Plan Review Details - Project Z15120008
| Plan Review Stops For Project Z15120008 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
01-12-2016 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
01-12-2016 |
Time |
19:03 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
01-12-2016 |
Time |
19:03 |
Sent To |
|
|
| Notes |
| 2016-01-12 19:08:51 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL | | | SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS | | | WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND | | | OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA | | | BUILDING CODE | | | | | | 3. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH | | | ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND | | | OPENING PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 OF | | | THE FLORIDA BUILDING CODE SHALL BE VERIFIED. | | | | | | 4. THE ADDITION TO THE EXISTING BUILDING IS COVERED BY | | | CHAPTER 10 OF THE FLORIDA EXISTING BUILDING CODE. THE | | | HEIGHT AND/OR AREA INCREASE DUE TO THE PROPOSED | | | ADDITION SHALL NOT INCREASE THE TOTAL BUILDING HEIGHT | | | AND/OR AREA BEYOND THAT ALLOWED UNDER THE APPLICABLE | | | PROVISIONS OF CHAPTER 5 OF THE FLORIDA BUILDING CODE | | | FOR THE TYPE OF CONSTRUCTION USED. | | | | | | 5. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | | | 2016-01-12 08:21:50 | SEE ENG PPRC COMMENTS |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
03-14-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-14-2016 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-14-2016 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2016-03-14 13:44:01 | PLANS HAVE BEEN REVISED TO INCLUDE AN OIL/WATER | | | SEPARATOR FOR WASH WATER. | | | | | | WATER AND SEWER PROVIDED BY PALM BEACH COUNTY. | | | | | | SANITATION SHOULD BE PROVIDED BY CITY UNLESS 8 CY OR | | | LARGER CONTAINERS/COMPACTORS ARE UTILIZED. PER SECTION | | | 74-31 OF THE CODE OF ORDINANCES, EVERY COMMERCIAL | | | ESTABLISHMENT WITHIN THE CITY SHALL SUBSCRIBE FOR | | | REGULAR COMMERCIAL SOLID WASTE COLLECTION AND DISPOSAL | | | SERVICES FROM THE CITY EXCEPT THOSE COMMERCIAL | | | ESTABLISHMENTS FOR WHICH THE CITY IS UNABLE TO PROVIDE | | | THE NEEDED SERVICES, E.G., CONTAINERS AND COMPACTORS | | | OVER EIGHT CUBIC YARDS. FOR THESE SERVICES, THE | | | COMMERCIAL ESTABLISHMENT MUST USE THE SERVICES OF A | | | PROVIDER APPROVED TO OPERATE WITHIN THE CITY PURSUANT | | | TO A FRANCHISE AGREEMENT. NO PERSON SHALL ATTEMPT TO | | | USE CITY SERVICES WITHOUT HAVING FIRST SUBSCRIBED FOR | | | SUCH SERVICES OR WITHOUT HAVING REQUESTED THE CITY TO | | | PERFORM A SPECIAL SOLID WASTE COLLECTION AND DISPOSAL. | | | | | | | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
01-12-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
01-12-2016 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
01-12-2016 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2016-01-12 08:20:48 | CITY OF WEST PALM BEACH | | | PUBLIC WORKS DEPARTMENT | | | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | BUILDING PERMIT APPLICATION PROCESSES. | | | 1. WILL THE WASH WATER BE RECYCLED? THE WATER CANNOT BE | | | DIRECTED TO THE SANITY SYSTEM WITHOUT THE INSTALLATION | | | OF AN INTERCEPTOR (ORDINANCE 90-125). WASH WATER MAY | | | NOT BE DIRECTED TO THE STORMWATER SYSTEM. PREFERABLY, | | | THE WASH WATER SHOULD BE COLLECTED IN A WASH PIT AND | | | DISPOSED OF BY AN INDUSTRIAL WASTE COMPANY. | | | 2. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE | | | AVAILABLE AT HTTP://WWW.CO.PALM-BEACH.FL.US/NEWSROOM/08 | | | 14/08-26-14-FLOOD_MAPS.HTM. PLEASE REVIEW THE MAPS AND | | | VERIFY THAT THE NEW MAPS WILL NOT IMPACT THE PROPOSED | | | PROJECT. | | | 3. PLEASE PROVIDE AN AUTOTURN ANALYSIS DEMONSTRATING | | | THE SOLID WASTE COLLECTION VEHICLE CAN ACCESS THE | | | PROPOSED DUMPSTER AND COMPACTOR LOCATIONS. THE TRASH | | | DUMPSTER/COMPACTORS MUST LOCATED IN AREAS EASILY | | | SERVICED BY THE CITY SANITATION EQUIPMENT AND MANPOWER | | | PER SECTION 74-35(A)(5) OF THE CODE OF ORDINANCES. IF A | | | ROLL-OFF COMPACTOR IS PROPOSED, PLEASE PROVIDE A LETTER | | | FROM THE PRIVATE PROVIDER VERIFYING THAT THEY CAN | | | PROVIDE SERVICE WITH THE CONFIGURATION SHOWN ON THE | | | PLANS. | | | 4. PLEASE REVISE THE LANDSCAPE PLAN TO SHOW LOCATIONS | | | OF ALL WATER METERS, VALVES, CLEAN-OUTS, LIGHT POLES, | | | ETC. ROOT BARRIERS MAY BE REQUIRED WHERE PLANTINGS ARE | | | NEAR UNDERGROUND STORMWATER, SANITARY, OR POTABLE WATER | | | LINES. | | | 5. REMOVE THE PARKING SPACE AT THE CAR WASH EXIT. | | | 6. SUBMIT UPDATED STORMWATER MANAGEMENT CALCULATIONS | | | INDICATING THE PROJECTS MEETS THE C-51 DRAINAGE BASIN | | | REQUIREMENTS. DRAINAGE DESIGN CALCULATIONS MUST | | | DEMONSTRATE WATER QUALITY TREATMENT AND STORM | | | ATTENUATION ARE PROVIDED ON-SITE. (ORDINANCE 4303-10) | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING DIVISION OF THE PUBLIC | | | WORKS DEPARTMENT. THE ENGINEERING DEVELOPMENT APPROVAL | | | APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | | | | KELLY CRANFORD, P.E. | | | PUBLIC WORKS CIP MANAGER | | | [email protected] | | | 561-494-1098 (OFFICE) | | | | | | VINCE NOEL, PSM | | | CITY SURVEYOR / REAL ESTATE SUPERVISOR | | | [email protected] | | | 561-494-1096 | | | | | | BRIAN COLLINS, PE | | | CITY TRAFFIC ENGINEER | | | [email protected] | | | 561-494-1040 | | | | | | FERDINAND RIVERA | | | PUBLIC WORKS OPERATIONS MANAGER | | | [email protected] | | | 561-822-2076 | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
12-31-2015 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
12-31-2015 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
12-31-2015 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2015-12-31 15:06:31 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESSES SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDINGS SHALL COMPLY WITH | | | THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. ALL GATES SHALL BE EQUIPPED WITH A KNOX KEY SWITCH | | | SYSTEM OR KNOX PADLOCK FOR 24 HOUR FIRE RESCUE | | | EMERGENCY ACCESS. | | | | | | 7. FIRE HYDRANTS LOCATIONS WERE NOT EASILY | | | IDENTIFIABLE. STRONG CONSIDERATION SHALL BE GIVEN TO | | | PROVIDING A WATER SUPPLY/FIRE HYDRANT THROUGHOUT THE | | | VEHICLE STORAGE AREA FOR EMERGECY WATER NEEDS. | | | | | | 8. A FDC WAS INDICATED ON THE SITE PLAN, PLEASE PROVIDE | | | INFORMATION AS TO WHAT THIS FDC SUPPLIES. A FIRE | | | HYDRANT WAS NOT INDICATED IN THE SAME AREA. A FIRE | | | HYDRANT SHALL BE LOCATED WITHIN 150 FT OF A FDC. | | | | | | 9. ALL PARKING LOT ACCESS AND EGRESS POINTS SHALL HAVE | | | A MINIMUM FOR 20FT WIDE AND 13'5" HEIGTH CLEARANCE FOR | | | FIRE APPARATUS. | | | | | | 10. PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED | | | FOR STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR ANY | | | MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE | | | WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED | | | WITH A MALTESE CROSS SIGN MEASURING 8 INCHES | | | HORIZONTALLY AND 8 INCHES VERTICALLY, OF A BRIGHT RED | | | REFLECTIVE COLOR. THE APPROVED SYMBOL SHALL BE PLACED | | | WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY DOOR. | | | A. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER "R". | | | B. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER "F". | | | C. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | 11. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 12. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
