Plan Review Details - Project Z17120011
Plan Review Stops For Project Z17120011
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 01-09-2018 Cont ID  
Sent By rbrown Date 01-09-2018 Time 23:43 Rev Time 0.00
Received By rbrown Date 01-09-2018 Time 23:43 Sent To  
Notes
2018-01-09 23:50:25DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR THE BUILDING PERMIT APPLICATION.
  
 2. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE.
  
 3. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 4. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS,
 FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS,
 GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE,
 SITE IRRIGATION, ETC.
  
 5. EACH SEPARATE BUILDING SHALL HAVE A SEPARATE
 ADDRESS. FOR STREET ADDRESSING, CONTACT MICHAEL ORIO,
 GIS SUPPORT SPECIALIST, AT (561) 494 1080, OR BY EMAIL:
 [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 01-08-2018 Cont ID  
Sent By squinone Date 01-08-2018 Time   Rev Time 0.00
Received By squinone Date 01-02-2018 Time   Sent To  
Notes
2018-01-08 16:52:51CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT
 DATE: 01/08/2018
 PROJECT: CARP
 ADDRESS: 1626 OLD OKEECHOBEE RD
 STATUS: FAILED
  
 THIS IS AN INITIAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS, AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES. FOLLOWING COMMENTS NEED TO BE
 ADDRESSED PRIOR TO SITE PLAN APPROVAL:
  
 1. SHOW ALL EXISTING UTILITIES WITHIN THE VICINITY OF
 THE PROPOSED SITE AS WELL AS PROPOSED UTILITIES TO
 SERVE THE DEVELOPMENT (LABEL SIZE AND MATERIAL OF ALL
 PIPES AND CONDUITS ETC.);
  
 2. RELOCATE DCDA AND METER FROM PARKING LOT AREA;
  
 3. UPDATE TITLE BLOCK FROM 'BLVD' TO 'RD';
  
 4. EXISTING SANITARY SEWER LATERAL FROM ALPHA STREET
 MUST BE CUT AND CAPPED AT THE MANHOLE. MANHOLE MUST BE
 REHAB;
  
 5. SUBMIT ESTIMATES FOR WATER AND FIRE DEMAND, BOTH
 AVERAGE AND PEAK FLOW WITH PEAKING FACTOR. ALSO SUBMIT
 ESTIMATES OF SANITARY SEWER FLOW FOR THE PROPOSED
 DEVELOPMENT. SHOW PROJECTED DEMANDS ON THE UTILITY PLAN
 SHEET;
  
 6. ON THE LANDSCAPING PLAN, WHEN SUBMITTED IN THE NEXT
 REVIEW PHASE, SHOW LOCATIONS OF ALL WATER METERS,
 VALVES, CLEAN-OUTS, LIGHT POLES, ETC. ROOT BARRIERS MAY
 BE REQUIRED WHERE PLANTINGS ARE NEAR UNDERGROUND
 STORMWATER, SANITARY, OR POTABLE WATER LINES. ALSO
 CLEARLY INDICATE ALL EXISTING AND PROPOSED EASEMENTS ON
 THE LANDSCAPE PLAN;
  
 7. PLEASE ALSO SHOW ON THE LANDSCAPE PLAN, WHEN
 SUBMITTED IN THE NEXT REVIEW PHASE, SHOW THE SIGHT
 TRIANGLES FOR THE ALL VEHICULAR EXITS FROM THE SITE.
 (SECTION 94-305E, CODE OF ORDINANCES);
  
