Plan Review Details - Project Z16110016
| Plan Review Stops For Project Z16110016 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
12-14-2016 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
12-14-2016 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
12-14-2016 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2016-12-14 10:19:20 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. THE PROPOSED BUILDING WILL BE IN A FLOOD ZONE FOR | | | WHICH THE BASE FLOOD ELEVATION IS EL 7 FEET NGVD. THE | | | ELEVATION OF THE FIRST FLOOR OF THE BUILDING AND ALL | | | ASSOCIATED MECHANICAL EQUIPMENT (CHILLERS, GENERATORS | | | ETC.) SHALL BE 12 INCHES (FREEBOARD) ABOVE THAT BASE | | | FLOOD ELEVATION. | | | | | | 3. ACCESSIBLE PARKING. VALETS MAY NOT BE ABLE TO | | | OPERATE VEHICLES WHICH HAVE BEEN MODIFIED FOR THE USER, | | | SO VALET PARKING CANNOT COUNT AS ANY OF THE REQUIRED | | | ACCESSIBLE PARKING. THE PARKING TABLE ON PROJECT DATA | | | SHEET A0.0.05 STATES THAT 65 PARKING SPACES WILL BE | | | PROVIDED BUT ONLY 2 ACCESSIBLE PARKING SPACES ARE | | | PROPOSED. 3 ACCESSIBLE PARKING SPACES ARE REQIRED AS | | | THE MINIMUM NUMBER OF ACCESSIBLE PARKING SPACES | | | PROVIDED SHALL BE IN ACCORDANCE WITH SECTION 208.2 OF | | | FLORIDA ACCESSIBILITY CODE. | | | | | | 4. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 5. THIS PROJECT WILL BE SUBJECT TO ART IN PUBLIC PLACES | | | (AIPP) ASSESSMENT. FOR ADVICE ON THE PROVISION OF | | | PUBLIC ARTWORK IN LIEU OF THE AIPP ASSESSMENT, CONTACT | | | SYBILLE WELTER, ART IN PUBLIC PLACES COORDINATOR, AT | | | (561) 822-1521, OR BY EMAIL: [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
P |
Date |
03-13-2017 |
|
|
Cont ID |
|
| Sent By |
mkhan |
Date |
03-13-2017 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
mkhan |
Date |
03-13-2017 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2017-03-13 11:19:33 | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | | | | DATE: 03/13/2017 | | | | | | PROJECT NAME: PALM HARBOR MARINA HOTEL - Z16110016 - | | | 300 N FLAGLER DRIVE | | | | | | 3RD REVIEW RESPONSE ON "CONCEPTUAL ENGINEERING PLANS": | | | PASSED WITH PROVISO (SAME AND IN CONTINUATION OF THE | | | 2ND REVIEW COMMENTS) | | | | | | 3RD SUBMITTAL OF THE CIVIL PLANS WAS RECEIVED AT THE | | | DEV. SERVICES DEPT. ON 2/21/2017 WHICH HAS DID NOT HAVE | | | PROPER REVISIONS FROM THE 2ND ROUND COMMENTS: | | | | | | ORIGINAL COMMENT FROM 2ND REVIEW: FOR PAVEMENT | | | RESTORATION REFER TO CITY STANDARD DETAILS P-4 AND | | | GC-9. EXTENTS OF PAVEMENT RESTORATION SHOWN ON THE | | | PLANS (IN RESPONSE TO COMMENT NO. 18) ARE NOT ADEQUATE. | | | | | | NEW COMMENT: CONCEPTUAL ENGINEERING PLANS DO NOT SHOW | | | PAVEMENT RESTORATION PROPERLY. LIMIT SHALL BE 50-FEET | | | ON EACH SIDE OF THE PROPOSED UTILITY PIPES FROM THE | | | EDGE OF THE TRENCH AS SHOWN ON CITY'S STD. DETAILS P-4 | | | AND GC-9. PLEASE CORRECT THIS AND SHOW THE EXTENT ON | | | THE FINAL ENGINEERING PLANS DURING 'ENGINEERING REVIEW | | | APPLICATION' STAGE. FOR GARBAGE COLLECTION/SANITATION | | | PLANS NOW NEED APPROVAL FROM PETER BIENIEK, PUBLIC | | | WORKS DIRECTOR. | | | | | | TO RE-ITERATE THE MAIN PREVIOUS COMMENT/S : ALL | | | PREVIOUSLY ACKNOWLEDGED RESPONSES AND ANY AND ALL | | | COMMENTS THOSE HAVE NOT BEEN SATISFIED YET NEED TO BE | | | ADDRESSED IN THE 'FINAL ENGINEERING PLANS' WHICH NEED | | | TO BE SUBMITTED TO THE ENGINEERING DEPARTMENT ALONG | | | WITH AN 'ENGINEERING DEVELOPMENT APPLICATION' PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | MOSTAQUE KHAN, P.E. | | | LAND DEVELOPMENT ENGINEER | | | [email protected] | | | 561-494-1124 (OFFICE) | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
02-10-2017 |
|
|
Cont ID |
|
| Sent By |
mkhan |
Date |
02-10-2017 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
mkhan |
Date |
02-10-2017 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2017-02-10 09:50:21 | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | | | | DATE: 02/10/2017 | | | | | | PROJECT NAME: 300 N FLAGLER DRIVE - PALM HARBOR MARINA | | | HOTEL - Z16110016 | | | | | | 2ND REVIEW RESPONSE: PASSED WITH PROVISO | | | | | | AFTER A REVIEWING THE REVISED PLANS AND THE RESPONSES | | | TO THE PPRC COMMENTS (RECEIVED ON 1/9/2017), IT APPEARS | | | THAT MOST OF THE COMMENTS HAVE BEEN ACKNOWLEDGED AND | | | NOTED AS: "TO BE ADDRESSED AT FINAL ENGINEERING". | | | PLEASE ADDRESS THESE COMMENTS AND SUBMIT THE "FINAL | | | ENGINEERING PLANS" TO THE ENGINEERING DEPARTMENT ALONG | | | WITH AN 'ENGINEERING DEVELOPMENT APPLICATION' PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | FOR PAVEMENT RESTORATION REFER TO CITY STANDARD DETAILS | | | P-4 AND GC-9. EXTENTS OF PAVEMENT RESTORATION SHOWN ON | | | THE PLANS (IN RESPONSE TO COMMENT NO. 18) ARE NOT | | | ADEQUATE? PLEASE REVISE PLANS. | | | | | | MOSTAQUE KHAN, P.E. | | | LAND DEVELOPMENT ENGINEER | | | [email protected] | | | 561-494-1124 (OFFICE) | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
12-12-2016 |
|
|
Cont ID |
|
| Sent By |
mkhan |
Date |
12-14-2016 |
Time |
17:08 |
Rev Time |
8.00 |
| Received By |
mkhan |
Date |
