| Plan Review Stops For Project Z15090031 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
11-20-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
11-20-2015 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
10-14-2015 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
10-14-2015 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
10-14-2015 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2015-10-14 11:06:57 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. NO ACCESSIBLE PARKING SPACES ARE SHOWN ON THE PLANS. | | | THE MINIMUM NUMBER OF ACCESSIBLE PARKING SPACES | | | PROVIDED SHALL BE IN ACCORDANCE WITH SECTION 208.2 OF | | | FLORIDA ACCESSIBILITY CODE. | | | | | | 3. PER SECTION 208.3 OF FLORIDA ACCESSIBILITY CODE, | | | ACCESSIBLE PARKING SPACES ARE TO BE LOCATED ON THE | | | SHORTEST POSSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING | | | TO AN ACCESSIBLE ENTRANCE FOR EACH BUILDING. THE DESIGN | | | OF ACCESSIBLE PARKING SPACES SHALL COMPLY WITH SECTION | | | 502 OF FLORIDA ACCESSIBILITY CODE | | | | | | 4. ACCESSIBLE PARKING SPACE ACCESS AISLES SHALL BE | | | LOCATED SO THAT THE USER IS NOT COMPELLED TO WALK OR | | | WHEEL BEHIND ANOTHER PARKED VEHICLE OR IN THE TRAVEL | | | LANE. THE ACCESS AISLES SHALL ALSO COMPLY WITH THE | | | OTHER PROVISIONS OF SECTION OF 502.3 OF FLORIDA | | | ACCESSIBILITY CODE. | | | | | | 5. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
F |
Date |
11-20-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
11-20-2015 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
11-20-2015 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2015-11-20 09:15:19 | PUBLIC WORKS STAFF HAVE REVIEWED THE APPLICATION FOR | | | CONSISTENCY WITH GENERAL AND ENGINEERING PROVISIONS OF | | | THE CODE AND THE LAND DEVELOPMENT REGULATIONS. BASED ON | | | THE INFORMATION SUBMITTED TO DATE, WE RECOMMEND THE | | | FOLLOWING CONDITIONS BE INCORPORATED INTO ANY SITE PLAN | | | APPROVAL. | | | | | | E1. PRIOR TO START OF CONSTRUCTION, ENGINEERING | | | DEVELOPMENT APPROVAL AND A UNITY OF TITLE ARE REQUIRED. | | | FINAL DESIGN MUST MEET CITY CODES AND STANDARDS. | | | | | | E2. PRIOR TO ISSUANCE OF ENGINEERING DEVELOPMENT | | | APPROVAL, THE DEVELOPER SHALL DEMONSTRATE THAT THE | | | EXISTING STORMWATER TREATMENT SYSTEM, INCLUDING THE 540 | | | GALLON SAND TRAP AND GREASE TRAP, IS IN GOOD CONDITION | | | AND FUNCTIONS AS PREVIOUSLY DESIGNED. | | | | | | E3. THE SURVEY MUST BE COMPLETE AND ACCURATE INCLUDING | | | INFORMATION FROM FDOT MAINTENANCE MAPS FOR BROADWAY, | | | SHOWING ALL PROPERTY CORNERS, AND ACCURATELY REFLECTING | | | THE PROPERTY LINE. |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
10-14-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
10-14-2015 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
