Plan Review Details - Project Z15110007
| Plan Review Stops For Project Z15110007 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
12-17-2015 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
12-17-2015 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
12-17-2015 |
Time |
18:28 |
Sent To |
|
|
| Notes |
| 2015-12-17 18:45:32 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. ON SHEET SP-2, THERE ARE 27 PARKING SPACES PROPOSED, | | | SO 2 ACCESSIBLE PARKING SPACES ARE REQUIRED. THE | | | MINIMUM NUMBER OF ACCESSIBLE PARKING SPACES PROVIDED | | | SHALL BE IN ACCORDANCE WITH SECTION 208.2 OF FLORIDA | | | ACCESSIBILITY CODE. | | | | | | 3. EACH OF THE ACCESSIBLE PARKING SPACES MUST BE | | | LOCATED SO THAT IT IS THE CLOSEST PARKING SPACE TO THE | | | ACCESSIBLE MAIN ENTRANCE OF THE PROPOSED EXPANSION | | | BUILDING AND THE EXISTING BUILDING. PER SECTION 208.3 | | | OF FLORIDA ACCESSIBILITY CODE, ACCESSIBLE PARKING | | | SPACES ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE | | | OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE | | | ENTRANCE FOR EACH BUILDING. THE DESIGN OF ACCESSIBLE | | | PARKING SPACES SHALL COMPLY WITH SECTION 502 OF FLORIDA | | | ACCESSIBILITY CODE. | | | | | | 4. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 5. EACH SEPARATE BUILDING SHALL HAVE A SEPARATE | | | ADDRESS. FOR STREET ADDRESSING, CONTACT MICHAEL ORIO, | | | GIS SUPPORT SPECIALIST, AT (561) 494 1080, OR BY EMAIL: | | | [email protected] | | | | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
03-14-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-14-2016 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-14-2016 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2016-03-14 10:52:08 | PREVIOUS COMMENTS HAVE NOT BEEN ADDRESSED. |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
12-07-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
12-07-2015 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
12-07-2015 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2015-12-07 11:42:55 | CITY OF WEST PALM BEACH | | | PUBLIC WORKS DEPARTMENT | | | | | | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL. | | | | | | 1. PLEASE SUBMIT ESTIMATES FOR THE INCREASE IN PEAK | | | POTABLE WATER DEMAND, SANITARY SEWER FLOW, AND SOLID | | | WASTE COLLECTION YARDAGE. | | | | | | 2. PLEASE REVISE THE DRIVEWAY APRONS TO MEET THE CITY?S | | | ENGINEERING DESIGN STANDARDS. HTTP://WPB.ORG/ENGINEERIN | | | G/ENGINEERING-SERVICES/ENGINEERING-STANDARDS/ | | | | | | 3. PLEASE REVISE PLANS TO INCLUDE THE CITY OF WEST PALM | | | BEACH GARBAGE RECEPTACLE DETAIL. MINIMUM DIMENSIONAL | | | REQUIREMENTS ARE LISTED IN SECTION 94-444(B) OF THE | | | CODE OF ORDINANCES. CITY STANDARD DETAIL GC-8 MAY BE | | | DOWNLOADED AT HTTP://WPB.ORG/ENGINEERING/ENGINEERING-SE | | | RVICES/ENGINEERING-STANDARDS/ | | | | | | 4. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE | | | AVAILABLE AT HTTP://WWW.CO.PALM-BEACH.FL.US/NEWSROOM/08 | | | 14/08-26-14-FLOOD_MAPS.HTM. PLEASE REVIEW THE MAPS AND | | | VERIFY THAT THE NEW MAPS WILL NOT IMPACT THE PROPOSED | | | PROJECT. | | | | | | 5. PRELIMINARY ENGINEERING PLANS (WATER, SEWER, PAVING, | | | AND DRAINAGE) WERE NOT SUBMITTED. WATER, SEWER, AND | | | DRAINAGE CONNECTION LOCATIONS ARE NOT APPROVED. | | | | | | 6. THE EXISTING SITE HAS EXISTING DIMENSIONAL | | | NON-CONFORMANCES (SECTION 94-513 OF THE CODE OF | | | ORDINANCES), SOME OF WHICH WERE AUTHORIZED BY SPECIAL | | | EXCEPTION #1350 ISSUED IN 1967. | | | | | | A. EXISTING DRIVEWAYS OFF OF WINDSOR ARE SEPARATED BY | | | 55 FEET, WHICH IS LESS THAN THE MINIMUM SEPARATION (125 | | | FT) REQUIRED BY CODE SECTION 94-313. | | | | | | B. TURN AROUND SPACES ARE NOT PROVIDED AT EITHER OF THE | | | EXISTING DEAD-END DRIVE AISLES (CODE SECTION 94-485). | | | | | | C. EXISTING