Plan Review Details - Project Z16030009
| Plan Review Stops For Project Z16030009 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
04-14-2016 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
04-14-2016 |
Time |
00:21 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
04-14-2016 |
Time |
00:21 |
Sent To |
|
|
| Notes |
| 2016-04-14 00:23:17 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL | | | SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS | | | WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND | | | OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA | | | BUILDING CODE | | | | | | 3. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH | | | ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND | | | OPENING PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 OF | | | THE FLORIDA BUILDING CODE SHALL BE VERIFIED. | | | | | | 4. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 5. THIS PROJECT WILL BE SUBJECT TO ART IN PUBLIC PLACES | | | (AIPP) ASSESSMENT. FOR ADVICE ON THE PROVISION OF | | | PUBLIC ARTWORK IN LIEU OF THE AIPP ASSESSMENT, CONTACT | | | SYBILLE WELTER, ART IN PUBLIC PLACES COORDINATOR, AT | | | (561) 822-1521, OR BY EMAIL: [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
05-09-2016 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
05-09-2016 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
05-09-2016 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-05-09 11:57:34 | COMMENTS ARE BASED ON THE MAY 2, 2016 ROUTING OF | | | REVISED PLANS AND RESPONSES. | | | | | | SITE PLAN IS APPROVED CONDITIONED ON THE REVISING THE | | | PLANS PER THE FOLLOWING: | | | 1. MILLING AND RESURFACING LIMITS FOR TRENCH CUTS ON | | | CITY STREETS IS FULL LANE WIDTH FOR THE TRAVEL LANE(S) | | | ENCROACHED BY THE TRENCH AREA INCLUDING A TRANSITION | | | AREA OF 50 FEET ON EACH SIDE OF THE TRENCH (SEE NOTE 2 | | | ON STANDARD DETAIL P-4 ON SHEET C-3). | | | | | | 2. THE CROSS SECTION FOR THE DRY DETENTION AREA SHOWS A | | | SIDE SLOPE OF 4:1 MAX. SHEET C-1 SHOWS AN SIDE SLOPE OF | | | 8:1 BETWEEN THE TOP OF SLOPE LINE AND TOE OF SLOPE | | | LINE. DRAINAGE STORAGE CALCULATIONS SHOULD BE BASED ON | | | WHAT WILL BE CONSTRUCTED. | | | | | | 3. BASED ON THE DISTANCE BETWEEN LANDSCAPE ISLANDS IN | | | THE PROPOSED PARKING LOT, THE PARKING SPACE WIDTHS | | | APPEAR TO BE WIDER THAN THE 8' 6" SHOWN ON DETAIL E ON | | | SHEET A-100. | | | | | | 4. THE LANDSCAPE PLANS CALL OUT A PROPOSED 1-STORY | | | BUILDING ADDITION. | | | | | | TRACY L. WARD, P.E. | | | SR. STORMWATER ENGINEER | | | ENGINEERING SERVICES DEPARTMENT | | | 561-494-1120 |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
04-11-2016 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
04-11-2016 |
Time |
08:19 |
Rev Time |
|
| Received By |
tward |
Date |
04-11-2016 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-04-11 08:19:36 | CITY OF WEST PALM BEACH | | | PUBLIC WORKS DEPARTMENT | | | | | | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL: | | | | | | 1. PLEASE SUBMIT ESTIMATES FOR THE PEAK POTABLE WATER | | | DEMAND, SANITARY SEWER FLOW, AND SOLID WASTE COLLECTION | | | YARDAGE. | | | | | | 2. DETAILS SHEETS WILL NEED TO UTILIZE STANDARD CITY OF | | | WEST PALM BEACH DETAILS, WHICH MAY BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 3. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE | | | AVAILABLE AT HTTP://WWW.CO.PALM-BEACH.FL.US/NEWSROOM/08 | | | 14/08-26-14-FLOOD_MAPS.HTM. PLEASE REVIEW THE MAPS AND | | | VERIFY THAT THE NEW MAPS WILL NOT IMPACT THE PROPOSED | | | PROJECT. | | | | | | 4. PLEASE SHOW THE SIGHT TRIANGLES ON THE LANDSCAPING | | | PLANS FOR THE INTERSECTIONS AND VEHICULAR EXITS. | | | (SECTION 94.305E, CODE OF ORDINANCES) | | | | | | 5. PLEASE COORDINATE WITH THE CITY ENGINEERING STAFF | | | (LAURA LE) FOR THE PROPOSED UTILITY TIE IN LOCATIONS. | | | THE AGE AND CONDITION OF THE EXISTING PIPES MAY NOT BE | | | ADEQUATE FOR THE PROPOSED CONNECTIONS. | | | | | | 6. INDICATE MILLING AND RESURFACING LIMITS AROUND | | | TRENCH CUTS ON CITY STREETS. | | | | | | 7. PLEASE ALSO SHOW THE LOCATIONS OF ROOF DRAINS AND | | | INDICATE WHERE THE DISCHARGE WILL BE DIRECTED. RUNOFF | | | VELOCITY AND VOLUME SHOULD NOT EXCEED EXISTING | | | CONDITIONS. | | | | | | 8. CHECK CALLOUT FOR FIRE DEPARTMENT CONNECTION ON | | | SHEETS LP.1 AND C-2. | | | | | | 9. CONFIRM THE PROPOSED DRY DETENTION AREA WILL HAVE A | | | TOP OR A TOE OF SLOPE ELEVATION OF 13.00 ON SHEET C-1. | | | | | | 10. PROVIDE A CROSS SECTION OF THE DRY DETENTION AREA. | | | | | | 11. SEWER SERVICE LATERALS SHOULD HAVE MINIMUM SLOPE OF | | | 1% (AS OPPOSED TO 1% MAXIMUM SLOPE) ON SHEET C-2. | | | | | | 12. THE ARCHITECTURAL PLANS SHOW A SECOND FLOOR PLAN. | | | THE ENGINEERING AND LANDSCAPE PLANS CALLOUT A PROPOSED | | | ONE STORY ADDITION. | | | | | | 13. ENGINEERING PLANS WERE NOT SIGNED AND SEALED. | | | | | | 14. ROOT BARRIERS MAY BE REQUIRED WHERE PLANTINGS ARE | | | NEAR UNDERGROUND STORMWATER, SANITARY, OR POTABLE WATER | | | LINES. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING DIVISION OF THE PUBLIC | | | WORKS DEPARTMENT. THE ENGINEERING DEVELOPMENT APPROVAL | | | APPLICATION FORMS CAN BE DOWNLOADED AT: | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 2. SOLID WASTE YARDAGE WILL NEED TO BE VERIFIED AS PART | | | OF THE FINAL DESIGN TO VERIFY THAT THE DESIGN INCLUDES | | | APPROPRIATE NUMBER AND SIZE OF TRASH BINS. | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | 561-494-1120 | | | [email protected] | | | | | | KELLY CRANFORD, P.E. | | | CAPITAL IMPROVEMENT PLAN MANAGER | | | [email protected] | | | 561-494-1098 (OFFICE) | | | | | | VINCE NOEL, PSM | | | CITY SURVEYOR / REAL ESTATE SUPERVISOR | | | [email protected] | | | 561-494-1096 | | | | | | BRIAN COLLINS, PE | | | CITY TRAFFIC ENGINEER | | | [email protected] | | | 561-494-1040 | | | | | | LAURA LE, PE | | | PUBLIC UTILITIES ENGINEER | | | 561-494-1093 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
04-07-2016 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
04-07-2016 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
04-07-2016 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2016-04-07 15:26:59 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM IS | | | REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP DRAWINGS, | | | ARE REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY | | | THE FIRE PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | | | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | 7. A CLASS ?A? NFPA 72 COMPLIANT MONITORED FIRE ALARM | | | SYSTEM IS REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP | | | DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED AND | | | APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY | | | INSTALLATION. | | | | | | 8. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 9. THE PROPOSED PRIVATE FIRE HYDRANT AND UNDERGROUND | | | FIRE LINES SHALL COMPLY WITH NFPA 24 AND SHALL BE | | | PERMITTED UNDER SEPARATE SHOP DRAWINGS AND INSPECTED BY | | | A FIRE INSPECTOR PRIOR TO BE COVERED OVER. | | | | | | 10. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 11. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