12-12-2016 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2016-12-12 17:11:14 | CITY OF WEST PALM BEACH | | | PUBLIC WORKS DEPARTMENT | | | ENGINEERING DIVISION | | | | | | DATE: 12/14/2016 | | | | | | Z16110016: 300 N. FLAGLER DR. - PALM HARBOR MARINA | | | HOTEL | | | | | | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. SOLID WASTE YARDAGE CALCULATION WILL NEED TO BE | | | SUBMITTED AS PART OF THE FINAL DESIGN TO VERIFY THAT | | | THE DESIGN INCLUDES APPROPRIATE NUMBER AND SIZE OF | | | DUMPSTERS/GARBAGE RECEPTACLES. PLEASE SHOW ON THE PLAN | | | IF A COMPACTOR IS PROPOSED TO REDUCE THE YARDAGE OF | | | WASTE THAT WILL NEED TO BE COLLECTED; | | | | | | 2. PLEASE PROVIDE AN AUTOTURN ANALYSIS DEMONSTRATING | | | THE SOLID WASTE COLLECTION VEHICLE CAN ACCESS THE | | | PROPOSED DUMPSTER AND COMPACTOR LOCATIONS. THE TRASH | | | DUMPSTER/COMPACTORS MUST LOCATED IN AREAS EASILY | | | SERVICED BY THE CITY SANITATION EQUIPMENT AND MANPOWER | | | PER SECTION 74-35(A)(5) OF THE CODE OF ORDINANCES. IF A | | | ROLL-OFF COMPACTOR IS PROPOSED, PLEASE PROVIDE A LETTER | | | FROM THE PRIVATE PROVIDER VERIFYING THAT THEY CAN | | | PROVIDE SERVICE WITH THE CONFIGURATION SHOWN ON THE | | | PLANS; | | | | | | 3. PLEASE INCLUDE THE CITY OF WEST PALM BEACH STANDARD | | | DETAIL FOR THE DUMPSTER ENCLOSURE ON THE PLANS. MINIMUM | | | DIMENSIONAL (E.G. THE GATE WIDTH MUST BE A MINIMUM OF | | | 12.5 FEET) REQUIREMENTS FOR THE ENCLOSURE ARE LISTED IN | | | CODE OF ORDINANCES, SECTION 94-444(B) OF THE CODE OF | | | ORDINANCES. CITY STANDARD DETAIL GC-8 MAY BE DOWNLOADED | | | AT: | | | | | | HTTP://WPB.ORG/ENGINEERING/ENGINEERING-SERVICES/ENGINEE | | | RING-STANDARDS/ | | | | | | 4. IF ROLL OUT TYPE DUMPSTER IS PROPOSED, PLEASE NOTE | | | ON THE PLANS THAT: 'OWNER IS RESPONSIBLE TO ROLL OUT | | | THE DUMPSTER OUTSIDE THE ENCLOSURE PRIOR TO CITY?S | | | SANITATION CREW PICK UP GARBAGE'. | | | | | | 5. PLEASE REVISE THE LANDSCAPE PLAN TO SHOW LOCATIONS | | | OF ALL WATER METERS, VALVES, CLEAN-OUTS, LIGHT POLES, | | | ETC. ROOT BARRIERS MAY BE REQUIRED WHERE PLANTINGS ARE | | | NEAR UNDERGROUND STORMWATER, SANITARY, OR POTABLE WATER | | | LINES; | | | | | | 6. CITY'S GARBAGE COLLECTOR TRUCK NEEDS TO HAVE NO LESS | | | THAN 14' HIGH VERTICAL CLEARANCE AND 12' HORIZONTAL | | | CLEARANCES FOR THE TRUCK TO DRIVE THROUGH; | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL: | | | | | | 7. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING DIVISION OF THE PUBLIC | | | WORKS DEPARTMENT. THE ENGINEERING DEVELOPMENT APPROVAL | | | APPLICATION FORMS CAN BE DOWNLOADED AT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | 8. PLEASE SUBMIT THE LATEST VERSION OF THE 'AUTO-CALC | | | CERTIFIED COST ESTIMATE FORM' FOR SUBMISSION TO CITY OF | | | WEST PALM BEACH PUBLIC WORKS DEPARTMENT. THIS FORM CAN | | | BE DOWNLOADED FROM THE FOLLOWING LINK: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | 9. SUBMIT WITH THE ENGINEERING DEVELOPMENT APPROVAL | | | APPLICATION SIGNED & SEALED ENGINEER/MEP WATER AND | | | SANITARY SEWER CALCULATION (AVERAGE AND PEAK WITH | | | PEAKING FACTOR). SUBMIT CALCULATIONS TO VALIDATE METER | | | SIZE SELECTION. SHOW THESE CALCULATIONS ON THE UTILITY | | | PLAN SHEET AS WELL; | | | | | | 10. PLEASE INCLUDE APPLICABLE CITY OF WEST PALM BEACH | | | STANDARD DETAILS TO THE DETAILS SHEET. CONTACT THE | | | ENGINEERING SERVICES DEPARTMENT FOR THE LATEST REVISED | | | DETAILS IN CAD FORMAT. CITY'S STANDARD DETAILS (IN PDF | | | FILE FORMAT) CAN BE DOWNLOADED FROM THE FOLLOWING SITE: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS ARE FOR WATER AND SEWER: | | | | | | 11. PLACEMENT OF THE PROPOSED METER, BACKFLOW | | | PREVENTER, DCDA ETC. SHALL BE INSTALLED PER THE CITY'S | | | STANDARD DETAILS. REVISE THE LOCATION OF THE FIRE | | | HYDRANT. WATER METER SHOULD BE INSIDE AN 'UTILITY | | | EASEMENT' JUST INSIDE THE PROPERTY NEAR THE | | | RIGHT-OF-WAY AND ACCESSIBLE; | | | | | | 12. ENLARGE THE AREA (PREFERABLY TO A SCALE OF 1"=10') | | | TO SHOW DETAILS OF THE PROPOSED 4-INCH WATER METER; | | | | | | 13. EXISTING WATER SERVICE CONNECTIONS SERVING THE | | | PROPERTY, IF NOT USED, ARE TO BE CUT AND CAPPED AT THE | | | MAIN. DE-ACTIVATED/INACTIVE PIPELINES LARGER THAN 2" | | | DIAMETER WILL BE REMOVED. PLEASE LABEL PIPE SIZE AND | | | MATERIAL AND ADD NOTES TO THE UTILITY PLANS | | | ACCORDINGLY; | | | | | | 14. INCLUDE A PROFILE FOR THE PROPOSED SERVICE LATERAL | | | WITH GROUND ELEVATIONS ABOVE THE PIPE; | | | | | | 15. PROPOSED SANITARY SEWER MANHOLES SHALL NOT BE | | | INSTALLED ON THE EXISTING SIDEWALK. INCLUDE IN THE | | | PLANS CITY'S STANDARD DETAIL FOR MANHOLE ON THE DETAILS | | | SHEET; | | | | | | 16. PROVIDE UTILITY CROSSING INFORMATION. SHOW CONFLICT | | | INFORMATION (BOTTOM AND TOP OF CROSSING PIPES) AT THE | | | CONFLICT POINTS OF ALL WATER, STORM AND SANITARY SEWER | | | PIPES AS WELL AS OTHER FRANCHISE UTILITIES; | | | | | | 17. CCTV RECORD (VIDEO AND TV LOG) OF THE EXISTING AND | | | NEW SANITARY SEWER (FULL LENGTH FROM MH TO MH) WILL BE | | | REQUIRED AS PART OF THE PROJECT CLOSE-OUT SUBMITTALS; | | | | | | 18. PAVEMENT RESTORATION WILL BE REQUIRED FOR THE | | | PROPOSED SANITARY SEWER CONNECTION TO THE EXISTING | | | MANHOLE WITHIN THE RIGHT-OF-WAY; | | | | | | 19. PLEASE NOTE THAT: AS OF DECEMBER 20, 2015 THE CITY | | | OF WEST PALM BEACH CROSS-CONNECTION CONTROL MANUAL HAS | | | BEEN REVISED, MAKING KNOWN THAT "ALL BACKFLOW DEVICES | | | MUST BE LEAD FREE." FOR MORE INFORMATION REFER TO THE | | | LINK BELOW: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | | | | 20. THE PROPOSED FIRE DEPARTMENT CONNECTION SHALL BE | | | WITHIN 150 FEET OF A FIRE HYDRANT. LANDSCAPE PLAN SHALL | | | SHOW LOCATIONS OF ALL WATER METERS, VALVES, CLEAN-OUTS, | | | LIGHT POLES, ETC. ROOT BARRIERS MAY BE REQUIRED WHERE | | | PLANTINGS ARE NEAR UNDERGROUND STORMWATER, SANITARY, OR | | | POTABLE WATER LINES. | | | | | | MOSTAQUE KHAN, P.E. | | | LAND DEVELOPMENT ENGINEER | | | [email protected] | | | 561-494-1024 (OFFICE) | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
01-18-2017 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
01-18-2017 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