10-14-2015 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2015-10-14 08:15:40 | CITY OF WEST PALM BEACH | | | PUBLIC WORKS DEPARTMENT | | | | | | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | BUILDING PERMIT APPLICATION PROCESSES. | | | | | | 1. SITE PLAN DOES NOT CONTAIN ENOUGH INFORMATION TO | | | EVALUATE THE PROPOSED DESIGN. | | | | | | 2. PLEASE SHOW THE LOCATION OF THE PROPOSED DUMPSTER | | | ENCLOSURE. THE ENCLOSURE SHOULD MEET THE MINIMUM | | | DIMENSIONAL REQUIREMENTS FOR THE ENCLOSURE AS LISTED IN | | | CODE OF ORDINANCES, SECTION 94-444(B), ALSO SEE FIGURE | | | XIV-3 OF THE SAME SECTION. | | | | | | 3. THE WATER QUALITY TREATMENT FOR THE PREVIOUS CAR | | | WASH WAS TREATED IN A 540 GALLON SAND TRAP NEAR THE | | | SOUTHERN PROPERTY LINE. WHAT IS THE CONDITION OF THE | | | TRAP? | | | | | | 4. PLEASE VERIFY THAT THE PREVIOUSLY APPROVED DRAINAGE | | | SYSTEM, WHICH DIRECTED RUNOFF TO THE CENTER OF THE | | | PROJECT, IS STILL IN PLACE AND IN GOOD CONDITION. | | | | | | 5. WILL THE WASH WATER BE RECYCLED? THE WATER CANNOT BE | | | DIRECTED TO THE SANITY SYSTEM WITHOUT THE INSTALLATION | | | OF AN INTERCEPTOR (ORDINANCE 90-125). WASH WATER MAY | | | NOT BE DIRECTED TO THE STORMWATER SYSTEM. PREFERABLY, | | | THE WASH WATER SHOULD BE COLLECTED IN A WASH PIT AND | | | DISPOSED OF BY AN INDUSTRIAL WASTE COMPANY. | | | | | | 6. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE | | | AVAILABLE AT HTTP://WWW.CO.PALM-BEACH.FL.US/NEWSROOM/08 | | | 14/08-26-14-FLOOD_MAPS.HTM. PLEASE REVIEW THE MAPS AND | | | VERIFY THAT THE NEW MAPS WILL NOT IMPACT THE PROPOSED | | | PROJECT. | | | | | | 7. THE SUBMITTED SURVEY DOES NOT APPEAR TO BE COMPLETE | | | AND ACCURATE. PLEASE REFER TO FDOT MAINTENANCE MAPS FOR | | | BROADWAY. PROPERTY CORNERS ARE MISSING. THE PROPERTY | | | LINE IS SHOW TO INCLUDE THE SIDEWALK ON THE WEST SIDE | | | OF BROADWAY. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO | | | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. A UNITY OF TITLE APPLICATION WILL BE REQUIRED FROM | | | THE ENGINEERING DIVISION OF THE PUBLIC WORKS | | | DEPARTMENT. THE APPLICATION FOR UNITY OF TITLE CAN BE | | | DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 2. DETAILS SHEETS WILL NEED TO UTILIZE STANDARD CITY OF | | | WEST PALM BEACH DETAILS, WHICH MAY BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | KELLY CRANFORD, P.E. | | | LAND DEVELOPMENT ENGINEER | | | [email protected] | | | 561-494-1098 (OFFICE) | | | | | | VINCE NOEL, PSM | | | CITY SURVEYOR / REAL ESTATE SUPERVISOR | | | [email protected] | | | 561-494-1096 | | | | | | BRIAN COLLINS, PE | | | CITY TRAFFIC ENGINEER | | | [email protected] | | | 561-494-1040 | | | | | | FERDINAND RIVERA | | | PUBLIC WORKS OPERATIONS MANAGER | | | [email protected] | | | 561-822-2076 | | | | | | TRACY WARD, PE | | | SENIOR STORMWATER ENGINEER | | | 561-494-1120 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
10-09-2015 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
10-09-2015 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
