Plan Review Details - Project Z17120024
| Plan Review Stops For Project Z17120024 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
01-09-2018 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
01-09-2018 |
Time |
22:57 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
01-09-2018 |
Time |
22:57 |
Sent To |
|
|
| Notes |
| 2018-01-09 23:00:53 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR THE BUILDING PERMIT APPLICATION. | | | | | | 2. THE ADDITION TO THE EXISTING BUILDING IS COVERED BY | | | CHAPTER 11 OF THE FLORIDA EXISTING BUILDING CODE. THE | | | HEIGHT AND/OR AREA INCREASE DUE TO THE PROPOSED | | | ADDITION SHALL NOT INCREASE THE TOTAL BUILDING HEIGHT | | | AND/OR AREA BEYOND THAT ALLOWED UNDER THE APPLICABLE | | | PROVISIONS OF CHAPTER 5 OF THE FLORIDA BUILDING CODE | | | FOR THE TYPE OF CONSTRUCTION USED. | | | | | | 3. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND | | | OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF | | | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE | | | VERIFIED. | | | | | | 4. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, | | | FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, | | | GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, | | | SITE IRRIGATION, ETC. | | | | | | 5. THIS PROJECT WILL BE SUBJECT TO ART IN PUBLIC PLACES | | | (AIPP) ASSESSMENT. FOR ADVICE ON THE PROVISION OF | | | PUBLIC ARTWORK IN LIEU OF THE AIPP ASSESSMENT, CONTACT | | | SYBILLE WELTER, ART IN PUBLIC PLACES COORDINATOR, AT | | | (561) 822-1521, OR BY EMAIL: [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
01-08-2018 |
|
|
Cont ID |
|
| Sent By |
squinone |
Date |
01-08-2018 |
Time |
|
Rev Time |
0.00 |
| Received By |
squinone |
Date |
01-02-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-01-08 11:41:57 | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | DATE: 01/08/2018 | | | PROJECT: REHAB CENTER OF THE PALM BEACHES | | | ADDRESS: 301 NORTHPOINT PARKWAY | | | STATUS: FAILED | | | | | | THIS IS AN INITIAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS, AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. | | | | | | NO CIVIL ENGINEERING PLANS WERE SUBMITTED IN THE | | | INITIAL SITE PLAN PACKAGE INDICATING STORMWATER CONTROL | | | AND PLANS FOR WATER AND SEWER SERVICES/CONNECTIONS FOR | | | THE PROPOSED DEVELOPMENT. FOLLOWING COMMENTS NEED TO BE | | | ADDRESSED PRIOR TO SITE PLAN APPROVAL: | | | | | | 1. PLEASE SHOW ON THE PLANS, HOW WILL THE SITE/BUILDING | | | BE SERVED FOR WATER, SEWER AND FIRE PROTECTION. SHOW | | | ALL EXISTING UTILITIES WITHIN THE VICINITY OF THE | | | PROPOSED SITE AS WELL AS PROPOSED UTILITIES TO SERVE | | | THE DEVELOPMENT (LABEL SIZE AND MATERIAL OF ALL PIPES | | | AND CONDUITS ETC.); | | | | | | 2. SUBMIT ESTIMATES FOR WATER AND FIRE DEMAND, BOTH | | | AVERAGE AND PEAK FLOW WITH PEAKING FACTOR. ALSO SUBMIT | | | ESTIMATES OF SANITARY SEWER FLOW FOR THE PROPOSED | | | DEVELOPMENT. SHOW PROJECTED DEMANDS ON THE UTILITY PLAN | | | SHEET; | | | | | | 3. THE EXISTING 8-INCH PRIVATE FIRELINE MUST HAVE A TWO | | | DCDA CLOSE TO THE RIGHT-OF-WAY; | | | | | | 4. PLACEMENT OF THE ANY PROPOSED METER, BACKFLOW | | | PREVENTER, DCDA ETC. SHALL BE INSTALLED PER THE CITY'S | | | STANDARD DETAILS. WATER METER SHOULD BE WITHIN THE | | | RIGHT-OF-WAY OR INSIDE AN 'UTILITY EASEMENT' JUST | | | INSIDE THE PROPERTY NEAR THE RIGHT-OF-WAY AND | | | ACCESSIBLE; | | | | | | 5. SHOW EXISTING 8-INCH DIP WATER STUB AND EXISTING | | | 6-INCH SANITARY SEWER LATERAL STUB ON THE WEST SIDE OF | | | THE PROPERTY; | | | | | | 6. ON THE LANDSCAPING PLAN, WHEN SUBMITTED IN THE NEXT | | | REVIEW PHASE, SHOW LOCATIONS OF ALL WATER METERS, | | | VALVES, CLEAN-OUTS, LIGHT POLES, ETC. ROOT BARRIERS MAY | | | BE