 AFTER THE SITE PLAN IS APPROVED, IN THE NEXT PHASE, THE
 FOLLOWING GENERAL COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL:
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED FROM THE FOLLOWING WEBSITE LINK:
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 2. PLEASE SUBMIT THE LATEST VERSION OF THE 'AUTO-CALC
 CERTIFIED COST ESTIMATE FORM' FOR SUBMISSION TO CITY OF
 WEST PALM BEACH PUBLIC WORKS DEPARTMENT FOR ADDITIONAL
 WORK PROPOSED. THIS FORM CAN BE DOWNLOADED FROM THE
 FOLLOWING LINK:
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 3. SUBMIT WITH THE ENGINEERING DEVELOPMENT APPROVAL
 APPLICATION SIGNED & SEALED ENGINEER/MEP WATER AND
 SANITARY SEWER CALCULATION (IN DETAIL I.E. AVERAGE AND
 PEAK WITH PEAKING FACTOR). SUBMIT CALCULATIONS TO
 VALIDATE METER SIZE SELECTION. SHOW THESE CALCULATIONS
 ON THE UTILITY PLAN SHEET AS WELL;
  
 4. CCTV MUST BE PROVIDED FROM MANHOLE TO MANHOLE WHERE
 THE PROPOSED SANITARY SEWER WILL BE LOCATED. CONTACT ME
 FOR THE MANHOLE NUMBER AND SUBMIT CD WITH THE
 ENGINEERING DEVELOPMENT APPROVAL APPLICATION.
 COORDINATE WITH UTILITIES O&M SANITARY SEWER
 SUPERINTENDENT CHARLES PHOENIX PROVIDE 48-HOUR NOTICE
 AND OBTAIN A RIGHT-OF-WAY PERMIT;
  
 5. ALL PROPOSED FIRE DEPARTMENT CONNECTIONS SHALL BE
 WITHIN 100 FEET OF A FIRE HYDRANT AND SHALL BE WITHIN
 AN EASEMENT WITHIN THE PROPERTY;
  
 6. PLEASE INCLUDE THE LATEST VERSION OF THE APPLICABLE
 CITY OF WEST PALM BEACH STANDARD UTILITY DETAILS TO THE
 DETAIL SHEET/S DURING SUBMISSION OF THE FINAL
 ENGINEERING PLANS. CONTACT THE ENGINEERING SERVICES
 DEPARTMENT FOR THE LATEST REVISED DETAILS IN CAD
 FORMAT. CITY?S STANDARD DETAILS (IN PDF FILE FORMAT)
 CAN BE DOWNLOADED FROM THE FOLLOWING SITE: HTTP://WPB.O
 RG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PERMITS-
 APPLICATIONS
  
 7. PLACEMENT OF THE ANY PROPOSED METER, BACKFLOW
 PREVENTER, DCDA ETC. SHALL BE INSTALLED PER THE CITY?S
 STANDARD DETAILS. WATER METER SHOULD BE WITHIN THE
 RIGHT-OF-WAY OR INSIDE AN 'UTILITY EASEMENT' JUST
 INSIDE THE PROPERTY NEAR THE RIGHT-OF-WAY AND
 ACCESSIBLE;
  
 8. IN THE FINAL PLANS, MUST PROVIDE UTILITY CONFLICT
 TABLE (BOTTOM AND TOP OF CROSSING PIPES) AT THE
 CONFLICT POINTS OF ALL WATER, STORM AND SANITARY SEWER
 PIPES AS WELL AS OTHER FRANCHISE UTILITIES. EXISTING
 UTILITIES WITHIN THE PROPOSED SANITARY SEWER LATERAL
 ARE TO BE VERIFIED VIA SOFTDIGS, PROVIDE ALL UTILITY
 CROSSING INFORMATION;
  
 9. IN THE FINAL PLANS, SHOW DIRECTION OF FLOW FOR THE
 EXISTING SANITARY SEWER. SHOW INVERT AT CONNECTION
 POINTS AND INCLUDE A PROFILE FOR THE PROPOSED SERVICE
 LATERAL WITH GROUND ELEVATIONS ABOVE THE PIPE;
  
 10. PAVEMENT RESTORATION FOR OPEN CUT/TRENCH FOR
 UTILITY CONNECTION WORKS WILL NEED TO BE IN ACCORDANCE
 WITH 2016 CITY STANDARD DETAIL GC-9. THE ROAD SHALL BE
 MILLED/RESURFACED FOR FULL LANE WIDTH OF THE TRAVEL
 LANE(S) ENCROACHED BY THE TRENCH AREA, INCLUDING A
 TRANSITION AREA OF 50 FEET ON EACH SIDE OF THE TRENCH.
 PLEASE SHOW ON THE FINAL PLANS THE EXTENT OF THE
 MILLING AND RESURFACING;
  
