Plan Review Details - Project Z15120017
| Plan Review Stops For Project Z15120017 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
05-10-2016 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
05-10-2016 |
Time |
21:25 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
05-10-2016 |
Time |
21:25 |
Sent To |
|
|
| Notes |
| 2016-05-10 21:37:49 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. YOUR COMMENT RESPONSE HAS ACKNOWLEDGED THE FOLLOWING | | | ORIGIANL COMMENT: THIS REVIEW IS A CURSORY REVIEW AS IT | | | RELATES TO THE SITE. IT IS NOT A REVIEW FOR FULL | | | COMPLIANCE WITH FLORIDA BUILDING CODE. THE FOLLOWING | | | COMMENTS ARE TO BE ADDRESSED FOR PERMITTING. | | | | | | 2. YOUR COMMENT RESPONSE REGARDING THE ACCESSIBLE | | | PARKING AND ACCESS TO THE AMENITIES BUILDING IS NOTED, | | | BUT FAILS TO ADDRESS THE COMMENT FULLY. THE PARKING | | | COMPUTATION TABLE ON SHEET FSP-1 STATES THAT 13 | | | ACCESSIBLE SPACES WILL BE PROVIDED ON THE 1ST LEVEL AND | | | 7 ACCESSIBLE PARKING SPACES WILL BE PROVIDED ON THE 2ND | | | LEVEL, BUT THE LOCATION OF THOSE SPACES ARE NOT SHOWN | | | ON SHEETS FSP-1, FSP-2, SP-1, LVL-2, LVL-3, THAT IS | | | SHOWN ON SHEET LVL-3 APPEAR TO BE LOCATED IN THE | | | PARKING GARAGE AT LVL-2. THOSE SHEETS ONLY SHOW 9 | | | ACCESSIBLE SPACES ON THE 1ST LEVEL AND NO ACCESSIBLE | | | PARKING SPACES ON THE 2ND LEVEL. THE MINIMUM NUMBER OF | | | ACCESSIBLE PARKING SPACES PROVIDED SHALL BE IN | | | ACCORDANCE WITH SECTION 208.2 OF FLORIDA ACCESSIBILITY | | | CODE. | | | | | | 3. YOUR COMMENT RESPONSE HAS ACKNOWLEDGED THE FOLLOWING | | | ORIGIANL COMMENT: PER SECTION 208.2.4 OF FLORIDA | | | ACCESSIBILITY CODE, ONE IN EVERY SIX ACCESSIBLE SPACES | | | (AT LEAST ONE) IN A PARKING STRUCTURE, SHALL BE VAN | | | ACCESSIBLE AND DESIGNED IN ACCORDANCE WITH SECTION OF | | | 502 OF FLORIDA ACCESSIBILITY CODE (VERTICAL CLEARANCE | | | NOT LESS THAN 98 INCHES AT SPACE AND VEHICULAR ACCESS | | | ROUTE) | | | | | | 4. YOUR COMMENT RESPONSE HAS ACKNOWLEDGED THE FOLLOWING | | | ORIGIANL COMMENT: WHEN SUBMITTED FOR BUILDING PERMIT, | | | THE PLANS SHALL SHOW THAT THE TYPE OF CONSTRUCTION FOR | | | THE BUILDINGS WILL BE IN ACCORDANCE WITH THE HEIGHT, | | | AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE | | | FLORIDA BUILDING CODE | | | | | | 5. YOUR COMMENT RESPONSE HAS ACKNOWLEDGED THE FOLLOWING | | | ORIGIANL COMMENT: WHEN SUBMITTED FOR BUILDING PERMIT, | | | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF | | | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF | | | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE | | | VERIFIED. | | | | | | 6. YOUR COMMENT RESPONSE HAS ACKNOWLEDGED THE FOLLOWING | | | ORIGIANL COMMENT: THE PARKING GARAGE APPEARS TO BE AN | | | OPEN "VENTED" GARAGE. THE REMAINDER OF THIS COMMENT | | | ONLY APPLIES IF IT IS IN FACT AN ENCLOSED PARKING | | | GARAGE. IF THE PARKING GARAGE DOES NOT HAVE WALL | | | OPENINGS, OR SUFFICIENT WALL OPENINGS TO MEET THE | | | DEFINITION OF AN OPEN PARKING GARAGE, IT WILL BE | | | CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE | | | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED | | | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR | | | OTHER APPROVED METHODS. | | | | | | 5. YOUR COMMENT RESPONSE HAS ACKNOWLEDGED THE FOLLOWING | | | ORIGIANL COMMENT: SEPARATE PERMITS REQUIRED. ALL | | | APPLICABLE PERMITS AND SUB-PERMITS MUST BE OBTAINED | | | BEFORE COMMENCING THE WORK. SEPARATE PERMITS, PLANS AND | | | FEES, ARE REQUIRED FOR SIGNS, SWIMMING POOLS AND SPAS, | | | GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, FIRE | | | SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, GREASE | | | INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, SITE | | | IRRIGATION, ETC. | | | | | | 6. YOUR COMMENT RESPONSE HAS ACKNOWLEDGED THE FOLLOWING | | | ORIGIANL COMMENT: EACH SEPARATE BUILDING SHALL HAVE A | | | SEPARATE ADDRESS. FOR STREET ADDRESSING, CONTACT | | | MICHAEL ORIO, GIS SUPPORT SPECIALIST, AT (561) 494 | | | 1080, OR BY EMAIL: [email protected] | | | | | | 7. YOUR COMMENT RESPONSE HAS ACKNOWLEDGED THE FOLLOWING | | | ORIGIANL COMMENT: THIS PROJECT WILL BE SUBJECT TO ART | | | IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE ON THE | | | PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP | | | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC | | | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
01-12-2016 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
01-12-2016 |
Time |
20:53 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
01-12-2016 |
Time |
20:53 |
Sent To |
|
|
| Notes |
| 2016-01-12 21:02:26 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. THE CLOSEST PARKING SPACES TO THE AMENITIES BUILDING | | | THAT IS SHOWN ON SHEET LVL-3 APPEAR TO BE LOCATED IN | | | THE PARKING GARAGE AT LVL-2. THE CLOSEST SPACES TO THE | | | AMENITIES BUILDING SHALL BE ACCESSIBLE PARKING SPACES. | | | PER SECTION 208.3 OF FLORIDA ACCESSIBILITY CODE, | | | ACCESSIBLE PARKING SPACES ARE TO BE LOCATED ON THE | | | SHORTEST POSSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING | | | TO AN ACCESSIBLE ENTRANCE FOR EACH BUILDING. THE DESIGN | | | OF ACCESSIBLE PARKING SPACES SHALL COMPLY WITH SECTION | | | 502 OF FLORIDA ACCESSIBILITY CODE | | | | | | 3. PER SECTION 208.2.4 OF FLORIDA ACCESSIBILITY CODE, | | | ONE IN EVERY SIX ACCESSIBLE SPACES (AT LEAST ONE) IN A | | | PARKING STRUCTURE, SHALL BE VAN ACCESSIBLE AND DESIGNED | | | IN ACCORDANCE WITH SECTION OF 502 OF FLORIDA | | | ACCESSIBILITY CODE (VERTICAL CLEARANCE NOT LESS THAN 98 | | | INCHES AT SPACE AND VEHICULAR ACCESS ROUTE) | | | | | | 4. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL | | | SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS | | | WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND | | | OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA | | | BUILDING CODE | | | | | | 5. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH | | | ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND | | | OPENING PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 OF | | | THE FLORIDA BUILDING CODE SHALL BE VERIFIED. | | | | | | 6. THE PARKING GARAGE APPEARS TO BE AN OPEN "VENTED" | | | GARAGE. THE REMAINDER OF THIS COMMENT ONLY APPLIES IF | | | IT IS IN FACT AN ENCLOSED PARKING GARAGE. IF THE | | | PARKING GARAGE DOES NOT HAVE WALL OPENINGS, OR | | | SUFFICIENT WALL OPENINGS TO MEET THE DEFINITION OF AN | | | OPEN PARKING GARAGE, IT WILL BE CONSIDERED AN ENCLOSED | | | PARKING GARAGE AND MUST HAVE EXHAUST SYSTEMS. THE | | | EXHAUST SYSTEMS SHALL BE DESIGNED TO MINIMIZE NOISE | | | LEVELS USING INLINE FAN SILENCERS OR OTHER APPROVED | | | METHODS. | | | | | | 5. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 6. EACH SEPARATE BUILDING SHALL HAVE A SEPARATE | | | ADDRESS. FOR STREET ADDRESSING, CONTACT MICHAEL ORIO, | | | GIS SUPPORT SPECIALIST, AT (561) 494 1080, OR BY EMAIL: | | | [email protected] | | | | | | 7. THIS PROJECT WILL BE SUBJECT TO ART IN PUBLIC PLACES | | | (AIPP) ASSESSMENT. FOR ADVICE ON THE PROVISION OF | | | PUBLIC ARTWORK IN LIEU OF THE AIPP ASSESSMENT, CONTACT | | | SYBILLE WELTER, ART IN PUBLIC PLACES COORDINATOR, AT | | | (561) 822-1521, OR BY EMAIL: [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
3 |
Status |
P |
Date |
06-03-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
06-03-2016 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
06-03-2016 |
Time |
08:41 |
Sent To |
|
|
| Notes |
| 2016-06-03 08:49:19 | NO ADDITIONAL COMMENTS. |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
05-11-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
05-11-2016 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
05-11-2016 |
Time |
08:19 |
Sent To |
|
|
| Notes |
| 2016-05-11 08:19:12 | CITY OF WEST PALM BEACH | | | ENGINEERING DEPARTMENT | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. PLEASE SUBMIT ESTIMATES FOR THE SOLID WASTE | | | COLLECTION YARDAGE. | | | | | | 2. AS PREVIOUSLY REQUESTED, PROVIDE AN AUTOTURN | | | ANALYSIS DEMONSTRATING THE SOLID WASTE COLLECTION | | | VEHICLE CAN ACCESS THE PROPOSED DUMPSTER / COMPACTOR | | | LOCATIONS AT THE NORTHEAST CORNER OF THE PROPERTY AND | | | WITHIN THE PARKING GARAGE. THE TRASH | | | DUMPSTER/COMPACTORS MUST LOCATED IN AREAS EASILY | | | SERVICED BY THE CITY SANITATION EQUIPMENT AND MANPOWER | | | PER SECTION 74-35(A)(5) OF THE CODE OF ORDINANCES. IF A | | | ROLL-OFF COMPACTOR IS PROPOSED, PLEASE PROVIDE A LETTER | | | FROM THE PRIVATE PROVIDER VERIFYING THAT THEY CAN | | | PROVIDE SERVICE WITH THE CONFIGURATION SHOWN ON THE | | | PLANS. | | | | | | 3. DETAILS SHEETS WILL NEED TO UTILIZE STANDARD CITY OF | | | WEST PALM BEACH DETAILS, WHICH MAY BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 4. PLEASE SHOW THE SIGHT TRIANGLES ON THE GROUND FLOOR | | | LANDSCAPING PLAN FOR THE INTERSECTIONS AND VEHICULAR | | | EXITS. (SECTION 94-305E, CODE OF ORDINANCES) | | | | | | 5. EXISTING UTILITY SERVICE LINES, IF NOT UTILIZED BY | | | THE SITE REDEVELOPMENT, ARE TO BE REMOVED BACK TO THE | | | MAIN. (SECTION 2.23 OF THE CITY RIGHT OF WAY | | | CONSTRUCTION STANDARDS MANUAL) PLEASE ADD THE | | | APPROPRIATE NOTES TO THE CONSTRUCTION PLAN. | | | | | | 6. AS MENTIONED IN OUR ORIGINAL COMMENTS, PLEASE | | | RELOCATE THE PROPOSED MASTER METER ADJACENT TO PUBLIC | | | RIGHT-OF-WAY. ON-SITE SUB-METERS WILL REQUIRE APPROVAL | | | FROM CITY UTILITIES CUSTOMER SERVICE DIVISION. | | | | | | 7. AS MENTIONED IN OUR ORIGINAL COMMENTS, PER SECTION | | | 2.21.2 OF THE CITY RIGHT OF WAY STANDARDS MANUAL, | | | PROJECTS WHICH DISTURB 40% OR MORE OF A ROADWAY (LINEAR | | | FOOTAGE) PER BLOCK WILL BE REQUIRED TO MILL AND | | | RESURFACE THE ENTIRE BLOCK. PLEASE INCLUDE MILLING AND | | | RESURFACING OF THE HAMPTON ROAD ON THE CONSTRUCTION | | | PLANS. | | | | | | 8. PLEASE REVISE THE DRIVEWAY APRONS ON THE ALLEY TO | | | MEET THE CITY?S ENGINEERING DESIGN STANDARDS. AN | | | EXCEPTION TO THE STANDARD MAY BE REQUESTED. HTTP://WPB. | | | ORG/ENGINEERING/ENGINEERING-SERVICES/ENGINEERING-STANDA | | | RDS/ | | | | | | 9. PLEASE ELIMINATE THE EASTERN DRIVEWAY ON HAMPTON. | | | THE PROPOSED ENTRANCE IS DOES NOT MEET THE MINIMUM | | | DISTANCES LISTED IN SECTION 94-313(2) OF THE CITY?S | | | CODE OF ORDINANCES. | | | | | | 10. PLEASE RE-EVALUATE THE PARKING CIRCULATION PLAN. | | | THE SOUTHEASTERN RETAIL PARKING APPEARS TO UTILIZE | | | HAMPTON AVENUE AS PART OF THE INTERNAL CIRCULATION | | | PLAN. | | | | | | 11. PLEASE CHECK THE RESIDENTIAL PARKING TOTALS. IN THE | | | PARKING GARAGE, THE PLANS SHOW 269 PARKING SPOTS ON | | | LEVEL 1 AND 288 SPOTS ON LEVEL 2 (557 SPOTS). SOME OF | | | THESE SPOTS WILL NEED TO BE ELIMINATED TO COMPLY WITH | | | CODE OF ORDINANCES SECTION 94-111, WHICH REQUIRED A | | | MINIMUM 3 FT BACK UP AREA AT THE TERMINUS OF ANY | | | DEAD-END DRIVE AISLE PLUS THE EQUIVALENT OF ONE PARKING | | | SPACE AS A DEDICATE PULL-IN AREA FOR TURNING AROUND. | | | THE PARKING CALCULATIONS SHOW THAT 625 SPACES WILL BE | | | PROVIDED IN THE GARAGE. | | | | | | 12. THE PLAN ALSO SHOWS 24 SURFACE PARKING SPOTS ON | | | SOUTH DIXIE. HAVE THESE SPOTS BEEN APPROVED BY FDOT? | | | | | | 13. PLEASE ADD STREET NAMES TO ALL PLANS. | | | | | | 14. PLEASE PROVIDE UTILITY CROSSING INFORMATION. | | | | | | 15. PLEASE PROVIDE FIRE HYDRANT FLOW TEST DATA FROM | | | EXISTING FIRE HYDRANT ON S DIXIE HWY. | | | | | | 16. PLEASE LABEL UTILITY PIPE SIZE AND MATERIAL. | | | | | | 17. PLEASE MOVE THE PROPOSED DDCV, REDUCER ASSEMBLY, | | | AND METER VAULT CLOSER TO THE POINT OF | | | CONNECTION/ROADWAY R/W. | | | | | | 18. PLEASE PROVIDE ENGINEERING/MEP CALCULATION FOR THE | | | PROPOSED 8? WM SIZING ON HAMPTON ROAD. | | | | | | 19. PLEASE PROVIDE PROFILE OF THE PROPOSED 8" WM FROM | | | THE TAP/POINT OF CONNECTION ON S DIXIE @ HAMPTON ROAD | | | TO THE METER VAULT. PLEASE CALL OUT THE POINT OF | | | SERVICE (WATER). | | | | | | 20. PLEASE SHOW THE EXISTING 6" WM ON HAMPTON ROAD. IT | | | IS THE CITY'S PREFERENCE NOT TO HAVE PARALLEL WATER | | | MAINS AND WILL BE REVIEWING THE NEED FOR MAINTAINING | | | (2) ACTIVE MAINS ON HAMPTON ROAD. | | | | | | 21. PLEASE LABEL THE SIZE AND MATERIAL OF EXISTING | | | WATER MAIN AND WATER SERVICE CONNECTIONS ON S DIXIE | | | HWY. RECORD INFORMATION INDICATES THAT THE EXISTING | | | WATER MAIN ON S DIXIE IS 8" CIP. | | | | | | 22. PLEASE PROVIDE ENGINEERING/MEP CALCULATION FOR THE | | | PROPOSED 8? GRAVITY MAIN SIZING ON HAMPTON ROAD. | | | | | | 23. PLEASE CALL OUT THE POINT OF SERVICE (SEWER). CCTV | | | RECORD (VIDEO AND TV LOG) OF THE PROPOSED SAN SEWER | | | MAIN WITHIN THE ROADWAY R/W WILL BE REQUIRED AS PART OF | | | THE PROJECT CLOSE-OUT SUBMITTAL. | | | | | | GENERAL COMMENTS | | | | | | 1. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE | | | AVAILABLE AT HTTP://WWW.CO.PALM-BEACH.FL.US/NEWSROOM/08 | | | 14/08-26-14-FLOOD_MAPS.HTM. PLEASE REVIEW THE MAPS AND | | | VERIFY THAT THE NEW MAPS WILL NOT IMPACT THE PROPOSED | | | PROJECT. | | | | | | 2. FDOT APPROVAL WILL BE REQUIRED FOR THE DRAINAGE AND | | | DRIVEWAY CONNECTIONS OFF OF DIXIE. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING DIVISION OF THE PUBLIC | | | WORKS DEPARTMENT. THE ENGINEERING DEVELOPMENT APPROVAL | | | APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 2. SOLID WASTE YARDAGE WILL NEED TO BE VERIFIED AS PART | | | OF THE FINAL DESIGN TO VERIFY THAT THE DESIGN INCLUDES | | | APPROPRIATE NUMBER AND SIZE OF TRASH BINS. | | | | | | KELLY CRANFORD, P.E. | | | CAPITAL IMPROVEMENT PLAN MANAGER | | | [email protected] | | | 561-494-1098 (OFFICE) | | | | | | VINCE NOEL, PSM | | | CITY SURVEYOR / REAL ESTATE SUPERVISOR | | | [email protected] | | | 561-494-1096 | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | 561-494-1120 | | | [email protected] | | | | | | LAURA LE, PE | | | PUBLIC UTILITIES ENGINEER | | | 561-494-1093 | | | [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
01-13-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
01-13-2016 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
01-13-2016 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2016-01-13 12:33:52 | CITY OF WEST PALM BEACH | | | PUBLIC WORKS DEPARTMENT | | | | | | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL. | | | | | | 1. A DETAILED TRAFFIC ANALYSIS WILL BE REQUIRED FOR | | | THIS PROJECT SHOWING HOW THE PROPOSED DEVELOPMENT WILL | | | AFFECT THE TRAFFIC VOLUME AND SURROUNDING LOCAL | | | ROADWAYS. INCLUDE TRAFFIC ACCIDENT DATA FOR AFFECTED | | | STREET CORRIDORS. ESTIMATE INCREASED OR DECREASED | | | POTENTIAL. SAFETY IMPROVEMENTS SHALL BE RECOMMENDED | | | WHERE NECESSARY. | | | | | | 2. REGARDING THE TRAFFIC IMPACT ANALYSIS: | | | | | | A. THE TRIP DISTRIBUTION OF 47% NORTH AND 53% SOUTH | | | SEEMS TO BE COUNTER INTUITIVE. PLEASE JUSTIFY WHY MORE | | | OF THE TRIPS ARE ASSUMED TO BE GOING SOUTH. BOTH | | | DOWNTOWN AND I-95 (THROUGH BELVEDERE) ARE ACCESSIBLE TO | | | THE NORTH OF THE PROJECT. | | | | | | B. THE ANALYSIS SHOWS OVER 1,070 DAILY TRIPS USE | | | HAMPTON ROAD TO ENTER / EXIT THE PROJECT. HAMPTON IS A | | | SMALL ROAD WITH AN UNSIGNALIZED INTERSECTION AT DIXIE. | | | WE ARE CONCERNED THAT THIS INTERSECTION (AND HAMPTON IN | | | GENERAL) MAY BE OVERBURDENED AS A RESULT OF THIS | | | PROJECT. | | | | | | C. THE ANALYSIS INDICATES THE PERCENTAGE OF PEAK HOUR | | | TRIPS FOR THIS PROJECT WILL BE LESS THAN 7.5% OF THE | | | TOTAL DAILY TRIPS. THIS APPEARS TO BE VERY LOW FOR A | | | PRIMARILY RESIDENTIAL PROJECT. PLEASE PROVIDE THE | | | ASSUMPTIONS USED TO ARRIVE AT THE NUMBER OF DAILY | | | TRIPS. | | | | | | 3. PLEASE SUBMIT ESTIMATES FOR THE PEAK POTABLE WATER | | | DEMAND, SANITARY SEWER FLOW, AND SOLID WASTE COLLECTION | | | YARDAGE. | | | | | | 4. A MAINTENANCE AGREEMENT WILL BE REQUIRED FOR THE | | | NON-STANDARD ELEMENTS (TREES AND TREE GRATES; PAVERS, | | | ETC.) PROPOSED WITHIN GARDENIA RIGHT-OF-WAY. | | | | | | 5. PLEASE PROVIDE AN AUTOTURN ANALYSIS DEMONSTRATING | | | THE SOLID WASTE COLLECTION VEHICLE CAN ACCESS THE | | | PROPOSED DUMPSTER AND COMPACTOR LOCATIONS. THE TRASH | | | DUMPSTER/COMPACTORS MUST LOCATED IN AREAS EASILY | | | SERVICED BY THE CITY SANITATION EQUIPMENT AND MANPOWER | | | PER SECTION 74-35(A)(5) OF THE CODE OF ORDINANCES. IF A | | | ROLL-OFF COMPACTOR IS PROPOSED, PLEASE PROVIDE A LETTER | | | FROM THE PRIVATE PROVIDER VERIFYING THAT THEY CAN | | | PROVIDE SERVICE WITH THE CONFIGURATION SHOWN ON THE | | | PLANS. | | | | | | 6. PRIOR TO THE START OF CONSTRUCTION, APPROVAL IS | | | REQUIRED FROM THE FLORIDA DEPARTMENT OF TRANSPORTATION | | | (FDOT) FOR THE DRAINAGE CONNECTION TO THE DIXIE SYSTEM. | | | | | | 7. THE CITY WILL EVALUATE THE CONDITION OF THE EXISTING | | | OFF-SITE UTILITIES WITHIN THE NEXT 30 DAYS. IT IS | | | RECOMMENDED THAT THE RESULT OF THE EVALUATION BE | | | INCORPORATED INTO FINAL POTABLE WATER AND SANITARY | | | DESIGN. | | | | | | 8. WHERE ARE THE GREASE TRAPS PROPOSED TO BE LOCATED | | | FOR THE RESTAURANTS? THE DESIGN MUST COMPLY WITH CITY | | | ENGINEERING DESIGN STANDARD GS-7 OR GS-7.1. SAMPLING | | | PORTS MUST BE LOCATED ON THE EXTERIOR OF THE BUILDING. | | | HTTP://WPB.ORG/ENGINEERING/ENGINEERING-SERVICES/ENGINEE | | | RING-STANDARDS/ | | | | | | 9. PLEASE INDICATE WHERE THE MASTER METER WILL BE | | | LOCATED FOR THE PROJECT. THE METER WILL NEED TO BE | | | LOCATED WITHIN THE CITY RIGHT-OF-WAY OR WITHIN AN | | | EASEMENT IMMEDIATELY ADJACENT TO THE RIGHT-OF-WAY. | | | | | | 10. THE CITY WILL NOT BE TAKING OWNERSHIP OF UTILITIES | | | LOCATED WITHIN THE PARCEL WHICH SERVE ONLY THIS | | | DEVELOPMENT. | | | | | | 11. ARE THE OUTPARCEL PROPOSED TO BE LEASED OR FEE | | | SIMPLE? | | | | | | 12. PLEASE NOTE THAT THE AVAILABLE WATER PRESSURE | | | WITHIN THE CITY MAY NOT BE ACCEPTABLE AT ELEVATIONS | | | HIGHER THAN THE 2ND FLOOR. WE RECOMMEND THAT A | | | LONG-TERM PRESSURE STUDY BE PERFORMED ON THE POTABLE | | | WATER LINES PRIOR TO FINALIZATION OF THE DESIGN. | | | | | | 13. VERIFY THAT THE PROPOSED SIZE AND QUANTITY OF TRASH | | | BINS IS APPROPRIATE FOR THE WASTE YARDAGE ANTICIPATED | | | TO BE GENERATED BY THE COMPLEX. CONSIDER USING A | | | COMPACTOR TO REDUCE THE YARDAGE OF WASTE THAT WILL NEED | | | TO BE COLLECTED. IF A COMPACTOR LARGER THAN 8 CUBIC | | | YARDS IS PROPOSED, PLEASE PROVIDE A LETTER FROM THE | | | APPROPRIATE PRIVATE SERVICE PROVIDER STATING THEY HAVE | | | REVIEWED THE PROPOSED SITE PLAN AND WILL BE ABLE TO | | | SERVICE THE COMPACTOR IN THE PROPOSED LOCATION. | | | | | | 14. PER SECTION 2.21.2 OF THE CITY RIGHT OF WAY | | | STANDARDS MANUAL, PROJECTS WHICH DISTURB 40% OR MORE OF | | | A ROADWAY (LINEAR FOOTAGE) PER BLOCK WILL BE REQUIRED | | | TO MILL AND RESURFACE THE ENTIRE BLOCK. PLEASE INCLUDE | | | MILLING AND RESURFACING OF THE HAMPTON ROAD ON THE | | | CONSTRUCTION PLANS. | | | | | | 15. PLEASE REVISE THE DRIVEWAY APRONS ON THE ALLEY TO | | | MEET THE CITY?S ENGINEERING DESIGN STANDARDS. HTTP://WP | | | B.ORG/ENGINEERING/ENGINEERING-SERVICES/ENGINEERING-STAN | | | DARDS/ | | | | | | 16. PLEASE SHOW THE SIGHT TRIANGLES ON THE GROUND FLOOR | | | LANDSCAPING PLAN FOR THE INTERSECTIONS AND VEHICULAR | | | EXITS. (SECTION 94-305E, CODE OF ORDINANCES) | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED IN THE PRIOR | | | TO ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. A SEPARATE SUBMITTAL WILL BE REQUIRED TO THE | | | ENGINEERING DIVISION OF THE PUBLIC WORKS DEPARTMENT FOR | | | ENGINEERING DEVELOPMENT APPROVAL. THE ENGINEERING | | | DEVELOPMENT APPROVAL APPLICATION FORMS CAN BE | | | DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 2. A SEPARATE SUBMITTAL WILL BE REQUIRED TO THE | | | ENGINEERING DIVISION OF THE PUBLIC WORKS DEPARTMENT FOR | | | PLAT APPROVAL. PLEASE CONTACT VINCE NOEL AT | | | [email protected] TO GET A COPY OF THE PLAT APPLICATION. | | | | | | 3. SOLID WASTE YARDAGE WILL NEED TO BE ESTIMATED AS | | | PART OF THE FINAL DESIGN TO VERIFY THAT THE DESIGN | | | INCLUDES APPROPRIATE NUMBER AND SIZE OF TRASH BINS. | | | | | | 4. THE PROPOSED NEW CONNECTIONS TO THE CITY?S EXISTING | | | STORMWATER STRUCTURES MAY NECESSITATE REHABILITATION OF | | | THE MANHOLES. | | | | | | 5. INDICATE ON THE PLANS WHICH PORTIONS OF THE POTABLE | | | WATER, SANITARY SEWER, AND STORMWATER SYSTEM WILL | | | REMAIN PUBLICALLY OWNED AND WHICH SECTIONS WILL BE | | | MAINTAINED BY THE APPLICANT. TYPICALLY, THE CITY'S | | | OWNERSHIP STOPS AT THE RIGHT-OF-WAY LINE UNLESS | | | EXTENUATING CIRCUMSTANCES REQUIRED THE OWNERSHIP | | | DIVISION TO TAKE PLACE AT ANOTHER LOCATION. | | | | | | 6. DETAILS SHEETS WILL NEED TO UTILIZE STANDARD CITY OF | | | WEST PALM BEACH DETAILS WHICH MAY BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | KELLY CRANFORD, P.E. | | | CIP MANAGER | | | [email protected] | | | 561-494-1098 (OFFICE) | | | | | | VINCE NOEL, PSM | | | CITY SURVEYOR / REAL ESTATE SUPERVISOR | | | [email protected] | | | 561-494-1096 | | | | | | BRIAN COLLINS, PE | | | CITY TRAFFIC ENGINEER | | | [email protected] | | | 561-494-1040 | | | | | | FERDINAND RIVERA | | | PUBLIC WORKS OPERATIONS MANAGER | | | [email protected] | | | 561-822-2076 | | | | | | TRACY WARD, PE | | | CITY STORMWATER ENGINEER | | | 561-494-1120 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
06-06-2016 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
06-06-2016 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
