| Plan Review Stops For Project Z17120029 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
01-09-2018 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
01-09-2018 |
Time |
23:14 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
01-09-2018 |
Time |
23:14 |
Sent To |
|
|
| Notes |
| 2018-01-09 23:19:46 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. WHEN SUBMITTED FOR PERMIT, THE PLANS SHALL CLEARLY | | | SHOW THE ACCESSIBLE ROUTE FROM THE PROPOSED NEW CANOPY | | | TO THE BUILDING ENTRANCES. THE PLANS AS SUBMITTED, | | | INDICATE THE RAMP ONLY AS A NOTE (NOTE 17) ON SHEET | | | A1.101, CONSTRUCTION PLAN - PLAZA. | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
P |
Date |
01-08-2018 |
|
|
Cont ID |
|
| Sent By |
squinone |
Date |
01-08-2018 |
Time |
|
Rev Time |
0.00 |
| Received By |
squinone |
Date |
01-02-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-01-08 12:00:08 | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | DATE: 01/08/2018 | | | PROJECT: PHILLIPS POINT | | | ADDRESS: 777 S. FLAGLER DR. | | | STATUS: PASSED | | | | | | THIS IS AN INITIAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS, AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. NO CIVIL ENGINEERING PLANS WERE | | | SUBMITTED IN THE INITIAL SITE PLAN PACKAGE. | | | | | | AFTER THE SITE PLAN IS APPROVED, IN THE NEXT PHASE, THE | | | FOLLOWING GENERAL COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL: | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED FROM THE FOLLOWING WEBSITE LINK: | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | 2. PLEASE SUBMIT THE LATEST VERSION OF THE 'AUTO-CALC | | | CERTIFIED COST ESTIMATE FORM' FOR SUBMISSION TO CITY OF | | | WEST PALM BEACH PUBLIC WORKS DEPARTMENT FOR ADDITIONAL | | | WORK PROPOSED. THIS FORM CAN BE DOWNLOADED FROM THE | | | FOLLOWING LINK: | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | 3. PLEASE INCLUDE THE LATEST VERSION OF THE APPLICABLE | | | CITY OF WEST PALM BEACH STANDARD UTILITY DETAILS TO THE | | | DETAIL SHEET/S DURING SUBMISSION OF THE FINAL | | | ENGINEERING PLANS. CONTACT THE ENGINEERING SERVICES | | | DEPARTMENT FOR THE LATEST REVISED DETAILS IN CAD | | | FORMAT. CITY'S STANDARD DETAILS (IN PDF FILE FORMAT) | | | CAN BE DOWNLOADED FROM THE FOLLOWING SITE: HTTP://WPB.O | | | RG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PERMITS- | | | APPLICATIONS | | | | | | SOFIA QUINONES-BENEJAM, EI | | | PROJECT ENGINEER | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33402 | | | (MAILING ADDRESS: PO BOX 3366) | | | P: 561.494.1108 | | | C: 561.459.6518 | | | F: 561.494.1116 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
01-05-2018 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
01-05-2018 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
01-05-2018 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2018-01-05 13:20:50 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 4. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 5. THE EXISTING FIRE SPRINKLER SYSTEM AND/OR FIRE | | | ALARM(IF APPLICABLE) SHALL BE EXTENDED INTO OR UNDER | | | ALL NEW STURCTURES. ANY WORK ON THE LIFE SAFETY SYSTEMS | | | SHALL BE DONE BY CERTIFIED LIFE SAFETY CONTRACTORS | | | UNDER SPEARATE SHOP DRAWINGS. | | | | | | 6. FOR PLAN SUBMITTAL PURPOSES, PLEASE PROVIDE HOW ALL | | | EXISTING EXITING WILL BE MAINTAINED OR MODIFIED DURING | | | ALL CONSTRUCTION AND/OR PHASES. | | | | | | 7. FOR PLAN SUBMITTAL PURPOSES, PLEASE ENSURE THAT THE | | | HEIGHT OF THE CANOPY MEETS THE MINIMUM HEIGHT | | | REQUIREMENT OF 13'6" FOR FIRE APPARATUS. | | | | | | 8. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES | | | NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 9. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS | | | AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