06-03-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
06-03-2016 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
06-03-2016 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2016-06-03 13:54:28 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: FPL DISTRIBUTION CONTROL CENTER EXPANSION | | | Z16030009 | | | JUNE 3, 2016 | | | STAFF HAS REVIEWED THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS FOR THE ABOVE REFERENCED PETITION AND | | | PROVIDES THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PLEASE PROVIDE A TREE DISPOSITION AND | | | MITIGATION CHART FOR ALL EXISTING TREES AND PALMS, | | | IDENTIFY EACH BY SPECIES, AND INDICATE IF THEY WILL BE | | | RELOCATED, REMOVED, OR REMAIN IN PLACE TO SHOW | | | COMPLIANCE WITH SECTION 94-448. | | | | | | 2. SATISFIED. PLEASE CORRECT THE CALCULATIONS FOR | | | REQUIRED SHADE TREES, FLOWERING TREES AND SHRUBS USING | | | THE REQUIRED 40% OPEN SPACE OF THE ENTIRE SITE. | | | | | | 3. SATISFIED. PLEASE CORRECT THE CALCULATIONS TO SHOW | | | COMPLIANCE WITH THE 20% LINEAR FEET LANDSCAPED EXTERIOR | | | REQUIRED FOR ALL INDUSTRIAL STRUCTURES PER SECTION | | | 94-443 (E)(2). | | | | | | 4. SATISFIED. PER 94-443 (B)(1). PLEASE SHOW A 5 FOOT | | | LANDSCAPE BUFFER AROUND THE EAST, NORTH AND WEST | | | PROPERTY LINES, AND A 10 FOOT LANDSCAPE BUFFER ADJACENT | | | TO UP THE GROVE LANE. | | | | | | 5. SATISFIED. PLEASE PROVIDE CALCULATIONS FOR ALL | | | BUFFERS FOR REQUIRED SHADE TREES PER 94-443(B) (4) AND | | | (5), AND PROVIDE ON THE LANDSCAPE PLAN. | | | | | | 6. SATISFIED. PLEASE ADD TREES AND PROVIDE LANDSCAPE | | | AREAS AT LEAST 5 FEET IN WIDTH AT THE END OF EACH ROW | | | OF PARKING PER SECTION 94-443 (C). | | | | | | 7. SATISFIED. PLEASE PROVIDE CALCULATIONS TO SHOW | | | COMPLIANCE WITH SECTION 94-443 (C)(3) AND (4) FOR THE | | | LANDSCAPE AREAS WITHIN THE PARKING AND PAVED AREAS. | | | | | | 8. SATISFIED. PLEASE PROVIDE THE HEIGHT SPECIFICATIONS | | | FOR ALL TREES ON THE PLANT LIST. ALL PLANTS MUST BE | | | FLORIDA GRADE 1 OR BETTER. | | | | | | 9. SATISFIED. PLEASE PROVIDE THE WATER NEEDS CATEGORY | | | FOR EACH SPECIES ON THE PLANT LIST FROM THE SFWMD | | | WATERWISE GUIDE TO SHOW COMPLIANCE WITH FLORIDA | | | FRIENDLY LANDSCAPING PER 94-442 (G). | | | | | | 10. SATISFIED. PLEASE REVISE THE LANDSCAPE AND | | | ENGINEERING PLANS TO AVOID CONFLICTS BETWEEN | | | LANDSCAPING AND WATER, SEWER, DRAINAGE, LIGHTING AND | | | FPL EQUIPMENT. PLEASE SHOW LOCATIONS OF ALL UTILITIES | | | AND EASEMENTS CLEARLY LABEL THEM ON THE LANDSCAPE PLAN. | | | | | | 11. SATISFIED. PLEASE INCLUDE A ROOT BARRIER DETAIL AND | | | SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT | | | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES | | | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY | | | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 12. SATISFIED. PLEASE SHOW LOCATIONS OF MECHANICAL | | | EQUIPMENT SUCH AS A/C COMPRESSORS, ETC., AND PROVIDE | | | SCREENING FOR ALL GROUND MOUNTED EQUIPMENT AND | | | UTILITIES. | | | | | | ADDITIONAL COMMENTS 5/18: | | | 13. SATISFIED. PLEASE CORRECT TO SHOW SQUARE FOOTAGE OF | | | 40% OPEN SPACE IN THE REQUIRED COLUMN IN THE DATA | | | TABLE, AND PROVIDED SQUARE FOOTAGE IN THE PROPOSED | | | COLUMN ON SHEET LP-1. | | | | | | 14. SATISFIED. PLEASE CORRECT THE BUFFER REQUIREMENTS | | | IN THE DATA TABLE TO SHOW A 5 FOOT BUFFER REQUIRED IN | | | ALL AREAS EXCEPT THE 10 FOOT REQUIRED ADJACENT TO UP | | | THE GROVE LANE. | | | | | | 15. SATISFIED. PLEASE PROVIDE TREES AND HEDGE AS | | | REQUIRED AT THE SOUTH END OF THE EASTERN LANDSCAPE | | | BUFFER AND ADJACENT SOUTH BUFFER. | | | | | | 16. SATISFIED. PLEASE PROVIDE TREES IN THE TERMINAL | | | ISLANDS AND LANDSCAPE DIVIDER ISLANDS IN THE PARKING | | | AREAS IN THE FOLLOWING LOCATIONS: | | | ? 