Plan Review Details - Project Z17010032
Plan Review Stops For Project Z17010032
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 03-08-2017 Cont ID  
Sent By rbrown Date 03-08-2017 Time 12:13 Rev Time 0.00
Received By rbrown Date 03-08-2017 Time 12:13 Sent To  
Notes
2017-03-08 12:22:02DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR PERMITTING.
  
 2. SITE PLAN, SHEET SP1, SHOW THE TWO ACCESSIBLE
 PARKING SPACES BOTH LOCATED ADJACENT TO THE NORTH
 BUILDING WHICH INCORPORATES ONLY 5 OF THE 17 SUITES.
 ONE OF THE ACCESIBLE PARKING SPACES SHALL BE LOCATED
 ADJACENT TO THE SOUTH BUILDING SUCH THAT IT IS THE
 CLOSEST PARKING SPACE TO THE LOBBY ENTRANCE. PER
 SECTION 208.3 OF FLORIDA ACCESSIBILITY CODE, ACCESSIBLE
 PARKING SPACES ARE TO BE LOCATED ON THE SHORTEST
 POSSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING TO AN
 ACCESSIBLE ENTRANCE FOR EACH BUILDING. THE DESIGN OF
 ACCESSIBLE PARKING SPACES SHALL COMPLY WITH SECTION 502
 OF FLORIDA ACCESSIBILITY CODE
  
 3. WHEN SUBMITTED FOR PERMIT THE REVIEW WILL INCLUDE
 VERIFICATION OF COMPLIANCE WITH THE REQUIREMENTS FOR
 CHANGE OF OCCUPANCY, CHAPTER 10 OF THE FLORIDA EXISTING
 BUILDING CODE.
  
 4. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS
 AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE
 WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED
 FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS,
 GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND
 OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS,
 SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC.
  
 5. EACH SEPARATE BUILDING SHALL HAVE A SEPARATE
 ADDRESS. FOR STREET ADDRESSING, CONTACT MICHAEL ORIO,
 GIS SUPPORT SPECIALIST, AT (561) 494 1080, OR BY EMAIL:
 [email protected]
  
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status P Date 03-07-2017 Cont ID  
Sent By mkhan Date 03-07-2017 Time 14:51 Rev Time 0.00
Received By mkhan Date 03-07-2017 Time 14:51 Sent To  
Notes
2017-03-07 15:26:18CITY OF WEST PALM BEACH
 PUBLIC WORKS DEPARTMENT
 ENGINEERING DIVISION
  
 DATE: 03/07/2017
  
 Z17010032: 3805 BROADWAY ? BROADWAY MOTEL
  
 1. DRIVEWAY DIMENSIONS SHOWN ON THE SITE PLAN 'SP 1' IS
 NOT SUFFICIENT. REVISE WIDTH AND RADIUS OF THE ENTRANCE
 AND EXIT TO THE DEVELOPMENT IN THE FINAL SITE PLANS;
  
 2. IF FOUNTAIN WILL BE REACTIVATED PROPER PERMITS WILL
 BE REQUIRED FOR FLORIDA DEPARTMENT OF HEALTH SUBSECTION
 64E-9.007 (15) "POOL WASTE WATER DISPOSAL" STATES IN
 PART: "POOL WASTE WATER SHALL BE DISCHARGED THROUGH AN
 AIR GAP; DISPOSAL SHALL BE TO SANITARY SEWERS, STORM
 SEWERS, DRAINFIELDS, OR BY OTHER MEANS, IN ACCORDANCE
 WITH LOCAL MUNICIPAL AND BUILDING OFFICIAL REQUIREMENTS
 INCLUDING OBTAINING ALL NECESSARY PERMITS";
  
 3. BACKFLOW PREVENTER WILL BE REQUIRED AND CAN BE
 PERMITTED DURING PLUBING PERMIT APPLICATION;
  
 MOSTAQUE KHAN, P.E.
 LAND DEVELOPMENT ENGINEER
 [email protected]
 561-494-1124 (OFFICE)
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 03-03-2017 Cont ID  
Sent By pleduc Date 03-03-2017 Time   Rev Time 0.00
Received By pleduc Date 03-03-2017 Time 14:19 Sent To  
Notes
2017-03-03 14:24:02THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A
 PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED
 TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE
 REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH
 THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE,
 INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES.
  
 6. A NFPA 72 COMPLIANT MONITORED FIRE ALARM SYSTEM IS
 REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP DRAWINGS,
 ARE REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY
 THE FIRE PREVENTION BUREAU PRIOR TO ANY INSTALLATION.
  
 7. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL
 BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS,
 EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A
 PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE
 SAFETY FEATURES AND EQUIPMENT.
  
 8. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED
 ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF
 FIRE PREVENTION.
  
 9. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS
 BUILDING.
  
 ANY GATES SHALL BE PROVIDED WITH KNOX KEY ACCESS LOCKS,
 PADLOCKS AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS.
  
 10. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT
 DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL.
  
 11. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING
 PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH
 THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop L LANDSCAPING
Rev No 2 Status P Date 04-19-2017 Cont ID  
Sent By rcaranci Date 04-19-2017 Time 11:25 Rev Time 0.00
Received By rcaranci Date 04-19-2017 Time 11:25 Sent To  
Notes
2017-04-19 11:26:21FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: 3805 BROADWAY Z17010032
 APRIL 19, 2017
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. SATISFIED. PLEASE PROVIDE REQUIRED HEDGE AND TREES
 SUITABLE FOR PLACEMENT UNDER THE FPL LINES FOR THE EAST
 BUFFER, AND REVISE THE BUFFER CHART AND PLANT LIST TO
 INCLUDE THE ADDITIONAL PLANTS.
  