SOUTHERN ENTRANCE IS 35 FEET FROM THE | | | INTERSECTION, RATHER THAN THE REQUIRED 50 FEET. (CODE | | | SECTION 94-313) | | | | | | D. NONRESIDENTIAL USES WITH LESS THAN 300 REQUIRED | | | PARKING SPACES ARE PERMITTED ONE ACCESS POINT ONTO EACH | | | RIGHT-OF-WAY. THIS SITE CURRENTLY HAS TWO ACCESS POINTS | | | OFF OF WINDSOR. (CODE SECTION 94-313) | | | | | | E. SIDEWALK WIDTH ALONG WINDSOR IS FOUR FEET INSTEAD OF | | | THE CITY STANDARD WIDTH OF FIVE FEET. | | | | | | 7. THE EXISTING CURB CUT ON WINDSOR AT THE ALLEY | | | ENTRANCE MUST BE REMOVED AND THE SIDEWALK AND | | | CURB/GUTTER CONSTRUCTED TO MATCH THE REMAINDER OF | | | WINDSOR ROAD. | | | | | | 8. PLEASE EXPLAIN WHY THE SITE PLAN SHOWS A PORTION OF | | | THE ALLEY OUTSIDE OF THIS PARCEL AS ?ABANDONED ALLEY?. | | | | | | 9. PLEASE DEMONSTRATE THAT THE PROJECT WILL PROVIDE | | | ADEQUATE DRAINAGE AND STORMWATER MANAGEMENT. COMPLIANCE | | | WITH CHAPTER 40E-4 WILL DEMONSTRATE COMPLIANCE WITH | | | THIS PROVISION [SECTIONS 90-201, 94-35(C )(11), AND | | | 94-307]. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL | | | BE REQUIRED FROM THE ENGINEERING DIVISION OF THE PUBLIC | | | WORKS DEPARTMENT. THE ENGINEERING DEVELOPMENT APPROVAL | | | APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 2. A UNITY OF TITLE APPLICATION WILL BE REQUIRED FROM | | | THE ENGINEERING DIVISION OF THE PUBLIC WORKS | | | DEPARTMENT. THE APPLICATION FOR UNITY OF TITLE CAN BE | | | DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | KELLY CRANFORD, P.E. | | | CAPITAL IMPROVEMENT PLAN MANAGER | | | [email protected] | | | 561-494-1098 (OFFICE) | | | | | | VINCE NOEL, PSM | | | CITY SURVEYOR / REAL ESTATE SUPERVISOR | | | [email protected] | | | 561-494-1096 | | | | | | BRIAN COLLINS, PE | | | CITY TRAFFIC ENGINEER | | | [email protected] | | | 561-494-1040 | | | | | | FERDINAND RIVERA | | | PUBLIC WORKS OPERATIONS MANAGER | | | [email protected] | | | 561-822-2076 | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | 561-494-1120 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
02-09-2016 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
02-09-2016 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
02-09-2016 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2016-02-09 16:00:05 | 2ND REVIEW RESPONSE | | | | | | AFTER A REVIEW OF THE PPRC RESPONSE LETTER DATED | | | FEBRUARY 4, 2016, FROM THE CONSTRUCTIONAND ARCHITECTURE | | | GROUP, AND MEMO FROM DANEIELLE KITTREDGE, SENIOR | | | PLANNER, THE PREVIOUSLY SUBMITTED FIRE PREVENTION | | | BUREAU COMMENTS HAVE BEEN ADDRESSED. | | | | | | THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES | | | NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
12-04-2015 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
12-04-2015 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
12-04-2015 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2015-12-04 13:24:41 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. SHEET CVR - INDICATES A REFERENCE TO A PET BOARDING | | | BUSINESS AND A OFFICE EDUCATIONAL OCCUPANCY, | | | CLARRIFICATION IS NEEDED. | | | | | | 7. SHEET SP 2 - REQUIRES A REVIEW OF THE EXIT DOORS AND | | | EXIT LOCATIONS. THERE APPEARS TO BE INSUFFIECENT NUMBER | | | OF EXITS AND EXIT REMOTENESS FROM THE | | | EDUCATIONAL/OFFICE AREA. | | | | | | 8. SHEET SP 2 - THE DOUBLE DOORS TO THE HALL NEED TO | | | SWING IN THE DIRECTION OF EGRESS. | | | | | | 9. SHEETS SP 2 - THE BATHROOM DOOR SHALL NOT SWING INTO | | | THE EXIT CORRIDOR. | | | | | | 10. SHEET CVR - THE PROPOSED PROJECT SHALL MEET THE | | | REQUIREMENTS OF THE 5TH EDITION OF FLORIDA FIRE | | | PREVENTION CODE INCLUDING THE 2012 EDITION OF NFPA 1 | | | AND NFPA 101 AND ALL OTHER APPLICABLE CODES OR | | | STANDARDS. ADDITIONALLY, INDICATE WHAT OCCUPANY CODE | | | YOU WILL BE USING TO DESIGN THE PROPOSED BUILDING. | | | | | | 11. ALL KITCHEN EQUIPMENT AND OPERATIONS SHALL COMPLY | | | WITH NFPA 96, STANDARD FOR VENTILATION CONTROL AND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS. | | | EXTINGUISHMENT AND VENTILATION SYSTEM SHOP DRAWINGS | | | SHALL BE SUBMITTED SEPARATELY FOR APPROVAL. | | | | | | 12. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 13. PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED | | | FOR STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR ANY | | | MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE | | | WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED | | | WITH A MALTESE CROSS SIGN MEASURING 8 INCHES | | | HORIZONTALLY AND 8 INCHES VERTICALLY, OF A BRIGHT RED | | | REFLECTIVE COLOR. THE APPROVED SYMBOL SHALL BE PLACED | | | WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY DOOR. | | | A. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER "R". | | | B. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER "F". | | | C. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | 14. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 15. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
02-17-2016 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
02-17-2016 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
02-17-2016 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2016-02-17 16:44:59 | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: IN TIME CHURCH OF GOD IN CHRIST Z15110007 | | | FEBRUARY 16, 2016 | | | STAFF HAS REVIEWED THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS FOR THE ABOVE REFERENCED PETITION AND | | | PROVIDES THE FOLLOWING COMMENTS: | | | | | | 1. SATISFIED. PLEASE PROVIDE A LANDSCAPE PLAN SIGNED | | | AND SEALED BY A LANDSCAPE ARCHITECT PER SECTION 94-448 | | | (D)(2)R. | | | | | | 2. SATISFIED. THE MINIMUM LANDSCAPE AREA REQUIRED IS | | | 15%. PLEASE REVISE THE SITE AND LANDSCAPE PLANS TO SHOW | | | THE PROPOSED LANDSCAPE AREA MEETS THE MINIMUM REQUIRED. | | | | | | 3. CONDITIONALLY SATISFIED. PLEASE CALCULATE THE NUMBER | | | OF SHADE, FLOWERING TREES AND SHRUBS REQUIRED BASED ON | | | THE REQUIRED 40% OPEN SPACE FOR THE SITE PER SECTION | | | 94-442(B)(2)B. | | | | | | 4. CONDITIONALLY SATISFIED. PLEASE IDENTIFY EXISTING | | | TREES ON THE PROPERTY AND INDICATE THE SPECIES, SIZE, | | | AND IF THEY WILL BE REMOVED, RELOCATED, OR REMAIN. | | | PLEASE PROVIDE A MITIGATION CHART TO REFLECT THE TREE | | | INVENTORY, AND PROVIDE PERTINENT INFORMATION FOR EACH | | | TREE PER SECTION 94-448 (E) INCLUDING SPECIES, CANOPY | | | SIZE AND REPLACEMENT REQUIREMENT FOR ANY TREES PROPOSED | | | TO BE REMOVED. | | | | | | 5. CONDITIONALLY SATISFIED. PLEASE INDICATE THE | | | REQUIRED 5 FOOT LANDSCAPE BUFFER AT THE PERIMETER OF | | | THE PROPERTY, AND PROVIDE TREES AND HEDGES PER SECTION | | | 94-443(B) AND TABLE XIV-1. PLEASE CALCULATE THE LENGTH | | | OF EACH BUFFER AND PROVIDE A TREE FOR EACH 30 FEET OR | | | PORTION THEREOF. | | | | | | 6. SATISFIED. PLEASE PROVIDE A LANDSCAPE ISLAND AND | | | TREE AT THE END OF THE ROWS OF PARKING PER SECTION | | | 94-443(C)(3)A. | | | | | | 7. SATISFIED. PLEASE PROVIDE A LANDSCAPE ISLAND AND | | | TREE SO THAT THERE ARE NO MORE THAN 10 PARKING SPACES | | | IN A ROW OF PARKING PER SECTION 94-443(C)(3)B. | | | | | | 8. SATISFIED. PLEASE PROVIDE WATER NEEDS CATEGORY FOR | | | EACH SPECIES ON THE PLANT LIST FROM THE SFWMD WATERWISE | | | GUIDE AND SHOW COMPLIANCE WITH THE FLORIDA FRIENDLY | | | LANDSCAPE CHART SECTION 94-442 (G). | | | | | | 9. CONDITIONALLY SATISFIED. PLEASE REVISE THE LANDSCAPE | | | AND ENGINEERING PLANS TO SHOW LOCATIONS OF ANY LIGHTING | | | OR FPL EQUIPMENT AND LOCATIONS OF MECHANICAL EQUIPMENT | | | SUCH AS A/C COMPRESSORS ADJUST CONFLICTS BETWEEN | | | LANDSCAPING