01-18-2017 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2017-01-18 11:18:09 | 2ND REVIEW RESPONSE | | | | | | | | | AFTER A REVIEW OF THE PPRC RESPONSE DATED JANUARY 6, | | | 2017, FROM ADACHE GROUP ARCHITECTS TO ANA MARIA APONTE, | | | CITY URBAN DESIGNER THE PREVIOUSLY SUBMITTED FIRE | | | PREVENTION BUREAU COMMENTS HAVE BEEN ADDRESSED WITH THE | | | EXCEPTION OF # 6 AND # 7 RELATING TO THE PROPOSED BEING | | | A HIGH RISE BUILDING. | | | | | | ACCORDING TO THE FLORIDA FIRE PREVENTION CODE, NFPA 1, | | | CHAPTER 3, DEFINITIONS - | | | | | | 3.3.30.6* HIGH-RISE BUILDING. A BUILDING WHERE THE | | | FLOOR OF AN OCCUPIABLE STORY IS GREATER THAN 75 FT (23 | | | M) ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE | | | ACCESS. | | | | | | ACCORDING TO THE PROPOSED PROJECT SUBMITTAL PLAN | | | SHEETS, SHEET A.2.1.02 INDICATES T.O. ROOF FINISH 9TH | | | FLOOR AT 74'.8" WHICH IS FROM LEVEL 1, 0'0"; HOWEVER, | | | GROUND IS INDICATED A -3'4" | | | | | | | | | IT APPEARS THE LOWEST LEVEL OF FIRE DEPARTMENT ACCESS | | | IS FROM THE GROUND LEVEL AND/OR FLAGER DRIVE WHICH | | | MOVES THE HEIGHT OF THE 9TH FLOOR OVER 75' AND MEETING | | | THE DEFINITION OF THE PROPOSED PROJECT AS A HIGH RISE. | | | | | | | | | | | | THE BUREAU CAN AGREE TO MOVE THIS PROJECT FORWARD WITH | | | APPROVAL OF THIS SUBMITTED PROJECT; HOWEVER, IT IS | | | IMPORTANT FOR DESIGN PURPOSES AND TO AVOID FUTURE PLAN | | | SUBMITTAL DELAYS TO AGREE ON A DEFINITION. | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
12-08-2016 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
12-08-2016 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
12-08-2016 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2016-12-08 17:33:51 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | | | | 6. THIS PROPOSED PROJECT IS DEFINED IN 214 FLORIDA FIRE | | | PREVENTION CODE AS A HIGH RISE AND SHALL COMPLY WITH | | | THE APPLICABLE CODE. | | | | | | NFPA 1 CHAPTER 3, DEFINITIONS | | | 3.3.30.6* HIGH-RISE BUILDING. A BUILDING WHERE THE | | | FLOOR OF AN OCCUPIABLE STORY IS GREATER THAN 75 FT (23 | | | M) ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE | | | ACCESS. | | | | | | NFPA 1, CHAPTER 20 OCCUPANCY FIRE SAFETY | | | 20.16 SPECIAL STRUCTURES AND HIGH-RISE BUILDINGS. | | | 20.16.1 APPLICATION. | | | 20.16.1.1 NEW AND EXISTING SPECIAL STRUCTURES AND | | | HIGH-RISE BUILDINGS SHALL COMPLY WITH NFPA 101. | | | | | | | | | | | | 7. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA | | | 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS | | | STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE | | | BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE | | | BEING CONSTRUCTED. SEPARATE SHOP DRAWINGS, ARE REQUIRED | | | TO BE SUBMITTED, REVIEWED AND APPROVED BY THE FIRE | | | PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | | HIGH RISES SHALL HAVE TWO SEPARATE SOURCES OF WATER | | | SUPPLY. | | | | | | 6.4.5.4* FIRE DEPARTMENT CONNECTIONS SHALL BE LOCATED | | | NOT MORE THAN 100 FT (30.5 M) FROM THE NEAREST FIRE | | | HYDRANT CONNECTED TO AN APPROVED WATER SUPPLY. | | | 18.3 WATER SUPPLIES. | | | 18.3.1* AN APPROVED WATER SUPPLY CAPABLE OF SUPPLYING | | | THE REQUIRED FIRE FLOW FOR FIRE PROTECTION SHALL BE | | | PROVIDED TO ALL PREMISES UPON WHICH FACILITIES, | | | BUILDINGS, OR PORTIONS OF BUILDINGS ARE HEREAFTER | | | CONSTRUCTED OR MOVED INTO THE JURISDICTION. | | | | | | THE APPROVED WATER SUPPLY SHALL BE IN ACCORDANCE WITH | | | SECTION 18.4. | | | | | | PER NFPA 14 SECTION 7.12.2, HIGH-RISE BUILDINGS SHALL | | | HAVE AT LEAST TWO REMOTELY LOCATED FIRE DEPARTMENT | | | CONNECTIONS FOR EACH ZONE. | | | | | | ADDITIONALLY, | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | FOR THE PROPOSED FIRE PUMP(S) , WHAT IS(ARE) THE | | | PRIMARY AND SECONDARY POWER SOURCES? | | | | | | | | | 8. A CLASS A NFPA 72 COMPLIANT MONITORED FIRE ALARM | | | SYSTEM IS REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP | | | DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED AND | | | APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY | | | INSTALLATION. | | | | | | | | | 9. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM. | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER?S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | | | | 11. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | ALL NEW FIRE HYDRANTS AND FDC'S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC'S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | ADDITIONALLY, SITE ACCESS IS LIMITED AND IT IS UNCLEAR | | | WHERE FD WILL GAIN ACCESS TO THE BUILDING AND FD | | | EQUIPMENT, I.E FDC, COMMAND ROOM, FACP, ETC. PLEASE | | | PROVIDE THE TURNING RADIUS AT THE FRONT AND WIDTH AND | | | LENGHT AT THE REAR ENTRANCES WITH AUTO TURN FOR A FD | | | LADDER TRUCK. CLOSE COORDINATION WITH THE PREVENTION | | | BUREAU IS REQUIRED FOR FINAL EQUIPMENT LOCATIONS. | | | | | | 12. COMMAND ROOM | | | THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | A. SHALL BE A MINIMUM OF 200 FT SQUARED WITH A MINIMUM | | | DIMENSION OF 10 FT. | | | B. THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | C. A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | D. SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS AND THE LOCATION | | | OF FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS | | | E. A WORK TABLE. | | | F. IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | G. THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | H. ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION OF | | | THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | I. STATUS INDICATORS AND CONTROLS FOR AIR DISTRIBUTION | | | SYSTEMS. | | | J. CONTROLS FOR UNLOCKING STAIRWAY DOORS SIMULTANEOUSLY | | | K. SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | L. EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | M. FIRE PUMP STATUS INDICATORS | | | N. GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | O. PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | P. CONTROLS REQUIRED FOR SMOKE CONTROL | | | Q. ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1. | | | R. ELEVATOR EMERGENCY OR STANDBY POWER SELECTOR | | | SWITCH(ES), WHERE EMERGENCY OR STANDBY POWER IS | | | PROVIDED | | | | | | | | | 13. RADIO | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | WEST PALM BEACH FIRE RESCUE (AHJ) ENFORCES THE -95DBM | | | NFPA 72 REQUIREMENTS FOR TWO-WAY RADIO COMMUNICATIONS | | | SYSTEMS. | | | | | | | | | 14. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | | BUILDING. | | | ADDITIONALLY, ANY GATES SHALL BE PROVIDED WITH KNOX KEY | | | ACCESS LOCKS, PADLOCKS AND/OR SWITCHES FOR 24 HOUR | | | EMERGENCY ACCESS. | | | | | | | | | 15. THE SMOKE CONTROL SYSTEM SHALL COMPLY WITH NFPA | | | 101, CHAPTER 9, BUILDING SERVICE AND FIRE PROTECTION | | | EQUIPMENT, INCLUDING: | | | | | | THE SMOKE CONTROL SYSTEMS SHALL BE INSTALLED, | | | INSPECTED, TESTED, AND MAINTAINED IN ACCORDANCE WITH | | | NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS; NFPA 204, | | | STANDARD FOR SMOKE AND HEAT VENTING; OR NATIONALLY | | | RECOGNIZED STANDARDS, ENGINEERING GUIDES, OR | | | RECOMMENDED PRACTICES, AS APPROVED BY THE AUTHORITY | | | HAVING JURISDICTION. | | | | | | THE ENGINEER OF RECORD SHALL CLEARLY IDENTIFY THE | | | INTENT OF THE SYSTEM, THE DESIGN METHOD USED, THE | | | APPROPRIATENESS OF THE METHOD USED, AND THE REQUIRED | | | MEANS OF INSPECTING, TESTING, AND MAINTAINING THE | | | SYSTEM. | | | ACCEPTANCE TESTING SHALL BE PERFORMED BY A SPECIAL | | | INSPECTOR IN ACCORDANCE WITH SECTION 9.9. | | | | | | | | | 16. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | | | | 17. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
03-15-2017 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
03-15-2017 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
03-15-2017 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2017-03-15 11:17:04 | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: PALM HARBOR MARINA HOTEL Z16110016 | | | MARCH 15, 2017 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. CONDITIONALLY SATISFIED. PLEASE PROVIDE A TREE | | | MITIGATION CHART IDENTIFYING EXISTING TREES ON THE | | | PROPERTY THAT WILL BE REMOVED AND MITIGATION PROVIDED | | | PER SECTION 94-448. | | | PLEASE PROVIDE A CHART SHOWING MITIGATION REQUIRED. | | | | | | 2. SATISFIED. PLEASE PROVIDE THE PERCENTAGE OF | | | VEGETATED AREA AND TREE CANOPY REQUIRED AND PROVIDED | | | FOR QUALIFYING PLAZA AREAS PER SECTION 94-444. | | | | | | 3. SATISFIED. PLEASE PROVIDE A LANDSCAPE PLAN FOR THE | | | ROOFTOP AMENITY DECK. | | | | | | 4. SATISFIED. PLEASE PROVIDE A COLUMN ON THE PLANT LIST | | | SHOWING DROUGHT TOLERANCE LEVELS INDICATED IN | | | WATERWISE, THE SOUTH FLORIDA WATER MANAGEMENT DISTRICT | | | PLANT AND LANDSCAPE PRACTICES GUIDE AS SPECIFIED IN | | | SECTION 94-446(G). PLEASE REVISE AND RECALCULATE TO | | | CONFIRM PERCENTAGES FOR POINTS CLAIMED. | | | | | | 5. SATISFIED. PLEASE SHOW THE TOTAL NUMBER OF PARKING | | | SPACES PROVIDED ON THE SITE PLAN DATA CHART AND USE | | | THIS NUMBER FOR THE CALCULATION OF LANDSCAPE AREA | | | REQUIRED PER SECTION 94-443(C)(3). | | | | | | 6. SATISFIED. PLEASE DEMONSTRATE COMPLIANCE WITH | | | SECTION 94-443 (C)(4) FOR THE AMOUNT OF LANDSCAPE AREA | | | REQUIRED IN THE LANDSCAPE ISLANDS PROVIDING 4 SQUARE | | | FEET FOR EACH 100 SQUARE FEET OF OTHER PAVED AREAS | | | ADDITIONAL TO PARKING SPACES. | | | | | | 7. SATISFIED. PLEASE PROVIDE A LANDSCAPE TERMINAL | | | ISLAND AND REQUIRED SHADE TREE FOR EACH ROW OF PARKING | | | IN ALL TERMINAL ISLANDS IN PARKING AREAS PER SECTION | | | 94-443 (C)(3)A. | | | THERE ARE AT LEAST THREE LOCATIONS WHERE THERE IS NO | | | SHADE TREE PROVIDED. THE TERMINAL ISLANDS ALSO DO NOT | | | MEET THE 5 FOOT MINIMUM WIDTH FOR THE FULL LENGTH OF | | | THE PARKING SPACE. | | | | | | 8. SATISFIED. PLEASE SHOW ALL UTILITIES INCLUDING | | | WATER, SEWER, AND FPL TRANSFORMERS ON THE LANDSCAPE | | | PLAN. ADJUST UTILITY LOCATIONS TO AVOID REQUIRED TREES. | | | | | | 9. SATISFIED. PLEASE INCLUDE A ROOT BARRIER DETAIL AND | | | SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT | | | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES | | | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY | | | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 10. SATISFIED. PLEASE PROVIDE SCREENING FOR ALL GROUND | | | MOUNTED EQUIPMENT AND UTILITIES. | | | | | | 11. SATISFIED. PLEASE PROVIDE DETAILS ON HOW THE | | | DUMPSTER ENCLOSURE WILL FUNCTION AND PROVIDE A COMPLETE | | | HEDGE AROUND THE THREE NON-ACCESS SIDES OF THE | | | DUMPSTER/COMPACTOR ENCLOSURE. | | | PROVIDE LANDSCAPING AS REQUIRED. | | | | | | 12. SATISFIED. PLEASE PROVIDE A BUFFER REQUIREMENTS | | | CHART LISTING THE REQUIRED BUFFER LENGTH CALCULATIONS | | | AND NUMBER OF TREES REQUIRED AND PROVIDED FOR EACH SIDE | | | OF THE PROPERTY AND LABEL THE LOCATIONS OF THE 5 FOOT | | | REQUIRED BUFFERS PER SECTION 94-442(B). | | | ADDITIONAL COMMENTS 1/27/17: | | | 13. SATISFIED. PLEASE EXPLAIN THE NEED TO ELIMINATE THE | | | IMPERVIOUS STRIP ALONG THE CURB AND INSTALL TREE GRATES | | | FOR THE ROYAL PALM STREET TREES. HAVING THE GRASS IS | | | PREFERABLE TO PAVED AREAS. PROVIDE A DETAIL OF HOW THE | | | GRATES AND SIDEWALK AREAS WOULD BE INSTALLED WITHOUT | | | NEGATIVELY AFFECTING THE PALMS. INCLUDE STRUCTURAL SOIL | | | DETAIL. | | | | | | 14. CONDITIONALLY SATISFIED. PLEASE CORRECT THE OPEN | | | SPACE CALCULATION ON SHEET LA-4 TO REFLECT THE MINIMUM | | | REQUIRED OPEN SPACE OF 40%, AND RECALCULATE SHADE | | | TREES, FLOWERING TREES AND SHRUB COUNTS REQUIRED. | | | | | | 15. SATISFIED. PLEASE REMOVE THE DESIGN OPTIONS | | | CALCULATIONS CHART FROM SHEET LA-4 DERIVED FROM SECTION | | | 94-442 (E) SITE DESIGN FLEXIBILITY, AS THIS IS NOT | | | APPLICABLE. | | | | | | 16. SATISFIED. PLEASE CHANGE THE LABEL ON THE CHART | | | SHOWING COMPLIANCE WITH SECTION 94-442 (G) FLORIDA | | | FRIENDLY LANDSCAPE REQUIREMENTS TO CORRECTLY IDENTIFY | | | IT AS SUCH. | | | | | | 17. SATISFIED. PLEASE PROVIDE CALCULATIONS TO SHOW | | | COMPLIANCE WITH SECTION 94-443 (E)(1) REQUIRING AT | | | LEAST 30 PERCENT OF THE LINEAR FEET AROUND THE BUILDING | | | IS PLANTED WITH TREES, SHRUBS OR HEDGES. