Plan Review Details - Project Z16020009
| Plan Review Stops For Project Z16020009 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
03-09-2016 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
03-09-2016 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
03-09-2016 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2016-03-09 10:32:02 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. FOR ANY BUILDING CROSSING A PROPERTY LINE, EITHER A | | | RECORDED UNITY OF TITLE, OR SOME OTHER APPROVED LEGAL | | | INSTRUMENT, SHALL BE INCLUDED WITH THE PERMIT | | | APPLICATION, OR THE BUILDING MUST HAVE A FIRE WALL | | | ALONG THE PROPERTY LINE, PER SECTION 202 OF FLORIDA | | | BUILDING CODE, BUILDING, FIRE SEPARATION DISTANCE. | | | | | | 3. PER SECTION 208.2.4 OF FLORIDA ACCESSIBILITY CODE, | | | ONE IN EVERY SIX ACCESSIBLE SPACES (AT LEAST ONE) IN A | | | PARKING STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND | | | DESIGNED IN ACCORDANCE WITH SECTION OF 502 OF FLORIDA | | | ACCESSIBILITY CODE (VERTICAL CLEARANCE NOT LESS THAN 98 | | | INCHES AT SPACE AND VEHICULAR ACCESS ROUTE) | | | | | | 4. THE PLANS FOR LEVELS 2 THROUGH 5 SHALL SHOW THE | | | ACCESSIBLE ROUTE FROM THE ACCESSIBLE PARKING SPACES TO | | | THE ELEVATORS. ACCESSIBLE PARKING SPACE ACCESS AISLES | | | SHALL BE LOCATED SO THAT THE USER IS NOT COMPELLED TO | | | WALK OR WHEEL BEHIND ANOTHER PARKED VEHICLE OR IN THE | | | TRAVEL LANE. THE ACCESS AISLES SHALL ALSO COMPLY WITH | | | THE OTHER PROVISIONS OF SECTION OF 502.3 OF FLORIDA | | | ACCESSIBILITY CODE. | | | | | | 5. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL | | | SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS | | | WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND | | | OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA | | | BUILDING CODE | | | | | | 6. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH | | | ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND | | | OPENING PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 OF | | | THE FLORIDA BUILDING CODE SHALL BE VERIFIED. | | | | | | 7. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES | | | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO | | | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL | | | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE | | | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED | | | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR | | | OTHER APPROVED METHODS. | | | | | | 8. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 9. EACH SEPARATE BUILDING SHALL HAVE A SEPARATE | | | ADDRESS. FOR STREET ADDRESSING, CONTACT MICHAEL ORIO, | | | GIS SUPPORT SPECIALIST, AT (561) 494 1080, OR BY EMAIL: | | | [email protected] | | | | | | 10. THIS PROJECT WILL BE SUBJECT TO ART IN PUBLIC | | | PLACES (AIPP) ASSESSMENT. FOR ADVICE ON THE PROVISION | | | OF PUBLIC ARTWORK IN LIEU OF THE AIPP ASSESSMENT, | | | CONTACT SYBILLE WELTER, ART IN PUBLIC PLACES | | | COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
10-31-2016 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
10-31-2016 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2016-10-31 14:18:36 | IN ADDITION TO PREVIOUS ACKNOWLEDGED COMMENTS: | | | | | | 1. THE AUTOTURN ANALYSIS WAS NOT SHOWN FOR WHERE THE | | | TRASH COLLECTORS ARE BEING LOCATED. ROOM DOES NOT | | | APPEAR LARGE ENOUGH. PLEASE CONTACT FERDINAND RIVERA | | | FOR SANITATION APPROVAL. | | | | | | 2. AS PREVIOUSLY DISCUSSED, A NEW WATER MAIN AND SEWER | | | LINE WILL NEED TO BE RUN FROM THE EAST PROPERTY LIMITS | | | TO CONNECT WITH THE NEW FRONTAGE ROAD ALONG THE FEC. | | | THIS IS A REQUIREMENT FOR THE PROPOSED OVERHEAD AND | | | SUBSURFACE ALLEY IMPROVEMENTS. | | | | | | 3. THE CITY WILL WORK WITH THE APPLICANT ON THE TYPE OF | | | SURFACE REQUIREMENTS FOR THE ALLEY WHEN RESTORED. | | | | | | 4. A PREVIOUS GAS LINE IS NO LONGER SHOWN ON THE | | | PLANS.. IS THERE A GAS LINE IN THE ALLEY? | | | | | | ALL PREVIOUS COMMENTS CONCERNING ADDITIONAL SUBMITTALS | | | AND AGREEMENTS STILL PERTAIN. |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
03-08-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-08-2016 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-08-2016 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2016-03-08 15:51:54 | CITY OF WEST PALM BEACH | | | PUBLIC WORKS DEPARTMENT | | | | | | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL. | | | | | | 1. PLEASE SUBMIT ESTIMATES FOR THE PEAK POTABLE WATER | | | DEMAND, SANITARY SEWER FLOW, AND SOLID WASTE COLLECTION | | | YARDAGE. | | | | | | 2. A MAINTENANCE AGREEMENT WILL BE REQUIRED FOR THE | | | NON-STANDARD ELEMENTS (TREES AND TREE GRATES; PAVERS, | | | ETC.) PROPOSED WITHIN CITY RIGHT-OF-WAY. | | | | | | 3. PLEASE PROVIDE AN AUTOTURN ANALYSIS DEMONSTRATING | | | THE SOLID WASTE COLLECTION VEHICLE CAN ACCESS THE | | | PROPOSED DUMPSTER/COMPACTOR LOCATIONS. THE TRASH | | | DUMPSTER/COMPACTORS MUST LOCATED IN AREAS EASILY | | | SERVICED BY THE CITY SANITATION EQUIPMENT AND MANPOWER | | | PER SECTION 74-35(A)(5) OF THE CODE OF ORDINANCES. IF A | | | ROLL-OFF COMPACTOR IS PROPOSED, PLEASE PROVIDE A LETTER | | | FROM THE PRIVATE PROVIDER VERIFYING THAT THEY CAN | | | PROVIDE SERVICE WITH THE CONFIGURATION SHOWN ON THE | | | PLANS. | | | | | | 4. DETAILS SHEETS WILL NEED TO UTILIZE STANDARD CITY OF | | | WEST PALM BEACH DETAILS, WHICH MAY BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 5. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE | | | AVAILABLE AT HTTP://WWW.CO.PALM-BEACH.FL.US/NEWSROOM/08 | | | 14/08-26-14-FLOOD_MAPS.HTM. PLEASE REVIEW THE MAPS AND | | | VERIFY THAT THE NEW MAPS WILL NOT IMPACT THE PROPOSED | | | PROJECT. | | | | | | 6. PLEASE SHOW THE SIGHT TRIANGLES ON THE GROUND FLOOR | | | LANDSCAPING PLAN FOR THE INTERSECTIONS AND VEHICULAR | | | EXITS. (SECTION 94-305E, CODE OF ORDINANCES) | | | | | | 7. A TRAFFIC STUDY WILL BE REQUIRED FOR THIS PROJECT | | | SHOWING HOW THE PROPOSED DEVELOPMENT WILL AFFECT THE | | | TRAFFIC VOLUME AND SURROUNDING LOCAL ROADWAYS. INCLUDE | | | TRAFFIC ACCIDENT DATA FOR AFFECTED STREET CORRIDORS. | | | ESTIMATE INCREASED OR DECREASED POTENTIAL. SAFETY | | | IMPROVEMENTS SHALL BE RECOMMENDED WHERE NECESSARY. | | | PLEASE SCHEDULE A MEETING WITH THE CITY TRAFFIC | | | ENGINEER (BRIAN COLLINS) TO DETERMINE THE SCOPE OF THE | | | REQUIRED STUDY. | | | | | | 8. PLEASE REVISE THE LANDSCAPE PLAN TO SHOW LOCATIONS | | | OF ALL WATER METERS, VALVES, CLEAN-OUTS, LIGHT POLES, | | | ETC. ROOT BARRIERS MAY BE REQUIRED WHERE PLANTINGS ARE | | | NEAR UNDERGROUND STORMWATER, SANITARY, OR POTABLE WATER | | | LINES. | | | | | | 9. THE AVAILABLE WATER PRESSURE IN THIS PORTION OF THE | | | CITY MAY NOT BE ACCEPTABLE AT ELEVATIONS HIGHER THAN | | | THE 2ND FLOOR. WE RECOMMEND A LONG-TERM PRESSURE STUDY | | | BE PERFORMED PRIOR TO FINALIZATION OF THE UTILITY | | | DESIGN. | | | | | | 10. PLEASE COORDINATE WITH THE CITY ENGINEERING STAFF | | | FOR THE PROPOSED UTILITY TIE IN LOCATIONS. THE AGE AND | | | CONDITION OF THE EXISTING PIPES MAY NOT BE ADEQUATE FOR | | | THE PROPOSED CONNECTIONS. THE SUBMITTED DRAWINGS ARE | | | NOT CONSISTENT WITH PREVIOUS DISCUSSIONS WITH CITY | | | STAFF. | | | | | | 11. PLEASE CLARIFY THE SIZE OF THE EXISTING WATER MAIN. | | | IT IS SHOWN AS A 10? EXISTING MAIN, BUT A 12? X 8? | | | TAPPING SLEEVE. THE MAIN NORTH OF THE DRIVEWAY IS SHOWN | | | AS A 12?, BUT AS A 10? MAIN AT THE PROPOSED CONNECTION | | | LOCATION. | | | | | | 12. PLEASE SHOW THE LOCATIONS OF ROOF DRAINS AND | | | INDICATE WHERE THE DISCHARGE WILL BE DIRECTED. RUNOFF | | | VELOCITY AND VOLUME SHOULD NOT EXCEED EXISTING | | | CONDITIONS. | | | | | | 13. INDICATE MILLING AND RESURFACING LIMITS AROUND | | | TRENCH CUTS ON CITY STREETS. PAVERS WITHIN THE ROSEMARY | | | RIGHT-OF-WAY WILL NEED TO BE RESTORED. | | | | | | 14. A PORTION OF THE PROPERTY ALONG DATURA WILL BE | | | DEDICATED TO THE CITY. | | | | | | 15. PROPOSED WATER MAIN IN THE ALLEY APPEARS TO BE IN | | | CONFLICT WITH AN EXISTING GAS MAIN. | | | | | | 16. THE SFWMD EXFILTRATION TRENCH EQUATION IS NOT | | | APPLICABLE FOR THE DESIGN CONDITIONS OF THE TRENCH | | | LAYOUT. | | | | | | 17. EACH BUILDING SHOULD HAVE ITS PROPORTIONATE SHARE | | | OF STORM WATER TREATMENT AND PEAK FLOW ATTENUATION. | | | PLEASE ALSO SHOW THE LOCATIONS OF ROOF DRAINS AND | | | INDICATE WHERE THE DISCHARGE WILL BE DIRECTED. RUNOFF | | | VELOCITY AND VOLUME SHOULD NOT EXCEED EXISTING | | | CONDITIONS. | | | | | | 18. DRAINAGE PLANS SHOW 18? HDPE AND RCP PIPES. BAFFLE | | | DETAIL ON SHEET 03 SHOWS 15? HDPE. PLEASE REVISE SO | | | THEY ARE CONSISTENT. | | | | | | 19. THE EXISTING DRAINAGE CATCH BASIN MAY NEED TO BE | | | REHABILITATED OR REPLACED RATHER THAN CORED AS SHOWN ON | | | SHEET 02 OF 5. | | | | | | 20. VERIFY DRIVE AISLE IS MINIMUM 24 FEET WIDE FOR THE | | | SOUTH BUILDING GROUND FLOOR PARKING LOT OFF OF THE | | | ALLEY | | | | | | 21. TURN AROUND SPACES MUST BE PROVIDED AT THE DEAD | | | ENDS. REVISE THE PARKING LAYOUT TO COMPLY WITH SECTION | | | 94-485 OF THE CODE OF ORDINANCES. | | | | | | 22. PLEASE PROVIDE AN AUTOTURN ANALYSIS SHOWING THE | | | DELIVERY TRUCKS WILL BE ABLE TO UTILIZE THE SHOWING | | | LOADING AREAS. | | | | | | 23. THERE IS NOT AN EXISTING BUILDING EAST OF THE | | | PROPOSED DEVELOPMENT ALONG DATURA. ONLY THE FPL | | | SUBSTATION. | | | | | | 24. AN AGREEMENT FOR AERIAL AND SUBSURFACE | | | ENCROACHMENTS WILL BE REQUIRED. | | | | | | 25. NEW WATER MAIN MAY NEED TO BE EXTENDED EASTWARD. | | | PROVIDE RESULTS OF MEETING WITH CITY | | | OPERATIONS/MAINTENANCE STAFF REGARDING CONDITION OF | | | EXISTING POTABLE WATER AND SANITARY FACILITIES. | | | PORTIONS OF THE EXISTING LINES MAY NEED TO BE SLEEVED | | | OR ENCASED. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING DIVISION OF THE PUBLIC | | | WORKS DEPARTMENT. THE ENGINEERING DEVELOPMENT APPROVAL | | | APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 2. SOLID WASTE YARDAGE WILL NEED TO BE VERIFIED AS PART | | | OF THE FINAL DESIGN TO VERIFY THAT THE DESIGN INCLUDES | | | APPROPRIATE NUMBER AND SIZE OF TRASH BINS. | | | | | | 3. A SEPARATE SUBMITTAL WILL BE REQUIRED TO THE | | | ENGINEERING DIVISION OF THE PUBLIC WORKS DEPARTMENT FOR | | | REPLAT APPROVAL. PLEASE CONTACT VINCE NOEL AT | | | [email protected] TO GET A COPY OF THE PLAT APPLICATION. | | | FINAL PLAT APPROVAL WILL BE BASED ON THE APPROVED SITE | | | PLAN. | | | | | | | | | | | | KELLY CRANFORD, P.E. | | | CAPITAL IMPROVEMENT PLAN MANAGER | | | [email protected] | | | 561-494-1098 (OFFICE) | | | | | | VINCE NOEL, PSM | | | CITY SURVEYOR / REAL ESTATE SUPERVISOR | | | [email protected] | | | 561-494-1096 | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | 561-494-1120 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
01-06-2017 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
01-06-2017 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
01-06-2017 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2017-01-06 13:54:57 | 3RD REVIEW RESPONSE | | | | | | AFTER A REVIEW OF THE PPRC RESPONSE DATED DECEMBER13, | | | 2016, FROM JON E. SCHMIDT AND ASSOCIATES, TO ANA MARIA | | | APONTE, URBAN PLANNER, THE PREVIOUSLY SUBMITTED FIRE | | | PREVENTION BUREAU COMMENTS HAVE BEEN ADDRESSED. | | | | | | THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES | | | NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
09-21-2016 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
09-21-2016 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
09-21-2016 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2016-09-21 11:01:38 | 2ND REVIEW RESPONSE | | | | | | AFTER A REVIEW OF THE PPRC RESPONSE DATED AUGUST 10, | | | 2016, FROM JON E. SCHMIDT AND ASSOCIATES, TO ANA MARIA | | | APONTE, URBAN PLANNER, THE PREVIOUSLY SUBMITTED FIRE | | | PREVENTION BUREAU COMMENTS HAVE BEEN ADDRESSED. | | | | | | THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES | | | NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
02-24-2016 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
02-24-2016 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