AND PROVIDE SCREENING FOR ALL GROUND | | | MOUNTED EQUIPMENT AND UTILITIES. | | | | | | 10. CONDITIONALLY SATISFIED. PLEASE SHOW LOCATIONS OF | | | ROOT BARRIERS TO PROTECT INFRASTRUCTURE AND TREES FROM | | | CONFLICTS. THIS INCLUDES WATER, SEWER, DRAINAGE, | | | SIDEWALKS AND CURBS, AND ANY FIELD STRUCTURES THAT | | | COULD BE IMPACTED BY TREE ROOTS. | | | | | | | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | 2. PRIOR TO APPLICATION FOR A LANDSCAPE PERMIT, THE | | | APPLICANT SHALL OBTAIN FINAL SITE PLAN APPROVAL AND | | | SHALL REVISE THE LANDSCAPE PLAN TO CALCULATE THE | | | REQUIRED NUMBER OF SHADE TREES AND FLOWERING TREES | | | BASED ON THE PERVIOUS AREA FOR THE ENTIRE SITE AS | | | APPROVED, AND PROVIDE THE REQUIRED NUMBER OF TREES FOR | | | THE ENTIRE SITE. | | | | | | 3. PRIOR TO APPLICATION FOR A LANDSCAPE PERMIT, THE | | | APPLICANT SHALL OBTAIN FINAL SITE PLAN APPROVAL AND | | | SHALL REVISE THE LANDSCAPE PLANS TO SHOW LOCATIONS OF | | | ANY LIGHTING OR FPL EQUIPMENT AND LOCATIONS OF | | | MECHANICAL EQUIPMENT SUCH AS A/C COMPRESSORS AND | | | PROVIDE SCREENING FOR ALL GROUND MOUNTED EQUIPMENT AND | | | UTILITIES. | | | | | | 4. PRIOR TO APPLICATION FOR A LANDSCAPE PERMIT, THE | | | APPLICANT SHALL OBTAIN FINAL SITE PLAN APPROVAL AND | | | SHALL REVISE THE LANDSCAPE AND ENGINEERING PLANS TO | | | SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT | | | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES | | | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY | | | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | 5. PRIOR TO APPLICATION FOR A LANDSCAPE PERMIT, THE | | | APPLICANT SHALL OBTAIN FINAL SITE PLAN APPROVAL AND | | | SHALL REVISE THE LANDSCAPE PLAN TO INDICATE A 5 FOOT | | | LANDSCAPE BUFFER AT THE PERIMETER OF THE PROPERTY, AND | | | PROVIDE TREES AND HEDGES PER SECTION 94-443(B) AND | | | TABLE XIV-1 WHERE POSSIBLE. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
12-04-2015 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
12-04-2015 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
12-04-2015 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2015-12-04 09:11:31 | FROM: RAY CARANCI, LANDSCAPE PLANNER | | | PROJECT: IN TIME CHURCH OF GOD IN CHRIST Z15110007 | | | DECEMBER 4, 2015 | | | STAFF HAS REVIEWED THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS FOR THE ABOVE REFERENCED PETITION AND | | | PROVIDES THE FOLLOWING COMMENTS: | | | | | | 1. PLEASE PROVIDE A LANDSCAPE PLAN SIGNED AND SEALED BY | | | A LANDSCAPE ARCHITECT PER SECTION 94-448 (D)(2)R. | | | | | | 2. THE MINIMUM LANDSCAPE AREA REQUIRED IS 15%. PLEASE | | | REVISE THE SITE AND LANDSCAPE PLANS TO SHOW THE | | | PROPOSED LANDSCAPE AREA MEETS THE MINIMUM REQUIRED. | | | | | | 3. PLEASE CALCULATE THE NUMBER OF SHADE, FLOWERING | | | TREES AND SHRUBS REQUIRED BASED ON THE REQUIRED 40% | | | OPEN SPACE FOR THE SITE PER SECTION 94-442(B)(2)B. | | | | | | 4. PLEASE IDENTIFY EXISTING TREES ON THE PROPERTY AND | | | INDICATE THE SPECIES, SIZE, AND IF THEY WILL BE | | | REMOVED, RELOCATED, OR REMAIN. PLEASE PROVIDE A | | | MITIGATION CHART TO REFLECT THE TREE INVENTORY, AND | | | PROVIDE PERTINENT INFORMATION FOR EACH TREE PER SECTION | | | 94-448 (E) INCLUDING SPECIES, CANOPY SIZE AND | | | REPLACEMENT REQUIREMENT FOR ANY TREES PROPOSED TO BE | | | REMOVED. | | | | | | 5. PLEASE INDICATE THE REQUIRED 5 FOOT LANDSCAPE BUFFER | | | AT THE PERIMETER OF THE PROPERTY, AND PROVIDE TREES AND | | | HEDGES PER SECTION 94-443(B) AND TABLE XIV-1. PLEASE | | | CALCULATE THE LENGTH OF EACH BUFFER AND PROVIDE A TREE | | | FOR EACH 30 FEET OR PORTION THEREOF. | | | | | | 6. PLEASE PROVIDE A LANDSCAPE ISLAND AND TREE AT THE | | | END OF THE ROWS OF PARKING PER SECTION 94-443(C)(3)A. | | | | | | 7. PLEASE PROVIDE A LANDSCAPE ISLAND AND TREE SO