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. PRIOR TO ISSUANCE OF THE TREE ALTERATION PERMIT, ALL | | | CANOPY CALCULATIONS FOR SILVER BUTTONWOOD SHALL BE | | | CORRECTED TO 150 CANOPY CREDITS AS A CATEGORY 2 TREE. | | | | | | 3. PRIOR TO ISSUANCE OF THE LANDSCAPE PERMIT, THE | | | CALCULATIONS FOR OPEN SPACE USED FOR TREE, FLOWERING | | | TREE AND SHRUB CALCULATIONS SHALL BE REVISED TO 40 | | | PERCENT OF THE SITE AREA EQUAL TO 25,804 SQ FT. | | | | | | 4. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | | | | 5. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
01-27-2017 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-27-2017 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-27-2017 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2017-01-27 10:45:02 | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: PALM HARBOR MARINA HOTEL Z16110016 | | | JANUARY 26, 2017 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. NOT SATISFIED. PLEASE PROVIDE A TREE MITIGATION | | | CHART IDENTIFYING EXISTING TREES ON THE PROPERTY THAT | | | WILL BE REMOVED AND MITIGATION PROVIDED PER SECTION | | | 94-448. | | | PLEASE PROVIDE A CHART SHOWING MITIGATION REQUIRED. | | | | | | 2. SATISFIED. PLEASE PROVIDE THE PERCENTAGE OF | | | VEGETATED AREA AND TREE CANOPY REQUIRED AND PROVIDED | | | FOR QUALIFYING PLAZA AREAS PER SECTION 94-444. | | | | | | 3. SATISFIED. PLEASE PROVIDE A LANDSCAPE PLAN FOR THE | | | ROOFTOP AMENITY DECK. | | | | | | 4. SATISFIED. PLEASE PROVIDE A COLUMN ON THE PLANT LIST | | | SHOWING DROUGHT TOLERANCE LEVELS INDICATED IN | | | WATERWISE, THE SOUTH FLORIDA WATER MANAGEMENT DISTRICT | | | PLANT AND LANDSCAPE PRACTICES GUIDE AS SPECIFIED IN | | | SECTION 94-446(G). PLEASE REVISE AND RECALCULATE TO | | | CONFIRM PERCENTAGES FOR POINTS CLAIMED. | | | | | | 5. SATISFIED. PLEASE SHOW THE TOTAL NUMBER OF PARKING | | | SPACES PROVIDED ON THE SITE PLAN DATA CHART AND USE | | | THIS NUMBER FOR THE CALCULATION OF LANDSCAPE AREA | | | REQUIRED PER SECTION 94-443(C)(3). | | | | | | 6. SATISFIED. PLEASE DEMONSTRATE COMPLIANCE WITH | | | SECTION 94-443 (C)(4) FOR THE AMOUNT OF LANDSCAPE AREA | | | REQUIRED IN THE LANDSCAPE ISLANDS PROVIDING 4 SQUARE | | | FEET FOR EACH 100 SQUARE FEET OF OTHER PAVED AREAS | | | ADDITIONAL TO PARKING SPACES. | | | | | | 7. NOT SATISFIED. PLEASE PROVIDE A LANDSCAPE TERMINAL | | | ISLAND AND REQUIRED SHADE TREE FOR EACH ROW OF PARKING | | | IN ALL TERMINAL ISLANDS IN PARKING AREAS PER SECTION | | | 94-443 (C)(3)A. | | | THERE ARE AT LEAST THREE LOCATIONS WHERE THERE IS NO | | | SHADE TREE PROVIDED. THE TERMINAL ISLANDS ALSO DO NOT | | | MEET THE 5 FOOT MINIMUM WIDTH FOR THE FULL LENGTH OF | | | THE PARKING SPACE. | | | | | | 8. SATISFIED. PLEASE SHOW ALL UTILITIES INCLUDING | | | WATER, SEWER, AND FPL TRANSFORMERS ON THE LANDSCAPE | | | PLAN. ADJUST UTILITY LOCATIONS TO AVOID REQUIRED TREES. | | | | | | 9. SATISFIED. PLEASE INCLUDE A ROOT BARRIER DETAIL AND | | | SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT | | | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES | | | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY | | | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 10. SATISFIED. PLEASE PROVIDE SCREENING FOR ALL GROUND | | | MOUNTED EQUIPMENT AND UTILITIES. | | | | | | 11. NOT SATISFIED. PLEASE PROVIDE DETAILS ON HOW THE | | | DUMPSTER ENCLOSURE WILL FUNCTION AND PROVIDE A COMPLETE | | | HEDGE AROUND THE THREE NON-ACCESS SIDES OF THE | | | DUMPSTER/COMPACTOR ENCLOSURE. | | | PROVIDE LANDSCAPING AS REQUIRED. | | | | | | 12. SATISFIED. PLEASE PROVIDE A BUFFER REQUIREMENTS | | | CHART LISTING THE REQUIRED BUFFER LENGTH CALCULATIONS | | | AND NUMBER OF TREES REQUIRED AND PROVIDED FOR EACH SIDE | | | OF THE PROPERTY AND LABEL THE LOCATIONS OF THE 5 FOOT | | | REQUIRED BUFFERS PER SECTION 94-442(B). | | | ADDITIONAL COMMENTS 1/27/17: | | | 13. PLEASE EXPLAIN THE NEED TO ELIMINATE THE IMPERVIOUS | | | STRIP ALONG THE CURB AND INSTALL TREE GRATES FOR THE | | | ROYAL PALM STREET TREES. HAVING THE GRASS IS PREFERABLE | | | TO PAVED AREAS. PROVIDE A DETAIL OF HOW THE GRATES AND | | | SIDEWALK AREAS WOULD BE INSTALLED WITHOUT NEGATIVELY | | | AFFECTING THE PALMS. INCLUDE STRUCTURAL SOIL DETAIL. | | | | | | 14. PLEASE CORRECT THE OPEN SPACE CALCULATION ON SHEET | | | LA-4 TO REFLECT THE MINIMUM REQUIRED OPEN SPACE OF 40%, | | | AND RECALCULATE SHADE TREES, FLOWERING TREES AND SHRUB | | | COUNTS REQUIRED. | | | | | | 15. PLEASE REMOVE THE DESIGN OPTIONS CALCULATIONS CHART | | | FROM SHEET LA-4 DERIVED FROM SECTION 94-442 (E) SITE | | | DESIGN FLEXIBILITY, AS THIS IS NOT APPLICABLE. | | | | | | 16. PLEASE CHANGE THE LABEL ON THE CHART SHOWING | | | COMPLIANCE WITH SECTION 94-442 (G) FLORIDA FRIENDLY | | | LANDSCAPE REQUIREMENTS TO CORRECTLY IDENTIFY IT AS | | | SUCH. | | | | | | 17. PLEASE PROVIDE CALCULATIONS TO SHOW COMPLIANCE WITH | | | SECTION 94-443 (E)(1) REQUIRING AT LEAST 30 PERCENT OF | | | THE LINEAR FEET AROUND THE BUILDING IS PLANTED WITH | | | TREES, SHRUBS OR HEDGES. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