10-09-2015 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2015-10-09 13:01:12 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE 5TH EDITION OF THE FLORIDA FIRE PREVENTION CODE, | | | INCLUDING NFPA 1 & 101, AND ALL ASSOCIATED FIRE CODES. | | | | | | 6. ALL ILLUMINATED EXIT SIGNS AND EMERGENCY LIGHTING | | | EQUIPMENT SHALL BE ILLUSTRATED ON THE PLAN. | | | | | | 7. ALL PORTABLE FIRE EXTINGUISHERS LOCATIONS SHALL BE | | | CLEARLY IDENTIFIED AND INDICATED ON THE PLAN. | | | | | | 8. PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED | | | FOR STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR ANY | | | MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE | | | WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED | | | WITH A MALTESE CROSS SIGN MEASURING 8 INCHES | | | HORIZONTALLY AND 8 INCHES VERTICALLY, OF A BRIGHT RED | | | REFLECTIVE COLOR. THE APPROVED SYMBOL SHALL BE PLACED | | | WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY DOOR. | | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER "R". | | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER "F". | | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | 9. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES | | | NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 10. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
10-13-2015 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
10-13-2015 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
10-13-2015 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2015-10-13 14:43:50 | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND | | | PROVIDE THE FOLLOWING COMMENTS: | | | | | | 1. PLEASE PROVIDE A LANDSCAPE PLAN MEETING THE | | | REQUIREMENTS OF SECTION 94-448(D)(2) LANDSCAPE PLAN | | | REQUIREMENTS. | | | RAY CARANCI, LANDSCAPE PLANNER | | | 561-822-1462 | | | |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
11-20-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
11-20-2015 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
11-20-2015 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
10-14-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
10-14-2015 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
10-14-2015 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2015-10-14 08:16:40 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
F |
Date |
11-20-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
11-20-2015 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
11-20-2015 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2015-11-20 09:16:30 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
10-14-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
10-14-2015 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
10-14-2015 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2015-10-14 08:16:21 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
F |
Date |
11-20-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
11-20-2015 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
11-20-2015 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2015-11-20 09:16:06 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
10-14-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
10-14-2015 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