02-24-2016 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2016-02-24 16:30:38 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. ALL PARKING STRUCTURES SHALL COMPLY WITH NFPA 88A, | | | PARKING STRUCTURES AND NFPA 101, THE LIFE SAFETY CODE, | | | INCLUDING MORE SPECIFICALLY, CHAPTER 42 STORAGE | | | OCCUPANCIES (PARKING STRUCTURES) | | | | | | 7. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA | | | 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS | | | STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE | | | BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE | | | BEING CONSTRUCTED. SEPARATE SHOP DRAWINGS, ARE REQUIRED | | | TO BE SUBMITTED, REVIEWED AND APPROVED BY THE FIRE | | | PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | | | | | HIGH RISES SHALL HAVE TWO SEPARATE SOURCES OF WATER | | | SUPPLY. | | | | | | PER NFPA 14 SECTION 7.12.2, HIGH-RISE BUILDINGS SHALL | | | HAVE AT LEAST TWO REMOTELY LOCATED FIRE DEPARTMENT | | | CONNECTIONS FOR EACH ZONE. | | | | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | FOR THE PROPOSED FIRE PUMP(S) , WHAT IS(ARE) THE | | | PRIMARY AND SECONDARY POWER SOURCES? | | | | | | 8. A CLASS ?A? NFPA 72 COMPLIANT MONITORED FIRE ALARM | | | SYSTEM IS REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP | | | DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED AND | | | APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY | | | INSTALLATION. | | | | | | 9. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM. | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER?S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 10. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 11. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | ALL NEW FIRE HYDRANTS AND FDC?S PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLOSELY COORDINATED WITH THE | | | BUREAU OF FIRE PREVENTION. PROPOSED FIRE HYDRANTS AND | | | FDC?S SHOULD BE LOCATED ON THE SAME SIDE OF THE STREET | | | OR ACCESS ROADWAY TO ALLOW FREE ACCESS FOR OTHER | | | ARRIVING EMERGENCY VEHICLES. | | | | | | 12. COMMAND ROOM | | | | | | THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | 1. SHALL BE A MINIMUM OF 200 FT SQUARED WITH A MINIMUM | | | DIMENSION OF 10 FT. | | | 2. THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | 3. A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | 4. SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS AND THE LOCATION | | | OF FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS | | | 5. A WORK TABLE. | | | 6. IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | 7. THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | 8. ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION OF | | | THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | 9. STATUS INDICATORS AND CONTROLS FOR AIR DISTRIBUTION | | | SYSTEMS. | | | 10. CONTROLS FOR UNLOCKING STAIRWAY DOORS | | | SIMULTANEOUSLY | | | 11. SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | 12. EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | 13. FIRE PUMP STATUS INDICATORS | | | 14. GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | 15. PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | 16. CONTROLS REQUIRED FOR SMOKE CONTROL | | | 17. ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1. | | | 18. ELEVATOR EMERGENCY OR STANDBY POWER SELECTOR | | | SWITCH(ES), WHERE EMERGENCY OR STANDBY POWER IS | | | PROVIDED | | | | | | 13. RADIO | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | MAINTAIN A MINIMUM RADIO SIGNAL STRENGTH OF 102.0 DBM | | | FOR THE RADIO SYSTEM USED BY WEST PALM BEACH FIRE | | | RESCUE. IF THE MINIMUM CANNOT BE MAINTAINED, A | | | BI-DIRECTIONAL AMPLIFIED SYSTEM SHALL BE INSTALLED WITH | | | A MINIMUM 2-HOUR RUN TIME BATTERY BACK-UP. | | | | | | 14. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | | BUILDING. | | | ANY GATES SHALL BE PROVIDED WITH KNOX KEY ACCESS LOCKS, | | | PADLOCKS AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 15. THE SMOKE CONTROL SYSTEM SHALL COMPLY WITH NFPA | | | 101, CHAPTER 9, BUILDING SERVICE AND FIRE PROTECTION | | | EQUIPMENT, INCLUDING: | | | | | | THE SMOKE CONTROL SYSTEMS SHALL BE INSTALLED, | | | INSPECTED, TESTED, AND MAINTAINED IN ACCORDANCE WITH | | | NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS; NFPA 204, | | | STANDARD FOR SMOKE AND HEAT VENTING; OR NATIONALLY | | | RECOGNIZED STANDARDS, ENGINEERING GUIDES, OR | | | RECOMMENDED PRACTICES, AS APPROVED BY THE AUTHORITY | | | HAVING JURISDICTION. | | | | | | THE ENGINEER OF RECORD SHALL CLEARLY IDENTIFY THE | | | INTENT OF THE SYSTEM, THE DESIGN METHOD USED, THE | | | APPROPRIATENESS OF THE METHOD USED, AND THE REQUIRED | | | MEANS OF INSPECTING, TESTING, AND MAINTAINING THE | | | SYSTEM. | | | | | | ACCEPTANCE TESTING SHALL BE PERFORMED BY A SPECIAL | | | INSPECTOR IN ACCORDANCE WITH SECTION 9.9. | | | | | | 16. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 17. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
01-20-2017 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-20-2017 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-20-2017 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2017-01-20 11:43:46 | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: CLEMATIS PLACE Z16020009 | | | JANUARY 20, 2017 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PLEASE REVISE THE OPEN SPACE DIAGRAM AND | | | CALCULATIONS TO SHOW THE REQUIRED 20% TERRACE PRIVATE | | | OPEN SPACE ON SHEET LP-2 TO MEET THE REQUIREMENTS FOR | | | THE CWD-CD. IT MUST MEET THE DEFINITION FOUND IN | | | SECTION 94-109, AND HAVE A LANDSCAPE PLAN PROVIDED. | | | THE TERRACE PROVIDED WITHOUT MEETING THE VEGETATIVE | | | COVER REQUIREMENT REQUIRES DAC BOARD APPROVAL FOR A | | | VARIANCE. STAFF MAY SUPPORT THE VARIANCE DUE TO THE | | | HISTORIC VALUE OF THE BUILDING. | | | | | | 2. SATISFIED. THE CWD-10 SITE IS LESS THAN 50,000 SQ | | | FT, SO NO PUBLIC OPEN SPACE IS REQUIRED. PLEASE CORRECT | | | THE OPEN SPACE CHART TO REFLECT THIS. | | | | | | 3. SATISFIED. PLEASE CLARIFY THE AREA COUNTED AS | | | PRIVATE OPEN SPACE TO MEET THE 25% REQUIREMENT ON THE | | | CWD-10 SITE, AND SHOW THAT IT MEETS THE REQUIRED | | | VEGETATED AND CANOPY AREAS. | | | | | | THE ROOFTOP GARDEN CATEGORY OF PRIVATE OPEN SPACE | | | CONTAINS AMENITIES BY DEFINITION, AND REQUIRES 30% | | | VEGETATED AREA AND 20% TREE CANOPY. THE AREA IS | | | COMBINED FOR BOTH BUILDINGS AND SHOULD MEET THESE | | | REQUIREMENTS FOR THE TOTAL ROOFTOP GARDEN SQUARE | | | FOOTAGE. | | | | | | 4. SATISFIED. PLEASE USE THE WATER NEEDS CATEGORY FOR | | | EACH SPECIES ON THE PLANT LIST FROM THE SFWMD WATERWISE | | | GUIDE TO SHOW COMPLIANCE WITH THE FLORIDA FRIENDLY | | | LANDSCAPE CHART SECTION 94-446 (G). | | | | | | 5. NOT SATISFIED. PLEASE PROVIDE A TREE DISPOSITION | | | PLAN INDICATING WHETHER THE EXISTING TREES AND PALMS ON | | | SITE WILL BE RELOCATED OR REMOVED. | | | | | | THERE ARE EIGHT EXISTING OAK TREES IN THE PARKING AREA | | | OF 531 DATURA, PLEASE PROVIDE A DISPOSITION PLAN. | | | THE 8 OAK TREES ARE CLEARLY MARKED ON THE SURVEY | | | SUPPLIED BY THE APPLICANT. THEY ARE ALSO CLEARLY | | | IDENTIFIABLE ON SITE. | | | | | | 6. SATISFIED. STREET TREES MUST BE 14 FEET MINIMUM. | | | PLEASE REVISE AND CONSIDER A DIFFERENT SPECIES IF THE | | | OVERHEAD LINES ARE OF CONCERN ON DATURA. | | | THE HIGH VOLTAGE TRANSMISSION LINES REQUIRE A 30 FOOT | | | SETBACK FOR OAK TREES BY FPL STANDARDS. PLEASE | | | RECOMMEND A DIFFERENT STREET TREE SPECIES THAT MEETS | | | FPL STANDARDS ALONG DATURA. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
