Plan Review Details - Project Z16080012
| Plan Review Stops For Project Z16080012 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
04-20-2017 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
04-20-2017 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
04-20-2017 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2017-04-20 10:41:17 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES | | | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO | | | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL | | | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE | | | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED | | | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR | | | OTHER APPROVED METHODS. | | | | | | 3. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
01-11-2017 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
01-11-2017 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
01-11-2017 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2017-01-11 11:46:12 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. THE PROPOSED BUILDING WILL BE IN FLOOD ZONE. | | | CORRECTION OF THE FOLLOWING TYPOGRAPICAL ERROR WILL BE | | | CHECKED WHEN SUBMITTED FOR PERMIT. SHEET A114 STATES | | | THE ELEVATION OF THE MECHANICAL ROOMS AS 6'-9" NGVD. | | | THAT APPEARS TO BE A TYPOGRAPHICAL ERROR BECAUSE, | | | ACCORDING TO THE COMMENT RESPONSE NARRATIVE, THIS | | | SHOULD BE 9'-6" NGVD. THE ELEVATION OF THE FIRST FLOOR | | | OF THE BUILDING AND ALL ASSOCIATED MECHANICAL EQUIPMENT | | | (CHILLERS, GENERATORS ETC.) SHALL BE 12 INCHES | | | (FREEBOARD) ABOVE THE BASE FLOOD ELEVATION. | | | | | | 3. SHEET A114, GROUND FLOOR PLAN, DOES NOT SHOW A SAFE | | | PEDESTRIAN ROUTE FROM THE NORTH-WEST OR THE SOUTH-WEST | | | STAIR TO THE SIDEWALK. | | | | | | 4. SHEET A115, LEVEL 2 PLAN, THE EXIT DOOR FROM THE | | | SOUTH-WEST SHOULD SWING OUTWARD. | | | | | | 5. WHEN SUBMITTED FOR PERMIT, THE PLANS SHALL CLEARLY | | | SHOW THE ACCESSIBLE WALKWAY FROM THE SIDEWALK TO THE | | | BUILDING EMTRANCE. IF THAT IS TO BE BY MEANS OF THE | | | MEANDERING WALKWAY, SHOWN ON SHEET A115, LEVEL 2 PLAN, | | | LEADING FROM ARKONA COURT UP THE LANDSCAPE BERM TO THE | | | ARRIVAL COURT AT THE NORTH-WEST CORNER OF THE BUILDING, | | | IT SHALL BE CLEARLY SHOWN TO HAVE A SLOPE OF 1 IN 20 OR | | | BETTER. ANY PART OF AN ACCESSIBLE ROUTE WITH A SLOPE | | | GREATER THAN 1:20 SHALL BE CONSIDERED A RAMP AND SHALL | | | COMPLY WITH SECTION 405 OF FLORIDA ACCESSIBILITY CODE. | | | | | | 6. SHEET A122, LEVEL 25. THERE APPEARS TO BE A DRAFTING | | | ERROR. WHEN SUBMITTED FOR PERMIT THE CORRIDOR LEADING | | | TO THE EAST STAIR SHALL BE CLEARLY SHOWN WITHOUT A WALL | | | ACROSS THE CORRIDOR. AS CURRENTLY SHOWN, THE PENTHOUSE | | | APPEARS TO HAVE ACCESS TO ONLY THE WEST STAIR. THERE IS | | | CURRENTLY NO EXIT PATH SHOWN TO ACCESS THE EAST STAIR | | | BECAUSE A WALL IS SHOWN OPPOSITE THE ELEVATOR 1 LANDING | | | DOOR. A MINIMUM OF TWO SEPARATE EXITS IS REQUIRED. | | | | | | 7. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES | | | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO | | | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL | | | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE | | | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED | | | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR | | | OTHER APPROVED METHODS. | | | | | | 8. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
09-14-2016 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
09-14-2016 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
09-14-2016 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2016-09-14 11:01:08 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. THE PROPOSED BUILDING WILL BE IN FLOOD ZONE. THE | | | ELEVATION OF THE FIRST FLOOR OF THE BUILDING AND ALL | | | ASSOCIATED MECHANICAL EQUIPMENT (CHILLERS, GENERATORS | | | ETC.) SHALL BE 12 INCHES (FREEBOARD) ABOVE THE BASE | | | FLOOD ELEVATION. | | | | | | 3. SIX ACCESSIBLE PARKING SPACES ARE SHOWN ON SHEET | | | A113, GROUND FLOOR PLAN, BUT FOUR OF THEM DO NOT HAVE | | | ACCESSIBLE ACCESS AISLE. ACCESSIBLE PARKING SPACE | | | ACCESS AISLES SHALL BE LOCATED SO THAT THE USER IS NOT | | | COMPELLED TO WALK OR WHEEL BEHIND ANOTHER PARKED | | | VEHICLE OR IN THE TRAVEL LANE. THE ACCESS AISLES SHALL | | | ALSO COMPLY WITH THE OTHER PROVISIONS OF SECTION OF | | | 502.3 OF FLORIDA ACCESSIBILITY CODE. | | | | | | 4. PER SECTION 208.2.4 OF FLORIDA ACCESSIBILITY CODE, | | | ONE IN EVERY SIX ACCESSIBLE SPACES (AT LEAST ONE) IN A | | | PARKING STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND | | | DESIGNED IN ACCORDANCE WITH SECTION OF 502 OF FLORIDA | | | ACCESSIBILITY CODE (VERTICAL CLEARANCE NOT LESS THAN 98 | | | INCHES AT SPACE AND VEHICULAR ACCESS ROUTE) | | | | | | 5. SHEET A114, LEVEL 2 ? AMENITIES PLAN. NO EXIT DOOR | | | IS SHOWN TO ACCESS THE WEST STAIR. | | | | | | 6. SHEET A115, LEVEL 3. INDOOR AMENITIES SPACE IS | | | LIKELY TO BE AN ASSEMBLY OCCUPANCY, BUT ONLY ONE EXIT | | | IS SHOWN. THE ONLY ACCESS TO THE WEST STAIR TAKES | | | OCCUPANTS PAST THE EAST STAIR, SO ONE FIRE EVENT COULD | | | ENDER BOTH STAIRS UNAVAILABLE. A MINIMUM OF TWO | | | SEPARATE EXITS IS REQUIRED. | | | | | | 7. SHEET A116, LEVEL 4. WHAT IS THE PURPOSE OF THE | | | GREAT LOUNGE? IS THAT SPACE AN ASSEMBLY OCCUPANCY? ONLY | | | ONE EXIT IS SHOWN, BECAUSE THE ONLY ACCESS TO THE WEST | | | STAIR TAKES OCCUPANTS PAST THE EAST STAIR, SO ONE FIRE | | | EVENT COULD ENDER BOTH STAIRS UNAVAILABLE. A MINIMUM OF | | | TWO SEPARATE EXITS IS REQUIRED IF IT IS AN ASSEMBLY | | | OCCUPANCY. | | | | | | 8. SHEET A121, LEVEL 26. THE PENTHOUSE APPEARS TO HAVE | | | ACCESS TO ONLY THE WEST STAIR. THERE IS NO EXIT PATH | | | SHOWN TO ACCESS THE EAST STAIR. A MINIMUM OF TWO | | | SEPARATE EXITS IS REQUIRED. | | | | | | 9. SHEET A122, LEVEL 27. THE PENTHOUSE APPEARS TO HAVE | | | ACCESS TO ONLY THE WEST STAIR. THERE IS NO EXIT PATH | | | SHOWN TO ACCESS THE EAST STAIR. A MINIMUM OF TWO | | | SEPARATE EXITS IS REQUIRED. | | | | | | 10. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL | | | SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS | | | WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND | | | OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA | | | BUILDING CODE | | | | | | 11. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH | | | ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND | | | OPENING PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 OF | | | THE FLORIDA BUILDING CODE SHALL BE VERIFIED. | | | | | | 12. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE | | | DOES NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL | | | OPENINGS TO MEET THE DEFINITION OF AN OPEN PARKING | | | GARAGE, IT WILL BE CONSIDERED AN ENCLOSED PARKING | | | GARAGE AND MUST HAVE EXHAUST SYSTEMS. THE EXHAUST | | | SYSTEMS SHALL BE DESIGNED TO MINIMIZE NOISE LEVELS | | | USING INLINE FAN SILENCERS OR OTHER APPROVED METHODS. | | | | | | 13. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 14. THIS PROJECT WILL BE SUBJECT TO ART IN PUBLIC | | | PLACES (AIPP) ASSESSMENT. FOR ADVICE ON THE PROVISION | | | OF PUBLIC ARTWORK IN LIEU OF THE AIPP ASSESSMENT, | | | CONTACT SYBILLE WELTER, ART IN PUBLIC PLACES | | | COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
P |
Date |
03-28-2017 |
|
|
Cont ID |
|
| Sent By |
mkhan |
Date |
03-28-2017 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
mkhan |
Date |
