Plan Review Details - Project Z17030019
Plan Review Stops For Project Z17030019
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 03-15-2018 Cont ID  
Sent By skennedy Date 03-15-2018 Time 11:13 Rev Time 0.00
Received By skennedy Date 03-15-2018 Time 11:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 03-05-2018 Cont ID  
Sent By rbrown Date 03-05-2018 Time 16:42 Rev Time 0.00
Received By rbrown Date 03-05-2018 Time 16:42 Sent To  
Notes
2018-03-05 17:04:00DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR PERMITTING.
  
 2. ROUTE FROM ACCESSIBLE PARKING SPACES TO BUILDING
 ENTRANCE. SHEET A-1.1, GROUND LEVEL FLOOR PLAN, SHOWS
 THAT USERS OF THE ACCESSIBLE PARKING SPACE NEXT TO THE
 LOADING SPACE/BICYCLE RACK MUST ENTER THE BUILDING VIA
 A SECONDARY (REAR) ENTRANCE BECAUSE THE EXTERIOR ROUTE
 TO THE MAIN ENTRANCE DOORS WOULD REQUIRE THEM TO
 NEGOTIOATE CURBS AND TRAVEL ALONG THE VEHICULAR DRIVE
 AISLE. CONTRARY TO THE COMMENT RESPONSE LETTER THAT WAS
 SUBMITTED, SHEET A-0.1 DOES NOT ADDRESS THAT ISSUE
 BECAUSE THERE IS NO NOTE STATING THAT THE SECONDARY
 (REAR) ENTRANCE WILL BE AVAILABLE (UNLOCKED) AT ALL
 TIMES. A NOTE ON SHEET A-0.1 AND/OR SHEET A1.1 OF THE
 PLANS IS THE BEST WAY TO CONFIRM THAT SO THAT THIS ITEM
 DOES NOT CAUSE THE BUILDING PERMIT PLAN REVIEW TO FAIL.
 PER SECTION 208.3 OF FLORIDA ACCESSIBILITY CODE,
 ACCESSIBLE PARKING SPACES ARE TO BE LOCATED ON THE
 SHORTEST POSSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING
 TO AN ACCESSIBLE ENTRANCE FOR EACH BUILDING.
  
 3. THE HEADROOM FOR THE ACCESSIBLE PARKING SPACES THAT
 IS UNDER ROOF SHALL MEET THE VAN ACCESSIBLE PARKING
 SPACE REQUIREMENT OF 98 INCHES. THE COMMENT RESPONSE
 LETTER STATES THAT ONE OF THE ACCESSIBLE PARKING SPACES
 HAS BEEN MOVED OUTSIDE. THIS IMPLIES THAT ACCESSIBILITY
 VAN WOULD BE PARKED IN THAT SPACE. THAT SOLUTION DOES
 NOT PROVIDE EQUIVALENT FACILITATION BECAUSE IT MEANS
 THAT ARE NOW TWO TYPES OF ACCESSIBLE PARKING AND THE
 MOST DESIRABLE ACCESSIBLE PARKING, WHICH IS UNDER ROOF,
 IS NOT AVAILALBE TO ACCESSIBILITY VAN USERS. THE
 ACCESSIBLE PARKING SPACE THAT IS UNDER ROOF MUST BE
 DESIGNED TO MEET THE VAN ACCESSIBLE PARKING SPACE
 REQUIREMENT OF 98 INCHES HEADROOM. PER SECTION 208.2.4
 OF FLORIDA ACCESSIBILITY CODE, ONE IN EVERY SIX
 ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING
 STRUCTURE, SHALL BE VAN ACCESSIBLE AND DESIGNED IN
 ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY
 CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT
 SPACE AND VEHICULAR ACCESS ROUTE).
  
 4. INFORMATIONAL: SEPARATE PERMITS REQUIRED. ALL
 APPLICABLE PERMITS AND SUB-PERMITS MUST BE OBTAINED
 BEFORE COMMENCING THE WORK. SEPARATE PERMITS, PLANS AND
 FEES, ARE REQUIRED FOR SIGNS, GAS SYSTEMS, GENERATORS,
 FIRE ALARM SYSTEMS, FIRE SPRINKLER AND OTHER FIRE
 SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, SITE
 LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC.
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 04-11-2017 Cont ID  
Sent By rbrown Date 04-11-2017 Time 20:07 Rev Time 0.00
Received By rbrown Date 04-11-2017 Time 16:41 Sent To  
Notes
2017-04-11 20:29:10DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR PERMITTING.
  
 2. ROUTE FROM ACCESSIBLE PARKING SPACES TO BUILDING
 ENTRANCE. SHEET A-1.1, GROUND LEVEL FLOOR PLAN, SHOWS
 THAT USERS OF THE ACCESSIBLE PARKING SPACES MUST ENTER
 THE BUILDING FROM A SECONDARY ENTRANCE BECAUSE THE
 EXTERIOR ROUTE TO THE MAIN ENTRANCE DOORS WOULD REQUIRE
 THEM TO NEGOTIOATE CURBS OR TRAVEL ALONG THE VEHICULAR
 DRIVE AISLE. CONFIRM THAT ACCESS TO THE BUILDING VIA
 THE ALTERNATIVE BUILDING ENTRANCE WILL BE AVAILABLE AT
 ALL TIMES. PER SECTION 208.3 OF FLORIDA ACCESSIBILITY
 CODE, ACCESSIBLE PARKING SPACES ARE TO BE LOCATED ON
 THE SHORTEST POSSIBLE ROUTE OF TRAVEL FROM ADJACENT
 PARKING TO AN ACCESSIBLE ENTRANCE FOR EACH BUILDING.
  
 3. EXIT ROUTE FROM THE STAIR TOWERS TO THE STREET.
 BUILDING OCCUPANTS EXITING VIA THE STAIRS IN AN
 EMERGENCY WILL BE REQUIRED TO TO NEGOTIOATE CURBS AND
 TRAVEL ALONG THE VEHICULAR DRIVE AISLE TO GET TO THE
 AWAY FROM THE BUILDING. OPTIONS FOR IMPROVING THE
 EXTERIOR ROUTE TO THE STREET SHOULD BE CONSIDERED.
  
 4. THE HEADROOM FOR AT LEAST ONE OF THE ACCESSIBLE
 PARKING SPACES SHALL MEET THE VAN ACCESSIBLE PARKING
 SPACE REQUIREMENT OF 98 INCHES. PER SECTION 208.2.4 OF
 FLORIDA ACCESSIBILITY CODE, ONE IN EVERY SIX ACCESSIBLE
 SPACES (AT LEAST ONE) IN A PARKING STRUCTURE, SHALL BE
 ?VAN ACCESSIBLE? AND DESIGNED IN ACCORDANCE WITH
 SECTION OF 502 OF FLORIDA ACCESSIBILITY CODE (VERTICAL
 CLEARANCE NOT LESS THAN 98 INCHES AT SPACE AND
 VEHICULAR ACCESS ROUTE).
  
 5. BUILDING SIZE. WHEN SUBMITTED FOR BUILDING PERMIT,
 THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR
 THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT,
 AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE
 FLORIDA BUILDING CODE
  
 6. BUILDING LOCATION RELATIVE TO THE PROPERTY LINE AND
 OTHER STRUCTURES. WHEN SUBMITTED FOR BUILDING PERMIT,
 COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF
 OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 7. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS,
 FIRE SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS,
 GREASE INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE,
 SITE IRRIGATION, ETC.
  
 8. THIS PROJECT WILL BE SUBJECT TO ART IN PUBLIC PLACES
 (AIPP) ASSESSMENT. FOR ADVICE ON THE PROVISION OF
 PUBLIC ARTWORK IN LIEU OF THE AIPP ASSESSMENT, CONTACT
 SYBILLE WELTER, ART IN PUBLIC PLACES COORDINATOR, AT
 (561) 822-1521, OR BY EMAIL: [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 3 Status P Date 02-06-2018 Cont ID  
Sent By squinone Date 02-06-2018 Time   Rev Time 0.00
Received By squinone Date 02-06-2018 Time   Sent To  
Notes
2018-02-06 17:26:02AFTER THE SITE PLAN IS APPROVED, IN THE NEXT PHASE, THE
 FOLLOWING GENERAL COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL:
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED FROM THE FOLLOWING WEBSITE LINK: HTTP
 ://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-
 PERMITS-APPLICATIONS
  
 2. PLEASE SUBMIT THE LATEST VERSION OF THE ?AUTO-CALC
 CERTIFIED COST ESTIMATE FORM? FOR SUBMISSION TO CITY OF
 WEST PALM BEACH PUBLIC WORKS DEPARTMENT FOR ADDITIONAL
 WORK PROPOSED. THIS FORM CAN BE DOWNLOADED FROM THE
 FOLLOWING LINK: HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-
 PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS
  
 3. SUBMIT WITH THE ENGINEERING DEVELOPMENT APPROVAL
 APPLICATION SIGNED & SEALED ENGINEER/MEP WATER AND
 SANITARY SEWER CALCULATION (IN DETAIL I.E. AVERAGE AND
 PEAK WITH PEAKING FACTOR). SUBMIT CALCULATIONS TO
 VALIDATE METER SIZE SELECTION. SHOW THESE CALCULATIONS
 ON THE UTILITY PLAN SHEET AS WELL;
  
 4. SUBMIT ESTIMATES FOR WATER AND FIRE DEMAND, BOTH
 AVERAGE AND PEAK FLOW WITH PEAKING FACTOR. ALSO SUBMIT
 ESTIMATES OF SANITARY SEWER FLOW FOR THE PROPOSED
 DEVELOPMENT. SHOW PROJECTED DEMANDS ON THE UTILITY PLAN
 SHEET;
  
 5. CCTV MUST BE PROVIDED FROM MANHOLE TO MANHOLE WHERE
 THE PROPOSED SANITARY SEWER WILL BE LOCATED. CONTACT ME
 FOR THE MANHOLE NUMBER AND SUBMIT CD WITH THE
 ENGINEERING DEVELOPMENT APPROVAL APPLICATION;
  
 6. SHOW THE NEAREST FIRE HYDRANT TO THIS SITE ON THE
 FINAL UTILITY PLAN. FIRE HYDRANT FLOW TEST DATA FROM
 EXISTING FIRE HYDRANT WILL BE REQUIRED PART OF THE PLAN
 SUBMITTAL. SHOW THE HYDRANT FLOW TEST RESULT IN THE
 PLANS;
  
 7. FIRE HYDRANT TEST CAN BE REQUESTED AT (561)804-4700.
  
 8. PLEASE INCLUDE THE LATEST VERSION OF THE APPLICABLE
 CITY OF WEST PALM BEACH STANDARD UTILITY DETAILS TO THE
 DETAIL SHEET/S DURING SUBMISSION OF THE FINAL
 ENGINEERING PLANS. CONTACT THE ENGINEERING SERVICES
 DEPARTMENT FOR THE LATEST REVISED DETAILS IN CAD
 FORMAT. CITY?S STANDARD DETAILS (IN PDF FILE FORMAT)
 CAN BE DOWNLOADED FROM THE FOLLOWING SITE: HTTP://WPB.O
 RG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PERMITS-
 APPLICATIONS
  
 9. PLACEMENT OF THE ANY PROPOSED METER, BACKFLOW
 PREVENTER, DCDA ETC. SHALL BE INSTALLED PER THE CITY?S
 STANDARD DETAILS. WATER METER SHOULD BE WITHIN THE
 RIGHT-OF-WAY OR INSIDE AN 'UTILITY EASEMENT' JUST
 INSIDE THE PROPERTY NEAR THE RIGHT-OF-WAY AND
 ACCESSIBLE;
  
 10. IN THE FINAL PLANS, SHOW CONFLICT INFORMATION
 (BOTTOM AND TOP OF CROSSING PIPES) AT THE CONFLICT
 POINTS OF ALL WATER, STORM AND SANITARY SEWER PIPES AS
 WELL AS OTHER FRANCHISE UTILITIES. SOFT DIGS WILL BE
 REQUIRED AT THE PROPOSED AND EXISTING UTILITY
 CROSSINGS;
  
 11. IN THE FINAL PLANS, SHOW DIRECTION OF FLOW FOR THE
 EXISTING SANITARY SEWER. SHOW INVERT AT CONNECTION
 POINTS AND INCLUDE A PROFILE FOR THE PROPOSED SERVICE
 LATERAL WITH GROUND ELEVATIONS ABOVE THE PIPE;
  
 12. PAVEMENT RESTORATION FOR OPEN CUT/TRENCH FOR
 UTILITY CONNECTION WORKS WILL NEED TO BE IN ACCORDANCE
 WITH CITY STANDARD DETAIL GC-9. THE ROAD SHALL BE
 MILLED/RESURFACED FOR FULL LANE WIDTH OF THE TRAVEL
 LANE(S) ENCROACHED BY THE TRENCH AREA, INCLUDING A
 TRANSITION AREA OF 50 FEET ON EACH SIDE OF THE TRENCH.
 PLEASE SHOW ON THE FINAL PLANS THE EXTENT OF THE
 MILLING/RESURFACING AND THE REPLACEMENT OF
 THERMOPLASTIC STRIPING;
  
 13. SHOW ON THE FINAL PLANS SIZE AND MATERIAL OF ALL
 EXISTING UTILITIES ON POINSETTIA AVENUE AND 27TH STREET
 INCLUDING BUT NOT LIMITED TO WATER, SEWER, GAS,
 UNDERGROUND ELECTRIC CONDUITS ETC. PLEASE IDENTIFY THE
 SOURCE OF THE AS-BUILT INFORMATION UTILIZED FOR THE
 POTABLE WATER, SANITARY SEWER, AND STORM SEWER DESIGN;
  
 14. FOR THE FINAL WATER AND SEWER PLANS, INCLUDE A NOTE
 THAT: AS OF DECEMBER 20, 2015 THE CITY OF WEST PALM
 BEACH CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED,
 MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD
 FREE." FOR MORE INFORMATION REFER TO THE LINK BELOW: HT
 TP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLICA
 TIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL
  
 15. ALL PROPOSED FIRE DEPARTMENT CONNECTIONS SHALL BE
 WITHIN 100 FEET OF A FIRE HYDRANT AND SHALL BE WITHIN
 AN EASEMENT WITHIN THE PROPERTY.
  