THAT | | | THERE ARE NO MORE THAN 10 PARKING SPACES IN A ROW OF | | | PARKING PER SECTION 94-443(C)(3)B. | | | | | | 8. PLEASE PROVIDE WATER NEEDS CATEGORY FOR EACH SPECIES | | | ON THE PLANT LIST FROM THE SFWMD WATERWISE GUIDE AND | | | SHOW COMPLIANCE WITH THE FLORIDA FRIENDLY LANDSCAPE | | | CHART SECTION 94-442 (G). | | | | | | 9. PLEASE REVISE THE LANDSCAPE AND ENGINEERING PLANS TO | | | SHOW LOCATIONS OF ANY LIGHTING OR FPL EQUIPMENT AND | | | LOCATIONS OF MECHANICAL EQUIPMENT SUCH AS A/C | | | COMPRESSORS ADJUST CONFLICTS BETWEEN LANDSCAPING AND | | | AND PROVIDE SCREENING FOR ALL GROUND MOUNTED EQUIPMENT | | | AND UTILITIES. | | | | | | 10. PLEASE SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT | | | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES | | | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY | | | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | PLEASE UNDERSTAND THAT ADDITIONAL INFORMATION MAY BE | | | REQUESTED, AND STAFF MAY HAVE ADDITIONAL COMMENTS AS | | | THE REVIEW PROCESS CONTINUES. | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
F |
Date |
03-14-2016 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-14-2016 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-14-2016 |
Time |
10:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
12-07-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
12-07-2015 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
12-07-2015 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2015-12-07 11:44:31 | SEE COMMENTS UNDER ENG PPRC. |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2016-02-16 11:18:47 | 1. ADD SWALE ON WEST SIDE OF PROPOSED HALL BUILDING TO | | | CONVEY RUNOFF TO PROPOSED RETENTION AREAS. | | | | | | 2. GRADING PLAN WILL NEED TO BE SUBMITTED SHOWING THE | | | DEPTH OF THE PROPOSED RETENTION AREAS AND HOW SITE WILL | | | DRAIN. | | | | | | 3. CONSIDER EXPANDING THE EAST PROPOSED RETENTION AREA | | | TO BE "SAW-TOOTH" BY FOLLOWING THE SHAPE OF THE PARKING | | | STALLS INSTEAD OF BEING A LONG, LINEAR | | | "SWALE". | | | | | | TRACY L. WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | PUBLIC WORKS DEPARTMENT | | | 561-494-1120 | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
12-07-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
12-07-2015 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
12-07-2015 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2015-12-07 11:43:59 | SEE COMMENTS UNDER ENG PPRC. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
P |
Date |
12-07-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
12-07-2015 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
12-07-2015 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
P |
Date |
12-07-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
12-07-2015 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
12-07-2015 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
03-01-2016 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
03-01-2016 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2016-03-01 09:10:25 | PLANNING AND ZONING COMMENTS: | | | | | | 3/1/16 | | | | | | CONDITIONS OF CLASS B SPECIAL USE PERMIT: | | | | | | THE SITE PLAN IN ASSOCIATION WITH THE CLASS B SPECIAL | | | USE PERMIT IS APPROVED WITH THE FOLLOWING CONDITIONS TO | | | ADDRESS AT TIME OF BUILDING PERMIT SUBMITTAL: | | | | | | 1. UPDATE SHEET CVR TO REFLECT UPDATED CALCULATIONS AS | | | SHOWN ON THE SITE PLAN (SHEET SP-2). | | | | | | 2. REVISED PLAN STILL DOES NOT SHOW ADA SPACES WITH | | | CONNECTED LINES AT THE BOTTOM. PLEASE REVISE. | | | | | | 3. ADD STRIPING DETAIL FOR ANGLED PARKING. | | | | | | 4. AN ADDITIONAL DETAIL FOR THE BICYCLE RACK SPACING | | | SHALL BE INCLUDED TO SHOW A MINIMUM OF 36 INCHES | | | BETWEEN RACKS AND A MINIMUM OF 24 INCHES BETWEEN