WITH | | | NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS; NFPA 204, | | | STANDARD FOR SMOKE AND HEAT VENTING; OR NATIONALLY | | | RECOGNIZED STANDARDS, ENGINEERING GUIDES, OR | | | RECOMMENDED PRACTICES, AS APPROVED BY THE AUTHORITY | | | HAVING JURISDICTION. | | | THE ENGINEER OF RECORD SHALL CLEARLY IDENTIFY THE | | | INTENT OF THE SYSTEM, THE DESIGN METHOD USED, THE | | | APPROPRIATENESS OF THE METHOD USED, AND THE REQUIRED | | | MEANS OF INSPECTING, TESTING, AND MAINTAINING THE | | | SYSTEM. | | | ACCEPTANCE TESTING SHALL BE PERFORMED BY A SPECIAL | | | INSPECTOR IN ACCORDANCE WITH SECTION 9.9. | | | | | | 16. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 17. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
12-06-2018 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
12-06-2018 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
12-06-2018 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2018-12-06 10:26:15 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: CENTREPARK CPD RESIDENTIAL Z18070013 | | | DECEMBER 6, 2018 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. THERE ARE CORRECTIONS TO BE MADE TO THE | | | TREE DISPOSITION PLAN SHEET TD-1: | | | ? SATISFIED. SECTION 94-448 (D)(3) REQUIRES ALL NATIVE | | | TREES AND PALMS IN GOOD CONDITION TO BE PRESERVED OR | | | RELOCATED. THE 19 ROYAL PALMS CAN BE RELOCATED ON SITE, | | | WITHIN THE CENTREPARK CPD, OR THE CITY HAS MANY | | | LOCATIONS WITHIN PUBLIC RIGHT OF WAYS FOR RELOCATION. | | | ? SATISFIED. CORRECT THE PROVIDED MITIGATION CHART FOR | | | REPLACEMENT <20?SPREAD TOTAL TO 3,800 | | | ? SATISFIED. CORRECT THE REQUIRED MITIGATION TO 200 | | | TOTAL FOR LIGUSTRUMS | | | | | | 2. CONDITIONALLY SATISFIED. UPDATE THE FLORIDA FRIENDLY | | | LANDSCAPE DESIGN OPTIONS CHART TO CURRENT CODE SECTION | | | 94-446 (G) FOR ALL OPTIONS UNDER (3) GROUNDCOVER OR | | | GRASS. | | | THERE ARE CORRECTIONS NEEDED TO THE WORDING IN (3)(A) | | | AND (3)(B), (4)(A) AND (4)(B), (5)(A) AND (5)(B). | | | PLEASE REVISE. OPTIONS TAKEN NEED TO BE REVISED. | | | | | | 3. SATISFIED. PROVIDE THE PLANT LIST, LANDSCAPE | | | REQUIREMENTS, OVERALL LANDSCAPE REQUIREMENTS, AND | | | LANDSCAPE NOTES ON ONE SHEET ONLY. LANDSCAPE PLAN CAN | | | THEN BE CONSOLIDATED ONTO TWO SHEETS. | | | | | | 4. SATISFIED. REVISE THE PLANT LIST TO ADD A COLUMN FOR | | | FLORIDA NATIVE PLANTS AND FOR DROUGHT TOLERANCE LEVEL | | | FOR EACH SPECIES FOR CLARITY. | | | | | | 5. SATISFIED. ON THE LANDSCAPE REQUIREMENTS CHART, | | | CORRECT THE SITE LANDSCAPE CALCULATIONS TO SHOW THE | | | SHADE TREE AND FLOWERING TREE CALCULATIONS AND ADD THE | | | ONE TREE PER UNIT REQUIRED PER SECTION 94-443 (D)(2)A. | | | TO ACHIEVE THE TOTAL REQUIRED TREE COUNT OF 285. | | | CORRECT THE PROVIDED TOTAL TREES TO 68, AS ANY PALMS | | | EXCEPT THE ROYALS COUNT AS 3 TO 1 FOR SUBSTITUTION FOR | | | REQUIRED TREES. STAFF SUGGESTS THAT ONCE CORRECTIONS | | | AND CALCULATIONS ARE FINALIZED, THE DEFICIENCY OF TREES | | | REQUESTED THROUGH THE WAIVER PROCESS MAY BE ADDRESSED | | | THROUGH IN LIEU MITIGATION AS PROVIDED IN SECTION | | | 94-448 (E)(2), OR POSSIBLE PLANTING OF TREES WITHIN THE | | | CENTREPARK CPD. | | | | | | REQUIRED ON SITE TREES ARE 39, MULTIFAMILY 242 EQUALS | | | 285. | | | | | | 6. SATISFIED. SHOW THE PERCENTAGE OF PALMS SUBSTITUTED | | | FOR REQUIRED TREES NOT EXCEEDING 35 PERCENT PER SECTION | | | 94-442(D) FOR THE TREES PROPOSED WITH THIS PLAN. | | | | | | 7. SATISFIED. CORRECT THE CALCULATIONS FOR THE NORTH | | | BUFFER TO 7. INCLUDE CALCULATIONS FOR THE SOUTH | | | REQUIRED BUFFER. | | | | | | | | | 8. SATISFIED. SHOW THE LOCATIONS OF ALL LANDSCAPE | | | BUFFERS ON THE LANDSCAPE AND SITE PLAN. THE SOUTH | | | PROPERTY LINE REQUIRES A 5 FOOT BUFFER. | | | | | | | | | 9. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | | | | 10. SATISFIED. PLEASE SHOW LOCATIONS OF WATER, SEWER, | | | FIRE LINES, DRAINAGE LINES AND FPL TRANSFORMERS ON THE | | | LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH LANDSCAPING. | | | | | | 11. SATISFIED. PROVIDE SCREENING FOR ALL GROUND MOUNTED | | | VALVES AND EQUIPMENT. | | | | | | 12. SATISFIED. SHOW THE LOCATIONS OF ALL SITE LIGHTING | | | ON THE LANDSCAPE PLAN AND RESOLVE ANY CONFLICTS WITH | | | TREES. | | | | | | THIS MAY BE PROPOSED AS A CONDITION OF APPROVAL. | | | ADDITIONAL COMMENTS 10/5/18: | | | | | | 13. SATISFIED. TREE #45 MUST BE INCLUDED IN MITIGATION | | | DUE IF IT IS TO BE REMOVED. REVISE TREE DISPOSITION | | | LIST TO SHOW 300 MITIGATION REQUIRED AND REMOVE AS | | | DISPOSITION. | | | | | | 14. SATISFIED. JUSTIFICATION FOR WAIVER OF 143 TREES | | | NEEDS TO BE CLARIFIED TO PROVIDE THE COMPARATIVE VALUE | | | FOR THE NUMBER OF TREES PROVIDED AND PROPOSE A | | | COMPARATIVE VALUE FOR THE INCREASED TREE SIZES. | | | | | | 15. SATISFIED. THE PLAZA AREA PLANTING PROPOSED DOES | | | NOT PROVIDE ANY TREE CANOPY OR SHADE IN THE PEDESTRIAN | | | AREAS AND DOES NOT PROVIDE ANY REASON FOR PEDESTRIAN | | | ACCESS FROM THE PUBLIC SIDEWALK. TREE CANOPY AND SHADE | | | IS NOT PROVIDED FOR THE SIDEWALK ALONG AUSTRALIAN | | | AVENUE. THIS DOES NOT ACCOMPLISH THE PEDESTRIAN | | | FRIENDLY EXPERIENCE THE CITY IS TRYING TO CREATE. | | | | | | RESOLUTION NO. 97-17 | | | | | | 16. SATISFIED. PER EXHIBIT F, APPROVAL FROM THE | | | ARCHITECTURAL REVIEW BOARD MUST BE PROVIDED FOR THE | | | LANDSCAPE AND IRRIGATION PROPOSED. | | | | | | 17. SATISFIED. PER EXHIBIT F, PLANT MATERIAL, A MINIMUM | | | OF 33 PERCENT OF ALL PLANT MATERIALS SHALL BE NATIVE TO | | | SOUTHERN FLORIDA. PROVIDE VERIFICATION. | | | | | | 18. SATISFIED. VERIFY CONDITION #7 AND #10 ARE | | | SATISFIED WITH THIS PLAN, AS IT APPEARS THE LAKE BANK | | | IS PROPOSED TO BE CHANGED, REMOVING SOME BUFFER ZONE | | | AND REQUIRED LITTORAL PLANTINGS. | | | | | | 19. SATISFIED. SHOW LOCATION OF PUMP EQUIPMENT AND | | | SOURCE FOR THE IRRIGATION SYSTEM TO MEET CONDITION #11 | | | REQUIRING USE OF SURFACE WATER FROM LAKES. | | | | | | | | | 20. SATISFIED. VERIFY CONDITION #12 IS MET FOR ALL | | | REQUIREMENTS FOR NATIVE VEGETATION INCLUDING AT LEAST | | | 50 PERCENT OF THE TREES BEING NATIVE SPECIES ADAPTED TO | | | SOIL CONDITIONS ON SITE. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO SCHEDULING FOR CITY COMMISSION, THE FLORIDA | | | FRIENDLY POINTS SHALL BE ADJUSTED IN THE DESIGN OPTIONS | | | CHART TO SHOW CREDIT FOR 25% DROUGHT TOLERANT TREES AND | | | SHRUBS BEYOND THE 51% NATIVE PLANT CREDIT, AND THE | | | GRASS OR GROUNDCOVER CREDIT REMOVED. | | | | | | 2. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