 SOFIA QUINONES-BENEJAM, EI
 PROJECT ENGINEER
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33402
 (MAILING ADDRESS: PO BOX 3366)
 P: 561.494.1108
 C: 561.459.6518
 F: 561.494.1116
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 2 Status F Date 08-28-2017 Cont ID  
Sent By squinone Date 08-28-2017 Time   Rev Time 0.00
Received By squinone Date 08-25-2017 Time   Sent To  
Notes
2017-08-28 07:55:07CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT
 DATE: 08/31/2017
 PROJECT: Z17030019, DR. ALICE MOORE APARTMENTS
 ADDRESS: 335 27TH ST.
 STATUS: FAILED
  
 THIS IS AN INITIAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS, AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES.
 NO CIVIL ENGINEERING PLANS WERE SUBMITTED IN THE
 INITIAL SITE PLAN PACKAGE INDICATING STORMWATER CONTROL
 AND PLANS FOR WATER AND SEWER SERVICES/CONNECTIONS FOR
 THE PROPOSED DEVELOPMENT. FOLLOWING COMMENTS NEED TO BE
 ADDRESSED PRIOR TO SITE PLAN APPROVAL:
  
 1. A TRAFFIC IMPACT STATEMENT WILL BE REQUIRED TO
 DEMONSTRATE THAT THE PROPOSED DEVELOPMENT WOULD NOT
 IMPACT THE TRAFFIC PATTERN IN THE VICINITY OF THE
 DEVELOPMENT ADVERSELY. PLEASE CONTACT UYEN DANG, CITY'S
 TRANSPORTATION ENGINEER AT (561) 494-1087;
  
 2. SURVEY AND SITE PLAN HAVE LOT DIMENSIONS THAT ARE
 NOT CONSISTENT. PLEASE REVISE SITE PLAN TO CORRECT
 DISCREPANCIES DURING NEXT REVIEW/RE-SUBMITTAL. PARKING
 SHOWN ON THE 27TH ST. CANNOT BE PRIVATE. ONLY PUBLIC
 PARKING WITH METER WILL BE ALLOWED ON CITY?S
 RIGHT-OF-WAY. PLEASE CONTACT UYEN DANG, CITY'S
 TRANSPORTATION ENGINEER AT (561) 494-1087 FOR APPROVAL;
  
 3. PLEASE SHOW ON THE PLANS, IN THE NEXT REVIEW LEVEL,
 HOW WILL THE SITE/BUILDING BE SERVED FOR WATER, SEWER
 AND FIRE PROTECTION. SHOW ALL EXISTING UTILITIES WITHIN
 THE VICINITY OF THE PROPOSED SITE AS WELL AS PROPOSED
 UTILITIES TO SERVE THE DEVELOPMENT (LABEL SIZE AND
 MATERIAL OF ALL PIPES AND CONDUITS ETC.);
  
 4. EXISTING SERVICES SERVING THIS SITE THAT WILL NOT BE
 USED ARE TO BE DEACTIVATED. PLUG THE EXISTING SERVICES
 AT THE MAIN - ABANDONED SERVICE LINES THAT ARE 2" AND
 SMALLER CAN BE ABANDONED IN PLACE, BUT ABANDONED
 SERVICE LINES LARGER THAN 2" ARE TO BE REMOVED;
  
 5. SHOW THE EXISTING WATER LINE RUNNING ALONG THE NORTH
 SIDE OF THE PROPERTY. IT IS AN ASBESTOS 4-INCH DIAMETER
 A/C LINE THAT THE CITY WOULD LIKE FOR YOU TO ABANDON AS
 PART OF THE PROJECT. SPECIALTY CONTRACTOR WILL BE
 REQUIRED.
  
 6. MOVE THE PROPOSED MH NO. 2 CLOSER TO THE
 RIGHT-OF-WAY IF POSSIBLE. CALL OUT THE SIZE AND SLOPE
 OF PROPOSED SEWER MAIN. CCTV INFORMATION UPON
 COMPLETION WILL BE REQUIRED.
  
 7. SUBMIT ESTIMATES FOR WATER AND FIRE DEMAND, BOTH
 AVERAGE AND PEAK FLOW WITH PEAKING FACTOR AND REQUIRED
 TO SHOW THE PROPOSED GPD ON THE PLANS. ALSO SUBMIT
 ESTIMATES OF SANITARY SEWER FLOW FOR THE PROPOSED
 DEVELOPMENT AND SHOW PROPOSED DEMANDS ON THE PLANS;
  
 8. THE AVAILABLE WATER PRESSURE IN THIS PORTION OF THE
 CITY MAY NOT BE ACCEPTABLE AT ELEVATIONS HIGHER THAN
 THE 2ND FLOOR. WE RECOMMEND A LONG-TERM PRESSURE STUDY
 BE PERFORMED PRIOR TO FINALIZATION OF THE UTILITY
 DESIGN;
  
 9. ON THE LANDSCAPING PLAN, WHEN SUBMITTED IN THE NEXT
 REVIEW PHASE, SHOW LOCATIONS OF ALL WATER METERS,
 VALVES, CLEAN-OUTS, LIGHT POLES, ETC. ROOT BARRIERS MAY
 BE REQUIRED WHERE PLANTINGS ARE NEAR UNDERGROUND
 STORMWATER, SANITARY, OR POTABLE WATER LINES. ALSO
 CLEARLY INDICATE ALL EXISTING AND PROPOSED EASEMENTS ON
 THE LANDSCAPE PLAN;
  
 10. A MAINTENANCE AGREEMENT WILL BE REQUIRED FOR THE
 NON-STANDARD ELEMENTS (TREES AND TREE GRATES; PAVERS,
 ETC.) PROPOSED WITHIN POINSETTIA AVENUE AND 27TH STREET
 RIGHT-OF-WAYS;
  
 11. SHOW ON THE SITE PLANS ADA ACCESSIBLE RAMPS ON THE
 SIDEWALK AT EACH ENTRANCE AND EXIT /DRIVEWAY APPROACH;
  
 12. PLEASE SUBMIT ESTIMATES FOR THE SOLID WASTE
 COLLECTION YARDAGE AT THE CONCEPTUAL STAGE. AS PART OF
 THE FINAL DESIGN, THIS SOLID WASTE ESTIMATE WILL NEED
 TO BE VERIFIED TO VALIDATE APPROPRIATE NUMBER AND SIZE
 OF DUMPSTERS/GARBAGE RECEPTACLES. PLEASE SHOW ON THE
 PLAN IF A COMPACTOR IS PROPOSED TO REDUCE THE YARDAGE
 OF WASTE THAT WILL NEED TO BE COLLECTED;
  
 13. THE TRASH DUMPSTER/COMPACTORS MUST LOCATED IN AREAS
 EASILY SERVICED BY THE CITY SANITATION EQUIPMENT AND
 MANPOWER PER SECTION 74-35(A)(5) OF THE CODE OF
 ORDINANCES. A 'TRASH ROOM' IS SHOWN ON THE SUBMITTED
 SITE PLAN WHICH IS INSIDE THE BUILDING ENCLOSURE;
  
 14. IF ROLL OUT TYPE DUMPSTER IS PROPOSED, PLEASE NOTE
 ON THE PLANS THAT: 'OWNER IS RESPONSIBLE TO ROLL OUT
 THE DUMPSTER OUTSIDE THE ENCLOSURE TO THE OPEN SPACE
 PRIOR TO CITY'S SANITATION CREW PICK UP GARBAGE'.
 CITY'S FRONT LOADING SANITATION/GARBAGE TRUCKS NEED AT
 LEAST 25-FEET VERTICAL CLEARANCE FOR TIPPING THE
 GARBAGE RECEPTACLES/BINS OVER IT;
  
 15. FOR SANITATION/GARBAGE COLLECTION CONTACT THE
 CITY'S PUBLIC WORKS DEPARTMENT. FINAL APPROVED SITE
 PLANS NEED TO SHOW PROPOSED SANITATION COLLECTION PLANS
 AND DETAILS; AND WILL NEED APPROVAL FROM PETER BIENIEK,
 PUBLIC WORKS DIRECTOR. IF A SEPARATE ON-SITE LOCATION
 IS CHOSEN FOR STANDARD DUMPSTER, PLEASE INCLUDE THE
 CITY OF WEST PALM BEACH STANDARD DETAIL FOR THE
 DUMPSTER ENCLOSURE ON THE PLANS. MINIMUM DIMENSIONAL
 (E.G. THE GATE WIDTH MUST BE A MINIMUM OF 12.5 FEET)
 REQUIREMENTS FOR THE ENCLOSURE ARE LISTED IN CODE OF
 ORDINANCES, SECTION 94-444(B) OF THE CODE OF
 ORDINANCES. CITY STANDARD DETAIL GC-8 MAY BE DOWNLOADED
 AT: HTTP://WPB.ORG/ENGINEERING/ENGINEERING-SERVICES/ENG
 INEERING-STANDARDS/
  
 16. PLEASE PROVIDE AN AUTOTURN ANALYSIS DEMONSTRATING
 THE SOLID WASTE COLLECTION VEHICLE CAN ACCESS AND
 MANEUVER WITHIN THE PROPOSED DEVELOPMENT.
  
 AFTER THE SITE PLAN IS APPROVED, IN THE NEXT PHASE, THE
 FOLLOWING GENERAL COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL:
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED FROM THE FOLLOWING WEBSITE LINK:
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 2. PLEASE SUBMIT THE LATEST VERSION OF THE 'AUTO-CALC
 CERTIFIED COST ESTIMATE FORM' FOR SUBMISSION TO CITY OF
 WEST PALM BEACH PUBLIC WORKS DEPARTMENT FOR ADDITIONAL
 WORK PROPOSED. THIS FORM CAN BE DOWNLOADED FROM THE
 FOLLOWING LINK: HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-
 PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS
  
 3. SUBMIT WITH THE ENGINEERING DEVELOPMENT APPROVAL
 APPLICATION SIGNED & SEALED ENGINEER/MEP WATER AND
 SANITARY SEWER CALCULATION (IN DETAIL I.E. AVERAGE AND
 PEAK WITH PEAKING FACTOR). SUBMIT CALCULATIONS TO
 VALIDATE METER SIZE SELECTION. SHOW THESE CALCULATIONS
 ON THE UTILITY PLAN SHEET AS WELL;
  
 4. DEMONSTRATE THAT THE PROPOSED 2 INCHES WATER SERVICE
 CAN PROVIDE THE REQUIRE FLOWS TO THE DUAL WATER SERVICE
 ? 2 INCHES AND 1-1/2 INCHES. NOTE, 1-1/2 INCHES IS NOT
 A STANDARD SIZE FOR WATER SERVICE.
  
 5. CHANGE MATERIAL FOR 2 INCHES DIP, 8 INCHES X 2
 INCHES TEE IS NOT USED.
  
 6. SHOW THE NEAREST FIRE HYDRANT TO THIS SITE ON THE
 FINAL UTILITY PLAN. FIRE HYDRANT FLOW TEST DATA FROM
 EXISTING FIRE HYDRANT WILL BE REQUIRED PART OF THE PLAN
 SUBMITTAL. SHOW THE HYDRANT FLOW TEST RESULT IN THE
 PLANS;
  
 7. FIRE HYDRANT TEST CAN BE REQUESTED AT (561)804-4700.
  
 8. PLEASE INCLUDE THE LATEST VERSION OF THE APPLICABLE
 CITY OF WEST PALM BEACH STANDARD UTILITY DETAILS TO THE
 DETAIL SHEET/S DURING SUBMISSION OF THE FINAL
 ENGINEERING PLANS. CONTACT THE ENGINEERING SERVICES
 DEPARTMENT FOR THE LATEST REVISED DETAILS IN CAD
 FORMAT. CITY'S STANDARD DETAILS (IN PDF FILE FORMAT)
 CAN BE DOWNLOADED FROM THE FOLLOWING SITE: HTTP://WPB.O
 RG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PERMITS-
 APPLICATIONS
  
 9. PLACEMENT OF THE ANY PROPOSED METER, BACKFLOW
 PREVENTER, DCDA ETC. SHALL BE INSTALLED PER THE CITY?S
 STANDARD DETAILS. WATER METER SHOULD BE WITHIN THE
 RIGHT-OF-WAY OR INSIDE AN 'UTILITY EASEMENT' JUST
 INSIDE THE PROPERTY NEAR THE RIGHT-OF-WAY AND
 ACCESSIBLE;
  
 10. IN THE FINAL PLANS, SHOW CONFLICT INFORMATION
 (BOTTOM AND TOP OF CROSSING PIPES) AT THE CONFLICT
 POINTS OF ALL WATER, STORM AND SANITARY SEWER PIPES AS
 WELL AS OTHER FRANCHISE UTILITIES. SOFT DIGS WILL BE
 REQUIRED AT THE PROPOSED AND EXISTING UTILITY
 CROSSINGS;
  
 11. IN THE FINAL PLANS, SHOW DIRECTION OF FLOW FOR THE
 EXISTING SANITARY SEWER. SHOW INVERT AT CONNECTION
 POINTS AND INCLUDE A PROFILE FOR THE PROPOSED SERVICE
 LATERAL WITH GROUND ELEVATIONS ABOVE THE PIPE;
  
 12. PAVEMENT RESTORATION FOR OPEN CUT/TRENCH FOR
 UTILITY CONNECTION WORKS WILL NEED TO BE IN ACCORDANCE
 WITH CITY STANDARD DETAIL GC-9. THE ROAD SHALL BE
 MILLED/RESURFACED FOR FULL LANE WIDTH OF THE TRAVEL
 LANE(S) ENCROACHED BY THE TRENCH AREA, INCLUDING A
 TRANSITION AREA OF 50 FEET ON EACH SIDE OF THE TRENCH.
 PLEASE SHOW ON THE FINAL PLANS THE EXTENT OF THE
 MILLING/RESURFACING AND THE REPLACEMENT OF
 THERMOPLASTIC STRIPING;
  
 13. SHOW ON THE FINAL PLANS SIZE AND MATERIAL OF ALL
 EXISTING UTILITIES ON POINSETTIA AVENUE AND 27TH STREET
 INCLUDING BUT NOT LIMITED TO WATER, SEWER, GAS,
 UNDERGROUND ELECTRIC CONDUITS ETC. PLEASE IDENTIFY THE
 SOURCE OF THE AS-BUILT INFORMATION UTILIZED FOR THE
 POTABLE WATER, SANITARY SEWER, AND STORM SEWER DESIGN;
  
 14. FOR THE FINAL WATER AND SEWER PLANS, INCLUDE A NOTE
 THAT: AS OF DECEMBER 20, 2015 THE CITY OF WEST PALM
 BEACH CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED,
 MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD
 FREE." FOR MORE INFORMATION REFER TO THE LINK BELOW: HT
 TP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLICA
 TIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL
  
 15. ALL PROPOSED FIRE DEPARTMENT CONNECTIONS SHALL BE
 WITHIN 100 FEET OF A FIRE HYDRANT AND SHALL BE WITHIN
 AN EASEMENT WITHIN THE PROPERTY.
  
 SOFIA QUINONES-BENEJAM, EI
 PROJECT ENGINEER
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33402
 (MAILING ADDRESS: PO BOX 3366)
 P: 561.494.1108
 C: 561.459.6518
 F: 561.494.1116
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 04-07-2017 Cont ID  
Sent By mkhan Date 04-07-2017 Time 14:07 Rev Time 0.00
Received By mkhan Date 04-07-2017 Time 14:07 Sent To  
Notes
2017-04-07 14:11:59CITY OF WEST PALM BEACH
 ENGINEERING SERVICES DEPARTMENT
  
 DATE: 04/10/2017
  
 Z17030019: 335 27TH ST. - DR. ALICE MOORE APARTMENTS
 (ISPR NO. 17-01)
  
 THIS IS AN INITIAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS, AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES.
  