09-20-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
09-20-2016 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
09-20-2016 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2016-09-20 09:55:22 | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: CLEMATIS PLACE Z16020009 | | | SEPTEMBER 20, 2016 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. NOT SATISFIED. PLEASE REVISE THE OPEN SPACE DIAGRAM | | | AND CALCULATIONS TO SHOW THE REQUIRED 20% TERRACE | | | PRIVATE OPEN SPACE ON SHEET LP-2 TO MEET THE | | | REQUIREMENTS FOR THE CWD-CD. IT MUST MEET THE | | | DEFINITION FOUND IN SECTION 94-109, AND HAVE A | | | LANDSCAPE PLAN PROVIDED. | | | THE TERRACE PROVIDED WITHOUT MEETING THE VEGETATIVE | | | COVER REQUIREMENT REQUIRES DAC BOARD APPROVAL FOR A | | | VARIANCE. STAFF MAY SUPPORT THE VARIANCE DUE TO THE | | | HISTORIC VALUE OF THE BUILDING. | | | | | | 2. SATISFIED. THE CWD-10 SITE IS LESS THAN 50,000 SQ | | | FT, SO NO PUBLIC OPEN SPACE IS REQUIRED. PLEASE CORRECT | | | THE OPEN SPACE CHART TO REFLECT THIS. | | | | | | 3. NOT SATISFIED. PLEASE CLARIFY THE AREA COUNTED AS | | | PRIVATE OPEN SPACE TO MEET THE 25% REQUIREMENT ON THE | | | CWD-10 SITE, AND SHOW THAT IT MEETS THE REQUIRED | | | VEGETATED AND CANOPY AREAS. | | | | | | THE ROOFTOP GARDEN CATEGORY OF PRIVATE OPEN SPACE | | | CONTAINS AMENITIES BY DEFINITION, AND REQUIRES 30% | | | VEGETATED AREA AND 20% TREE CANOPY. THE AREA IS | | | COMBINED FOR BOTH BUILDINGS AND SHOULD MEET THESE | | | REQUIREMENTS FOR THE TOTAL ROOFTOP GARDEN SQUARE | | | FOOTAGE. | | | | | | 4. SATISFIED. PLEASE USE THE WATER NEEDS CATEGORY FOR | | | EACH SPECIES ON THE PLANT LIST FROM THE SFWMD WATERWISE | | | GUIDE TO SHOW COMPLIANCE WITH THE FLORIDA FRIENDLY | | | LANDSCAPE CHART SECTION 94-446 (G). | | | | | | 5. NOT SATISFIED. PLEASE PROVIDE A TREE DISPOSITION | | | PLAN INDICATING WHETHER THE EXISTING TREES AND PALMS ON | | | SITE WILL BE RELOCATED OR REMOVED. | | | | | | THERE ARE EIGHT EXISTING OAK TREES IN THE PARKING AREA | | | OF 531 DATURA, PLEASE PROVIDE A DISPOSITION PLAN. | | | | | | 6. PARTIALLY SATISFIED. STREET TREES MUST BE 14 FEET | | | MINIMUM. PLEASE REVISE AND CONSIDER A DIFFERENT SPECIES | | | IF THE OVERHEAD LINES ARE OF CONCERN ON DATURA. | | | THE HIGH VOLTAGE TRANSMISSION LINES REQUIRE A 30 FOOT | | | SETBACK FOR OAK TREES BY FPL STANDARDS. PLEASE | | | RECOMMEND A DIFFERENT STREET TREE SPECIES THAT MEETS | | | FPL STANDARDS ALONG DATURA. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
03-07-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
03-07-2016 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
03-07-2016 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2016-03-07 17:09:13 | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: CLEMATIS PLACE Z16020009 | | | MARCH 7, 2016 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PLEASE REVISE THE OPEN SPACE DIAGRAM AND | | | CALCULATIONS TO SHOW THE REQUIRED 20% TERRACE PRIVATE | | | OPEN SPACE ON SHEET LP-2 TO MEET THE REQUIREMENTS FOR | | | THE CWD-CD. IT MUST MEET THE DEFINITION FOUND IN | | | SECTION 94-109, AND HAVE A LANDSCAPE PLAN PROVIDED. | | | | | | 2. THE CWD-10 SITE IS LESS THAN 50,000 SQ FT, SO NO | | | PUBLIC OPEN SPACE IS REQUIRED. PLEASE CORRECT THE OPEN | | | SPACE CHART TO REFLECT THIS. | | | | | | 3. PLEASE CLARIFY THE AREA COUNTED AS PRIVATE OPEN | | | SPACE TO MEET THE 25% REQUIREMENT ON THE CWD-10 SITE, | | | AND SHOW THAT IT MEETS THE REQUIRED VEGETATED AND | | | CANOPY AREAS. | | | | | | 4. PLEASE USE THE WATER NEEDS CATEGORY FOR EACH SPECIES | | | ON THE PLANT LIST FROM THE SFWMD WATERWISE GUIDE TO | | | SHOW COMPLIANCE WITH THE FLORIDA FRIENDLY LANDSCAPE | | | CHART SECTION 94-446 (G). | | | | | | 5. PLEASE PROVIDE A TREE DISPOSITION PLAN INDICATING | | | WHETHER THE EXISTING TREES AND PALMS ON SITE WILL BE | | | RELOCATED OR REMOVED. | | | | | | 6. STREET TREES MUST BE 14 FEET MINIMUM. PLEASE REVISE | | | AND CONSIDER A DIFFERENT SPECIES IF THE OVERHEAD LINES | | | ARE OF CONCERN ON DATURA. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES AND RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING AND IRRIGATION. THIS WILL BE THROUGH A | | | SEPARATE MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
03-08-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-08-2016 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-08-2016 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2016-03-08 15:53:06 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
03-08-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-08-2016 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-08-2016 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2016-03-08 15:52:47 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
03-08-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-08-2016 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-08-2016 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2016-03-08 15:52:32 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
03-08-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-08-2016 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-08-2016 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2016-03-08 15:52:16 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
01-19-2017 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
01-19-2017 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