REQUIRED WHERE PLANTINGS ARE NEAR UNDERGROUND | | | STORMWATER, SANITARY, OR POTABLE WATER LINES. ALSO | | | CLEARLY INDICATE ALL EXISTING AND PROPOSED EASEMENTS ON | | | THE LANDSCAPE PLAN; | | | | | | 7. PLEASE ALSO SHOW ON THE LANDSCAPE PLAN, WHEN | | | SUBMITTED IN THE NEXT REVIEW PHASE, SHOW THE SIGHT | | | TRIANGLES FOR THE ALL VEHICULAR EXITS FROM THE SITE. | | | (SECTION 94-305E, CODE OF ORDINANCES); | | | | | | 8. PLEASE PROVIDE AN AUTOTURN ANALYSIS DEMONSTRATING | | | THE SOLID WASTE COLLECTION VEHICLE CAN ACCESS AND | | | MANEUVER WITHIN THE PROPOSED DEVELOPMENT; | | | | | | AFTER THE SITE PLAN IS APPROVED, IN THE NEXT PHASE, THE | | | FOLLOWING GENERAL COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL: | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED FROM THE FOLLOWING WEBSITE LINK: | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | 2. PLEASE SUBMIT THE LATEST VERSION OF THE 'AUTO-CALC | | | CERTIFIED COST ESTIMATE FORM' FOR SUBMISSION TO CITY OF | | | WEST PALM BEACH PUBLIC WORKS DEPARTMENT FOR ADDITIONAL | | | WORK PROPOSED. THIS FORM CAN BE DOWNLOADED FROM THE | | | FOLLOWING LINK: | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | 3. FOR THE FINAL WATER AND SEWER PLANS, INCLUDE A NOTE | | | THAT: AS OF DECEMBER 20, 2015 THE CITY OF WEST PALM | | | BEACH CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD | | | FREE." FOR MORE INFORMATION REFER TO THE LINK BELOW: HT | | | TP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLICA | | | TIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | | | | SOFIA QUINONES-BENEJAM, EI | | | PROJECT ENGINEER | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33402 | | | (MAILING ADDRESS: PO BOX 3366) | | | P: 561.494.1108 | | | C: 561.459.6518 | | | F: 561.494.1116 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
01-05-2018 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
01-05-2018 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
01-05-2018 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2018-01-05 08:59:55 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE HOW THE | | | EXISTING OCCUPANCY WILL BE MAINTAINED AND SEPARATED | | | FROM THE CONSTRUCTION AREAS. | | | ALL LIFE SAFETY SYSTEMS OF THE EXISTING OCCUPANCY SHALL | | | BE MAINTAINED THROUGHOUT THE CONSTRUCTION PERIOD. | | | | | | 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT ALL | | | LIFE SAFETY SYSTEMS ARE EXTENDED INTO THE NEW SPACE AND | | | ARE CODE COMPLIANT. | | | | | | 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER | | | THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY | | | ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM, | | | ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND | | | SUBMITTED WITH THE MASTER PLAN. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. IT IS HIGHLY RECOMMENDED FOR ANY ACCESS GATES THAT | | | THEY BE PROVIDED WITH KNOX KEY ACCESS LOCKS, PADLOCKS | | | AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
01-08-2018 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-08-2018 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-08-2018 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2018-01-08 16:53:35 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: THE REHAB CENTER Z17120024 | | | JANUARY 8, 2018 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PLEASE REVISE THE TREE TABULAR CHART AND TREE | | | SUMMARY CHART TO MATCH THE INDIVIDUAL AND TOTAL TREE | | | MITIGATION CALCULATIONS OF THE REPLACEMENT AND REMOVAL | | | CHARTS. | | | | | | 2. PLEASE PROVIDE A DETAILED EXPLANATION OF WHY THE | | | LIVE OAKS AND MAHOGANY TREES ON SITE CANNOT BE | | | RELOCATED. | | | | | | 3. PLEASE PROVIDE LOCATIONS OF LIGHTING ON THE | | | LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING. | | | | | | 4. PLEASE SHOW LOCATIONS OF WATER AND SEWER LINES ON | | | THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH | | | LANDSCAPING. | | | | | | 5. PLEASE PROVIDE A COMPARISON BETWEEN THE NUMBER OF | | | TREES AND SHRUBS PROVIDED IN THE LIMITS OF WORK AND THE | | | NUMBER SHOWN ON THE APPROVED LANDSCAPE PLANS. | | | | | | 6. PLEASE PROVIDE INFORMATION ON HOW THE REST OF THE | | | SITE WILL BE REVIEWED TO SHOW ALL TREES AND SHRUBS ARE | | | IN COMPLIANCE WITH THE APPROVED PLANS. IF ANY CHANGES | | | ARE NEEDED TO ADJUST SPECIES FOR REPLACEMENT OF MISSING | | | MATERIAL, THEY SHOULD BE ADDRESSED IN THIS PETITION. | | | | | | 7. PLEASE CORRECT THE TREE PROTECTION NOTES TO READ | | | ?CITY OF WEST PALM BEACH?, AND PROVIDE A TREE | | | PROTECTION DETAIL. | | | | | | 8. PLEASE REVISE THE FLORIDA FRIENDLY DESIGN OPTIONS TO | | | MATCH CURRENT CODE- GROUNDCOVER OR GRASS AREAS, AND | | | REVISE THE POINTS TAKEN, AS PLANTS CANNOT BE COUNTED | | | TWICE. 51 PERCENT TAKEN IN ONE CATEGORY DISALLOWS 51 | | | PERCENT TAKEN IN THE SAME CATEGORY. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
01-09-2018 |
|
|
Cont ID |
|
| Sent By |
|
Date |
01-09-2018 |
Time |
|
Rev Time |
1.00 |
| Received By |
|
Date |
01-08-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-01-09 08:13:52 | WE NEED A SOLID WASTE DISPOSAL PLAN IDENTIFIEDFOR THE | | | FACILITY. |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
01-09-2018 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
01-09-2018 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
01-09-2018 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2018-01-09 14:30:04 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP:// | | | WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER | | | MITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. NEW FEMA FIRM MAPS AND TWO FEET OF FREEBOARD ABOVE | | | BASE FLOOD ELEVATION FOR STRUCTURES IN SPECIAL FLOOD | | | HAZARD AREA ARE NOW IN EFFECT. THE MAPS ARE AVAILABLE | | | AT HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX? | | | | | | 2. CONFLICTING VERTICAL DATUMS: TOPOGRAPHIC AND | | | BOUNDARY SURVEY LISTS THE VERTICAL DATUM AS NAVD 1988. | | | PRELMINARY ENGINEERING PLAN LISTS THE VERTICAL DATUM AS | | | NGVD 1929. PER SECTION 78-9 OF THE CODE OF ORDINANCES, | | | THE VERTICAL DATUM FOR THE CITY IS NGVD 1929. THE CITY | | | HAS BEEN PERMITTING THE USE OF NAVD 1988 PROVIDED THE | | | CONVERSION BETWEEN NGVD AND NAVD IS PROVIDED ON THE | | | SURVEY/PLANS. | | | | | | 3. SHOW UTILITIES ON THE LANDSCAPE PLANS. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. SFWMD ERP WILL NEED TO BE MODIFIED. | | | | | | 3. NPBCID PERMIT, IF APPLICABLE, MAY NEED TO BE | | | MODIFIED. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
01-05-2018 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
01-05-2018 |
Time |
07:19 |
Rev Time |
|
| Received By |
vnoel |
Date |
01-05-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-01-05 07:31:12 | 1. DUMPSTER DETAIL INCLUDED BUT NO DUMPSTER SHOWN ON | | | SITE PLAN. | | | 2. SITE/CIVIL PLANS WILL NEED SUBMITTED TO ENGINEERING | | | SERVICES. | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
01-09-2018 |
|
|
Cont ID |
|
| Sent By |
|
Date |
01-09-2018 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
01-09-2018 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-01-09 17:47:48 | 1) PROVIDE TRAFFIC IMPACT STATEMENT. | | | 2) PROVIDE COUNTY TRAFFIC CONCURRENCY LETTER. | | | | | | ERIK D. FERGUSON, P.E. | | | CITY TRANSPORTATION ENGINEER | | | [email protected] | | | 561-494-1092 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
01-10-2018 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
