Plan Review Details - Project Z17010008
Plan Review Stops For Project Z17010008
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 02-07-2017 Cont ID  
Sent By rbrown Date 02-07-2017 Time 20:06 Rev Time 0.00
Received By rbrown Date 02-07-2017 Time 20:06 Sent To  
Notes
2017-02-07 20:07:55DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR PERMITTING.
  
 2. EACH SEPARATE BUILDING SHALL HAVE A SEPARATE
 ADDRESS. FOR STREET ADDRESSING, CONTACT MICHAEL ORIO,
 GIS SUPPORT SPECIALIST, AT (561) 494 1080, OR BY EMAIL:
 [email protected]
  
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 2 Status P Date 03-27-2017 Cont ID  
Sent By mkhan Date 03-27-2017 Time 16:31 Rev Time 0.00
Received By mkhan Date 03-27-2017 Time 16:31 Sent To  
Notes
2017-03-27 16:32:51CITY OF WEST PALM BEACH
 PUBLIC WORKS DEPARTMENT
 ENGINEERING DIVISION
  
 DATE: 03/27/2017
  
 PROJECT NAME: R&D PAVING INDUSTRIAL SITE - 936 27TH ST.
 & 925 26TH ST. - Z17010008
  
 2ND/RE-SUBMITTAL REVIEW RESPONSE: PASSED WITH PROVISO
  
 AFTER REVIEWING THE REVISED PLANS RECEIVED ON
 3/16/2017, IT APPEARS THAT SOME OF THE COMMENTS HAVE
 BEEN ADDRESSED AND DEEM SATISFIED. WHEREAS, OTHER
 COMMENTS ARE ACKNOWLEDGED IN THE WRITTEN LETTER OF
 RESPONSE TO THE PREVIOUS PPRC COMMENTS DATED MARCH 15,
 2017. THE ACKNOWLEDGED COMMENTS ALONG WITH THE
 FOLLOWING ITEM ARE EXPECTED TO BE ADDRESSED DURING
 "ENGINEERING DEVELOPMENT APPLICATION" PHASE PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL:
  
 7. IN THE RESPONSE IT IS STATED THAT NO EXISTING
 WATERLINE WAS LOCATED AT THE PROPERTY BUT EXISTING
 WATER SERVICE CONNECTION WILL BE ABANDONED. STATEMENT
 IS NOT CLEAR. EXISTING SERVICE CONNECTION NEED TO BE
 CUT AND CAPPED AT THE MAIN INSTEAD OF ABANDONMENT (AS
 ACKNOWLEDGED IN THE RESPONSE TO THE COMMENT #13).
  
 FOLLOWING NEW COMMENTS ALSO NEED TO BE ADDRESSED IN THE
 FINAL PLANS DURING "ENGINEERING DEVELOPMENT
 APPLICATION" PHASE:
  
 1. ON THE REVISED WATER AND SEWER PLAN (SHEET 9 OF 12),
 EXISTING WATER MAIN ON 27TH ST. IS CALLED OUT AS 6 INCH
 BUT AT THE CONNECTION POINT FOR THE NEW FIRE HYDRANT
 ASSEMBLY A LABEL IS SHOWN AS: "8 INCH X 6 INCH TAPPING
 SLEEVE AND GATED VALVE". PLEASE VERIFY;
  
 2. SHOW ON THE PLAN THE SIZE AND MATERIAL FOR THE
 PROPOSED/NEW WATERLINE FROM THE METER/BACKFLOW
 PREVENTER TO THE BUILDING;
  
 3. SHOW ON THE PLAN A PROFILE FOR THE PROPOSED SANITARY
 SEWER FROM THE CLEANOUT TO THE BUILDING.
  
 MOSTAQUE KHAN, P.E.
 LAND DEVELOPMENT ENGINEER
 [email protected]
 561-494-1124 (OFFICE)
  
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 02-03-2017 Cont ID  
Sent By mkhan Date 02-03-2017 Time 09:59 Rev Time 6.00
Received By mkhan Date 02-03-2017 Time 09:59 Sent To  
Notes
2017-02-03 10:01:16CITY OF WEST PALM BEACH
 PUBLIC WORKS DEPARTMENT
 ENGINEERING DIVISION
  
 DATE: 02/03/2017
  
 Z17010008: 936 27TH ST. & 925 26TH ST. - MAINTENANCE
 BLDG. FOR R&D PAVING INDUSTRIAL SITE
  
 THIS IS AN INITIAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS, AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES.
  