10-09-2018 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-09-2018 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-09-2018 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2018-10-09 10:03:13 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: CENTREPARK CPD RESIDENTIAL Z18070013 | | | OCTOBER 5, 2018 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. THERE ARE CORRECTIONS TO BE MADE TO THE | | | TREE DISPOSITION PLAN SHEET TD-1: | | | ? SATISFIED. SECTION 94-448 (D)(3) REQUIRES ALL NATIVE | | | TREES AND PALMS IN GOOD CONDITION TO BE PRESERVED OR | | | RELOCATED. THE 19 ROYAL PALMS CAN BE RELOCATED ON SITE, | | | WITHIN THE CENTREPARK CPD, OR THE CITY HAS MANY | | | LOCATIONS WITHIN PUBLIC RIGHT OF WAYS FOR RELOCATION. | | | ? SATISFIED. CORRECT THE PROVIDED MITIGATION CHART FOR | | | REPLACEMENT <20?SPREAD TOTAL TO 3,800 | | | ? SATISFIED. CORRECT THE REQUIRED MITIGATION TO 200 | | | TOTAL FOR LIGUSTRUMS | | | | | | 2. PARTIALLY SATISFIED. UPDATE THE FLORIDA FRIENDLY | | | LANDSCAPE DESIGN OPTIONS CHART TO CURRENT CODE SECTION | | | 94-446 (G) FOR ALL OPTIONS UNDER (3) GROUNDCOVER OR | | | GRASS. | | | THERE ARE CORRECTIONS NEEDED TO THE WORDING IN (3)(A) | | | AND (3)(B), (4)(A) AND (4)(B), (5)(A) AND (5)(B). | | | PLEASE REVISE. OPTIONS TAKEN NEED TO BE REVISED. | | | | | | 3. SATISFIED. PROVIDE THE PLANT LIST, LANDSCAPE | | | REQUIREMENTS, OVERALL LANDSCAPE REQUIREMENTS, AND | | | LANDSCAPE NOTES ON ONE SHEET ONLY. LANDSCAPE PLAN CAN | | | THEN BE CONSOLIDATED ONTO TWO SHEETS. | | | | | | 4. SATISFIED. REVISE THE PLANT LIST TO ADD A COLUMN FOR | | | FLORIDA NATIVE PLANTS AND FOR DROUGHT TOLERANCE LEVEL | | | FOR EACH SPECIES FOR CLARITY. | | | | | | 5. PARTIALLY SATISFIED. ON THE LANDSCAPE REQUIREMENTS | | | CHART, CORRECT THE SITE LANDSCAPE CALCULATIONS TO SHOW | | | THE SHADE TREE AND FLOWERING TREE CALCULATIONS AND ADD | | | THE ONE TREE PER UNIT REQUIRED PER SECTION 94-443 | | | (D)(2)A. TO ACHIEVE THE TOTAL REQUIRED TREE COUNT OF | | | 285. CORRECT THE PROVIDED TOTAL TREES TO 68, AS ANY | | | PALMS EXCEPT THE ROYALS COUNT AS 3 TO 1 FOR | | | SUBSTITUTION FOR REQUIRED TREES. STAFF SUGGESTS THAT | | | ONCE CORRECTIONS AND CALCULATIONS ARE FINALIZED, THE | | | DEFICIENCY OF TREES REQUESTED THROUGH THE WAIVER | | | PROCESS MAY BE ADDRESSED THROUGH IN LIEU MITIGATION AS | | | PROVIDED IN SECTION 94-448 (E)(2), OR POSSIBLE PLANTING | | | OF TREES WITHIN THE CENTREPARK CPD. | | | | | | REQUIRED ON SITE TREES ARE 39, MULTIFAMILY 242 EQUALS | | | 285. | | | | | | 6. SATISFIED. SHOW THE PERCENTAGE OF PALMS SUBSTITUTED | | | FOR REQUIRED TREES NOT EXCEEDING 35 PERCENT PER SECTION | | | 94-442(D) FOR THE TREES PROPOSED WITH THIS PLAN. | | | | | | 7. SATISFIED. CORRECT THE CALCULATIONS FOR THE NORTH | | | BUFFER TO 7. INCLUDE CALCULATIONS FOR THE SOUTH | | | REQUIRED BUFFER. | | | | | | | | | 8. SATISFIED. SHOW THE LOCATIONS OF ALL LANDSCAPE | | | BUFFERS ON THE LANDSCAPE AND SITE PLAN. THE SOUTH | | | PROPERTY LINE REQUIRES A 5 FOOT BUFFER. | | | | | | | | | 9. SATISFIED. SHOW COMPLIANCE WITH SECTION 94-445 L. | | | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT | | | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT | | | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE | | | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH | | | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH | | | FLORIDA LANDSCAPES. | | | | | | 10. SATISFIED. PLEASE SHOW LOCATIONS OF WATER, SEWER, | | | FIRE LINES, DRAINAGE LINES AND FPL TRANSFORMERS ON THE | | | LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH LANDSCAPING. | | | | | | 11. SATISFIED. PROVIDE SCREENING FOR ALL GROUND MOUNTED | | | VALVES AND EQUIPMENT. | | | | | | 12. NOT SATISFIED. SHOW THE LOCATIONS OF ALL SITE | | | LIGHTING ON THE LANDSCAPE PLAN AND RESOLVE ANY | | | CONFLICTS WITH TREES. | | | | | | THIS MAY BE PROPOSED AS A CONDITION OF APPROVAL. | | | ADDITIONAL COMMENTS 10/5/18: | | | | | | 13. TREE #45 MUST BE INCLUDED IN MITIGATION DUE IF IT | | | IS TO BE REMOVED. REVISE TREE DISPOSITION LIST TO SHOW | | | 300 MITIGATION REQUIRED AND REMOVE AS DISPOSITION. | | | | | | 14. JUSTIFICATION FOR WAIVER OF 143 TREES NEEDS TO BE | | | CLARIFIED TO PROVIDE THE COMPARATIVE VALUE FOR THE | | | NUMBER OF TREES PROVIDED AND PROPOSE A COMPARATIVE | | | VALUE FOR THE INCREASED TREE SIZES. | | | | | | 15. THE PLAZA AREA PLANTING PROPOSED DOES NOT PROVIDE | | | ANY TREE CANOPY OR SHADE IN THE PEDESTRIAN AREAS AND | | | DOES NOT PROVIDE ANY REASON FOR PEDESTRIAN ACCESS FROM | | | THE PUBLIC SIDEWALK. TREE CANOPY AND SHADE IS NOT | | | PROVIDED FOR THE SIDEWALK ALONG AUSTRALIAN AVENUE. THIS | | | DOES NOT ACCOMPLISH THE PEDESTRIAN FRIENDLY EXPERIENCE | | | THE CITY IS TRYING TO CREATE. | | | | | | RESOLUTION NO. 97-17 | | | | | | 16. SATISFIED. PER EXHIBIT F, APPROVAL FROM THE | | | ARCHITECTURAL