4 LOCATIONS ALONG THE NORTH END OF THE EASTERN | | | PARKING AREA | | | ? TERMINAL ISLAND CREATED IN SOUTHWEST CORNER OF | | | EASTERN PARKING AREA | | | | | | 17. SATISFIED. CREATE TERMINAL LANDSCAPE ISLANDS AT THE | | | END OF PARKING ROWS ADJACENT TO THE FRONT ENTRANCE OF | | | THE NEW BUILDING AND ADD REQUIRED TREES. | | | | | | 18. SATISFIED. PLEASE IDENTIFY THE VARIETY OF CRAPE | | | MYRTLE ON THE PLANT LIST. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. ALL INVASIVE EXOTIC PLANT SPECIES SHALL BE REMOVED | | | FROM THE ENTIRE SITE PRIOR TO ISSUANCE OF A CERTIFICATE | | | OF OCCUPANCY FOR THE NEW BUILDING. | | | 3. PRIOR TO THE ISSUANCE OF THE LANDSCAPE PERMIT FOR | | | THE IMPROVEMENTS TO THE SITE, THE LANDSCAPE PLAN WILL | | | BE REVISED TO SUBSTITUTE NATIVE FLOWERING TREES IN | | | PLACE OF THE CRAPE MYRTLES ALONG THE NORTHERN BUFFER. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
05-19-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
05-19-2016 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
05-19-2016 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2016-05-19 13:29:05 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: FPL DISTRIBUTION CONTROL CENTER EXPANSION | | | Z16030009 | | | MAY 18, 2016 | | | STAFF HAS REVIEWED THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS FOR THE ABOVE REFERENCED PETITION AND | | | PROVIDES THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PLEASE PROVIDE A TREE DISPOSITION AND | | | MITIGATION CHART FOR ALL EXISTING TREES AND PALMS, | | | IDENTIFY EACH BY SPECIES, AND INDICATE IF THEY WILL BE | | | RELOCATED, REMOVED, OR REMAIN IN PLACE TO SHOW | | | COMPLIANCE WITH SECTION 94-448. | | | | | | 2. SATISFIED. PLEASE CORRECT THE CALCULATIONS FOR | | | REQUIRED SHADE TREES, FLOWERING TREES AND SHRUBS USING | | | THE REQUIRED 40% OPEN SPACE OF THE ENTIRE SITE. | | | | | | 3. SATISFIED. PLEASE CORRECT THE CALCULATIONS TO SHOW | | | COMPLIANCE WITH THE 20% LINEAR FEET LANDSCAPED EXTERIOR | | | REQUIRED FOR ALL INDUSTRIAL STRUCTURES PER SECTION | | | 94-443 (E)(2). | | | | | | 4. SATISFIED. PER 94-443 (B)(1). PLEASE SHOW A 5 FOOT | | | LANDSCAPE BUFFER AROUND THE EAST, NORTH AND WEST | | | PROPERTY LINES, AND A 10 FOOT LANDSCAPE BUFFER ADJACENT | | | TO UP THE GROVE LANE. | | | | | | 5. SATISFIED. PLEASE PROVIDE CALCULATIONS FOR ALL | | | BUFFERS FOR REQUIRED SHADE TREES PER 94-443(B) (4) AND | | | (5), AND PROVIDE ON THE LANDSCAPE PLAN. | | | | | | 6. SATISFIED. PLEASE ADD TREES AND PROVIDE LANDSCAPE | | | AREAS AT LEAST 5 FEET IN WIDTH AT THE END OF EACH ROW | | | OF PARKING PER SECTION 94-443 (C). | | | | | | 7. SATISFIED. PLEASE PROVIDE CALCULATIONS TO SHOW | | | COMPLIANCE WITH SECTION 94-443 (C)(3) AND (4) FOR THE | | | LANDSCAPE AREAS WITHIN THE PARKING AND PAVED AREAS. | | | | | | 8. SATISFIED. PLEASE PROVIDE THE HEIGHT SPECIFICATIONS | | | FOR ALL TREES ON THE PLANT LIST. ALL PLANTS MUST BE | | | FLORIDA GRADE 1 OR BETTER. | | | | | | 9. SATISFIED. PLEASE PROVIDE THE WATER NEEDS