01-19-2017 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2017-02-01 12:01:19 | ADDITONAL COMMENTS FOR DAC SPECIAL REVIEW: | | | 1. STAFF RECOMMENDS THE BUILDING ENTRANCE TO THE | | | RESIDENTIAL USE SHALL HAVE SOME ARCHITECTURAL TREATMENT | | | THAT DIFFERENCIATES THE CORNER FROM THE RETAIL PORTION | | | OF THE BUILDING. | | | 2. STAFF IS RECOMMENDING THE ALLEY OPENING TO BE | | | REDUCED FROM THE PROPOSED 26'-6" TO 22'. THE DOWNTOWN | | | ALLEYS ARE ENVISIONED AS SHARED ROADS AND DO NOT NEED A | | | SEPARATE SIDEWALK. | | | 3. PLEASE PROVIDE WINDOWS ON THE TWO RETAIL WALLS | | | FACING THE ALLEY. | | | 4. PLEASE LOOK AT THE OPTION TO TAKE THE GLASS BREAK | | | PROPOSED ALL THE WAY DOWN AND RECESS IT THE NECESSARY | | | AMOUNT TO COMPLY WITH THE PLANAR BREAK REQUIREMENTS ON | | | THE DATURA ELEVATION. PLEASE JUSTIFY THE VARIANCE | | | REQUEST IF NEEDED. | | | 5. PLEASE PROPOSE SOME OPTIONS TO MAKE THE ALLEY | | | CIRCULATION MORE ATTRACTIVE FOR PEDESTRIANS AND | | | MINIMIZE THE NEGATIVE IMPACT OF THE GARAGE OVER THE | | | ALLEY. SUGGEST HOW THE PAVERS ON ROSEMARY ARE GOING TO | | | TRANSITION INTO THE ALLEY MATERIAL. STAFF SUFFEST THE | | | ALLEY MATERIAL SHALL BE ENHANCED BEYOND SIMPLE ASPHALT | | | COAT. | | | 6. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | | WITH BLANK WALL REGULATION ON THE EAST FACADE. | | | TREATMENT OF THE GARAGE WALL FACING EAST. | | | 7. STAFF RECOMMENDS THE STAGGERED SETBACK ON THE UPPER | | | LEVELS OF THE CLEMATIS ELEVATION (ABOVE PODIUM) TO BE | | | LARGER, MINIMIZING THE IMPACT OF THE 12 STORY BUILDING | | | ON THE HISTORIC DISTRICT. | | | 8. STAFF RECOMMENDS THE BRICK FACADE TO PROJECT BELOW | | | THE MINIMUM CELARANCE REQUIRED FOR THE ALLEY TO | | | ACCOMPLISH A BETTER PEDESTRIAN SCALE FOR THE 1ST FLOOR | | | OF THE BUILDING. EXACT DIMENSION TO BE DETERMINED WITH | | | ENGINEERING TOENSURE CLEARANCE FOR TRUCKS ENTERING THE | | | ALLEY IS PROVIDED. | | | 9. AWNINGS ON DATURA SHALL REFLECT THE SMALLER SIZE | | | ALREDY INCLUDED IN THE ROSEMARY ELEVATIONS. | | | 10. ARE THE ROUND COLUMNS ON THE FIRST FLOOR FREE | | | STANDING SEPARATED FROM THE GLASS STOREFRONT? | | | RENDERINGS SEEM TO INDICATE THAT, BUT FLOOR PLANS ARE | | | NOT. | | | | | | | | | 1. TDR APPROVAL STILL NEEDED. HPB APPROVAL DONE-SITE IS | | | WITHIN A HISTORIC DISTRICT AND AS SUCH APPROVAL FROM | | | THE HISTORIC PRESERVATION BOARD IS REQUIRED. IN | | | ADDITION, AND DUE TO PROPOSED UTILIZATION OF THE TDR | | | INCENTIVE PROGRAM, THE SITE REQUIRES APPROVAL FROM THE | | | DOWNTOWN ACTION COMMITTEE (SPECIAL REVIEW STANDARDS). | | | 2. DONE- SETBACK ON ROSEMARY AVENUE SHALL BE MEASURED | | | FROM THE BACK OF THE PLANTER CURB. | | | 3. DONE- PAVERS ON ROSEMARY AVENUE SHALL MATCH EXISTING | | | PAVERS IN COLOR, PATTERN, TEXTURE ETC. | | | 4. DONE- FIRST FLOOR ALONG ROSEMARY AVENUE COMPLIES | | | WITH THE MINIMUM 228.8 RETAIL REQUIREMENT. HOWEVER, | | | STAFF RECOMMENDS THE RELOCATION OF THE FITNESS CENTER | | | AND THE USE OF THE PROMINENT CORNER SPACE FOR THE LOBBY | | | ENTRANCE OR COMMERCIAL SPACE (OFFICES ALLOWED- RETAIL | | | ALLOWED BUT NOT REQUIRED). | | | 5. NOT SATISFIED. PLEASE CONFIRM FINAL DECISION ON | | | ALLOWING THE DUMPSTER TO BE ROLLED OUT TO THE ALLEY FOR | | | PICK UP- PLEASE EXPLAIN THE GARBAGE COLLECTION | | | OPERATION. WHAT TYPE OF CONTAINER/PICK UP IS PROPOSED? | | | - 1ST REVIEW: PLEASE INDICATE HOW IS THE GARBAGE | | | PICK-UP OPERATION (CIRCULATION, STAGING, PRIVATE OR | | | PUBLIC). | | | 6. DONE-PARTIALLY SATISFIED - PLEASE INDICATE THE RAMP | | | SLOPE IN PERCENTAGE AND IN ALL RAMPS PROPOSED WITHIN | | | THE GARAGE - 1ST REVIEW: PLEASE INDICATE THE PARKING | | | RAMP PROPOSED SLOPE (SEC 94-111 (Q)(2) - NON-PARKING | | | RAMP SLOPE HIGHER THAN 14% REQUIRES A BREAK-OVER | | | TRANSITION). | | | 7. DONE- DEAD-END PARKING REQUIRES A TURN-AROUND SPACE. | | | 8. DONE -NOT SATISFIED - PLEASE PROVIDE ALL THE FLOOR | | | LEVELS ABOVE THE 7TH STORY AS IT SEEMS FOR THE | | | INFORMATION PROVIDED IN THE FACADES THE UPPER LEVEL ARE | | | ALL DIFFERENT AND STEP BACK FROM CLEMATIS AS THEY GO | | | HIGHER. - 1ST REVIEW: FACADES AND RENDERING FACING | | | NORTH ARE NOT CONSISTENT WITH FLOOR PLANS (CANTILEVER | | | CONDITION AND STEP BACK CONDITIONS) | | | 9. DONE- DATURA ELEVATION DOES NOT SHOW THE GARAGE | | | ENTRANCE. | | | 10. DONE-PARTIALLY SATISFIED- SHEET A2.01 STILL SHOWS | | | SETBACK ON CLEMATIS AT 52'.- 1ST REVIEW: ALONG CLEMATIS | | | STREET A 56' CONDITIONAL SETBACK IS REQUIRED ABOVE THE | | | 2ND FLOOR. PROPOSAL SEEMS TO BE AT 52' ONLY. PLEASE | | | INCLUDE DIMENSION FROM THE BACK OF THE EXISTING CURB. | | | 11. DONE- PLEASE PROVIDE AUTO TURN FOR THE LOADING | | | AREAS. | | | 12. - DONE- SITE PLAN SHOWS THE ALLEY OPENING (WALL TO | | | WALL) TO BE AROUND 26' WHILE ELEVATION SHOWS THE ALLEY | | | OPENING AT 34' IN WIDTH. | | | 13. NOT SATISFIED- PLEASE LOOK AT DEFINITION OF PLANAR | | | BREAK, TABLE IV-4 AND FIGURE IV-21 TO CONFIRM | | | COMPLIANCE. FOR COMPLIANCE WITH TRANSPARENCY PLEASE | | | SHOW DIAGRAMS ON ELEVATIONS WITH TRANSPARENCY AREAS.- | | | 1ST REVIEW: PLEASE PROVIDE INFORMATION TO CONFIRM | | | COMPLIANCE WITH THE PLANAR BREAK REGULATIONS, AND | | | TRANSPARENCY. | | | 14. DONE-NOT SATISFIED- DUE TO THE HISTORIC NATURE OF | | | THE EXISTING BUILDINGS ON CLEMATIS STREET THE TERRACE | | | WILL NOT BE PERMITTED ON THE ROOF OF HISTORIC | | | BUILDINGS. THE REQUIRED AREA SHALL BE RELOCATED TO THE | | | ROOF TOP GARDEN. - 1ST REVIEW:THE SETBACK REQUIRED | | | ABOVE THE 2ND STORY, AND PROVIDED IN THIS PROJECT ABOVE | | | THE 1ST STORY SHALL BE DESIGNED AS A TERRACE (20% OF | | | THE CWD-CD SITE). | | | 15. DONE- PLEASE DOCUMENT ALL THE EXISTING CONDITIONS | | | FOR THE ADJACENT PROPERTY ON THE EAST SIDE OF THE | | | SUBJECT PARCEL, AND IDENTIFY ANY POSSIBLE CONFLICTS AND | | | IMPACTS. | | | 16. DONE - AN AERIAL AND UDNERGROUND EASEMENT WILL BE | | | PROVIDED. PROJECT LEGAL TEAM TO WORK WITH THE CITY ON | | | DRAFT AGREEMENT AND APPROVAL OF EASEMENT.