 THE FOLLOWING GENERAL COMMENTS MUST BE ADDRESSED PRIOR
 TO ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL:
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE CITY'S ENGINEERING SERVICES
 DEPARTMENT. THE ENGINEERING DEVELOPMENT APPROVAL
 APPLICATION FORMS CAN BE DOWNLOADED AT:
  
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 2. PLEASE SUBMIT THE LATEST VERSION OF THE "AUTO-CALC
 CERTIFIED COST ESTIMATE FORM" FOR SUBMISSION TO CITY OF
 WEST PALM BEACH ENGINEERING SERVICES DEPARTMENT. THIS
 FORM CAN BE DOWNLOADED FROM THE FOLLOWING LINK:
  
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 3. CITY GARBAGE TRUCKS CANNOT BACK UP MORE THAN 50
 FEET. SHOW/DELINEATE THE PATH OF THE GARBAGE TRUCK IN
 THE PLAN. CONSIDER AN ALTERNATIVE LOCATION FOR THE
 DUMPSTER (MUCH CLOSER TO THE ENTRANCE) SO THAT CITY?S
 SANITATION TRUCKS CAN EASILY ACCESS AND MANEUVER;
  
 4. PROPOSED DUMPSTER PAD AND ENCLOSURE SHALL BE
 CONSISTENT WITH CITY OF WEST PALM BEACH STANDARD
 DETAIL. INCLUDE THE DETAIL ON THE PLANS DURING
 RE-SUBMITTAL. MINIMUM DIMENSION (E.G. THE GATE WIDTH
 MUST BE A MINIMUM OF 12.5 FEET) REQUIREMENTS FOR THE
 ENCLOSURE ARE LISTED IN CODE OF ORDINANCES, SECTION
 94-444(B) OF THE CODE OF ORDINANCES. CITY STANDARD
 DETAIL GC-8 MAY BE DOWNLOADED AT:
  
 HTTP://WPB.ORG/ENGINEERING/ENGINEERING-SERVICES/ENGINEE
 RING-STANDARDS/
  
 5. IF ROLL OUT TYPE DUMPSTER IS PROPOSED, PLEASE NOTE
 ON THE PLANS THAT: "OWNER IS RESPONSIBLE TO ROLL OUT
 THE DUMPSTER OUTSIDE THE ENCLOSURE PRIOR TO CITY'S
 SANITATION CREW PICK UP GARBAGE".
  
 FOLLOWING ARE WATER AND SEWER COMMENTS:
  
 6. CITY RECORD DRAWING SHOWS AN EXISTING 6-INCH DIP
 SANITARY SEWER LATERAL IS SERVING THE PROPERTY
 (CLEANOUT NEAR THE PROPERTY LINE). IT IS RECOMMENDED TO
 UTILIZE THE EXISTING LATERAL/CONNECTION;
  
 7. CITY RECORD DRAWING SHOWS AN EXISTING 1-INCH
 WATERLINE AND AN EXISTING WATER METER IS SERVING THE
 PROPERTY. IT IS RECOMMENDED TO UTILIZE THE EXISTING
 SERVICE CONNECTION;
  