REVIEW BOARD MUST BE PROVIDED FOR THE | | | LANDSCAPE AND IRRIGATION PROPOSED. | | | | | | 17. SATISFIED. PER EXHIBIT F, PLANT MATERIAL, A MINIMUM | | | OF 33 PERCENT OF ALL PLANT MATERIALS SHALL BE NATIVE TO | | | SOUTHERN FLORIDA. PROVIDE VERIFICATION. | | | | | | 18. SATISFIED. VERIFY CONDITION #7 AND #10 ARE | | | SATISFIED WITH THIS PLAN, AS IT APPEARS THE LAKE BANK | | | IS PROPOSED TO BE CHANGED, REMOVING SOME BUFFER ZONE | | | AND REQUIRED LITTORAL PLANTINGS. | | | | | | 19. SATISFIED. SHOW LOCATION OF PUMP EQUIPMENT AND | | | SOURCE FOR THE IRRIGATION SYSTEM TO MEET CONDITION #11 | | | REQUIRING USE OF SURFACE WATER FROM LAKES. | | | | | | | | | 20. SATISFIED. VERIFY CONDITION #12 IS MET FOR ALL | | | REQUIREMENTS FOR NATIVE VEGETATION INCLUDING AT LEAST | | | 50 PERCENT OF THE TREES BEING NATIVE SPECIES ADAPTED TO | | | SOIL CONDITIONS ON SITE. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
08-07-2018 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
08-07-2018 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
08-07-2018 |
Time |
17:26 |
Sent To |
|
|
| Notes |
| 2018-08-07 17:27:36 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: CENTREPARK CPD RESIDENTIAL Z18070013 | | | AUGUST 7, 2018 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. THERE ARE CORRECTIONS TO BE MADE TO THE TREE | | | DISPOSITION PLAN SHEET TD-1: | | | ? SECTION 94-448 (D)(3) REQUIRES ALL NATIVE TREES AND | | | PALMS IN GOOD CONDITION TO BE PRESERVED OR RELOCATED. | | | THE 19 ROYAL PALMS CAN BE RELOCATED ON SITE, WITHIN THE | | | CENTREPARK CPD, OR THE CITY HAS MANY LOCATIONS WITHIN | | | PUBLIC RIGHT OF WAYS FOR RELOCATION. | | | ? CORRECT THE PROVIDED MITIGATION CHART FOR REPLACEMENT | | | <20?SPREAD TOTAL TO 3,800 | | | ? CORRECT THE REQUIRED MITIGATION TO 200 TOTAL FOR | | | LIGUSTRUMS | | | | | | 2. UPDATE THE FLORIDA FRIENDLY LANDSCAPE DESIGN OPTIONS | | | CHART TO CURRENT CODE SECTION 94-446 (G) FOR ALL | | | OPTIONS UNDER (3) GROUNDCOVER OR GRASS. | | | | | | 3. PROVIDE THE PLANT LIST, LANDSCAPE REQUIREMENTS, | | | OVERALL LANDSCAPE REQUIREMENTS, AND LANDSCAPE NOTES ON | | | ONE SHEET ONLY. LANDSCAPE PLAN CAN THEN BE CONSOLIDATED | | | ONTO TWO SHEETS. | | | | | | 4. REVISE THE PLANT LIST TO ADD A COLUMN FOR FLORIDA | | | NATIVE PLANTS AND FOR DROUGHT TOLERANCE LEVEL FOR EACH | | | SPECIES FOR CLARITY. | | | | | | 5. ON THE LANDSCAPE REQUIREMENTS CHART, CORRECT THE | | | SITE LANDSCAPE CALCULATIONS TO SHOW THE SHADE TREE AND | | | FLOWERING TREE CALCULATIONS AND ADD THE ONE TREE PER | | | UNIT REQUIRED PER SECTION 94-443 (D)(2)A. TO ACHIEVE | | | THE TOTAL REQUIRED TREE COUNT OF 285. CORRECT THE | | | PROVIDED TOTAL TREES TO 68, AS ANY PALMS EXCEPT THE | | | ROYALS COUNT AS 3 TO 1 FOR SUBSTITUTION FOR REQUIRED | | | TREES. STAFF SUGGESTS THAT ONCE CORRECTIONS AND | | | CALCULATIONS ARE FINALIZED, THE DEFICIENCY OF TREES | | | REQUESTED THROUGH THE WAIVER PROCESS MAY BE ADDRESSED | | | THROUGH IN LIEU MITIGATION AS PROVIDED IN SECTION | | | 94-448 (E)(2), OR POSSIBLE PLANTING OF TREES WITHIN THE | | | CENTREPARK CPD. | | | | | | 6. SHOW THE PERCENTAGE OF PALMS SUBSTITUTED FOR | | | REQUIRED TREES NOT EXCEEDING 35 PERCENT PER SECTION | | | 94-442(D) FOR THE TREES PROPOSED WITH THIS PLAN. | | | | | | 7. CORRECT THE CALCULATIONS FOR THE NORTH BUFFER TO 7. | | | INCLUDE CALCULATIONS FOR THE SOUTH REQUIRED BUFFER. | | | | | | | | | 8. SHOW THE LOCATIONS OF ALL LANDSCAPE BUFFERS ON THE | | | LANDSCAPE AND SITE PLAN. THE SOUTH PROPERTY LINE | | | REQUIRES A 5 FOOT BUFFER. | | | | | | | | | 9. SHOW COMPLIANCE WITH SECTION 94-445 L. PLANT | | | SPECIES. A MINIMUM OF 60 PERCENT OF PLANT MATERIAL | | | ADDED SHALL BE FLORIDA NATIVE OR DROUGHT TOLERANT | | | SPECIES SELECTED FROM THE CITY LIST OR THE LIST OF | | | SPECIES IN THE MOST RECENT EDITION OF SOUTH FLORIDA | | | WATER MANAGEMENT DISTRICT WATERWISE SOUTH FLORIDA | | | LANDSCAPES. | | | | | | 10. PLEASE SHOW LOCATIONS OF WATER, SEWER, FIRE LINES, | | | DRAINAGE LINES AND FPL TRANSFORMERS ON THE LANDSCAPE | | | PLAN AND RESOLVE CONFLICTS WITH LANDSCAPING. | | | | | | 11. PROVIDE SCREENING FOR ALL GROUND MOUNTED VALVES AND | | | EQUIPMENT. | | | | | | 12. SHOW THE LOCATIONS OF ALL SITE LIGHTING ON THE | | | LANDSCAPE PLAN AND RESOLVE ANY CONFLICTS WITH TREES. | | | | | | 13. | | | | | | RESOLUTION NO. 97-17 | | | | | | 14. PER EXHIBIT F, APPROVAL FROM THE ARCHITECTURAL | | | REVIEW BOARD MUST BE PROVIDED FOR THE LANDSCAPE AND | | | IRRIGATION PROPOSED. | | | | | | 15. PER EXHIBIT F, PLANT MATERIAL, A MINIMUM OF 33 | | | PERCENT OF ALL PLANT MATERIALS SHALL BE NATIVE TO | | | SOUTHERN FLORIDA. PROVIDE VERIFICATION. | | | | | | 16. VERIFY CONDITION #7 AND #10 ARE SATISFIED WITH THIS | | | PLAN, AS IT APPEARS THE LAKE BANK IS PROPOSED TO BE | | | CHANGED, REMOVING SOME BUFFER ZONE AND REQUIRED | | | LITTORAL PLANTINGS. | | | | | | 17. SHOW LOCATION OF PUMP EQUIPMENT AND SOURCE FOR THE | | | IRRIGATION SYSTEM TO MEET CONDITION #11 REQUIRING USE | | | OF SURFACE WATER FROM LAKES. | | | | | | | | | 18. VERIFY CONDITION #12 IS MET FOR ALL REQUIREMENTS | | | FOR NATIVE VEGETATION INCLUDING AT LEAST 50 PERCENT OF | | | THE TREES BEING NATIVE SPECIES ADAPTED TO SOIL | | | CONDITIONS ON SITE. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
3 |
Status |
P |
Date |
11-26-2018 |
|
|
Cont ID |
|
| Sent By |
|
Date |
11-26-2018 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
11-26-2018 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
F |
Date |
09-28-2018 |
|
|
Cont ID |
|
| Sent By |
|
Date |
09-28-2018 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