 11. SHOW ON THE FINAL PLANS SIZE AND MATERIAL OF ALL
 EXISTING UTILITIES ON OLD OKEECHOBEE ROAD AND ALPHA
 STREET INCLUDING BUT NOT LIMITED TO WATER, SEWER, GAS,
 UNDERGROUND ELECTRIC CONDUITS, VALVES, ETC. PLEASE
 IDENTIFY THE SOURCE OF THE AS-BUILT INFORMATION
 UTILIZED FOR THE POTABLE WATER, SANITARY SEWER, AND
 STORM SEWER DESIGN;
  
 12. FOR THE FINAL WATER AND SEWER PLANS, INCLUDE A NOTE
 THAT: AS OF DECEMBER 20, 2015 THE CITY OF WEST PALM
 BEACH CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED,
 MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD
 FREE." FOR MORE INFORMATION REFER TO THE LINK BELOW: HT
 TP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLICA
 TIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL
  
 SOFIA QUINONES-BENEJAM, EI
 PROJECT ENGINEER
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33402
 (MAILING ADDRESS: PO BOX 3366)
 P: 561.494.1108
 C: 561.459.6518
 F: 561.494.1116
 EMAIL: [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 05-21-2018 Cont ID  
Sent By pleduc Date 05-21-2018 Time 11:27 Rev Time 0.00
Received By pleduc Date 05-21-2018 Time 11:20 Sent To  
Notes
2018-05-21 11:25:36AFTER A REVIEW OF THE PPRC RESPONSE MEMO FROM PAUL
 GREILICH, SENIOR PLANNER, DATED MAY 11, 2018, AND THE
 DRAWING DOCUMENTS, THE PREVIOUSLY SUBMITTED FIRE
 PREVENTION BUREAU COMMENTS APPEAR TO HAVE BEEN
 ADDRESSED.
  
 HOWEVER, THE BUREAU'S APPROVAL OF THIS SUBMITTED
 PROJECT DOES NOT CONSTITUTE ITS FINAL REVIEW OR
 APPROVAL.
  
 THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT
 THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE
 REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 01-05-2018 Cont ID  
Sent By pleduc Date 01-05-2018 Time   Rev Time 0.00
Received By pleduc Date 01-05-2018 Time 16:09 Sent To  
Notes
2018-01-05 16:10:01THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A
 PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED
 TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE
 REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH
 THE 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE,
 INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES.
  
 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE
 OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE.
  
 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT AN
 ADEQUATE WATER SUPPLY IS EXISTING OR WILL BE PROVIDED.
  
 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED
 ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF
 FIRE PREVENTION.
  
 THE NEW FIRE HYDRANT(S) AND FDC'S PLANNED FOR THIS
 DEVELOPMENT ARE ACCEPTABLE.
  
 9. PROVIDE FOR A FIRE SPRINKLER AND/OR FIRE ALARM PER
 THE APPLICABLE OCCUPANCY CODE. FOR ANY LIFE SAFETY
 ENGINEERED SYSTEM, I.E FIRE SPRINKLER AND FIRE ALARM,
 ENSURE THEY COMPLY WITH THE REQUIREMENTS OF FS 61G AND
 SUBMITTED WITH THE MASTER PLAN.
  
 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL
 BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS,
 EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A
 PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE
 SAFETY FEATURES AND EQUIPMENT.
  
 11. IT IS HIGHLY RECOMMENDED FOR ANY ACCESS GATES THAT
 THEY BE PROVIDED WITH KNOX KEY ACCESS LOCKS, PADLOCKS
 AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS.
  
 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT
 DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL.
  