03-28-2017 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2017-03-28 15:54:27 | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | | | | PROJECT NAME: GREAT GULF - 1515 S. FLAGLER DR. - | | | Z16080012 (CASE #: PB 1559J) | | | | | | RESUBMITTAL REVIEW RESPONSE/STATUS: PASSED WITH | | | CONDITION | | | | | | DATE: MARCH 28, 2017 | | | | | | AFTER A REVIEWING THE REVISED PLANS AND THE RESPONSE TO | | | THE PREVIOUS PPRC COMMENTS (RECEIVED ON 3/22/2017), IT | | | APPEARS THAT SOME OF THE COMMENTS HAVE BEEN SATISFIED | | | AND SOME ARE ACKNOWLEDGED THE ACKNOWLEDGED COMMENTS AND | | | A NEW COMMENT SHOWN BELOW ARE EXPECTED TO BE ADDRESSED | | | DURING 'ENGINEERING DEVELOPMENT APPLICATION' PHASE | | | PRIOR TO ISSUANCE OF CONSTRUCTION AUTHORIZATION | | | INCLUDING BUILDING PERMITS AND ENGINEERING DEVELOPMENT | | | APPROVAL: | | | | | | 1. IN THE FINAL PLANS, SHOW CONFLICT INFORMATION | | | (BOTTOM AND TOP OF CROSSING PIPES) AT THE CONFLICT | | | POINTS OF THE PROPOSED WATER AND SANITARY SEWER PIPES | | | WITH THE EXISTING AND PROPOSED STORM DRAINS JUST TO THE | | | NORTH OF THE BUILDING AND INSIDE THE PROPERTY; | | | | | | 2. IN THE REVISED PLANS PROPOSED MANHOLE THAT IS CALLED | | | OUT AS CITY'S 'POINT-OF-SERVICE' IS SHOWN TO BE INSIDE | | | THE PRIVATE PROPERTY. CITY'S 'POINT-OF-SERVICE' MANHOLE | | | SHALL BE WITHIN THE CITY'S RIGHT-OF-WAY. PLEASE CORRECT | | | IT IN THE FINAL PLANS; | | | | | | 3. 'FIRE POINT-OF-SERVICE' SHALL BE, PER 2016 NFPA 24, | | | FROM THE CONNECTION POINT OF THE PROPOSED FIRE LINE TO | | | THE EXISTING WATER MAIN LOCATED WITHIN THE CITY'S | | | RIGHT-OF-WAY I.E. WHERE TAPPING SLEEVE AND VALVES IS | | | SHOWN TO BE FOR BOTH SOUTH FLAGLER DR. AND ARKONA CT. | | | PLEASE REVISE AND SHOW ACCORDINGLY ON THE FINAL PLANS; | | | | | | 4. AS OF DECEMBER 20, 2015 THE CITY OF WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED MAKING | | | KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD FREE." IN | | | THE FINAL WATER AND SEWER PLANS, INCLUDE A NOTE STATING | | | THAT. FOR MORE INFORMATION REFER TO THE LINK BELOW: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | | | | 5. RIGHT-OF-WAY PERMIT AND SUBMITTAL OF MAINTENANCE OF | | | TRAFFIC (MOT) FOR WORK WITHIN THE CITY'S RIGHT-OF-WAY | | | WILL BE REQUIRED PRIOR TO CONSTRUCTION BEGINS FOR THIS | | | DEVELOPMENT. | | | | | | MOSTAQUE KHAN, P.E. | | | LAND DEVELOPMENT ENGINEER | | | [email protected] | | | 561-494-1124 (OFFICE) | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
01-10-2017 |
|
|
Cont ID |
|
| Sent By |
mkhan |
Date |
01-10-2017 |
Time |
09:27 |
Rev Time |
2.00 |
| Received By |
mkhan |
Date |
01-10-2017 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2017-01-10 09:33:05 | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | | | | PROJECT NAME: 1515 S. FLAGLER DR. - THE MODERN - | | | Z16080012 | | | DATE: JANUARY 10, 2017 | | | | | | STATUS: PASSED WITH PROVISO (STATED BELOW): | | | | | | AFTER A REVIEWING THE REVISED PLANS AND THE RESPONSES | | | TO THE PPRC COMMENTS (RECEIVED ON 12/21/2016), IT | | | APPEARS THAT SOME OF THE PREVIOUS COMMENTS HAVE BEEN | | | ACKNOWLEDGED. HOWEVER, THESE ACKNOWLEDGED COMMENTS | | | ALONG WITH THE FOLLOWING ITEMS ARE EXPECTED TO BE | | | ADDRESSED DURING 'ENGINEERING DEVELOPMENT APPLICATION' | | | PHASE PRIOR TO ISSUANCE OF CONSTRUCTION AUTHORIZATION | | | INCLUDING BUILDING PERMITS AND ENGINEERING DEVELOPMENT | | | APPROVAL: | | | | | | 5. REVISED 'UTILITY PLAN - C6.00' SHOWS A WATER | | | CONNECTION COMING INSIDE THE PROPERTY FROM SOUTH | | | FLAGLER DRIVE (NEAR THE THREE EXISTING WATER VALVES AND | | | JUST NORTH OF THE PROPOSED 'POINT OF WATER SERVICE'). | | | IT NEEDS TO BE CUT AND CAPPED AND CALLED OUT SO IN THE | | | PLAN, IF NOT USED FOR THE DEVELOPMENT; | | | 6. SIGNED & SEALED ENGINEER/MEP WATER AND SEWER DEMAND | | | CALCULATIONS (AVERAGE AND PEAK) FOR METER SIZING | | | SELECTION AND SERVICE SIZING NEED TO BE SUBMITTED PRIOR | | | TO 'BUILDING PERMIT'. ALSO NEEDED IS CALCULATION FOR | | | FIRE FLOW DEMAND; | | | 7. REVISED 'UTILITY PLAN' DOES NOT CONTAIN FIRE HYDRANT | | | FLOW TEST DATA FROM EXISTING FIRE HYDRANT USED FOR | | | DESIGN. WAS IT SUBMITTED IN A SEPARATE DOCUMENT? PLEASE | | | SUBMIT THE INFORMATION WITH THE DETAIL ENGINEEING PLANS | | | DURING SUBMISSION OF 'ENGINEER DEVELOPMENT APPLICATION' | | | PHASE. | | | 10. PREVIOUS COMMENT OF: 'CITY'S RECORD INFORMATION | | | SHOWS THAT FROM AN EXISTING SAN MH AT THE OLIVE AVENUE | | | AND CRANENEST WAY INTERSECTION, THERE IS AN 8-INCH | | | SANITARY SEWER THAT RUNS EAST FOR APPROXIMATELY 320 LF | | | AND TERMINATE ON THE SUBJECT PROPERTY. THERE IS NEED TO | | | TELEVISE THIS MAIN AND CALL OUT THE PIPE SECTION WITHIN | | | THE R/W TO BE REMOVED IF NOT IN USE'. SUBMITTED SURVEY | | | AND REVISED 'UTILITY PLAN' DOES NOT SHOW THIS LINE. IT | | | HAS BEEN 'ACKNOWLEDGED' IN THE RESPONSE BUT NO PROPOSED | | | PLAN IS SHOWN ON THE PLAN. PLEASE ADDRESS THIS COMMENT | | | AS ADVISED; | | | | | | THE FOLLOWING NEW COMMENT MUST BE ALSO ADDRESSED PRIOR | | | TO ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL: | | | | | | 12. EXISTING MANHOLE AT THE INTERSECTION OF SOUTH | | | FLAGLER DRIVE AND ARKONA CT. WHERE THE PROPOSED | | | SANITARY SEWER IS CONNECTED SHALL BE REHABILITATED PER | | | CITY STANDARD; | | | 13. AUTOTURN ANALYSIS IS NOT INCLUDED IN THE PLANS; | | | 14. PAVEMENT RESTORATION SHOWN ON THE REVISED 'UTILITY | | | PLAN - C6.00' SHALL BE PER THE DETAIL P-4 I.E. 'FULL | | | LANE WIDTH OF TRAVEL LANE(S) ENCROACHED BY THE TRENCH | | | AREA, INCLUDING A TRANSITION AREA OF 50 FEET ON EACH | | | SIDE OF THE TRENCH'. PLEASE REVISE THE PAVEMENT | | | RESTORATION HATCH AREA ACCORDINGLY FOR ALL WATER AND | | | SEWER CONNECTION WORK; | | | 15. INCLUDE THE CITY'S STANDARD DETAIL FOR PARKING | | | STALL STRIPING DETAIL; | | | | | | MOSTAQUE KHAN, P.E. | | | LAND DEVELOPMENT ENGINEER | | | [email protected] | | | 561-494-1124 (OFFICE) | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
01-10-2017 |
|
|
Cont ID |
|
| Sent By |
mkhan |
Date |
09-14-2016 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
mkhan |
Date |
09-14-2016 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2017-01-10 09:25:15 | SEE COMMENTS IN UTILITIES, STORMWATER AND TRAFFIC | | | ENGINEERING. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
03-29-2017 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
03-29-2017 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
03-29-2017 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2017-03-29 13:26:32 | 3RD REVIEW RESPONSE | | | | | | AFTER A REVIEW OF THE PPRC RESPONSE DATED MARCH 20, | | | 2017, FROM STANTEC, TO ERIC SCHNEIDER, PRINCIPAL | | | PLANNER, THE PREVIOUSLY SUBMITTED FIRE PREVENTION | | | BUREAU COMMENTS HAVE BEEN ADDRESSED. | | | | | | THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES | | | NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
01-06-2017 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
01-06-2017 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
01-06-2017 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2017-01-06 16:52:01 | THE PREVIOUS COMMNETS FROM THE BUREAU OF FIRE | | | PREVENTION WERE ADDRESSED UNDER COMMNET REVIEW. | | | | | | THE FOLLOWING ADDITIONAL COMMENTS WERE SUBMITTED BY | | | PETER LEDUC, FIRE MARSHAL, BUREAU OF FIRE PREVENTION, | | | WEST PALM BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | | | | | | | 1) THE LOCATION OF THE FIRE HYDRANT AND FDC ON ARKONA | | | CT WOULD BE BETTER LOCATED CLOSER TO THE ENTRANCE RAMP | | | AND ACCESS TO THE FIRE COMMAND ROOM AREA. | | | | | | | | | | | | 2) THE LOCATION OF THE FIRE PUMP ROOM WOULD BE BETTER | | | LOCATED ON A OUTSIDE WALL WITH EXTERIOR ACCESS AND NEXT | | | TO THE FIRE COMMAND ROOM FOR EFFECTIVE AND EFFICIENT | | | ACCESS. | | | | | | | | | | | | 3) PLEASE CONFIRM THAT THERE IS ACCESS TO THE BUILDING | | | FROM FLAGER DR AT THE LOCATION OF THE FDC AND FIRE | | | HYDRANT. | | | | | | | | | | | | 4) PLEASE ENSURE THERE IS CODE COMPLIANT WALL | | | SEPARATION/RATING SURROUNDING THE BOLIER ROOM MEETING | | | NFPA 85 WERE APPLICABLE. | | | | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
09-06-2016 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
09-06-2016 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