 NO CIVIL ENGINEERING PLANS WERE SUBMITTED IN THE
 INITIAL SITE PLAN PACKAGE INDICATING STORMWATER CONTROL
 AND PLANS FOR WATER AND SEWER SERVICES/CONNECTIONS FOR
 THE PROPOSED DEVELOPMENT. FOLLOWING COMMENTS NEED TO BE
 ADDRESSED PRIOR TO SITE PLAN APPROVAL:
  
 1. A TRAFFIC IMPACT STATEMENT WILL BE REQUIRED TO
 DEMONSTRATE THAT THE PROPOSED DEVELOPMENT WOULD NOT
 IMPACT THE TRAFFIC PATTERN IN THE VICINITY OF THE
 DEVELOPMENT ADVERSELY. PLEASE CONTACT UYEN DANG, CITY'S
 TRANSPORTATION ENGINEER AT (561) 494-1087;
  
 2. SURVEY AND SITE PLAN HAVE LOT DIMENSIONS THAT ARE
 NOT CONSISTENT. PLEASE REVISE SITE PLAN TO CORRECT
 DISCREPANCIES DURING NEXT REVIEW/RE-SUBMITTAL. PARKING
 SHOWN ON THE 27TH ST. CANNOT BE PRIVATE. ONLY PUBLIC
 PARKING WITH METER WILL BE ALLOWED ON CITY'S
 RIGHT-OF-WAY. PLEASE CONTACT UYEN DANG, CITY'S
 TRANSPORTATION ENGINEER AT (561) 494-1087 FOR APPROVAL;
  
 3. PLEASE SHOW ON THE PLANS, IN THE NEXT REVIEW LEVEL,
 HOW WILL THE SITE/BUILDING BE SERVED FOR WATER, SEWER
 AND FIRE PROTECTION. SHOW ALL EXISTING UTILITIES WITHIN
 THE VICINITY OF THE PROPOSED SITE AS WELL AS PROPOSED
 UTILITIES TO SERVE THE DEVELOPMENT (LABEL SIZE AND
 MATERIAL OF ALL PIPES AND CONDUITS ETC.);
  
 4. SUBMIT ESTIMATES FOR WATER AND FIRE DEMAND, BOTH
 AVERAGE AND PEAK FLOW WITH PEAKING FACTOR. ALSO SUBMIT
 ESTIMATES OF SANITARY SEWER FLOW FOR THE PROPOSED
 DEVELOPMENT;
  
 5. THE AVAILABLE WATER PRESSURE IN THIS PORTION OF THE
 CITY MAY NOT BE ACCEPTABLE AT ELEVATIONS HIGHER THAN
 THE 2ND FLOOR. WE RECOMMEND A LONG-TERM PRESSURE STUDY
 BE PERFORMED PRIOR TO FINALIZATION OF THE UTILITY
 DESIGN;
  
 6. ON THE LANDSCAPING PLAN, WHEN SUBMITTED IN THE NEXT
 REVIEW PHASE, SHOW LOCATIONS OF ALL WATER METERS,
 VALVES, CLEAN-OUTS, LIGHT POLES, ETC. ROOT BARRIERS MAY
 BE REQUIRED WHERE PLANTINGS ARE NEAR UNDERGROUND
 STORMWATER, SANITARY, OR POTABLE WATER LINES. ALSO
 CLEARLY INDICATE ALL EXISTING AND PROPOSED EASEMENTS ON
 THE LANDSCAPE PLAN;
  
 7. PLEASE ALSO SHOW ON THE LANDSCAPE PLAN, WHEN
 SUBMITTED IN THE NEXT REVIEW PHASE, SHOW THE SIGHT
 TRIANGLES FOR THE ALL VEHICULAR EXITS FROM THE SITE.
 (SECTION 94-305E, CODE OF ORDINANCES);
  
 8. A MAINTENANCE AGREEMENT WILL BE REQUIRED FOR THE
 NON-STANDARD ELEMENTS (TREES AND TREE GRATES; PAVERS,
 ETC.) PROPOSED WITHIN POINSETTIA AVENUE AND 27TH STREET
 RIGHT-OF-WAYS;
  
 9. SHOW ON THE SITE PLANS ADA ACCESSIBLE RAMPS ON THE
 SIDEWALK AT EACH ENTRANCE AND EXIT /DRIVEWAY APPROACH;
  
 10. PLEASE SUBMIT ESTIMATES FOR THE SOLID WASTE
 COLLECTION YARDAGE AT THE CONCEPTUAL STAGE. AS PART OF
 THE FINAL DESIGN, THIS SOLID WASTE ESTIMATE WILL NEED
 TO BE VERIFIED TO VALIDATE APPROPRIATE NUMBER AND SIZE
 OF DUMPSTERS/GARBAGE RECEPTACLES. PLEASE SHOW ON THE
 PLAN IF A COMPACTOR IS
 PROPOSED TO REDUCE THE YARDAGE OF WASTE THAT WILL NEED
 TO BE COLLECTED;
  
 11. THE TRASH DUMPSTER/COMPACTORS MUST LOCATED IN AREAS
 EASILY SERVICED BY THE CITY SANITATION EQUIPMENT AND
 MANPOWER PER SECTION 74-35(A)(5) OF THE CODE OF
 ORDINANCES. A 'TRASH ROOM' IS SHOWN ON THE SUBMITTED
 SITE PLAN WHICH IS INSIDE THE BUILDING ENCLOSURE;
  
 12. IF ROLL OUT TYPE DUMPSTER IS PROPOSED, PLEASE NOTE
 ON THE PLANS THAT: "OWNER IS RESPONSIBLE TO ROLL OUT
 THE DUMPSTER OUTSIDE THE ENCLOSURE TO THE OPEN SPACE
 PRIOR TO CITY'S SANITATION CREW PICK UP GARBAGE".
 CITY'S FRONT LOADING SANITATION/GARBAGE TRUCKS NEED AT
 LEAST 25-FEET VERTICAL CLEARANCE FOR TIPPING THE
 GARBAGE RECEPTACLES/BINS OVER IT;
  
 13. FOR SANITATION/GARBAGE COLLECTION CONTACT THE
 CITY'S PUBLIC WORKS DEPARTMENT. FINAL APPROVED SITE
 PLANS NEED TO SHOW PROPOSED SANITATION COLLECTION PLANS
 AND DETAILS; AND WILL NEED APPROVAL FROM PETER BIENIEK,
 PUBLIC WORKS DIRECTOR. IF A SEPARATE ON-SITE LOCATION
 IS CHOSEN FOR STANDARD DUMPSTER, PLEASE INCLUDE THE
 CITY OF WEST PALM BEACH STANDARD DETAIL FOR THE
 DUMPSTER ENCLOSURE ON THE PLANS. MINIMUM DIMENSIONAL
 (E.G. THE GATE WIDTH MUST BE A MINIMUM OF 12.5 FEET)
 REQUIREMENTS FOR THE ENCLOSURE ARE LISTED IN CODE OF
 ORDINANCES, SECTION 94-444(B) OF THE CODE OF
 ORDINANCES. CITY STANDARD DETAIL GC-8 MAY BE DOWNLOADED
 AT:
  
 HTTP://WPB.ORG/ENGINEERING/ENGINEERING-SERVICES/ENGINEE
 RING-STANDARDS/
  
 14. PLEASE PROVIDE AN AUTOTURN ANALYSIS DEMONSTRATING
 THE SOLID WASTE COLLECTION VEHICLE CAN ACCESS AND
 MANEUVER WITHIN THE PROPOSED DEVELOPMENT.
 AFTER THE SITE PLAN IS APPROVED, IN THE NEXT PHASE, THE
 FOLLOWING GENERAL COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL:
  
 15. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION
 WILL BE REQUIRED FROM THE ENGINEERING SERVICES
 DEPARTMENT. THE ENGINEERING DEVELOPMENT APPROVAL
 APPLICATION FORMS CAN BE DOWNLOADED FROM THE FOLLOWING
 WEBSITE LINK:
  
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 16. PLEASE SUBMIT THE LATEST VERSION OF THE 'AUTO-CALC
 CERTIFIED COST ESTIMATE FORM' FOR SUBMISSION TO CITY OF
 WEST PALM BEACH PUBLIC WORKS DEPARTMENT FOR ADDITIONAL
 WORK PROPOSED. THIS FORM CAN BE DOWNLOADED FROM THE
 FOLLOWING LINK:
  
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 17. SUBMIT WITH THE ENGINEERING DEVELOPMENT APPROVAL
 APPLICATION SIGNED & SEALED ENGINEER/MEP WATER AND
 SANITARY SEWER CALCULATION (IN DETAIL I.E. AVERAGE AND
 PEAK WITH PEAKING FACTOR). SUBMIT CALCULATIONS TO
 VALIDATE METER SIZE SELECTION. SHOW THESE CALCULATIONS
 ON THE UTILITY PLAN SHEET AS WELL;
  
 18. SHOW ON THE FINAL PLANS WHERE ARE THE PROPOSED
 WATER AND SANITARY SEWER LINES ARE CONNECTED TO
 EXISTING WATER AND SEWER MAINS ON THE PRESIDENTIAL WAY;
  
 19. SHOW THE NEAREST FIRE HYDRANT TO THIS SITE ON THE
 FINAL UTILITY PLAN. FIRE HYDRANT FLOW TEST DATA FROM
 EXISTING FIRE HYDRANT WILL BE REQUIRED PART OF THE PLAN
 SUBMITTAL;
  
 20. PLEASE INCLUDE THE LATEST VERSION OF THE APPLICABLE
 CITY OF WEST PALM BEACH STANDARD UTILITY DETAILS TO THE
 DETAIL SHEET/S DURING SUBMISSION OF THE FINAL
 ENGINEERING PLANS. CONTACT THE ENGINEERING SERVICES
 DEPARTMENT FOR THE LATEST REVISED DETAILS IN CAD
 FORMAT. CITY'S STANDARD DETAILS (IN PDF FILE FORMAT)
 CAN BE DOWNLOADED FROM THE FOLLOWING SITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 21. PLACEMENT OF THE ANY PROPOSED METER, BACKFLOW
 PREVENTER, DCDA ETC. SHALL BE INSTALLED PER THE CITY'S
 STANDARD DETAILS. WATER METER SHOULD BE WITHIN THE
 RIGHT-OF-WAY OR INSIDE AN 'UTILITY EASEMENT' JUST
 INSIDE THE PROPERTY NEAR THE RIGHT-OF-WAY AND
 ACCESSIBLE;
  
 22. IN THE FINAL PLANS, SHOW CONFLICT INFORMATION
 (BOTTOM AND TOP OF CROSSING PIPES) AT THE CONFLICT
 POINTS OF ALL WATER, STORM AND SANITARY SEWER PIPES AS
 WELL AS OTHER FRANCHISE UTILITIES. EXISTING UTILITIES
 WITHIN THE PROPOSED SANITARY SEWER LATERAL ARE TO BE
 VERIFIED VIA SOFTDIGS AND PROVIDE ALL UTILITY CROSSING
 INFORMATION;
  
 23. IN THE FINAL PLANS, SHOW DIRECTION OF FLOW FOR THE
 EXISTING SANITARY SEWER. SHOW INVERT AT CONNECTION
 POINTS AND INCLUDE A PROFILE FOR THE PROPOSED SERVICE
 LATERAL WITH GROUND ELEVATIONS ABOVE THE PIPE;
  
 24. PAVEMENT RESTORATION FOR OPEN CUT/TRENCH FOR
 UTILITY CONNECTION WORKS WILL NEED TO BE IN ACCORDANCE
 WITH CITY STANDARD DETAIL GC-9. THE ROAD SHALL BE
 MILLED/RESURFACED FOR FULL LANE WIDTH OF THE TRAVEL
 LANE(S) ENCROACHED BY THE TRENCH AREA, INCLUDING A
 TRANSITION AREA OF 50 FEET ON EACH SIDE OF THE TRENCH.
 PLEASE SHOW ON THE FINAL PLANS THE EXTENT OF THE
 MILLING AND RESURFACING;
  
 25. SHOW ON THE FINAL PLANS SIZE AND MATERIAL OF ALL
 EXISTING UTILITIES ON POINSETTIA AVENUE AND 27TH STREET
 INCLUDING BUT NOT LIMITED TO WATER, SEWER, GAS,
 UNDERGROUND ELECTRIC CONDUITS ETC. PLEASE IDENTIFY THE
 SOURCE OF THE AS-BUILT INFORMATION UTILIZED FOR THE
 POTABLE WATER, SANITARY SEWER, AND STORM SEWER DESIGN;
  
 26. FOR THE FINAL WATER AND SEWER PLANS, INCLUDE A NOTE
 THAT: AS OF DECEMBER 20, 2015 THE CITY OF WEST PALM
 BEACH CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED,
 MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD
 FREE." FOR MORE INFORMATION REFER TO THE LINK BELOW:
  
 HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI
 CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL
  
 27. ALL PROPOSED FIRE DEPARTMENT CONNECTIONS SHALL BE
 WITHIN 150 FEET OF A FIRE HYDRANT AND SHALL BE WITHIN
 AN EASEMENT WITHIN THE PROPERTY. LANDSCAPE PLAN SHALL
 SHOW LOCATIONS OF ALL WATER METERS, VALVES, CLEAN-OUTS,
 LIGHT POLES, ETC. ROOT BARRIERS MAY BE REQUIRED WHERE
 PLANTINGS ARE NEAR UNDERGROUND STORMWATER, SANITARY, OR
 POTABLE WATER LINES.
  
  
 MOSTAQUE KHAN, P.E.
 LAND DEVELOPMENT ENGINEER
 [email protected]
 561-494-1124 (OFFICE)
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 01-31-2018 Cont ID  
Sent By pleduc Date 01-31-2018 Time   Rev Time 0.00
Received By pleduc Date 01-31-2018 Time 13:49 Sent To  
Notes
2018-01-31 13:52:43AFTER A REVIEW OF THE PPRC RESPONSE MEMO, DATED JANUARY
 31, 2018, FROM LINDA LOUIE, PLANNER, AND THE ATTACHED
 INFORMATION PACKET, THE PREVIOUSLY SUBMITTED FIRE
 PREVENTION BUREAU COMMENTS APPEAR TO HAVE BEEN
 ADDRESSED.
  
 HOWEVER, THE BUREAU'S APPROVAL OF THIS SUBMITTED
 PROJECT DOES NOT CONSTITUTE ITS FINAL REVIEW OR
 APPROVAL.
  
 THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT
 THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE
 REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 04-06-2017 Cont ID  
Sent By pleduc Date 04-06-2017 Time   Rev Time 0.00
Received By pleduc Date 04-06-2017 Time 09:44 Sent To  
Notes
2017-04-06 09:47:45THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A
 PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED
 TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
  
 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE
 REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
  
 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH
 THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE,
 INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES,
 INCLUDING CHAPTER 30, NEW APARTMENT BUILDINGS.
  
 FOR PLAN SUBMITTAL PURPOSES, THIS APPEARS TO BE A
 MULTIPLE OCCUPANCY CLASSIFICATION PROJECT. PLEASE
 IDENTIFY IS IT MIXED OR SEPARATED.
  
  
 6. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA
 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS
 STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE
 BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE
 BEING CONSTRUCTED. SEPARATE SHOP DRAWINGS, ARE REQUIRED
 TO BE SUBMITTED, REVIEWED AND APPROVED BY THE FIRE
 PREVENTION BUREAU PRIOR TO ANY INSTALLATION.
  
 THERE APPEARS TO BE A "PUMP ROOM" INDICATED. IS THIS A
 FIRE PUMP ROOM?
  
 FOR INFORMATIONAL PURPOSES, THE WATER SUPPLY MAY OF
 SUCH CAPACITY AND PRESSURE THAT A FIRE PUMP MAY NOT BE
 REQUIRED. A DETAILED REVIEW BY A QUALIFIED FPE MAY BE
 BENEFICIAL IN MAKING A DETERMINATION.
  
 PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004,
 FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE
 POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF
 APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT,
 CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR
 AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER
 SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA)
 AND ANY PERFORMANCE BASED INFORMATION SUCH AS
 PRE-ENGINEERED SYSTEMS.
  
 11. A CLASS NFPA 72 COMPLIANT MONITORED FIRE ALARM
 SYSTEM IS REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP
 DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED AND
 APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY
 INSTALLATION.
  
  
 12. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS
 BUILDING.
  
  
 13. ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE
 FIGHTERS EMERGENCY OPERATIONS REQUIREMENTS OF ASME
 A17.1/CSA B44, SAFETY CODE FOR ELEVATORS.
  
 ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN
 WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL
 LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET
 MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER
 ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN
 AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE
 IN THE HORIZONTAL POSITION.
  
  
  
 14. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL
 BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS,
 EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A
 PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE
 SAFETY FEATURES AND EQUIPMENT.
  
  
  
 15. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED
 ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF
 FIRE PREVENTION.
  
 ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE
 BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND
 FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET
 OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER
 ARRIVING EMERGENCY VEHICLES.
  
  
  
 16. THE PARKING DESIGN DOES NOT PROVIDE SUFFICIENT
 TURNAROUND SPACE AND THE 12' TRAFFIC LANE IS TOO NARROW
 FOR THE 20? MINIMUM FIRE LANE WIDTH THAT CAN NOT BE
 USED AS A FIRE LANE OR FIRE DEPARTMENT ACCESS. HOWEVER,
 CLOSE COORDINATION WITH THE BUREAU AND OF THE LOCATION
 OF THE FDC(S) AND FIRE HYRANTS FOR THIS PROJECT MAY
 ALLOW FOR THE ACCESS AND FIRE DEPARTMENT SUPPORT ALONG
 THE ADJACENT ROADWAYS.
  
  
  
 17. THE BUREAU'S REVIEW OF THIS SUBMITTED PROJECT DOES
 NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL.
  
  
 18. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING
 PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH
 THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  

Review Stop L LANDSCAPING
Rev No 5 Status P Date 03-20-2018 Cont ID  
Sent By rcaranci Date 03-20-2018 Time 15:21 Rev Time 0.00
Received By rcaranci Date 03-20-2018 Time 15:21 Sent To  
Notes
2018-03-20 15:22:18FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: DR. ALICE MOORE APARTMENTS Z17030019
 MARCH 20, 2018
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. SATISFIED. A TREE SURVEY WAS PROVIDED, PLEASE
 PROVIDE A TREE DISPOSITION CHART SHOWING SPECIES,
 CANOPY DIAMETER AND INDICATE IF TREES WILL BE
 PRESERVED, RELOCATED OR REMOVED. PROVIDE MITIGATION
 CALCULATIONS FOR ANY PROPOSED REMOVALS.
 A SURVEY WAS SUPPLIED. SUBMIT THE TREE DISPOSITION
 CHART, AND INCLUDE THE LARGE MAHOGANY TREE ON
 POINSETTIA IN THE PARKWAY.
 MAHOGANY TREE ON POINSETTIA NEEDS TO BE INCLUDED ON
 LIST.
  
 2. SATISFIED. PLEASE PROVIDE A SITE DATA CHART ON THE
 LANDSCAPE PLAN TO REFLECT THE REQUIRED AND PROVIDED
 OPEN SPACE AND LANDSCAPE AREA, AND SHOW CALCULATIONS
 FOR REQUIRED TREES, FLOWERING TREES AND SHRUBS.
 THE CALCULATION WILL BE BASED ON THE TOTAL AVAILABLE
 NON-BUILDING OPEN SPACE.
 EXHIBITS WERE PROVIDED, BUT CHART WAS NOT PROVIDED.
  
 3. SATISFIED. PLEASE PROVIDE LOCATIONS OF LIGHTING ON
 THE LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING.
  
 4. SATISFIED. PLEASE SHOW LOCATIONS OF WATER AND SEWER
 LINES THAT SERVICE THE BUILDING, LOCATIONS OF ABOVE
 GROUND VALVES, AND LOCATION OF DRAINAGE STRUCTURES ON
 THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH
 LANDSCAPING.
  
 5. SATISFIED. PLEASE INDICATE THE LOCATION OF THE 10
 FOOT LANDSCAPE STRIP ALONG 27TH ST REQUIRED PER SECTION
 94-209 2.(F)(1) WHERE THERE IS NO BUILDING FRONTAGE.
  
 6. SATISFIED. PLEASE PROVIDE THE DROUGHT TOLERANCE
 LEVEL FOR EACH PLANT SPECIES ON THE PLANT LIST, AND A
 CHART TO SHOW COMPLIANCE WITH SECTION 94-442(G) FLORIDA
 FRIENDLY LANDSCAPING REQUIREMENTS.
  
 7. SATISFIED. PLEASE PROVIDE SCREENING FOR ALL GROUND
 MOUNTED EQUIPMENT AND UTILITIES INCLUDING THE
 GENERATOR.
 PLEASE PROVIDE SCREENING HEDGE FOR THE WATER BACKFLOW
 PREVENTERS.
  
 8. SATISFIED. PLEASE PROVIDE A ROOT BARRIER DETAIL AND
 SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT
 INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES
 WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY
 FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS.
 ROOT BARRIER DETAIL WAS NOT LOCATED ON SHEET L-2.
  
 9. SATISFIED. PLEASE CONSIDER RELOCATING CURBS TO THE
 WHEEL STOP LOCATION TO AVOID DUPLICATION AND TO
 INCREASE THE PERVIOUS AREA ON SITE.
  
 10. SATISFIED. PLEASE PROVIDE TERMINAL ISLANDS AT THE
 END OF EACH ROW OF PARKING AND PROVIDE A LANDSCAPE
 ISLAND TO HAVE NO MORE THAN 10 PARKING SPACES IN A ROW
 PER 94-443(C)(3).
  
 11. SATISFIED. PLEASE PROVIDE TREE GRATE AND STRUCTURAL
 SOIL DETAILS AND INDICATE THEIR LOCATIONS ON THE
 LANDSCAPE PLAN.
 PLEASE PROVIDE IN ANY LOCATIONS THAT WILL HAVE TREE
 GRATES.
  
 ADDITIONAL COMMENTS 2/8/18:
 12. SATISFIED. PLEASE ADD THE REQUIRED TREE OR 3 PALMS
 IN THE TERMINAL LANDSCAPE ISLAND WEST OF THE ADA
 PARKING SPACE.
  
 13. SATISFIED. IDENTIFY WHETHER UTILITY EASEMENT HAS
 BEEN ABANDONED ALONG NORTH PROPERTY LINE.
  
 14. SATISFIED. PLEASE CORRECT THE LESS THAN SYMBOL TO
 GREATER THAN SYMBOL IN 3 LOCATIONS ON THE FLORIDA
 FRIENDLY LANDSCAPE CHART.
  
 15. SATISFIED. CORRECT THE BUFFER TREE REQUIREMENT
 CALCULATIONS TO INCLUDE THE ADDITIONAL TREE FOR THE
 PORTION OF 30 FEET FOR EACH BUFFER CALCULATION. MUST BE
 ROUNDED UP.
  
 16. SATISFIED. PLEASE EXPLAIN THE REPLACEMENT OF STREET
 TREES WITH LIGHTING POLES IN THE RIGHT OF WAY.
  
 17. SATISFIED. PLEAS ADD THE ADDITIONAL TREE AT THE
 SOUTHWEST CORNER OF THE PROPERTY. THE SAFE SIGHT
 TRIANGLE IS MEASURED FROM THE CURB, NOT PROPERTY LINE.
  
 18. SATISFIED. PALMS ARE COUNTED AT A 3 TO 1 VALUE FOR
 SUBSTITUTION FOR REQUIRED TREES. THE COUNT FOR TREES
 FALLS SHORT OF THE 65 REQUIRED TREES.
  
 19. SATISFIED. PLEASE ADD THE RELOCATED TREES TO THE
 PLANT LIST.
  
 20. SATISFIED. NEW TREES ON THE PLANT LIST MUST ALL BE
 AT THE REQUIRED 12 FEET HEIGHT.
  
 21. SATISFIED. ON SHEET A0.3, PLEASE CORRECT TO ONLY
 SHOW THE 10 PERCENT PRIVATE OPEN SPACE. AREAS IN THE
 PARKING LOT CANNOT BE COUNTED.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
  
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF
 WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A
 SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  

Review Stop L LANDSCAPING
Rev No 4 Status F Date 02-08-2018 Cont ID  
Sent By rcaranci Date 02-08-2018 Time 17:19 Rev Time 0.00
Received By rcaranci Date 02-08-2018 Time 17:19 Sent To  
Notes
2018-02-08 17:19:47FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: DR. ALICE MOORE APARTMENTS Z17030019
 FEBRUARY 8, 2018
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. PARTIALLY SATISFIED. A TREE SURVEY WAS PROVIDED,
 PLEASE PROVIDE A TREE DISPOSITION CHART SHOWING
 SPECIES, CANOPY DIAMETER AND INDICATE IF TREES WILL BE
 PRESERVED, RELOCATED OR REMOVED. PROVIDE MITIGATION
 CALCULATIONS FOR ANY PROPOSED REMOVALS.
 A SURVEY WAS SUPPLIED. SUBMIT THE TREE DISPOSITION
 CHART, AND INCLUDE THE LARGE MAHOGANY TREE ON
 POINSETTIA IN THE PARKWAY.
 MAHOGANY TREE ON POINSETTIA NEEDS TO BE INCLUDED ON
 LIST.
  
 2. NOT SATISFIED. PLEASE PROVIDE A SITE DATA CHART ON
 THE LANDSCAPE PLAN TO REFLECT THE REQUIRED AND PROVIDED
 OPEN SPACE AND LANDSCAPE AREA, AND SHOW CALCULATIONS
 FOR REQUIRED TREES, FLOWERING TREES AND SHRUBS.
 THE CALCULATION WILL BE BASED ON THE TOTAL AVAILABLE
 NON-BUILDING OPEN SPACE.
 EXHIBITS WERE PROVIDED, BUT CHART WAS NOT PROVIDED.
  
 3. SATISFIED. PLEASE PROVIDE LOCATIONS OF LIGHTING ON
 THE LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING.
  
 4. SATISFIED. PLEASE SHOW LOCATIONS OF WATER AND SEWER
 LINES THAT SERVICE THE BUILDING, LOCATIONS OF ABOVE
 GROUND VALVES, AND LOCATION OF DRAINAGE STRUCTURES ON
 THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH
 LANDSCAPING.
  
 5. SATISFIED. PLEASE INDICATE THE LOCATION OF THE 10
 FOOT LANDSCAPE STRIP ALONG 27TH ST REQUIRED PER SECTION
 94-209 2.(F)(1) WHERE THERE IS NO BUILDING FRONTAGE.
  
 6. SATISFIED. PLEASE PROVIDE THE DROUGHT TOLERANCE
 LEVEL FOR EACH PLANT SPECIES ON THE PLANT LIST, AND A
 CHART TO SHOW COMPLIANCE WITH SECTION 94-442(G) FLORIDA
 FRIENDLY LANDSCAPING REQUIREMENTS.
  
 7. PARTIALLY SATISFIED. PLEASE PROVIDE SCREENING FOR
 ALL GROUND MOUNTED EQUIPMENT AND UTILITIES INCLUDING
 THE GENERATOR.
 PLEASE PROVIDE SCREENING HEDGE FOR THE WATER BACKFLOW
 PREVENTERS.
  
 8. NOT SATISFIED. PLEASE PROVIDE A ROOT BARRIER DETAIL
 AND SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT
 INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES
 WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY
 FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS.
 ROOT BARRIER DETAIL WAS NOT LOCATED ON SHEET L-2.
  
 9. SATISFIED. PLEASE CONSIDER RELOCATING CURBS TO THE
 WHEEL STOP LOCATION TO AVOID DUPLICATION AND TO
 INCREASE THE PERVIOUS AREA ON SITE.
  
 10. SATISFIED. PLEASE PROVIDE TERMINAL ISLANDS AT THE
 END OF EACH ROW OF PARKING AND PROVIDE A LANDSCAPE
 ISLAND TO HAVE NO MORE THAN 10 PARKING SPACES IN A ROW
 PER 94-443(C)(3).
  
 11. SATISFIED. PLEASE PROVIDE TREE GRATE AND STRUCTURAL
 SOIL DETAILS AND INDICATE THEIR LOCATIONS ON THE
 LANDSCAPE PLAN.
 PLEASE PROVIDE IN ANY LOCATIONS THAT WILL HAVE TREE
 GRATES.
  
 ADDITIONAL COMMENTS 2/8/18:
 12. PLEASE ADD THE REQUIRED TREE OR 3 PALMS IN THE
 TERMINAL LANDSCAPE ISLAND WEST OF THE ADA PARKING
 SPACE.
  
 13. IDENTIFY WHETHER UTILITY EASEMENT HAS BEEN
 ABANDONED ALONG NORTH PROPERTY LINE.
  
 14. PLEASE CORRECT THE LESS THAN SYMBOL TO GREATER THAN
 SYMBOL IN 3 LOCATIONS ON THE FLORIDA FRIENDLY LANDSCAPE
 CHART.
  
 15. CORRECT THE BUFFER TREE REQUIREMENT CALCULATIONS TO
 INCLUDE THE ADDITIONAL TREE FOR THE PORTION OF 30 FEET
 FOR EACH BUFFER CALCULATION. MUST BE ROUNDED UP.
  
 16. PLEASE EXPLAIN THE REPLACEMENT OF STREET TREES WITH
 LIGHTING POLES IN THE RIGHT OF WAY.
  
 17. PLEAS ADD THE ADDITIONAL TREE AT THE SOUTHWEST
 CORNER OF THE PROPERTY. THE SAFE SIGHT TRIANGLE IS
 MEASURED FROM THE CURB, NOT PROPERTY LINE.
  
 18. PALMS ARE COUNTED AT A 3 TO 1 VALUE FOR
 SUBSTITUTION FOR REQUIRED TREES. THE COUNT FOR TREES
 FALLS SHORT OF THE 65 REQUIRED TREES.
  
 19. PLEASE ADD THE RELOCATED TREES TO THE PLANT LIST.
  
 20. NEW TREES ON THE PLANT LIST MUST ALL BE AT THE
 REQUIRED 12 FEET HEIGHT.
  
 21. ON SHEET A0.3, PLEASE CORRECT TO ONLY SHOW THE 10
 PERCENT PRIVATE OPEN SPACE. AREAS IN THE PARKING LOT
 CANNOT BE COUNTED.
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
  
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF
 WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A
 SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  

Review Stop L LANDSCAPING
Rev No 3 Status F Date 09-01-2017 Cont ID  
Sent By rcaranci Date 09-01-2017 Time 09:20 Rev Time 0.00
Received By rcaranci Date 09-01-2017 Time 09:20 Sent To  
Notes
2017-09-01 09:21:27FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: DR. ALICE MOORE APARTMENTS Z17030019
 AUGUST 31, 2017
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
  
 1. NOT SATISFIED. A TREE SURVEY WAS PROVIDED, PLEASE
 PROVIDE A TREE DISPOSITION CHART SHOWING SPECIES,
 CANOPY DIAMETER AND INDICATE IF TREES WILL BE
 PRESERVED, RELOCATED OR REMOVED. PROVIDE MITIGATION
 CALCULATIONS FOR ANY PROPOSED REMOVALS.
 A SURVEY WAS SUPPLIED. SUBMIT THE TREE DISPOSITION
 CHART, AND INCLUDE THE LARGE MAHOGANY TREE ON
 POINSETTIA IN THE PARKWAY.
  
 2. NOT SATISFIED. PLEASE PROVIDE A SITE DATA CHART ON
 THE LANDSCAPE PLAN TO REFLECT THE REQUIRED AND PROVIDED
 OPEN SPACE AND LANDSCAPE AREA, AND SHOW CALCULATIONS
 FOR REQUIRED TREES, FLOWERING TREES AND SHRUBS.
 THE CALCULATION WILL BE BASED ON THE TOTAL AVAILABLE
 NON-BUILDING OPEN SPACE.
  