 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING
 PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH
 THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop L LANDSCAPING
Rev No 2 Status P Date 05-22-2018 Cont ID  
Sent By rcaranci Date 05-22-2018 Time 11:56 Rev Time 0.00
Received By rcaranci Date 05-22-2018 Time 11:56 Sent To  
Notes
2018-05-22 11:56:40FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: 1626 OKEECHOBEE RD Z17120011
 MAY 22, 2018
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. SATISFIED. PLEASE UPDATE PLAN TO CURRENT LANDSCAPE
 CODE AS OF APRIL 21, 2017. THESE UPDATES INCLUDE TREE
 AND FLOWERING TREE REQUIREMENTS, FLORIDA FRIENDLY
 LANDSCAPE REQUIREMENTS, AND SUBSTITUTION OF PALM TREES.
  
 2. SATISFIED. PLEASE COMPLETE THE TREE DISPOSITIONS ON
 THE TREE INVENTORY CHART.
  
 3. SATISFIED. PLEASE PROVIDE A DETAILED EXPLANATION OF
 WHY THE LIVE OAK #20 ON SITE CANNOT BE RELOCATED.
  
 4. SATISFIED. PLEASE PROVIDE LOCATIONS OF LIGHTING ON
 THE LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING.
  
 5. SATISFIED. PLEASE SHOW LOCATIONS OF WATER AND SEWER
 LINES ON THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH
 LANDSCAPING.
  
 6. SATISFIED. REVISE CALCULATIONS OF REQUIRED TREES AND
 SHRUBS TO CURRENT CODE, AND ADD THE REQUIRED TREES (2
 PER UNIT) PER SECTION 94-443(D).
  
 7. SATISFIED. PLEASE CORRECT CALCULATIONS FOR BUFFER
 TREE REQUIREMENTS FOR WEST PROPERTY LINE TO 7, AND
 PROVIDE THE REQUIRED TREES OR NUMBER OF SUBSTITUTE
 PALMS PER CURRENT CODE REQUIREMENTS (3:1).
  
 8. SATISFIED. PLEASE SHOW THE REQUIRED HEDGE FOR THE
 DUMPSTER ENCLOSURE.
  
 9. SATISFIED. PLEASE REMOVE THE CHART LABELED DESIGN
 OPTIONS, AS IT IS NO LONGER APPLICABLE, AND UPDATE THE
 FLORIDA FRIENDLY LANDSCAPE OPTIONS CHART.
  
 10. SATISFIED. IF THE PARKING IS TO REMAIN IN THE
 PROPOSED LOCATION, THE TERMINAL ISLAND LANDSCAPE MUST
 MEET CODE REQUIREMENTS.
  
 11. SATISFIED. THREE ILEX CASSINE ARE SHOWN ON THE
 PLAN, BUT NOT ON THE PLANT LIST. PLEASE REVISE.
 12. SATISFIED. PLEASE REVISE LANDSCAPE REQUIREMENT LIST
 #8 LIST TO SHOW CURRENT 12 FOOT MINIMUM TREE SIZES
 REQUIRED.
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 01-08-2018 Cont ID  
Sent By rcaranci Date 01-08-2018 Time 11:57 Rev Time 0.00
Received By rcaranci Date 01-08-2018 Time 11:57 Sent To  
Notes
2018-01-08 11:57:39FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: 1626 OKEECHOBEE RD Z17120011
 JANUARY 8, 2018
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. PLEASE UPDATE PLAN TO CURRENT LANDSCAPE CODE AS OF
 APRIL 21, 2017. THESE UPDATES INCLUDE TREE AND
 FLOWERING TREE REQUIREMENTS, FLORIDA FRIENDLY LANDSCAPE
 REQUIREMENTS, AND SUBSTITUTION OF PALM TREES.
  
 2. PLEAS COMPLETE THE TREE DISPOSITIONS ON THE TREE
 INVENTORY CHART.
  
 3. PLEASE PROVIDE A DETAILED EXPLANATION OF WHY THE
 LIVE OAK #20 ON SITE CANNOT BE RELOCATED.
  
 4. PLEASE PROVIDE LOCATIONS OF LIGHTING ON THE
 LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING.
  
 5. PLEASE SHOW LOCATIONS OF WATER AND SEWER LINES ON
 THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH
 LANDSCAPING.
  