09-28-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-09-28 08:35:27 | BASED ON A REREVIEW OF THE PLAN THERE ARE DUMPSTERS IN | | | THE INTERIOR. IF THEY ARE NOT USING A ROLL OFF | | | COMPACTOR AND PLAN ON ROLLING THE DUMPSTERS OUT FOR | | | PICKUP THEY WILL NEED TO CONTACT OUR OFFICE TO ARRANGE | | | THE SERVICE. BASED ON THE AUTO TURN WE CAN MANAGE THE | | | SERVICE BUT I NEED TO KNOW DEFINITIVELY IF THEY ARE | | | USING A ROLL OFF COMPACTOR OR WILL THEY BE USING OUR | | | FRONT LOAD SERVICE. | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
P |
Date |
08-07-2018 |
|
|
Cont ID |
|
| Sent By |
|
Date |
08-07-2018 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
08-07-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-08-07 15:55:02 | BASED ON THE PRINT THE SERVICES TO BE A ROLLOFF | | | COMPACTOR. THE UNIT MUST BE SERVICED BY ONE OF THE | | | CITY'S FRANCHISE HOLDERS. |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
08-07-2018 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
08-07-2018 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
08-07-2018 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2018-08-07 11:40:01 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP:// | | | WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER | | | MITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. TWO FEET OF FREEBOARD ABOVE BASE FLOOD ELEVATION IS | | | REQUIRED FOR STRUCTURES IN SPECIAL FLOOD HAZARD AREAS. | | | THE SURVEY INDICATES THE BASE FLOOD ELEVATION IS 12.7 | | | FEET NAVD 1988 (= 14.22 FEET NGVD 1929). MINIMUM | | | FINISHED FLOOR WILL BE 16.22 FEET NGVD 1929. | | | | | | 2. LABEL EASEMENTS ON ALL THE LANDSCAPE PLANS. | | | | | | 3. SHOW UTILITIES ON THE LANDSCAPE PLANS. | | | | | | 4. APPROVAL FROM THE PUBLIC UTILITIES DEPARTMENT IS | | | REQUIRED FOR THE TREES PROPOSED WITHIN THE UTILITY | | | EASEMENTS. | | | | | | 5. SHOW THE LAKE MAINTENANCE AREA FOR THE EXPANDED LAKE | | | AREA. | | | | | | 6. PROVIDE A CROSS SECTION OF THE PROPOSED LAKE SECTION | | | SHOWING SLOPES AND MAXIMUM DEPTH. | | | | | | 7. INDICATE MILL AND OVERLAY LIMITS FOR TRENCH CUTS | | | WITHIN THE PUBLIC RIGHT OF WAY. | | | | | | 8. THE PAVILION APPEARS TO BE WITHIN THE PROPOSED | | | DRAINAGE EASEMENT. CAN THE EXISTING OUTFALL PIPE BE | | | MOVED TO THE CENTER OF THE EXISTING DRAINAGE EASEMENT? | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION MAY | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. PROVIDE A COPY OF THE MODIFIED SFWMD ERP APPROVAL | | | PRIOR TO STARTING CONSTRUCTION. | | | - IT APPEARS THIS PROPERTY IS IN BASIN 2 OF THE MASTER | | | SYSTEM AND THE CONCEPTUAL ENGINEERING PLAN SHOWS PART | | | OF THE SITE WILL DISCHARGE TO THE LAKE IN BASIN 1. | | | - EXHIBIT 6 OF THE STAFF REPORT FOR ERP PERMIT | | | MODIFICATION FOR APPLICATION NO. 000323-13 INDICATES | | | 356 LINEAR FEET OF 4. X 8 EXFILTRATION TRENCH IS NEEDED | | | IN BASIN 2 TO MEET THE C-51 BASIN RULE. IS THIS TRENCH | | | STILL NECESSARY AND WILL THE LENGTH NEED TO BE ADJUSTED | | | BASED ON THE CURRENT DESIGN CONFIGURATION ON THIS | | | PARCEL. | | | | | | 3. EROSION CONTROL PLAN AND DETAILS TO BE SUBMITTED | | | WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
P |
Date |
10-18-2018 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
10-18-2018 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
10-18-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-10-18 11:31:28 | PASSED WITH CONDITIONS: | | | | | | 1. REPLAT PRIOR TO C.O. | | | 2. RELOCATION OF DRAINAGE WILL NEED TO BE ACCOMPLISHED | | | PRIOR TO BUILDING PERMIT ALONG WITH EASEMENT | | | ABANDONMENT. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
08-06-2018 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
08-06-2018 |
Time |
08:55 |
Rev Time |
|
| Received By |
vnoel |
Date |
08-06-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-08-06 09:16:00 | 1. EXISTING DRAINAGE EASEMENT WILL NEED TO BE ABANDONED | | | AND NEW EASEMENT GRANTED. | | | 2. POOL DECK/PAVILION CANNOT ENCROACH INTO PROPOSED DE. | | | 3. IF PARALLEL PARKING APPROVED, A SIDEWALK EASEMENT | | | WILL BE REQUIRED. | | | 4. PARCEL WILL NEED TO BE REPLATTED AND INCLUDE | | | DEDICATION OF EXPANDED LAKE. UNITY OF TITLE WILL NEED | | | TO BE RELEASED. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
12-10-2018 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2018-12-10 11:50:25 | Z18070013 CENTERPARK R3 | | | PASSED WITH THE FOLLOWING CONDITIONS OF APPROVAL: | | | 1. APPLICANT WILL PROVIDE HIGH QUALITY BICYCLE | | | FACILITIES FOR THE ENTIRE LENGTH OF CENTRE PARK ON BOTH | | | SIDES OF CENTRE PARK. | | | 2. PARKING WILL BE UNBUNDLED FROM RESIDENTS' LEASES. | | | 3. APPLICANT WILL PROVIDE FOR A PERIOD OF ONE YEAR A | | | SUBSIDIZED TRI-RAIL PASS WHICH REDUCES THE FARES BY 50% | | | FOR NEW RESIDENTS. | | | 4. APPLICANT WILL CONTINUE TO COORDINATE WITH TRI-RAIL | | | TO INVESTIGATE HAVING THE TRI-RAIL AIRPORT SHUTTLE ADD | | | A STOP AT THE EXISTING AND PROPOSED PALM TRAN STOPS | | | NEAR THE SITE. | | | 5. APPLICANT WILL CONTINUE TO COORDINATE WITH PALM TRAN | | | TO UPGRADE THE NEARBY PALM TRAN BUS SHELTERS ON | | | AUSTRALIAN AVENUE NEAR CENTRE PARK BOULEVARD. | | | | | | ERIK D. FERGUSON, P.E. | | | CITY TRANSPORTATION ENGINEER |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
10-04-2018 |
|
|
Cont ID |
|
| Sent By |
|
Date |
10-04-2018 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