RACK | | | AND EDGE OF CONCRETE PAD. THE LENGTH OF THE PAD SHALL | | | BE A MINIMUM OF 6 FEET. | | | | | | 5. PROVIDE SURVEY ABSTRACTED FOR EASEMENTS. | | | | | | 6. OBTAIN AN EASEMENT CONSENT FORM SIGN-OFF FROM AT&T | | | FOR SITE IMPROVEMENTS LOCATED WITHIN THE AT&T EASEMENT. | | | | | | 7. INCLUDE OVERALL BUILDING HEIGHT ON BUILDING | | | ELEVATIONS. | | | | | | 8. THE APPLICANT SHALL UNIFY ALL PROPERTY BY SUBMITTING | | | AN APPLICATION FOR A UNITY OF TITLE THROUGH THE CITY'S | | | ENGINEERING AND PUBLIC WORKS DEPARTMENT. | | | | | | 9. THE LANDSCAPE PLAN SHALL BE UPDATED TO INCLUDE | | | LANDSCAPING IMPROVEMENTS FOR THE SOUTHERN PORTION THE | | | PROPERTY. LANDSCAPING IMPROVEMENT SHALL BE INCOMPLIANCE | | | WITH THE CITY'S ZLDRS. | | | | | | 10. UPDATE ENGINEERING PLANS TO REMOVE GRASS PARKING | | | AND ADD CURBING AND WHEEL STOPS TO PROTECT LANDSCAPED | | | AREAS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
02-16-2016 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
02-16-2016 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
02-04-2016 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2016-02-16 18:01:13 | PLANNING AND ZONING COMMENTS ***FAILED*** | | | | | | 2/16/16 | | | | | | 1. PRINTED SITE PLAN DOES NOT MATCH DIGITAL RED-LINED | | | PLAN SUBMITTED. ZONING COMMENTS WERE MADE REVIEWING THE | | | RED-LINED SITE PLAN WHICH APPEARS TO BE MORE UP TO DATE | | | THAN THE SUBMITTED PAPER PLANS. | | | | | | 2. INCLUDE SETBACK DIMENSIONED ALONG SOUTH SIDE OF THE | | | PROPERTY. | | | | | | 3. WHAT IS THE NOTATION NEXT TO THE ADA RAMP BY | | | 'PROPOSED HALL' BUILDING? | | | | | | 4. ENGINEERING PLANS INDICATE PARKING SPACES AROUND THE | | | PROPOSED HALL BUILDING WILL BE STABILIZED TURF. PARKING | | | ON GRASS IS NOT PERMITTED. PARKING SPACES WILL NEED TO | | | BE PAVED WITH A NONDUSTING SURFACE [ZLDR SEC. | | | 94-485(E)]. IMPERVIOUS/PERVIOUS CALCULATIONS TO BE | | | ADJUSTED ACCORDINGLY FOR ANY CHANGES. | | | | | | 5. HOW IS LANDSCAPING BEING PROTECTED FROM VEHICLES? | | | SHOW LOCATIONS OF CURBING AND WHEEL STOPS. | | | | | | 6. [PREVIOUS COMMENT #3] - PARKING CALCULATION NEEDS TO | | | BE PROVIDED ON THE SITE PLAN. INCLUDE NOTATION THAT | | | THERE ARE 20 SPACES THAT SERVE THE EXISTING BUILDING. | | | THE NEW BUILDING SQUARE FOOTAGE WILL USE THE 1 PER | | | 1,000 ASSEMBLY PARKING RATE UNDER THE PARKING | | | REQUIREMENTS FOR CHURCHES. | | | | | | 7. [PREVIOUS COMMENT #4] - ADA SPACES REQUIRED ARE | | | BASED OFF OF TOTAL PROVIDED PARKING. IF 26 SPACES ARE | | | PROVIDED, TWO OF THE SPACES MUST BE ADA [ZLDR SEC. | | | 94-485(O)(1)]. PLEASE REVISE PLANS. | | | | | | 8. [PREVIOUS COMMENT #5] - PLAN DOES NOT INCLUDE DOUBLE | | | STRIPES CONNECTED AT THE BOTTOM OF ADA SPACES AND 12? | | | SPACING BETWEEN LINES. PLEASE REVISE. IF YOU NEED A | | | COPY OF THE STANDARD CITY DETAIL, PLEASE CONTACT ME. | | | STRIPING DETAIL WILL NEED TO BE PROVIDED FOR 40 DEGREE | | | ANGLE PARKING. | | | | | | 9. [PREVIOUS COMMENT #8] - DIMENSION AISLE/BACK-UP | | | SPACE BEHIND PARKING SPACES 11 THROUGH 15. MINIMUM | | | AISLE IS 24 FEET FOR 90 DEGREE ANGLE PARKING. | | | | | | 10. [PREVIOUS COMMENT #10] - BUILDING ELEVATIONS NOT | | | PROVIDED ON SHEET SP-2 AS INDICATED. PLEASE PROVIDE. | | | | | | 11. [PREVIOUS COMMENT #12] - WHILE THE SITE IS ADDING | | | LESS THAN 20 NEW SPACES, THE TOTAL PROPOSED PARKING | | | SPACES IS 26 AND TWO BICYCLE PARKING SPACES WILL BE | | | REQUIRED. PLEASE INCLUDE LOCATION WITH PAD AND RACK | | | DETAIL. | | | | | | 12. [PREVIOUS COMMENT #13] - NOTATION ADDED TO THE PLAN | | | INDICATES THAT 'LOADING ZONE NOT TO BE USED WHEN PEOPLE | | | ARE OCCUPYING THE BUILDING'. THIS SEEMS A BIT | | | IMPRACTICAL IF SOMEONE IS SETTING UP FOR AN EVENT WHERE | | | PEOPLE NEED TO BE IN THE BUILDING TO RECEIVE THE | | | DELIVERY. IT IS