 6. REVISE CALCULATIONS OF REQUIRED TREES AND SHRUBS TO
 CURRENT CODE, AND ADD THE REQUIRED TREES (2 PER UNIT)
 PER SECTION 94-44
  
 7. PLEASE CORRECT CALCULATIONS FOR BUFFER TREE
 REQUIREMENTS FOR WEST PROPERTY LINE TO 7, AND PROVIDE
 THE REQUIRED TREES OR NUMBER OF SUBSTITUTE PALMS PER
 CURRENT CODE REQUIREMENTS (3:1).
  
 8. PLEASE SHOW THE REQUIRED HEDGE FOR THE DUMPSTER
 ENCLOSURE.
  
 9. PLEASE REMOVE THE CHART LABELED DESIGN OPTIONS, AS
 IT IS NO LONGER APPLICABLE, AND UPDATE THE FLORIDA
 FRIENDLY LANDSCAPE OPTIONS CHART.
  
 10. IF THE PARKING IS TO REMAIN IN THE PROPOSED
 LOCATION, THE TERMINAL ISLAND LANDSCAPE MUST MEET CODE
 REQUIREMENTS.
  
 11. THREE ILEX CASSINE ARE SHOWN ON THE PLAN, BUT NOT
 ON THE PLANT LIST. PLEASE REVISE.
 12. PLEASE REVISE LANDSCAPE REQUIREMENT LIST #8 LIST TO
 SHOW CURRENT 12 FOOT MINIMUM TREE SIZES REQUIRED.
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 1 Status P Date 01-09-2018 Cont ID  
Sent By   Date 01-09-2018 Time   Rev Time 1.00
Received By   Date 01-08-2018 Time   Sent To  
Notes
2018-01-09 08:34:50THE ENCLOSURE NEEDS TO HAVE PIN HOLES TO HOLD THE GATES
 OPEN WHILE SERVICEING THE CONTAINER.

Review Stop STORM STORMWATER
Rev No 2 Status F Date 05-17-2018 Cont ID  
Sent By tward Date 05-17-2018 Time 12:44 Rev Time 0.00
Received By tward Date 05-17-2018 Time 13:02 Sent To  
Notes
2018-05-17 13:02:43THE FOLLOWING COMMENTS ARE FROM THE REVIEW OF THE MAY
 13, 2018 SUBMITTAL PACKAGE. COMMENTS # 1- 10 REFER TO
 WHETHER OR NOT THE COMMENTS FROM THE INITIAL STORM
 REVIEW WERE ADDRESSED IN THIS SUBMITTAL.
  
 1. SURVEY IDENTIFIES THE PROJECT BEING WITHIN FEMA
 FLOOD ZONE 'X', WHICH IS NOT A SPECIAL FLOOD HAZARD
 AREA.
  
 2. COMMENT SATISFIED.
  
 3. VERTICAL DATUM IS LISTED AS NAVD 1988. THE CITY'S
 VERTICAL DATUM IS NGVD 1929. THE CITY WILL ALLOW THE
 USE OF NAVD 1988 PROVIDED A CONVERSION TO NGVD 19219 IS
 SHOWN ON THE PLANS AND SURVEY.
  
 4. COMMENT NOT ADDRESSED. ONLY SHEET C-1 OF SIX CIVIL
 ENGINEERING SHEETS WAS PROVIDED.
  
 5. COMMENT SATISFIED.
  
 6. ADD "MIN. 3 FEET' HORIZONTAL DIMENSION NOTES BETWEEN
 WATER MAINS AND DRAINAGE STRUCTURES / PIPES.
  
 7. NO CALCULATIONS PROVIDED. THESE CAN BE SUBMITTED
 WITH THE ENGINEERING PERMIT APPLICATION.
  
 8. PROVIDE GRADING ARROWS TO THE PLAN SHEET TO INDICATE
 SWALE DOES NOT DRAIN TO ADJACENT PROPERTY.
  
 9. PROVIDE A TYPICAL CROSS SECTION EXTENDING FROM THE
 CENTERLINE OF OKEECHOBEE TO THE BACK OF WALK SHOWING
 PROPOSED GRADE BREAKS, DIMENSIONS, SLOPES.
  