09-06-2016 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2016-09-06 16:46:55 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | | | | 6. ALL PARKING STRUCTURES SHALL COMPLY WITH NFPA 88A, | | | PARKING STRUCTURES AND NFPA 101, THE LIFE SAFETY CODE, | | | INCLUDING MORE SPECIFICALLY, CHAPTER 42 STORAGE | | | OCCUPANCIES (PARKING STRUCTURES) | | | | | | | | | 7. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA | | | 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS | | | STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE | | | BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE | | | BEING CONSTRUCTED. SEPARATE SHOP DRAWINGS, ARE REQUIRED | | | TO BE SUBMITTED, REVIEWED AND APPROVED BY THE FIRE | | | PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | | | | | HIGH RISES SHALL HAVE TWO SEPARATE SOURCES OF WATER | | | SUPPLY.THIS APPEARS TO BE PROPOSED, PLEASE CONFIRM. | | | | | | 18.3 WATER SUPPLIES. | | | 18.3.1* AN APPROVED WATER SUPPLY CAPABLE OF SUPPLYING | | | THE REQUIRED FIRE FLOW FOR FIRE PROTECTION SHALL BE | | | PROVIDED TO ALL PREMISES UPON WHICH FACILITIES, | | | BUILDINGS, OR PORTIONS OF BUILDINGS ARE HEREAFTER | | | CONSTRUCTED OR MOVED INTO THE JURISDICTION. | | | THE APPROVED WATER SUPPLY SHALL BE IN ACCORDANCE WITH | | | SECTION 18.4. | | | | | | PER NFPA 14 SECTION 7.12.2, HIGH-RISE BUILDINGS SHALL | | | HAVE AT LEAST TWO REMOTELY LOCATED FIRE DEPARTMENT | | | CONNECTIONS FOR EACH ZONE. THIS APPEARS TO BE PROPOSED, | | | PLEASE CONFIRM. | | | | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | FOR THE PROPOSED FIRE PUMP(S) , WHAT IS(ARE) THE | | | PRIMARY AND SECONDARY POWER SOURCES? | | | | | | | | | 8. A CLASS ?A? NFPA 72 COMPLIANT MONITORED FIRE ALARM | | | SYSTEM IS REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP | | | DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED AND | | | APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY | | | INSTALLATION. | | | | | | | | | | | | 9. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM. | | | | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER?S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | | | | 11. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | ALL NEW FIRE HYDRANTS AND FDC'S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | THE PROPOSED LOCATIONS ARE ACCEPTABLE. ANY CHANGES | | | SHALL BE COORDINATED THROUGH THE BUREAU OF FIRE | | | PREVENTION. | | | | | | | | | 12. COMMAND ROOM | | | | | | THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | A. SHALL BE A MINIMUM OF 200 FT SQUARED WITH A MINIMUM | | | DIMENSION OF 10 FT. | | | B. THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | C. A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | D. SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS AND THE LOCATION | | | OF FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS | | | E. A WORK TABLE. | | | F. IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | G. THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | H. ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION OF | | | THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | I. STATUS INDICATORS AND CONTROLS FOR AIR DISTRIBUTION | | | SYSTEMS. | | | J. CONTROLS FOR UNLOCKING STAIRWAY DOORS SIMULTANEOUSLY | | | K. SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | L. EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | M. FIRE PUMP STATUS INDICATORS | | | N. GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | O. PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | P. CONTROLS REQUIRED FOR SMOKE CONTROL | | | Q. ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1. | | | R. ELEVATOR EMERGENCY OR STANDBY POWER SELECTOR | | | SWITCH(ES), WHERE EMERGENCY OR STANDBY POWER IS | | | PROVIDED | | | | | | | | | 13. RADIO | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | MAINTAIN A MINIMUM RADIO SIGNAL STRENGTH OF 102.0 DBM | | | FOR THE RADIO SYSTEM USED BY WEST PALM BEACH FIRE | | | RESCUE. IF THE MINIMUM CANNOT BE MAINTAINED, A | | | BI-DIRECTIONAL AMPLIFIED SYSTEM SHALL BE INSTALLED WITH | | | A MINIMUM 2-HOUR RUN TIME BATTERY BACK-UP. | | | | | | | | | 14. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | | BUILDING. | | | | | | ANY GATES SHALL BE PROVIDED WITH KNOX KEY ACCESS LOCKS, | | | PADLOCKS AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS. | | | | | | | | | 15. THE SMOKE CONTROL SYSTEM SHALL COMPLY WITH NFPA | | | 101, CHAPTER 9, BUILDING SERVICE AND FIRE PROTECTION | | | EQUIPMENT, INCLUDING: | | | | | | THE SMOKE CONTROL SYSTEMS SHALL BE INSTALLED, | | | INSPECTED, TESTED, AND MAINTAINED IN ACCORDANCE WITH | | | NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS; NFPA 204, | | | STANDARD FOR SMOKE AND HEAT VENTING; OR NATIONALLY | | | RECOGNIZED STANDARDS, ENGINEERING GUIDES, OR | | | RECOMMENDED PRACTICES, AS APPROVED BY THE AUTHORITY | | | HAVING JURISDICTION. | | | | | | THE ENGINEER OF RECORD SHALL CLEARLY IDENTIFY THE | | | INTENT OF THE SYSTEM, THE DESIGN METHOD USED, THE | | | APPROPRIATENESS OF THE METHOD USED, AND THE REQUIRED | | | MEANS OF INSPECTING, TESTING, AND MAINTAINING THE | | | SYSTEM. | | | | | | ACCEPTANCE TESTING SHALL BE PERFORMED BY A SPECIAL | | | INSPECTOR IN ACCORDANCE WITH SECTION 9.9 AND AS WELL AS | | | A CITY FIRE INSPECTOR(S). | | | | | | | | | 16. FLOORS 26TH $ 27TH INDICATE A SINGLE EXIT FROM THE | | | PH UNIT(S). PER NFPA 101, CHAPTER 30,NEW APARTMENT | | | BUILDINGS, TWO EXITS ARE REQUIRED. | | | | | | 30.2.4 NUMBER OF MEANS OF EGRESS. | | | 30.2.4.1 THE NUMBER OF MEANS OF EGRESS SHALL COMPLY | | | WITH SECTION 7.4. | | | 30.2.4.2 THE MINIMUM NUMBER OF EXITS SHALL COMPLY WITH | | | 30.2.4.3, 30.2.4.4, OR 30.2.4.6. | | | 30.2.4.3 EVERY DWELLING UNIT SHALL HAVE ACCESS TO AT | | | LEAST TWO SEPARATE EXITS REMOTELY LOCATED FROM EACH | | | OTHER AS REQUIRED BY 7.5.1. | | | 30.2.4.4 DWELLING UNITS SHALL BE PERMITTED TO HAVE | | | ACCESS TO A SINGLE EXIT, PROVIDED THAT ONE OF THE | | | FOLLOWING CONDITIONS IS MET: | | | (1) THE DWELLING UNIT HAS AN EXIT DOOR OPENING DIRECTLY | | | TO THE STREET OR YARD AT THE FINISHED GROUND LEVEL. | | | (2) THE DWELLING UNIT HAS DIRECT ACCESS TO AN OUTSIDE | | | STAIR THAT COMPLIES WITH 7.2.2 AND SERVES A MAXIMUM OF | | | TWO UNITS, BOTH OF WHICH ARE LOCATED ON THE SAME STORY. | | | (3) THE DWELLING UNIT HAS DIRECT ACCESS TO AN INTERIOR | | | STAIR THAT SERVES ONLY THAT UNIT AND IS SEPARATED FROM | | | ALL OTHER PORTIONS OF THE BUILDING BY FIRE BARRIERS | | | HAVING A MINIMUM 1-HOUR FIRE RESISTANCE RATING, WITH NO | | | OPENING THEREIN. | | | | | | THE PROPOSED 26TH & 27TH FLOOR LAYOUT EXIT STRATEGY | | | DOES NOT MEET THIS REQUIREMENT. PLEASE REVIEW, CORRECT | | | OR JUSTIFY CODE COMPLIANCE. | | | | | | | | | 17. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | | | | 18. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
04-13-2017 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
04-13-2017 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
04-13-2017 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2017-04-13 16:16:47 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: THE MODERN Z16080012 | | | APRIL 13, 2017 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PLEASE PROVIDE A SITE DATA CHART ON THE | | | LANDSCAPE PLAN TO REFLECT THE REQUIRED, APPROVED, AND | | | PROVIDED OPEN SPACE AND LANDSCAPE AREA. | | | | | | 2. SATISFIED. PLEASE PROVIDE CALCULATIONS TO SHOW THE | | | LANDSCAPING AROUND THE STRUCTURE MEETS THE 40% | | | REQUIREMENT FOR TREES, SHRUBS OR HEDGES PER SECTION | | | 94-443 (E)(1). | | | | | | 3. SATISFIED. PLEASE PROVIDE THE REQUIRED TREES WITHIN | | | THE WEST BUFFER, SPACED AS REQUIRED MEETING THE INTENT | | | OF THE ORIGINAL APPROVAL, ALSO AT THE SOUTHEAST CORNER | | | OF THE PROPERTY. | | | | | | 4. SATISFIED. PLEASE PROVIDE A SITE DATA CHART ON THE | | | LANDSCAPE PLAN TO REFLECT THE REQUIRED, APPROVED, AND | | | PROVIDED NUMBER OF TREES, FLOWERING TREES AND SHRUBS | | | BASED ON THE REQUIRED OPEN SPACE. | | | | | | 5. SATISFIED. PLEASE PROVIDE A CHART SHOWING PREVIOUSLY | | | APPROVED AND PROPOSED CALCULATIONS FOR THE BUFFER | | | INTERRUPTIONS THAT REQUIRED A WAIVER. | | | | | | 6. SATISFIED. PLEASE PROVIDE LOCATIONS OF LIGHTING ON | | | THE LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING. | | | | | | 7. SATISFIED. PLEASE SHOW LOCATIONS OF WATER AND SEWER | | | LINES THAT SERVICE THE BUILDING, LOCATIONS OF ABOVE | | | GROUND VALVES, AND LOCATION OF DRAINAGE STRUCTURES ON | | | THE LANDSCAPE PLAN AND RESOLVE CONFLICTS WITH | | | LANDSCAPING. | | | THE LANDSCAPE PLANS CAN BE ENLARGED TO INCORPORATE THE | | | UTILITY LOCATIONS AND TREE LOCATIONS ADJUSTED TO AVOID | | | CONFLICTS. | | | | | | 8. SATISFIED. PLEASE INDICATE THE LOCATION OF THE 10 | | | FOOT LANDSCAPE BUFFER ALONG ARKONA COURT AND SOUTH | | | FLAGLER DRIVE REQUIRED PER SECTION 94-443(D). | | | | | | 9. SATISFIED. PLEASE PROVIDE THE DROUGHT TOLERANCE | | | LEVEL FOR EACH PLANT SPECIES ON THE PLANT LIST, TO SHOW | | | COMPLIANCE WITH SECTION 94-442(G) FLORIDA FRIENDLY | | | LANDSCAPING REQUIREMENTS. PLEASE LABEL THE SECTION IN | | | THE CHART AS SUCH. ADDING A COLUMN IDENTIFYING NATIVE | | | PLANTS IS ALSO SUGGESTED. | | | | | | 10. SATISFIED. PLEASE PROVIDE SCREENING FOR ALL GROUND | | | MOUNTED EQUIPMENT AND UTILITIES. | | | PROVIDE A SCREENING HEDGE FOR WATER VALVES. | | | | | | 11. SATISFIED. PLEASE PROVIDE A ROOT BARRIER DETAIL AND | | | SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT | | | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES | | | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY | | | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. | | | MORE DETAIL IS NEEDED ESPECIALLY FOR DRAINAGE LINES. | | | | | | 12. SATISFIED. PLEASE REVISE THE FLORIDA FRIENDLY | | | LANDSCAPE CHART PER SECTION 94-446 (G) AND PROVIDE | | | DOCUMENTATION FOR THE TYPE OF LANDSCAPE IRRIGATION | | | MOISTURE SENSOR OTHER THAN A RAIN SWITCH TO BE | | | PROVIDED, AND AN IRRIGATION PLAN INDICTING THE | | | LOCATIONS OF LOW, MODERATE AND HIGH WATER USE ZONES. | | | | | | 13. SATISFIED. PLEASE PROVIDE A NARRATIVE TO SHOW HOW | | | THE PLAN COMPLIES WITH THE REQUIREMENTS OF SECTION | | | 94-442 (E) SITE DESIGN FLEXIBILITY AS CLAIMED ON SHEET | | | L000.1. | | | ADDITIONAL COMMENTS 1/10/17: | | | 14. SATISFIED. PLEASE PROVIDE TYPICAL CROSS SECTIONS OF | | | THE LANDSCAPE BUFFER AREAS FOR EACH OF THE FOUR SIDES | | | OF THE BUILDING TO DEMONSTRATE HOW THE LANDSCAPING AND | | | TREES WILL BE PLACED WITHIN THE ENGINEERING OF SLOPES | | | AND ELEVATIONS. | | | | | | 15. SATISFIED. PLEASE REMOVE REFERENCE TO STONE MULCH | | | OVER WEED FABRIC FOR THE WATER VALVE AREA AT THE | | | SOUTHEAST CORNER OF THE SITE. ALL AREAS MUST BE | | | LANDSCAPED WITH GRASS OR GROUNDCOVER AND HAVE A | | | SCREENING HEDGE. | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
01-10-2017 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-10-2017 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-10-2017 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2017-01-10 11:16:23 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: THE MODERN Z16080012 | | | JANUARY 10, 2016 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PLEASE PROVIDE A SITE DATA CHART ON THE | | | LANDSCAPE PLAN TO REFLECT THE REQUIRED, APPROVED, AND | | | PROVIDED OPEN SPACE AND LANDSCAPE AREA. | | | | | | 2. SATISFIED. PLEASE PROVIDE CALCULATIONS TO SHOW THE | | | LANDSCAPING AROUND THE STRUCTURE MEETS THE 40% | | | REQUIREMENT FOR TREES, SHRUBS OR HEDGES PER SECTION | | | 94-443 (E)(1). | | | | | | 3. SATISFIED. PLEASE PROVIDE THE REQUIRED TREES WITHIN | | | THE WEST BUFFER, SPACED AS REQUIRED MEETING THE INTENT | | | OF THE ORIGINAL APPROVAL, ALSO AT THE SOUTHEAST CORNER | | | OF THE PROPERTY. | | | | | | 4. SATISFIED. PLEASE PROVIDE A SITE DATA CHART ON THE | | | LANDSCAPE PLAN TO REFLECT THE REQUIRED, APPROVED, AND | | | PROVIDED NUMBER OF TREES, FLOWERING TREES AND SHRUBS | | | BASED ON THE REQUIRED OPEN SPACE. | | | | | | 5. SATISFIED. PLEASE PROVIDE A CHART SHOWING PREVIOUSLY | | | APPROVED AND PROPOSED CALCULATIONS FOR THE BUFFER | | | INTERRUPTIONS THAT REQUIRED A WAIVER. | | | | | | 6. SATISFIED. PLEASE PROVIDE LOCATIONS OF LIGHTING ON | | | THE LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING. | | | | | | 7. NOT SATISFIED. PLEASE SHOW LOCATIONS OF WATER AND | | | SEWER LINES THAT SERVICE THE BUILDING, LOCATIONS OF | | | ABOVE GROUND VALVES, AND LOCATION OF DRAINAGE | | | STRUCTURES ON THE LANDSCAPE PLAN AND RESOLVE CONFLICTS | | | WITH LANDSCAPING. | | | THE LANDSCAPE PLANS CAN BE ENLARGED TO INCORPORATE THE | | | UTILITY LOCATIONS AND TREE LOCATIONS ADJUSTED TO AVOID | | | CONFLICTS. | | | | | | 8. SATISFIED. PLEASE INDICATE THE LOCATION OF THE 10 | | | FOOT LANDSCAPE BUFFER ALONG ARKONA COURT AND SOUTH | | | FLAGLER DRIVE REQUIRED PER SECTION 94-443(D). | | | | | | 9. SATISFIED. PLEASE PROVIDE THE DROUGHT TOLERANCE | | | LEVEL FOR EACH PLANT SPECIES ON THE PLANT LIST, TO SHOW | | | COMPLIANCE WITH SECTION 94-442(G) FLORIDA FRIENDLY | | | LANDSCAPING REQUIREMENTS. PLEASE LABEL THE SECTION IN | | | THE CHART AS SUCH. ADDING A COLUMN IDENTIFYING NATIVE | | | PLANTS IS ALSO SUGGESTED. | | | | | | 10. NOT SATISFIED. PLEASE PROVIDE SCREENING FOR ALL | | | GROUND MOUNTED EQUIPMENT AND UTILITIES. | | | PROVIDE A SCREENING HEDGE FOR WATER VALVES. | | | | | | 11. NOT SATISFIED. PLEASE PROVIDE A ROOT BARRIER DETAIL | | | AND SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT | | | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES | | | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY | | | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. | | | MORE DETAIL IS NEEDED ESPECIALLY FOR DRAINAGE LINES. | | | | | | 12. SATISFIED. PLEASE REVISE THE FLORIDA FRIENDLY | | | LANDSCAPE CHART PER SECTION 94-446 (G) AND PROVIDE | | | DOCUMENTATION FOR THE TYPE OF LANDSCAPE IRRIGATION | | | MOISTURE SENSOR OTHER THAN A RAIN SWITCH TO BE | | | PROVIDED, AND AN IRRIGATION PLAN INDICTING THE | | | LOCATIONS OF LOW, MODERATE AND HIGH WATER USE ZONES. | | | | | | 13. SATISFIED. PLEASE PROVIDE A NARRATIVE TO SHOW HOW | | | THE PLAN COMPLIES WITH THE REQUIREMENTS OF SECTION | | | 94-442 (E) SITE DESIGN FLEXIBILITY AS CLAIMED ON SHEET | | | L000.1. | | | ADDITIONAL COMMENTS 1/10/17: | | | 14. PLEASE PROVIDE TYPICAL CROSS SECTIONS OF THE | | | LANDSCAPE BUFFER AREAS FOR EACH OF THE FOUR SIDES OF | | | THE BUILDING TO DEMONSTRATE HOW THE LANDSCAPING AND | | | TREES WILL BE PLACED WITHIN THE ENGINEERING OF SLOPES | | | AND ELEVATIONS. | | | | | | 15. PLEASE REMOVE REFERENCE TO STONE MULCH OVER WEED | | | FABRIC FOR THE WATER VALVE AREA AT THE SOUTHEAST CORNER | | | OF THE SITE. ALL AREAS MUST BE LANDSCAPED WITH GRASS OR | | | GROUNDCOVER AND HAVE A SCREENING HEDGE. | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
09-09-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
09-09-2016 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
09-09-2016 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2016-09-09 10:50:14 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: THE MODERN Z16080012 | | | SEPTEMBER 9, 2016 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PLEASE PROVIDE A SITE DATA CHART ON THE LANDSCAPE | | | PLAN TO REFLECT THE REQUIRED, APPROVED, AND PROVIDED | | | OPEN SPACE AND LANDSCAPE AREA. | | | | | | 2. PLEASE PROVIDE CALCULATIONS TO SHOW THE LANDSCAPING | | | AROUND THE STRUCTURE MEETS THE 40% REQUIREMENT FOR | | | TREES, SHRUBS OR HEDGES PER SECTION 94-443 (E)(1). | | | | | | 3. PLEASE PROVIDE THE REQUIRED TREES WITHIN THE WEST | | | BUFFER, SPACED AS REQUIRED MEETING THE INTENT OF THE | | | ORIGINAL APPROVAL, ALSO AT THE SOUTHEAST CORNER OF THE | | | PROPERTY. | | | | | | 4. PLEASE PROVIDE A SITE DATA CHART ON THE LANDSCAPE | | | PLAN TO REFLECT THE REQUIRED, APPROVED, AND PROVIDED | | | NUMBER OF TREES, FLOWERING TREES AND SHRUBS BASED ON | | | THE REQUIRED OPEN SPACE. | | | | | | 5. PLEASE PROVIDE A CHART SHOWING PREVIOUSLY APPROVED | | | AND PROPOSED CALCULATIONS FOR THE BUFFER INTERRUPTIONS | | | THAT REQUIRED A WAIVER. | | | | | | 6. PLEASE PROVIDE LOCATIONS OF LIGHTING ON THE | | | LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING. | | | | | | 7. PLEASE SHOW LOCATIONS OF WATER AND SEWER LINES THAT | | | SERVICE THE BUILDING, LOCATIONS OF ABOVE GROUND VALVES, | | | AND LOCATION OF DRAINAGE STRUCTURES ON THE LANDSCAPE | | | PLAN AND RESOLVE CONFLICTS WITH LANDSCAPING. | | | | | | 8. PLEASE INDICATE THE LOCATION OF THE 10 FOOT | | | LANDSCAPE BUFFER ALONG ARKONA COURT AND SOUTH FLAGLER | | | DRIVE REQUIRED PER SECTION 94-443(D). | | | | | | 9. PLEASE PROVIDE THE DROUGHT TOLERANCE LEVEL FOR EACH | | | PLANT SPECIES ON THE PLANT LIST, TO SHOW COMPLIANCE | | | WITH SECTION 94-442(G) FLORIDA FRIENDLY LANDSCAPING | | | REQUIREMENTS. PLEASE LABEL THE SECTION IN THE CHART AS | | | SUCH. ADDING A COLUMN IDENTIFYING NATIVE PLANTS IS ALSO | | | SUGGESTED. | | | | | | 10. PLEASE PROVIDE SCREENING FOR ALL GROUND MOUNTED | | | EQUIPMENT AND UTILITIES. | | | | | | 11. PLEASE PROVIDE A ROOT BARRIER DETAIL AND SHOW | | | LOCATIONS OF ROOT BARRIERS TO PROTECT INFRASTRUCTURE | | | AND TREES FROM CONFLICTS. THIS INCLUDES WATER, SEWER, | | | DRAINAGE, SIDEWALKS AND CURBS, AND ANY FIELD STRUCTURES | | | THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 12. PLEASE REVISE THE FLORIDA FRIENDLY LANDSCAPE CHART | | | PER SECTION 94-446 (G) AND PROVIDE DOCUMENTATION FOR | | | THE TYPE OF LANDSCAPE IRRIGATION MOISTURE SENSOR OTHER | | | THAN A RAIN SWITCH TO BE PROVIDED, AND AN IRRIGATION | | | PLAN INDICTING THE LOCATIONS OF LOW, MODERATE AND HIGH | | | WATER USE ZONES. | | | | | | 13. PLEASE PROVIDE A NARRATIVE TO SHOW HOW THE PLAN | | | COMPLIES WITH THE REQUIREMENTS OF SECTION 94-442 (E) | | | SITE DESIGN FLEXIBILITY AS CLAIMED ON SHEET L000.1. | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
1 |
Status |
F |
Date |
09-14-2016 |
|
|
Cont ID |
|
| Sent By |
lle |
Date |