CATEGORY | | | FOR EACH SPECIES ON THE PLANT LIST FROM THE SFWMD | | | WATERWISE GUIDE TO SHOW COMPLIANCE WITH FLORIDA | | | FRIENDLY LANDSCAPING PER 94-442 (G). | | | | | | 10. SATISFIED. PLEASE REVISE THE LANDSCAPE AND | | | ENGINEERING PLANS TO AVOID CONFLICTS BETWEEN | | | LANDSCAPING AND WATER, SEWER, DRAINAGE, LIGHTING AND | | | FPL EQUIPMENT. PLEASE SHOW LOCATIONS OF ALL UTILITIES | | | AND EASEMENTS CLEARLY LABEL THEM ON THE LANDSCAPE PLAN. | | | | | | 11. SATISFIED. PLEASE INCLUDE A ROOT BARRIER DETAIL AND | | | SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT | | | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES | | | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY | | | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 12. SATISFIED. PLEASE SHOW LOCATIONS OF MECHANICAL | | | EQUIPMENT SUCH AS A/C COMPRESSORS, ETC., AND PROVIDE | | | SCREENING FOR ALL GROUND MOUNTED EQUIPMENT AND | | | UTILITIES. | | | | | | ADDITIONAL COMMENTS 5/18: | | | 13. PLEASE CORRECT TO SHOW SQUARE FOOTAGE OF 40% OPEN | | | SPACE IN THE REQUIRED COLUMN IN THE DATA TABLE, AND | | | PROVIDED SQUARE FOOTAGE IN THE PROPOSED COLUMN ON SHEET | | | LP-1. | | | | | | 14. PLEASE CORRECT THE BUFFER REQUIREMENTS IN THE DATA | | | TABLE TO SHOW A 5 FOOT BUFFER REQUIRED IN ALL AREAS | | | EXCEPT THE 10 FOOT REQUIRED ADJACENT TO UP THE GROVE | | | LANE. | | | | | | 15. PLEASE PROVIDE TREES AND HEDGE AS REQUIRED AT THE | | | SOUTH END OF THE EASTERN LANDSCAPE BUFFER AND ADJACENT | | | SOUTH BUFFER. | | | | | | 16. PLEASE PROVIDE TREES IN THE TERMINAL ISLANDS AND | | | LANDSCAPE DIVIDER ISLANDS IN THE PARKING AREAS IN THE | | | FOLLOWING LOCATIONS: | | | ? 4 LOCATIONS ALONG THE NORTH END OF THE EASTERN | | | PARKING AREA | | | ? TERMINAL ISLAND CREATED IN SOUTHWEST CORNER OF | | | EASTERN PARKING AREA | | | | | | 17. CREATE TERMINAL LANDSCAPE ISLANDS AT THE END OF | | | PARKING ROWS ADJACENT TO THE FRONT ENTRANCE OF THE NEW | | | BUILDING AND ADD REQUIRED TREES. | | | | | | 18. PLEASE IDENTIFY THE VARIETY OF CRAPE MYRTLE ON THE | | | PLANT LIST. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. ALL INVASIVE EXOTIC PLANT SPECIES SHALL BE REMOVED | | | FROM THE ENTIRE SITE PRIOR TO ISSUANCE OF A CERTIFICATE | | | OF OCCUPANCY FOR THE NEW BUILDING. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
04-11-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
04-11-2016 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
04-11-2016 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2016-04-11 15:01:45 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: FPL DISTRIBUTION CONTROL CENTER EXPANSION | | | Z16030009 | | | APRIL 11, 2016 | | | STAFF HAS REVIEWED THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS FOR THE ABOVE REFERENCED PETITION AND | | | PROVIDES THE FOLLOWING COMMENTS: | | | | | | 1. PLEASE PROVIDE A TREE DISPOSITION AND MITIGATION | | | CHART FOR ALL EXISTING TREES AND PALMS, IDENTIFY EACH | | | BY SPECIES, AND INDICATE IF THEY WILL BE RELOCATED, | | | REMOVED, OR REMAIN IN PLACE TO SHOW COMPLIANCE WITH | | | SECTION 94-448. | | | | | | 2. PLEASE CORRECT THE CALCULATIONS FOR REQUIRED SHADE | | | TREES, FLOWERING TREES AND SHRUBS USING THE REQUIRED | | | 40% OPEN SPACE OF THE ENTIRE SITE. | | | | | | 3. PLEASE CORRECT THE CALCULATIONS TO SHOW COMPLIANCE | | | WITH THE 20% LINEAR FEET LANDSCAPED EXTERIOR REQUIRED | | | FOR ALL INDUSTRIAL STRUCTURES PER SECTION 94-443 | | | (E)(2). | | | | | | 4. PER 94-443 (B)(1). PLEASE SHOW A 5 FOOT LANDSCAPE | | | BUFFER AROUND THE EAST, NORTH AND WEST PROPERTY LINES, | | | AND A 10 FOOT LANDSCAPE BUFFER ADJACENT TO UP THE GROVE | | | LANE. | | | | | | 5. PLEASE PROVIDE CALCULATIONS FOR ALL BUFFERS FOR | | | REQUIRED SHADE TREES PER 94-443(B) (4) AND (5), AND | | | PROVIDE ON THE LANDSCAPE PLAN. | | | | | | 6. PLEASE ADD TREES AND PROVIDE LANDSCAPE AREAS AT | | | LEAST 5 FEET IN WIDTH AT THE END OF EACH ROW OF PARKING | | | PER SECTION 94-443 (C). | | | | | | 7. PLEASE PROVIDE CALCULATIONS TO SHOW COMPLIANCE WITH | | | SECTION 94-443 (C)(3) AND (4) FOR THE LANDSCAPE AREAS | | | WITHIN THE PARKING AND PAVED AREAS. | | | | | | 8. PLEASE PROVIDE THE HEIGHT SPECIFICATIONS FOR ALL | | | TREES ON THE PLANT LIST. ALL PLANTS MUST BE FLORIDA | | | GRADE 1 OR BETTER. | | | | | | 9. PLEASE PROVIDE THE WATER NEEDS CATEGORY FOR EACH | | | SPECIES ON THE PLANT LIST FROM THE SFWMD WATERWISE | | | GUIDE TO SHOW COMPLIANCE WITH FLORIDA FRIENDLY | | | LANDSCAPING PER 94-442 (G). | | | | | | 10. PLEASE REVISE THE LANDSCAPE AND ENGINEERING PLANS | | | TO AVOID CONFLICTS BETWEEN LANDSCAPING AND WATER, | | | SEWER, DRAINAGE, LIGHTING AND FPL EQUIPMENT. PLEASE | | | SHOW LOCATIONS OF ALL UTILITIES AND EASEMENTS CLEARLY | | | LABEL THEM ON THE LANDSCAPE PLAN. | | | | | | 11. PLEASE INCLUDE A ROOT BARRIER DETAIL AND SHOW | | | LOCATIONS OF ROOT BARRIERS TO PROTECT INFRASTRUCTURE | | | AND TREES FROM CONFLICTS. THIS INCLUDES WATER, SEWER, | | | DRAINAGE, SIDEWALKS AND CURBS, AND ANY FIELD STRUCTURES | | | THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 12. PLEASE SHOW LOCATIONS OF MECHANICAL EQUIPMENT SUCH | | | AS A/C COMPRESSORS, ETC., AND PROVIDE SCREENING FOR ALL | | | GROUND MOUNTED EQUIPMENT AND UTILITIES. | | | | | | | | | | | | | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. ALL INVASIVE EXOTIC PLANT SPECIES SHALL BE REMOVED | | | FROM THE ENTIRE SITE PRIOR TO ISSUANCE OF A CERTIFICATE | | | OF OCCUPANCY FOR THE NEW BUILDING. | | | |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
3 |
Status |
P |
Date |
05-11-2016 |
|
|
Cont ID |
|
| Sent By |
lle |
Date |
05-11-2016 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
lle |
Date |
05-11-2016 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
1 |
Status |
F |
Date |
04-11-2016 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
04-11-2016 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
lle |
Date |
04-11-2016 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-04-13 00:00:48 | GENERAL COMMENTS FROM PU CUSTOMER SERVICE (S. HUNTER): | | | 1) CALL OUT POINT OF SERVICE; | | | 2) CALL OUT BACKFLOW PREVENTER DEVICE - SIZE & TYPE | | 2016-04-08 16:18:04 | SEE COMMENTS UNDER ENG - PPRC. |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
P |
Date |
05-09-2016 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
05-09-2016 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
05-09-2016 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-05-09 11:59:01 | SEE NOTES UNDER ENG PPRC 2. |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
04-11-2016 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
04-11-2016 |
Time |
08:21 |
Rev Time |
|
| Received By |
tward |
Date |
04-11-2016 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-04-11 08:22:07 | SEE COMMENTS UNDER ENG - PPRC. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
P |
Date |
05-11-2016 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
05-11-2016 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