12-08-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
12-08-2016 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
12-08-2016 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2016-12-08 16:54:52 | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: PALM HARBOR MARINA HOTEL Z16110016 | | | DECEMBER 8, 2016 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PLEASE PROVIDE A TREE MITIGATION CHART IDENTIFYING | | | EXISTING TREES ON THE PROPERTY THAT WILL BE REMOVED AND | | | MITIGATION PROVIDED PER SECTION 94-448. | | | | | | 2. PLEASE PROVIDE THE PERCENTAGE OF VEGETATED AREA AND | | | TREE CANOPY REQUIRED AND PROVIDED FOR QUALIFYING PLAZA | | | AREAS PER SECTION 94-444. | | | | | | 3. PLEASE PROVIDE A LANDSCAPE PLAN FOR THE ROOFTOP | | | AMENITY DECK. | | | | | | 4. PLEASE PROVIDE A COLUMN ON THE PLANT LIST SHOWING | | | DROUGHT TOLERANCE LEVELS INDICATED IN WATERWISE, THE | | | SOUTH FLORIDA WATER MANAGEMENT DISTRICT PLANT AND | | | LANDSCAPE PRACTICES GUIDE AS SPECIFIED IN SECTION | | | 94-446(G). PLEASE REVISE AND RECALCULATE TO CONFIRM | | | PERCENTAGES FOR POINTS CLAIMED. | | | | | | 5. PLEASE SHOW THE TOTAL NUMBER OF PARKING SPACES | | | PROVIDED ON THE SITE PLAN DATA CHART AND USE THIS | | | NUMBER FOR THE CALCULATION OF LANDSCAPE AREA REQUIRED | | | PER SECTION 94-443(C)(3). | | | | | | 6. PLEASE DEMONSTRATE COMPLIANCE WITH SECTION 94-443 | | | (C)(4) FOR THE AMOUNT OF LANDSCAPE AREA REQUIRED IN THE | | | LANDSCAPE ISLANDS PROVIDING 4 SQUARE FEET FOR EACH 100 | | | SQUARE FEET OF OTHER PAVED AREAS ADDITIONAL TO PARKING | | | SPACES. | | | | | | 7. PLEASE PROVIDE A LANDSCAPE TERMINAL ISLAND AND | | | REQUIRED SHADE TREE FOR EACH ROW OF PARKING IN ALL | | | TERMINAL ISLANDS IN PARKING AREAS PER SECTION 94-443 | | | (C)(3)A. | | | | | | 8. PLEASE SHOW ALL UTILITIES INCLUDING WATER, SEWER, | | | AND FPL TRANSFORMERS ON THE LANDSCAPE PLAN. ADJUST | | | UTILITY LOCATIONS TO AVOID REQUIRED TREES. | | | | | | 9. PLEASE INCLUDE A ROOT BARRIER DETAIL AND SHOW | | | LOCATIONS OF ROOT BARRIERS TO PROTECT INFRASTRUCTURE | | | AND TREES FROM CONFLICTS. THIS INCLUDES WATER, SEWER, | | | DRAINAGE, SIDEWALKS AND CURBS, AND ANY FIELD STRUCTURES | | | THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 10. PLEASE PROVIDE SCREENING FOR ALL GROUND MOUNTED | | | EQUIPMENT AND UTILITIES. | | | | | | 11. PLEASE PROVIDE DETAILS ON HOW THE DUMPSTER | | | ENCLOSURE WILL FUNCTION AND PROVIDE A COMPLETE HEDGE | | | AROUND THE THREE NON-ACCESS SIDES OF THE | | | DUMPSTER/COMPACTOR ENCLOSURE. | | | | | | 12. PLEASE PROVIDE A BUFFER REQUIREMENTS CHART LISTING | | | THE REQUIRED BUFFER LENGTH CALCULATIONS AND NUMBER OF | | | TREES REQUIRED AND PROVIDED FOR EACH SIDE OF THE | | | PROPERTY AND LABEL THE LOCATIONS OF THE 5 FOOT REQUIRED | | | BUFFERS PER SECTION 94-442(B). | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
01-19-2017 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
01-19-2017 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2017-01-19 08:35:11 | THESE COMMENTS ARE FROM THE REVIEW OF THE THE JANUARY | | | 11, 2017 SUBMITTAL PACKAGE: | | | | | | 1. STORMWATER QUALITY TREATMENT IS NEEDED FOR THE | | | PARKING LOT SOUTH OF THE HOTEL. | | | | | | 2. THE PROPOSED, RELOCATED 18" SANITARY SEWER MAY BE IN | | | CONFLICT WITH THE EXISTING 36" RCP STORM PIPE. | | | | | | 3. INDICATE MILL AND OVERLAY LIMITS WHERE UTILITES ARE | | | BEING CONSTRUCTED IN THE ROAD PER CITY STANDARDS. | | | | | | 4. RECOMMEND CONDUCTING A CONDITION ASSESSMENT OF THE | | | EXISTING CLAY STORM PIPES WITHIN THE SITE. | | | | | | 5. SURVEY AND ENGINEERING PLANS ARE USING DIFFERENT | | | VERTICAL DATUMS. THE CURRENT CITY DATUM IS NATIONAL | | | GEODETIC VERTICAL DATUM OF 1929 (NGVD1929). THE NORTH | | | AMERICAN VERTICAL DATUM OF 1988 (NAVD1988) MAY BE USED | | | FOR THIS SITE PROVIDED A CONVERSION FACTOR BETWEEN | | | NAVD1988 AND NGVD1929 IS PROVIDED. THE VERTICAL DATUM | | | SHOULD BE CONSISTENT ACROSS ALL PLANS/SURVEYS AND | | | LABELED ON THE SHEETS WHERE ELEVATION INFORMATION IS | | | PROVIDED. | | | | | | TRACY L. WARD, P.E. | | | ENGINEERING SERVICES DEPARTMENT | | | [email protected] | | | 561-494-1120 | | | | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
12-14-2016 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
12-14-2016 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
12-14-2016 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2016-12-14 08:49:38 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP:// | | | WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER | | | MITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE | | | AVAILABLE AT | | | HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX?. | | | PLEASE REVIEW THE MAPS AND VERIFY THAT THE NEW MAPS | | | WILL NOT IMPACT THE PROPOSED PROJECT. | | | | | | 2. THE CITY COMMISSION RECENTLY PASSED A RESOLUTION | | | INCREASING THE FREEBOARD REQUIREMENT TO ONE FOOT ABOVE | | | BASE FLOOD ELEVATION FOR STRUCTURES IN A SPECIAL FLOOD | | | HAZARD AREA. | | | | | | 3. EXPLAIN WHAT CPP STORM PIPE IS. | | | | | | 4. SHOW UTILITIES ON THE LANDSCAPE PLANS | | | | | | 5. EXPLAIN HOW STORMWATER TREATMENT WILL BE PROVIDED. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
12-13-2016 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
12-13-2016 |
Time |
10:45 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2016-12-13 10:55:59 | 1. MAINTENANCE AGREEMENT WILL BE REQUIRED FOR | | | IMPROVEMENTS/LANDSCAPING WITHIN RIGHT-OF-WAY. | | | 2. WHO OWNS THE 3 FOOT STRIP BETWEEN FLAGLER DRIVE AND | | | THE LEASE BOUNDARY? IS THIS PARCEL LAND-LOCKED? | | | 3. PROPOSED SANITARY SEWER NEEDS TO BE RELOCATED OFF | | | SIDEWALK. | | | 4. ADD EXISTING AND PROPOSED UTILITIES TO LANDSCAPE | | | PLANS. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