03-04-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
03-04-2016 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
03-04-2016 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2016-03-04 15:51:16 | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: NAPLETON Z15120008 AND Z15120007 | | | MARCH 4, 2016 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PLEASE PROVIDE THE PERCENTAGE OF PALMS | | | SUBSTITUTED FOR REQUIRED TREES ON SITE, CODE ALLOWS UP | | | TO 35%. | | | | | | 2. SATISFIED. A SHADE TREE IS REQUIRED IN THE TERMINAL | | | LANDSCAPE ISLAND ADJACENT TO THE MODIFIED ADA SPACES AT | | | THE NORTHEAST CORNER OF THE BUILDING. | | | | | | 3. SATISFIED. PLEASE INDICATE HOW THE FOUR EXISTING | | | TREES IN CLOSE PROXIMITY TO THE PROPOSED CAR WASH WILL | | | BE PROTECTED DURING CONSTRUCTION. | | | | | | 4. SATISFIED. PLEASE SUBMIT A COPY OF THE PALM BEACH | | | COUNTY APPROVED LANDSCAPE PLAN. | | | | | | 5. SATISFIED. PLEASE SHOW ALL UTILITIES INCLUDING FPL, | | | WATER, SEWER, AND DRAINAGE ON THE LANDSCAPE PLAN THAT | | | MAY BE PRESENT IN THE AREAS OF MODIFICATION. PLEASE | | | PROVIDE SCREENING FOR ALL GROUND MOUNTED EQUIPMENT AND | | | UTILITIES. | | | | | | 6. SATISFIED. PLEASE PROVIDE A ROOT BARRIER DETAIL AND | | | SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT | | | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES | | | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY | | | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 7. SATISFIED. PLEASE PROVIDE LANDSCAPING AND SCREENING | | | FOR ALL GROUND MOUNTED EQUIPMENT INCLUDING FPL, WATER | | | AND PHONE/ CABLE, GENERATORS, A/C UNITS ETC. | | | | | | 8. SATISFIED. PLEASE CONSIDER SUBSTITUTING A DIFFERENT | | | SPECIES FOR THE ONE LAUREL OAK PROPOSED. THE MAJORITY | | | OF LAUREL OAKS ON SITE ARE DOING VERY POORLY, AND THE | | | ONES LOCATED ALONG THE OKEECHOBEE LANDSCAPE BUFFER ARE | | | BEING MAINTAINED IN AN UNHEALTHY MANNER. THIS IS AN | | | OPPORTUNITY TO MAKE CHANGES TO A MORE APPROPRIATE | | | SPECIES THAT WILL FIT THE SPACE BETTER AND MEET THE | | | NEEDS OF THE BUSINESS FOR VISIBILITY. | | | | | | 9. SATISFIED. IF ANY TREES ARE TO BE REMOVED OR | | | RELOCATED, A TREE ALTERATION PERMIT IS REQUIRED. | | | | | | ADDITIONAL COMMENTS 2/19: | | | 10. SATISFIED. THE SITE EXCEEDS THE NUMBER OF SHADE | | | TREES REQUIRED, BUT DOES NOT SHOW THE CALCULATIONS FOR | | | REQUIRED FLOWERING TREES. THE NUMBER OF PALMS | | | SUBSTITUTED FOR REQUIRED TREES IS LIMITED TO 35% BY | | | QUANTITY, NOT BY BUFFERS. THEREFORE IF THE APPLICANT | | | WOULD LIKE TO CHANGE MORE OF THE TREES ALONG OKEECHOBEE | | | TO ROYAL PALMS, THE 35% SHOULD MAKE THIS POSSIBLE. | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
02-22-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
02-22-2016 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