04-26-2018 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
04-26-2018 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
04-26-2018 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2018-04-26 16:05:36 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: PHILLIPS POINT PD Z17120029 | | | APRIL 26, 2018 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PLEASE REVISE THE TREE DISPOSITION CHART | | | TO ADD A COLUMN SHOWING WHETHER THE TREE WILL BE | | | RELOCATED, PRESERVED IN PLACE OR REMOVED. PLEASE | | | PROVIDE A TREE MITIGATION CHART SHOWING THE TOTAL | | | CANOPY REMOVED AND THE MITIGATION PROVIDED. | | | | | | 2. SATISFIED. THE ROYAL PALMS SHOULD BE RELOCATED TO | | | ANOTHER LOCATION ON THE PROPERTY OR TO A PUBLIC | | | LOCATION SPECIFIED BY THE CITY RATHER THAN BEING | | | DESTROYED. THE HEALTH AND CONDITION OF THE PALMS SHOULD | | | BE ASSESSED, AND FOUR MATCHING PALMS IN THE BEST | | | CONDITION SHOULD BE USED ALONG LAKEVIEW. | | | | | | 3. SATISFIED. PLEASE SHOW COMPLIANCE WITH SECTION | | | 94-442(G), FLORIDA FRIENDLY LANDSCAPE REQUIREMENTS. | | | | | | 4. SATISFIED. PLEASE SHOW LOCATIONS OF ANY WATER AND | | | SEWER LINES ON THE LANDSCAPE PLAN AND RESOLVE CONFLICTS | | | WITH LANDSCAPING. | | | | | | 5. SATISFIED. PLEASE PROVIDE A COMPARISON BETWEEN THE | | | NUMBER OF TREES AND SHRUBS PROVIDED IN THE LIMITS OF | | | WORK AND THE NUMBER SHOWN ON THE APPROVED LANDSCAPE | | | PLANS. | | | | | | 6. SATISFIED. PLEASE PROVIDE INFORMATION ON HOW THE | | | REST OF THE SITE WILL BE REVIEWED TO SHOW ALL TREES AND | | | SHRUBS ARE IN COMPLIANCE WITH THE APPROVED PLANS. IF | | | ANY CHANGES ARE NEEDED TO ADJUST SPECIES FOR | | | REPLACEMENT OF MISSING MATERIAL, THEY SHOULD BE | | | ADDRESSED IN THIS PETITION. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
01-08-2018 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-08-2018 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-08-2018 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2018-01-08 17:45:37 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: PHILLIPS POINT PD Z17120029 | | | JANUARY 8, 2018 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PLEASE REVISE THE TREE DISPOSITION CHART TO ADD A | | | COLUMN SHOWING WHETHER THE TREE WILL BE RELOCATED, | | | PRESERVED IN PLACE OR REMOVED. PLEASE PROVIDE A TREE | | | MITIGATION CHART SHOWING THE TOTAL CANOPY REMOVED AND | | | THE MITIGATION PROVIDED. | | | | | | 2. THE ROYAL PALMS SHOULD BE RELOCATED TO ANOTHER | | | LOCATION ON THE PROPERTY OR TO A PUBLIC LOCATION | | | SPECIFIED BY THE CITY RATHER THAN BEING DESTROYED. THE | | | HEALTH AND CONDITION OF THE PALMS SHOULD BE ASSESSED, | | | AND FOUR MATCHING PALMS IN THE BEST CONDITION SHOULD BE | | | USED ALONG LAKEVIEW. | | | | | | 3. PLEASE SHOW COMPLIANCE WITH SECTION 94-442(G), | | | FLORIDA FRIENDLY LANDSCAPE REQUIREMENTS. | | | | | | 4. PLEASE SHOW LOCATIONS OF ANY WATER AND SEWER LINES | | | ON THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH | | | LANDSCAPING. | | | | | | 5. PLEASE PROVIDE A COMPARISON BETWEEN THE NUMBER OF | | | TREES AND SHRUBS PROVIDED IN THE LIMITS OF WORK AND THE | | | NUMBER SHOWN ON THE APPROVED LANDSCAPE PLANS. | | | | | | 6. PLEASE PROVIDE INFORMATION ON HOW THE REST OF THE | | | SITE WILL BE REVIEWED TO SHOW ALL TREES AND SHRUBS ARE | | | IN COMPLIANCE WITH THE APPROVED PLANS. IF ANY CHANGES | | | ARE NEEDED TO ADJUST SPECIES FOR REPLACEMENT OF MISSING | | | MATERIAL, THEY SHOULD BE ADDRESSED IN THIS PETITION. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
P |
Date |
05-31-2018 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
05-31-2018 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