09-14-2016 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
mkhan |
Date |
09-14-2016 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2016-09-14 12:12:35 | 1515 S. FLAGLER DRIVE - THE MODERN | | | | | | PUBLIC UTILITIES - LAURA LE 561-494-1093 | | | | | | BELOW ARE THE WATER AND SEWER COMMENTS FROM A CURSORY | | | REVIEW OF CONCEPTUAL ENGINEERING PLAN SHEET C1.00: | | | | | | 1. THE CITY IS EVALUATING IMPACTS TO THE WATER AND | | | SEWER SYSTEMS DUE TO INCREASED DEMAND; | | | 2. INCLUDE APPLICABLE CITY OF WEST PALM BEACH STANDARD | | | WATER AND SEWER DETAILS UPDATED VERSION 2016; | | | 3. REFER TO THE CITY'S STANDARD DETAILS FOR ACCEPTABLE | | | PLACEMENT OF PROPOSED BACKFLOW PREVENTER ASSEMBLY, | | | METER BOX/VAULT, AND DOUBLE DETECTOR ASSEMBLY; | | | 4. SHOW ALL EXISTING UTILITIES ON OLIVE AVENUE, ARKONA | | | COURT, AND FLAGLER DRIVE. PROVIDE UTILITY CROSSING INFO | | | @ PROPOSED UTILITY CROSSINGS. | | | 5. EXISTING UTILITY SERVICE LINES, IF NOT USED BY THE | | | SITE REDEVELOPMENT, ARE TO BE CUT AND CAPPED AT THE | | | MAIN AND REMOVED IF LARGER THAN 2 INCHES IN DIAMETER; | | | 6. SUBMIT SIGNED & SEALED ENGINEER/MEP WATER AND SEWER | | | DEMAND CALCULATIONS (AVERAGE AND PEAK) FOR METER SIZING | | | SELECTION AND SERVICE SIZING. ALSO PROVIDE CALCULATIONS | | | FOR FIRE FLOW DEMAND; | | | 7. PROVIDE THE FIRE HYDRANT FLOW TEST DATA FROM | | | EXISTING FIRE HYDRANT USED FOR DESIGN; | | | 8. CALL OUT POINT OF SERVICE FOR WATER AND SEWER; | | | 9. CITY'S RECORD INFORMATION INDICATES THAT THE | | | EXISTING WM ON OLIVE AVENUE IS 8-INCH DIP WM. PLEASE | | | REVISE THE PLAN ACCORDINGLY; | | | 10. CITY'S RECORD INFORMATION SHOWS THAT FROM AN | | | EXISTING SAN MH AT THE OLIVE AVENUE AND CRANENEST WAY | | | INTERSECTION, THERE IS AN 8-INCH SAN SEWER THAT RUNS | | | EAST FOR APPROXIMATELY 320 LF AND TERMINATE ON THE | | | SUBJECT PROPERTY. THERE IS NEED TO TELEVISE THIS MAIN | | | AND CALL OUT THE PIPE SECTION WITHIN THE R/W TO BE | | | REMOVED IF NOT IN USE; | | | 11. THE PROPOSED 10-INCH SAN SEWER SERVICE CONNECTION | | | ON FLAGLER DRIVE NEEDS TO BE PERPENDICULAR TO THE | | | EXISTING SAN SEWER MAIN. ADD A SAN MH AT THE JUNCTION. |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
3 |
Status |
P |
Date |
04-17-2017 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
04-17-2017 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
04-17-2017 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2017-04-17 09:05:42 | THE FOLLOWING TWO STORMWATER COMMENTS HAVE NOT BEEN | | | FULLY ANSWERED. THESE SHOULD BE A CONDITION OF SITE | | | PLAN APPROVAL. | | | | | | 4. THE METHOD FOR CONTROLLING GROUNDWATER FROM ENTERING | | | THE SUBTERRANEAN PARKING GARAGE AND HOW GROUNDWATER | | | WILL BE DISCHARGED FROM THE SITE ARE TO BE APPROVED BY | | | THE CITY'S ENGINEERING SERVICES DEPARTMENT. | | | | | | 5. DRAINAGE CALCULATIONS THAT ACCOUNT FOR SEA LEVEL | | | RISE IMPACTS ON THE ONSITE STORMWATER SYSTEM SHALL BE | | | SUBMITTED WITH THE ENGINEERING PERMIT APPLICATION. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
01-11-2017 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
01-11-2017 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2017-01-11 11:05:40 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP:// | | | WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER | | | MITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE | | | AVAILABLE AT | | | HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX?. | | | PLEASE REVIEW THE MAPS AND VERIFY THAT THE NEW MAPS | | | WILL NOT IMPACT THE PROPOSED PROJECT. | | | | | | 2. THE CITY COMMISSION RECENTLY PASSED A RESOLUTION | | | INCREASING THE FREEBOARD REQUIREMENT TO ONE FOOT ABOVE | | | BASE FLOOD ELEVATION FOR STRUCTURES IN A SPECIAL FLOOD | | | HAZARD AREA. | | | | | | 3. INDICATE ON THE PAVING, GRADING AND DRAINAGE PLANS | | | THAT THE PIPE CONNECTIONS FOR BUILDING PLUMBING ARE FOR | | | RAIN WATER LEADERS ONLY. INDICATE IF THESE BUILDING | | | PLUMBING PIPES WILL BE USED FOR FLOW OTHER THAN STORM | | | WATER RUNOFF. | | | | | | 4. THE BUILDING INCLUDES A BASEMENT WITH A FINISHED | | | FLOOR ELEVATION AT (-)1.0 FT NGVD. INDICATE HOW | | | GROUNDWATER WILL BE CONTROLLED AND WHERE THE | | | GROUNDWATER WILL BE DISCHARGED TO. | | | | | | 5. THE ONSITE DRAINAGE SYSTEM SHOULD TAKE INTO ACCOUNT | | | SEA LEVEL RISE. | | | | | | 6. INCLUDE THE STORMWATER MANAGEMENT SYSTEM WITH THE | | | OTHER UTILITIES ON THE LANDSCAPE PLANS. | | | | | | 7. TRY TO AVOID PLACING MANHOLES WITHIN THE SIDEWALK. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. PROVIDE ENGINEERING CALCULATIONS SIGNED AND SEALED | | | BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER FOR THE | | | MINIMUM REQUIRED STORM RUNOFF WATER QUALITY TREATMENT | | | AND PEAK FLOOD STAGES FOR 5-YEAR 1-DAY, 25-YEAR 3-DAY | | | AND 100-YEAR 3-DAY DESIGN STORMS PER SFWMD CRITERIA. | | | | | | 3. PROVIDE A COPY OF THE SFWMD ERP FOR THIS PROJECT. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
09-14-2016 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
09-14-2016 |
Time |
08:19 |
Rev Time |
|
| Received By |
tward |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2016-09-14 08:22:33 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP:// | | | WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER | | | MITS-APPLICATIONS | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE | | | AVAILABLE AT | | | HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX?. | | | PLEASE REVIEW THE MAPS AND VERIFY THAT THE NEW MAPS | | | WILL NOT IMPACT THE PROPOSED PROJECT. | | | | | | 2. THE CITY COMMISSION RECENTLY PASSED A RESOLUTION | | | INCREASING THE FREEBOARD REQUIREMENT TO ONE FOOT ABOVE | | | BASE FLOOD ELEVATION FOR STRUCTURES IN A SPECIAL FLOOD | | | HAZARD AREA. | | | | | | 3. SHOW ALL UTILITIES WITHIN ARKONA COURT RIGHT-OF-WAY | | | BETWEEN OLIVE AVE AND FLAGLER DRIVE. | | | | | | 4. INDICATE IF THE MID-BLOCK STORM CONNECTION ON ARKONA | | | COURT IS AT AN EXISTING OR A PROPOSED MANHOLE. IF AT AN | | | EXISTING MANHOLE, VERIFY THERE IS SUFFICIENT WALL AREA | | | TO MAKE THE CONNECTION. | | | | | | 5. VERIFY THERE IS SUFFICIENT WALL AREA FOR THE STORM | | | CONNECTION TO THE EXISTING MANHOLE AT FLAGLER DRIVE. | | | | | | 6. STORM PIPE SIZES ARE NOT SHOWN. MINIMUM PIPE SIZE | | | WITHIN THE RIGHT-OF-WAY IS 15? RCP. | | | | | | 7. VALLEY GUTTER (DROP CURB) MAY BE REQUIRED ACROSS THE | | | ONSTREET PARKING SPACES. | | | | | | 8. SHOW UTILITIES, SWALES AND STORMWATER DETENTION | | | AREAS ON THE LANDSCAPE PLANS. | | | | | | 9. CONTACT THE PUBLIC UTILITIES DEPARTMENT ABOUT THE | | | NEED FOR AN EASEMENT FOR THE EXISTING FIRE HYDRANT AT | | | SOUTHEAST CORNER OF SITE. | | | | | | 10. ENGINEERING PLANS WERE NOT SIGNED AND SEALED. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE | | | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | | | 2. PROVIDE ENGINEERING CALCULATIONS SIGNED AND SEALED | | | BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER | | | INDICATING THE CHANGES TO THE ONSITE PEAK FLOOD STAGES | | | WILL NOT EXCEED THE SFWMD PERMITTED FLOOD STAGES. | | | | | | 3. DETAILS SHEETS WILL NEED TO UTILIZE STANDARD CITY OF | | | WEST PALM BEACH DETAILS, WHICH MAY BE DOWNLOADED AT HTT | | | P://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS, | | | -PERMITS-APPLICATIONS | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
P |
Date |
01-10-2017 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
01-10-2017 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2017-01-10 10:29:25 | PASSED WITH CONDITIONS: | | | 1. PREVIOUS COMMENTS OF EASEMENTS AND AGREEMENTS BEING | | | PROVIDED. | | | 2. UTILITY DEPT. APPROVAL OF CONNECTIONS AND ANY | | | REQUIRED IMPROVEMENTS. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
09-09-2016 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
09-09-2016 |
Time |
13:07 |
Rev Time |
|
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2016-09-09 13:19:17 | 1. MAINTENANCE AGREEMENT WILL BE REQUIRED FOR ANY | | | IMPROVEMENTS AND/OR LANDSCAPING WITHIN THE | | | RIGHT-OF-WAY. | | | 2. NEED TO SEE LOCATIONS AND ELEVATIONS ALONG NORTH R/W | | | OF ARKONA. ADD ELEVATIONS ALONG WEST EDGE OF PAVEMENT | | | OF FLAGLER DRIVE. | | | 3. SIDEWALK/ACCESS EASEMENT WILL BE REQUIRED ALONG WITH | | | ANY UTILITY EASEMENTS. | | | 4. SITE/CIVIL PERMIT WILL BE REQUIRED THROUGH | | | ENGINEERING SERVICES. | | | 5. GARBAGE CONTAINERS WILL NEED TO BE PULLED OUT FOR | | | PICK-UP. | | | 6. SURVEY INCLUDES PARCEL B WHICH IS NOT PART OF SITE | | | PLAN. | | | 7. UTILITY CONNECTIONS WILL NEED TO BE APPROVED BY THE | | | UTILITIES DEPT. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