10-14-2015 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2015-10-14 08:17:11 | SEE COMMENTS UNDER ENG PPRC |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
P |
Date |
11-20-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
11-20-2015 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
11-20-2015 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
P |
Date |
10-14-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
10-14-2015 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
10-14-2015 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
10-13-2016 |
|
|
Cont ID |
|
| Sent By |
|
Date |
10-13-2016 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
10-13-2016 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-10-13 11:54:27 | PLEASE NOTE THAT APPROVAL IS GRANTED WITH THE FOLLOWING | | | CONDITION(S): | | | | | | 1. PRIOR TO START OF CONSTRUCTION, ENGINEERING | | | DEVELOPMENT APPROVAL AND A UNITY OF TITLE ARE REQUIRED. | | | FINAL DESIGN MUST MEET CITY CODE AND STANDARDS. | | | | | | 2. PRIOR TO ISSUANCE OF ENGINEERING DEVELOPMENT | | | APPROVAL, THE DEVELOPER SHALL DEMONSTRATE THAT THE | | | EXISTING STORMWATER TREATMENT SYSTEM, INCLUDING THE 540 | | | GALLON SAND TRAP AND GREASE TRAP, IS IN GOOD CONDITION | | | AND FUNCTIONS AS PREVIOUSLY DESIGNED. | | | | | | 3. PRIOR TO ISSUANCE OF A BUSINESS TAX RECEIPT, THE | | | CITY OF WEST PALM BEACH POLICE DEPARTMENT ? CRIME | | | PREVENTION UNIT SHALL REVIEW AND APPROVE ALL | | | CONSTRUCTION DRAWINGS TO ENSURE THE ADHERENCE TO | | | GENERALLY-ACCEPTED CRIME PREVENTION THROUGH | | | ENVIRONMENTAL DESIGN PRINCIPLES, AS WELL AS COMPLIANCE | | | WITH ALL LOCAL AND STATE REGULATIONS PERTAINING TO THE | | | PROPOSED USE. SUCH SUBMITTAL SHALL INCLUDE A | | | CONSTRUCTION SITE SECURITY AND MANAGEMENT PLAN. | | | | | | 4. THE CAR WASH FACILITY SHALL HAVE THE FOLLOWING | | | RESTRICTIONS: | | | A) HOURS OF OPERATION SHALL BE NO EARLIER THAN 8:00 AM | | | AND NO LATER THAN 7:00 PM. | | | B) AN ATTENDANT IS REQUIRED TO BE PRESENT AT ALL TIME | | | WHEN THE FACILITY IS OPEN. | | | C) ANY VENDING MACHINES ON THE SUBJECT PROPERTY SHALL | | | BE LOCATED WITHIN A FULLY ENCLOSED PORTION OF THE | | | BUILDING. | | | D) THE CLASS B SPECIAL USE PERMIT FOR A CAR WASH | | | FACILITY SHALL EXPIRE AFTER THE USE IS ABANDONED FOR A | | | PERIOD OF MORE THAN 180 CONSECUTIVE DAYS. | | | | | | ALL IMPROVEMENTS MUST BE IMPLEMENTED IN ACCORDANCE WITH | | | THE ABOVE-CITED PLANS, CONDITIONS, AND BUILDING CODE. | | | THIS PROJECT WILL BE SUBJECT TO FINAL ZONING APPROVAL | | | DURING THE BUSINESS TAX PROCESS. PLEASE ALSO BE ADVISED | | | THAT A LANDSCAPE PERMIT WILL BE REQUIRED FOR THE | | | INSTALLATION OF LANDSCAPING ON SITE. | | | | | | IF YOU HAVE ANY QUESTIONS ABOUT THE INFORMATION | | | PRESENTED ABOVE, PLEASE CONTACT PAUL GREILICH, SENIOR | | | PLANNER, AT (561) 822-1443. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
11-17-2015 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
11-17-2015 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