 3. NOT SATISFIED. PLEASE PROVIDE LOCATIONS OF LIGHTING
 ON THE LANDSCAPE PLAN TO AVOID CONFLICTS WITH
 LANDSCAPING.
  
 4. NOT SATISFIED. PLEASE SHOW LOCATIONS OF WATER AND
 SEWER LINES THAT SERVICE THE BUILDING, LOCATIONS OF
 ABOVE GROUND VALVES, AND LOCATION OF DRAINAGE
 STRUCTURES ON THE LANDSCAPE PLAN AND RESOLVE CONFLICTS
 WITH LANDSCAPING.
  
 5. NOT SATISFIED. PLEASE INDICATE THE LOCATION OF THE
 10 FOOT LANDSCAPE STRIP ALONG 27TH ST REQUIRED PER
 SECTION 94-209 2.(F)(1) WHERE THERE IS NO BUILDING
 FRONTAGE.
  
 6. NOT SATISFIED. PLEASE PROVIDE THE DROUGHT TOLERANCE
 LEVEL FOR EACH PLANT SPECIES ON THE PLANT LIST, AND A
 CHART TO SHOW COMPLIANCE WITH SECTION 94-442(G) FLORIDA
 FRIENDLY LANDSCAPING REQUIREMENTS.
  
 7. NOT SATISFIED. PLEASE PROVIDE SCREENING FOR ALL
 GROUND MOUNTED EQUIPMENT AND UTILITIES INCLUDING THE
 GENERATOR.
  
 8. NOT SATISFIED. PLEASE PROVIDE A ROOT BARRIER DETAIL
 AND SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT
 INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES
 WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY
 FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS.
  
 9. NOT SATISFIED. PLEASE CONSIDER RELOCATING CURBS TO
 THE WHEEL STOP LOCATION TO AVOID DUPLICATION AND TO
 INCREASE THE PERVIOUS AREA ON SITE.
  
 10. SATISFIED. PLEASE PROVIDE TERMINAL ISLANDS AT THE
 END OF EACH ROW OF PARKING AND PROVIDE A LANDSCAPE
 ISLAND TO HAVE NO MORE THAN 10 PARKING SPACES IN A ROW
 PER 94-443(C)(3).
  
 11. NOT SATISFIED. PLEASE PROVIDE TREE GRATE AND
 STRUCTURAL SOIL DETAILS AND INDICATE THEIR LOCATIONS ON
 THE LANDSCAPE PLAN.
 PLEASE PROVIDE IN ANY LOCATIONS THAT WILL HAVE TREE
 GRATES.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
  
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF
 WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A
 SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  

Review Stop L LANDSCAPING
Rev No 2 Status F Date 07-13-2017 Cont ID  
Sent By rcaranci Date 07-13-2017 Time 11:46 Rev Time 0.00
Received By rcaranci Date 07-13-2017 Time 11:46 Sent To  
Notes
2017-07-13 11:47:39FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: DR. ALICE MOORE APARTMENTS Z17030019
 JULY 13, 2017
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 A LANDSCAPE PLAN WAS NOT INCLUDED IN THE RESUBMITTAL.
  
 1. NOT SATISFIED. A TREE SURVEY WAS PROVIDED, PLEASE
 PROVIDE A TREE DISPOSITION CHART SHOWING SPECIES,
 CANOPY DIAMETER AND INDICATE IF TREES WILL BE
 PRESERVED, RELOCATED OR REMOVED. PROVIDE MITIGATION
 CALCULATIONS FOR ANY PROPOSED REMOVALS.
  
 2. NOT SATISFIED. PLEASE PROVIDE A SITE DATA CHART ON
 THE LANDSCAPE PLAN TO REFLECT THE REQUIRED AND PROVIDED
 OPEN SPACE AND LANDSCAPE AREA, AND SHOW CALCULATIONS
 FOR REQUIRED TREES, FLOWERING TREES AND SHRUBS.
  
 3. NOT SATISFIED. PLEASE PROVIDE LOCATIONS OF LIGHTING
 ON THE LANDSCAPE PLAN TO AVOID CONFLICTS WITH
 LANDSCAPING.
  
 4. NOT SATISFIED. PLEASE SHOW LOCATIONS OF WATER AND
 SEWER LINES THAT SERVICE THE BUILDING, LOCATIONS OF
 ABOVE GROUND VALVES, AND LOCATION OF DRAINAGE
 STRUCTURES ON THE LANDSCAPE PLAN AND RESOLVE CONFLICTS
 WITH LANDSCAPING.
  
 5. NOT SATISFIED. PLEASE INDICATE THE LOCATION OF THE
 10 FOOT LANDSCAPE STRIP ALONG 27TH ST REQUIRED PER
 SECTION 94-209 2.(F)(1) WHERE THERE IS NO BUILDING
 FRONTAGE.
  
 6. NOT SATISFIED. PLEASE PROVIDE THE DROUGHT TOLERANCE
 LEVEL FOR EACH PLANT SPECIES ON THE PLANT LIST, AND A
 CHART TO SHOW COMPLIANCE WITH SECTION 94-442(G) FLORIDA
 FRIENDLY LANDSCAPING REQUIREMENTS.
  
 7. NOT SATISFIED. PLEASE PROVIDE SCREENING FOR ALL
 GROUND MOUNTED EQUIPMENT AND UTILITIES INCLUDING THE
 GENERATOR.
  
 8. NOT SATISFIED. PLEASE PROVIDE A ROOT BARRIER DETAIL
 AND SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT
 INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES
 WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY
 FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS.
  
 9. NOT SATISFIED. PLEASE CONSIDER RELOCATING CURBS TO
 THE WHEEL STOP LOCATION TO AVOID DUPLICATION AND TO
 INCREASE THE PERVIOUS AREA ON SITE.
  
 10. NOT SATISFIED. PLEASE PROVIDE TERMINAL ISLANDS AT
 THE END OF EACH ROW OF PARKING AND PROVIDE A LANDSCAPE
 ISLAND TO HAVE NO MORE THAN 10 PARKING SPACES IN A ROW
 PER 94-443(C)(3).
  
 11. NOT SATISFIED. ACTION
 12. PLEASE PROVIDE TREE GRATE AND STRUCTURAL SOIL
 DETAILS AND INDICATE THEIR LOCATIONS ON THE LANDSCAPE
 PLAN.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
  
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF
 WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A
 SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  
  
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 04-11-2017 Cont ID  
Sent By rcaranci Date 04-11-2017 Time 10:18 Rev Time 0.00
Received By rcaranci Date 04-11-2017 Time 10:18 Sent To  
Notes
2017-04-11 10:18:39FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: DR. ALICE MOORE APARTMENTS Z17030011
 APRIL 11, 2017
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. A TREE SURVEY WAS PROVIDED, PLEASE PROVIDE A TREE
 DISPOSITION CHART SHOWING SPECIES, CANOPY DIAMETER AND
 INDICATE IF TREES WILL BE PRESERVED, RELOCATED OR
 REMOVED. PROVIDE MITIGATION CALCULATIONS FOR ANY
 PROPOSED REMOVALS.
  
 2. PLEASE PROVIDE A SITE DATA CHART ON THE LANDSCAPE
 PLAN TO REFLECT THE REQUIRED AND PROVIDED OPEN SPACE
 AND LANDSCAPE AREA, AND SHOW CALCULATIONS FOR REQUIRED
 TREES, FLOWERING TREES AND SHRUBS.
  
 3. PLEASE PROVIDE LOCATIONS OF LIGHTING ON THE
 LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING.
  
 4. PLEASE SHOW LOCATIONS OF WATER AND SEWER LINES THAT
 SERVICE THE BUILDING, LOCATIONS OF ABOVE GROUND VALVES,
 AND LOCATION OF DRAINAGE STRUCTURES ON THE LANDSCAPE
 PLAN AND RESOLVE CONFLICTS WITH LANDSCAPING.
  
 5. PLEASE INDICATE THE LOCATION OF THE 10 FOOT
 LANDSCAPE STRIP ALONG 27TH ST REQUIRED PER SECTION
 94-209 2.(F)(1) WHERE THERE IS NO BUILDING FRONTAGE.
  
 6. PLEASE PROVIDE THE DROUGHT TOLERANCE LEVEL FOR EACH
 PLANT SPECIES ON THE PLANT LIST, AND A CHART TO SHOW
 COMPLIANCE WITH SECTION 94-442(G) FLORIDA FRIENDLY
 LANDSCAPING REQUIREMENTS.
  
 7. PLEASE PROVIDE SCREENING FOR ALL GROUND MOUNTED
 EQUIPMENT AND UTILITIES INCLUDING THE GENERATOR.
  
 8. PLEASE PROVIDE A ROOT BARRIER DETAIL AND SHOW
 LOCATIONS OF ROOT BARRIERS TO PROTECT INFRASTRUCTURE
 AND TREES FROM CONFLICTS. THIS INCLUDES WATER, SEWER,
 DRAINAGE, SIDEWALKS AND CURBS, AND ANY FIELD STRUCTURES
 THAT COULD BE IMPACTED BY TREE ROOTS.
  
 9. PLEASE CONSIDER RELOCATING CURBS TO THE WHEEL STOP
 LOCATION TO AVOID DUPLICATION AND TO INCREASE THE
 PERVIOUS AREA ON SITE.
  
 10. PLEASE PROVIDE TERMINAL ISLANDS AT THE END OF EACH
 ROW OF PARKING AND PROVIDE A LANDSCAPE ISLAND TO HAVE
 NO MORE THAN 10 PARKING SPACES IN A ROW PER
 94-443(C)(3).
  
 11. PLEASE PROVIDE TREE GRATE AND STRUCTURAL SOIL
 DETAILS AND INDICATE THEIR LOCATIONS ON THE LANDSCAPE
 PLAN.
  
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  
 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE
 STREET TREES AND RIGHT OF WAY LANDSCAPING AND
 IRRIGATION APPROVED WITH THIS PETITION.
  
 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE
 RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF
 WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A
 SEPARATE MAINTENANCE AGREEMENT WITH THE CITY.
  

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 3 Status P Date 02-14-2018 Cont ID  
Sent By tward Date 02-14-2018 Time 17:06 Rev Time 0.00
Received By tward Date 02-14-2018 Time 17:10 Sent To  
Notes
2018-02-14 17:10:07COMMENTS BELOW ARE BASED ON THE JANUARY 31, 2018 REVIEW
 PACKAGE. THEY CAN BE ADDRESSED ON THE PLANS SUBMITTED
 FOR ENGINEERING PERMIT.
  
 1. INCLUDE IN THE LEGEND ON THE PAVING & GRADING PLAN
 THE ?DOT? HATCH PATTERN.
  
 2. SHOW ON THE EROSION CONTROL PLAN INLET PROTECTION
 BMPS FOR THE ROADWAY INLETS THAT POTENTIALLY CAN
 RECEIVE RUNOFF FROM THE SITE.
  
 3. SHOW SILT FENCE IN PERVIOUS AREAS INSTEAD OF OVER
 THE SIDEWALK.
  
 4. LIST THE VERTICAL DATUM ON EACH SHEET THAT SHOWS
 ELEVATION INFORMATION.
  
 5. THE EASTERN-MOST BULBOUT ON 27TH ST IS MISSING
 RAISED CURB ON ONE SIDE.
  
 6. STORM MANHOLE NEAR NORTHEAST CORNER OF POINSETTIA
 AVENUE AND 27TH STREET IS MISLABELED AS SANITARY SEWER
 MANHOLE ON THE WATER & SEWER PLAN AND PAVING & GRADING
 PLAN. (REPEAT COMMENT)
  
 7. THERE IS A STORM SEWER PIPE LOCATED IN THE NORTH
 BOUND LANES OF POINSETTIA AVENUE THAT NEEDS TO BE SHOWN
 ON THE WATER & SEWER PLAN AND PAVING & GRADING PLAN.
 THE PROPOSED WATER LINES WILL CROSS THIS STORM PIPE TO
 CONNECT TO THE WATER MAIN. (REPEAT COMMENT)
  
 8. PLANS APPEAR VERY BUSY AND ARE DIFFICULT TO READ. IT
 MAY HELP IF LARGER SCALE BLOW-UP DETAILS ARE PROVIDED.
  
  
 TRACY L. WARD, P.E.
 ENGINEERING SERVICES DEPARTMENT
 [email protected]
 561-494-1120
  

Review Stop STORM STORMWATER
Rev No 2 Status F Date 09-05-2017 Cont ID  
Sent By tward Date 09-05-2017 Time 14:27 Rev Time 0.00
Received By tward Date 09-05-2017 Time 14:38 Sent To  
Notes
2017-09-05 14:38:01COMMENTS BELOW ARE BASED ON THE AUGUST 25, 2017 REVIEW
 PACKAGE:
  
 1. NO GRADING OR DRAINAGE PLAN WAS PROVIDED.
  
 2. NEW FEMA FIRM MAPS AND TWO FEET OF FREEBOARD ABOVE
 BASE FLOOD ELEVATION FOR STRUCTURES IN SPECIAL FLOOD
 HAZARD AREAS WILL BE EFFECTIVE ON OCTOBER 5, 2017 IF
 RESOLUTION PASSES AT SECOND READING BEFORE CITY
 COMMISSION.
  
 3. WATER & SEWER PLAN DRAWING DOES NOT MATCH THE SITE
 PLAN. THERE ARE TWO CURB LINES ALONG POINSETTIA AND
 EAST RIGHT-OF-WAY OF POINSETTIA IS SHOWN AT THE BACK OF
 WALK.
  
 4. STORM MANHOLE NEAR NORTHEAST CORNER OF POINSETTIA
 AVENUE AND 27TH STREET IS MISLABELED AS SANITARY SEWER
 MANHOLE ON THE WATER & SEWER PLAN.
  
 5. THERE IS A STORM SEWER PIPE LOCATED IN THE NORTH
 BOUND LANES OF POINSETTIA AVENUE THAT NEEDS TO BE SHOWN
 ON THE WATER & SEWER PLAN.
  
 6. DRIVEWAY APRONS SHOULD BE DESIGNED PER CITY STANDARD
 DETAIL.
  
 7. PROPOSED 2-INCH WATER SERVICE LINE WILL HAVE A
 CORPORATION STOP INSTEAD OF A GATE VALVE NEAR THE MAIN.
  
 8. REMOVE REFERENCES TO NSID IN THE UTILITY NOTES ON
 THE WATE R& SEWER PLAN.
  
 9. SHOW MILL AND OVERLAY LIMITS ON THE ENGINEERING
 DRAWING(S).
  
  
  
 TRACY L. WARD, P.E.
 ENGINEERING SERVICES DEPARTMENT
 [email protected]
 561-494-1120
  

Review Stop STORM STORMWATER
Rev No 1 Status F Date 04-12-2017 Cont ID  
Sent By tward Date 04-12-2017 Time 09:53 Rev Time 0.00
Received By tward Date 04-12-2017 Time 10:10 Sent To  
Notes
2017-04-12 10:10:32THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT
 APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP://
 WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER
 MITS-APPLICATIONS
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
 1. NO ENGINEERING PLANS WERE SUBMITTED FOR REVIEW.
  
 2. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE
 AVAILABLE AT
 HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX?.
 PLEASE REVIEW THE MAPS AND VERIFY THAT THE NEW MAPS
 WILL NOT IMPACT THE PROPOSED PROJECT.
  