10-04-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-10-04 16:43:41 | Z18070013 1500 CENTREPARK (SEPTEMBER 20, 2018 | | | SUBMITTAL) | | | 1. PROVIDE VEHICULAR LEVEL OF SERVICE ANALYSIS FOR | | | CENTREPARK DRIVEWAY. DETERMINE IF A LEFT AND RIGHT EXIT | | | LANE ARE REQUIRED INSTEAD OF THE CURRENTLY PROPOSED | | | SHARED LEFT AND RIGHT EXIT LANE. | | | 2. THE SIGHT TRIANGLES FOR CENTERPARK DRIVE NORTH | | | DRIVEWAY WERE NOT PREPARED ACCORDING TO FDOT DESIGN | | | STANDARDS OR FLORIDA GREENBOOK. PLEASE REVISE. | | | 3. THE PEDESTRIAN REFUGEE ISLANDS ON THE UNMARKED | | | CROSSWALKS ACROSS CENTREPARK BOULEVARD AT CENTREPARK | | | DRIVE NORTH NEEDS TO BE ACCESSIBLE. PLEASE REVISE. | | | ALSO, PROVIDE RAISED CURB IMMEDIATELY ADJACENT TO THE | | | REFUGE ISLAND TO PROTECT PEDESTRIANS FROM LEFT-TURNING | | | VEHICLES. | | | 4. AS A PARTIAL MITIGATION TO THE REQUESTED WAIVER OF | | | 144 SHADE TREES (59% BELOW CODE REQUIREMENTS) AND TO | | | ALSO IMPROVE WALKABILITY, MODIFY THE DESIGN TO PROVIDE | | | SHADE TREES ALONG AUSTRALIAN AVENUE. ALONG THE | | | APPLICANT?S AUSTRALIAN FRONTAGE A LANDSCAPE BUFFER | | | COULD BE PROVIDED BETWEEN THE TRAVEL LANE AND THE | | | SIDEWALK. THE SIDEWALK COULD BE RELOCATED INTO THE | | | UTILITY EASEMENT. PROVIDE A SIDEWALK EASEMENT IF THE | | | SIDEWALK ENCROACHES THE PROPERTY LINE. TO THE NORTH OF | | | THE APPLICANT?S AUSTRALIAN FRONTAGE A LANDSCAPE BUFFER | | | AND SHADE TREES COULD ALSO BE PROVIDED BETWEEN THE | | | TRAVEL LANE AND SIDEWALK WITH APPROVAL OF THE | | | CENTREPARK POA. TO THE SOUTH OF THE APPLICANT?S | | | PROPERTY THERE MAY BE AN OPPORTUNITY TO PLANT SHADE | | | TREES BETWEEN THE SIDEWALK AND THE LAKE. COORDINATE | | | WITH THE COUNTY FOR IMPROVEMENTS ALONG AUSTRALIAN | | | AVENUE. | | | 5. REVIEW GRADE PROPOSED GRADE CHANGE AT BACK ALONG | | | CENTREPARK TO ENSURE THAT SLOPES AREN'T TOO STEEP FOR | | | LANDSCAPING. | | | 6. THE PROPOSED DEVELOPMENT HAS REQUESTED A PARKING | | | REDUCTION OF 64 SPACES (13% BELOW CODE REQUIREMENTS), | | | HOWEVER, NO MITIGATION MEASURES ARE PROPOSED BY THE | | | APPLICANT TO REDUCE PARKING DEMAND. PLEASE INCLUDE THE | | | FOLLOWING AS MITIGATION STRATEGIES: | | | A. THE JUSTIFICATION STATEMENT INDICATES THAT A PORTION | | | OF THE BICYCLE RACKS ARE AVAILABLE TO THE PUBLIC, BUT | | | THERE ARE CURRENTLY NO BICYCLE FACILITIES CONNECTING TO | | | THE SITE. PLEASE PROVIDE STRIPED BUFFERED BICYCLE LANES | | | ON BOTH SIDES OF CENTREPARK BOULEVARD BETWEEN | | | AUSTRALIAN BOULEVARD AND MERCER AVENUE, WHICH IS A KEY | | | BICYCLE ROUTE LEADING TO DOWNTOWN WEST PALM BEACH. THE | | | BICYCLE LANES SHOULD BE PROVIDED BY ELIMINATING ONE | | | TRAVEL LANE IN EACH DIRECTION ON CENTREPARK BOULEVARD. | | | GREEN COLORED PAVEMENT SHOULD BE PROVIDED ACROSS | | | CONFLICT AREAS PER GUIDANCE IN FDOT DESIGN MANUAL. THE | | | BIKE LANES SHOULD BE STRIPED WITH THERMOPLASTIC | | | PAVEMENT MARKINGS. A K-71 FLEXIBLE BOLLARD SHOULD BE | | | PROVIDED PERIODICALLY IN THE BUFFER. | | | B. AS PARTIAL TREE MITIGATION AND TO PROVIDE A MODE | | | SHIFT TO CYCLING, INSTEAD OF A PAINTED BIKE BUFFER, THE | | | BIKE BUFFER COULD CONSIST OF A RAISED MEDIAN WITH TREES | | | AND GROUND COVER. | | | C. THE JUSTIFICATION STATEMENT INDICATES THAT THE | | | PROPOSED PROJECT WILL IMPROVE THE WALKABILITY AND | | | LIVABILITY IN THIS AREA OF THE CITY, AND THAT THE SITE | | | WILL PROVIDE EASY ACCESS TO PUBLIC TRANSPORTATION AND | | | OTHER NON-MOTORIZED TRANSPORTATION AMENITIES. HOWEVER, | | | NO IMPROVEMENTS ARE PROPOSED ON THE SIDEWALKS ON | | | CENTREPARK BOULEVARD AND AUSTRALIAN AVENUE SURROUNDING | | | THE SITE, AND THE SIDEWALKS REMAIN AT A MINIMUM OF 5 TO | | | 6-FOOT WIDE WITH NO SHADE TREE COVERAGE. PLEASE PROVIDE | | | WIDER SIDEWALKS AND SHADE TREES ALONG THESE TWO | | | ROADWAYS PER COMMENT #3 WHICH WILL PROVIDE A MUCH MORE | | | ATTRACTIVE ENVIRONMENT FOR PEDESTRIANS AND THEREFORE | | | IMPROVING WALKABILITY. PLEASE ALSO INDICATE WHAT ?OTHER | | | NON-MOTORIZED TRANSPORTATION AMENITIES? INCLUDES. | | | D. PLEASE IMPLEMENT TRANSPORTATION DEMAND MANAGEMENT | | | STRATEGIES INCLUDING UNBUNDLING PARKING SPACES FROM THE | | | LEASE, PROVIDING BIKE SHARE STATIONS ON SITE, AND | | | PROVIDING SUBSIDIZED PALM TRAN OR TRI RAIL PASSES WITH | | | AT LEAST 50% DISCOUNT FOR NEW RESIDENTS FOR THE FIRST | | | YEAR. | | | 7. THE FOLLOWING COMMENTS ARE RELATED TO THE REDUCED | | | PARKING STATEMENT: | | | A. PROVIDE SUPPORTING INFORMATION FOR THE ANTICIPATION | | | THAT THE MAJORITY OF THE RESIDENTS WILL HAVE ONLY ONE | | | VEHICLE. | | | B. SUMMARIZE THE BUS ROUTE INFORMATION INCLUDING | | | DESTINATIONS AND FREQUENCIES FOR THE BUS ROUTES NEAR | | | THE SITE, UNDER PALM TRAN?S LATEST ROUTE PERFORMANCE | | | MAXIMIZATION PROGRAM. THE FREQUENCY OF BUSES NEAR THE | | | SITE APPEARS TO RANGE FROM 30 MINUTES TO 60 MINUTES | | | HEADWAY, WHICH DO NOT APPEAR TO PROVIDE VERY ATTRACTIVE | | | TRANSIT QUALITY OF SERVICE. | | | C. THE CLOSEST TRI-RAIL STATION IS APPROXIMATELY 2 | | | MILES AWAY, WHICH IS NOT CLOSE BY FROM A PEDESTRIAN | | | PERSPECTIVE. | | | D. PROVIDE SUPPORTING INFORMATION FOR THE ANTICIPATION | | | THAT A SUBSTANTIAL AMOUNT OF RESIDENTS WILL UTILIZE THE | | | MASS TRANSIT SYSTEM. | | | E. PROVIDE SUPPORTING INFORMATION FOR THE ANTICIPATION | | | THAT THERE WILL BE A SUBSTANTIAL AMOUNT OF PEDESTRIAN | | | ACTIVITY IN LIEU OF VEHICULAR USE. | | | F. PROVIDE SUPPORTING INFORMATION ON SIMILAR SUCCESSFUL | | | DEVELOPMENTS WITH PROVIDED PARKING OF 1 SPACE PER | | | 1-BEDROOM UNIT AND 1.5 SPACES PER 2-BEDROOM UNIT. | | | DETAILS SUCH AS THE PROXIMITY TO QUALITY TRANSIT, | | | ADJACENT LAND USES, BICYCLE FACILITIES, PEDESTRIAN | | | FACILITIES, SOCIO ECONOMIC DATA, STREET INTERSECTION | | | DENSITY, AND ACTUAL PARKING UTILIZATION ARE KEY | | | INFORMATION TO IDENTIFY COMPARABLE DEVELOPMENTS WITH | | | ADEQUATE PARKING LOCATED IN SIMILAR ENVIRONMENTS. | | | G. CLARIFY IF THE SITES USED IN THE ITE PARKING | | | GENERATION MANUAL ARE LOCATED IN SIMILAR ENVIRONMENTS. | | | PREVIOUS COMMENTS WHICH ARE YET TO BE ADDRESSED ARE | | | INCLUDED BELOW: | | | 8. CLARIFY IF THE INTERNALIZATION ASSUMPTION FOR THE | | | VESTED DEVELOPMENT IS CONSISTENT WITH THE TRIP | | | GENERATION FROM THE DRI. | | | 9. COORDINATE WITH PALMTRAN TO PROVIDE A NEW NORTHBOUND | | | BUS STOP WITH BUS SHELTER ON AUSTRALIAN AVENUE NEAR | | | CENTREPARK BOULEVARD. ALSO, COORDINATE WITH PALMTRAN TO | | | PROVIDE BUS SHELTER FOR THE EXISTING SOUTHBOUND BUS | | | STOP NEAR CENTREPARK BOULEVARD IF SUFFICIENT | | | RIGHT-OF-WAY OR EASEMENT IS AVAILABLE. | | | 10. COORDINATE WITH TRI-RAIL TO HAVE A TRI-RAIL SHUTTLE | | | STOP AT THE EXISTING AND PROPOSED PALMTRAN STOPS NEAR | | | THE SITE. | | | | | | ERIK D. FERGUSON, PE | | | CITY TRANSPORTATION ENGINEER | | | 561-494-1092 | | | [email protected] | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