 8. ANY WATERLINE THAT HAS NOT BEEN USED FOR A WHILE
 SHALL REQUIRE BAC-T TESTING PRIOR TO CONNECTION FOR NEW
 SERVICE;
  
 9. PLEASE INCLUDE THE LATEST VERSION OF THE APPLICABLE
 CITY OF WEST PALM BEACH STANDARD UTILITY DETAILS TO THE
 DETAILS SHEET. CONTACT THE ENGINEERING SERVICES
 DEPARTMENT FOR THE LATEST REVISED DETAILS IN CAD
 FORMAT. CITY'S STANDARD DETAILS (IN PDF FILE FORMAT)
 CAN BE DOWNLOADED FROM THE FOLLOWING SITE:
  
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 10. ANY NEW/PROPOSED WATER METER AND BACKFLOW PREVENTER
 SHALL BE INSTALLED PER THE CITY'S STANDARD DETAILS.
 WATER METER SHOULD BE INSIDE AN 'UTILITY EASEMENT' JUST
 INSIDE THE PROPERTY NEAR THE RIGHT-OF-WAY AND
 ACCESSIBLE;
  
 11. PERFORM SOFTDIGS DATA AND PROVIDE UTILITY CROSSING
 INFORMATION. SHOW CONFLICT INFORMATION (BOTTOM AND TOP
 OF CROSSING PIPES) AT THE CONFLICT POINTS OF ALL WATER,
 STORM AND SANITARY SEWER PIPES AS WELL AS OTHER
 FRANCHISE UTILITIES;
  
 12. PAVEMENT RESTORATION WILL BE REQUIRED AND SHALL BE
 PER THE CITY STANDARD DETAILS (GC-9 AND P-4) IF
 PROPOSED WATER AND SANITARY SEWER CONNECTION WORK IS
 PERFORMED WITHIN THE RIGHT-OF-WAY;
  
 13. EXISTING WATER SERVICE CONNECTIONS/WATER METERS
 SERVING THE PROPERTY, IF NOT USED, ARE TO BE CUT AND
 CAPPED AT THE MAIN. DE-ACTIVATED/INACTIVE PIPELINES
 LARGER THAN 2-INCH DIAMETER WILL BE REMOVED. PLEASE
 LABEL PIPE SIZE AND MATERIAL AND ADD NOTES TO THE
 UTILITY PLANS ACCORDINGLY;
  
 14. PLEASE NOTE THAT: AS OF DECEMBER 20, 2015 THE CITY
 OF WEST PALM BEACH CROSS-CONNECTION CONTROL MANUAL HAS
 BEEN REVISED, MAKING KNOWN THAT "ALL BACKFLOW DEVICES
 MUST BE LEAD FREE." FOR MORE INFORMATION REFER TO THE
 LINK BELOW:
  
 HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI
 CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL
  
 15. LANDSCAPE PLAN SHALL SHOW LOCATIONS OF ALL WATER
 METERS, VALVES, CLEAN-OUTS, LIGHT POLES, ETC. ROOT
 BARRIERS MAY BE REQUIRED WHERE PLANTINGS ARE NEAR
 UNDERGROUND STORMWATER, SANITARY, OR POTABLE WATER
 LINES.
  
 MOSTAQUE KHAN, P.E.
 LAND DEVELOPMENT ENGINEER
 [email protected]
 561-494-1124 (OFFICE)
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 02-06-2017 Cont ID  
Sent By pleduc Date 02-06-2017 Time   Rev Time 0.00
Received By pleduc Date 02-06-2017 Time 15:00 Sent To  
Notes
2017-02-06 15:27:21THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A
 PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED
 TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE
 REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. THE CONSTRUCTION OF ANY BUILDING SHALL COMPLY WITH
 THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE,
 INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES.
  
 6. FOR PLAN REVIEW SUBMITTAL, PLEASE INCLUDE THE
 OCCUPANCY TYPE, PER THE FLORIDA FIRE PREVENTION CODE.
  
 7. FOR PLAN REVIEW SUBMITTAL, PLEASE ENSURE THAT A FIRE
 LOAD CALCULATION IS INCLUDED AND THAT ADEQUATE WATER
 SUPPLY IS EXISTING OR WILL BE PROVIDED.
  