 10. NO LIMITS OR NOTES REGARDING MILLING AND OVERLAY
 PROVIDED ON THE ENGINEERING PLAN SHEET.
  
 11. THE SEWER LATERAL ON ALPHA ROAD IS TO BE REMOVED
 AND CAPPED AT THE MAIN BY THE CONTRACTOR. REVISE THE
 NOTE ON SHEET C-1 TO INDICATE THIS. ALPHA ROAD TO BE
 MILLED AND OVERLAID PER THE CITY DETAIL.
  
 TRACY WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120
 [email protected]

Review Stop STORM STORMWATER
Rev No 1 Status F Date 01-09-2018 Cont ID  
Sent By tward Date 01-09-2018 Time 14:38 Rev Time 0.00
Received By tward Date 01-09-2018 Time 14:40 Sent To  
Notes
2018-01-09 14:39:56THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT
 APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP://
 WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER
 MITS-APPLICATIONS
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
  
 1. NEW FEMA FIRM MAPS AND TWO FEET OF FREEBOARD ABOVE
 BASE FLOOD ELEVATION FOR STRUCTURES IN SPECIAL FLOOD
 HAZARD AREA ARE NOW IN EFFECT. THE MAPS ARE AVAILABLE
 AT HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX?
  
 2. UPDATE THE FLOOD INFORMATION ON THE BOUNDARY AND
 TOPOGRAPHIC SURVEY AND POSSIBLY ON THE SITE PLAN (SHEET
 A-1).
  
 3. LABEL THE VERTICAL DATUM ON THE ENGINEERING PLANS.
  
 4. USE THE CITY?S TRENCH-BACKFILL-PAVEMENT RESTORATION
 DETAIL (GC-9) IN LIEU OF THE PAVEMENT REPAIR DETAIL ON
 SHEET C-5.
  
 5. SHOW UTILITIES ON THE LANDSCAPE PLANS.
  
 6. PROVIDE MORE HORIZONTAL CLEARANCE BETWEEN THE
 PROPOSED CATCH BASINS AND FIRE LINE / WATER SERVICE
 LINE.
  
 7. STORMWATER MANAGEMENT SYSTEM TO BE DESIGNED TO MEET
 SFWMD CRITERIA INCLUDING WATER QUALITY TREATMENT AND
 PEAK DISCHARGE.
  
 8. PROVIDE A SWALE ALONG THE EAST PROPERTY LINE TO
 COLLECT THE STORMWATER RUNOFF BEFORE IT FLOWS ONTO THE
 ADJACENT PROPERTY.
  
 9. PARKING ALONG OKEECHOBEE ROAD MAY REQUIRE A ?DEEPER?
 SWALE TO COLLECT THE STORMWATER RUNOFF AND DIRECT IT TO
 THE INTERNAL CATCH BASINS BEFORE IT FLOWS INTO THE
 OKEECHOBEE ROAD R/W.
  
 10. SHOW ON THE ENGINEERING PLANS THE MILL AND
 RESURFACE LIMITS FOR THE TRENCH REPAIR IN THE RIGHT-OF
 WAY PER CITY DETAIL GC-9.
  