 3. THE FREEBOARD REQUIREMENT FOR STRUCTURES IN A
 SPECIAL FLOOD HAZARD AREA IS ONE FOOT ABOVE BASE FLOOD
 ELEVATION.
  
 4. LOCATION OF WEST PROPERTY LINE SHOWN ON SITE PLAN
 (I.E. 32' 7" FROM CENTERLINE OF POINSETTIA AVE) DOES
 NOT AGREE WITH THE PROPOSED LOCATION OF THE PROPERTY
 LINE SHOWN ON THE PROPOSED PLAT (I.E. 49' FROM
 CENTERLINE OF POINSETTIA AVE)
  
 5. LOCATION OF SOUTH PROPERTY LINE SHOWN ON SITE PLAN
 (I.E. 34' 6" FROM CENTERLINE OF 27TH ST.) DOES NOT
 AGREE WITH THE PROPOSED LOCATION OF THE PROPERTY LINE
 SHOWN ON THE PROPOSED PLAT (I.E. 22' 4" FROM CENTERLINE
 OF 27TH ST.)
  
 6. DRAINAGE DESIGN TO MEET SFWMD CRITERIA FOR WATER
 QUALITY AND STORMWATER RUNOFF FROM THE SITE.
  
 7. CITY'S VERTICAL DATUM IS THE NATIONAL GEODETIC
 VERITCAL DATUM OF 1929. USE OF ANY OTHER VERTICAL DATUM
 WILL REQUIRE APPROVAL OF THE ENGINEERING SERVICES
 DEPARTMENT AND THE RELATIONSHIP BETWEEN THE DATUM USED
 AND NGVD 1929 SHOWN ON THE PLANS.
  
 8. PUBLIC SIDEWALKS OUTSIDE THE RIGHT-OF-WAY MAY
 REQUIRE THE LAND OWNER PROVIDE AN EASEMENT TO THE CITY.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE
 ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS
  
 2. PROVIDE A COPY OF THE SFWMD ERP FOR THIS PROPOSED
 DEVELOPMENT.
  
 3. DEMOLITION AND CONSTRUCTION PLANS WILL REQUIRE
 DEVELOPMENT OF A STORMWATER POLLUTION PREVENTION PLAN.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120
 [email protected]
  

Review Stop SURVEY SURVEYING
Rev No 2 Status P Date 03-06-2018 Cont ID  
Sent By vnoel Date 03-06-2018 Time 10:06 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2018-03-06 10:06:49PLAT HAS BEEN RECORDED.

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 04-11-2017 Cont ID  
Sent By vnoel Date 04-11-2017 Time 08:42 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2017-04-11 08:42:371. SEPARATE SUBMITTAL FOR TECHNICAL PLAT REVIEW WILL BE
 REQUIRED.
 2. SITE PLAN AND SURVEY DIMENSIONS TO NOT MATCH.
 3. CONTACT PETER BIENIEK, PUBLIC WORKS DIRECTOR FOR
 GARBAGE COLLECTION APPROVAL.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 5 Status P Date 03-26-2018 Cont ID  
Sent By llouie Date 03-26-2018 Time   Rev Time 0.00
Received By llouie Date 03-26-2018 Time   Sent To  
Notes
2018-09-26 16:59:50CONDITIONS OF APPROVAL:
  
 1.) NO STRUCTURE ALONG THE NORTH PROPERTY LINE (I.E. 6
 FT. HIGH FENCE) SHALL BE PLACED WITHIN THE 5 FT. WIDE
 UTILITY EASEMENT, UNLESS A HOLD HARMLESS AGREEMENT
 BETWEEN THE PROPERTY OWNER/TENANT AND ALL UTILITY
 PROVIDERS HAS BEEN PROVIDED TO THE CITY.
  
 2.) PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, AN APPLICATION FOR A TREE ALTERNATION
 PERMIT SHALL BE SUBMITTED, REVIEWED AND APPROVED BY THE
 DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION.
  
 3.) ALL NEW PRIVATE DEVELOPMENT, NEW CONSTRUCTION,
 RENOVATION OR REMODELING, WHERE THE TOTAL VERTICAL
 CONSTRUCTION OF ALL BUILDINGS ON A PROJECT SITE ARE
 EQUAL OR GREATER THAN $500,000 IS SUBJECT TO THE ART IN
 PUBLIC PLACES REQUIREMENTS, OUTLINED IN CHAPTER 78,
 ARTICLE V OF THE CITY'S CODE OF ORDINANCES.

Review Stop Z ZONING
Rev No 4 Status F Date 02-07-2018 Cont ID  
Sent By llouie Date 02-07-2018 Time   Rev Time 0.00
Received By llouie Date 02-07-2018 Time   Sent To  
Notes
2018-02-07 16:38:37SITE PLAN/ARCHITECTURAL COMMENTS:
  
 1.) PLEASE MAKE THE FOLLOWING CORRECTIONS TO THE
 INFORMATION PROVIDED ON SHEET G-2 (SITE PLAN AND ZONING
 TABULAR): THE CORRECT ZLDR REFERENCE FOR "BUILDING
 HEIGHT" IS "SEC. 94-215(E)(6), FIGURE VII-3" (NOT "SEC.
 94-215(G), TABLE VII-2"); THE CORRECT ZLDR REFERENCE
 FOR "MINIMUM PARCEL DIMENSIONS"IS "SEC. 94-215(H)(3),
 TABLE VII-8" (NOT "SEC. 94-215(H)3, TABLE VII-8"); THE
 CORRECT ZLDR REFERENCE FOR "BUILDING SETBACKS" IS "SEC.
 94-215(H)(2), TABLES VII-6&7" (NOT "SEC. 94-215(H)2,
 TABLE VII-6&7"); THE CORRECT ZLDR REFERENCE FOR
 "BUILDING FRONTAGE" IS "SEC. 94-215(H)(2), TABLE VII-6"
 (NOT "SEC. 94-215(H)2, TABLE VII-6&7"); REFERENCE
 "SEC.94-215(H)(3), TABLE VII-8" FOR "PRIVATE OPEN
 SPACE" REQUIREMENT; THE CORRECT ZLDR REFERENCE FOR
 "PERVIOUS" AND "IMPERVIOUS" AREA IS "SEC. 94-215(H)(3),
 TABLE VII-8" (NOT "SEC. 94-215(H)3, TABLE VII-8");
 REFERENCE "SEC. 94-486, TABLE XV-6" FOR THE 10% PARKING
 REDUCTION FOR AFFORDABLE HOUSING PROJECTS CITY-WIDE;
 THE CORRECT ZLDR REFERENCE FOR "ACCESSIBLE PARKING" IS
 "SEC. 94-485(O)(1), TABLE XV-3" (NOT "SEC. 94-485(O),
 TABLE XV-3"); REFERENCE "SEC. 94-458(Q)(1)" FOR
 "BICYCLE PARKING".
  
 2.) THE INTERIOR SIDE SETBACK IS NOTED AS BEING 20'-8"
 IN THE TABLE ON SHEET G-2; HOWEVER, THE SITE PLAN
 (SHEET A-0.1) INDICATES THAT THE SIDE SETBACK IS 20'-0"
 (HIGHLIGHTED). PLEASE ADDRESS FOR CONSISTENCY.
  
 3.) PLEASE REFERENCE/ADD NOTE IN THE TABLE ON SHEET
 (G-2) THAT THE VARIANCES HAVE BEEN APPROVED BY ZBA
 FINAL ORDER 3356.
  
 4.) NO STRUCTURES ALONG THE NORTH PROPERTY LINE (I.E. 6
 FT. HIGH FENCE) SHALL BE PLACED WITHIN THE 5 FT. WIDE
 UTILITY EASEMENT, UNLESS A HOLD HARMLESS AGREEMENT
 BETWEEN THE PROPERTY OWNER/TENANT AND UTILITY PROVIDER
 HAS BEEN PROVIDED TO THE CITY.
  
 5.) PLEASE CLARIFY IF THE PLANTERS ALONG THE SOUTH SIDE
 OF THE PROPERTY ARE FLUSHED WITH THE SIDEWALK/WALKWAYS.
 IF NOT, A DETAIL WILL NEED TO BE PROVIDED IN THE PLAN
 SET AND REFERENCED IN THE SITE PLAN.
  
 6.) PLEASE PROVIDE ADDITIONAL INFORMATION FOR THE
 ADMINISTRATIVE OFFICES ON THE GROUND FLOOR IN THE SITE
 PLAN (SHEET A0.1) TO ENSURE THAT THE ADMINISTRATIVE
 OFFICES ARE ACCESSORY TO THE RESIDENTIAL COMPONENT AND
 ARE NOT FOR COUNSELING SERVICES.
  
 7.) PROVIDE A DETAIL OF THE BICYCLE PAD THAT IS
 DEPICTED IN THE SITE PLAN (SHEET A0.1). THE DETAIL MUST
 BE CONSISTENT WITH MINIMUM DIMENSIONS REQUIRED IN THE
 CITY'S BICYCLE PARKING GUIDELINES.
  
 8.) PLEASE CLARIFY THE DIFFERENCE BETWEEN DETAIL 4 AND
 5 ON SHEET A-0.2 (SITE DETAILS)? A DETAIL WILL NEED TO
 BE ELIMINATED FROM THE SHEET IF IT IS A DUPLICATE.
  
 9.) PLEASE CLARIFY THE INTERIOR BUILDING SIDE SETBACK
 ON THE NORTH SIDE OF THE BUILDING ON SHEET A-1.1
 (GROUND LEVEL FLOOR PLAN). THE SHEET INDICATES A 20'-0"
 BUILDING SETBACK; HOWEVER, THE TABLE ON SHEET G-2
 INDICATES 20'-8".
  
 10.) PLEASE ADDRESS THE INTERIOR BUILDING SIDE SETBACK
 ON THE NORTH SIDE OF THE BUILDING ON SHEET A-1.2
 (TYPICAL LEVEL FLOOR PLAN). THE SHEET INDICATES A
 20'-8" BUILDING SETBACK; HOWEVER, THIS SETBACK IS NOT
 CONSISTENT WITH THE REST OF THE PLANS.
  
 11.) SHOW LOCATION OF THE BICYCLE RACKS IN THE NORTH
 ELEVATION ON SHEET A-2.2 (EAST AND NORTH ELEVATION).
  
 12.) LIGHT POLES SHALL COMPLY WITH THE FOLLOWING
 STANDARDS PER ZLDR S.94-209 2.(I): LIGHT POLE FIXTURES
 SHALL NOT EXCEED AN OVERALL HEIGHT OF 17.5 FT.. ABOVE
 GRADE; NO COBRA HEAD LIGHTS ARE PERMITTED; ALL LIGHTING
 SHALL BE LED OR LIGHT-EMITTING DIODE; ALL LIGHTING
 SHALL BE WEATHER AND VANDAL RESISTANT (I.E. RESISTANT
 TO GRAFFITI, SHATTERING, ETC.)
  
 13.) LIGHT POLE FIXTURES LOCATED ON THE PROPERTY SHALL
 BE SETBACK AT LEAST 5 FT. FROM THE PROPERTY LINES.
  
 14.) NEW LIGHT POLE FIXTURES LOCATED ALONG 27TH STREET,
 WITHIN THE RIGHT-OF-WAY (IN THE BULB-OUTS), SHALL BE
 EVALUATED BY THE ENGINEERING SERVICES DEPARTMENT AND
 THE CITY'S LANDSCAPE PLANNER. ADDITIONALLY, THE POLE
 FIXTURES MAY INTERFERE WITH THE PROPOSED TREES WITHIN
 THE BULB-OUTS.
  
 15.) THE ILLUMINATION SITE PLAN (SHEET E-0.1) IS NOT
 CONSISTENT WITH THE PLANS PROVIDED IN THE PACKET.
 PLEASE ADDRESS FOR CONSISTENCY.
  
  
 INSTRUCTIONS FOR RESUBMITTAL:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF TEN
 (10) PAPER COPIES, ONE )(1) REDUCED COPY IN 8.5 INCHES
 X 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 INCHES,
 AND AN ELECTRONIC COPY OF ALL PLANS. PLEASE NOTE THAT
 CHANGES ON THE RESUBMITTED PLANS MAY RESULT IN
 ADDITIONAL COMMENTS.
  
 * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
  
  
  
  
  
  
  
  

Review Stop Z ZONING
Rev No 3 Status F Date 08-29-2017 Cont ID  
Sent By llouie Date 08-29-2017 Time   Rev Time 0.00
Received By llouie Date 08-29-2017 Time   Sent To  
Notes
2017-08-29 14:14:151.) THE SITE PLAN DOES NOT ACCURATELY DEPICT THE
 EXISTING SIDEWALK AND LANDSCAPE AREA ALONG THE WEST
 SIDE OF THE PROPERTY. PLEASE REFER TO THE SURVEY OF THE
 PROPERTY AND CORRECT.
  
 2.) REFERENCE THE SECTION OF THE ZLDRS FOR THE VARIANCE
 FROM THE LANDSCAPE STRIP ALONG 27TH STREET ON SHEET
 G-2.
  
 3.) PLEASE MAKE THE FOLLOWING CORRECTIONS IN THE SITE
 DATA TABULAR ON SHEET G-2: BUILDING TYPOLOGY REFERENCE
 IS S.94-215(H), TABLE VII-7 (NOT TABLE VII-8); WHERE
 DID THE ALLOWED/REQUIRED MINIMUM LOT AREA OF 9,750 SQ.
 FT. COME FROM?; CHECK CALCULATIONS FOR THE PROVIDED
 BUILDING FRONTAGES. THE CALCULATIONS SEEM TO BE
 INCORRECT; CALCULATION FOR THE PRIVATE OPEN SPACE
 REQUIREMENT IS MISSING FROM THE TABULAR; CORRECT THE
 PROVIDED BICYCLE PARKING COUNT. PLEASE NOTE THAT ONE
 (1) BICYCLE RACK CAN ACCOMMODATE TWO (2) BICYCLES. A
 TOTAL OF FOUR (4) RACKS HAVE BEEN PROVIDED IN THE
 LATEST SITE PLAN, WHICH MEANS THERE ARE EIGHT (8)
 SPACES PROVIDED FOR BICYCLE PARKING.
  
 4.) RENDERING ON SHEET R-1 NEEDS TO BE UPDATED. IT DOES
 MATCH THE LATEST CHANGES TO THE PLANS.
  
 5.) SHOW INTERIOR SIDE (NORTH) AND REAR (EAST) BUILDING
 SETBACKS ON THE SITE PLAN.
  
 6.) ARCHITECTURAL FEATURES CANNOT PROJECT MORE THAN 2
 FT. BEYOND THE MINIMUM REQUIRED SETBACK. PLEASE
 DEMONSTRATE BY PROVIDING DIMENSIONS IN THE SITE PLAN
 FOR THE WEST AND SOUTH ELEVATIONS.
  
 7.) PROVIDE A DETAIL FOR THE BICYCLE PARKING. THE
 DETAIL SHALL BE CONSISTENT WITH THE MINIMUM STANDARDS
 OF THE CITY?S BICYCLE PARKING STANDARDS.
  
 8.) SHOW THE HEIGHT OF THE BUILDING TO THE TALLEST
 POINT IN THE ARCHITECTURAL ELEVATIONS. THE BUILDING
 HEIGHT SHOULD INCLUDE ALL CANOPIES, ARCHITECTURAL
 FEATURES, ETC.
  
 9.) SHOW DETAIL OF THE SCREENING ELEMENT AROUND THE
 TRANSFORMER. INCLUDE DIMENSIONS AND HEIGHT OF THE
 SCREEN.
  