03-14-2017 |
Time |
|
Rev Time |
0.00 |
| Received By |
bcollins |
Date |
03-14-2017 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2017-03-14 13:10:11 | APPROVAL SUBJECT TO CONDITIONS IDENTIFIED BY MS. DANG | | | IN HER PREVIOUS NOTE. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
02-07-2017 |
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2017-02-07 09:16:33 | PALM HARBOR MARINA | | | | | | - CONTACT UYEN DANG @ (561) 494-1087 | | | | | | 1) MILLING AND RESURFACING LIMIT INCLUDES ENTIRE | | | FRONTAGE OF PROPERTY TO THE CENTERLINE OF THE PROPERTY. | | | 2) PAVEMENT RESTORATION TO MEET WPB STANDARDS OF 50? ON | | | EACH SIDE OF TRENCH. | | | 3) PROVIDE SIGNING AND STRIPING PLANS FOR FLAGLER DR. | | | AS PART OF RESTORATION PLAN | | | 4) PROVIDE PHOTOMETRICS | | | 5) CONSTRUCTION ROUTE TO BE ON BANYAN BLVD. NO | | | CONSTRUCTION TRAFFIC ARE TO ENTER THROUGH THE WATER | | | FRONT FROM OKEECHOBEE BLVD. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
02-02-2017 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
02-02-2017 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
01-09-2017 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2017-02-02 16:33:29 | 2ND REVIEW | | | 1. PARTIALLY SATISFIED - PLEASE INCLUDE INT HE PARKING | | | CALCULATION SHEET THE INFORMATION REGARDING THE TOTAL | | | NUMBER OF EXISTING SLIPS, THE REQUIRED SPACES, PLUS THE | | | SQUARE FOOTAGE OF THE COMMERCIAL USES AND THE REQUIRED | | | SPACES. ALSO PROVIDE A COPY OF THE LEGAL DOCUMENT THAT | | | IDENTIFIES 166 SPACES FOR THE MARINA USE WITHIN THE | | | EXISTING PARKING GARAGE. EXISTING PARKING LOT INCLUDES | | | 96 SPACES FOR MARINA USE. PLEASE PROVIDE INFORMATION | | | INDICATING NUMBER OF SLIPS CURRENTLY EXISTING AND | | | APPROVED IF NOT ALL BUILT, REQUIRED PARKING AND | | | LOCATION OF MARINA PARKING ONCE SURFACE LOT IS REMOVED. | | | 2. DONE-SURVEY SHALL INCLUDE THE DIMENSION FROM BACK OF | | | CURB ON FLAGLER DRIVE TO PROPERTY LINE. | | | 3. DONE-PLEASE PROVIDE INFORMATION TO CONFIRM | | | COMPLIANCE WITH THE REQUIREMENT OF ONE TREE EVERY 25 | | | FEET OF STREET FRONTAGE. AS THE FLAGLER DRIVE | | | STREETSCAPE PATTERN IS ROYAL PALMS, THE COMPLIANCE WITH | | | THIS REQUIREMENT SHALL BE TO MAINTAIN THE EXISTING | | | ROYAL PALM PLANTING PATTERN, AND FILL IN THE GAPS WITH | | | NEW PALMS OR REPLACING THOSE IN BAD CONDITION. | | | 4. PARTIALLY SATISFIED. DUMPSTER SHALL BE SCREENED , | | | PROVIDE MINIMUM CLEARANCE FOR TRUCK.- PLEASE PROVIDE | | | ADDITIONAL INFORMATION TO CONFIRM ALL BUILDING | | | EQUIPMENT IS SCREENED FROM ABOVE AND BELOW. | | | 5. PARTIALLY SATISFIED. PLEASE PROVIDE DETAILS FOR THE | | | PROPOSED SCREENING FOR MECHANICAL EQUIPMENT.-PLEASE | | | PROVIDE ADDITIONAL INFORMATION ON THE FINISHED MATERIAL | | | OF ALL BUILDING ROOFS, INCLUDING POOL DECK AND ANY | | | CANOPIES. TAR AND GRAVEL OR BALLAST SHALL NOT BE | | | UTILIZED AS FINISHING MATERIALS. | | | 6. PARTIALLY SATISFIED. PLEASE REMOVE REFERENCE TO | | | URBAN CORE PARKING REQUIREMENTSPLEASE REVISE PARKING | | | DATA TO REFLECT THE PARKING REQUIREMENTS FOR A HOTEL | | | WITHIN A SPECIAL DISTRICT ACCORDING TO TABLE IV-9 IN | | | ARTICLE IV OF THE ZONING CODE. PARKING CALCULATIONS | | | SHALL BE BASED ON NET INTERIOR AREA WHEN REQUIREMENT IS | | | BASED ON SQUARE FOOTAGE. | | | 7. NOT SATISFIED. STRIPING DETAIL IN SHEET A1.1.01 | | | SHALL FOLLOW CITY STANDARDS- ALL PARKING SPACES SHALL | | | BE STRIPED FOLLOWING CITY STANDARDS. | | | 8. NOT SATISFIED. NOTE NOT REMOVED - PROJECT COMPLIES | | | WITH MINIMUM REQUIRED PARKING, PLEASE REMOVE NOTE | | | REGARDING PAYMENT IN LIEU FROM PARKING TABLE. 10% | | | REDUCTION ON PARKING REQUIREMENT IS NOT APPLICABLE TO | | | HOTEL USES, PLEASE REMOVE NOTE FROM TABLE. | | | 9. NOT SATISFIED.-PLEASE PROVIDE DETAIL DRAWINGS FOR | | | THE TWO PARKING AREAS INCLUDING DIMENSIONS FOR PARKING | | | SPACES AND DRIVE AISLES, STRIPING DETAIL, WHEEL STOPS | | | OR CONTINUOUS CURB DETAIL ETC. | | | 10.DONE.-BASED ON THE TOTAL NUMBER OF PARKING SPACES | | | PROVIDED (65), 3 PARKING SPACES FOR THE DISABLED ARE | | | REQUIRED. PLEASE DISCUSS WITH THE BUILDING OFFICIAL ON | | | THE LOCATION OF THE SPACES DUE TO THE FACT THAT THE | | | PROJECT INCLUDES TWO SEPARATE PARKING LOTS (ONE VALET | | | ONLY AND ONE SELF PARKING). | | | 11. PARTIALLY SATISFIED. PLEASE INCLUDE DETAILS ON | | | PROPOSED RACK AND LOCATION.- PLEASE PROVIDE INFORMATION | | | TO CONFIRM COMPLIANCE WITH BICYCLE PARKING | | | REQUIREMENTS. INDICATE NUMBER AND LOCATION. 1/20 SPACES | | | REQUIRED. | | | 12. NOT SATISFIED.- PROPOSED PROJECT DOES NOT MEET THE | | | MINIMUM LOADING REQURIEMENTS SPECIFIED IN TABLEXV-4. A | | | VARIANCE WILL BE REQUIRED TO REDUCE THE NUMBER OF | | | LOADING SPACES. | | | 13. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | | WITH MINIMUM REQUIRED SETBACKS ALONG ALL SIDES. | | | INDICATE DIMENSION FROM BACK OF CURB OR PROPERTY LINES | | | WHEN APPLICABLE. | | | 14. PARTIALLY SATISDIED. PLEASE INCLUDE PL AND SETBACK | | | LINES IN ALL FLOOR PLANS, ELEVATIONS AND SECTIONS.- | | | PLEASE INDICATE PROPERTY LINES IN ALL FLOOR PLANS AND | | | ELEVATIONS. | | | 15. PARTIALLY SATISFIED. INFORMATION SHALL BE PROVIDED | | | ACCORDING TO DEFINITIONS OF OPEN SPACE, PLAZA, | | | LANDSCAPE AREA, BUILDING COVERAGE ETS IN SEC 94-130. | | | PLAZA AREA CANNOT INCLUDE SIDEWALK AREAS-PLEASE INCLUDE | | | TOTAL SQUARE FOOTAGE AND PERCENTAGES ON GRAPHIC | | | INCLUDED IN SHEET A0.0.04 TO ILLUSTRATE COMPLIANCE WITH | | | MINIMUM REQUIRED OPEN SPACE AREA, MINIMUM PLAZA AREA, | | | AND MINIMUM LANDSCAPE AREAS. PLEASE PROVIDE A CADD | | | DRAWING OF THIS SHEET TO ALLOW MEASUREMENTS. | | | 16. DONE.