08-06-2018 |
|
|
Cont ID |
|
| Sent By |
|
Date |
08-06-2018 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
08-06-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-08-06 17:35:38 | Z18070013 1500 CENTREPARK (JULY 10, 2018 SUBMITTAL) | | | - CLARIFY IF THE INTERNALIZATION ASSUMPTION FOR THE | | | VESTED DEVELOPMENT IS CONSISTENT WITH THE TRIP | | | GENERATION FROM THE DRI. | | | - THE SOUTHERN DRIVEWAY APPEARS TO BE FOR GARBAGE | | | PICK-UP ONLY, AND THE ASSUMPTION OF 10% OF TRIPS USING | | | THIS DRIVEWAY MIGHT BE TOO HIGH. PLEASE CLARIFY OR | | | REVISE. | | | - INCLUDE TRIP DISTRIBUTION AND ASSIGNMENT FROM SITE | | | ACCESS TO AUSTRALIAN AVENUE AND MERCER AVENUE. | | | - PROVIDE WEEKDAY DAILY VOLUMES ALONG CENTREPARK | | | BOULEVARD. | | | - PROVIDE HCM 2010 OR 6TH EDITION INTERSECTION ANALYSIS | | | AT AUSTRALIAN AVENUE/CENTREPARK BOULEVARD WITH SITE | | | TRAFFIC. | | | - INCLUDE EVALUATION OF THE DRI DEVELOPMENT ORDER | | | CONDITIONS IN THE SUBMITTAL. | | | - ALIGN THE GARAGE DRIVEWAY WITH CENTREPARK DRIVE | | | NORTH. | | | - PROVIDE SIGHT TRIANGLE EXHIBIT FOR CENTERPARK DRIVE | | | NORTH DRIVEWAY. VERIFY THE DRIVEWAY MEETS SIGHT | | | DISTANCE REQUIREMENTS AS SHOWN IN FDOT DESIGN STANDARDS | | | OR FLORIDA GREENBOOK. | | | - CLARIFY IF THE ENTRANCE TO THE GARAGE IS GATED. THE | | | RENDERING SHOWS THAT THE ENTRANCE IS GATED. IF SO, | | | PROVIDE A QUEUING ANALYSIS AT THE ENTRANCE GATE. | | | - SHOW INTERNAL AND EXTERNAL PEDESTRIAN CIRCULATION AND | | | ACCESS. | | | - PROVIDE PEDESTRIAN PATHWAY TO CONNECT TO THE ADJACENT | | | PROPERTY AT THE SOUTHEAST CORNER THROUGH THE | | | CROSS-ACCESS AGREEMENT. | | | - PROVIDE PEDESTRIAN REFUGEE ISLANDS ON THE UNMARKED | | | CROSSWALKS ACROSS CENTREPARK BOULEVARD AT CENTREPARK | | | DRIVE NORTH. | | | - AS A PARTIAL MITIGATION TO THE REQUESTED WAIVER OF | | | 221 SHADE TREES (90% BELOW CODE REQUIREMENTS), CONSIDER | | | PROVIDING 6-FOOT MINIMUM SIDEWALK (8-FOOT PREFERRED) | | | WITH AT LEAST 4-FOOT LANDSCAPE BUFFER ALONG CENTREPARK | | | BOULEVARD AND AUSTRALIAN AVENUE, AND PLANT SHADE TREES | | | ON THE LANDSCAPE BUFFER. PROVIDE SIDEWALK AGREEMENT IF | | | THE SIDEWALK ENCROACHES THE PROPERTY LINE. | | | - SHOW RIGHT OF WAY WIDTH FROM CENTERLINE AND FULL | | | CENTERLINE. | | | - COORDINATE WITH PALMTRAN TO PROVIDE A NEW NORTHBOUND | | | BUS STOP WITH BUS SHELTER ON AUSTRALIAN AVENUE NEAR | | | CENTREPARK BOULEVARD. ALSO, COORDINATE WITH PALMTRAN TO | | | PROVIDE BUS SHELTER FOR THE EXISTING SOUTHBOUND BUS | | | STOP NEAR CENTREPARK BOULEVARD IF SUFFICIENT | | | RIGHT-OF-WAY OR EASEMENT IS AVAILABLE. | | | - COORDINATE WITH TRI-RAIL TO HAVE A TRI-RAIL SHUTTLE | | | STOP AT THE EXISTING AND PROPOSED PALMTRAN STOPS NEAR | | | THE SITE. | | | - THE PROPOSED COMPREHENSIVE PLAN TEXT AMENDMENT | | | INCLUDES A NUMBER OF STRATEGIES TO MITIGATE THE PARKING | | | DEMAND. CLARIFY WHAT MITIGATION MEASURES ARE PROPOSED | | | BY THE APPLICANT TO MITIGATE THE PARKING NEEDS. | | | - CENTREPARK BOULEVARD IS PLANNED FOR SEPARATED BIKE | | | LANES, AND IS A KEY BICYCLE ROUTE TO GET TO DOWNTOWN | | | PER THE BICYCLE MASTER PLAN. CONTRIBUTE FUNDING TOWARDS | | | THE SEPARATED BIKE LANES. | | | - CHECK ROADWAY SIGHT DISTANCE WITH PROPOSED ON-STREET | | | PARKING. THERE MAY NOT BE ENOUGH SIGHT DISTANCE TO | | | ALLOW FOR PARALLEL PARKING MANEUVERS TO OCCUR SAFELY. | | | - WE WILL PROVIDE A DECISION ON IF PARALLEL PARKING | | | WILL BE ALLOWED ON CENTREPARK. | | | - PROPOSED PARALLEL PARKING SPACES IN FRONT OF THE | | | PROPERTY ARE IN CONFLICT WITH THE PLANNED PROTECTED | | | BIKE LANES. | | | - PROVIDE AVAILABILITY LETTER FOR WATER, SEWER, | | | GARBAGE, SANITATION AND STORM. | | | - PROVIDE AUTOTURN TEMPLATE FOR GARBAGE PICKUPS. | | | - THE PROPOSED CODE LANGUAGE SHOULD BE REVISED TO AVOID | | | MISINTERPRETATION THAT THE LIMIT ?BETWEEN OKEECHOBEE | | | BOULEVARD AND BELVEDERE ROAD? ALSO APPLIES TO I-95, | | | E.G. REVISE TO ?EAST OF AUSTRALIAN AVENUE BETWEEN | | | OKEECHOBEE BOULEVARD AND BELVEDERE ROAD OR EAST OF | | | I-95?. | | | - MODIFY THE PROPOSED CODE LANGUAGE ITEM ?J? TO SAY THE | | | FOLLOWING OR EQUIVALENT: ?THE APPLICANT SHALL | | | DEMONSTRATE THAT THE PROPERTY HAS AN ACCESSIBLE | | | PEDESTRIAN ROUTE OF AT MOST ? MILE FROM THE SITE ACCESS | | | POINT TO A TRANSIT STOP FOR ANY HIGH FREQUENCY (HEADWAY | | | OF 15 MINUTES OR LESS) OR PREMIUM TRANSIT SERVICE.? | | | - THE PROPOSED ITEMS ?F TO J? SHOULD BE IN ADDITIONAL | | | TO WHAT ARE CURRENTLY REQUIRED UNDER SECTION | | | 94-207(B)(13), I.E. THE APPLICANT SHALL MEET A MINIMUM | | | OF THREE OR MORE OF ITEMS (13) ?A TO E?, AND IMPLEMENT | | | SEVERAL MITIGATION MEASURES AMONG ITEMS ?F TO J? OR AS | | | REQUIRED BY THE CITY. | | | - ADD ADDITIONAL STRATEGIES TO THE PROPOSED TEXT | | | AMENDMENT INCLUDING UNBUNDLED PARKING, PARKING CASH-OUT | | | PROGRAM, REMOTE PARKING/SHUTTLE SERVICE. REFER TO THE | | | CITY?S PARKING AND TDM STUDY FOR DETAILS ON THESE | | | MEASURES. | | | - A POTENTIAL SOLUTION TO PROVIDE BIKE LANES AND | | | PARALLEL PARKING ON CENTREPARK BOULEVARD IS TO CONVERT | | | ONE OF THE LANES TO A SERVICE ROAD THAT BICYCLES AND | | | PARKING MANEUVERS SHARE. PHOTOS OF THE SERVICE ROAD | | | CONCEPT WILL BE PROVIDED AT PPRC MEETING. | | | | | | ERIK D. FERGUSON, PE | | | CITY TRANSPORTATION ENGINEER | | | [email protected] | | | 561-494-1092 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