 10.) PER THE RESPONSE LETTER TO PPRC'S COMMENTS, SENT
 ON 8/25/17 (REFERENCE: WPBDOCS 9275081 1), A
 PHOTOMETRIC PLAN WOULD BE PROVIDED WITH THE
 RESUBMITTAL; HOWEVER, NO PHOTOMETRIC PLAN CAN BE FOUND.
 PLEASE PROVIDE.
  
 11.) PRIVATE OPEN SPACE REQUIREMENT HAS NOT BEEN MET.
 PLEASE ADDRESS.
  
  
 INSTRUCTIONS FOR RESUBMITTAL:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX
 (6) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 INCHES X
 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 INCHES, AND
 AN ELECTRONIC COPY OF ALL PLANS. PLEASE NOTE THAT
 CHANGES ON THE RESUBMITTED PLANS MAY RESULT IN
 ADDITIONAL COMMENTS.
  
 * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE
 ($200.00).
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  

Review Stop Z ZONING
Rev No 2 Status F Date 07-11-2017 Cont ID  
Sent By llouie Date 07-11-2017 Time   Rev Time 0.00
Received By llouie Date 07-11-2017 Time   Sent To  
Notes
2017-07-11 11:52:03VARIANCE REQUESTED:
  
 1.) A VARIANCE FROM ZLDR S. 94-209(2)(J)(1)(M), WHICH
 REQUIRES A MINIMUM DWELLING UNIT SIZE OF 550 SQ. FT.
 AND A CUMULATIVE AVERAGE OF 800 SQ. FT. FOR ALL
 DWELLING UNITS, TO ALLOW FOR A MINIMUM DWELLING UNIT
 SIZE OF 502 SQ. FT. AND A CUMULATIVE AVERAGE OF 680 SQ.
 FT., SHALL BE APPROVED BY THE ZONING BOARD OF APPEALS
 (ZBA) PRIOR TO THE APPROVAL OF THE SITE PLAN.
  
 2.) A VARIANCE FROM ZLDR S.94-215(H)(2), WHICH REQUIRES
 A MINIMUM BUILDING SETBACK OF 10 FT., TO ALLOW A 0 FT.
 SETBACK ON 27TH STREET (SECONDARY A), MUST BE GRANTED
 BY THE ZBA PRIOR TO THE APPROVAL OF THE SITE PLAN.
  
  
 GENERAL COMMENTS:
  
 1.) THE SITE PLAN MUST BE TECHNICALLY SOUND PRIOR TO
 SCHEDULING FOR THE ZONING BOARD OF APPEALS (ZBA). THE
 REVISED SITE PLAN IS FURTHER OUT OF COMPLIANCE WITH THE
 ZONING AND LAND DEVELOPMENT REGULATIONS. THESE ISSUES
 MUST BE ADDRESSED AND/OR ADDITIONAL VARIANCES/WAIVERS
 WILL NEED TO BE REQUESTED AS PART OF THE ZBA
 APPLICATION.
  
 2.) RESPONSES TO THE PPRC'S COMMENTS SHALL BE PROVIDED
 WITH THE RESUBMITTAL.
  
 3.) JUSTIFICATION LETTER MUST CLEARLY SPECIFY THE
 PROPOSED USE FOR THE PROPERTY (I.E. WILL THE RESIDENTS
 BE UNDER THE SUPERVISION OF DOCTORS AND/OR NURSES? WHAT
 ARE THE OFFICE ON THE GROUND FLOOR FOR? ARE THESE
 OFFICES OPEN TO THE PUBLIC, ETC.). THE GROUND LEASE
 AGREEMENT PROVIDED WITH THE ORIGINAL SUBMITTAL
 INDICATES THAT THE PROJECT WILL ALSO PROVIDE "MENTAL
 HEALTH SERVICES TO RESIDENTS." STAFF MUST DETERMINE IF
 THIS PROPOSED PROJECT IS A SINGLE USE OR A MIXED USE
 PROJECT.
  
 4.) PLEASE NOTE THAT IF THE OFFICES ON THE FIRST FLOOR
 WILL BE USED TO PROVIDE TREATMENT FOR THE RESIDENTS OF
 THE APARTMENT ONLY, THEN THE USE WILL BE CONSIDERED A
 GROUP HOME AND WILL REQUIRE A CLASS B SPECIAL USE
 PERMIT; HOWEVER, IF THE OFFICES ARE OPEN TO THE GENERAL
 PUBLIC, THEN THE USE WILL BE CONSIDERED A MIX USE
 PROJECT. THEREFORE, IT IS IMPORTANT TO CLARIFY THE
 SPECIFIC USE.
  
 5.) A RE-PLAT OF THE PROPERTY IS REQUIRED.
  
 6.) PROVIDE A LETTER FROM THE PALM BEACH COUNTY TRAFFIC
 DIVISION STATING THAT THE PROJECT COMPLIES WITH THE
 TRAFFIC PERFORMANCE STANDARDS (TPS) OF THE COUNTY.
  
 7.) PROVIDE A LETTER FROM THE SCHOOL DISTRICT OF PALM
 BEACH COUNTY INDICATING THAT THE PROJECT MEETS SCHOOL
 CAPACITY STANDARDS.
  
  
 SITE PLAN/ARCHITECTURAL COMMENTS:
  
 1.) SCALE SEEMS TO BE INCORRECT; THE DIMENSIONS ARE
 INACCURATE WHEN MEASURED. PLEASE ADDRESS.
  
 2.) PROVIDE INFORMATION ON THE TOTAL AMOUNT OF OFFICE
 SQUARE FOOTAGE IN THE SITE DATA TABULAR ON SHEET G-2.
 THE AMOUNT OF OFFICE SQUARE FOOTAGE WILL DETERMINE THE
 REQUIREMENT FOR A LOADING ZONE WHICH MUST BE CLEARLY
 PROVIDED IN THE DATA.
  
 3.) PLEASE MAKE THE FOLLOWING CORRECTIONS IN THE SITE
 DATA TABULAR ON SHEET G-2: CLEARLY STATE THE NUMBER OF
 DWELLING UNITS PROPOSED FOR THE PROJECT (36 UNITS);
 CLEARLY STATE THE SQUARE FOOTAGE OF THE OFFICE
 COMPONENT; CHECK ACCURACY OF THE NET LOT AREA AND THE
 PROVIDED MINIMUM LOT AREA. THE NUMBERS SHOULD BE
 CONSISTENT WITH THE INFORMATION PROVIDED IN THE
 SURVEY/PLAT; CHECK THE BUILDING HEIGHT. THE MAXIMUM
 HEIGHT OF THE BUILDING SHALL BE MEASURED AT THE TALLEST
 POINT OF THE BUILDING. THE HEIGHT OF 42'-8" IS NOT
 ACCURATE; THE PARCEL WIDTH PROVIDED IS 92.67 FT. (NOT
 100 FT.); THE PARCEL DEPTH PROVIDED IS 312 FT. (NOT 300
 FT.); CHECK INTERIOR SIDE SETBACK PROVIDED. THE
 INTERIOR SIDE SETBACK DOES NOT SEEM TO BE 20'-8";
 PROVIDE IMPERVIOUS SURFACE REQUIREMENTS AND
 CALCULATIONS; CHECK PERVIOUS SURFACE CALCULATIONS;
 CLEARLY PROVIDE THE PARKING REQUIREMENTS. PARKING
 REQUIREMENT FOR THE OFFICE USE MUST ALSO BE INCLUDED IN
 THE CALCULATIONS; PROVIDE BICYCLE PARKING CALCULATIONS.
  
 4.) EXTEND THE WIDTH OF THE CROSSWALK ON POINSETTIA
 AVENUE SO THAT THE CROSSWALK LINES UP WITH THE
 SIDEWALK.
  
 5.) PER ZLDR S.94-209 2.(D)(2), THE CROSSWALKS ON BOTH
 27TH STREET AND POINSETTIA AVENUE SHALL BE LIGHTED FOR
 SAFETY AND SHALL REQUIRE A CHANGE IN TACTILE SURFACE
 TEXTURE. PLEASE DEMONSTRATE COMPLIANCE AND PROVIDE
 INFORMATION ON THE SURFACE TEXTURE OF THE CROSSWALK.
  
 6.) THE STRIPING DETAILS IN SHEET A-0.2 SHALL COMPLY
 WITH THE DIMENSIONS PROVIDED IN THE STALL PAINTING
 DETAIL IN ZLDR S.94-485(J). THE DETAIL PROVIDED IN
 SHEET A-0.2 INDICATES THAT THE STRIPING IS WIDER THAN
 NECESSARY AND THE EXCESS SPACE COULD BE UTILIZED TO
 PROVIDE ADDITIONAL GREEN SPACE FOR THE TERMINAL
 ISLANDS.
  
 7.) WHEEL STOPS CANNOT BE UTILIZED FOR COMPACT PARKING
 STALLS THAT ARE ONLY 16 FT. DEEP. CONSIDER A 2 FT. CURB
 OVERHANG INTO THE LANDSCAPE AREA OR PROVIDE PARKING
 STALLS THAT ARE 18 FT. DEEP WITH A WHEEL STOP.
  
 8.) ONLY 25 PERCENT OF THE TOTAL NUMBER OF PARKING
 SPACES MAY BE DESIGNATED FOR SMALL CAR USE (COMPACT
 PARKING STALLS). [ZLDR S.94-485(N)(1)]
  
 9.) EACH ROW OF PARKING SPACES SHALL BE TERMINATED BY
 LANDSCAPED ISLANDS OF NOT LESS THAN 5 FT. IN WIDTH
 (FROM THE INSIDE OF THE CURB). THE PARKING AREA DOES
 NOT MEET THIS MINIMUM REQUIREMENT. PLEASE ADDRESS.
 [ZLDR S.94-443(C)(3)]
  
 10.) ONE INTERIOR LANDSCAPE ISLAND SHALL BE REQUIRED
 FOR EVERY TEN (10) PARKING SPACES IN A ROW. INTERIOR
 LANDSCAPE ISLANDS SHALL BE AT LEAST 5 FT. WIDE MEASURED
 FROM THE INSIDE OF THE CURB AND SHALL CONTAIN AT LEAST
 ONE (1) SHADE OR FLOWERING TREE PER ROW OF PARKING. THE
 PARKING AREA DOES NOT MEET THIS MINIMUM REQUIREMENT.
 PLEASE ADDRESS. [ZLDR S.94-443(C)(3)]
  
 11.) THE DETAILS ON SHEET A-0.2 INDICATE THE USE OF A
 HANDICAP SIGN ON A POST; HOWEVER, IT IS NOT CLEAR TO
 WHERE THE SIGN WILL BE PLACED. PLEASE SHOW IN THE SITE
 PLAN WHERE THE SIGN WILL BE LOCATED.
  
 12.) BICYCLE PARKING IS REQUIRED PURSUANT TO ZLDR
 S.94-209 2.(N). PLEASE ILLUSTRATE THE LOCATION OF THE
 BICYCLE PARKING. BICYCLE PARKING IS REQUIRED FOR THE
 RESIDENTIAL AND OFFICE COMPONENT FOR THE PROJECT.
  
 13.) ON-STREET PARKING DIRECTLY AND WHOLLY ABUTTING THE
 SUBJECT PROPERTY MAY BE COUNTED TOWARDS THE PARKING
 REQUIREMENT. THIS SHOULD BE CONSIDERED SINCE THE DESIGN
 OF THE PARKING AREA IS INADEQUATE AND FAILS TO MEET THE
 MINIMUM REQUIREMENTS OF THE ZLDRS (I.E. ADEQUATE BACK
 OUT FOR VEHICLES, INSUFFICIENT SPACE PROVIDED TO OPEN
 DOORS, REQUIRED TERMINAL/LANDSCAPE ISLANDS, ETC.).
 [ZLDR S.94-485(B)(2)]
  
 14.) PLEASE PROVIDE DIMENSION AT THE ENTRANCE/EXIT ON
 27TH STREET. THE ENTRANCE/EXIT SHALL NOT EXCEED 24 FT.
 MAXIMUM. [ZLDR S.94-209 2.(E)(2)]
  
 15.) THE REQUIRED MINIMUM 5 FT. WIDE LANDSCAPE BUFFER
 STRIP ALONG THE SIDE AND REAR PROPERTY LINES SHALL BE
 MEASURED FROM THE INSIDE OF THE CURB (NOT OUTSIDE). THE
 BUFFER STRIP CURRENTLY DOES NOT MEET THIS MINIMUM
 REQUIREMENT. PLEASE ADDRESS. [ZLDR S.94-209 2.(F)]
  
 16.) STREET TREES ARE REQUIRED AND SHALL BE SPACED AT A
 MAXIMUM OF 30 FT. ON CENTER. [ZLDR S.94-209 2.(F)(2)]
  
 17.) A LANDSCAPE PLAN WAS NOT INCLUDED AS PART OF THE
 SUBMITTAL; THEREFORE, A FORMAL REVIEW OF THE LANDSCAPE
 REQUIREMENTS COULD NOT BE COMPLETED.
  
 18.) WILL THERE BE ANY SITE LIGHTING? IF SO, PLEASE
 PROVIDE A PHOTOMETRIC PLAN.
  
 19.) LIGHT POLES SHALL COMPLY WITH THE FOLLOWING
 STANDARDS PER ZLDR S.94-209 2.(I): LIGHT POLE FIXTURES
 SHALL NOT EXCEED AN OVERALL HEIGHT OF 17.5 FT. ABOVE
 GRADE; NO COBRA HEAD LIGHTS ARE PERMITTED; ALL LIGHTING
 SHALL BE LED OR LIGHT-EMITTING DIODE; ALL LIGHTING
 SHALL BE WEATHER AND VANDAL RESISTANT (I.E. RESISTANT
 TO GRAFFITI, SHATTERING, ETC.)
  
 20.) THE COLONNADE SHALL BE GUTTERED, AND DRAINAGE
 SHALL BE DEPOSITED ON SITE. [ZLDR S.94-209 2.(J)]
  
 21.) IF THE GROUND FLOOR OFFICES ARE CONSIDERED AN
 ACTIVE USE, THEN THESE OFFICES SHALL COMPLY WITH THE
 ACTIVE USE STANDARDS OF ZLDR S.94-209 2.(J), INCLUDING,
 BUT NOT LIMITED TO: MUST HAVE A TRANSPARENT CLEAR
 GLAZED AREA OF NOT LESS THAN 70 PERCENT OF THE FACADE
 AREA. PROVIDE CALCULATIONS; GROUND FLOOR WINDOW SILLS
 SHALL BE PLACED AT A MAXIMUM HEIGHT OF 24 INCHES ABOVE
 GRADE. PROVIDE ILLUSTRATIONS WITH DIMENSIONS.
  
 22.) ACTIVE USE LINER MUST HAVE A MINIMUM DEPTH OF 20
 FT. THE DEPTH OF THE CURRENT ACTIVE LINER USE SEEMS TO
 FALL SHORT OF THIS MINIMUM REQUIREMENT. ALSO, PLEASE
 PROVIDE DIMENSIONS. [ZLDR S.94-209 2.(J)]
  
 23.) PROVIDE DIMENSIONS TO DEMONSTRATE THAT THE
 COLONNADE COLUMN SPACING, WINDOWS AND DOORS ARE
 PROPORTIONED SUCH THAT THE HEIGHT OF EACH OPENING IS
 GREATER THAN ITS WIDTH. [ZLDR S.94-209 2.(J)(1)]
  
 24.) ARE THE INDIVIDUAL UNITS EQUIPPED WITH KITCHENS
 AND BATHROOMS? IF SO, PLEASE ILLUSTRATE IN THE FLOOR
 PLAN.
  