 PLEASE INCLUDE AND PROPOSED ABOVE OR BELOW GROUND FUEL
 TANKS, OIL TANKS, OR OTHER FLAMMABLE LIQUID OR
 HAZARDOUS MATERIALS STORAGE.
  
 8. ALL EXISTING OR NEW FIRE HYDRANTS PLANNED FOR THIS
 PROJECT SHALL BE CLEARLY INDICATED AND IDENTIFIED ON
 THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF
 FIRE PREVENTION.
  
 9. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL
 BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS,
 EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A
 PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE
 SAFETY FEATURES AND EQUIPMENT.
  
 PLEASE REVIEW THE CODE REQUIREMENTS FOR PROVIDING FOR
 ONLY ONE EXIT, TWO MAY BE REQUIRED PER THE APPLICABLE
 OCCUPNACY TYPE.
  
 10. IT IS HIGHLY RECOMMENDED FOR ANY ACCESS GATES THAT
 THEY BE PROVIDED WITH KNOX KEY ACCESS LOCKS, PADLOCKS
 AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS.
  
 11. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT
 DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL.
  
 12. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING
 PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH
 THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop L LANDSCAPING
Rev No 2 Status P Date 03-27-2017 Cont ID  
Sent By rcaranci Date 03-27-2017 Time 15:00 Rev Time 0.00
Received By rcaranci Date 03-27-2017 Time 15:00 Sent To  
Notes
2017-03-27 15:00:52FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: 936 27TH AND 925 26TH ST Z17010008
 MARCH 24, 2017
 STAFF HAS REVIEWED THE ZONING AND LAND DEVELOPMENT
 REGULATIONS FOR THE ABOVE REFERENCED PETITION AND
 PROVIDES THE FOLLOWING COMMENTS:
  
 1. SATISFIED. PLEASE PROVIDE CALCULATIONS FOR REQUIRED
 TREES AND SHRUBS PER SECTION 94-442 BASED ON THE 40
 PERCENT OPEN SPACE REQUIRED, AND NOT ON WHAT IS BEING
 PROVIDED. ALSO NOTE THE LIMIT OF 35 PERCENT MAXIMUM
 SUBSTITUTION OF PALMS FOR REQUIRED TREES.
  
 2. SATISFIED. PLEASE SHOW THE REQUIRED 5 FOOT LANDSCAPE
 BUFFER ADJACENT TO OTHER PROPERTIES, AND THE 10 FOOT
 LANDSCAPE BUFFER WHERE ADJACENT TO THE RIGHT OF WAY.
  
 3. CONDITIONALLY SATISFIED. THE 15 FOOT EASEMENT PER
 PLAT MAY NOT BE NEEDED. IF ABANDONED, THE LANDSCAPE
 BUFFER CAN BE MOVED TO THE PROPERTY LINE.
  
 4. SATISFIED. PLEASE SHOW THE AMOUNT OF LANDSCAPING
 PROVIDED TOWARD COMPLYING WITH THE REQUIREMENT THAT 20
 PERCENT OF THE LINEAR FEET AROUND THE EXTERIOR OF ALL
 INDUSTRIAL STRUCTURES SHALL BE PLANTED WITH TREES,
 SHRUBS OR HEDGES.
  
 5. SATISFIED. PLEASE PROVIDE THE REQUIRED HEDGE FOR 3
 SIDES OF THE DUMPSTER ENCLOSURE.
  
 6. SATISFIED. PLEASE REVISE THE LANDSCAPE AND
 ENGINEERING PLANS TO AVOID CONFLICTS BETWEEN
 LANDSCAPING AND WATER, SEWER, DRAINAGE, LIGHTING AND
 FPL EQUIPMENT. PLEASE SHOW LOCATIONS OF ALL UTILITIES
 AND EASEMENTS ON THE LANDSCAPE PLAN.
  