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 03-07-2017 Cont ID  
Sent By rcaranci Date 03-07-2017 Time 14:20 Rev Time 0.00
Received By rcaranci Date 03-07-2017 Time 14:20 Sent To  
Notes
2017-03-07 14:21:17FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: 3805 BROADWAY Z17010032
 MARCH 7, 2017
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. PLEASE PROVIDE REQUIRED HEDGE AND TREES SUITABLE FOR
 PLACEMENT UNDER THE FPL LINES FOR THE EAST BUFFER, AND
 REVISE THE BUFFER CHART AND PLANT LIST TO INCLUDE THE
 ADDITIONAL PLANTS.
  
  

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 1 Status P Date 03-08-2017 Cont ID  
Sent By tward Date 03-08-2017 Time 12:51 Rev Time 0.00
Received By tward Date 03-08-2017 Time 12:52 Sent To  
Notes
2017-03-08 12:52:15THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT
 APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP://
 WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER
 MITS-APPLICATIONS
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
  
 1. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE
 AVAILABLE AT
 HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX?.
 PLEASE REVIEW THE MAPS AND VERIFY THAT THE NEW MAPS
 WILL NOT IMPACT THE PROPOSED PROJECT.
  
 2. THE FREEBOARD REQUIREMENT FOR STRUCTURES IN A
 SPECIAL FLOOD HAZARD AREA IS ONE FOOT ABOVE BASE FLOOD
 ELEVATION.
  
 3. BROADWAY BLVD. IS MAINTAINED BY FDOT. FDOT APPROVAL
 WILL BE REQUIRED FOR ANY WORK WITHIN THE RIGHT-OF-WAY
 OF BROADWAY BLVD.
  
 4. LIST VERTICAL DATUM ON ENGINEERING PLAN. IF NAVD
 1988 THEN PROVIDE THE RELATIONSHIP BETWEEN NAVD 1988
 DATUM AND NGVD 1929 DATUM AT THIS LOCATION.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE
 ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120
 [email protected]
  

Review Stop SURVEY SURVEYING
Rev No 2 Status P Date 04-11-2017 Cont ID  
Sent By vnoel Date 04-11-2017 Time 09:08 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2017-04-11 09:08:03PASSED WITH CONDITION OF UNITY OF TITLE PRIOR TO C.O.

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 03-03-2017 Cont ID  
Sent By vnoel Date 03-03-2017 Time 11:18 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2017-03-03 11:26:581. UNITY OF TITLE WILL BE REQUIRED. APPLICATION CAN BE
 FOUND ONLINE THROUGH ENGINEERING SERVICES.
 2. EXISTING DUMPSTER LOCATION AND SIZE WILL NEED TO BE
 APPROVED BY SANITATION.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 03-07-2017 Cont ID  
Sent By   Date 03-07-2017 Time   Rev Time  
Received By   Date 03-07-2017 Time   Sent To  
Notes
2017-03-07 11:25:14CASE NUMBER: ZBA 3350 ? Z17010032
 PROJECT NAME: 3805 BROADWAY
 ADDRESS: 3805 BROADWAY
  
 - CONTACT PAUL GREILICH @ (561) 822-1443
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN
 (11) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG/.PDF
 FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND
 SUBMITTED TO THE PLANNING DIVISION BY 5 PM ON FRIDAY,
 3/31/17, TO BE ELIGIBLE TO BE SCHEDULED FOR THE 5/4/17
 ZONING BOARD OF APPEALS MEETING.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS
 FROM THE DATE OF THESE COMMENTS/THE PPRC MEETING (BY
 5/8/17), THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY
 FURTHER ACTION SHALL REQUIRE A NEW DEVELOPMENT
 APPLICATION.
  
 - PUBLIC HEARING NOTIFICATION SIGNAGE SHALL BE POSTED
 IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION
 94-39(I)(5) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
 1) RESTRIPE PARKING SPACES PER CODE; REFERENCE DETAIL
 PROVIDED BY STAFF
  
 2) EXPAND TWO-WAY DRIVE AISLE TO REQUIRED 24 FEET
  
 3) EXPAND ONE WAY DRIVEWAYS TO 12 FEET
  
 4) STREETWALLS AND FENCES IN FRONT OF THE BUILDING
 FACADE SHALL BE 34 TO 42 INCHES IN HEIGHT. STREETWALLS
 OR FENCES SHALL CONSIST OF A MATERIAL MATCHING THE
 ADJACENT BUILDING OR ONE OF THE FOLLOWING: INDIGENOUS
 ROCK; BLOCK AND STUCCO; DECORATIVE METAL; OR PAINTED,
 STAINED OR PRESSURE TREATED WOOD PICKETS. CHAIN LINK,
 BARBED WIRE, RAZOR WIRE, ELECTRONIC ELEMENTS OR OTHER
 HAZARDOUS MATERIALS ARE PROHIBITED. THE HEIGHT AND
 DESIGN OF THE STREETWALLS ON NONRESIDENTIAL PROPERTIES
 SHALL ALLOW FOR SURVEILLANCE OF THE PROPERTY FROM THE
 PUBLIC RIGHT-OF-WAY. (SEC. 94-220)
  
 5) EXISTING DUMPSTER LOCATION AND SIZE TO BE APPROVED
 BY SANITATION
  
 6) BUILDINGS SHOULD BE CONSIDERED FOR HISTORIC
 DESIGNATION. PLEASE CONTACT FRIEDERIKE MITTNER, CITY
 HISTORIC PRESERVATION PLANNER AT 561-822-1457 OR
 [email protected]
  
 7) TRAFFIC CONCURRENCY LETTER REQUIRED
  
 8) PROVIDE REQUIRED CITY SERVICE AND PUBLIC UTILITY
 LETTERS
  