06-06-2016 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2016-06-06 14:19:46 | 3RD REVIEW RESPONSE | | | | | | AFTER A REVIEW OF THE PPRC RESPONSE LETTER DATED MAY | | | 27, 2016, FROM CHRIS BARRY, SENIOR PLANNER, URBAN | | | DESIGN KILDAY STUDIOS, TO JOHN ROACH SENIOR PLANNER, | | | THE PREVIOUSLY SUBMITTED FIRE PREVENTION BUREAU | | | COMMENTS HAVE BEEN ADDRESSED. | | | | | | THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES | | | NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
05-05-2016 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
05-05-2016 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
05-05-2016 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2016-05-05 15:24:34 | ON REVIEW OF THE RE-SUBMITTAL, THE PREVIUOS COMMENTS BY | | | FIRE REMAIN APPLICABLE. | | | | | | 2ND REVIEW: | | | | | | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2 | | | TEMPORARY OFFICES AND SHEDS SHALL BE SEPARATED FROM | | | ADJACENT TRAILERS OR STRUCTURES IN ACCORDANCE WITH | | | TABLE 4.2.1. PER TABLE 4.2.1: | | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. ALL PARKING STRUCTURES SHALL COMPLY WITH NFPA 88A, | | | PARKING STRUCTURES AND NFPA 101, THE LIFE SAFETY CODE, | | | INCLUDING MORE SPECIFICALLY, CHAPTER 42 STORAGE | | | OCCUPANCIES (PARKING STRUCTURES) | | | | | | 7. THE SEPARATION AND OPENING PROTECTION BETWEEN THE | | | PARKING GARAGE AND RESIDENTIAL AREAS SHALL BE IN | | | ACCORDANCE AND COMPLIANCE WITH THE SPECIFIC AND MOST | | | STRINGENT PROVISION REQUIREMENT OF EITHER CHAPTER OF | | | THE FIRE CODE. | | | | | | THESE BUILDINGS IS FUNCTIONING AS A MULTIUSE OCCUPANCY. | | | INDICATE IF THE BUILDING IS DESIGNED FOR MIXED USE | | | (NON-SEPARATED) OR SEPARATED USE PER SECTION 6.1.14.2.1 | | | OF NFPA 101 FLORIDA EDITION 2009. FOR NON-SEPARATED | | | MIXED USE OCCUPANCIES, THE MOST STRINGENT FIRE AND LIFE | | | SAFETY REQUIREMENTS OF EACH OCCUPANCY SHALL APPLY TO | | | THE BUILDING. | | | | | | 8. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA | | | 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS | | | STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE | | | BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE | | | BEING CONSTRUCTED. SEPARATE SHOP DRAWINGS, ARE REQUIRED | | | TO BE SUBMITTED, REVIEWED AND APPROVED BY THE FIRE | | | PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | | | | | IT IS STRONGLY RECOMMENDED FOR EACH BUILDING HAVE IT'S | | | OWN FIRE ALARM PANEL AND SYSTEM. | | | | | | FOR THE PROPOSED FIRE PUMP(S) , WHAT IS(ARE) THE | | | PRIMARY AND SECONDARY POWER SOURCES? | | | | | | 9. A CLASS A NFPA 72 COMPLIANT MONITORED FIRE ALARM | | | SYSTEM IS REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP | | | DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED AND | | | APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY | | | INSTALLATION. | | | | | | 10. ALL EXIT DISCHARGE LOCATIONS SHALL BE CLEARLY | | | ILLUSTRATED ON THE PLAN. | | | | | | 11. ALL ILLUMINATED EXIT SIGNS AND EMERGENCY LIGHTING | | | EQUIPMENT SHALL BE ILLUSTRATED ON THE PLAN. | | | | | | IF AN EMERGENCY POWER GENERATOR IS PROPOSED, WHAT IS | | | (ARE) THE PRIMARY AND SECONDARY POWER SOURCES? | | | | | | 12. TACTILE SIGNAGE SHALL BE INSTALLED AT ALL EXIT | | | DOORS. | | | | | | 13. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | A REVIEW OF THE SUBMITTED LIFE SAFETY PLAN ON SHEET A | | | 1.0- 3.0 SHOWS THE EXIT SEPARATION OF THE EXIT | | | STAIRWELLS THAT DOES NOT COMPLY WITH THE LIFE SAFETY | | | CODE. THE SEPARATION OF THE EXITS, 50' SHALL BE | | | MEASURED EXIT DOOR TO EXIT DOOR. | | | | | | PER NFPA 101, CHAPTER 7, 7.5.1.3.2, WHERE TWO EXITS, | | | EXIT ACCESSES, OR EXIT DISCHARGES ARE REQUIRED, THEY | | | SHALL BE LOCATED AT A DISTANCE FROM ONE ANOTHER NOT | | | LESS THAN ONE-HALF THE LENGTH OF THE MAXIMUM OVERALL | | | DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE | | | SERVED, MEASURED IN A STRAIGHT LINE BETWEEN THE NEAREST | | | EDGE OF THE EXITS, EXIT ACCESSES, OR EXIT DISCHARGES. | | | | | | 14. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. ADDITIONAL HYDRANTS APPEAR TO REQUIRED | | | AT THE FRONT ACCESS WAY. COORDINATION WITH THE | | | PREVENTION BUREUA IS STRONGLY ENCOURAGE. | | | | | | 15. ALL FIRE DEPARTMENT SPRINKLER SYSTEM CONNECTIONS | | | (FDC,S) FOR THE PROJECT SHALL BE IDENTIFIED AND | | | COORDINATED WITH THE BUREAU OF FIRE PREVENTION. | | | ADDITIONAL FDC'S APPEAR TO REQUIRED AT THE FRONT OF | | | EACH BUILDING. COORDINATION WITH THE PREVENTION BUREUA | | | IS STRONGLY ENCOURAGE. | | | | | | 16. ALL FIRE WATER MAINS, SIZES AND THEIR VALVE | | | ASSEMBLIES SHALL BE CLEARLY IDENTIFIED AND ILLUSTRATED | | | ON THE PLAN. TWO SEPARATE, SEPARATED WATER SUPPLIES | | | SHALL BE CLEARLY INDICATED ON THE PLAN. | | | | | | ALL SITE FIRE LINES SHALL COMPLY WITH NFPA 24 AND BE | | | INSPECTED BY THE FIRE PREVENTION BUREAU. | | | | | | 17. A FIRE LOAD CALCULATION IS REQUIRED TO ENSURE THAT | | | THE EXISTING OR PROPOSED WATER SUPPLY IS AVAILABLE FOR | | | FIRE PROTECTION OF THE PROJECT. | | | | | | 18. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | | BUILDING. | | | | | | ANY GATES SHALL BE PROVIDED WITH KNOX KEY ACCESS LOCKS, | | | PADLOCKS AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 19. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM. | | | | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER?S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 20. COMMAND ROOM | | | | | | THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | 1. SHALL BE A MINIMUM OF 200 FT SQUARED WITH A MINIMUM | | | DIMENSION OF 10 FT. | | | 2. THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | 3. A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | 4. SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS AND THE LOCATION | | | OF FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS | | | 5. A WORK TABLE. | | | 6. IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | 7. THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | 8. ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION OF | | | THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | 9. STATUS INDICATORS AND CONTROLS FOR AIR DISTRIBUTION | | | SYSTEMS. | | | 10. CONTROLS FOR UNLOCKING STAIRWAY DOORS | | | SIMULTANEOUSLY | | | 11. SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | 12. EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | 13. FIRE PUMP STATUS INDICATORS | | | 14. GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | 15. PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | 16. CONTROLS REQUIRED FOR SMOKE CONTROL | | | 17. ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1. | | | 18. ELEVATOR EMERGENCY OR STANDBY POWER SELECTOR | | | SWITCH(ES), WHERE EMERGENCY OR STANDBY POWER IS | | | PROVIDED | | | | | | 21. RADIO | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | MAINTAIN A MINIMUM RADIO SIGNAL STRENGTH OF 102.0 DBM | | | FOR THE RADIO SYSTEM USED BY WEST PALM BEACH FIRE | | | RESCUE. IF THE MINIMUM CANNOT BE MAINTAINED, A | | | BI-DIRECTIONAL AMPLIFIED SYSTEM SHALL BE INSTALLED WITH | | | A MINIMUM 2-HOUR RUN TIME BATTERY BACK-UP. | | | | | | 22. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 23. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
01-08-2016 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
01-08-2016 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
01-07-2016 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2016-01-07 17:06:15 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2 | | | TEMPORARY OFFICES AND SHEDS SHALL BE SEPARATED FROM | | | ADJACENT TRAILERS OR STRUCTURES IN ACCORDANCE WITH | | | TABLE 4.2.1. PER TABLE 4.2.1: | | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. ALL PARKING STRUCTURES SHALL COMPLY WITH NFPA 88A, | | | PARKING STRUCTURES AND NFPA 101, THE LIFE SAFETY CODE, | | | INCLUDING MORE SPECIFICALLY, CHAPTER 42 STORAGE | | | OCCUPANCIES (PARKING STRUCTURES) | | | | | | 7. THE SEPARATION AND OPENING PROTECTION BETWEEN THE | | | PARKING GARAGE AND RESIDENTIAL AREAS SHALL BE IN | | | ACCORDANCE AND COMPLIANCE WITH THE SPECIFIC AND MOST | | | STRINGENT PROVISION REQUIREMENT OF EITHER CHAPTER OF | | | THE FIRE CODE. | | | | | | THESE BUILDINGS IS FUNCTIONING AS A MULTIUSE OCCUPANCY. | | | INDICATE IF THE BUILDING IS DESIGNED FOR MIXED USE | | | (NON-SEPARATED) OR SEPARATED USE PER SECTION 6.1.14.2.1 | | | OF NFPA 101 FLORIDA EDITION 2009. FOR NON-SEPARATED | | | MIXED USE OCCUPANCIES, THE MOST STRINGENT FIRE AND LIFE | | | SAFETY REQUIREMENTS OF EACH OCCUPANCY SHALL APPLY TO | | | THE BUILDING. | | | | | | 8. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM AND NFPA | | | 14 COMPLIANT WET STANDPIPE SYSTEM ARE REQUIRED FOR THIS | | | STRUCTURE. TEMPORARY STANDPIPES ARE REQUIRED WHEN THE | | | BUILDING REACHES THREE LEVELS OR THIRTY FEET WHILE | | | BEING CONSTRUCTED. SEPARATE SHOP DRAWINGS, ARE REQUIRED | | | TO BE SUBMITTED, REVIEWED AND APPROVED BY THE FIRE | | | PREVENTION BUREAU PRIOR TO ANY INSTALLATION. | | | | | | IT IS STRONGLY RECOMMENDED FOR EACH BUILDING HAVE IT'S | | | OWN FIRE ALARM PANEL AND SYSTEM. | | | | | | FOR THE PROPOSED FIRE PUMP(S) , WHAT IS(ARE) THE | | | PRIMARY AND SECONDARY POWER SOURCES? | | | | | | 9. A CLASS A NFPA 72 COMPLIANT MONITORED FIRE ALARM | | | SYSTEM IS REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP | | | DRAWINGS, ARE REQUIRED TO BE SUBMITTED, REVIEWED AND | | | APPROVED BY THE FIRE PREVENTION BUREAU PRIOR TO ANY | | | INSTALLATION. | | | | | | 10. ALL EXIT DISCHARGE LOCATIONS SHALL BE CLEARLY | | | ILLUSTRATED ON THE PLAN. | | | | | | 11. ALL ILLUMINATED EXIT SIGNS AND EMERGENCY LIGHTING | | | EQUIPMENT SHALL BE ILLUSTRATED ON THE PLAN. | | | | | | IF AN EMERGENCY POWER GENERATOR IS PROPOSED, WHAT IS | | | (ARE) THE PRIMARY AND SECONDARY POWER SOURCES? | | | | | | 12. TACTILE SIGNAGE SHALL BE INSTALLED AT ALL EXIT | | | DOORS. | | | | | | 13. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | A REVIEW OF THE SUBMITTED LIFE SAFETY PLAN ON SHEET A | | | 1.0- 3.0 SHOWS THE EXIT SEPARATION OF THE EXIT | | | STAIRWELLS THAT DOES NOT COMPLY WITH THE LIFE SAFETY | | | CODE. THE SEPARATION OF THE EXITS, 50' SHALL BE | | | MEASURED EXIT DOOR TO EXIT DOOR. | | | | | | PER NFPA 101, CHAPTER 7, 7.5.1.3.2, WHERE TWO EXITS, | | | EXIT ACCESSES, OR EXIT DISCHARGES ARE REQUIRED, THEY | | | SHALL BE LOCATED AT A DISTANCE FROM ONE ANOTHER NOT | | | LESS THAN ONE-HALF THE LENGTH OF THE MAXIMUM OVERALL | | | DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE | | | SERVED, MEASURED IN A STRAIGHT LINE BETWEEN THE NEAREST | | | EDGE OF THE EXITS, EXIT ACCESSES, OR EXIT DISCHARGES. | | | | | | 14. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. ADDITIONAL HYDRANTS APPEAR TO REQUIRED | | | AT THE FRONT ACCESS WAY. COORDINATION WITH THE | | | PREVENTION BUREUA IS STRONGLY ENCOURAGE. | | | | | | 15. ALL FIRE DEPARTMENT SPRINKLER SYSTEM CONNECTIONS | | | (FDC,S) FOR THE PROJECT SHALL BE IDENTIFIED AND | | | COORDINATED WITH THE BUREAU OF FIRE PREVENTION. | | | ADDITIONAL FDC'S APPEAR TO REQUIRED AT THE FRONT OF | | | EACH BUILDING. COORDINATION WITH THE PREVENTION BUREUA | | | IS STRONGLY ENCOURAGE. | | | | | | 16. ALL FIRE WATER MAINS, SIZES AND THEIR VALVE | | | ASSEMBLIES SHALL BE CLEARLY IDENTIFIED AND ILLUSTRATED | | | ON THE PLAN. TWO SEPARATE, SEPARATED WATER SUPPLIES | | | SHALL BE CLEARLY INDICATED ON THE PLAN. | | | | | | ALL SITE FIRE LINES SHALL COMPLY WITH NFPA 24 AND BE | | | INSPECTED BY THE FIRE PREVENTION BUREAU. | | | | | | 17. A FIRE LOAD CALCULATION IS REQUIRED TO ENSURE THAT | | | THE EXISTING OR PROPOSED WATER SUPPLY IS AVAILABLE FOR | | | FIRE PROTECTION OF THE PROJECT. | | | | | | 18. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS | | | BUILDING. | | | | | | ANY GATES SHALL BE PROVIDED WITH KNOX KEY ACCESS LOCKS, | | | PADLOCKS AND/OR SWITCHES FOR 24 HOUR EMERGENCY ACCESS. | | | | | | 19. ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 | | | KEYWAY SYSTEM. | | | | | | ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE FIGHTER?S | | | EMERGENCY OPERATIONS REQUIREMENTS OF ASME A17.1/CSA | | | B44, SAFETY CODE FOR ELEVATORS. | | | | | | ANY BUILDING THAT IS MORE THAN THREE STORIES HIGH OR IN | | | WHICH THE VERTICAL DISTANCE BETWEEN THE BOTTOM TERMINAL | | | LANDING AND THE TOP TERMINAL LANDING EXCEEDS 25 FEET | | | MUST BE CONSTRUCTED TO CONTAIN AT LEAST ONE PASSENGER | | | ELEVATOR THAT IS OPERATIONAL AND WILL ACCOMMODATE AN | | | AMBULANCE STRETCHER 76 INCHES LONG AND 24 INCHES WIDE | | | IN THE HORIZONTAL POSITION. | | | | | | 20. COMMAND ROOM | | | | | | THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | 1. SHALL BE A MINIMUM OF 200 FT SQUARED WITH A MINIMUM | | | DIMENSION OF 10 FT. | | | 2. THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | 3. A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | 4. SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS AND THE LOCATION | | | OF FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS | | | 5. A WORK TABLE. | | | 6. IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | 7. THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | 8. ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION OF | | | THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | 9. STATUS INDICATORS AND CONTROLS FOR AIR DISTRIBUTION | | | SYSTEMS. | | | 10. CONTROLS FOR UNLOCKING STAIRWAY DOORS | | | SIMULTANEOUSLY | | | 11. SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | 12. EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | 13. FIRE PUMP STATUS INDICATORS | | | 14. GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | 15. PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | 16. CONTROLS REQUIRED FOR SMOKE CONTROL | | | 17. ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1. | | | 18. ELEVATOR EMERGENCY OR STANDBY POWER SELECTOR | | | SWITCH(ES), WHERE EMERGENCY OR STANDBY POWER IS | | | PROVIDED | | | | | | 21. RADIO | | | | | | NFPA 1, CHAPTER 11, BUILDING SERVICES; 11.10 TWO-WAY | | | RADIO ENHANCEMENT SERVICES. | | | 11.10.1 IN ALL NEW AND EXISTING BUILDINGS, MINIMUM | | | RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT | | | COMMUNICATIONS SHALL BE MAINTAINED AT A LEVEL | | | DETERMINED BY THE AHJ. | | | MAINTAIN A MINIMUM RADIO SIGNAL STRENGTH OF 102.0 DBM | | | FOR THE RADIO SYSTEM USED BY WEST PALM BEACH FIRE | | | RESCUE. IF THE MINIMUM CANNOT BE MAINTAINED, A | | | BI-DIRECTIONAL AMPLIFIED SYSTEM SHALL BE INSTALLED WITH | | | A MINIMUM 2-HOUR RUN TIME BATTERY BACK-UP. | | | | | | 22. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 23. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
5 |
Status |
P |
Date |
08-31-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
08-31-2016 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
08-31-2016 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2016-08-31 14:11:49 | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES, TREE GRATES, AND RIGHT OF WAY LANDSCAPING | | | AND IRRIGATION APPROVED WITH THIS PETITION. | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING, TREE GRATES AND IRRIGATION ADJACENT TO | | | THE PROPERTY. THIS WILL BE THROUGH A SEPARATE | | | MAINTENANCE AGREEMENT WITH THE CITY. | | | | | | 4. PRIOR TO THE ISSUANCE OF A LANDSCAPE PERMIT FOR THE | | | SITE, A LANDSCAPE PLAN SHALL BE SUBMITTED FOR THE | | | AMENITY DECK MEETING THE REQUIREMENT OF 27 TREES OR | | | EQUIVALENT PALMS MEETING THE CODE REQUIREMENTS OR AS | | | APPROVED. THE PLANT LIST SHALL BE AMENDED TO INCLUDE | | | THE ADDITIONAL PLANT MATERIAL AND IDENTIFY THE WATER | | | USE CATEGORY FOR ALL PER THE SFWMD WATERWISE GUIDE. AN | | | AMENDMENT TO THE APPROVED PLAN WILL BE REQUIRED TO | | | RECORD THE AMENITY DECK LANDSCAPING AS PART OF THE | | | PLANNING AND ZONING RECORD. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
P |
Date |
07-25-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
07-25-2016 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
07-25-2016 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2016-07-25 14:07:28 | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: 3111 S DIXIE Z15120017 | | | JULY 25, 2016 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. THE PERVIOUS AREA ONLY EXCEEDS THE | | | MINIMUM REQUIRED BY 433 SQUARE FEET. THE STABILIZED | | | EMERGENCY ACCESS AREA IS COUNTED AS 100% PERVIOUS. | | | PLEASE PROVIDE A DETAIL OF THE STABILIZED SYSTEM AND | | | DEDUCT THE AREA THAT IS NOT PERVIOUS. PLEASE BE AWARE | | | THAT ANY CHANGES TO THE DESIGN IN THE FUTURE MUST | | | ACCOUNT FOR ANY PERVIOUS AREA ALTERATIONS, AND ASSURE | | | COMPLIANCE WITH THE MINIMUM REQUIREMENT. | | | | | | 2. SATISFIED. THE WAIVER REQUEST FOR THE DIXIE BUFFER | | | SHOULD INDICATE A 10 FOOT BUFFER IS REQUIRED. PLEASE | | | CORRECT THE CHART ON FSP-1. | | | | | | SECTION 94-443 (D) (1) REQUIRES A 10 FOOT BUFFER ALONG | | | PUBLIC THOROUGHFARES FOR MULTIFAMILY USES, AND A 5 FOOT | | | BUFFER IS REQUIRED FOR COMMERCIAL USES. STAFF CAN | | | SUPPORT THE WAIVER REQUEST TO MODIFY THE BUFFER, AS | | | LONG AS THE DESIGN INCLUDES THE NUMBER OF TREES AS | | | REQUIRED. THE CODE ALLOWS LIMITED CLUSTERING OF BUFFER | | | TREES TO ALLOW FOR INTEGRATION OF SIGNAGE AND FUNCTION. | | | | | | 3. SATISFIED. THE WAIVER REQUEST FOR THE SHADE TREE | | | REDUCTION SHOULD INDICATE THE CORRECT NUMBER OF TREES. | | | LANDSCAPE DATA CHART SHEET LP-1, WAIVER CHART ON FSP-1, | | | AND JUSTIFICATION STATEMENT ARE NOT CONSISTENT WITH THE | | | QUANTITY. | | | | | | SEE RESPONSE TO COMMENT 2. | | | | | | 4. SATISFIED. A LANDSCAPE BUFFER OF 5 FEET IN WIDTH IS | | | SHOWN ON THE PLAN ALONG THE WEST PROPERTY LINE, YET | | | WAIVER REQUEST #6 STILL INDICATES A REQUEST FOR A ZERO | | | BUFFER WIDTH. WAIVER MAY NO LONGER BE NEEDED. THE PALMS | | | MAY BE SUBSTITUTED FOR THE REQUIRED TREES IF THE TOTAL | | | NUMBER OF PALMS SUBSTITUTED FOR SHADE TREES ON SITE | | | DOES NOT EXCEED 35%. | | | | | | 5. SATISFIED. THE CALCULATIONS PROVIDED FOR THE PARKING | | | LOT LANDSCAPE REQUIREMENTS DO NOT REPRESENT AREAS | | | PROVIDED IN THE PARKING AREAS AS REQUIRED. PLEASE | | | REVISE TO SHOW HOW THE LANDSCAPE AREAS WITHIN THE | | | PARKING LOT COMPLY WITH SECTION 94-443(C) 3 AND 4. | | | | | | SOME AREAS DO NOT QUALIFY AS BEING WITHIN THE PARKING | | | AREA, AND OTHER AREAS IN LANDSCAPED MEDIANS ARE NOT | | | COUNTED. | | | | | | 6. CONDITIONALLY SATISFIED. PLEASE PROVIDE A LANDSCAPE | | | PLAN FOR THE ROOFTOP AMENITY DECK. THIS IS MATERIAL IN | | | CONSIDERING THE TRUE QUANTITY OF WAIVER REQUEST #8, AND | | | FOR TREE MITIGATION. | | | | | | A PRELIMINARY PLAN CAN BE SUBMITTED AT THIS TIME FOR | | | APPROVAL, AND AMENDED AT A LATER DATE, OR A CONDITION | | | OF APPROVAL CAN BE ADDED. | | | | | | 7. SATISFIED. WAIVER REQUEST #7 CREATES A NARROW BUFFER | | | AREA AT THE SOUTHWEST CORNER OF THE PROPERTY, AND THE | | | LIVE OAK PROPOSED DOES NOT FIT THE RESTRICTED SPACE | | | BETWEEN THE SIDEWALK AND BUILDING. PLEASE CHANGE TO A | | | MORE APPROPRIATE SPECIES. | | | | | | 8. SATISFIED. THE GUMBO LIMBO TREES PROPOSED ALONG THE | | | NORTH PROPERTY LINE WILL NOT PROVIDE BUFFERING FROM THE | | | ADJACENT USE FOR A SUBSTANTIAL PART OF THE YEAR DUE TO | | | LEAF DROP. PLEASE CONSIDER A MIX OF SPECIES TO PROVIDE | | | MORE DIVERSITY AND YEAR ROUND BUFFERING. | | | | | | 9. PLEASE CORRECT THE TREE DISPOSITION PLAN FOR THE | | | FOLLOWING: | | | ? SATISFIED. TREES TO BE RELOCATED NEED TO BE TAGGED | | | WITH THEIR IDENTIFYING NUMBER, AND LOCATION SHOWN BY | | | NUMBER ON THE PROPOSED LANDSCAPE PLAN | | | ? SATISFIED. PROVIDE THE CATEGORY AND QUANTITY FOR EACH | | | TREE TO BE REPLACED 1:1 AND PROVIDE THE MITIGATION FOR | | | THE TREE CANOPY REPLACEMENT AS A SEPARATE QUANTITY. | | | ? SATISFIED. PROVIDE AN ADDITIONAL COLUMN TO RECORD | | | TREE CANOPY WIDTH 35 FEET OR MORE. | | | | | | 10. SATISFIED. PLEASE PROVIDE A PLAN FOR THE RELOCATION | | | SHOWING HOW TREES TO BE RELOCATED WILL BE STORED OR | | | PLACED PERMANENTLY DURING DEMOLITION AND CONSTRUCTION. | | | THIS NEEDS TO BE ADDRESSED AT A CONCEPTUAL LEVEL PRIOR | | | TO APPROVAL TO ASSURE THAT IT IS POSSIBLE. | | | | | | 11. SATISFIED. STREET TREES LOCATED IN A SIDEWALK SHALL | | | HAVE STRUCTURAL SOIL EXTENDING 5 FEET IN ALL DIRECTIONS | | | FROM THE TREE GRATE AND PLANTING PIT UP TO THE CURB. | | | INDICATE STRUCTURAL SOIL LOCATIONS ON THE LANDSCAPE | | | PLAN AND CORRECT THE TYPICAL STRUCTURAL SOIL DETAIL ON | | | THE LANDSCAPE DETAIL PAGE. | | | | | | 12. SATISFIED. THE TREE GRATES WILL BE U S FOUNDRY 9531 | | | IF NO LIGHTING IS GOING TO BE INSTALLED. PLEASE VERIFY | | | IF 9530 IS TO BE USED THAT LIGHTING WILL BE INSTALLED. | | | | | | A RESPONSE WAS NOT PROVIDED. | | | | | | 13. SATISFIED. THERE ARE LOCATIONS OF LIGHTING ON THE | | | LANDSCAPE PLAN THAT APPEAR TO CONFLICT WITH | | | LANDSCAPING. PLEASE PROVIDE THE HEIGHT OF THE FIXTURES | | | IN THESE AREAS. | | | | | | 14. SATISFIED. PLEASE SHOW LOCATIONS OF ROOT BARRIERS | | | TO PROTECT INFRASTRUCTURE AND TREES FROM CONFLICTS. | | | THIS INCLUDES WATER, SEWER, DRAINAGE, SIDEWALKS AND | | | CURBS, AND ANY FIELD STRUCTURES THAT COULD BE IMPACTED | | | BY TREE ROOTS. | | | | | | 15. SATISFIED. PLEASE SHOW LOCATIONS OF ALL GROUND | | | MOUNTED EQUIPMENT INCLUDING FPL TRANSFORMERS, A/C | | | UNITS, ETC., AND PROVIDE SCREENING FOR ALL GROUND | | | MOUNTED EQUIPMENT AND UTILITIES. THERE ARE STILL SOME | | | AREAS THAT NEED SCREENING. | | | | | | PLEASE UNDERSTAND THAT ADDITIONAL INFORMATION MAY BE | | | REQUESTED, AND STAFF MAY HAVE ADDITIONAL COMMENTS AS | | | THE REVIEW PROCESS CONTINUES. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES, TREE GRATES, AND RIGHT OF WAY LANDSCAPING | | | AND IRRIGATION APPROVED WITH THIS PETITION. | | | | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING, TREE GRATES AND IRRIGATION ADJACENT TO | | | THE PROPERTY. THIS WILL BE THROUGH A SEPARATE | | | MAINTENANCE AGREEMENT WITH THE CITY. | | | | | | 4. 4. PRIOR TO THE ISSUANCE OF A LANDSCAPE PERMIT FOR | | | THE SITE, A LANDSCAPE PLAN SHALL BE SUBMITTED FOR THE | | | AMENITY DECK MEETING THE REQUIREMENT OF 27 TREES OR | | | EQUIVALENT PALMS MEETING THE CODE REQUIREMENTS OR AS | | | APPROVED. AN AMENDMENT TO THE APPROVED PLAN WILL BE | | | REQUIRED TO RECORD THE AMENITY DECK LANDSCAPING AS PART | | | OF THE PLANNING AND ZONING RECORD. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