02-22-2016 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2016-02-22 15:15:44 | | | | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: NAPLETON Z15120008 AND Z15120007 | | | FEBRUARY 19, 2016 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PLEASE PROVIDE THE PERCENTAGE OF PALMS | | | SUBSTITUTED FOR REQUIRED TREES ON SITE, CODE ALLOWS UP | | | TO 35%. | | | | | | 2. SATISFIED. A SHADE TREE IS REQUIRED IN THE TERMINAL | | | LANDSCAPE ISLAND ADJACENT TO THE MODIFIED ADA SPACES AT | | | THE NORTHEAST CORNER OF THE BUILDING. | | | | | | 3. SATISFIED. PLEASE INDICATE HOW THE FOUR EXISTING | | | TREES IN CLOSE PROXIMITY TO THE PROPOSED CAR WASH WILL | | | BE PROTECTED DURING CONSTRUCTION. | | | | | | 4. SATISFIED. PLEASE SUBMIT A COPY OF THE PALM BEACH | | | COUNTY APPROVED LANDSCAPE PLAN. | | | | | | 5. SATISFIED. PLEASE SHOW ALL UTILITIES INCLUDING FPL, | | | WATER, SEWER, AND DRAINAGE ON THE LANDSCAPE PLAN THAT | | | MAY BE PRESENT IN THE AREAS OF MODIFICATION. PLEASE | | | PROVIDE SCREENING FOR ALL GROUND MOUNTED EQUIPMENT AND | | | UTILITIES. | | | | | | 6. SATISFIED. PLEASE PROVIDE A ROOT BARRIER DETAIL AND | | | SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT | | | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES | | | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY | | | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 7. SATISFIED. PLEASE PROVIDE LANDSCAPING AND SCREENING | | | FOR ALL GROUND MOUNTED EQUIPMENT INCLUDING FPL, WATER | | | AND PHONE/ CABLE, GENERATORS, A/C UNITS ETC. | | | | | | 8. SATISFIED. PLEASE CONSIDER SUBSTITUTING A DIFFERENT | | | SPECIES FOR THE ONE LAUREL OAK PROPOSED. THE MAJORITY | | | OF LAUREL OAKS ON SITE ARE DOING VERY POORLY, AND THE | | | ONES LOCATED ALONG THE OKEECHOBEE LANDSCAPE BUFFER ARE | | | BEING MAINTAINED IN AN UNHEALTHY MANNER. THIS IS AN | | | OPPORTUNITY TO MAKE CHANGES TO A MORE APPROPRIATE | | | SPECIES THAT WILL FIT THE SPACE BETTER AND MEET THE | | | NEEDS OF THE BUSINESS FOR VISIBILITY. | | | | | | 9. SATISFIED. IF ANY TREES ARE TO BE REMOVED OR | | | RELOCATED, A TREE ALTERATION PERMIT IS REQUIRED. | | | | | | ADDITIONAL COMMENTS 2/19: | | | 10. THE SITE EXCEEDS THE NUMBER OF SHADE TREES | | | REQUIRED, BUT DOES NOT SHOW THE CALCULATIONS FOR | | | REQUIRED FLOWERING TREES. THE NUMBER OF PALMS | | | SUBSTITUTED FOR REQUIRED TREES IS LIMITED TO 35% BY | | | QUANTITY, NOT BY BUFFERS. THEREFORE IF THE APPLICANT | | | WOULD LIKE TO CHANGE MORE OF THE TREES ALONG OKEECHOBEE | | | TO ROYAL PALMS, THE 35% SHOULD MAKE THIS POSSIBLE. | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
01-08-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
01-08-2016 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
01-08-2016 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2016-01-08 16:37:09 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 | | | PROJECT: NAPLETON Z15120008 | | | JANUARY 8, 2016 | | | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PLEASE PROVIDE THE PERCENTAGE OF PALMS SUBSTITUTED | | | FOR REQUIRED TREES ON SITE, CODE ALLOWS UP TO 35%. | | | | | | 2. A SHADE TREE IS REQUIRED IN THE TERMINAL LANDSCAPE | | | ISLAND ADJACENT TO THE MODIFIED ADA SPACES AT THE | | | NORTHEAST CORNER OF THE BUILDING. | | | | | | 3. PLEASE INDICATE HOW THE FOUR EXISTING TREES IN CLOSE | | | PROXIMITY TO THE PROPOSED CAR WASH WILL BE PROTECTED | | | DURING CONSTRUCTION. | | | | | | 4. PLEASE SUBMIT A COPY OF THE PALM BEACH COUNTY | | | APPROVED LANDSCAPE PLAN. | | | | | | 5. PLEASE SHOW ALL UTILITIES INCLUDING FPL, WATER, | | | SEWER, AND DRAINAGE ON THE LANDSCAPE PLAN THAT MAY BE | | | PRESENT IN THE AREAS OF MODIFICATION. PLEASE PROVIDE | | | SCREENING FOR ALL GROUND MOUNTED EQUIPMENT AND | | | UTILITIES. | | | | | | 6. PLEASE PROVIDE A ROOT BARRIER DETAIL AND SHOW | | | LOCATIONS