-PLEASE PROVIDE ADDITIONAL DETAIL FOR THE | | | SERVICE AREA, INCLUDING EXACT LOCATION OF DUMPSTER AND | | | ITS SCREENING. | | | 17.NOT SATISFIED. PLEASE PROVIDE DETAILS ON PLAZA. FUEL | | | TANK AREA CANNOT BE COUNTED AS A PLAZA AREA UNLESS | | | IMPROVED FOR PEOPLE TO ENJOY THE SPACE. PLEASE PROVIDE | | | DETAILS ON RETAINING WALL TREATMENT AND HEIGHT TO | | | IDENTIFY THE IMPACT ON THE PLAZA SPACE.- PLEASE PROVIDE | | | INFORMATION TO CONFIRM COMPLIANCE WITH PLAZA | | | REQUIREMENTS IN SEC 94-444. | | | 18. NOT SATISFIED.-PLEASE PROVIDE ADDITIONAL | | | INFORMATION FOR PROPOSED LANDSCAPE AND HARDSCAPE OF THE | | | PROPOSED PLAZA. | | | 19. DONE-PLEASE PROVIDE INFORMATION REGARDING THE USE | | | OF THE 3RD STREET DRIVEWAY, OUTSIDE PROPERTY | | | BOUNDARIES. | | | 20. ELEVATIONS SHALL ACCURATELY REFLECT THE GRADE | | | DIFFERENCE BETWEEN THE HOTEL LOBBY ENTRANCE AND THE | | | FLAGLER DRIVE SIDEWALK AND ROAD, AS WELL AS THE | | | PROMENADE ALONG THE WATERFRONT. | | | 21. PLEASE INDICATE THE PROPERTY LINE AND REQUIRED | | | SETBACK LINES IN ALL ELEVATIONS AND SECTIONS. | | | 22. PLEASE INDICATE PROPOSED LOCATION OF REQUIRED ART | | | IN PUBLIC PLACES. | | | 23.STAFF RECOMMENDS A NEW WINDOW TO BE ADDED ON THE | | | FIRST FLOOR OF THE EXIT STAR FACING FLAGLER DRIVE TO | | | MINIMIZE THE LACK OF ACTIVE USES ALONG FLAGLER DRIVE. | | | 24. PLEASE INCLUDE THE EXISTING CONDITIONS OF THE AREA | | | INMEDIATELY NORTH OF THE PROPERTY LINE WITH THE | | | WATERVIEW RESIDENTIAL BUILDING TO DETERMINE ANY IMPACTS | | | ON EXISING SPACE. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
12-13-2016 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
12-13-2016 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
12-13-2016 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2016-12-14 08:21:37 | 1. EXISTING PARKING LOT INCLUDES 96 SPACES FOR MARINA | | | USE. PLEASE PROVIDE INFORMATION INDICATING NUMBER OF | | | SLIPS CURRENTLY EXISTING AND APPROVED IF NOT ALL BUILT, | | | REQUIRED PARKING AND LOCATION OF MARINA PARKING ONCE | | | SURFACE LOT IS REMOVED. | | | 2. SURVEY SHALL INCLUDE THE DIMENSION FROM BACK OF CURB | | | ON FLAGLER DRIVE TO PROPERTY LINE. | | | 3. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | | WITH THE REQUIREMENT OF ONE TREE EVERY 25 FEET OF | | | STREET FRONTAGE. AS THE FLAGLER DRIVE STREETSCAPE | | | PATTERN IS ROYAL PALMS, THE COMPLIANCE WITH THIS | | | REQUIREMENT SHALL BE TO MAINTAIN THE EXISTING ROYAL | | | PALM PLANTING PATTERN, AND FILL IN THE GAPS WITH NEW | | | PALMS OR REPLACING THOSE IN BAD CONDITION. | | | 4. PLEASE PROVIDE ADDITIONAL INFORMATION TO CONFIRM ALL | | | BUILDING EQUIPMENT IS SCREENED FROM ABOVE AND BELOW. | | | 5. PLEASE PROVIDE ADDITIONAL INFORMATION ON THE | | | FINISHED MATERIAL OF ALL BUILDING ROOFS, INCLUDING POOL | | | DECK AND ANY CANOPIES. TAT, TAR AND GRAVEL OR BALLAST | | | SHALL NOT BE UTILIZED AS FINISHING MATERIALS. | | | 6. PLEASE REVISE PARKING DATA TO REFLECT THE PARKING | | | REQUIREMENTS FOR A HOTEL WITHIN A SPECIAL DISTRICT | | | ACCORDING TO TABLE IV-9 IN ARTICLE IV OF THE ZONING | | | CODE. PARKING CALCULATIONS SHALL BE BASED ON NET | | | INTERIOR AREA WHEN REQUIREMENT IS BASED ON SQUARE | | | FOOTAGE. | | | 7. ALL PARKING SPACES SHALL BE STRIPED FOLLOWING CITY | | | STANDARDS. | | | 8. PROJECT COMPLIES WITH MINIMUM REQUIRED PARKING, | | | PLEASE REMOVE NOTE REGARDING PAYMENT IN LIEU FROM | | | PARKING TABLE. 10% REDUCTION ON PARKING REQUIREMENT IS | | | NOT APPLICABLE TO HOTEL USES, PLEASE REMOVE NOTE FROM | | | TABLE. | | | 9. PLEASE PROVIDE DETAIL DRAWINGS FOR THE TWO PARKING | | | AREAS INCLUDING DIMENSIONS FOR PARKING SPACES AND DRIVE | | | AISLES, STRIPING DETAIL, WHEEL STOPS OR CONTINUOUS CURB | | | DETAIL ETC. | | | 10.BASED ON THE TOTAL NUMBER OF PARKING SPACES PROVIDED | | | (65), 3 PARKING SPACES FOR THE DISABLED ARE REQUIRED. | | | PLEASE DISCUSS WITH THE BUILDING OFFICIAL ON THE | | | LOCATION OF THE SPACES DUE TO THE FACT THAT THE PROJECT | | | INCLUDES TWO SEPARATE PARKING LOTS (ONE VALET ONLY AND | | | ONE SELF PARKING). | | | 11.PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | | WITH BICYCLE PARKING REQUIREMENTS. INDICATE NUMBER AND | | | LOCATION. 1/20 SPACES REQUIRED. | | | 12. PROPOSED PROJECT DOES NOT MEET THE MINIMUM LOADING | | | REQURIEMENTS SPECIFIED IN TABLEXV-4. A VARIANCE WILL BE | | | REQUIRED TO REDUCE THE NUMBER OF LOADING SPACES. | | | 13. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | | WITH MINIMUM REQUIRED SETBACKS ALONG ALL SIDES. | | | INDICATE DIMENSION FROM BACK OF CURB OR PROPERTY LINES | | | WHEN APPLICABLE. | | | 14. PLEASE INDICATE PROPERTY LINES IN ALL FLOOR PLANS | | | AND ELEVATIONS. | | | 15. PLEASE INCLUDE TOTAL SQUARE FOOTAGE AND PERCENTAGES | | | ON GRAPHIC INCLUDED IN SHEET A0.0.04 TO ILLUSTRATE | | | COMPLIANCE WITH MINIMUM REQUIRED OPEN SPACE AREA, | | | MINIMUM PLAZA AREA, AND MINIMUM LANDSCAPE AREAS. PLEASE | | | PROVIDE A CADD DRAWING OF THIS SHEET TO ALLOW | | | MEASUREMENTS. | | | 16. PLEASE PROVIDE ADDITIONAL DETAIL FOR THE SERVICE | | | AREA, INCLUDING EXACT LOCATION OF DUMPSTER AND ITS | | | SCREENING. | | | 17. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | | WITH PLAZA REQUIREMENTS IN SEC 94-444. | | | 18. PLEASE PROVIDE ADDITIONAL INFORMATION FOR PROPOSED | | | LANDSCAPE AND HARDSCAPE OF THE PROPOSED PLAZA. | | | 19. PLEASE PROVIDE INFORMATION REGARDING THE USE OF THE | | | 3RD STREET DRIVEWAY, OUTSIDE PROPERTY BOUNDARIES. | | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | | APONTE AT 561-822-1439 | | | |
|
|
| |