F |
Date |
01-17-2017 |
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
1.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2017-01-17 11:34:30 | RESUBMITTAL 1/6/17 | | | PLANNING BOARD CASE NO. 1559J | | | 1515 SOUTH FLAGLER DRIVE | | | | | | - CONTACT UYEN DANG @ (561) 494-1087 | | | | | | 1. IF PARKING ON ARKONA CT. IS PUBLIC PARKING, REQUEST | | | TO HAVE A 2 HOUR PARKING LIMIT AT THESE LOCATIONS. | | | 2. PROVIDE PHOTOMETRICS. | | | 3. PROVIDE SIDEWALK ACCESS EAST AT THE WALKWAY OF | | | SERVICE ENTRANCE. CONSIDER HATCHING OR PROVIDE A | | | DECORATIVE TREATMENT TO DISCOURAGE CARS QUEUING OR | | | PARKED IN THIS PEDESTRIAN CONFLICT ZONE. PEDESTRIAN | | | ACCESS TO BE KEPT CLEAR OF VEHICLES AT THIS TRIANGULAR | | | AREA. | | | 4. THE ENTIRE WIDTH AND LENGTH OF ARKONA CT ARE TO BE | | | MILL AND PAVED 1? OF SP 9.5 | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
09-12-2016 |
|
|
Cont ID |
|
| Sent By |
KUDANG |
Date |
09-12-2016 |
Time |
|
Rev Time |
2.00 |
| Received By |
|
Date |
09-12-2016 |
Time |
|
Sent To |
Z |
|
| Notes |
| 2016-09-12 12:31:37 | PLANNING BOARD CASE NO. 1559J | | | 1515 SOUTH FLAGLER DRIVE | | | | | | - CONTACT UYEN DANG @ (561) 494-1087 | | | | | | 1. EXISTING WIDTH OF ARKONA COURT IS NOT WIDE ENOUGH | | | FOR ANGLED PARKING. REVISE DESIGN FOR PARALLEL PARKING. | | | DEPTH OF STALL SHALL BE LIMITED TO 8?. | | | 2. ARE THE WEST PARKING SPACES ON ARKONA COURT PUBLIC | | | PARKING SPACES? IF SO, IT SHOULD BE CONTAINED WITHIN | | | THE RIGHTS OF WAY. | | | 3. WHAT TYPE OF APPROACH CONTROL (STOP OR YIELD) IS | | | PROPOSED FOR THE CROSSWALK EAST WEST ON FLAGLER DRIVE? | | | THIS CROSSWALK SHOULD BE UNMARKED. CONSIDER | | | GUIDANCE FROM A STUDY PERFORMED FOR FHWA IN 2002 BY | | | ZEGEER, STEWART, AND HUANG ENTITLED "SAFETY EFFECTS OF | | | MARKED VS UNMARKED CROSSWALKS AT UNCONTROLLED | | | LOCATIONS". | | | 4. CROSSWALK SHALL BE STAMPED ASPHALT AND NOT PAVERS. A | | | MAINTENANCE AGREEMENT IS NEEDED AND SKID TESTS SHALL BE | | | PERFORMED EVERY 3 YEARS BASED ON THE PERFORMANCE | | | SPECIFICATIONS. | | | 5. AUTOTURN DRAWINGS SHOW THAT THE DRIVE AISLE NEEDED | | | TO BE TWO-WAY INSTEAD OF ONE-WAY. | | | 6. PROVIDE RESTORATION LIMITS FOR THE WATER AND SEWER | | | TAP. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
04-27-2017 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
04-27-2017 |
Time |
15:46 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
04-27-2017 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
04-18-2017 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
04-18-2017 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
04-14-2017 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2017-04-18 13:28:47 | PB 1559J - 2ND PPRC RESUBMITTAL 1 | | | 1515 SOUTH FLAGLER CONDO (A.K.A. THE MODERN PD) | | | 1515 SOUTH FLAGLER | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN | | | (11) [IF MAJOR AMENDMENT] OR FIVE (5) [IF REMAINS MINOR | | | AMENDMENT] PAPER COPIES AND AN ELECTRONIC COPY IN .PDF | | | FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE COMMENTS WITHIN 60 DAYS FROM | | | THE DATE OF THESE COMMENTS (BY JUNE 18, 2017), THE CASE | | | SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL | | | REQUIRE A NEW DEVELOPMENT APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($60 FOR | | | MINOR AMENDMENT). | | | | | | 1) PLEASE PROVIDE AN UPDATE ON CONDITION 2.M. OF | | | SECTION 4 OF ORDINANCE NO. 4245-09, WHICH REQUIRES | | | MEETING WITH THE ADJACENT NEIGHBORS ON THE DESIGN OF | | | THE PASSIVE PARK. PLEASE NOTE THAT FINAL PARK LAYOUT, | | | IF IT DIFFERS THAN WHAT HAS BEEN SUBMITTED, WILL | | | REQUIRE A MINOR SITE PLAN AMENDMENT. THE SPECIFIC TYPES | | | OF BENCHES, LIGHTS, ETC. WILL BE REVIEWED AT THE TIME | | | OF BUILDING PERMIT SO LONG AS THE LOCATIONS ARE | | | CONSISTENT WITH THE SITE PLAN. | | | | | | 2) THE NEWLY SHOWN THREE PARALLEL COMPACT SPACES ON | | | SHEET A115 DO NOT APPEAR TO MEET THE MINIMUM | | | REQUIREMENT OF 8 FEET BY 20 FEET PER SPACE. PLEASE | | | INCLUDE THE DIMENSIONS ON THE PLAN. | | | | | | 3) PLEASE PROVIDE THE BICYCLE PAD DIMENSIONS ON SHEET | | | A115. THE PAD FOR THREE RACKS SHALL BE A MINIMUM OF SIX | | | FEET (DEPTH) BY NINE FEET (WIDTH). | | | | | | 4) PLEASE PROVIDE A CUT SHEET FOR THE BICYCLE STORAGE | | | ROOM THAT SHOWS THE SIDE WITH THE THREE RACKS HAVING A | | | MINIMUM OF SIX FEET BY NINE FEET (PLEASE BE AWARE OF | | | THE DOOR SWING) AND THE TWO RACK SIDE HAVING A MINIMUM | | | OF SIX FEET BY 6.5 FEET. | | | | | | 5) CONDITION: AT TIME OF BUILDING PERMIT, PHOTOMETRIC | | | PLANS SHALL BE PROVIDED THAT VERIFY THAT THERE WILL BE | | | NO OFF-SITE GLARE AND THAT PROVIDES THE FOOT CANDLE | | | LEVELS AT THE RESIDENTIAL PROPERTY LINE ON THE SOUTH | | | SIDE OF THE SITE. | | | | | | 6) CONDITION: THE INSTALLATION OF A FREESTANDING SIGN | | | WILL REQUIRE THE APPROVAL OF A MINOR SITE PLAN | | | AMENDMENT. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
01-10-2017 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
01-10-2017 |
Time |
09:59 |
Rev Time |
8.00 |
| Received By |
eschneid |
Date |
01-10-2017 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2017-01-10 09:59:37 | PB 1559J ? 2ND PPRC REVIEW | | | 1515 SOUTH FLAGLER CONDO (A.K.A. THE MODERN PD) | | | 1515 SOUTH FLAGLER | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN | | | (11) [IF MAJOR AMENDMENT] OR FIVE (5) [IF REMAINS MINOR | | | AMENDMENT] PAPER COPIES AND AN ELECTRONIC COPY IN .PDF | | | FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - IF THE PLAN ELEMENTS REQUIRING A MAJOR AMENDMENT | | | REMAIN THEN THE PPRC COMMENTS SHALL BE SUFFICIENTLY | | | ADDRESSED AND SUBMITTED TO THE PLANNING DIVISION BY 5 | | | PM ON FRIDAY, JANUARY 27, 2017, TO BE ELIGIBLE TO BE | | | SCHEDULED FOR THE MARCH 21, 2017 PLANNING BOARD | | | MEETING. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS | | | FROM THE DATE OF THE PPRC MEETING (BY MARCH 11, 2017), | | | THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER | | | ACTION SHALL REQUIRE A NEW DEVELOPMENT APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($60 FOR | | | MINOR AMENDMENT). | | | | | | - IF THE CASE IS A MAJOR AMENDMENT THEN PUBLIC HEARING | | | NOTIFICATION SIGNAGE SHALL BE POSTED IN ACCORDANCE WITH | | | THE REQUIREMENTS OF SECTION 94-39(I)(5) OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS AND AN ADDITIONAL | | | $2,916 IN APPLICATION AND ADVERTISING FEES ARE | | | REQUIRED. YOU WILL ALSO BE RESPONSIBLE FOR MAILERS. | | | | | | - IF THIS CONTINUES AS A MINOR AMENDMENT, IN ACCORDANCE | | | WITH SECTION 94-35(D)(6)A, SINCE THIS IS A NEW SITE | | | PLAN WITHIN A PLANNED DEVELOPMENT, YOU NEED TO GET | | | APPROVAL OF A LEVEL II SITE PLAN CONCURRENT WITH THE | | | MINOR AMENDMENT. WHILE NO ADDITIONAL APPLICATION | | | DOCUMENTS OR PLANS ARE REQUIRED AS THEY WOULD BE A | | | DUPLICATION OF THE MATERIAL SUBMITTED WITH THE MINOR | | | AMENDMENT APPLICATION, YOU ARE REQUIRED TO PAY THE | | | APPLICATION FEE OF $1,500. | | | | | | 1) SHEET A125 SHOWS THE NORTH DIMENSION TO THE FACE OF | | | THE BALCONIES AT 30 FEET 10 INCHES, WHILE SHEET A127 | | | SHOWS THIS DIMENSION AS 30 FEET 9 3/4 INCHES. WHILE | | | BOTH MEET THE BALCONY INTRUSION WAIVER, PLEASE ENSURE | | | THAT ALL DRAWINGS SHOW THE SAME DIMENTIONS. | | | | | | 2) THE REAR PEDESTAL SETBACK FOR THE APPROVED MODERN | | | RPD IS 24 FEET 4 INCHES. WHILE THE ELEVATION DRAWINGS | | | AND THE SITE PLAN SHOW THIS DIMENSION LINE, IT APPEARS | | | THAT IT IS MARKING THE INSIDE FACE OF THE WALL NOT THE | | | EXTERIOR FACE OF THE WALL. PLEASE REVIEW AND CORRECT | | | THE DRAWINGS TO SHOW COMPLIANCE WITH THE APPROVED | | | PEDESTAL SETBACK. ADDITIONALLY, PLEASE PROVIDE THE REAR | | | SETBACK DIMENSION FOR THE PORTION OF THE PEDESTAL NORTH | | | OF THE PORTION OF THE LOT WHICH EXTENDS TO SOUTH OLIVE | | | AVENUE (ADJACENT TO SMITH AND MOORE ARCHITECTS) SO THAT | | | STAFF CAN VERIFY COMPLIANCE WITH THE APPROVED SETBACK | | | WAIVER. | | | | | | 3) PROVIDE THE BUILDING SETBACKS FOR THE PEDESTAL ON AT | | | LEAST ONE OF THE CIVIL PLAN SHEETS. | | | | | | 4) PLEASE CLARIFY, THE FPL VAULT, THE MAIN ELECTRIC, | | | THE SWITCH GEAR AND EMERGENCY GENERATOR ROOMS HAVE THE | | | FLOOR A BIT BELOW GRADE WITH THE ROOF ELEVATION AT 24 | | | FEET 4 INCH NGVD? HOW WILL THIS ROOF BE TREATED? | | | | | | 5) THE APPROVED MODERN RPD INCLUDED A PUBLICLY | | | ACCESSIBLE PASSIVE PARK WITH AN AREA OF 11,455 ALONG | | | FLAGLER DRIVE. THE 12,442 SQUARE FOOT AREA SHOWN ON | | | SHEET L000.5 INCLUDES THE PUBLIC SIDEWALK, WHICH MAY | | | NOT BE INCLUDED IN THE PASSIVE PARK AREA. THIS DIAGRAM | | | NEEDS TO BE REVISED TO CORRECTLY SHOW THE REQUIRED | | | AMOUNT OF PASSIVE PARK WHOLLY ON-SITE. THE PROVIDED | | | PLANS SHOW A LESSER AREA GIVEN UP AS THE PASSIVE PARK. | | | | | | 6) PLEASE PROVIDE AN UPDATE ON CONDITION 2.M. OF | | | SECTION 4 OF ORDINANCE NO. 4245-09, WHICH REQUIRES | | | MEETING WITH THE ADJACENT NEIGHBORS ON THE DESIGN OF | | | THE PASSIVE PARK. ZONING STAFF DOES NOT HAVE ANY ISSUES | | | WITH THE CONCEPTUAL DESIGN OF THE PLAZA. DETAILS, SUCH | | | AS THE HEIGHT OF THE WALL, SEAT WALL AND BENCHES WAS | | | NOT BEEN PROVIDED. ENSURE THERE IS ADEQUATE LIGHTING | | | FOR THE EVENING HOURS WHEN THE PARK MAY BE IN USE AND | | | TO DISCOURAGE USE OF THE PARK FOR OVERNIGHT | | | ACCOMMODATIONS. THE WALLS AND THE BENCH WALLS SHOULD BE | | | DESIGNED WITH ANTI-SKATE BOARD GRINDING FEATURES ? | | | AFTERMARKET ADD-ONS RARELY LOOK AS GOOD AS IF THE | | | FEATURES WERE DESIGNED IN THE ORIGINAL PLAN. THE | | | BENCHES ARE ALL UNIQUE SHAPES WHICH WOULD REQUIRE | | | CUSTOM WORK. IT MAY BE MORE PRACTICAL HAVE A UNIFORM | | | DESIGN SHOWN ON THE PLANS AT THIS STAGE, RATHER THAN AT | | | THE PERMITTING PHASE, THOUGH THIS IS UP TO YOU. | | | WHICHEVER BENCH ROUTE IS CHOSEN, PLEASE ENSURE THAT THE | | | BENCHES ARE DESIGNED IN SUCH A WAY TO MAKE SLEEPING ON | | | THEM UNCOMFORTABLE. | | | | | | 7) THE PARKING TABLE PROVIDED WITH THE PLAN DOES NOT | | | INCLUDE THE PARKING TABLE SHALL INCLUDE THE NUMBER OF | | | REQUIRED AND PROVIDED PARKING SPACES, ADA PARKING | | | SPACES, GUEST SPACES AND BICYCLE SPACES. EXAMPLE: | | | | | | 84 UNITS WITH 2+ BEDROOMS X 2 SPACES PER UNIT = 168 | | | PARKING SPACES | | | GUEST PARKING IS 1 SPACE PER 10 UNITS = 9 PARKING | | | SPACES | | | STAFF PARKING PER THE APPROVED MODERN = 6 SPACES | | | TOTAL REQUIRED PARKING REQUIRED = 183 SPACES | | | TOTAL PARKING PROVIDED = *** SPACES | | | | | | THE PROVIDED SPACES ON THE TABLE SHALL BE BROKEN DOWN | | | BY NUMBER OF EACH TYPE OF SPACE (REGULAR, ADA, | | | COMPACT). PLEASE SEE THE MODERN APPROVAL FOR AN | | | EXAMPLE. | | | | | | 8) PLEASE NOTE THAT THE 11 ON-STREET PARKING SPACES | | | WERE APPROVED BY THE MODERN ORDINANCE AS PUBLIC PARKING | | | SPACES (CONDITION 2.D. OF THE ORDINANCE) SEPARATE FROM | | | THE PARKING SPACES THAT WERE PROVIDED TO MEET THE | | | REQUIRED PARKING. AS SUCH, THE 11 ON-STREET PARKING | | | SPACES MAY NOT BE COUNTED TOWARD MEETING THE REQUIRED | | | 183 PARKING SPACES. STAFF COUNTS ONLY 173 PARKING | | | SPACES ON-SITE, WHICH DOES NOT MATCH THE MINIMUM | | | REQUIRED BY THE MODERN ORDINANCE. | | | 9) THE PARKING DETAILS PROVIDED ON SHEET A114.1 DO NOT | | | MEET CITY STANDARDS AND MUST BE REPLACED WITH THE | | | STANDARD CITY DETAIL. ADDITIONALLY, THEY MUST INCLUDE A | | | COMPACT SPACE DETAIL. PLEASE NOTE THAT THE CORRECT CITY | | | DETAIL WAS PROVIDED ON SHEET C-1 AS PART OF THE | | | ORIGINAL SUBMITTAL. | | | | | | 10) PLEASE PROVIDE DIMENSIONS FOR THE BICYCLE STORAGE | | | ROOM AND DETAILS, MEETING CITY STANDARDS, FOR THE | | | BICYCLE RACKS AND PARKING PAD. PLEASE NOTE THAT THE | | | RACKS SHOWN ON THE PLANS DO NOT MEET CITY STANDARDS. | | | THE PARKING TABLE SHALL INCLUDE THE NUMBER OF REQUIRED | | | AND PROVIDED SPACES. | | | | | | 11) HOW WILL RESIDENTS BRING THEIR BICYCLES TO THE | | | STORAGE ROOM? RIDING THE BICYCLES THROUGH THE PARKING | | | GARAGE IS NOT A SAFE ROUTE. IS THE INTENTION FOR ACCESS | | | TO BE THROUGH THE HALLWAY WHICH LEADS OUT TO ARKONA | | | COURT? HOW WILL ACCESS CONTROL BE PROVIDED? | | | | | | 12) IT IS ANTICIPATED THAT THE RESIDENTS OF THE | | | BUILDING MAY HAVE GUESTS ARRIVE VIA BICYCLE, THERE | | | SHALL BE AT LEAST ONE, PREFERABLY TWO BICYCLE RACKS | | | (TWO OR FOUR BICYCLE PARKING SPACES) PROVIDED NEAR THE | | | ENTRANCE TO THE BUILDING IN THE ARRIVAL COURT IN | | | ACCORDANCE WITH SECTION 94-485(Q). THIS BICYCLE PARKING | | | MAY BE COUNTED TOWARD MEETING THE REQUIRED 10 SPACES, | | | WITH THE BICYCLE STORAGE ROOM NUMBER REDUCED | | | ACCORDINGLY (ALTHOUGH STAFF RECOMMENDS PROVIDING MORE | | | THAN 10 TOTAL SPACES). | | | | | | 13) PROVIDE THE DIMENSIONS OF THE NEW 22 FOOT ARKONA | | | COURT RIGHT-OF-WAY ON THE CIVIL PLANS. | | | | | | 14) NO PHOTOMETRIC PLANS WERE PROVIDED. PLEASE PROVIDE | | | SO THAT STAFF CAN VERIFY NOW THAT THERE WILL BE NO | | | ISSUES AT TIME OF PERMITTING. | | | | | | 15) PROVIDE BETTER DETAILS ON WHAT THE EXTERIOR FACADE | | | OF THE PEDESTAL WILL LOOK LIKE FROM THE EXTERIOR | | | PROPERTIES AND RIGHTS-OF-WAY. THE ELEVATIONS ARE NOT | | | CLEAR WHERE IT WILL BE A WALL WITH LANDSCAPE IN FRONT | | | OR A SLOPE OF DIRT WITH SOD/LANDSCAPE COVERING THE | | | WALL. STAFF EXPECTED MORE OF WHAT MATERIALS WOULD BE | | | EXPOSED IF THERE WAS NO SLOPE. THE TOWER DOES LABEL | | | MATERIALS. | | | | | | 14) THERE NEEDS TO BE A DATA TABLE WHICH STATES THE | | | TOTAL NUMBER OF UNITS IN THE BUILDING. THE TABLE NEEDS | | | TO INCLUDE THAT THERE ARE THREE GUEST SUITES WITH A | | | NOTE REPLICATING THE ORDINANCE PROHIBITION ON THEM | | | CONTAINING KITCHEN FACILITIES (CONDITION 10 OF THE | | | ORDINANCE). | | | | | | 15) IS A MONUMENT SIGN PROPOSED FOR THE BUILDING? IF | | | SO, PLEASE SHOW ITS LOCATION ON THE PLANS SO STAFF CAN | | | VERIFY THAT IT IS NOT IN CONFLICT WITH SITE LINES OR | | | LANDSCAPE. | | | | | | 16) THE ZONING STAFF IDENTIFIES ITEMS 2 AND 6 AS ITEMS | | | THAT FAIL TO CONFORM TO THE PROVISIONS OF THE MODERN | | | APPROVAL, ORDINANCE NO. 4195-09, AND WOULD NEED | | | APPROVAL BY THE CITY COMMISSION AS REVISED WAIVERS AS | | | PART OF A MAJOR PLANNED DEVELOPMENT AMENDMENT. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
09-13-2016 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
09-13-2016 |
Time |
10:26 |
Rev Time |
8.00 |
| Received By |
eschneid |
Date |
09-13-2016 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2016-09-13 10:26:58 | PB 1559J | | | 1515 SOUTH FLAGLER CONDO (A.K.A. THE MODERN PD) | | | 1515 SOUTH FLAGLER | | | | | | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | | | | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN | | | WRITTEN FORMAT. | | | | | | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN | | | (11) [IF MAJOR AMENDMENT] OR FIVE (5) [IF REMAINS MINOR | | | AMENDMENT] PAPER COPIES AND AN ELECTRONIC COPY IN .PDF | | | FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE | | | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS | | | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL | | | COMMENTS. | | | | | | - IF THE PLAN ELEMENTS REQUIRING A MAJOR AMENDMENT | | | REMAIN THEN THE PPRC COMMENTS SHALL BE SUFFICIENTLY | | | ADDRESSED AND SUBMITTED TO THE PLANNING DIVISION BY 5 | | | PM ON FRIDAY, SEPTEMBER 30, 2016, TO BE ELIGIBLE TO BE | | | SCHEDULED FOR THE NOVEMBER 15, 2016 PLANNING BOARD | | | MEETING. | | | | | | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT | | | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS | | | FROM THE DATE OF THE PPRC MEETING (BY NOVEMBER 14, | | | 2016), THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY | | | FURTHER ACTION SHALL REQUIRE A NEW DEVELOPMENT | | | APPLICATION. | | | | | | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($60). | | | | | | - IF THE CASE IS A MAJOR AMENDMENT THEN PUBLIC HEARING | | | NOTIFICATION SIGNAGE SHALL BE POSTED IN ACCORDANCE WITH | | | THE REQUIREMENTS OF SECTION 94-39(I)(5) OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS AND AN ADDITIONAL | | | $2,916 IN APPLICATION AND ADVERTISING FEES ARE | | | REQUIRED. YOU WILL ALSO BE RESPONSIBLE FOR MAILERS. | | | | | | - IF THIS CONTINUES AS A MINOR AMENDMENT, IN ACCORDANCE | | | WITH SECTION 94-35(D)(6)A, SINCE THIS IS A NEW SITE | | | PLAN WITHIN A PLANNED DEVELOPMENT, YOU NEED TO GET | | | APPROVAL OF A LEVEL II SITE PLAN CONCURRENT WITH THE | | | MINOR AMENDMENT. WHILE NO ADDITIONAL APPLICATION | | | DOCUMENTS OR PLANS ARE REQUIRED AS THEY WOULD BE A | | | DUPLICATION OF THE MATERIAL SUBMITTED WITH THE MINOR | | | AMENDMENT APPLICATION, YOU ARE REQUIRED TO PAY THE | | | APPLICATION FEE OF $1,500. | | | | | | 1) THE SOUTH SIDE