11-12-2015 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2015-11-17 14:59:03 | PLANNING AND ZONING COMMENTS: | | | | | | 11/17/15 | | | | | | 1. [PREVIOUS COMMENT #2.] SITE PLAN NEEDS TO ACCURATELY | | | DEPICT SIDEWALKS. PROPOSED PLAN SHOWS LANDSCAPING IN | | | LOCATION OF EXISTING SIDEWALK ALONG BROADWAY. ACCESS TO | | | PUBLIC SIDEWALK WILL NEED TO REMAIN. THERE IS ALSO A | | | BUS STOP LOCATED ALONG THE BROADWAY SIDE OF THE | | | PROPERTY. | | | | | | 2. [PREVIOUS COMMENT #4.] DIMENSION DRIVE AISLE WIDTHS | | | AND INDICATE IF NEW CURB CUTS ARE PROPOSED OR EXISTING. | | | | | | 3. [PREVIOUS COMMENT #5.] DEPICT PEDESTRIAN ACCESS TO | | | THE SITE. | | | | | | 4. [PREVIOUS COMMENT #8.] INDICATE LAND USE AND ZONING | | | OF THE SUBJECT PROPERTY. THE SUBJECT PROPERTY HAS SPLIT | | | LAND USE AND ZONING WHICH NEEDS TO BE DEPICTED ON THE | | | PLAN. | | | | | | 5. [PART OF PREVIOUS COMMENT #9.] INDICATE ON SITE PLAN | | | THE BUILDING SETBACKS. | | | | | | 6. [PART OF PREVIOUS COMMENT #11.] OUTDOOR TRASH | | | CONTAINERS SHALL BE SCREENED IN ACCORDANCE WITH ZLDR | | | SEC. 94-444(C). PROVIDE DIMENSIONS ON THE DUMPSTER | | | ENCLOSURE AND DUMPSTER DETAIL IN ACCORDANCE WITH ZLDR | | | SEC. 94-444(B). THE MINIMUM REQUIRED DUMPSTER ENCLOSURE | | | SIZE IS 13?- 8? BY 13?- 8?. FINAL LOCATION OF DUMPSTER | | | TO BE APPROVED BY THE CITY?S ENGINEERING | | | DIVISION/PUBLIC UTILITIES DEPARTMENT. | | | | | | 7. DIMENSION PARKING SPACES AND DRIVE AISLES. FOR | | | ANGLED SPACES INCLUDE ANGLE OF THE PARKING. ONE PARKING | | | SPACES WILL NEED TO BE AN ADA COMPLIANT SPACE. PROVIDE | | | STRIPING DETAIL FOR BOTH STANDARD PARKING SPACE AND ADA | | | PARKING SPACE. | | | | | | 8. PROVIDE ONE BICYCLE PARKING SPACE PER 20 VEHICULAR | | | SPACES. PROVIDE RACK DETAIL, SPACING, AND PAD DETAIL. | | | | | | 9. FENCE LOCATED IN FRONT OF A BUILDING FA?ADE ALONG A | | | STREET IS LIMITED TO 42 INCHES IN HEIGHT [ZLDR SEC. | | | 94-221(D)(2)]. | | | | | | 10. INDICATE CORNER SITE TRIANGLES ON THE PLAN TO | | | DEMONSTRATE NO IMPROVEMENTS ABOVE 18 INCHES IN HEIGHT | | | ARE LOCATED WITHIN THIS AREA [ZLDR SEC. 94-305(E)]. | | | | | | 11. PHOTOMETRIC PLAN IS REQUIRED TO EVALUATE THE | | | PROPOSED ON-SITE LIGHTING FOR COMPLIANCE WITH ZLDR SEC. | | | 94-309(A) AND 94-310(D). | | | | | | 12. INCLUDE DUMPSTER AND VACUUM STAND SETBACKS FROM THE | | | PROPERTY LINE WHICH IS REQUIRED TO BE EVALUATED AS PART | | | OF THE ADDITIONAL SETBACK STANDARDS SETBACKS OF | | | STRUCTURES FROM THE PROPERTY LINE. DIMENSION IS | | | REQUIRED FOR THE WAIVER REQUEST. | | | | | | 13. PROVIDE A COMPLETE RESPONSE TO THE STANDARDS FOR | | | CODE COMPLIANCE (FULL LIST OF STANDARDS WILL BE SENT | | | OVER IN WORD FORMAT). IN ADDITION TO THE WAIVER REQUEST | | | TO ZLDR SEC. 94-273(D)(46)(B)(1) REGARDING DISTANCE OF | | | STRUCTURES FROM A RESIDENTIAL ZONING DISTRICT, THE PLAN | | | ALSO DOES NOT MEET ZLDR SEC. 94-273(D)(46)(B)(3)(IV) | | | REGARDING DISTANCE OF STRUCTURES FROM THE PUBLIC | | | RIGHT-OF-WAY LINES AND AN ADDITION FEE OF $270 IS | | | REQUIRED FOR THE ADDITIONAL WAIVER. PLEASE INCLUDE | | | DIMENSIONS OF BUILDINGS FROM THE RIGHT-OF-WAY LINES | | | INCLUDING DUMPSTER ENCLOSURE AND VACUUM STATIONS. | | | | | | 14. WHEN RESUBMITTING, PLEASE SUBMIT 10 PAPER COPIES | | | AND ELECTRONIC FILE OF THE PLANS. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