 25.) HOW DO THE RESIDENTS GET ACCESS TO THE GYM? THERE
 DOES NOT SEEM TO BE AN OPENING TO THE GYM ROOM. PLEASE
 ADDRESS.
  
 26.) THE SITE PLAN REFERENCES A 10 FT. WIDE ARCADE;
 HOWEVER, THE DESIGN INDICATES THAT IT IS A COLONNADE.
 PLEASE CORRECT.
  
 27.) COLONNADE COLUMN SPACING, WINDOWS AND DOORS SHALL
 BE PROPORTIONED SUCH THAT THE HEIGHT OF EACH OPENING IS
 GREATER THAN ITS WIDTH. [ZLDR S.94-209 2.(J)]
  
 28.) THE COLONNADE SHALL HAVE A MINIMUM 10 FT. VERTICAL
 CLEARANCE FROM THE SIDEWALK. [ZLDR S.94-209 2.(J)]
  
 29.) THE BALCONIES SHALL NOT PROJECT MORE THAN 4 FT. OF
 THE BACK OF CURB. PLEASE PROVIDE DIMENSIONS TO
 DEMONSTRATE COMPLIANCE. [ZLDR S.94-209 2.(J)(3)]
  
 30.) THE REQUIRED BUILDING FRONTAGE ALONG POINSETTIA
 AVENUE AND 27TH STREET IS 80 PERCENT. PLEASE PROVIDE
 CALCULATIONS TO DEMONSTRATE COMPLIANCE. [ZLDR
 S.94-215(H)]
  
 31.) THE COLONNADE SHALL MEET THE BUILDING SETBACK
 REQUIREMENT IF THE PORTION OF THE COLONNADE IS TO BE
 CONSIDERED PART OF THE BUILDING FRONTAGE, AND SHALL
 CONTAIN ACTIVE USE. [ZLDR S.94-215(O)]
  
 32.) THE MINIMUM OPEN SPACE REQUIREMENT FOR THE PROJECT
 IS 10 PERCENT. PLEASE PROVIDE CALCULATIONS TO
 DEMONSTRATE COMPLIANCE. [ZLDR S.94-215(J)]
  
  
 INSTRUCTIONS FOR RESUBMITTAL:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX
 (6) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 INCHES X
 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 INCHES, AND
 AN ELECTRONIC COPY OF ALL PLANS. PLEASE NOTE THAT
 CHANGES ON THE RESUBMITTED PLANS MAY RESULT IN
 ADDITIONAL COMMENTS.
  
 * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 04-07-2017 Cont ID  
Sent By llouie Date 04-07-2017 Time   Rev Time  
Received By llouie Date 04-07-2017 Time   Sent To  
Notes
2017-04-07 17:00:35GENERAL COMMENTS:
  
 1.) LOT/ROW DIMENSIONS IN THE SITE PLAN DOES NOT MATCH
 THE DIMENSIONS PROVIDED IN THE SURVEY AND PROPOSED
 REPLAT. SITE PLAN/ARCHITECTURAL COMMENTS BELOW ARE
 BASED ON THE DIMENSIONS PROVIDED IN THE SITE PLAN.
 ADJUSTING THE DIMENSIONS WILL IMPACT THE DESIGN OF THE
 PROJECT.
  
 2.) PLEASE CLARIFY THE PROPOSED USE FOR THE PROPERTY
 (I.E. WILL THE RESIDENTS BE UNDER THE SUPERVISION OF
 DOCTORS AND/OR NURSES? WHAT ARE THE OFFICES ON THE
 GROUND FLOOR FOR? ETC.). THE GROUND LEASE AGREEMENT
 PROVIDED WITH THE SUBMITTAL INDICATES THAT THE PROJECT
 WILL ALSO PROVIDE "MENTAL HEALTH SERVICES TO
 RESIDENTS." IT SHOULD BE NOTED THAT ADDITIONAL
 APPROVALS MAY BE REQUIRED (DEPENDING ON USE).
  
 3.) PROVIDE A LETTER FROM THE PALM BEACH COUNTY TRAFFIC
 DIVISION STATING THAT THE PROJECT COMPLIES WITH THE
 TRAFFIC PERFORMANCE STANDARDS (TPS) OF THE COUNTY.
  
 4.) PROVIDE A LETTER FROM THE SCHOOL DISTRICT OF PALM
 BEACH COUNTY INDICATING THAT THE PROJECT MEETS SCHOOL
 CAPACITY STANDARDS.
  
 5.) A REPLAT OF THE PROPERTY IS REQUIRED. PLEASE NOTE
 THAT PROJECT APPROVAL IS CONTINGENT UPON THE APPROVAL
 OF THE PLAT AND RECORDING OF THE PLAT WITH THE RECORDS
 OF PALM BEACH COUNTY.
  
  
 SITE PLAN/ARCHITECTURAL COMMENTS:
  
 1.) EXPAND THE WIDTH OF THE CROSSWALK ON 27TH STREET SO
 THAT IT LINES UP WITH THE SIDEWALK ALONG 27TH STREET.
  
 2.) PER ZLDR S.94-209 2.(D) C., THE CROSSWALKS ON BOTH
 27TH STREET AND POINSETTIA AVENUE SHALL REQUIRE A
 CHANGE IN TACTILE SURFACE TEXTURE. PLEASE PROVIDE
 INFORMATION ON THE SURFACE TEXTURE OF THE CROSSWALKS.
  
 3.) PROVIDE BUILDING FRONTAGE CALCULATIONS FOR BOTH
 POINSETTIA AVENUE AND 27TH STREET. A MINIMUM OF 80
 PERCENT BUILDING FRONTAGE IS REQUIRED ALONG BOTH OF
 THESE ROADWAYS. [ZLDR S.94-215(H)]
  
 4.) ACTIVE USES SHALL BE REQUIRED ALONG ALL BUILDING
 FRONTAGES. PER ZLDR S. 94-209 2.(A), "ACTIVE USE" IS A
 USE WITHIN AN ENCLOSED BUILDING DESIGNED FOR HUMAN
 OCCUPATION THAT ALSO ATTRACTS PEDESTRIAN ACTIVITY,
 PROVIDES ACCESS TO THE GENERAL PUBLIC AND CONCEALS USES
 DESIGNED FOR PARKING AND OTHER NON-ACTIVE USES. ACTIVE
 USES SHALL HAVE A DIRECT VIEW TO ADJACENT STREETS OR
 PUBLIC OPEN SPACE. THE PROPOSED OFFICES ALONG 27TH
 STREET DOES NOT SEEM TO MEET THE INTENT FOR ACTIVE USE
 PER THE CMUD REGULATIONS.
  
 5.) THE MINIMUM BUILDING SETBACK ALONG 27TH STREET
 (SECONDARY A) IS 10 FT. FROM THE PROPERTY LINE. THE
 BUILDING SETBACK ABOVE THE GROUND LEVEL DOES NOT SEEM
 TO MEET THIS REQUIREMENT. PLEASE ADDRESS. [ZLDR
 S.94-215(H)2., TABLE VII-6]
  
 6.) WILL THERE BE ANY SITE LIGHTING? IF SO, PLEASE
 PROVIDE A PHOTOMETRIC PLAN.
  
 7.) LIGHT POLES SHALL COMPLY WITH THE FOLLOWING
 STANDARDS PER ZLDR S.94-209 2.(I):
 - LIGHT POLE FIXTURES SHALL NOT EXCEED AN OVERALL
 HEIGHT OF 17.5 FT. ABOVE GRADE.
 - NO COBRA HEAD LIGHTS ARE PERMITTED.
 - ALL LIGHTING SHALL BE LED OR LIGHT-EMITTING DIODE.
 - ALL LIGHTING SHALL BE WEATHER AND VANDAL RESISTANT
 (I.E. RESISTANT TO GRAFFITI, SHATTERING, ETC.)
  
 8.) GROUND FLOOR PLAN SHOWS INTERIOR OFFICES ALONG 27TH
 STREET. PLEASE CLARIFY WHAT THESE OFFICES WILL BE USED
 FOR (I.E. WILL THESE OFFICES BE USED TO SUPPORT ONLY
 THE RESIDENTS/PATIENTS OF THE PROGRAM? OR WILL THESE
 OFFICES BE OPEN TO THE GENERAL PUBLIC?).
  
 9.) IF THE GROUND FLOOR OFFICES ARE CONSIDERED AN
 ACTIVE USE, THEN THESE OFFICES SHALL COMPLY WITH THE
 ACTIVE USE STANDARDS OF ZLDR S.94-209 2.(J), INCLUDING,
 BUT NOT LIMITED TO:
 - MUST HAVE A TRANSPARENT CLEAR GLAZED AREA OF NOT LESS
 THAN 70 PERCENT OF THE FA?ADE AREA. PROVIDE
 CALCULATIONS.
 - GROUND FLOOR WINDOW SILLS SHALL BE PLACED AT A
 MAXIMUM HEIGHT OF 24 INCHES ABOVE GRADE. PROVIDE
 ILLUSTRATIONS WITH DIMENSIONS.
  
 10.) DWELLING UNITS SHALL NOT BE LESS THAN 550 SQ. FT.
 AND THE CUMULATIVE AVERAGE OF ALL DWELLING UNITS SHALL
 NOT BE LESS THAN 800 SQ. FT. PLEASE PROVIDE
 CALCULATIONS. THE FLOOR PLAN SHOWS THAT THERE ARE
 SEVERAL UNITS THAT DO NOT MEET THE MINIMUM SQUARE
 FOOTAGE REQUIREMENT. [ZLDR S.94-209 2.(J)(1)M.]
  
 11.) ARE THE INDIVIDUAL UNITS EQUIPPED WITH KITCHENS
 AND BATHROOMS? IF SO, PLEASE ILLUSTRATE IN THE FLOOR
 PLAN.
  
 12.) EXCEPT FOR STOREFRONTS, A MINIMUM OF 30 PERCENT OF
 ALL GROUND FLOOR STREET WALLS SHALL BE FENESTRATED WITH
 WINDOWS. PLEASE DEMONSTRATE COMPLIANCE. [ZLDR S.94-209
 2.(J)(1)]
  
 13.) PROVIDE DIMENSIONS TO DEMONSTRATE THAT THE
 COLONNADE COLUMN SPACING, WINDOWS AND DOORS ARE
 PROPORTIONED SUCH THAT THE HEIGHT OF EACH OPENING IS
 GREATER THAN ITS WIDTH. [ZLDR S.94-209 2.(J)(1)]
  
 14.) COLONNADE/ARCADE: THE MINIMUM VERTICAL CLEARANCE
 FROM THE SIDEWALK LEVEL IS 10 FT. AND THE MINIMUM
 HORIZONTAL PROJECTION IS 10 FT. UNOBSTRUCTED. THE
 COLUMNS PROVIDE AN OBSTRUCTION TO THE 10 FT. HORIZONTAL
 CLEARANCE. ADDITIONALLY, PLEASE PROVIDE ADDITIONAL
 INFORMATION/DIMENSIONS TO ILLUSTRATE COMPLIANCE WITH
 THIS REQUIREMENT. [ZLDR S.94-209 2.(J)(3), S.94-215(L)]
  
 15.) GUEST PARKING SHALL BE PROMINENTLY MARKED ON-SITE
 AS "GUEST PARKING" AND SHALL NOT BE RESTRICTED IN ANY
 MANNER TO USE BY A SINGLE TENANT, OWNER, UNIT OR OTHER
 USER. [ZLDR S.94-215(M)]
  
 16.) ONE (1) BICYCLE PARKING SPACE SHALL BE PROVIDED
 FOR EVERY FIFTEEN (15) REQUIRED PARKING SPACES.
 REQUIRED BICYCLE PARKING SPACES SHALL BE PROVIDED IN A
 SECURED AREA, COVERED FROM THE ELEMENTS. A MINIMUM OF
 THREE (3) PARKING SPACES ARE REQUIRED. [ZLDR S.94-
 215(N)(2)]
  
 17.) THE MINIMUM DIMENSIONS FOR AN ON-STREET PARALLEL
 PARKING STALL IS 8.5 FT. DEEP BY 22 FT. LONG. THE DEPTH
 OF THE ON-STREET PARKING STALLS DOES NOT MEET THIS
 MINIMUM STANDARD. [ZLDR S.94-485(J), FIGURE XV-2]
  
 18.) A LANDSCAPE STRIP OF AT LEAST 10 FT. WIDE SHALL BE
 PROVIDED ALONG 27TH STREET WHERE THERE IS NO BUILDING
 FRONTAGE. [ZLDR S.94-209 2.(F)(1)]
  
 19.) EACH ROW OF PARKING SHALL BE TERMINATED BY
 LANDSCAPE ISLANDS OF NOT LESS THAN 5 FT. IN WIDTH AND
 NOT LESS THAN THE LENGTH OF THE ADJACENT PARKING STALL.
 THE LANDSCAPE ISLANDS SHALL HAVE A MINIMUM OF 2.5 FT.
 AT ITS END SO AS TO ALLOW CAR MANEUVERING. THE
 LANDSCAPE ISLANDS SHALL CONTAIN AT LEAST ONE (1) SHADE
 OR FLOWERING TREE. [ZLDR S.94-443(C)(3)]
  
  
 20.) ONE (1) INTERIOR LANDSCAPE ISLAND SHALL BE
 PROVIDED FOR EVERY TEN (10) PARKING SPACES. INTERIOR
 LANDSCAPE ISLANDS SHALL BE AT LEAST 5 FT. WIDE AND
 SHALL CONTAIN AT LEAST ONE (1) SHADE/FLOWERING TREE.
 [ZLDR S.94-443(C)(3)]
  
 21.) PROVIDE SEPARATE DIAGRAMS THAT SHOWS THE PROVISION
 FOR OPEN SPACE, PERVIOUS SURFACE AREA AND IMPERVIOUS
 SURFACE AREA. PLEASE NOTE THAT PARKING LOT BUFFERS
 CANNOT BE COUNTED TOWARDS THE PRIVATE OPEN SPACE
 REQUIREMENT. [ZLDR S.94-215(J)]
  
 22.) THE GENERATOR LOCATED AT THE NORTHEAST OF THE
 PROPERTY SHALL NOT BE VISIBLE FROM THE SIDEWALK. PLEASE
 DEMONSTRATE COMPLIANCE. [ZLDR S.94-209 2.(G)]
  
 23.) PORTICOS, CANOPIES AND COLONNADES SHALL BE
 GUTTERED, AND DRAINAGE SHALL BE DEPOSITED ON-SITE.
 [ZLDR S.94-209 2.(J)(1)]
  
 24.) SITE DATA INFORMATION/MISSING INFORMATION FROM
 PLANS:
 - EXISTING AND PROPOSED USE
 - NUMBER OF UNITS PROPOSED
 - OPEN SPACE CALCULATIONS. (REQUIRED/PROVIDED)
 - IMPERVIOUS AND PERVIOUS SURFACE CALCULATIONS
 (REQUIRED/PROVIDED)
 - OVERALL BUILDING HEIGHT IN THE ARCHITECTURAL
 ELEVATIONS (INCLUDE ALL CANOPIES, PARAPETS, ETC.)
 - PARKING STALL PAINTING DETAIL AND BICYCLE RACK DETAIL
 THAT MATCHES THE SITE PLAN
  
  
 INSTRUCTIONS FOR RESUBMITTAL:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX
 (6) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 INCHES X
 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 INCHES, AND
 AN ELECTRONIC COPY OF ALL PLANS. PLEASE NOTE THAT
 CHANGES ON THE RESUBMITTED PLANS MAY RESULT IN
 ADDITIONAL COMMENTS.
  
 * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.