  
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE
 ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120
 [email protected]
  

Review Stop SURVEY SURVEYING
Rev No 2 Status P Date 05-30-2018 Cont ID  
Sent By vnoel Date 05-30-2018 Time 09:35 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
***NONE***

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 01-05-2018 Cont ID  
Sent By vnoel Date 01-05-2018 Time 08:00 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2018-01-05 08:18:231. DUMPSTER DETAIL NOT CITY STANDARD. APPROVAL OF
 DETAIL AND LOCATION WILL BE REQUIRED BY PUBLIC WORKS.
 2. NOTE #7 SAYS SURVEY IS NOT VALID FOR DESIGN?
 3. NO VERTICAL DATUM SPECIFIED ON ENG. PLANS.
 4. SURVEY SHOULD BE ABSTRACTED FOR EASEMENTS; APPEARS
 TO BE POLE LINE ALONG EAST PROPERTY LINE.
 5. SITE/CIVIL PLANS WILL NEED TO BE SUBMITTED THRU
 ENGINEERING.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 2 Status F Date   Cont ID  
Sent By   Date 05-25-2018 Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2018-05-25 17:05:22- APPLICANT'S MAY 13 LETTER STATES THAT BACK OUT
 PARKING HAS BEEN APPROVED. THE TRAFFIC DIVISION HAS NOT
 APPROVED BACK OUT PARKING INTO THE PUBLIC RIGHT OF WAY.
 - SIDEWALK ON OLD OKEECHOBEE ROAD NEEDS TO CONNECT TO
 PUBLIC RIGHT OF WAY.
  
 ERIK D. FERGUSON, PE
 CITY TRANSPORTATION ENGINEER
 561-494-1092
 [email protected]

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 01-10-2018 Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
2018-01-10 09:06:421) BACK OUT PARKING INTO THE RIGHT OF WAY IS NOT
 ALLOWED.
 2) PROPOSED SIDEWALK ALONG OKEECHOBEE IS OUTSIDE OF THE
 RIGHT OF WAY. WHO WILL MAINTAIN THE SIDEWALK? SIDEWALK
 NEEDS TO BE ACCESIBLE TO THE PUBLIC.
 3) SIDEWALK ALONG OKEECHOBEE NEEDS TO BE RUN ALONG THE
 ENTIRE FRONTAGE.
 4) TRAFFIC IMPACT STATEMENT WASN'T INCLUDED IN PACKET
 SENT TO ENGINEERING.
  
 ERIK D. FERGUSON, P.E.
 CITY TRANSPORTATION ENGINEER
 [email protected]
 561-494-1092
  

Review Stop Z ZONING
Rev No 2 Status P Date 05-18-2018 Cont ID  
Sent By   Date 05-18-2018 Time   Rev Time 0.00
Received By pgreilic Date 05-18-2018 Time 09:46 Sent To  
Notes
2018-05-18 09:47:25PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 01-09-2018 Cont ID  
Sent By   Date 01-09-2018 Time   Rev Time 0.00
Received By pgreilic Date 01-09-2018 Time 12:35 Sent To  
Notes
2018-01-09 12:37:30Z17120011
 FSPR 17-12
 1626 OKEECHOBEE ROAD
  
 1.) PARKING SPACES CANNOT ENTER AND EXIT DIRECTLY ONTO
 ADJACENT ROW. CONSIDER RELOCATING PARKING SPACES TO
 FRONT OF THE SITE (NARROWEST LOT LINE ABUTTING ROW, IN
 THIS CASE OFF OF ALPHA ROAD) WITH INGRESS/EGRESS OFF OF
 ALPHA ROAD. CONSIDER REDUCED PARKING SPACES OR ANGLED
 PARKING TO MAXIMIZE THIS PORTION OF THE SITE.
  
 2.) LABEL DISTANCE BETWEEN PRIMARY STRUCTURE AND
 ACCESSORY BUILDING
  
 3.) PLEASE INCLUDE ACCURATE AND UP TO DATE CITY
 APPROVED DETAILS FOR BIKE RACK, DUMPSTER, AND STRIPING
 FOR PARKING STALLS
  
 4.) PROVIDE SIDEWALK TO ENABLE PEDESTRIAN ACCESS
  
 -WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN
 (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG/.PDF
 FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 -PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUTE TO NOT BE SUFFIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20 PERCENT OF THE ORIGNAL APPLICATION FEE.
  
 -PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS
 FROM THE DATE OF THE PPRC MEETING, THE CASE SHALL BE
 CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL REQUIRE
 A NEW DEVELOPMENT APPLICATION.
  
  