F |
Date |
06-13-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
06-13-2016 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
06-13-2016 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2016-06-13 17:00:47 | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: 3111 S DIXIE Z15120017 | | | JUNE 9, 2016 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. THE PERVIOUS AREA ONLY EXCEEDS THE | | | MINIMUM REQUIRED BY 433 SQUARE FEET. THE STABILIZED | | | EMERGENCY ACCESS AREA IS COUNTED AS 100% PERVIOUS. | | | PLEASE PROVIDE A DETAIL OF THE STABILIZED SYSTEM AND | | | DEDUCT THE AREA THAT IS NOT PERVIOUS. PLEASE BE AWARE | | | THAT ANY CHANGES TO THE DESIGN IN THE FUTURE MUST | | | ACCOUNT FOR ANY PERVIOUS AREA ALTERATIONS, AND ASSURE | | | COMPLIANCE WITH THE MINIMUM REQUIREMENT. | | | | | | 2. NOT SATISFIED. THE WAIVER REQUEST FOR THE DIXIE | | | BUFFER SHOULD INDICATE A 10 FOOT BUFFER IS REQUIRED. | | | PLEASE CORRECT THE CHART ON FSP-1. | | | | | | SECTION 94-443 (D) (1) REQUIRES A 10 FOOT BUFFER ALONG | | | PUBLIC THOROUGHFARES FOR MULTIFAMILY USES, AND A 5 FOOT | | | BUFFER IS REQUIRED FOR COMMERCIAL USES. STAFF CAN | | | SUPPORT THE WAIVER REQUEST TO MODIFY THE BUFFER, AS | | | LONG AS THE DESIGN INCLUDES THE NUMBER OF TREES AS | | | REQUIRED. THE CODE ALLOWS LIMITED CLUSTERING OF BUFFER | | | TREES TO ALLOW FOR INTEGRATION OF SIGNAGE AND FUNCTION. | | | | | | 3. NOT SATISFIED. THE WAIVER REQUEST FOR THE SHADE TREE | | | REDUCTION SHOULD INDICATE THE CORRECT NUMBER OF TREES. | | | LANDSCAPE DATA CHART SHEET LP-1, WAIVER CHART ON FSP-1, | | | AND JUSTIFICATION STATEMENT ARE NOT CONSISTENT WITH THE | | | QUANTITY. | | | | | | SEE RESPONSE TO COMMENT 2. | | | | | | 4. SATISFIED. A LANDSCAPE BUFFER OF 5 FEET IN WIDTH IS | | | SHOWN ON THE PLAN ALONG THE WEST PROPERTY LINE, YET | | | WAIVER REQUEST #6 STILL INDICATES A REQUEST FOR A ZERO | | | BUFFER WIDTH. WAIVER MAY NO LONGER BE NEEDED. THE PALMS | | | MAY BE SUBSTITUTED FOR THE REQUIRED TREES IF THE TOTAL | | | NUMBER OF PALMS SUBSTITUTED FOR SHADE TREES ON SITE | | | DOES NOT EXCEED 35%. | | | | | | 5. PARTIALLY SATISFIED. THE CALCULATIONS PROVIDED FOR | | | THE PARKING LOT LANDSCAPE REQUIREMENTS DO NOT REPRESENT | | | AREAS PROVIDED IN THE PARKING AREAS AS REQUIRED. PLEASE | | | REVISE TO SHOW HOW THE LANDSCAPE AREAS WITHIN THE | | | PARKING LOT COMPLY WITH SECTION 94-443(C) 3 AND 4. | | | | | | SOME AREAS DO NOT QUALIFY AS BEING WITHIN THE PARKING | | | AREA, AND OTHER AREAS IN LANDSCAPED MEDIANS ARE NOT | | | COUNTED. | | | | | | 6. NOT SATISFIED. PLEASE PROVIDE A LANDSCAPE PLAN FOR | | | THE ROOFTOP AMENITY DECK. THIS IS MATERIAL IN | | | CONSIDERING THE TRUE QUANTITY OF WAIVER REQUEST #8, AND | | | FOR TREE MITIGATION. | | | | | | A PRELIMINARY PLAN CAN BE SUBMITTED AT THIS TIME FOR | | | APPROVAL, AND AMENDED AT A LATER DATE, OR A CONDITION | | | OF APPROVAL CAN BE ADDED. | | | | | | 7. SATISFIED. WAIVER REQUEST #7 CREATES A NARROW BUFFER | | | AREA AT THE SOUTHWEST CORNER OF THE PROPERTY, AND THE | | | LIVE OAK PROPOSED DOES NOT FIT THE RESTRICTED SPACE | | | BETWEEN THE SIDEWALK AND BUILDING. PLEASE CHANGE TO A | | | MORE APPROPRIATE SPECIES. | | | | | | 8. SATISFIED. THE GUMBO LIMBO TREES PROPOSED ALONG THE | | | NORTH PROPERTY LINE WILL NOT PROVIDE BUFFERING FROM THE | | | ADJACENT USE FOR A SUBSTANTIAL PART OF THE YEAR DUE TO | | | LEAF DROP. PLEASE CONSIDER A MIX OF SPECIES TO PROVIDE | | | MORE DIVERSITY AND YEAR ROUND BUFFERING. | | | | | | 9. PLEASE CORRECT THE TREE DISPOSITION PLAN FOR THE | | | FOLLOWING: | | | ? SATISFIED. TREES TO BE RELOCATED NEED TO BE TAGGED | | | WITH THEIR IDENTIFYING NUMBER, AND LOCATION SHOWN BY | | | NUMBER ON THE PROPOSED LANDSCAPE PLAN | | | ? NOT SATISFIED. PROVIDE THE CATEGORY AND QUANTITY FOR | | | EACH TREE TO BE REPLACED 1:1 AND PROVIDE THE MITIGATION | | | FOR THE TREE CANOPY REPLACEMENT AS A SEPARATE QUANTITY. | | | ? NOT SATISFIED. PROVIDE AN ADDITIONAL COLUMN TO RECORD | | | TREE CANOPY WIDTH 35 FEET OR MORE. | | | | | | 10. SATISFIED. PLEASE PROVIDE A PLAN FOR THE RELOCATION | | | SHOWING HOW TREES TO BE RELOCATED WILL BE STORED OR | | | PLACED PERMANENTLY DURING DEMOLITION AND CONSTRUCTION. | | | THIS NEEDS TO BE ADDRESSED AT A CONCEPTUAL LEVEL PRIOR | | | TO APPROVAL TO ASSURE THAT IT IS POSSIBLE. | | | | | | 11. SATISFIED. STREET TREES LOCATED IN A SIDEWALK SHALL | | | HAVE STRUCTURAL SOIL EXTENDING 5 FEET IN ALL DIRECTIONS | | | FROM THE TREE GRATE AND PLANTING PIT UP TO THE CURB. | | | INDICATE STRUCTURAL SOIL LOCATIONS ON THE LANDSCAPE | | | PLAN AND CORRECT THE TYPICAL STRUCTURAL SOIL DETAIL ON | | | THE LANDSCAPE DETAIL PAGE. | | | | | | 12. NOT SATISFIED. THE TREE GRATES WILL BE U S FOUNDRY | | | 9531 IF NO LIGHTING IS GOING TO BE INSTALLED. PLEASE | | | VERIFY IF 9530 IS TO BE USED THAT LIGHTING WILL BE | | | INSTALLED. | | | | | | A RESPONSE WAS NOT PROVIDED. | | | | | | 13. SATISFIED. THERE ARE LOCATIONS OF LIGHTING ON THE | | | LANDSCAPE PLAN THAT APPEAR TO CONFLICT WITH | | | LANDSCAPING. PLEASE PROVIDE THE HEIGHT OF THE FIXTURES | | | IN THESE AREAS. | | | | | | 14. SATISFIED. PLEASE SHOW LOCATIONS OF ROOT BARRIERS | | | TO PROTECT INFRASTRUCTURE AND TREES FROM CONFLICTS. | | | THIS INCLUDES WATER, SEWER, DRAINAGE, SIDEWALKS AND | | | CURBS, AND ANY FIELD STRUCTURES THAT COULD BE IMPACTED | | | BY TREE ROOTS. | | | | | | 15. SATISFIED. PLEASE SHOW LOCATIONS OF ALL GROUND | | | MOUNTED EQUIPMENT INCLUDING FPL TRANSFORMERS, A/C | | | UNITS, ETC., AND PROVIDE SCREENING FOR ALL GROUND | | | MOUNTED EQUIPMENT AND UTILITIES. THERE ARE STILL SOME | | | AREAS THAT NEED SCREENING. | | | | | | PLEASE UNDERSTAND THAT ADDITIONAL INFORMATION MAY BE | | | REQUESTED, AND STAFF MAY HAVE ADDITIONAL COMMENTS AS | | | THE REVIEW PROCESS CONTINUES. | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES, TREE GRATES, AND RIGHT OF WAY LANDSCAPING | | | AND IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING, TREE GRATES AND IRRIGATION ADJACENT TO | | | THE PROPERTY. THIS WILL BE THROUGH A SEPARATE | | | MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
05-10-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
05-10-2016 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
05-10-2016 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2016-05-10 12:16:24 | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: 3111 S DIXIE Z15120017 | | | MAY 9, 2016 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. THE PERVIOUS AREA ONLY EXCEEDS THE MINIMUM REQUIRED | | | BY 433 SQUARE FEET. THE STABILIZED EMERGENCY ACCESS | | | AREA IS COUNTED AS 100% PERVIOUS. PLEASE PROVIDE A | | | DETAIL OF THE STABILIZED SYSTEM AND DEDUCT THE AREA | | | THAT IS NOT PERVIOUS. PLEASE BE AWARE THAT ANY CHANGES | | | TO THE DESIGN IN THE FUTURE MUST ACCOUNT FOR ANY | | | PERVIOUS AREA ALTERATIONS, AND ASSURE COMPLIANCE WITH | | | THE MINIMUM REQUIREMENT. | | | | | | 2. THE WAIVER REQUEST FOR THE DIXIE BUFFER SHOULD | | | INDICATE A 10 FOOT BUFFER IS REQUIRED. PLEASE CORRECT | | | THE CHART ON FSP-1. | | | | | | 3. THE WAIVER REQUEST FOR THE SHADE TREE REDUCTION | | | SHOULD INDICATE THE CORRECT NUMBER OF TREES. LANDSCAPE | | | DATA CHART SHEET LP-1, WAIVER CHART ON FSP-1, AND | | | JUSTIFICATION STATEMENT ARE NOT CONSISTENT WITH THE | | | QUANTITY. | | | | | | 4. A LANDSCAPE BUFFER OF 5 FEET IN WIDTH IS SHOWN ON | | | THE PLAN ALONG THE WEST PROPERTY LINE, YET WAIVER | | | REQUEST #6 STILL INDICATES A REQUEST FOR A ZERO BUFFER | | | WIDTH. WAIVER MAY NO LONGER BE NEEDED. THE PALMS MAY BE | | | SUBSTITUTED FOR THE REQUIRED TREES IF THE TOTAL NUMBER | | | OF PALMS SUBSTITUTED FOR SHADE TREES ON SITE DOES NOT | | | EXCEED 35%. | | | | | | 5. THE CALCULATIONS PROVIDED FOR THE PARKING LOT | | | LANDSCAPE REQUIREMENTS DO NOT REPRESENT AREAS PROVIDED | | | IN THE PARKING AREAS AS REQUIRED. PLEASE REVISE TO SHOW | | | HOW THE LANDSCAPE AREAS WITHIN THE PARKING LOT COMPLY | | | WITH SECTION 94-443(C) 3 AND 4. | | | | | | 6. PLEASE PROVIDE A LANDSCAPE PLAN FOR THE ROOFTOP | | | AMENITY DECK. THIS IS MATERIAL IN CONSIDERING THE TRUE | | | QUANTITY OF WAIVER REQUEST #8, AND FOR TREE MITIGATION. | | | | | | 7. WAIVER REQUEST #7 CREATES A NARROW BUFFER AREA AT | | | THE SOUTHWEST CORNER OF THE PROPERTY, AND THE LIVE OAK | | | PROPOSED DOES NOT FIT THE RESTRICTED SPACE BETWEEN THE | | | SIDEWALK AND BUILDING. PLEASE CHANGE TO A MORE | | | APPROPRIATE SPECIES. | | | | | | 8. THE GUMBO LIMBO TREES PROPOSED ALONG THE NORTH | | | PROPERTY LINE WILL NOT PROVIDE BUFFERING FROM THE | | | ADJACENT USE FOR A SUBSTANTIAL PART OF THE YEAR DUE TO | | | LEAF DROP. PLEASE CONSIDER A MIX OF SPECIES TO PROVIDE | | | MORE DIVERSITY AND YEAR ROUND BUFFERING. | | | | | | 9. PLEASE CORRECT THE TREE DISPOSITION PLAN FOR THE | | | FOLLOWING: | | | ? TREES TO BE RELOCATED NEED TO BE TAGGED WITH THEIR | | | IDENTIFYING NUMBER, AND LOCATION SHOWN BY NUMBER ON THE | | | PROPOSED LANDSCAPE PLAN | | | ? PROVIDE THE CATEGORY AND QUANTITY FOR EACH TREE TO BE | | | REPLACED 1:1 AND PROVIDE THE MITIGATION FOR THE TREE | | | CANOPY REPLACEMENT AS A SEPARATE QUANTITY. | | | ? PROVIDE AN ADDITIONAL COLUMN TO RECORD TREE CANOPY | | | WIDTH 35 FEET OR MORE. | | | | | | 10. PLEASE PROVIDE A PLAN FOR THE RELOCATION SHOWING | | | HOW TREES TO BE RELOCATED WILL BE STORED OR PLACED | | | PERMANENTLY DURING DEMOLITION AND CONSTRUCTION. THIS | | | NEEDS TO BE ADDRESSED AT A CONCEPTUAL LEVEL PRIOR TO | | | APPROVAL TO ASSURE THAT IT IS POSSIBLE. | | | | | | 11. STREET TREES LOCATED IN A SIDEWALK SHALL HAVE | | | STRUCTURAL SOIL EXTENDING 5 FEET IN ALL DIRECTIONS FROM | | | THE TREE GRATE AND PLANTING PIT UP TO THE CURB. | | | INDICATE STRUCTURAL SOIL LOCATIONS ON THE LANDSCAPE | | | PLAN AND CORRECT THE TYPICAL STRUCTURAL SOIL DETAIL ON | | | THE LANDSCAPE DETAIL PAGE. | | | | | | 12. THE TREE GRATES WILL BE U S FOUNDRY 9531 IF NO | | | LIGHTING IS GOING TO BE INSTALLED. PLEASE VERIFY IF | | | 9530 IS TO BE USED THAT LIGHTING WILL BE INSTALLED. | | | | | | 13. THERE ARE LOCATIONS OF LIGHTING ON THE LANDSCAPE | | | PLAN THAT APPEAR TO CONFLICT WITH LANDSCAPING. PLEASE | | | PROVIDE THE HEIGHT OF THE FIXTURES IN THESE AREAS. | | | | | | 14. PLEASE SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT | | | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES | | | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY | | | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 15. PLEASE SHOW LOCATIONS OF ALL GROUND MOUNTED | | | EQUIPMENT INCLUDING FPL TRANSFORMERS, A/C UNITS, ETC., | | | AND PROVIDE SCREENING FOR ALL GROUND MOUNTED EQUIPMENT | | | AND UTILITIES. THERE ARE STILL SOME AREAS THAT NEED | | | SCREENING. | | | | | | PLEASE UNDERSTAND THAT ADDITIONAL INFORMATION MAY BE | | | REQUESTED, AND STAFF MAY HAVE ADDITIONAL COMMENTS AS | | | THE REVIEW PROCESS CONTINUES. | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES, TREE GRATES, RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING, TREE GRATES AND IRRIGATION ADJACENT TO | | | THE PROPERTY. THIS WILL BE THROUGH A SEPARATE | | | MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