05-31-2018 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
01-09-2018 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
01-09-2018 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
01-09-2018 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2018-01-09 14:32:39 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP:// | | | WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER | | | MITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. NEW FEMA FIRM MAPS AND TWO FEET OF FREEBOARD ABOVE | | | BASE FLOOD ELEVATION FOR STRUCTURES IN SPECIAL FLOOD | | | HAZARD AREA ARE NOW IN EFFECT. THE MAPS ARE AVAILABLE | | | AT HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX? | | | | | | 2. UPDATE THE FLOOD ZONE INFORMATION ON THE SURVEY. | | | | | | 3. LAKEVIEW AVENUE IS MAINTAINED BY FDOT. | | | | | | 4. THE CITY HAS A SANITARY SEWER PROJECT PLANNED FOR | | | LAKEVIEW AVE AND CHASE STREET. CONTACT SUZANNE BERGLUND | | | (TELEPHONE NUMBER 561-494-1075) FOR INFORMATION. | | | | | | 5. USE THE LATEST CITY DETAILS. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
P |
Date |
01-05-2018 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
01-05-2018 |
Time |
07:32 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2018-01-05 07:33:04 | PASSED WITH COMMENT THAT FDOT PERMIT MAY BE REQUIRED. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2018-04-30 16:36:50 | PASSED WITH CONDITION. CONSIDER REMOVING A PORTION OF | | | THE SIDEWALK AT THE BACK OF CURB EAST AND WEST OF THE | | | DROP OFF AREA AND ADDING A PLANTING AREA AT THE BACK OF | | | CURB. THIS WOULD ASSIST IN DIRECTING PEDESTRIANS | | | TOWARDS THE NEW SIDEWALK LOCATED BEHIND THE PALMS IN | | | THE DROP OFF AREA. | | | | | | ERIK D. FERGUSON, P.E. | | | CITY TRANSPORTATION ENGINEER | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
01-09-2018 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2018-01-09 18:06:15 | 1) THE ENGINEERING PLAN BY KIMLEY HORN DOESN'T PROVIDE | | | SUFFICIENT DETAIL FOR THE PROPOSED SIDWALK ALONG | | | LAKEVIEW TO REVIEW. | | | 2) A FDOT PERMIT WILL BE REQUIRED FOR WORK IN THE | | | LAKEVIEW RIGHT OF WAY. | | | 3) WEST PALM BEACH UTILITIES IS PROPOSING TO REPLACE | | | THE SANITARY SEWER ALONG LAKEVIEW THIS SUMMER. PLEASE, | | | COORDINATE. | | | 4) THE CITY IS PROPOSING TO REDUCE THIS PORTION OF LAKE | | | AVENUE TO TWO TRAVEL LANES WITH PARKING AND BIKE LANES. | | | | | | ERIK D. FERGUSON, P.E. | | | CITY TRANSPORTATION ENGINEER | | | [email protected] | | | 561-494-1092 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
01-10-2018 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
01-10-2018 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
01-10-2018 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2018-01-10 12:43:47 | 1. PLEASE PROVIDE A DETAIL ACCOUNT FOR BUILDING SQUARE | | | FOOTAGE LISTING PROPOSED LOBBY ADDITION AND REFERENCED | | | CONVERTED MECHANICAL SPACE. GSF TABLE. | | | 2. PLEASE PROVIDE A FULL PHOTOMETRIC PLAN OF THE | | | LAKEVIEW FRONTAGE TO CONFIRM COMPLIANCE WITH MINIMUM | | | 0.6 FOOTCANDLE REQUIRED BY CODE. | | | 3. DESIGN SHALL FIRST EXPLORE MAINTAINING THE ROYAL | | | PALMS CLOSER TO THE CURB TO PROTECT PEDESTRIANS. A | | | NARROWER HEDGE CAN BE LOCATED BETWEEN SIDEWALK AND | | | DROP-OFF AREA. | | | 4. FOLLOWIGN THE DESIRE TO IMPROVE THE PEDESTRIAN | | | ENVIRONMENT STAFF RECOMMENDS THE APPLICANT TO EXPLORE | | | THE ADDITION OF SOME SMALL SHADE TREES WITHIN THE | | | EXISTING PLANTING AREA NEXT TO BUILDING ARCADE ALONG | | | LAKEVIEW AVE. | | | 4. PROPOSED CHANGES ARE A GOOD OPPORTUNITY TO EXECUTE A | | | MAINTENANCE AGREEMENT FOR THE ENTIRE PROJECT AND | | | DISCUSS THE TRINITY PARK MAINTENANCE. | | | 5. DRO-OFF AREA SHALL NOT BE USED AS A SURFACE PARKING | | | LOT. | | | |
|
|
| |
Print |