- 1ST REVIEW: | | | PROPOSAL TO EXPAND THE BUILDING OVER THE ALLEY SHALL BE | | | DISCUSSED FURTHER. INITIAL OPTIONS ARE 1. ABANDONING | | | THE ALLEY BUT REQUIRE AN ACCESS AND UTILITY EASEMENT; | | | OR 2. AIR RIGHT EASEMENT AND UNDERGROUND EASEMENT. | | | 17. DONE- PLEASE INDICATE THE CONDITIONS OF THE | | | SIDEWALK ON DATURA STREET EAST OF THE PROJECT AND HOW | | | IT WILL TRANSITION TO THE NEW HARDSCAPE. | | | 18. DONE- PLEASE INDICATE INFORMATION ON SITE PLAN | | | REFLECTING EXISTING CONDITIONS- 1ST REVIEW:PLEASE | | | INDICATE IF ANY ON-STREET PARKING IS GOING TO BE | | | REMOVED. | | | 19. DONE - PLEASE SPECIFY THE PLANTING DETAIL FOR THE | | | PROPOSED OAKS ALONG DATURA STREET CONSIDERING THE | | | UNDERGROUND PARKING IS BEING PROPOSED UNDER THE | | | EXISTING SIDEWALK. ARE THE PROPOSED TREES VIABLE? | | | | | | ADDITIONAL COMMENTS ON SUBMITTAL PACKAGE: | | | 19. NOT SATISFIED - SURVEY SHALL INCLUDE THE SQURE | | | FOOTAGE OF NORTH AND SOUTH PARCELS SEPARATELY. IT SHALL | | | ALSO INCLUDE SIDEWALK DIMENSIONS AND DISTANCE FROM BACK | | | OF CURB TO PROPERTY LINE. - 1ST REVIEW: DATA ON SURVEY | | | SHOWS TOTAL PARCEL AREA AS 43,584 OR 1.23 ACRE. PLEASE | | | CORRECT NUMBER AND PROVIDE SQUARE FOOTAGE FOR THE GROUP | | | OF PROPERTIES DESIGNATED CWD-CD AND CWD-10 SEPARATELY. | | | SURVEY SHALL INCLUDE MEASUREMENTS OF THE EXISTING | | | SIDEWALKS, AND ROW INCLUDING SIDEWALK ACROSS THE | | | STREET. | | | 20. DONE- PLEASE ADJUST THE LOT SIZE AREAS TO BE | | | CONSISTENT IN ALL THE DRAWINGS BASED ON THE SURVEY | | | INFORMATION. | | | 21. DONE - PARTIALLY SATISFIED- PLEASE INDICATE THE TWO | | | PROPERTY LINES ON DATURA IN SHEET A2.01.- 1ST REVIEW: | | | PLEASE INCLUDE PROPERTY LINES AND SETBACK LINES IN ALL | | | FLOOR PLANS AND ELEVATIONS. | | | 22. DONE- SHEET A1.02 DOES NOT SEEM TO BE ACCURATE | | | (ACCESS RAMP NOT SHOWN). | | | 23. DONE- PARTIALLY SATISFIED- PLEASE PROVIDE | | | RENDERINGS WITHIN THE REAL CONTEXT, HOW IS THE PROJECT | | | INSERTED ON THE SITE AND HOW IT WILL IMPACT THE | | | PERCEPTION FROM THE STREET. THE SUBMITTED RENDERINGS | | | ARE GOOD TO PROVIDE A VISUAL OF THE ENTIRE BUILDING, | | | BUT ARE NOT ACCURATELY REFLECTING THE SCALE OF THE | | | BUILDING IN RELATION TO THE STREET AND THE ADJACENT | | | BUILDING (ROSEMAY SECTION). TAHT TYPE OF RENDERINGS ARE | | | IMPORTANT FOR THE SPECIAL REVIEW APPROVAL- 1ST REVIEW: | | | THE INTENTIONRENDERING IN SHEET R0-02 IS NOT ACCURATE | | | IN THE PLACEMENT OF THE SURROUNDING BUILDINGS. ALL | | | RENDERINGS SHALL ACCURATELY REFLECT THE EXISTING | | | CONDITIONS OF THE SURROUNDING AREA. | | | 24. DONE- NOT SATISFIED- SUBMITTED ELEVATIONS ARE BLACK | | | AND WHITE. - 1ST REVIEW: PLEASE INCLUDE NORTH AND EAST | | | COLORED ELEVATIONS. PLEASE INDICATE SCALE ON ALL | | | ELEVATIONS. | | | 25. NOT SATISFIED.- 1ST REVIEW: FOR THE DAC SPECIAL | | | REVIEW FLOOR PLANS AND ELEVATIONS SHALL BE MORE | | | DETAILED INDICATING LOCATION OF WINDOWS, BUILDING | | | ENTRANCES AND BALCONIES. FACADE SHALL INCLUDE A CALL | | | OUT FOR PROPOSED MATERIALS AND IMAGES OF THE PROPOSED | | | MATERIALS. A MATERIAL BOARD WILL BE REQUIRED FOR THE | | | HEARING. | | | 26. NOT SATISFIED - 1ST REVIEW: FOR DAC, COMPLIANCE | | | WITH SPECIAL REVIEW STANDARDS SHALL BE DEMONSTRATED. | | | 27. DONE- PLEASE PROVIDE ELECTRONIC DRAWINGS (DXF OR | | | CADD) TO ALLOW THE MEASUREMENT OF THE FAR AREA | | | INDICATED IN SHEET A0.06. | | | 28. DONE - PLEASE ENSURE ALL THE DRAWINGS ARE PRINTED | | | AT SCALE (SHEET A1.01 IS NOT AT SCALE). STAFF WAS NOT | | | ABLE TO VERIFY ANY DIMENSION ON SUBMITTED DRAWINGS. | | | 29. DONE- PLEASE CORRECT FAR CALCULATION IN SHEET | | | A1.01AND A0.01. ADDITIONAL FAR PERMITTED ON CWD-10/12 | | | IS ONLY 14,780SF. ADJUST TOTAL ALLOWED. | | | | | | SPECIAL REVIEW COMMENTS: | | | 1. PARTIALLY SATISFIED- THE TREATMENT AND SCALE OF THE | | | 1ST FLOOR ALONG ROSEMAY AVE DOES NOT RELATE TO THE | | | SCALE OF ROSEMARY AVE, OR THE ADJACENT BUILDINGS. THE | | | PROPOSED LARGE AWNINGS ARE NOT APPROPRIATE FOR THE | | | HISTORIC DISTRICT. | | | 2. PARTIALLY SATISFIED- THE SCALE OF THE 1ST FLOOR | | | SHALL BE LOWERED. | | | | | | HPB APPROVAL CONDITIONS SHALL BE INCORPORATED - | | | COMMENTS FROM CITY'S HISTORIC PRESERVATION PLANNER: | | | AFTER PRELIMINARILY REVIEWING THE PROPOSED PROJECT I | | | OFFER THE FOLLOWING COMMENTS: | | | | | | 1. ADDITION/NEW CONSTRUCTION IN HISTORIC DISTRICT | | | REQUIRES APPROVAL BY THE HISTORIC PRESERVATION BOARD. | | | 2. PLANS ARE NOT DETAILED ENOUGH TO UNDERSTAND | | | REHABILITATION EFFORTS ON EXISTING HISTORIC STRUCTURES, | | | PLEASE PROVIDE CLARIFICATION. | | | 3. PROPOSED ADDITION DOES NOT COMPLY WITH SECTION | | | 94-49, SPECIFICALLY; | | | SETTING, ORIENTATION AND SETBACKS IS NOT COMPATIBLE | | | WITH DISTRICT UTILIZING INVERSE STEPPING OF BUILDING AS | | | PROPOSED | | | PROPORTION OF OPENINGS ARE NOT VISUALLY COMPATIBLE WITH | | | SURROUNDING BUILDINGS | | | RHYTHM OF SOLIDS TO VOIDS IS NOT VISUALLY COMPATIBLE | | | AND | | | THE SIZE, SCALE, MASS AND VOLUME OVERWHELMS THE | | | EXISTING STRUCTURES. | | | 2. DETAILED PLANS OF SHORING/SUPPORT SHALL BE SUBMITTED | | | PRIOR TO PERMITTING TO ENSURE NO DAMAGE OCCURS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
01-06-2017 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
10-14-2016 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
10-14-2016 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2016-10-14 16:21:21 | 1. SITE IS WITHIN A HISTORIC DISTRICT AND AS SUCH | | | APPROVAL FROM THE HISTORIC PRESERVATION BOARD IS | | | REQUIRED. IN ADDITION, AND DUE TO PROPOSED UTILIZATION | | | OF THE TDR INCENTIVE PROGRAM, THE SITE REQUIRES | | | APPROVAL FROM THE DOWNTOWN ACTION COMMITTEE (SPECIAL | | | REVIEW STANDARDS). | | | 2. DONE- SETBACK ON ROSEMARY AVENUE SHALL BE MEASURED | | | FROM THE BACK OF THE PLANTER CURB. | | | 3. DONE- PAVERS ON ROSEMARY AVENUE SHALL MATCH EXISTING | | | PAVERS IN COLOR, PATTERN, TEXTURE ETC. | | | 4. DONE- FIRST FLOOR ALONG ROSEMARY AVENUE COMPLIES | | | WITH THE MINIMUM 228.8 RETAIL REQUIREMENT. HOWEVER, | | | STAFF RECOMMENDS THE RELOCATION OF THE FITNESS CENTER | | | AND THE USE OF THE PROMINENT CORNER SPACE FOR THE LOBBY | | | ENTRANCE OR COMMERCIAL SPACE (OFFICES ALLOWED- RETAIL | | | ALLOWED BUT NOT REQUIRED). | | | 5. NOT SATISFIED. PLEASE EXPLAIN THE GARBAGE COLLECTION | | | OPERATION. WHAT TYPE OF CONTAINER/PICK UP IS PROPOSED? | | | - 1ST REVIEW: PLEASE INDICATE HOW IS THE GARBAGE | | | PICK-UP OPERATION (CIRCULATION, STAGING, PRIVATE OR | | | PUBLIC). | | | 6. PARTIALLY SATISFIED - PLEASE INDICATE THE RAMP SLOPE | | | IN PERCENTAGE AND IN ALL RAMPS PROPOSED WITHIN THE | | | GARAGE - 1ST REVIEW: PLEASE INDICATE THE PARKING RAMP | | | PROPOSED SLOPE (SEC 94-111 (Q)(2) - NON-PARKING RAMP | | | SLOPE HIGHER THAN 14% REQUIRES A BREAK-OVER | | | TRANSITION). | | | 7. DONE- DEAD-END PARKING REQUIRES A TURN-AROUND SPACE. | | | 8. NOT SATISFIED - PLEASE PROVIDE ALL THE FLOOR LEVELS | | | ABOVE THE 7TH STORY AS IT SEEMS FOR THE INFORMATION | | | PROVIDED IN THE FACADES THE UPPER LEVEL ARE ALL | | | DIFFERENT AND STEP BACK FROM CLEMATIS AS THEY GO | | | HIGHER. - 1ST REVIEW: FACADES AND RENDERING FACING | | | NORTH ARE NOT CONSISTENT WITH FLOOR PLANS (CANTILEVER | | | CONDITION AND STEP BACK CONDITIONS) | | | 9. DONE- DATURA ELEVATION DOES NOT SHOW THE GARAGE | | | ENTRANCE. | | | 10. PARTIALLY SATISFIED- SHEET A2.01 STILL SHOWS | | | SETBACK ON CLEMATIS AT 52'.