01-12-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-12-2016 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-12-2016 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2016-01-12 17:10:20 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: 3111 S DIXIE Z15120017 | | | JANUARY 12, 2016 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PLEASE CORRECT THE OPEN SPACE DIAGRAM ON SHEET OSP1 | | | TO REFLECT THE MAXIMUM IMPERVIOUS AREA AS 80%. | | | | | | 2. PLEASE PROVIDE A LANDSCAPE PLAN FOR THE ROOFTOP | | | AMENITY DECK. | | | | | | 3. PLEASE PROVIDE CALCULATIONS FOR THE BUFFER TREES | | | REQUIRED FOR ALL 4 BUFFER LENGTHS, AND INDICATE HOW | | | MANY WILL BE ELIMINATED THROUGH THE WAIVER REQUESTS. | | | | | | 4. PLEASE PROVIDE A DETAIL OF THE PLANTING SYSTEM ALONG | | | THE WEST FA?ADE, AND INCLUDE A CROSS SECTION SHOWING | | | THE INSTALLATION RELATIVE TO THE PROPERTY LINE. STAFF | | | HAS CONCERNS REGARDING LONG TERM MAINTENANCE OF THIS | | | FEATURE, AND HOW ACCESS WILL BE OBTAINED FROM FEC RIGHT | | | OF WAY. THIS WILL BE USED TO EVALUATE IF THIS AREA | | | QUALIFIES AS FOUNDATION PLANTING AREA. | | | | | | 5. THE DATA PROVIDED ON SHEET LP-1 NEEDS TO BE | | | CLARIFIED TO REFLECT THE NUMBER OF TREES PROVIDED IN | | | THE LANDSCAPE PLAN. THE MITIGATION CHART WILL INCLUDE | | | THE DETAILS OF HOW MANY TREES ARE BEING RELOCATED. | | | | | | 6. PLEASE CORRECT THE TREE DISPOSITION PLAN FOR THE | | | FOLLOWING: | | | ? IDENTIFY TREES 200 THROUGH 204 | | | ? IDENTIFY THE YELLOW TABS AND PINK TABS INDIVIDUALLY. | | | ? TREES TO BE RELOCATED NEED TO BE TAGGED WITH THEIR | | | IDENTIFYING NUMBER, AND LOCATION SHOWN BY NUMBER ON THE | | | PROPOSED LANDSCAPE PLAN | | | ? PROVIDE THE CATEGORY FOR EACH TREE TO BE REMOVED AND | | | REPLACED 1:1 | | | | | | 7. PLEASE PROVIDE A PLAN FOR THE RELOCATION SHOWING HOW | | | TREES TO BE RELOCATED WILL BE STORED OR PLACED | | | PERMANENTLY DURING DEMOLITION AND CONSTRUCTION. | | | | | | 8. PLEASE PROVIDE THE DROUGHT TOLERANCE LEVEL FOR EACH | | | PLANT SPECIES ON THE PLANT LIST CHARTS TO VERIFY | | | PERCENTAGES CLAIMED WITH THE FLORIDA FRIENDLY LANDSCAPE | | | REQUIREMENTS OF SECTION 94-442 (G). | | | | | | 9. STREET TREES LOCATED IN A SIDEWALK SHALL HAVE | | | STRUCTURAL SOIL EXTENDING 5 FEET IN ALL DIRECTIONS UP | | | TO THE CURB. INDICATE STRUCTURAL SOIL LOCATIONS AND | | | PROVIDE A TYPICAL STRUCTURAL SOIL DETAIL ON THE | | | LANDSCAPE DETAIL PAGE. | | | | | | 10. PLEASE ADD A DETAIL FOR THE TREE GRATES. THE TREE | | | GRATES MUST BE U S FOUNDRY 9531. | | | | | | 11. PLEASE PROVIDE DETAILS ON THE JAPANESE BLUEBERRY TO | | | MEET THE DEFINITION OF SHADE TREE PER CODE. MUST REACH | | | A MATURE SIZE OF AT LEAST15 FEET TALL AND PROVIDE A | | | CANOPY OF 15 FEET WIDE. | | | | | | 12. PLEASE PROVIDE THE VARIETY FOR THE LAGERSTROEMIA TO | | | VERIFY THEY WILL MEET THE SHADE TREE REQUIREMENTS. | | | SINGLE TRUNK MAY ALSO BE MORE APPROPRIATE IN SOME | | | INSTANCES. | | | | | | 13. THE JAPANESE BLUEBERRY SIZE SPECIFICATIONS ARE NOT | | | ADEQUATE FOR PLACEMENT AS STREET TREES. THE SIZE MUST | | | BE AT LEAST 14 FEET, AND 6 TO 7 FOOT CLEAR TRUNK TO | | | ALLOW CLEARANCE FOR PEDESTRIAN AND VEHICULAR TRAFFIC. | | | OAKS MAY BE MORE APPROPRIATE FOR STREET TREES. | | | | | | 14. PLEASE PROVIDE LOCATIONS OF LIGHTING ON THE | | | LANDSCAPE PLAN TO AVOID CONFLICTS WITH LANDSCAPING. | | | | | | 15. PLEASE SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT | | | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES | | | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY | | | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 16. PLEASE SHOW LOCATIONS OF ALL GROUND MOUNTED | | | EQUIPMENT INCLUDING FPL TRANSFORMERS, A/C UNITS, ETC., | | | AND PROVIDE SCREENING FOR ALL GROUND MOUNTED EQUIPMENT | | | AND UTILITIES. | | | | | | PLEASE UNDERSTAND THAT ADDITIONAL INFORMATION MAY BE | | | REQUESTED, AND STAFF MAY HAVE ADDITIONAL COMMENTS AS | | | THE REVIEW PROCESS CONTINUES. | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE | | | STREET TREES, TREE GRATES, RIGHT OF WAY LANDSCAPING AND | | | IRRIGATION APPROVED WITH THIS PETITION. | | | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE | | | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF | | | WAY LANDSCAPING, TREE GRATES AND IRRIGATION ADJACENT TO | | | THE PROPERTY. THIS WILL BE THROUGH A SEPARATE | | | MAINTENANCE AGREEMENT WITH THE CITY. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PU |
PUBLIC UTILITIES |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2016-06-10 17:12:26 | THIS IS A PRELIMINARY REVIEW OF THE CONCEPTUAL PLANS | | | RESUBMITTAL DATED MAY 2016. THE FOLLOWING COMMENTS ARE | | | TO BE ADDRESSED PRIOR TO ENGINEERING DEVELOPMENT | | | APPROVAL: | | | | | | 1. RECORD INFORMATION INDICATES THAT THE EXISTING WATER | | | MAIN ON HAMPTON ROAD IS A DEAD END MAIN. THE EXISTING | | | 6-INCH WATER MAIN REDUCES TO A 3-INCH WATER MAIN | | | APPROXIMATELY 340 FEET FROM S. DIXIE HIGHWAY AND | | | TERMINATES AT THE LAST WATER SERVICE JUST EAST OF THE | | | RAILROAD RIGHT-OF-WAY. BOTH WERE INSTALLED IN 1940'S. | | | THE INITIAL CONCEPTUAL PLAN SUBMITTAL DATED APRIL 2016 | | | SHOWED APPROX. 180 LF OF NEW 8-INCH WATER MAIN FROM S. | | | DIXIE HIGHWAY TO SERVE THE PROPOSED DEVELOPMENT. PLEASE | | | EXTEND THE NEW 8-INCH WATER MAIN APPROX. 240 LF BEYOND | | | THE PROPOSED 8-INCH FIRE LINE SERVICE CONNECTION. | | | ABANDON THE EXISTING WATER MAINS AND TRANSFER ALL | | | EXISTING SERVICE CONNECTIONS TO THE NEW WATER MAIN. | | | 2. PLEASE ADD A BACKFLOW DEVICE FOR EACH OF THE | | | PROPOSED WATER SERVICE THAT WILL SERVE A WATER FEATURE; | | | 3. PLEASE NOTE THAT THE CITY IS EVALUATING IMPACTS TO | | | THE WATER AND SEWER SYSTEMS DUE TO INCREASED DEMANDS. | | | | | | LAURA LE, P.E. | | | PUBLIC UTILITIES ENGINEER | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
01-13-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
01-13-2016 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
01-13-2016 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2016-01-13 12:36:26 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
01-13-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
01-13-2016 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
01-13-2016 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2016-01-13 12:35:43 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
01-13-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
01-13-2016 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
01-13-2016 |
Time |
12:34 |
Sent To |
|
|
| Notes |
| 2016-01-13 12:35:16 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
01-13-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
01-13-2016 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
01-13-2016 |
Time |
12:34 |
Sent To |
|
|
| Notes |
| 2016-01-13 12:34:53 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
05-11-2016 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
05-11-2016 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
05-11-2016 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2016-05-11 10:39:45 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 05.11.2016 | | | PROJECT NO.: Z15120015, Z15120016 & Z15120017 | | | CASE NO.: PB 1693, 1693A & 1693B | | | ADDRESS: 3111 SOUTH DIXIE HIGHWAY | | | APPLICANT/CONTACT: CHRISTOPHER BARRY, AICP CUD | | | TELEPHONE NO.: 561.366.1100 | | | SCOPE OF REVIEW: MIXED-USE DEVELOPMENT CONSISTING OF | | | 300 RESIDENTIAL DWELLING UNITS; 13,600 SQUARE FEET OF | | | RETAIL; AND 5,600 SQUARE FEET OF RESTAURANT (INCLUDES | | | OUTDOOR SEATING). | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO ALL OF THE | | | FOLLOWING REVIEW COMMENTS: | | | | | | 1. FOR THE FUTURE LAND USE MAP AMENDMENT: | | | | | | A. A LEVEL OF SERVICE DETERMINATION LETTER SHALL BE | | | PROVIDED FROM THE PALM BEACH COUNTY SCHOOL DISTRICT. | | | | | | ADDITIONAL COMMENTS: THE DETERMINATION LETTER FROM THE | | | SCHOOL DISTRICT INDICATES THAT THE MIDDLE AND HIGH | | | SCHOOL UTILIZATIONS ARE PROJECTED TO EXCEED 100% AND | | | THAT MITIGATION OR SOME OTHER SOLUTIONS MAY BE | | | NECESSARY IN ORDER TO KEEP THE SCHOOL FROM BEING | | | OVERCROWDED. HAS THERE BEEN ANY FOLLOW UP WITH THE | | | SCHOOL DISTRICT ON THIS MATTER? A RESOLUTION WILL NEED | | | TO BE IN PLACE PRIOR TO PUBLIC HEARING. | | | | | | B. A LEVEL OF SERVICE ANALYSIS SHALL BE PROVIDED FOR | | | PUBLIC PARKS. | | | | | | ADDITIONAL COMMENTS: THIS ANALYSIS STILL NEEDS TO BE | | | PROVIDED. | | | | | | C. WRITTEN CONFIRMATION SHALL BE PROVIDED FROM THE | | | VARIOUS SERVICE AGENCIES INDICATING THAT SUFFICIENT | | | CAPACITY EXISTS TO ACCOMMODATE THE INCREASE IN DEMAND | | | RESULTING FROM INCREASE IN DEMAND GENERATED BY THE | | | BUILD-OUT OF THE PROPOSED FLU DESIGNATION. | | | | | | ADDITIONAL COMMENTS: THIS DOCUMENTATION STILL NEEDS TO | | | BE PROVIDED. | | | | | | 4. THE LETTER FROM COMCAST INDICATES AN AERIAL VIEW | | | THAT WAS ATTACHED; PLEASE PROVIDE SUCH. | | | | | | ADDITIONAL COMMENTS: I DID NOT SEE A COPY OF THIS | | | LETTER/AERIAL IN THE RESUBMITTAL. | | | | | | 6. PLEASE EXPLAIN THE ACREAGE DISCREPANCY CHART | | | PROVIDED IN EXHIBIT C OF THE JUSTIFICATION STATEMENT. | | | | | | ADDITIONAL COMMENTS: NO EXPLANATION HAS BEEN PROVIDED. | | | | | | 7. TRAFFIC CONCURRENCY APPROVAL SHALL BE PROVIDED FROM | | | PALM BEACH COUNTY. | | | | | | ADDITIONAL COMMENTS: CONCURRENCY APPROVAL STILL HAS | | | NOT BEEN PROVIDED. | | | | | | 10. VERIFY