OF ROOT BARRIERS TO PROTECT INFRASTRUCTURE | | | AND TREES FROM CONFLICTS. THIS INCLUDES WATER, SEWER, | | | DRAINAGE, SIDEWALKS AND CURBS, AND ANY FIELD STRUCTURES | | | THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 7. PLEASE PROVIDE LANDSCAPING AND SCREENING FOR ALL | | | GROUND MOUNTED EQUIPMENT INCLUDING FPL, WATER AND | | | PHONE/ CABLE, GENERATORS, A/C UNITS ETC. | | | | | | 8. PLEASE CONSIDER SUBSTITUTING A DIFFERENT SPECIES FOR | | | THE ONE LAUREL OAK PROPOSED. THE MAJORITY OF LAUREL | | | OAKS ON SITE ARE DOING VERY POORLY, AND THE ONES | | | LOCATED ALONG THE OKEECHOBEE LANDSCAPE BUFFER ARE BEING | | | MAINTAINED IN AN UNHEALTHY MANNER. THIS IS AN | | | OPPORTUNITY TO MAKE CHANGES TO A MORE APPROPRIATE | | | SPECIES THAT WILL FIT THE SPACE BETTER AND MEET THE | | | NEEDS OF THE BUSINESS FOR VISIBILITY. | | | | | | 9. IF ANY TREES ARE TO BE REMOVED OR RELOCATED, A TREE | | | ALTERATION PERMIT IS REQUIRED. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
03-14-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-14-2016 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-14-2016 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
01-12-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
01-12-2016 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
01-12-2016 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2016-01-12 08:22:16 | SEE ENG PPRC COMMENTS |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
P |
Date |
03-14-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-14-2016 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-14-2016 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
01-12-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
01-12-2016 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
01-12-2016 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
P |
Date |
01-12-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
01-12-2016 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
01-12-2016 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
P |
Date |
03-14-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-14-2016 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-14-2016 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
01-12-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
01-12-2016 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
01-12-2016 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2016-01-12 08:21:16 | SEE ENG PPRC COMMENTS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
02-26-2016 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
02-26-2016 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2016-02-26 17:25:40 | PLANNING AND ZONING COMMENT: | | | | | | 2/26/16 | | | | | | SITE PLAN HAS BEEN APPROVED WITH THE FOLLOWING | | | CONDITION: | | | | | | 1. IF THE PROPOSED EASEMENT ALONG THE EAST SIDE OF THE | | | PROPERTY IS PUT IN PLACE PRIOR TO PERMITTING, THEN, AN | | | EASEMENT CONSENT FORM WILL NEED TO BE SUBMITTED WITH | | | BUILDING PERMITS GRANTING APPROVAL FROM THE EASEMENT | | | HOLDER TO HAVE IMPROVEMENTS (PARKING, LANDSCAPING, | | | ETC.) IN THE EASEMENT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
01-12-2016 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
01-12-2016 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
01-11-2016 |
Time |
17:35 |
Sent To |
|
|
| Notes |