10-31-2018 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
10-31-2018 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
10-31-2018 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2018-10-31 10:09:40 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 10.31.2018 | | | PROJECT NO.: Z18070013 | | | CASE NO.: PB 791GG | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. ALL OUTSTANDING UTILITY LETTERS SHALL BE PROVIDED. - | | | STILL AWAITING FPL LETTER. | | | | | | 2. TRAFFIC CONCURRENCY APPROVAL SHALL BE PROVIDED FROM | | | PALM BEACH COUNTY. - THE ONLY LETTER THAT HAS BEEN | | | RECEIVED IS DATED 09/10/2018, WHICH INDICATES THAT THE | | | PROJECT DOES NOT MEET THE TRAFFIC PERFORMANCE STANDARDS | | | OF PALM BEACH COUNTY. | | | | | | 4. APPROVAL FROM THE CENTREPARK ARCHITECTURAL REVIEW | | | COMMITTEE SHALL BE PROVIDED. - LETTER OF CONSENT WAS | | | RECEIVED, BUT WHAT IS BEING DONE ABOUT THE COMMENTS OR | | | AREAS OF CONCERN THAT WERE NEEDING FURTHER | | | DISCUSSION/REVIEW? | | | | | | 8. PLEASE NOTE THAT PURSUANT TO SECTION 5, CONDITION | | | #11 OF RESOLUTION NO. 97-17, ALL IRRIGATION SHALL BE | | | PROVIDED UTILIZING THE LAKES (NO POTABLE WATER SHALL BE | | | UTILIZED). PLEASE PROVIDE A NOTE ON THE PLANS | | | INDICATING COMPLIANCE WITH SUCH PROVISION. - RESPONSE | | | INDICATES THAT THIS NOTE WAS ADDED ON THE LANDSCAPE | | | PLANS...PLEASE PROVIDE A SHEET # AS I WAS UNABLE TO | | | FIND IT. | | | | | | 11. PLEASE PROVIDE A TURNING RADIUS ANALYSIS FOR THE | | | UTILIZATION OF THE LOADING AREA AND DUMPSTER/COMPACTOR. | | | - THE TURNING RADIUS ANALYSIS INDICATES THAT THE | | | MANEUVERING OF THE VEHICLES REQUIRES ENCROACHMENT ONTO | | | THE ADJACENT PROPERTY, OUTSIDE OF THE EXISTING ACCESS | | | EASEMENT. AN ADDITIONAL EASEMENT WILL BE REQUIRED, OR | | | THE CIRCULATION MODIFIED SO AS NOT TO EXTEND OUTSIDE OF | | | THE EXISTING EASEMENT. IF AN ADDITIONAL EASEMENT IS | | | PROPOSED, PLEASE PROVIDE WRITTEN AGREEMENT FROM THE | | | ADJACENT PROPERTY OWNER. | | | | | | 15. THE DESIGN OF THE GROUNDFLOOR UNITS SHOULD BE | | | MODIFIED SUCH THAT THEY HAVE A WALK-UP ENTRANCE WITH | | | FRONT DOOR FACING THE STREET, ETC. THE CURRENT DESIGN | | | IS SUCH THAT IT APPEARS TO BE ONLY A SIDEWALK LEADING | | | TO A BACK PATIO/SLIDING DOOR. - IS THERE ANY WAY TO | | | HAVE THE DOORS FACING THE STREET? | | | | | | 17. AS THE BUILDING IS LOCATED AT THE PROPERTY LINE AND | | | THERE APPEAR TO BE BALCONIES AND ROOF OVERHANGS | | | ENCROACHING INTO THE REQUIRED SETBACK, PLEASE ENSURE | | | THAT ALL PLANS CLEARLY IDENTIFY THE ENCROACHMENTS AND | | | ARE DIMENSIONED ACCORDINGLY. THE ELEVATIONS APPEAR TO | | | SHOW OVERHANGS ON THE UPPER FLOOR THAT ARE NOT SHOWN ON | | | THE ROOF PLAN AND/OR FLOOR PLANS. ENSURE THAT OVERHANGS | | | DO NOT PROJECT MORE THAN 3 FEET INTO THE REQUIRED | | | SETBACK. - - SOME OF THE FRONT STOOPS ARE ENCROACHING | | | INTO THE SETBACK, WHICH IS PERMITTED SO LONG AS THEY DO | | | NOT EXCEED THREE (3) FEET IN HEIGHT; PLEASE PROVIDE | | | DETAILS INDICATING COMPLIANCE WITH SUCH. | | | | | | 24. (NEW COMMENT) - THE SITE DESIGN SHOWN ON SHEET A2.1 | | | DIFFERS FROM THAT WHICH IS SHOWN ON THE PROPOSED SITE | | | PLAN. SHEET A2.1 STILL INDICATES THE ON-STREET PARKING, | | | ETC. PLEASE ENSURE THAT ALL PLANS ARE CONSISTENT. | | | ___________________________________________ | | | | | | NOTE, STAFF IS CONTINUING TO DISCUSS THE PROPOSED TEXT | | | AMENDMENT PERTAINING TO THE PARKING REQUIREMENTS AND | | | WILL FOLLOW UP SOON IN THAT REGARD TO DISCUSS THE | | | SPECIFIC LANGUAGE, AS WELL AS ANY POTENTIAL IMPACTS TO | | | THE PROJECT (IF ANY). | | | ___________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
08-08-2018 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
08-08-2018 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
08-08-2018 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2018-08-08 11:09:05 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 08.08.2018 | | | PROJECT NO.: Z18070013 | | | CASE NO.: PB 791GG | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. ALL OUTSTANDING UTILITY LETTERS SHALL BE PROVIDED. | | | | | | 2. TRAFFIC CONCURRENCY APPROVAL SHALL BE PROVIDED FROM | | | PALM BEACH COUNTY. | | | | | | 3. SCHOOL CAPACITY AVAILABILITY DETERMINATION (SCAD) | | | SHALL BE SUBMITTED TO THE SCHOOL DISTRICT OF PALM BEACH | | | COUNTY. | | | | | | 4. APPROVAL FROM THE CENTREPARK ARCHITECTURAL REVIEW | | | COMMITTEE SHALL BE PROVIDED. | | | | | | 5. UPDATED WARRANTY DEED SHALL BE PROVIDED. | | | | | | 6. PLEASE NOTE THAT THE PROJECT WILL BE SUBJECT TO THE | | | CENTREPARK AFFORDABLE AND WORKFORCE HOUSING POLICY THAT | | | WAS APPROVED WITH THE ADOPTION OF RESOLUTION NO. 98-17. | | | AS REQUIRED BY THE POLICY, THE APPLICATION SHALL | | | PROVIDE A WRITTEN CERTIFICATION AS PART OF THE SITE | | | PLAN APPLICATION IDENTIFYING WHICH UNITS WILL BE | | | OFFERED AS WORKFORCE HOUSING UNITS. PLEASE REFER TO THE | | | POLICY FOR ALL UNIT RESTRICTIONS THAT ARE REQUIRED. | | | | | | 7. PLEASE NOTE THAT PURSUANT TO RESOLUTION NO. 98-17, | | | UPON OBTAINING SITE PLAN APPROVAL, THE APPLICANT SHALL | | | CONTRIBUTE $150/UNIT TO THE WORKFORCE HOUSING TRUST | | | FUND, UNLESS THE CITY CHOOSES TO USE IT TOWARD THE | | | DEVELOPMENT OF A