RECOMMENDED THE NOTATION BE SOMETHING | | | SIMILAR TO THE EFFECT THAT THE LOADING IS ONLY FOR | | | OFF-PEAK HOURS OF USE. | | | | | | 13. [PREVIOUS COMMENT #14] - WAIVER TO MINIMUM AMOUNT | | | OF OPEN SPACE HAS BEEN REQUESTED, BUT NO JUSTIFICATION | | | OR RESPONSE TO WAIVER STANDARDS PROVIDED. PLEASE | | | PROVIDE DOCUMENTATION JUSTIFYING THE WAIVER REQUEST AND | | | RESPONSE TO WAIVER STANDARDS ZLDR SECTION 94-273(A)(2). | | | ADDITIONAL FEE REQUIRED FOR WAIVER - $270. PLEASE | | | REVIEW AND PROVIDE A GRAPHIC OF HOW THE PERVIOUS AREA | | | OF 35% WAS ARRIVED AT. IT APPEARS THAT THE PERVIOUS | | | AREA IS MUCH LESS THAN 35%. | | | | | | 14. [PREVIOUS COMMENT #15] - ADDITIONAL INFORMATION | | | ADDED TO LEGAL DESCRIPTION REFERENCES PLAT BOOK AND | | | PAGE NUMBER, ONE OF WHICH DOES NOT PERTAIN TO THE | | | PROPERTY. ADDITIONAL LOTS WERE NOT ADDED TO THE LEGAL | | | DESCRIPTION. PLEASE REVIEW PROPERTY SURVEY FOR CORRECT | | | INFORMATION. | | | | | | 15. [PREVIOUS COMMENT #19] - SURVEY ABSTRACTED FOR | | | EASEMENT WAS NOT PROVIDED. | | | | | | 16. [PREVIOUS COMMENT #20] - AT&T EASEMENT WAS NOT | | | NOTATED ON THE SITE PLAN. EASEMENT CONSENT FORM WILL BE | | | REQUIRED FROM AT&T FOR ALL IMPROVEMENTS PROPOSED IN THE | | | EASEMENT. PLEASE PROVIDE. | | | | | | 17. [PREVIOUS COMMENT #23] - IF ALL TRASH RECEPTACLES | | | WILL BE STORED INDOORS, PLEASE INCLUDE NOTATION ON | | | PLAN. ROLLOUT CONTAINERS, RATHER THAN A DUMPSTER WILL | | | NEED TO BE APPROVED BY THE CITY'S SANITATION DIVISION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
12-04-2015 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
12-04-2015 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
12-03-2015 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2015-12-04 16:42:23 | PLANNING AND ZONING COMMENTS: | | | | | | 12/4/15 | | | | | | 1. CORRECT THE WEST SETBACK ON SHEET SP-2. THE WEST | | | SIDE IS ALONG A STREET AND CONSIDERED A CORNER SETBACK | | | WHICH NEEDS TO BE DEPICTED AS 12.5 FEET RATHER THAN 5 | | | FEET [ZLDR SEC. 94-74(A)(3)(B)]. | | | | | | 2. CORRECT SHEET SP-2 'UTILITY SERVICE' PROVIDER TO | | | CITY OF WEST PALM BEACH RATHER THAN PALM BEACH COUNTY | | | UTILITIES. | | | | | | 3. INDICATE THE BREAKDOWN OF THE PARKING CALCULATION | | | FOR THE SITE. PLAN SHOULD INDICATE THAT THERE ARE 20 | | | SPACES REQUIRED FOR THE CHURCH (PER A PREVIOUS | | | APPROVAL) AND HOW THE ADDITIONAL 7 NEW SPACES WERE | | | ARRIVED AT. WHAT USES AND CALCULATION WERE USED? | | | | | | 4. THE SITE PROVIDES ONE ADA SPACE. ZLDR SEC. 94-485(O) | | | REQUIRES PARKING LOTS WITH 26-50 PARKING SPACES PROVIDE | | | TWO ADA SPACES. PLEASE UPDATE THE PLAN. | | | | | | 5. REVISE ADA STRIPING DETAIL TO INCLUDE STRIPES | | | CONNECTED AT THE BOTTOMS AND SPACED CORRECTLY. | | | | | | 6. ONE INTERIOR LANDSCAPE ISLAND IS REQUIRED FOR EVERY | | | TEN PARKING SPACES. AN INTERIOR LANDSCAPE ISLAND WILL | | | BE REQUIRED IN THE ROW OF 12 PARKING SPACES SHOWN ON | | | THE PLAN [ZLDR SEC. 94-443(C)(3)(B)]. | | | | | | 7. AN ADDITIONAL STRIPED AREA NEEDS TO BE PROVIDED AT | | | THE END OF THE LAST PARKING SPACE TO THE NORTH TO SERVE | | | AS A TURNAROUND SPACE IF SOMEONE DRIVES DOWN TO THE END | | | AND ALL SPACES ARE FULL. | | | | | | 8. MINIMUM DRIVE AISLE WIDTH FOR 90 DEGREE PARKING WITH | | | A TWO-WAY DRIVE IS 24 FEET AND THE PLAN SHOWS 20 FEET | | | [ZLDR SEC. 94-485(J)]. PLEASE REVISE. | | | | | | 9. AT MINIMUM, THE NORTHERN DRIVEWAY INGRESS/EGRESS | | | POINT NEEDS TO BE A MINIMUM OF 24 FEET IN WIDTH TO | | | ACCOMMODATE TWO-WAY TRAFFIC. PLEASE REVISE. | | | | | | 10. PROVIDE BUILDING ELEVATIONS AND INDICATE BUILDING | | | HEIGHT. BUILDING HEIGHT SHALL NOT EXCEED 30 FEET [ZLDR | | | SEC. 94-74(A)(4)]. | | | | | | 11. PROVIDE DIMENSIONS OF NEW BUILDING FOOTPRINT ON THE | | | SITE PLAN. | | | | | | 12. PROVIDE