 7. SATISFIED. PLEASE SHOW LOCATIONS OF MECHANICAL
 EQUIPMENT SUCH AS A/C COMPRESSORS, ETC., AND PROVIDE
 SCREENING FOR ALL GROUND MOUNTED EQUIPMENT AND
 UTILITIES.
  
 8. SATISFIED. PLEASE INCLUDE A ROOT BARRIER DETAIL AND
 SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT
 INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES
 WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY
 FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS.
 CONDITIONS OF APPROVAL
  
 1. PRIOR TO ISSUANCE OF A LANDSCAPE PERMIT, THE
 APPLICANT SHALL REVISE THE LANDSCAPE PLAN TO MOVE THE
 LANDSCAPE BUFFER PLANTINGS TO THE PROPERTY LINE ALONG
 THE INTERIOR LOT LINE IN THE AREA OF THE 15 FOOT WIDE
 ABANDONED UTILITY EASEMENT.
  
  

Review Stop L LANDSCAPING
Rev No 1 Status F Date 02-07-2017 Cont ID  
Sent By rcaranci Date 02-07-2017 Time 15:10 Rev Time 0.00
Received By rcaranci Date 02-07-2017 Time 15:10 Sent To  
Notes
2017-02-07 15:10:42FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462
 PROJECT: 936 27TH AND 925 26TH ST Z17010008
 FEBRUARY 7, 2017
 STAFF HAS REVIEWED THE ZONING AND LAND DEVELOPMENT
 REGULATIONS FOR THE ABOVE REFERENCED PETITION AND
 PROVIDES THE FOLLOWING COMMENTS:
  
 1. PLEASE PROVIDE CALCULATIONS FOR REQUIRED TREES AND
 SHRUBS PER SECTION 94-442 BASED ON THE 40 PERCENT OPEN
 SPACE REQUIRED, AND NOT ON WHAT IS BEING PROVIDED. ALSO
 NOTE THE LIMIT OF 35 PERCENT MAXIMUM SUBSTITUTION OF
 PALMS FOR REQUIRED TREES.
  
 2. PLEASE SHOW THE REQUIRED 5 FOOT LANDSCAPE BUFFER
 ADJACENT TO OTHER PROPERTIES, AND THE 10 FOOT LANDSCAPE
 BUFFER WHERE ADJACENT TO THE RIGHT OF WAY.
  
 3. THE 15 FOOT EASEMENT PER PLAT MAY NOT BE NEEDED. IF
 ABANDONED, THE LANDSCAPE BUFFER CAN BE MOVED TO THE
 PROPERTY LINE.
  
 4. PLEASE SHOW THE AMOUNT OF LANDSCAPING PROVIDED
 TOWARD COMPLYING WITH THE REQUIREMENT THAT 20 PERCENT
 OF THE LINEAR FEET AROUND THE EXTERIOR OF ALL
 INDUSTRIAL STRUCTURES SHALL BE PLANTED WITH TREES,
 SHRUBS OR HEDGES.
  
 5. PLEASE PROVIDE THE REQUIRED HEDGE FOR 3 SIDES OF THE
 DUMPSTER ENCLOSURE.
  
 6. PLEASE REVISE THE LANDSCAPE AND ENGINEERING PLANS TO
 AVOID CONFLICTS BETWEEN LANDSCAPING AND WATER, SEWER,
 DRAINAGE, LIGHTING AND FPL EQUIPMENT. PLEASE SHOW
 LOCATIONS OF ALL UTILITIES AND EASEMENTS ON THE
 LANDSCAPE PLAN.
  
 7. PLEASE SHOW LOCATIONS OF MECHANICAL EQUIPMENT SUCH
 AS A/C COMPRESSORS, ETC., AND PROVIDE SCREENING FOR ALL
 GROUND MOUNTED EQUIPMENT AND UTILITIES.
  