PEDESTAL SETBACK FOR THE APPROVED | | | MODERN RPD IS 24 FEET. THE SOUTHERN SETBACK SHOWN ON | | | SHEET A111 IS ONLY 23 FEET 10 INCHES AND SHEET A125 IS | | | ONLY 23 FEET. THIS NEW REDUCED SETBACK REQUIRES A MAJOR | | | AMENDMENT APPROVAL BY THE CITY COMMISSION. | | | | | | 2) THE ENTRY CANOPY ON THE NORTH SIDE OF THE BUILDING | | | IS SHOWN AT FIVE (5) FEET FROM THE NORTH PROPERTY LINE. | | | THE NORTH SIDE SETBACK FOR THE MODERN RPD IS | | | ESTABLISHED AT 34 FEET 10 INCHES, WITH A STRUCTURAL | | | INTRUSION INTO THE SETBACK FOR THE NORTH SIDE TO BE A | | | MAXIMUM OF SIX (6) FEET, WHICH REQUIRES ALL ELEMENTS ON | | | THE NORTH SIDE OF THE BUILDING TO BE A MINIMUM OF 28 | | | FEET 10 INCHES FROM THE NORTH PROPERTY LINE. THE | | | CANOPY, AS SHOWN, DOES NOT CONFORM TO THE REQUIRED | | | SETBACK AND THUS REQUIRES A NEW WAIVER APPROVAL BY THE | | | CITY COMMISSION AS PART OF A MAJOR AMENDMENT. | | | | | | 3) THE BUILDING COMPARISON DRAWINGS ON SHEET A125 AND | | | A127 SHOW DIFFERING LOCATIONS FOR THE OUTLINE OF THE | | | EXISTING MODERN. THE A127 ELEVATION SHOWS THE TOWER | | | BALCONIES ENCROACHING INTO THE PERMITTED SETBACKS, | | | WHICH REQUIRES A NEW WAIVER APPROVAL BY THE CITY | | | COMMISSION AS PART OF A MAJOR AMENDMENT. | | | | | | 4) THE REAR PEDESTAL SETBACK FOR THE APPROVED MODERN | | | RPD IS 24 FEET 4 INCHES. SHEET A129 SHOWS THE NORTHWEST | | | PORTION OF THE PEDESTAL WITH A SETBACK OF ONLY 13 FEET | | | 6 5/8 INCHES. PLEASE NOTE THAT THE SETBACK IS MEASURED | | | FROM THE PROPERTY LINE AT THE POINT ADJACENT TO THE | | | SPECIFIC PORTION OF THE PEDESTAL. SINCE THE PROPERTY | | | LINE JOGS EASTWARD NORTH OF THE STRIP OF LAND LEADING | | | TO SOUTH OLIVE AVENUE, THE BUILDING PEDESTAL NEEDS TO | | | SHIFT ACCORDINGLY TO MAINTAIN THE APPROVED SETBACK. THE | | | BUILDING AS SHOWN REQUIRES A NEW WAIVER APPROVAL BY THE | | | CITY COMMISSION AS PART OF A MAJOR AMENDMENT. | | | | | | 5) THE HEIGHT OF THE PEDESTAL, INCLUDING THE PARKING | | | LIFT AND THE RAISED PLANTER (SHEET A129) IS THREE FEET | | | HIGHER THAN THE APPROVED MODERN RPD HEIGHT OF THE | | | PEDESTAL, WHICH IS AN INCREASE OF MORE THAN 5 PERCENT | | | OF THE PEDESTAL HEIGHT ALONG THE WESTERN SIDE OF THE | | | PROPERTY. THIS EXCEEDS WHAT STAFF CAN APPROVE AS PART | | | OF A MINOR AMENDMENT. | | | | | | 6) PROVIDE DETAILS, TO INCLUDE ELEVATIONS OF THE | | | PROPOSED COOLING TOWER AND ENCLOSURE AND THE | | | TRANSFORMERS. PLEASE NOTE THAT MECHANICAL EQUIPMENT MAY | | | ONLY ENCROACH FOUR (4) FEET INTO A REQUIRED SETBACK. | | | BOTH OF THESE ENCROACH MORE THAN THE PERMITTED FOUR (4) | | | FEET AND THUS, AS SHOWN, REQUIRE A NEW WAIVER APPROVAL | | | BY THE CITY COMMISSION AS PART OF A MAJOR AMENDMENT. | | | | | | 7) THE APPROVED MODERN RPD INCLUDED A PUBLICLY | | | ACCESSIBLE PASSIVE PARK WITH AN AREA OF 11,455 ALONG | | | FLAGLER DRIVE. PLEASE SHOW THIS AREA AND ITS CONCEPTUAL | | | DESIGN, WITH DETAILS, ON THE PROPOSED PLAN. THE | | | PROVIDED PLANS SHOW A LESSER AREA GIVEN UP AS THE | | | PASSIVE PARK. | | | | | | 8) THE SURVEY LISTS A PRIVATE ROAD EASEMENT OVER A | | | PORTION OF THE STRIP OF LAND THAT LEADS TO SOUTH OLIVE | | | AVENUE. PROVIDE A COPY OF THE EASEMENT SO THAT STAFF | | | CAN VERIFY HOW THE STRIP OF LAND IS ENCUMBERED AND IF | | | THE PROPOSED WATER METER AND BY-PASS PIPING IS | | | PERMITTED. | | | | | | 9) PLEASE PROVIDE DETAILS FOR THE PROPOSED WATER METER | | | AND BY-PASS PIPING, TO INCLUDE HOW IT LOOKS ABOVE | | | GROUND. THE CIVIL PLAN SHOWS AN ENCROACHMENT OF THE | | | PRIVATE ROAD EASEMENT. ADDITIONALLY, THE APPROVED | | | MODERN RPD REQUIRES THAT THE ENTIRE 12 FOOT WIDE STRIP | | | IS GRANTED AN ACCESS EASEMENT. | | | | | | 10) ARE RESIDENTS GOING TO HAVE ASSIGNED PARKING | | | SPACES? | | | | | | 11) THE PLANS DO NOT INCLUDE A PARKING TABLE. THE | | | PARKING TABLE SHALL INCLUDE THE NUMBER OF REQUIRED AND | | | PROPOSED PARKING SPACES, ADA PARKING SPACES, GUEST | | | SPACES AND BICYCLE SPACES. IT SHALL ALSO CLEARLY LIST | | | THE NUMBER OF TANDEM AND LIFT SPACES. | | | | | | 12) PLEASE NOTE THAT THE GENERAL CITY PARKING CODE DOES | | | NOT COUNT TANDEM (OR TRIDEM) OR LIFT PARKING SPACES AS | | | COUNTING TOWARD MEETING REQUIRED PARKING SPACES, BUT | | | THEY MAY BE PROVIDED AS EXTRA SPACES. THEREFORE 105 OF | | | THE PARKING SPACES SHOWN ON THE PLAN MAY NOT BE COUNTED | | | AS MEETING THE PARKING REQUIREMENTS WITHOUT THE CITY | | | COMMISSION SPECIFICALLY ADDING A CONDITION THAT THESE | | | SPACES COUNT TOWARD MEETING PARKING REQUIREMENTS | | | (ADOPTING THE DOWNTOWN PARKING ALLOWANCE) AS PART OF A | | | MAJOR AMENDMENT. THE EXISTING MODERN RPD APPROVAL | | | PROVIDED 196 PARKING SPACES THAT WERE NOT TANDEM SPACES | | | AND CLEARLY EXCLUDED THE TANDEM SPACES FROM MEETING THE | | | PARING REQUIREMENTS. THE TABLE SHALL CLEARLY STATE THAT | | | THE TANDEM (AND TRIDEM) AND LIFT PARKING WILL ONLY BE | | | UTILIZED BY VALET. | | | | | | 13) THE DIMENSIONS OF THE PARKING SPACES/PARKING ROWS | | | SHALL BE PROVIDED ON THE PLANS. THE DIMENSIONS SHALL | | | INCLUDE THE DIMENSIONS FROM THE COLUMNS. | | | | | | 14) THE DIMENSIONS FOR ALL THE DRIVE AISLES SHALL BE | | | SHOWN ON THE PLANS. | | | | | | 15) THE PLANS SHOW THE GARBAGE AND MOVING TRUCKS | | | EXITING THE SITE VIA THE SAME ONE-WAY DRIVE AISLE WHICH | | | THEY ENTER, JUST IN A REVERSE FLOW. FOR SAFETY REASONS | | | THIS IS NOT PERMITTED. THE TRUCKS SHALL USE TWO CLEARLY | | | MARKED, SEPARATE LANES. | | | | | | 16) THE AUTOTURN PLAN SHOWS THE TRUCKS SWINGING INTO | | | THE OPPOSITE LANE OF TRAFFIC BEFORE ENTERING THE SITE | | | (AND EXITING THE SITE FOR THE GARBAGE TRUCK) WHICH IS | | | NOT PERMITTED. | | | | | | 17) THE AUTOTURN PLAN SHOWS THE SU-40 TRUCKS RUNNING | | | OVER THE CURB IN A FEW LOCATIONS. THIS IS NOT | | | PERMITTED. PLEASE CORRECT. | | | | | | 18) THE EASTERN MOST DRIVE WAY IS SHOWN WITH AN EGRESS | | | ARROW; HOWEVER, ITS WIDTH AND PROXIMITY TO THE VALET | | | ENTRANCE TO THE PARKING AREA ENCOURAGE ITS USE AS AN | | | ENTRY POINT TO THE GARAGE. THIS EGRESS POINT SHALL BE | | | REDESIGNED TO DISCOURAGE ENTRY TO THE GARAGE. IF IT IS | | | LEFT IN ITS CURRENT CONFIGURATION, STAFF WILL HAVE TO | | | COUNT IT AS AN ADDITIONAL ACCESS POINT. THIS WOULD | | | EXCEED THE PERMITTED TWO ACCESS POINTS TO A PUBLIC | | | RIGHT-OF-WAY, WHICH REQUIRES A CITY COMMISSION WAIVER | | | AS A MAJOR PLANNED DEVELOPMENT AMENDMENT. | | | | | | 19) THERE SHALL BE AT LEAST TWO BICYCLE RACKS (FOUR | | | BICYCLE PARKING SPACES) PROVIDED NEAR THE ENTRANCE TO | | | THE BUILDING IN ACCORDANCE WITH SECTION 94-485(Q). | | | | | | 20) PLEASE DEMONSTRATE HOW THE REMAINDER OF THE | | | REQUIRED BICYCLE PARKING SPACES (MINIMUM SIX BICYCLES) | | | WILL MEET CITY BICYCLE PARKING SIZE REQUIREMENTS AND | | | FIT IN THE BICYCLE STORAGE AREA. PLEASE NOTE THAT STAFF | | | RECOMMENDS PROVIDING ENOUGH SPACE TO HOUSE MORE THAN | | | SIX BICYCLES. | | | | | | 21) PLEASE PROVIDE VERIFICATION THAT THE PROPOSED PLAN | | | WIDENS THE ARKONA COURT TRAVEL LANE TO 22 FEET ADJACENT | | | TO THE PROPERTY AS REQUIRED BY THE APPROVED MODERN RPD | | | PLAN. | | | | | | 22) SECTION 94-485(J)(1) PROHIBITS PARKING | | | CONFIGURATIONS WHICH REQUIRE BACKING DIRECTLY ONTO A | | | STREET, SO THE EIGHT ANGLED PARKING SPACES ARE NOT | | | PERMITTED. THE CITY COMMISSION APPROVED 11 PARALLEL | | | PARKING SPACES ALONG ARKONA COURT. ALTERNATIVE | | | CONFIGURATIONS OR NUMBER OF SPACES REQUIRE APPROVAL AS | | | A MAJOR AMENDMENT BY THE CITY COMMISSION. | | | | | | 23) PLEASE VERIFY WITH THE CITY'S ENGINEERING SERVICES | | | DIVISION THAT ON-STREET PARKING SPACE NO. 11 IS A | | | SUFFICIENT DISTANCE FROM FLAGLER DRIVE. | | | | | | 24) ALL REQUIRED FIRE HYDRANTS SHALL BE CLEARLY SHOWN | | | AND LABELED ON THE SITE AND LANDSCAPE PLANS. THE | | | PROPOSED LANDSCAPE SHALL BE ADJUSTED TO COMPLY WITH | | | HYDRANT SETBACK REQUIREMENTS. | | | | | | 25) PLEASE PROVIDE LIGHTING LOCATIONS, INCLUDING POLE | | | DETAILS, AND PHOTOMETRIC PLANS AT THIS TIME SO THAT | | | ZONING STAFF CAN REVIEW. | | | | | | 26) PROVIDE CROSS SECTIONS OF THE BUFFERS SHOWING THE | | | SPECIFIC LANDSCAPE THAT IS PROPOSED AND ANY GRADE | | | VARIATIONS. THE ELEVATION DRAWINGS WITH ELEVATIONS DO | | | NOT PROVIDE ENOUGH DETAIL OR ACCURATE CONDITIONS - EX. | | | THE SOUTHERN PERIMETER SWALE. | | | | | | 27) PROVIDE BETTER DETAILS ON WHAT THE EXTERIOR FACADE | | | OF THE PEDESTAL WILL LOOK LIKE FROM THE EXTERIOR | | | PROPERTIES AND RIGHTS-OF-WAY. | | | |
|
|
| |