BICYCLE PARKING FOR NEW PARKING IN | | | ACCORDANCE WITH ZLDR SEC. 94-485(Q) AND INCLUDE DETAIL | | | OF RACK AND SPACING ON THE PLANS. | | | | | | 13. IDENTIFY LOADING ZONE IN ACCORDANCE WITH ZLDR SEC. | | | 94-485(P). | | | | | | 14. IN THE SITE INFORMATION TABLE THE 'PERVIOUS LOT | | | AREA PROVIDED' IS INDICATED TO BE 40%. (WHILE THE FINAL | | | NUMBER IS CORRECT, I AM UNCLEAR ABOUT THE REASON BEHIND | | | THE METHOD OF THE CALCULATION.) THIS 'PROVIDED' 40% IS | | | DIFFERENT FROM TOTAL GREEN SPACE (8,251 SQ. FT. OR 31%) | | | PROVIDED AT THE END OF THE TABLE. PLEASE REVIEW FOR | | | ACCURACY. THE ADDITIONAL STANDARDS FOR CHURCHES | | | REQUIRES THAT THE SITE SHALL NOT EXCEED 60% IMPERVIOUS | | | AREA [ZLDR SEC. 94-273(D)(8)]. PLEASE DEMONSTRATE | | | COMPLIANCE WITH THIS REQUIREMENT OR REQUEST A WAIVER | | | AND PROVIDE JUSTIFICATION. | | | | | | 15. PLEASE REVIEW THE 'LEGAL DESCRIPTION' PROVIDED IN | | | THE SITE INFORMATION TABLE WHICH SEEMS TO ONLY INCLUDE | | | ONE PORTION OF THE PROPERTY. | | | | | | 16. NOTATE ON THE SITE PLAN THAT THE ALLEY IS TO BE | | | ABANDONED AND THE AREA OF THE ALLEY HAS BEEN INCLUDED | | | IN THE SITE CALCULATIONS. | | | | | | 17. UPDATE THE DISTANCE DIMENSION FIGURE ON SHEET SP-2 | | | TO DEMONSTRATE THE DISTANCE OF THE BUILDING AND | | | PARKING/CIRCULATION AREAS ARE A MINIMUM OF 30 FEET FROM | | | A RESIDENTIAL PROPERTY LINE RATHER THAN A RESIDENTIAL | | | STRUCTURE. WAIVERS WILL BE REQUIRED FROM THE | | | RESIDENTIAL PROPERTY LINE TO THE EAST. PLEASE REVIEW | | | AND ADJUST THE GRAPHIC, JUSTIFICATION STATEMENT, AND | | | RESPONSE TO ADDITIONAL STANDARDS APPROPRIATELY. FOR | | | EACH WAIVER REQUEST THERE IS A $270 FEE. BASED ON | | | REVIEW OF THE PLAN TWO WAIVER WILL BE NEEDED FROM ZLDR | | | SEC. 94-273(D)8)(B)(2)(I) AND (II). | | | | | | 18. IS THERE ANY NEW OUTDOOR LIGHTING BEING PROPOSED | | | FOR THE SITE? IF YES, PROVIDE A PHOTOMETRIC PLAN AND | | | INDICATE LOCATION OF LIGHTS. FOR LIGHT POLES INDICATE | | | POLE HEIGHT AND SETBACK ON THE SITE PLAN. THE LIGHT | | | POLES MUST COMPLY WITH THE PROPERTY SETBACKS. | | | | | | 19. PROVIDE AN UPDATED SURVEY ABSTRACTED FOR EASEMENTS. | | | | | | 20. NOTATE ON SITE PLAN THE AT&T EASEMENT. PROVIDE AN | | | EASEMENT CONSENT FROM AT&T FOR IMPROVEMENTS PROPOSED | | | WITHIN THE AT&T EASEMENT AREA. | | | | | | 21. IN REVIEW OF THE PLAN, STAFF SUGGESTS LOOKING AT | | | THE FEASIBILITY OF PLACING THE NEW BUILDING DIRECTLY TO | | | THE WEST OF THE EXISTING BUILDING AND USING THE REAR OF | | | LOT TO CONSTRUCT A SINGLE CONSOLIDATED PARKING FACILITY | | | FOR THE SITE. | | | | | | 22. ARE THERE ANY CHANGES BEING PROPOSED TO THE | | | EXISTING CHAIN-LINK FENCE? THE EXISTING FENCE IS | | | NON-CONFORMING IN RESPECT TO ITS HEIGHT ALONG THE FRONT | | | SETBACKS. ANY REPLACEMENT OF THE FENCE WILL REQUIRE | | | COMPLIANCE WITH THE FENCE REQUIREMENTS FOR THE ZONING | | | DISTRICT. | | | | | | 23. PROVIDE INFORMATION ON HOW THE TRASH RECEPTACLES | | | WILL BE SCREENED. | | | | | | | | | WHEN RESUBMITTING: | | | A. PROVIDE WRITTEN RESPONSES TO REVIEW COMMENTS MADE BY | | | DEPARTMENTS IN A WRITTEN FORMAT WHEN RESUBMITTING. | | | | | | B. PROVIDE 10 SETS OF REVISED PLANS AND/OR DOCUMENTS | | | ALONG WITH ONE REDUCED COPY AND ELECTRONIC COPY OF ALL | | | PLANS. | | | | | | C. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | D. PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | E. IN ORDER TO BE CONSIDERED FOR THE JANUARY 7, 2016 | | | ZONING BOARD OF APPEALS MEETING, ALL PLANS MUST BE | | | REVISED AND SUBMITTED BY 8:30AM ON MONDAY, DECEMBER 14, | | | 2015. IN ORDER TO BE CONSIDERED FOR THE FEBRUARY 4, | | | 2016 ZONING BOARD OF APPEALS MEETING, ALL PLANS MUST BE | | | REVISED AND SUBMITTED BY MONDAY, JANUARY 11, 2016. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
| |