THAT ALL IMPROVEMENTS COMPLY WITH THE | | | VISIBILITY REQUIREMENTS OF THE FDOT. IT SEEMS THAT SOME | | | OF THE ON-STREET PARKING AT THE SOUTH END OF THE | | | PROJECT WOULD CREATE SIGNIFICANT VISIBILITY CONCERNS. | | | | | | ADDITIONAL COMMENTS: HAS ANY PRELIMINARY APPROVAL BEEN | | | ISSUED BY FDOT? APPROVAL NEEDS TO BE PROVIDED FOR ALL | | | IMPROVEMENTS PROPOSED WITHIN THE SOUTH DIXIE | | | RIGHT-OF-WAY. THERE IS SOME CONCERN THAT SOME | | | IMPROVEMENTS MAY BE WITHIN THE REQUIRED SITE DISTANCE | | | AT THE INTERSECTIONS/DRIVEWAYS (I.E. BUS SHELTER, | | | ON-STREET PARKING, SIGNAGE, ETC.). | | | | | | 13. PLEASE PROVIDE DOCUMENTATION FROM THE FDOT | | | INDICATING THAT THEY HAVE NO OBJECTION TO THE PROPOSED | | | DRIVEWAY CONFIGURATION, SEPARATION OF ACCESS POINTS, | | | ON-STREET PARKING, ETC. | | | | | | ADDITIONAL COMMENTS: SEE COMMENT #10. | | | | | | 15. PLEASE PROVIDE THE PHOTOMETRIC LEVELS FOR ALL PARTS | | | OF THE PROPERTY AT THE PROPERTY LINE. PURSUANT TO SEC. | | | 94-207(D)(8), ILLUMINATION SHALL NOT EXCEED 1.0 | | | FOOTCANDLES AT THE OR BEYOND THE BOUNDARY OF THE | | | DEVELOPMENT. | | | | | | ADDITIONAL COMMENTS: PHOTOMETRIC LEVELS WERE NOT | | | PROVIDED AT THE PROPERTY LINE. | | | | | | 16. IT IS ENCOURAGED THAT A LIST OF PERMITTED USES BE | | | DEVELOPED SO AS TO ENSURE THAT FUTURE TENANTS COMPLY | | | WITH THE VISION AND UNDERSTANDING OF THE TYPE OF | | | PROJECT THAT IS BEING PROPOSED. IF NO LIST OF PERMITTED | | | USES IS PROVIDED, THE CPD WILL REVERT TO THE PERMITTED | | | USE TABLE FOR THE GENERAL COMMERCIAL (GC) ZONING | | | DISTRICT. | | | | | | ADDITIONAL COMMENTS: SOME MODIFICATIONS TO THE | | | PROPOSED PERMITTED USE LIST MAY BE NECESSARY ? ADDITION | | | OF RESIDENTIAL, MULTIFAMILY; REMOVAL OF PARKING LOTS AS | | | PRINCIPAL, ACCESSORY OR OFF-SITE USES; REMOVAL OF | | | RESIDENTIAL SINGLE-FAMILY ATTACHED AND DETACHED. | | | | | | 17. ADDITIONAL BICYCLE PARKING SHALL BE PROVIDED | | | ADJACENT TO EACH RESIDENTIAL TOWER TO ACCOUNT FOR | | | VISITORS. | | | | | | ADDITIONAL COMMENTS: BIKE RACKS SHOULD BE PLACED IN | | | CLOSE PROXIMITY / VISIBLE TO THE NON-RESIDENTIAL USES | | | ALONG SOUTH DIXIE HIGHWAY AND AT THE ENTRANCES TO THE | | | RESIDENTIAL TOWERS, UNLESS THERE IS A WAY TO DIRECT | | | GUESTS AND MAKE THEM AWARE OF THE RACKS IN THE GARAGE. | | | | | | 20. THERE IS INCONSISTENCY BETWEEN THE SETBACK | | | MEASUREMENTS OF THE RESIDENTIAL BUILDINGS. FOR EXAMPLE, | | | SOME ARE MEASURED FROM DIXIE HIGHWAY TO THE EDGE OF THE | | | BALCONY LINE, OTHERS ARE MEASURED TO THE CORER OF THE | | | TOWER. PLEASE BE CONSISTENT. | | | | | | ADDITIONAL COMMENTS: PLEASE NOTE THAT THE NORTHERNMOST | | | RESIDENTIAL TOWER DOES NOT MEET THE 81 FOOT SETBACK. AS | | | DISCUSSED PREVIOUSLY, PART OF YOUR JUSTIFICATION WAS | | | THAT WHILE A WAIVER WAS BEING REQUESTED FOR SETBACKS, | | | THE NEED FOR THE WAIVER WAS BECAUSE OF THE | | | PODIUM/PARKING GARAGE AND THAT ALL OF THE RESIDENTIAL | | | TOWERS COMPLIED WITH SETBACKS (IF MEASURED | | | INDEPENDENTLY OF THE PARKING GARAGE). AS CURRENTLY | | | PROPOSED, THE PLANS DO NOT SUPPORT THIS JUSTIFICATION. | | | EITHER AMEND THE JUSTIFICATION FOR THE WAIVER, OR | | | MODIFY THE SETBACKS FOR THE NORTH TOWER. | | | | | | 25. MORE DETAIL NEEDS TO BE PROVIDED REGARDING THE | | | ARCHITECTURAL TREATMENT OF THE FACADES OF THE BUILDING, | | | ESPECIALLY THE PARKING GARAGE. | | | | | | ADDITIONAL COMMENTS: MY BIGGEST CONCERN IS THAT | | | PORTION OF THE GARAGE THAT FACES HAMPTON ROAD. | | | | | | 26. PLEASE PROVIDE THE SETBACK DIMENSIONS FOR ALL OF | | | THE COMMERCIAL STRUCTURES FROM THE DIXIE HIGHWAY | | | PROPERTY LINE. THE SITE DATA TABLE INDICATES THAT 5 | | | FEET IS BEING PROVIDED, BUT THE ONLY DIMENSION PROVIDED | | | INDICATES THAT THERE IS A 10 FOOT SETBACK. | | | | | | ADDITIONAL COMMENTS: ARE ALL OF THE COMMERCIAL | | | BUILDINGS 8.5 FEET FROM THE RIGHT-OF-WAY? A DIMENSION | | | LINE WAS ONLY PROVIDE FOR THE NORTHERNMOST BUILDING; | | | PLEASE PROVIDE SETBACK DIMENSIONS FOR EACH BUILDING. | | | | | | 27. IT APPEARS THAT THE PROPOSED RESIDENTIAL MONUMENT | | | SIGN WILL IMPEDE WITH THE VISIBILITY ONTO SOUTH DIXIE | | | HIGHWAY. | | | | | | ADDITIONAL COMMENTS: PLEASE SEE COMMENT #10. NOTE THAT | | | AT THE MAIN ENTRANCE THE VISIBILITY TRIANGLE SHOULD BE | | | PROVIDED ON THE NORTH AND SOUTH SIDES OF THE OUTBOUND | | | LANES; IMPROVEMENTS (I.E. PLANTINGS, SIGNAGE, ETC.) IN | | | THE MEDIAN BETWEEN THE INBOUND AND OUTBOUND LANES | | | SHOULD NOT ENCROACH INTO THE VISIBILITY TRIANGLE. | | | | | | 28. HAS ANY DOCUMENTATION BEEN RECEIVED FROM THE FAA | | | INDICATING THAT THERE IS NO OBJECTION TO THE PROPOSED | | | BUILDING HEIGHT? | | | | | | ADDITIONAL COMMENTS: DOCUMENTATION STILL NEEDS TO BE | | | PROVIDED. | | | | | | 32. MORE AESTHETIC DESIGN CONSIDERATION NEEDS TO BE | | | MADE FOR THE DUMPSTER ENCLOSURES, ETC. | | | | | | ADDITIONAL COMMENTS: PLEASE NOTE THAT IT APPEARS THAT | | | THE PROPOSED 10 FOOT WIDE GATE OPENING DOES NOT MEET | | | THE CITY?S MINIMUM STANDARD. PLEASE ADJUST ACCORDINGLY | | | OR OBTAIN APPROVAL FROM THE CITY?S PUBLIC WORKS | | | DEPARTMENT. | | | | | | 36. PLEASE PROVIDE DETAILS AS TO HOW THE GATE SYSTEM IS | | | PROPOSED TO WORK WITH THE PARKING GARAGE. ARE GUESTS | | | PERMITTED IN THE GARAGE? HOW TO THEY GAIN ACCESS? IS | | | THERE A CALL BOX? WHAT HAPPENS IF SOMEONE IS DENIED | | | ACCESS AT THE GATE? | | | | | | ADDITIONAL COMMENTS: SOME FURTHER EXPLANATION NEEDS TO | | | BE PROVIDED ON HOW THE GATES WILL OPERATE WITHOUT | | | IMPEDING THE PARKING SPACES, DRIVE AISLES, ETC. | | | | | | 42. BIKE RACKS SHOULD BE DISTRIBUTED THROUGHOUT THE | | | PROJECT TO PROVIDE ACCESSIBILITY TO VISITORS, | | | RESIDENTS, EMPLOYEES, ETC. AT EACH OF THE BUILDINGS. | | | | | | ADDITIONAL COMMENTS: SEE COMMENT #17. | | | | | | 45. PLEASE PROVIDE A CROSS-SECTION OF THE SOUTH DIXIE | | | HIGHWAY COMMERCIAL FRONTAGE, SPECIFICALLY THAT AREA | | | BETWEEN THE CURB LINE AND THE COMMERCIAL BUILDINGS. | | | STAFF WANTS TO ENSURE THAT SUFFICIENT SIDEWALK WIDTH IS | | | PROVIDED FOR PEDESTRIAN CIRCULATION ON THE COMMERCIAL | | | CORRIDOR. | | | | | | 46. THE PARKING SPOT AT THE FAR SOUTHEAST CORNER OF THE | | | COMMERCIAL PARKING LOT NEEDS TO BE REMOVED AS VEHICLES | | | BACKING OUT OF THIS SPACE WILL ENCROACH INTO THE | | | SIDEWALK, TRAFFIC WILL BE FORCED TO STACK IN THE | | | RIGHT-OF-WAY, ETC. | | | | | | GENERAL CONCERNS OR AREAS IN NEED OF FURTHER | | | DISCUSSION: | | | | | | 4. PROPOSED BUILDING HEIGHTS. | | | | | | ADDITIONAL COMMENTS: AS DISCUSSED PREVIOUSLY, THIS | | | ITEM WILL LIKELY BE AN ON-GOING TOPIC OF DISCUSSION. | | | | | | 9. GLAZING OF THE COMMERCIAL BUILDINGS ON SOUTH DIXIE | | | HIGHWAY. STAFF WANTS TO DISCUSS WAYS TO ENSURE THAT THE | | | SOUTH DIXIE FRONTAGE CONSISTS OF THE MAXIMUM AMOUNT OF | | | CLEAR GLAZING AND THAT IT DOES NOT BECOME A BLANK | | | FRONTAGE WITH TINTED OR SPANDREL GLASS, BACK-OF-HOUSE | | | OF THE INTERIOR USES, OR OTHERWISE BLOCKED FROM THE | | | INSIDE. | | | | | | 10. ON-GOING DISCUSSION NEEDS TO OCCUR REGARDING | | | POTENTIAL PHASING OF THE PROJECT AND HOW ELEMENTS OF | | | THE SITE AND BUILDINGS WILL BE TREATED BETWEEN PHASES, | | | WHAT WILL BE REQUIRED AS PART OF EACH PHASE, ETC. | | | ___________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | F) IN ORDER TO BE CONSIDERED FOR THE JULY 19, 2016 | | | PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE | | | SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED | | | DOCUMENTS/PLANS NO LATER THAN MAY 27, 2016. | | | | | | G) TO BE PLACED ON THE JULY 19, 2016 PLANNING BOARD | | | AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO LATER | | | THAN JULY 4, 2016. SIGNAGE SHALL CONFORM AND BE | | | INSTALLED WITH THE REQUIREMENTS OF THE CITY?S ZONING | | | AND LAND DEVELOPMENT REGULATIONS, AS ALSO PROVIDED IN | | | THE DEVELOPMENT APPLICATION. A SIGNED AND NOTARIZED | | | AFFIDAVIT SHALL BE PROVIDED BY THE DEADLINE REFERENCED | | | ABOVE. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
01-13-2016 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
01-13-2016 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
01-13-2016 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2016-01-13 12:30:23 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 01.13.2016 | | | PROJECT NO.: Z15120015, Z15120016 & Z15120017 | | | CASE NO.: PB 1693, 1693A & 1693B | | | ADDRESS: 3111 SOUTH DIXIE HIGHWAY | | | APPLICANT/CONTACT: CHRISTOPHER BARRY, AICP CUD | | | TELEPHONE NO.: 561.366.1100 | | | SCOPE OF REVIEW: MIXED-USE DEVELOPMENT CONSISTING OF | | | 300 RESIDENTIAL DWELLING UNITS; 14,400 SQUARE FEET OF | | | RETAIL; AND 4,400 SQUARE FEET OF RESTAURANT. | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO ALL OF THE | | | FOLLOWING REVIEW COMMENTS: | | | | | | 1. FOR THE FUTURE LAND USE MAP AMENDMENT: | | | | | | A. A LEVEL OF SERVICE DETERMINATION LETTER SHALL BE | | | PROVIDED FROM THE PALM BEACH COUNTY SCHOOL DISTRICT. | | | | | | B. A LEVEL OF SERVICE ANALYSIS SHALL BE PROVIDED FOR | | | PUBLIC PARKS. | | | | | | C. WRITTEN CONFIRMATION SHALL BE PROVIDED FROM THE | | | VARIOUS SERVICE AGENCIES INDICATING THAT SUFFICIENT | | | CAPACITY EXISTS TO ACCOMMODATE THE INCREASE IN DEMAND | | | RESULTING FROM INCREASE IN DEMAND GENERATED BY THE | | | BUILD-OUT OF THE PROPOSED FLU DESIGNATION. | | | | | | 2. SURVEYS AND SEPARATE LEGAL DESCRIPTIONS WILL NEED TO | | | BE PROVIDED FOR EACH OF THE FOLLOWING: | | | | | | A. THE 6.02 ACRES BEING CHANGED FROM COMMERCIAL (C) TO | | | COMMERCIAL EAST (CE); | | | | | | B. THE 0.99 ACRES BEING CHANGED FROM NEIGHBORHOOD | | | COMMERCIAL (NC) TO GENERAL COMMERCIAL (GC); AND | | | | | | C. THE 8.33 ACRES BEING CHANGED FROM OFFICE COMMERCIAL | | | (OC) TO GENERAL COMMERCIAL (GC). | | | | | | 3. TABLE 3 OF THE FUTURE LAND USE TRAFFIC ANALYSIS | | | INCORRECTLY IDENTIFIES BOTH SCENARIOS AS ?PROPOSED | | | FUTURE LAND USE DEVELOPMENT?. THE FIRST SCENARIO SHOULD | | | BE ?EXISTING FUTURE LAND USE DEVELOPMENT?. | | | | | | 4. THE LETTER FROM COMCAST INDICATES AN AERIAL VIEW | | | THAT WAS ATTACHED; PLEASE PROVIDE SUCH. | | | | | | 5. PAGES 26 AND 31 OF THE JUSTIFICATION STATEMENT | | | INDICATES THAT 18,500 SQUARE FEET OF RETAIL SPACE IS | | | BEING PROVIDED; THE PLANS INDICATES 18,800 SQUARE FEET | | | OF RETAIL/RESTAURANT. PLEASE ENSURE ALL DOCUMENTS | | | MATCH. | | | | | | 6. PLEASE EXPLAIN THE ACREAGE DISCREPANCY CHART | | | PROVIDED IN EXHIBIT C OF THE JUSTIFICATION STATEMENT. | | | | | | 7. TRAFFIC CONCURRENCY APPROVAL SHALL BE PROVIDED FROM | | | PALM BEACH COUNTY. | | | | | | 8. PLEASE PROVIDE PROFESSIONAL CERTIFICATION INDICATING | | | THAT TWO (2) OR MORE OF THE FOLLOWING PROFESSIONALS | | | WERE UTILIZED: | | | | | | A. URBAN PLANNER (AICP) | | | | | | B. LANDSCAPE ARCHITECT (ASLA) | | | | | | C. CIVIL ENGINEER (LICENSED BY STATE OF FLORIDA) | | | | | | D. ARCHITECT (LICENSED BY STATE OF FLORIDA) | | | | | | 9. WAS A MARKET STUDY DONE AS PART OF THIS PROJECT? | | | | | | 10. VERIFY THAT ALL IMPROVEMENTS COMPLY WITH THE | | | VISIBILITY REQUIREMENTS OF THE FDOT. IT SEEM THAT SOME | | | OF THE ON-STREET PARKING AT THE SOUTH END OF THE | | | PROJECT WOULD CREATE SIGNIFICANT VISIBILITY CONCERNS. | | | | | | 11. SHOULD THE END SPOTS OF THE ON-STREET PARKING JUST | | | NORTH OF HAMPTON ROAD HAVE ANGLED CURBING? | | | | | | 12. PLEASE PROVIDE DOCUMENTATION FROM PALM TRAN | | | INDICATING THAT THEY HAVE NO OBJECTION WITH THE | | | PROPOSED LOCATION/DESIGN OF THE BUS STOP (FUTURE | | | SHELTER). | | | | | | 13. PLEASE PROVIDE DOCUMENTATION FROM THE FDOT | | | INDICATING THAT THEY HAVE NO OBJECTION TO THE PROPOSED | | | DRIVEWAY CONFIGURATION, SEPARATION OF ACCESS POINTS, | | | ON-STREET PARKING, ETC. | | | | | | 14. TO PROVIDE BETTER CLARITY WITH REGARD TO THE | | | ARCHITECTURE, PLEASE PROVIDE THE COLOR ELEVATIONS AND | | | RENDERINGS. | | | | | | 15. PLEASE PROVIDE THE PHOTOMETRIC LEVELS FOR ALL PARTS | | | OF THE PROPERTY AT THE PROPERTY LINE. PURSUANT TO SEC. | | | 94-207(D)(8), ILLUMINATION SHALL NOT EXCEED 1.0 | | | FOOTCANDLES AT THE OR BEYOND THE BOUNDARY OF THE | | | DEVELOPMENT. | | | | | | 16. IT IS ENCOURAGED THAT A LIST OF PERMITTED USES BE | | | DEVELOPED SO AS TO ENSURE THAT FUTURE TENANTS COMPLY | | | WITH THE VISION AND UNDERSTANDING OF THE TYPE OF | | | PROJECT THAT IS BEING PROPOSED. IF NO LIST OF PERMITTED | | | USES IS PROVIDED, THE CPD WILL REVERT TO THE PERMITTED | | | USE TABLE FOR THE GENERAL COMMERCIAL (GC) ZONING | | | DISTRICT. | | | | | | 17. ADDITIONAL BICYCLE PARKING SHALL BE PROVIDED | | | ADJACENT TO EACH RESIDENTIAL TOWER TO ACCOUNT FOR | | | VISITORS. | | | | | | 18. LANDSCAPE SCREENING SHALL BE PROVIDED FOR ALL | | | UTILITY CONNECTION, BACKFLOW PREVENTERS, METERS, ETC. | | | IT APPEARS THAT MANY OF THESE COMPONENTS ARE PLACED IN | | | THE MIDDLE OF (CONCRETE?) OPEN PLAZAS. | | | | | | 19. PLANS NEED TO PROVIDE BETTER DEFINITION BETWEEN THE | | | VARIOUS HARDSCAPE MATERIALS. IS THE ENTIRE ?COURTYARD | | | PLAZA AREA? CONCRETE? | | | | | | 20. THERE IS INCONSISTENCY BETWEEN THE SETBACK | | | MEASUREMENTS OF THE RESIDENTIAL BUILDINGS. FOR EXAMPLE, | | | SOME ARE MEASURED FROM DIXIE HIGHWAY TO THE EDGE OF THE | | | BALCONY LINE, OTHERS ARE MEASURED TO THE CORER OF THE | | | TOWER. PLEASE BE CONSISTENT. | | | | | | 21. THE SITE DATA TABLE INDICATES THAT THE RESIDENTIAL | | | SETBACK FROM DIXIE HIGHWAY IS 135.8 FEET; NEITHER OF | | | THE DIMENSIONS ON THE SITE PLAN SHOW THAT DISTANCE. | | | | | | 22. AS THE PARKING GARAGE AND THE RESIDENTIAL TOWERS | | | ARE ALL CONSIDERED ONE (1) STRUCTURE (AS THEY ARE | | | CONNECTED AND FULLY INTEGRATED), THE REQUIRED SETBACKS | | | FOR EVERYTHING IS BASED UPON THE 170 FOOT HEIGHT OF THE | | | TOWERS. FOR EXAMPLE, THE REQUIRED SETBACK FOR THE NORTH | | | PROPERTY IS 81 FEET FOR BOTH THE TOWER AND THE PARKING | | | GARAGE. | | | | | | 23. IN THE SITE DATA TABLE, LIST THE REQUIRED REAR | | | SETBACK AS FIVE (5) FEET, AND MOVE THE ** TO THE | | | DIMENSION LISTED UNDER ?PROPOSED?. | | | | | | 24. PLEASE PROVIDE DETAILS AS TO HOW FENCING, ETC. WILL | | | BE INCORPORATED INTO THE AMENITY DECK TO ADDRESS THE | | | TENNIS COURTS, ENCLOSURE OF THE POOLS, ETC. ARE THE | | | PLANS CORRECT IN THAT THEY SHOW AN 11 FOOT HIGH GLASS | | | PANEL AROUND THE ENTIRE PERIMETER OF THE AMENITY DECK? | | | | | | 25. MORE DETAIL NEEDS TO BE PROVIDED REGARDING THE | | | ARCHITECTURAL TREATMENT OF THE FACADES OF THE BUILDING, | | | ESPECIALLY THE PARKING GARAGE. | | | | | | 26. PLEASE PROVIDE THE SETBACK DIMENSIONS FOR ALL OF | | | THE COMMERCIAL STRUCTURES FROM THE DIXIE HIGHWAY | | | PROPERTY LINE. THE SITE DATA TABLE INDICATES THAT 5 | | | FEET IS BEING PROVIDED, BUT THE ONLY DIMENSION PROVIDED | | | INDICATES THAT THERE IS A 10 FOOT SETBACK. | | | | | | 27. IT APPEARS THAT THE PROPOSED RESIDENTIAL MONUMENT | | | SIGN WILL IMPEDE WITH THE VISIBILITY ONTO SOUTH DIXIE | | | HIGHWAY. | | | | | | 28. HAS ANY DOCUMENTATION BEEN RECEIVED FROM THE FAA | | | INDICATING THAT THERE IS NO OBJECTION TO THE PROPOSED | | | BUILDING HEIGHT? | | | | | | 29. NEED TO ADDRESS THE SERVICE AREA AT THE SOUTHWEST | | | CORNER OF THE PARKING GARAGE. WOULD LIKE TO MINIMIZE | | | THIS AREA TO ALLOW FOR THE MAXIMUM AMOUNT OF | | | LANDSCAPING ALONG THE FA?ADE OF THE BUILDING, MINIMIZE | | | THE IMPACT ON THE PEDESTRIAN ENVIRONMENT ALONG HAMPTON | | | ROAD, ETC. | | | | | | 30. PLEASE NOTE THE ANGLE OF THE PARKING SPACES | | | PROVIDED WEST OF THE COMMERCIAL BUILDINGS. | | | | | | 31. THE ROW OF PARKING IN THE NORTHEASTERN CORNER OF | | | THE COMMERCIAL PARKING AREA IS MISLABELED AS HAVING 10 | | | SPACES, WHEN ONLY 9 ARE PROVIDED. | | | | | | 32. MORE AESTHETIC DESIGN CONSIDERATION NEEDS TO BE | | | MADE FOR THE DUMPSTER ENCLOSURES, ETC. | | | | | | 33. THE OUTDOOR SEATING AREA SHOWN NEAR THE NORTH END | | | OF THE PROPERTY (ALONG DIXIE HIGHWAY) NEEDS TO BE | | | FACTORED INTO THE PARKING CALCULATION. | | | | | | 34. PLEASE PROVIDE AN EXPLANATION OF HOW COMMERCIAL | | | DELIVERIES ARE ANTICIPATED TO OCCUR TO EACH OF THE | | | RETAIL/RESTAURANT BUILDINGS. ONLY ONE LOADING SPACE IS | | | PROVIDED AT THE FAR NORTH END OF THE PROPERTY, AND ANY | | | DELIVERY TRUCK THAT PARKS IN THE DRIVE AISLE OF THE | | | PARKING LOT WILL COMPLETELY BLOCK TRAFFIC FLOW. | | | | | | 35. THE SITE DATA TABLE INDICATES THAT 5 ACCESSIBLE | | | SPACES ARE PROVIDED FOR THE COMMERCIAL BUILDINGS, BUT | | | THE PLANS INDICATE 6. | | | | | | 36. PLEASE PROVIDE DETAILS AS TO HOW THE GATE SYSTEM IS | | | PROPOSED TO WORK WITH THE PARKING GARAGE. ARE GUESTS | | | PERMITTED IN THE GARAGE? HOW TO THEY GAIN ACCESS? IS | | | THERE A CALL BOX? WHAT HAPPENS IF SOMEONE IS DENIED | | | ACCESS AT THE GATE? | | | | | | 37. TURNAROUND SPACES WILL NEED TO BE PROVIDED AT THE | | | EASTERN END OF EACH ROW OF PARKING THAT OCCURS WITHIN | | | THE RESIDENTIAL TOWER. | | | | | | 38. PLEASE DIMENSION THE PARKING, DRIVE AISLES, ETC. | | | FOR THE PARKING GARAGE (ALL LEVELS). | | | | | | 39. THE PARKING COUNT FOR THE GARAGE DOES NOT SEEM TO | | | MATCH THE NUMBER OF SPACES DRAWN; PLEASE CONFIRM. | | | | | | 40. THERE ARE NUMEROUS DIFFERENCES BETWEEN SHEETS FSP-1 | | | AND SP-1. PLEASE ENSURE THAT ALL PLANS ARE CONSISTENT. | | | SP-1 SHOWS A LOT MORE OUTDOOR DINING AREA, DIFFERENT | | | CONFIGURATIONS FOR THE PLANTERS, ETC. | | | | | | 41. THE NUMBER OF BICYCLE PARKING SPACES SHOULD BE | | | DETERMINED BY THE OVERALL PARKING COUNT PROVIDED | | | (COMMERCIAL AND RESIDENTIAL). THE SITE DATA TABLE ONLY | | | ACCOUNTS FOR THE COMMERCIAL PARKING. | | | | | | 42. BIKE RACKS SHOULD BE DISTRIBUTED THROUGHOUT THE | | | PROJECT TO PROVIDE ACCESSIBILITY TO VISITORS, | | | RESIDENTS, EMPLOYEES, ETC. AT EACH OF THE BUILDINGS. | | | | | | 43. PLEASE PROVIDE DETAILS REGARDING THE GREENSCREEN | | | THAT IS PROPOSED ALONG THE WEST FACADE OF THE PARKING | | | GARAGE. | | | | | | 44. HOW DOES A PEDESTRIAN ACCESS THE RESIDENTIAL | | | PORTION OF THE PROJECT FROM DIXIE HIGHWAY IF THE | | | PEDESTRIAN GATES ARE CLOSED? PLEASE MAKE NOTE OF THE | | | REQUIRED ACCESSIBLE ROUTES THAT ARE NECESSARY | | | THROUGHOUT THE PROJECT, INCLUDING FROM THE PUBLIC | | | RIGHT-OF-WAY, BUS STOP, ETC. | | | | | | BELOW ARE COMMENTS PROVIDED BY ALEX HANSEN, SENIOR | | | TRANSPORTATION PLANNER: | | | | | | 1. THE TRIP DISTRIBUTION OF 47% NORTH AND 53% SOUTH | | | SEEMS TO BE COUNTER INTUITIVE. I DON'T SEE WHY MOST OF | | | THE TRIPS WOULD BE GOING SOUTH CONSIDERING THAT BOTH | | | DOWNTOWN AND I-95 (THROUGH BELVEDERE) ARE ACCESSIBLE TO | | | THE NORTH OF THE PROJECT. | | | | | | 2. THE ANALYSIS IS SHOWING THAT OVER 1,070 DAILY TRIPS | | | ARE USING HAMPTON ROAD TO ENTER OR EXIT THE PROJECT. | | | HAMPTON IS A SMALL ROAD WITH AN UNSIGNALIZED | | | INTERSECTION WITH DIXIE WHICH ALSO HAS SOME VISIBILITY | | | ISSUES DUE TO THE PLACEMENT OF A DENTAL OFFICE ON THE | | | SOUTH SIDE OF THE INTERSECTION. I AM CONCERNED THAT | | | THIS INTERSECTION (AND HAMPTON IN GENERAL) MAY BE | | | OVERBURDENED AS A RESULT OF THIS PROJECT. INSTALLING A | | | TRAFFIC LIGHT AT DIXIE AND HAMPTON IS NOT AN OPTION | | | GIVEN THAT THERE IS AN EXISTING LIGHT AT ALBEMARLE AND | | | DIXIE ABOUT 300 FEET TO THE NORTH OF HAMPTON. | | | | | | 3. THE STUDY CLAIMS THAT THE PERCENTAGE OF PEAK HOUR | | | TRIPS FOR THIS PROJECT WILL BE LESS THAN 7.5% OF THE | | | TOTAL DAILY TRIPS. THIS PERCENT OF PEAK HOUR TRIPS IS | | | QUITE LOW FOR A PROJECT WHICH IS PRIMARILY RESIDENTIAL | | | IN NATURE. | | | | | | GENERAL CONCERNS OR AREAS IN NEED OF FURTHER | | | DISCUSSION: | | | | | | 1. INTERCONNECTIVITY BETWEEN THE VARIOUS PARKING AREAS | | | (NORTH AND SOUTH). PLEASE MAKE NOTE OF SEC. | | | 94-313(2)(C). | | | | | | 2. LINING OF THE TOWERS ON THE GROUND FLOOR WITH AN | | | ACTIVE USE THAT FRONTS ONTO THE PARK SPACE. | | | | | | 3. DESIGN OF THE PARK SPACE SO THAT IT IS INTEGRATED | | | WITH BOTH THE RESIDENTIAL AND NON-RESIDENTIAL | | | COMPONENTS OF THE PROJECT. | | | | | | 4. PROPOSED BUILDING HEIGHTS. | | | | | | 5. DESIGN OF THE PARK SPACE DOES NOT LEND ITSELF TO | | | INTEGRATION WITH THE RESIDENTIAL COMPONENTS OF THE | | | PROJECT (TALL FENCE AND HEDGE, ETC.). THERE ARE | | | MULTIPLE SCHOOLS OF THOUGHT THAT CAN BE DISCUSSED | | | REGARDING THIS INTERCONNECTIVITY AND HOW IT ALSO | | | AFFECTS THE SAFETY AND POLICING OF THE SPACE. | | | | | | 6. PLACEMENT OF FENCING. | | | | | | 7. DESIGN OF THE PLAZA AREA BETWEEN AND AROUDN THE | | | COMMERCIAL BUILDINGS. | | | | | | 8. HAS THERE BEEN ANY CONVERSATION REGARDING FUTURE | | | INSTALLATION OF WIRELESS TELECOMMUNICATIONS FACILITIES | | | ON THE TOP OF THE RESIDENTIAL TOWERS? IF SO, I WOULD | | | LIKE TO ADDRESS THE ARCHITECTURAL TREATMENT OF THESE | | | ELEMENTS. | | | ___________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | F) IN ORDER TO BE CONSIDERED FOR THE FEBRUARY 17, 2016 | | | PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE | | | SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED | | | DOCUMENTS/PLANS NO LATER THAN FRIDAY, JANUARY 22, 2016. | | | | | | G) TO BE PLACED ON THE FEBRUARY 17, 2016 PLANNING BOARD | | | AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO LATER | | | THAN FEBRUARY 2, 2016. SIGNAGE SHALL CONFORM AND BE | | | INSTALLED WITH THE REQUIREMENTS OF THE CITY?S ZONING | | | AND LAND DEVELOPMENT REGULATIONS, AS ALSO PROVIDED IN | | | THE DEVELOPMENT APPLICATION. A SIGNED AND NOTARIZED | | | AFFIDAVIT SHALL BE PROVIDED BY THE DEADLINE REFERENCED | | | ABOVE. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| |