 8. PLEASE INCLUDE A ROOT BARRIER DETAIL AND SHOW
 LOCATIONS OF ROOT BARRIERS TO PROTECT INFRASTRUCTURE
 AND TREES FROM CONFLICTS. THIS INCLUDES WATER, SEWER,
 DRAINAGE, SIDEWALKS AND CURBS, AND ANY FIELD STRUCTURES
 THAT COULD BE IMPACTED BY TREE ROOTS.
  
  

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 1 Status F Date 02-08-2017 Cont ID  
Sent By tward Date 02-08-2017 Time 10:05 Rev Time  
Received By tward Date   Time   Sent To  
Notes
2017-02-08 10:08:04THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT
 APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP://
 WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER
 MITS-APPLICATIONS
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
  
 1. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE
 AVAILABLE AT
 HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX?.
 PLEASE REVIEW THE MAPS AND VERIFY THAT THE NEW MAPS
 WILL NOT IMPACT THE PROPOSED PROJECT.
  
 2. THE FREEBOARD REQUIREMENT FOR STRUCTURES IN A
 SPECIAL FLOOD HAZARD AREA IS ONE FOOT ABOVE BASE FLOOD
 ELEVATION.
  
 3. INDICATE ON THE PAVING, GRADING AND DRAINAGE PLAN
 WHERE THE PERIMETER BERM WILL NEED TO BE CONSTRUCTED.
  
 4. ALL AREAS FOR THE STORAGE AND DISPOSAL OF GOODS,
 MERCHANDISE, AND MATERIALS SHALL BE COVERED WITH EITHER
 ASPHALT OR CONCRETE PAVING, OR CRUSHED ROCK OF SUCH
 SPECIFICATION AND DESIGN AS REQUIRED BY THE ENGINEERING
 DEPARTMENT. [SEC. 94-444 (C)(1)]
  
 5. SHOW UTILITIES ON THE LANDSCAPE PLANS.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE
 ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS
  
 2. PROVIDE ENGINEERING CALCULATIONS SIGNED AND SEALED
 BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER FOR THE
 MINIMUM REQUIRED STORM RUNOFF WATER QUALITY TREATMENT
 AND PEAK FLOOD STAGES FOR 5-YEAR 1-DAY, 25-YEAR 3-DAY
 AND 100-YEAR 3-DAY DESIGN STORMS PER SFWMD CRITERIA.
  
 3. PROVIDE A COPY OF THE SFWMD ERP FOR THIS PROPOSED
 DEVELOPMENT.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120
 [email protected]
  

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 02-03-2017 Cont ID  
Sent By vnoel Date 02-03-2017 Time 07:56 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2017-02-03 08:00:031. UNITY OF TITLE IS REQUIRED. APPLICATION IS MADE
 THROUGH THE ENGINEERING DEPT.
 2. THE 15 FOOT UE MAY ALREADY BE ABANDONED PER
 RESOLUTION NO. 146-65. CLERK IS CHECKING FOR RECORDED
 DISCLAIMER.
 3. PROVIDE COPY OF TITLE SEARCH.
 4. DUMPSTER SHOULD BE RELOCATED OFF OF MAIN DRIVEWAY.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 02-02-2017 Cont ID  
Sent By   Date 02-02-2017 Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
2017-02-02 09:28:15*****************ZONING
 REVIEW**************************
  
  -PROVIDE A DETAILS ON A TYPICAL PARKING SPACE
  -PROVIDE ADDITIONAL SCREENING TO THE 6 FOOT CHAIN LINK
 FENCE (PRIVACY FABRIC, ETC)
  -LANDSCAPING SHOULD BE INSTALLED OUTSIDE OF FENCING.
  -CONSIDER INSTALLING PEDESTRIAN SIDEWALKS ALONG
 PROPERTY ON SOUTH STREET AND 27TH STREET
  
 PLEASE LET ME KNOW WHAT QUESTIONS YOU MAY HAVE.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 561-822-1449
 [email protected]
  
  