- 1ST REVIEW: ALONG CLEMATIS | | | STREET A 56' CONDITIONAL SETBACK IS REQUIRED ABOVE THE | | | 2ND FLOOR. PROPOSAL SEEMS TO BE AT 52' ONLY. PLEASE | | | INCLUDE DIMENSION FROM THE BACK OF THE EXISTING CURB. | | | 11. DONE- PLEASE PROVIDE AUTO TURN FOR THE LOADING | | | AREAS. | | | 12. - DONE- SITE PLAN SHOWS THE ALLEY OPENING (WALL TO | | | WALL) TO BE AROUND 26' WHILE ELEVATION SHOWS THE ALLEY | | | OPENING AT 34' IN WIDTH. | | | 13. NOT SATISFIED- PLEASE LOOK AT DEFINITION OF PLANAR | | | BREAK, TABLE IV-4 AND FIGURE IV-21 TO CONFIRM | | | COMPLIANCE. FOR COMPLIANCE WITH TRANSPARENCY PLEASE | | | SHOW DIAGRAMS ON ELEVATIONS WITH TRANSPARENCY AREAS.- | | | 1ST REVIEW: PLEASE PROVIDE INFORMATION TO CONFIRM | | | COMPLIANCE WITH THE PLANAR BREAK REGULATIONS, AND | | | TRANSPARENCY. | | | 14. NOT SATISFIED- DUE TO THE HISTORIC NATURE OF THE | | | EXISTING BUILDINGS ON CLEMATIS STREET THE TERRACE WILL | | | NOT BE PERMITTED ON THE ROOF OF HISTORIC BUILDINGS. THE | | | REQUIRED AREA SHALL BE RELOCATED TO THE ROOF TOP | | | GARDEN. - 1ST REVIEW:THE SETBACK REQUIRED ABOVE THE 2ND | | | STORY, AND PROVIDED IN THIS PROJECT ABOVE THE 1ST STORY | | | SHALL BE DESIGNED AS A TERRACE (20% OF THE CWD-CD | | | SITE). | | | 15. DONE- PLEASE DOCUMENT ALL THE EXISTING CONDITIONS | | | FOR THE ADJACENT PROPERTY ON THE EAST SIDE OF THE | | | SUBJECT PARCEL, AND IDENTIFY ANY POSSIBLE CONFLICTS AND | | | IMPACTS. | | | 16. DONE - AN AERIAL AND UDNERGROUND EASEMENT WILL BE | | | PROVIDED. PROJECT LEGAL TEAM TO WORK WITH THE CITY ON | | | DRAFT AGREEMENT AND APPROVAL OF EASEMENT.- 1ST REVIEW: | | | PROPOSAL TO EXPAND THE BUILDING OVER THE ALLEY SHALL BE | | | DISCUSSED FURTHER. INITIAL OPTIONS ARE 1. ABANDONING | | | THE ALLEY BUT REQUIRE AN ACCESS AND UTILITY EASEMENT; | | | OR 2. AIR RIGHT EASEMENT AND UNDERGROUND EASEMENT. | | | 17. DONE- PLEASE INDICATE THE CONDITIONS OF THE | | | SIDEWALK ON DATURA STREET EAST OF THE PROJECT AND HOW | | | IT WILL TRANSITION TO THE NEW HARDSCAPE. | | | 18. DONE- PLEASE INDICATE INFORMATION ON SITE PLAN | | | REFLECTING EXISTING CONDITIONS- 1ST REVIEW:PLEASE | | | INDICATE IF ANY ON-STREET PARKING IS GOING TO BE | | | REMOVED. | | | 19. PLEASE SPECIFY THE PLANTING DETAIL FOR THE PROPOSED | | | OAKS ALONG DATURA STREET CONSIDERING THE UNDERGROUND | | | PARKING IS BEING PROPOSED UNDER THE EXISTING SIDEWALK. | | | ARE THE PROPOSED TREES VIABLE? | | | | | | ADDITIONAL COMMENTS ON SUBMITTAL PACKAGE: | | | 19. NOT SATISFIED - SURVEY SHALL INCLUDE THE SQURE | | | FOOTAGE OF NORTH AND SOUTH PARCELS SEPARATELY. IT SHALL | | | ALSO INCLUDE SIDEWALK DIMENSIONS AND DISTANCE FROM BACK | | | OF CURB TO PROPERTY LINE. - 1ST REVIEW: DATA ON SURVEY | | | SHOWS TOTAL PARCEL AREA AS 43,584 OR 1.23 ACRE. PLEASE | | | CORRECT NUMBER AND PROVIDE SQUARE FOOTAGE FOR THE GROUP | | | OF PROPERTIES DESIGNATED CWD-CD AND CWD-10 SEPARATELY. | | | SURVEY SHALL INCLUDE MEASUREMENTS OF THE EXISTING | | | SIDEWALKS, AND ROW INCLUDING SIDEWALK ACROSS THE | | | STREET. | | | 20. DONE- PLEASE ADJUST THE LOT SIZE AREAS TO BE | | | CONSISTENT IN ALL THE DRAWINGS BASED ON THE SURVEY | | | INFORMATION. | | | 21. PARTIALLY SATISFIED- PLEASE INDICATE THE TWO | | | PROPERTY LINES ON DATURA IN SHEET A2.01.- 1ST REVIEW: | | | PLEASE INCLUDE PROPERTY LINES AND SETBACK LINES IN ALL | | | FLOOR PLANS AND ELEVATIONS. | | | 22. DONE- SHEET A1.02 DOES NOT SEEM TO BE ACCURATE | | | (ACCESS RAMP NOT SHOWN). | | | 23. PARTIALLY SATISFIED- PLEASE PROVIDE RENDERINGS | | | WITHIN THE REAL CONTEXT, HOW IS THE PROJECT INSERTED ON | | | THE SITE AND HOW IT WILL IMPACT THE PERCEPTION FROM THE | | | STREET. THE SUBMITTED RENDERINGS ARE GOOD TO PROVIDE A | | | VISUAL OF THE ENTIRE BUILDING, BUT ARE NOT ACCURATELY | | | REFLECTING THE SCALE OF THE BUILDING IN RELATION TO THE | | | STREET AND THE ADJACENT BUILDING (ROSEMAY SECTION). | | | TAHT TYPE OF RENDERINGS ARE IMPORTANT FOR THE SPECIAL | | | REVIEW APPROVAL- 1ST REVIEW: THE INTENTIONRENDERING IN | | | SHEET R0-02 IS NOT ACCURATE IN THE PLACEMENT OF THE | | | SURROUNDING BUILDINGS. ALL RENDERINGS SHALL ACCURATELY | | | REFLECT THE EXISTING CONDITIONS OF THE SURROUNDING | | | AREA. | | | 24. NOT SATISFIED- SUBMITTED ELEVATIONS ARE BLACK AND | | | WHITE. - 1ST REVIEW: PLEASE INCLUDE NORTH AND EAST | | | COLORED ELEVATIONS. PLEASE INDICATE SCALE ON ALL | | | ELEVATIONS. | | | 25. NOT SATISFIED.- 1ST REVIEW: FOR THE DAC SPECIAL | | | REVIEW FLOOR PLANS AND ELEVATIONS SHALL BE MORE | | | DETAILED INDICATING LOCATION OF WINDOWS, BUILDING | | | ENTRANCES AND BALCONIES. FACADE SHALL INCLUDE A CALL | | | OUT FOR PROPOSED MATERIALS AND IMAGES OF THE PROPOSED | | | MATERIALS. A MATERIAL BOARD WILL BE REQUIRED FOR THE | | | HEARING. | | | 26. NOT SATISFIED - 1ST REVIEW: FOR DAC, COMPLIANCE | | | WITH SPECIAL REVIEW STANDARDS SHALL BE DEMONSTRATED. | | | 27. PLEASE PROVIDE ELECTRONIC DRAWINGS (DXF OR CADD) TO | | | ALLOW THE MEASUREMENT OF THE FAR AREA INDICATED IN | | | SHEET A0.06. | | | 28. PLEASE ENSURE ALL THE DRAWINGS ARE PRINTED AT SCALE | | | (SHEET A1.01 IS NOT AT SCALE). STAFF WAS NOT ABLE TO | | | VERIFY ANY DIMENSION ON SUBMITTED DRAWINGS. | | | 29. PLEASE CORRECT FAR CALCULATION IN SHEET A1.01AND | | | A0.01. ADDITIONAL FAR PERMITTED ON CWD-10/12 IS ONLY | | | 14,780SF. ADJUST TOTAL ALLOWED. | | | | | | SPECIAL REVIEW COMMENTS: | | | 1. THE TREATMENT AND SCALE OF THE 1ST FLOOR ALONG | | | ROSEMAY AVE DOES NOT RELATE TO THE SCALE OF ROSEMARY | | | AVE, OR THE ADJACENT BUILDINGS. THE PROPOSED LARGE | | | AWNINGS ARE NOT APPROPRIATE FOR THE HISTORIC DISTRICT. | | | 2. THE SCALE OF THE 1ST FLOOR SHALL BE LOWERED. | | | | | | COMMENTS FROM CITY'S HISTORIC PRESERVATION PLANNER: | | | AFTER PRELIMINARILY REVIEWING THE PROPOSED PROJECT I | | | OFFER THE FOLLOWING COMMENTS: | | | | | | 1. ADDITION/NEW CONSTRUCTION IN HISTORIC DISTRICT | | | REQUIRES APPROVAL BY THE HISTORIC PRESERVATION BOARD. | | | 2. PLANS ARE NOT DETAILED ENOUGH TO UNDERSTAND | | | REHABILITATION EFFORTS ON EXISTING HISTORIC STRUCTURES, | | | PLEASE PROVIDE CLARIFICATION. | | | 3. PROPOSED ADDITION DOES NOT COMPLY WITH SECTION | | | 94-49, SPECIFICALLY; | | | SETTING, ORIENTATION AND SETBACKS IS NOT COMPATIBLE | | | WITH DISTRICT UTILIZING INVERSE STEPPING OF BUILDING AS | | | PROPOSED | | | PROPORTION OF OPENINGS ARE NOT VISUALLY COMPATIBLE WITH | | | SURROUNDING BUILDINGS | | | RHYTHM OF SOLIDS TO VOIDS IS NOT VISUALLY COMPATIBLE | | | AND | | | THE SIZE, SCALE, MASS AND VOLUME OVERWHELMS THE | | | EXISTING STRUCTURES. | | | 2. DETAILED PLANS OF SHORING/SUPPORT SHALL BE SUBMITTED | | | PRIOR TO PERMITTING TO ENSURE NO DAMAGE OCCURS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