| 2016-01-12 17:39:12 | PLANNING AND ZONING COMMENTS: | | | | | | 1/12/16 | | | | | | 1. SUBMIT ORIGINAL SIGNED OWNER'S AFFIDAVIT, ONLY A | | | COPY WAS PROVIDED IN THE APPLICATIONS. | | | | | | 2. SUBMIT ALL UTILITY LETTERS. | | | | | | 3. PLEASE ADDRESS THE FOLLOWING ON THE PHOTOMETRIC | | | PLAN: | | | | | | A. INCLUDE A NOTATION THAT THE PLAN COMPLIES WITH ZLDR | | | SEC. 94-309(A) REGARDING GLARE ON ADJACENT | | | THOROUGHFARES. | | | | | | B. INCLUDE SETBACKS ON THE PLAN. ALL NEW LIGHT POLES | | | MUST COMPLY WITH BUILDING SETBACKS. | | | | | | 4. CORRECT STRIPING DETAIL TO SHOW ALL DOUBLE STRIPED | | | LINES FOR ALL SPACES AND CONNECTED AT THE BOTTOM. | | | PLEASE CONTACT ME IF YOU NEED A COPY OF THE STANDARD | | | STRIPING DETAIL. | | | | | | 5. THE BICYCLE RACK MODEL LISTED ON THE PLAN IS NOT | | | CONSISTENT IN STYLE OF RACK SHOWN ON THE PLAN. PLEASE | | | NOTE THE BICYCLE RACK MODEL NVBR LISTED ON THE PLANS IS | | | A COMB STYLE RACK AND IS NOT A PERMITTED STYLE. PLEASE | | | REVISE. | | | | | | 6. PLEASE LOCATE TWO BICYCLE RACKS CLOSER TO THE MAIN | | | BUILDING ENTRANCE. THE OTHER TWO RACKS ARE FINE IN THE | | | ORIGINAL LOCATION PROPOSED. ADJUST DETAILS ACCORDINGLY. | | | | | | 7. THE FOLLOWING ARE COMMENTS ON THE SITE DATA CHART ON | | | SHEET SP1: | | | | | | A. THE PROVIDED OPEN SPACE SHOULD BE CLOSER TO 93% AND | | | SHOULD BE RE-REVIEWED. PLEASE NOTE THAT OPEN SPACE | | | MEANS "AN OPEN, UNENCLOSED AREA CONSISTING OF SETBACKS, | | | LANDSCAPING, BUFFERS, VEHICULAR AND PEDESTRIAN | | | CIRCULATION FEATURES, AND SURFACE PARKING." | | | | | | B. FOR THE BUILDING COVERAGE CALCULATION, IT APPEARS | | | THAT THE SQUARE FOOTAGE FOR THE SECOND FLOOR OF | | | BUILDING #1 HAS BEEN INCLUDED AND SHOULD NOT BE COUNTED | | | TOWARD BUILDING COVERAGE. THE SQUARE FOOTAGE FOR | | | BUILDING #2 AND #3 DO NOT MATCH THEIR BUILDING | | | FOOTPRINTS ON THE PLAN. PLEASE REVISE OR EXPLAIN THIS | | | DISCREPANCY. ADJUST ALL BUILDING COVERAGE NUMBERS | | | ACCORDINGLY. | | | | | | C. FOR THE PARKING CALCULATION, IT APPEARS THE AREA FOR | | | THE SERVICE BAYS AND CAR WASH ARE BEING CALCULATED | | | TWICE INTO THE PARKING CALCULATION - ONCE FOR THE MOTOR | | | VEHICLE SALES & SERVICE AND A SECOND TIME UNDER SERVICE | | | BAYS OR CAR WASH, RESPECTIVELY. PLEASE DO NOT COUNT THE | | | SQUARE FOOTAGE OF THE SERVICE BAYS AND CAR WASH INTO | | | THE MOTOR VEHICLE SALES & SERVICE PARKING AS THEY ARE | | | ALREADY PROVIDING REQUIRED PARKING UNDER THEIR | | | RESPECTIVE CATEGORIES. PLEASE UPDATE THE PARKING | | | COUNTS. | | | | | | D. PLEASE CLARIFY ON THE PLANS IF THE TOTAL PROPOSED | | | SPACES INCLUDE ONLY REGULAR SPACES OR REGULAR SPACES | | | AND ADA SPACES. | | | | | | 8. REVISE DUMPSTER DETAIL TO MEET MINIMUM DIMENSIONS OF | | | ZLDR SEC. 94-444, FIGURE XIV-3. | | | | | | 9. IF ANY CHANGES TO THE SITE DATA AFFECT THE | | | JUSTIFICATION STATEMENT, PLEASE UPDATE THE | | | JUSTIFICATION STATEMENT TO REFLECT THE CHANGES. | | | | | | 10. WHEN RESUBMITTING: | | | | | | A. PROVIDE WRITTEN RESPONSES TO REVIEW COMMENTS MADE BY | | | DEPARTMENTS IN A WRITTEN FORMAT WHEN RESUBMITTING. | | | | | | B. PROVIDE 12 SETS OF REVISED PLANS AND/OR DOCUMENTS | | | ALONG WITH ONE REDUCED COPY AND ELECTRONIC COPY OF ALL | | | PLANS. | | | | | | C. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | D. PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | E. IN ORDER TO BE CONSIDERED FOR THE MARCH 3, 2016 | | | ZONING BOARD OF APPEALS MEETING, ALL PLANS MUST BE | | | REVISED AND SUBMITTED BY MONDAY, FEBRUARY 8, 2016. | | | | | | [NOTE: ONE SET OF COMMENTS HAS BEEN POSTED ADDRESSING | | | BOTH ZBA 3334 AND ISPR 15-07.] | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | | |
|
|
| |
Print |
|