01-10-2018 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
01-10-2018 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2018-01-10 09:02:59 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 01.10.2018 | | | PROJECT NO.: Z17120024 | | | CASE NO.: PB 862Y | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. PURSUANT TO ORDINANCE NO. 2804-95, THE BUILD-OUT | | | DATE FOR THE NORTHPOINTE DRI WAS NOVEMBER 30, 2000. | | | STAFF IS CONTINUING TO REVIEW AND DETERMINE THE | | | IMPLICATIONS OF THE EXPIRATION OF THE DRI AND WHAT | | | STEPS ARE NECESSARY TO ALLOW FOR FUTURE DEVELOPMENT. | | | | | | 2. A REVIEW OF THE PREVIOUSLY-APPROVED LANDSCAPE PLANS | | | SHALL BE COMPLETED. ANY LANDSCAPE MATERIAL THAT IS | | | MISSING OR OTHERWISE NEEDS TO BE REPLACED SHALL BE | | | INCORPORATED INTO THE SCOPE OF THE PROPOSED PROJECT. | | | | | | 3. APPROVED TRAFFIC CONCURRENCY SHALL BE PROVIDED. | | | | | | 4. FLOOR PLANS SHALL BE PROVIDED. | | | | | | 5. ALL UTILITY LETTERS SHALL BE PROVIDED. | | | | | | 6. THE SURVEY SHOULD BE AN ALTA/ACSM LAND TITLE SURVEY | | | AND PROVIDE ALL OF THE MINIMUM STANDARDS LISTED IN THE | | | DEVELOPMENT APPLICATION. THE SURVEY SHOULD BE | | | ACCOMPANIED BY A CURRENT OWNERSHIP AND ENCUMBRANCE | | | (O&E) REPORT, WHICH SHALL INCLUDE ALL EASEMENT AND | | | RESTRICTIONS OF RECORD, OR A CURRENT TITLE POLICY. | | | | | | 7. PLEASE REMOVE THE TREE DISPOSITION INFORMATION FROM | | | THE SITE PLAN; THIS SHOULD BE ACCOUNTED FOR ON A | | | SEPARATE PLAN AND/OR LANDSCAPE PLAN. | | | | | | 8. THE LINE WORK ON THE SITE PLAN NEEDS TO BE CORRECTED | | | IN THE AREA OF THE NEW PARKING SPACES. | | | | | | 9. PLEASE CLARIFY WHY THE SIDEWALK AT THE WEST END OF | | | THE PROPOSED PARKING IS SO WIDE; ADDITIONALLY, THERE IS | | | A SIGN SHOWN IN THE MIDDLE OF THE SIDEWALK. THE | | | SIDEWALK SHOULD LINE UP WITH THE EXISTING WALKWAY THAT | | | LEADS FROM NORTHPONT PARKWAY. | | | | | | 10. PLEASE IDENTIFY THE LOCATION OF EXISTING DUMPSTERS, | | | AND ENSURE THEIR COMPLIANCE WITH THE MINIMUM SCREENING | | | REQUIREMENTS. ADDITIONALLY, VERIFY THAT NO ADDITIONAL | | | DUMPSTERS ARE NEEDED TO ACCOMMODATE THE PROPOSED | | | EXPANSION. | | | | | | 11. DIMENSIONS SHALL BE PROVIDED FOR THE DRIVE AISLE | | | ADJACENT TO THE PROPOSED PARKING. ADDITIONALLY, THE | | | PROPOSED PARKING SPACES AND LANDSCAPE ISLANDS SHALL BE | | | DIMENSIONED TO ENSURE COMPLIANCE WITH THE MINIMUM | | | STANDARDS OF THE ZLDRS. | | | | | | 12. DIMENSIONS SHALL BE PROVIDED FOR ALL SETBACKS | | | ASSOCIATED WITH THE PROPOSED EXPANSION; ON THE SETBACK | | | TO THE WEST PROPERTY LINE WAS PROVIDED. | | | | | | 13. PURSUANT TO THE NORTPOINTE DRI, A MINIMUM OF 50 | | | PERCENT OF ALL TREES SHALL BE NATIVE; PLEASE CONFIRM | | | THAT SUCH REQUIREMENT IS BEING MET. | | | | | | 14. PLEASE CONFIRM THAT THE SITE PLAN COMPLIES WITH | | | CONDITION #20 OF THE NORTHPOINTE DRI, SPECIFICALLY | | | RELATING TO ENERGY CONSERVATION MEASURES. | | | ___________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | F) IN ORDER TO BE CONSIDERED FOR THE MARCH 20, 2018, | | | PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE | | | SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED | | | DOCUMENTS/PLANS NO LATER THAN JANUARY 26, 2018. | | | | | | G) TO BE PLACED ON THE MARCH 20, 2018, PLANNING BOARD | | | AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO LATER | | | THAN MARCH 5, 2018. SIGNAGE SHALL CONFORM AND BE | | | INSTALLED WITH THE REQUIREMENTS OF THE CITY?S ZONING | | | AND LAND DEVELOPMENT REGULATIONS, AS ALSO PROVIDED IN | | | THE DEVELOPMENT APPLICATION. A SIGNED AND NOTARIZED | | | AFFIDAVIT SHALL BE PROVIDED BY THE DEADLINE REFERENCED | | | ABOVE. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| |