03-07-2016 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
03-07-2016 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
03-07-2016 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2016-03-07 15:30:53 | 1. SITE IS WIHTIN A HISTORIC DISTRICT AND AS SUCH | | | APPROVAL FROM THE HISTORIC PRESERVATION BOARD IS | | | REQUIRED. IN ADDITION, AND DUE TO PROPOSED UTILIZATION | | | OF THE TDR INCENTIVE PROGRAM, THE SITE REQUIRED | | | APPROVAL FROM THE DOWNTOWN ACTION COMMITTEE (SPECIAL | | | REVIEW STANDARDS). | | | 2. SETBACK ON ROSEMARY AVENUE SHALL BE MEASURED FROM | | | THE BACK OF THE PLANTER CURB. | | | 3. PAVERS ON ROSEMARY AVENUE SHALL MATCH EXISTING | | | PAVERS IN COLOR, PATTERN, TEXTURE ETC. | | | 4. FIRST FLOOR ALONG ROSEMARY AVENUE COMPLIES WITH THE | | | MINIMUM 228.8? RETAIL REQUIREMENT. HOWEVER, STAFF | | | RECOMMENDS THE RELOCATION OF THE FITNESS CENTER AND THE | | | USE OF THE PROMINENT CORNER SPACE FOR THE LOBBY | | | ENTRANCE OR COMMERCIAL SPACE (OFFICES ALLOWED- RETAIL | | | ALLOWED BUT NOT REQUIRED). | | | 5. PLEASE INDICATE HOW IS THE GARBAGE PICK-UP OPERATION | | | (CIRCULATION, STAGING, PRIVATE OR PUBLIC). | | | 6. PLEASE INDICATE THE PARKING RAMP PROPOSED SLOPE (SEC | | | 94-111 (Q)(2) ? NON-PARKING RAMP SLOPE HIGHER THAN 14% | | | REQUIRES A BREAK-OVER TRANSITION). | | | 7. DEAD-END PARKING REQUIRES A TURN-AROUND SPACE. | | | 8. FACADES AND RENDERING FACING NORTH ARE NOT | | | CONSISTENT WITH FLOOR PLANS (CANTILEVER CONDITION AND | | | STEP BACK CONDITIONS) | | | 9. DATURA ELEVATION DOES NOT SHOW THE GARAGE ENTRANCE. | | | 10. ALONG CLEMATIS STREET A 56? CONDITIONAL SETBACK IS | | | REQUIRED ABOVE THE 2ND FLOOR. PROPOSAL SEEMS TO BE AT | | | 52? ONLY. PLEASE INCLUDE DIMENSION FROM THE BACK OF THE | | | EXISTING CURB. | | | 11. PLEASE PROVIDE AUTO TURN FOR THE LOADING AREAS. | | | 12. SITE PLAN SHOWS THE ALLEY OPENING (WALL TO WALL) TO | | | BE AROUND 26? WHILE ELEVATION SHOWS THE ALLEY OPENING | | | AT 34? IN WIDTH. | | | 13. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE | | | WITH THE PLANAR BREAK REGULATIONS, AND TRANSPARENCY. | | | 14. THE SETBACK REQUIRED ABOVE THE 2ND STORY, AND | | | PROVIDED IN THIS PROJECT ABOVE THE 1ST STORY SHALL BE | | | DESIGNED AS A TERRACE (20% OF THE CWD-CD SITE). | | | 15. PLEASE DOCUMENT ALL THE EXISTING CONDITIONS FOR THE | | | ADJACENT PROPERTY ON THE EAST SIDE OF THE SUBJECT | | | PARCEL, AND IDENTIFY ANY POSSIBLE CONFLICTS AND | | | IMPACTS. | | | 16. PROPOSAL TO EXPAND THE BUILDING OVER THE ALLEY | | | SHALL BE DISCUSSED FURTHER. INITIAL OPTIONS ARE 1. | | | ABANDONING THE ALLEY BUT REQUIRE AN ACCESS AND UTILITY | | | EASEMENT; OR 2. AIR RIGHT EASEMENT AND UNDERGROUND | | | EASEMENT. | | | 17. PLEASE INDICATE THE CONDITIONS OF THE SIDEWALK ON | | | DATURA STREET EAST OF THE PROJECT AND HOW IT WILL | | | TRANSITION TO THE NEW HARDSCAPE. | | | 18. PLEASE INDICATE IF ANY ON-STREET PARKING IS GOING | | | TO BE REMOVED. | | | | | | ADDITIONAL COMMENTS ON SUBMITTAL PACKAGE: | | | 19. DATA ON SURVEY SHOWS TOTAL PARCEL AREA AS 43,584 OR | | | 1.23 ACRE. PLEASE CORRECT NUMBER AND PROVIDE SQUARE | | | FOOTAGE FOR THE GROUP OF PROPERTIES DESIGNATED CWD-CD | | | AND CWD-10 SEPARATELY. SURVEY SHALL INCLUDE | | | MEASUREMENTS OF THE EXISTING SIDEWALKS, AND ROW | | | INCLUDING SIDEWALK ACROSS THE STREET. | | | | | | 20. PLEASE ADJUST THE LOT SIZE AREAS TO BE CONSISTENT | | | IN ALL THE DRAWINGS BASED ON THE SURVEY INFORMATION. | | | 21. PLEASE INCLUDE PROPERTY LINES AND SETBACK LINES IN | | | ALL FLOOR PLANS AND ELEVATIONS. | | | 22. SHEET A1.02 DOES NOT SEEM TO BE ACCURATE (ACCESS | | | RAMP NOT SHOWN). | | | 23. RENDERING IN SHEET R0-02 IS NOT ACCURATE IN THE | | | PLACEMENT OF THE SURROUNDING BUILDINGS. ALL RENDERINGS | | | SHALL ACCURATELY REFLECT THE EXISTING CONDITIONS OF THE | | | SURROUNDING AREA. | | | 24. PLEASE INCLUDE NORTH AND EAST COLORED ELEVATIONS. | | | PLEASE INDICATE SCALE ON ALL ELEVATIONS. | | | 25. FOR THE DAC SPECIAL REVIEW FLOOR PLANS AND | | | ELEVATIONS SHALL BE MORE DETAILED INDICATING LOCATION | | | OF WINDOWS, BUILDING ENTRANCES AND BALCONIES. FACADE | | | SHALL INCLUDE A CALL OUT FOR PROPOSED MATERIALS AND | | | IMAGES OF THE PROPOSED MATERIALS. A MATERIAL BOARD WILL | | | BE REQUIRED FOR THE HEARING. | | | 26. FOR DAC, COMPLIANCE WITH SPECIAL REVIEW STANDARDS | | | SHALL BE DEMONSTRATED. | | | 27. PLEASE PROVIDE ELECTRONIC DRAWINGS (DXF OR CADD) TO | | | ALLOW THE MEASUREMENT OF THE FAR AREA INDICATED IN | | | SHEET A0.06. | | | | | | COMMENTS FROM CITY'S HISTORIC PRESERVATION PLANNER: | | | AFTER PRELIMINARILY REVIEWING THE PROPOSED PROJECT I | | | OFFER THE FOLLOWING COMMENTS: | | | | | | 1. ADDITION/NEW CONSTRUCTION IN HISTORIC DISTRICT | | | REQUIRES APPROVAL BY THE HISTORIC PRESERVATION BOARD. | | | 2. PLANS ARE NOT DETAILED ENOUGH TO UNDERSTAND | | | REHABILITATION EFFORTS ON EXISTING HISTORIC STRUCTURES, | | | PLEASE PROVIDE CLARIFICATION. | | | 3. PROPOSED ADDITION DOES NOT COMPLY WITH SECTION | | | 94-49, SPECIFICALLY; | | | SETTING, ORIENTATION AND SETBACKS IS NOT COMPATIBLE | | | WITH DISTRICT UTILIZING INVERSE STEPPING OF BUILDING AS | | | PROPOSED | | | PROPORTION OF OPENINGS ARE NOT VISUALLY COMPATIBLE WITH | | | SURROUNDING BUILDINGS | | | RHYTHM OF SOLIDS TO VOIDS IS NOT VISUALLY COMPATIBLE | | | AND | | | THE SIZE, SCALE, MASS AND VOLUME OVERWHELMS THE | | | EXISTING STRUCTURES. | | | 2. DETAILED PLANS OF SHORING/SUPPORT SHALL BE SUBMITTED | | | PRIOR TO PERMITTING TO ENSURE NO DAMAGE OCCURS | | | | | | |
|
|
| |
Print |
|