05-11-2016 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2016-08-03 09:34:49 | PURSUANT TO A MEMO FROM DANIELLE KITTREDGE, SENIOR | | | PLANNER, ALL COMMENTS WERE TO BE INSERTED NO LATER THAN | | | MAY 11, 2016. AS NO COMMENTS WERE RECEIVED PRIOR TO | | | SUCH DEADLINE, IT IS ASSUMMED THAT THE RE-SUBMITTED | | | PLANS HAVE SUFFICIENTLY ADDRESSED ANY PREVIOUS COMMENTS | | | / CONCERNS. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
04-11-2016 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
04-11-2016 |
Time |
08:22 |
Rev Time |
|
| Received By |
tward |
Date |
04-11-2016 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-04-11 08:22:47 | SEE COMMENTS UNDER ENG - PPRC. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
P |
Date |
05-11-2016 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
05-11-2016 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
05-11-2016 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2016-08-03 09:35:26 | PURSUANT TO A MEMO FROM DANIELLE KITTREDGE, SENIOR | | | PLANNER, ALL COMMENTS WERE TO BE INSERTED NO LATER THAN | | | MAY 11, 2016. AS NO COMMENTS WERE RECEIVED PRIOR TO | | | SUCH DEADLINE, IT IS ASSUMMED THAT THE RE-SUBMITTED | | | PLANS HAVE SUFFICIENTLY ADDRESSED ANY PREVIOUS COMMENTS | | | / CONCERNS. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
04-11-2016 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
04-11-2016 |
Time |
08:40 |
Rev Time |
|
| Received By |
tward |
Date |
04-11-2016 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-04-11 08:40:23 | SEE COMMENTS UNDER ENG - PPRC. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
05-05-2016 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
05-05-2016 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
05-05-2016 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2016-05-05 14:41:50 | PLANNING AND ZONING COMMENTS: | | | | | | 5/5/2016 | | | | | | REVISED PLANS ARE APPROVED WITH THE FOLLOWING | | | CONDITIONS : | | | | | | 1. ADA PARKING SPACES ARE CALCULATED BASED ON THE TOTAL | | | NUMBER OF SPACES PROVIDED. IF THE SITE HAS 314 PARKING | | | SPACES, 9 OF THOSE PARKING SPACES MUST BE ADA PARKING | | | SPACES. PLAN INCLUDES 8 ADA SPACES, PLEASE REVISE TO | | | INCLUDE 1 ADDITIONAL ADA PARKING SPACE [ZLDR SEC. | | | 94-485(O)]. | | | | | | 2. CAN THE EQUIPMENT CORRAL BE EXPANDED TO INCLUDE | | | ADDITIONAL MECHANICAL EQUIPMENT LOCATED DIRECTLY TO THE | | | EAST? | | | | | | 3. PROVIDE COMCAST AND AT&T UTILITY LETTERS. | | | | | | 4. PROVIDE REVISED TRAFFIC CONCURRENCY LETTER TO | | | ACCOMODATE THE INCREASE IN BUILDING SQUARE FOOTAGE | | | PRIOR TO PROCEEDING TO CITY COMMISSION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
04-13-2016 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
04-13-2016 |
Time |
11:39 |
Rev Time |
|
| Received By |
dkittred |
Date |
04-13-2016 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-04-13 11:52:27 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 4/13/16 | | | | | | 1. PLEASE PROVIDE UTILITY LETTERS. | | | | | | 2. KEVIN HUGHES SIGNED THE OWNER'S CONSENT FORM FOR | | | FLORIDA POWER & LIGHT COMPANY. IT IS UNCLEAR OF MR. | | | HUGHES' RELATIONSHIP WITH FPL. PLEASE PROVIDE | | | ADDITIONAL DOCUMENTATION AS TO HIS AUTHORIZATION TO | | | SIGN THE APPLICATION. | | | | | | 3. ALL SHEETS SHOW 'FUTURE' BUILDINGS EXCEPT THE | | | OVERALL SITE PLAN (SHEET A-100). IF YOU WANT TO HAVE | | | APPROVAL FOR FUTURE BUILDINGS, THE FUTURE BUILDINGS | | | NEED TO BE INCLUDED ON THE OVERALL SITE PLAN WITH A | | | COLUMN FOR FUTURE EXPANSION/PHASE II INDICATING | | | PROPOSED SQUARE FOOTAGE, FAR, OPEN SPACE, PARKING, ETC. | | | PLEASE NOTE THAT TRANSPORTATION CONCURRENCY LETTER DOES | | | NOT INCLUDE THE FUTURE SQUARE FOOTAGE AND A | | | TRANSPORTATION CONCURRENCY LETTER WILL BE REQUIRED AT | | | TIME OF SUBMITTAL FOR THE CONSTRUCTION OF THE FUTURE | | | EXPANSIONS. | | | | | | 4. TRANSPORTATION CONCURRENCY LETTER IS FOR 68,000 | | | SQUARE FEET OF NEW CONSTRUCTION. THE PROPOSAL SHOWS | | | 71,055 SQUARE FEET OF NEW CONSTRUCTION BE PROPOSED. | | | THESE NUMBERS WILL NEED TO MATCH. PLEASE PROVIDE | | | REVISED LETTER OR UPDATED SITE PLAN. | | | | | | 5. INDICATE HEIGHT AND SETBACK OF PROPOSED LIGHT POLES. | | | THE LIGHT POLES MUST COMPLY WITH THE SETBACKS AND | | | HEIGHT REQUIREMENTS OF THE INDUSTRIAL (I) ZONING | | | DISTRICT. ANY LIGHT POLES WITHIN THE LANDSCAPE BUFFER | | | MUST BE PLACED TO AVOID CONFLICTS WITH TREES. | | | | | | 6. ON SHEET A-100, THE REQUIRED PARKING CALCULATION HAS | | | MANY NUMBERS OVERLAPPING EACH OTHER AND IS UNREADABLE. | | | PLEASE CORRECT SO PARKING NUMBERS CAN BE REVIEWED. | | | | | | 7. PLEASE ROTATE THE NEW BICYCLE PARKING PAD 90 DEGREES | | | SO THAT IT IS PARALLEL TO THE ENTRANCE SIDEWALK TO THE | | | BUILDING. OR YOU MAY SHIFT THE BICYCLE PARKING PAD | | | SOUTH TO MEET UP WITH THE SIDEWALK IN FRONT OF THE ADA | | | SPACES SO SOMEONE DOES NOT HAVE TO CROSS THE GRASS AREA | | | TO ACCESS THE BICYCLE PARKING. | | | | | | 8. PLEASE LABEL ON SITE PLAN NUMBER OF BICYCLE PARKING | | | SPACES ON BOTH THE EXISTING AND PROPOSED BICYCLE | | | PARKING PADS. | | | | | | 9. DIMENSION 'NEW DELIVERY DRIVE'. | | | | | | 10. A LANDSCAPE ISLAND NEEDS TO BE ADDED THE END OF THE | | | LAST PARKING SPOT AT THE ENTRANCE TO THE 'NEW DELIVERY | | | DRIVE.' ALL SHEETS EXCEPT OVERALL SITE PLAN (A-100) | | | SHOW THE TERMINAL LANDSCAPE ISLAND. PLEASE CORRECT AND | | | MAKE SURE ALL BASE LAYERS ARE THE SAME FOR ALL SHEETS. | | | | | | 11. WILL THE EXISTING DUMPSTER ON THE SITE BE | | | SUFFICIENT TO SERVE THE NEW EXPANSION? | | | | | | 12. DIMENSION 'EXISTING ROADWAY' ON THE WESTERN SIDE OF | | | THE PROPERTY AND DRIVEWAY INTO THE PARKING AREA FROM | | | THIS ROAD. | | | | | | 13. INSTALL A MINIMUM 5 FOOT WIDE SIDEWALK ALONG THE | | | PROPERTY FRONTAGE [CITY CODE SEC. 78-8]. | | | | | | 14. PLEASE CLARIFY WHAT WILL OCCUR ON THE NORTHWEST | | | PORTION OF THE PROPERTY. WILL THIS AREA STILL REMAIN | | | OUTDOOR STORAGE OR JUST BE A VEGETATED GREEN SPACE? | | | | | | 15. PLEASE INCLUDE LOCATION OF UTILITY EASEMENTS ON THE | | | OVERALL SITE PLAN SHEET (A-100). | | | | | | 16. ARE THERE ANY FREESTANDING SIGNS BEING PROPOSED? IF | | | SO, PLEASE INDICATE PROPOSED LOCATION TO AVOID CONFLICT | | | WITH LANDSCAPING. | | | | | | GENERAL COMMENT(S): | | | 17. YOU MAY WANT TO CONSIDER THE INSTALLATION OF SOLAR | | | PANELS ON ROOF OF THE STRUCTURE. | | | | | | WHEN RESUBMITTING: | | | A. PROVIDE WRITTEN RESPONSES TO REVIEW COMMENTS MADE BY | | | DEPARTMENTS IN A WRITTEN FORMAT WHEN RESUBMITTING. | | | | | | B. PROVIDE 15 SETS OF REVISED PLANS AND/OR DOCUMENTS | | | ALONG WITH ONE REDUCED COPY AND ELECTRONIC COPY OF ALL | | | PLANS. | | | | | | C. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | D. PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | E. IN ORDER TO BE CONSIDERED FOR THE JUNE 21, 2016 | | | PLANNING BOARD MEETING, ALL PLANS MUST BE REVISED AND | | | SUBMITTED BY APRIL 29, 2016. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | | |
|
|
| |