TRANSIT PLAN TO PROVIDE CONNECTIVITY | | | BETWEEN DOWNTOWN AND CENTREPARK. IF THIS OPTION IS | | | CHOSEN, THEN THE APPLICANT SHALL WORK WITH THE CITY ON | | | THE DEVELOPMENT OF THIS PLAN. | | | | | | 8. PLEASE NOTE THAT PURSUANT TO SECTION 5, CONDITION | | | #11 OF RESOLUTION NO. 97-17, ALL IRRIGATION SHALL BE | | | PROVIDED UTILIZING THE LAKES (NO POTABLE WATER SHALL BE | | | UTILIZED). PLEASE PROVIDE A NOTE ON THE PLANS | | | INDICATING COMPLIANCE WITH SUCH PROVISION. | | | | | | 9. PLEASE NOTE THAT PURSUANT TO SECTION 5, CONDITION | | | #13 OF RESOLUTION NO. 97-17, WATER-SAVING PLUMBING | | | FIXTURES SHALL BE INSTALLED THROUGHOUT THE PROJECT. | | | PLEASE PROVIDE A NOTE ON THE PLANS INDICATING | | | COMPLIANCE WITH SUCH PROVISION. | | | | | | 10. ACCORDING TO THE CIVIL PLANS, THE PROPOSED PAVILION | | | BY THE POOL WILL BE LOCATED IN THE RELOCATED DRAINAGE | | | EASEMENT. PLEASE CLARIFY AND ADJUST ACCORDINGLY. | | | | | | 11. PLEASE PROVIDE A TURNING RADIUS ANALYSIS FOR THE | | | UTILIZATION OF THE LOADING AREA AND DUMPSTER/COMPACTOR. | | | | | | 12. PLEASE PROVIDE DETAILS/INFORMATION REGARDING WHAT | | | APPEARS TO BE GATES/FENCES IN FRONT OF THE RESIDENTIAL | | | UNITS ALONG CENTREPARK BOULEVARD. ALL FENCING SHALL BE | | | CLEARLY DETAILED AND/OR LABELED WITH APPLICABLE | | | HEIGHTS, ETC. | | | | | | 13. PURSUANT TO RESOLUTION NO. 97-17, THE SETBACK ALONG | | | AUSTRALIAN AVENUE SHALL BE A MINIMUM OF 20 FEET; THE | | | PROPOSED SITE PLAN INDICATES ON 19 FEET BEING PROVIDED. | | | | | | 14. CONSIDER REDUCING THE WIDTH OF THE ENTRANCE/EXIT | | | DRIVE FROM THE GARAGE TO 20 FEET. AS SUCH, THE OPENING | | | IN THE BUILDING CAN BE REDUCED AS WELL. | | | | | | 15. THE DESIGN OF THE GROUNDFLOOR UNITS SHOULD BE | | | MODIFIED SUCH THAT THEY HAVE A WALK-UP ENTRANCE WITH | | | FRONT DOOR FACING THE STREET, ETC. THE CURRENT DESIGN | | | IS SUCH THAT IT APPEARS TO BE ONLY A SIDEWALK LEADING | | | TO A BACK PATIO/SLIDING DOOR. | | | | | | 16. THERE ARE STRUCTURAL ELEMENTS SHOWN WITHIN THE | | | REQUIRED SETBACK, SPECIFICALLY AT THE SOUTH END OF THE | | | BUILDING. ONLY ROOF OVERHANGS, BALCONIES, ETC. MAY | | | ENCROACH INTO A REQUIRED SETBACK. | | | | | | 17. AS THE BUILDING IS LOCATED AT THE PROPERTY LINE AND | | | THERE APPEAR TO BE BALCONIES AND ROOF OVERHANGS | | | ENCROACHING INTO THE REQUIRED SETBACK, PLEASE ENSURE | | | THAT ALL PLANS CLEARLY IDENTIFY THE ENCROACHMENTS AND | | | ARE DIMENSIONED ACCORDINGLY. THE ELEVATIONS APPEAR TO | | | SHOW OVERHANGS ON THE UPPER FLOOR THAT ARE NOT SHOWN ON | | | THE ROOF PLAN AND/OR FLOOR PLANS. ENSURE THAT OVERHANGS | | | DO NOT PROJECT MORE THAN 3 FEET INTO THE REQUIRED | | | SETBACK. | | | | | | 18. THE ENTRANCE TO THE GARAGE ON THE ELEVATIONS DOES | | | NOT APPEAR TO MATCH THAT WHICH IS SHOWN ON THE | | | SITE/FLOOR PLAN. PLEASE ENSURE THAT ALL PLANS ARE | | | CONSISTENT. | | | | | | 19. A DETAIL SHALL BE PROVIDED FOR THE PROPOSED BIKE | | | RACKS. | | | | | | 20. FOR THE PUBLIC SIDEWALK ALONG CENTREPARK BOULEVARD, | | | CONSIDER HAVING IT AS A STRAIGHT WALK, AS OPPOSED TO | | | CONTOURING IT WITH THE CURB LINE. IN THOSE AREAS WHERE | | | THERE IS NO ON-STREET PARKING, THIS WOULD ALLOW | | | LANDSCAPING/TREES TO BE PLACE ON BOTH SIDES OF THE WALK | | | AND ALONG THE STREET. THIS SHOULD PROBABLY BE DISCUSSED | | | IN A BIGGER CONTEXT WITH THE PROPERTY OWNER?S | | | ASSOCIATION/ARCHITECTURAL REVIEW COMMITTEE AS THE | | | EXISTING PALMS ARE PART OF AN OVERALL EXISTING THEME | | | ALONG THE ROADWAY. | | | | | | 21. THE APPLICANT SHOULD WORK WITH THE PROPERTY OWNER?S | | | ASSOCIATION REGARDING ENHANCEMENT OF THE CENTREPARK | | | ENTRANCE (AT THE CORNER OF AUSTRALIAN AVENUE AND | | | CENTREPARK BOULEVARD) AS THE PROPOSED PROJECT WILL BE | | | REMOVING THE EXISTING ENTRANCE WALL, ROYAL PALMS, ETC. | | | | | | 22. ALL POOLS SHALL BE ENCLOSED BY A FENCE OR SIMILAR | | | STRUCTURE THAT IS AT LEAST 4 FEET IN HEIGHT. ACCESS TO | | | THE POOL MUST BE THROUGH A BUILDING OR THROUGH A | | | SELF-CLOSING AND SELF-LATCHING GATE WITH LATCHES AT | | | LEAST 54 INCHES ABOVE THE BOTTOM OF THE GATE. | | | | | | 23. STAFF WOULD LIKE TO DISCUSS THE ARCHIECTURAL DESIGN | | | OF THE BUILDING, SPECIFICALLY THE TREATMENT OF THE | | | PROMINENT CORNER OF THE BUILDING NEAR THE INTERSECTION | | | OF AUSTRALIAN AVENUE AND CENTREPARK BOULEVARD. PLEASE | | | NOTE, COLOR RENDERINGS WOULD PROVIDE USEFUL IN THE | | | EVALUATION OF THESE ASPECTS OF THE BUILDING. | | | ___________________________________________ | | | | | | NOTE, STAFF IS CONTINUING TO DISCUSS THE PROPOSED TEXT | | | AMENDMENT PERTAINING TO THE PARKING REQUIREMENTS AND | | | WILL FOLLOW UP SOON IN THAT REGARD TO DISCUSS THE | | | SPECIFIC LANGUAGE, AS WELL AS ANY POTENTIAL IMPACTS TO | | | THE PROJECT (IF ANY). | | | ___________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | F) IN ORDER TO BE CONSIDERED FOR THE OCTOBER 16, 2018, | | | PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE | | | SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED | | | DOCUMENTS/PLANS NO LATER THAN AUGUST 24, 2018. NOTE | | | THAT THE DATE OF THE OCTOBER PLANNING BOARD MEETING MAY | | | CHANGE AS A RESULT OF WORK OCCURRING IN THE CITY | | | COMMISSION CHAMBERS. | | | | | | G) TO BE PLACED ON THE OCTOBER 16, 2018, PLANNING BOARD | | | AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO LATER | | | THAN OCTOBER 1, 2018. SIGNAGE SHALL CONFORM AND BE | | | INSTALLED WITH THE REQUIREMENTS OF THE CITY?S ZONING | | | AND LAND DEVELOPMENT REGULATIONS, AS ALSO PROVIDED IN | | | THE DEVELOPMENT APPLICATION. A SIGNED AND NOTARIZED | | | AFFIDAVIT SHALL BE PROVIDED BY THE DEADLINE REFERENCED | | | ABOVE. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| |