10-14-2015 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
10-14-2015 |
Time |
09:27 |
Rev Time |
|
| Received By |
dkittred |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-10-14 09:25:28 | PLANNING AND ZONING COMMENTS: | | | | | | 10/14/15 | | | | | | 1. SITE PLAN NEEDS TO DEPICT PROPOSED IMPROVEMENTS | | | VERSUS EXISTING CONDITIONS ON SITE PLAN. | | | | | | 2. SITE PLAN NEEDS TO ACCURATELY DEPICT SIDEWALKS. | | | PROPOSED PLAN SHOWS LANDSCAPING IN LOCATION OF EXISTING | | | SIDEWALK ALONG BROADWAY. ACCESS TO PUBLIC SIDEWALK WILL | | | NEED TO REMAIN. THERE IS ALSO A BUS STOP LOCATED ALONG | | | THE BROADWAY SIDE OF THE PROPERTY. | | | | | | 3. SITE PLAN INDICATES THE ENTIRE SITE IS CONCRETE. | | | SURVEY ONLY SHOWS CONCRETE WHERE CAR WASH BAYS ARE | | | LOCATED AND SOME ASPHALT LOCATED AROUND THE SOUTHERN | | | BUILDING. PLEASE CLARIFY ON SITE PLAN WHAT IS EXITING | | | AND WHERE NEW CONCRETE IS BEING PROPOSED. | | | | | | 4. DIMENSION DRIVE AISLE WIDTHS AND INDICATE IF NEW | | | CURB CUTS ARE PROPOSED OR EXISTING. | | | | | | 5. DEPICT PEDESTRIAN ACCESS TO THE SITE. | | | | | | 6. PROVIDE LAYOUT AND LOCATION OF ALL OFF-STREET | | | PARKING, LOADING, AND OTHER VEHICULAR USE AREAS | | | INCLUDING ADA PARKING SPACE. PROVIDE A PARKING | | | CALCULATION (ZLDR SEC. 94-221(F)(1)) AND STANDARD CITY | | | DETAIL FOR STRIPING PARKING SPACES. | | | | | | 7. LABEL ON SITE PLAN FENCE LOCATION VERSUS PROPERTY | | | LINE LOCATION AND ACCURATELY DEPICT LOCATION, TYPE, AND | | | HEIGHT OF FENCE AND INDICATE WHETHER THE FENCE IS | | | EXISTING OR PROPOSED. | | | | | | 8. INDICATE LAND USE AND ZONING OF THE SUBJECT | | | PROPERTY. THE SUBJECT PROPERTY HAS SPLIT LAND USE AND | | | ZONING WHICH NEEDS TO BE DEPICTED ON THE PLAN. | | | | | | 9. INDICATE ON SITE PLAN THE PROPOSED USE OF EACH | | | BUILDING AND SETBACKS. | | | | | | 10. LETTER FROM COMCAST INDICATES THERE IS AN EXISTING | | | EASEMENT AT THE REAR OF THE PROPERTY BETWEEN 56TH | | | STREET AND 57TH STREET, HOWEVER, THERE IS NO EASEMENT | | | SHOWN ON THE SURVEY. | | | | | | 11. HOW IS TRASH COLLECTION BEING HANDLED FOR THE SITE? | | | WILL THERE BE A DUMPSTER OR OTHER TRASH CONTAINERS? | | | OUTDOOR TRASH CONTAINERS SHALL BE SCREEN IN ACCORDANCE | | | WITH ZLDR SEC. 94-444(C). PLEASE DEMONSTRATE | | | COMPLIANCE. | | | | | | 12. IS THIS A SELF-SERVICE CAR WASH OR FULL-SERVICE CAR | | | WASH? IF SELF-SERVICE, WILL THERE BE AN ATTENDANT | | | PRESENT DURING HOURS OF OPERATION? WHAT ARE THE | | | PROPOSED HOURS OF OPERATION? PLEASE EXPLAIN OPERATION. | | | | | | 13. IF ONLY ENTRANCE IS FROM 56TH STREET INDICATE HOW | | | STACKING WILL BE HANDLED SO VEHICLES DO NOT BACK-UP ON | | | TO BROADWAY. | | | | | | 14. WILL ANY NEW LIGHTING BE ADDED TO THE SITE? IF YES, | | | PROVIDE LOCATION, HEIGHT, AND INTENSITY OF ALL OUTDOOR | | | ILLUMINATION. | | | | | | 15. WILL THERE BE RETAIL SALES ON THE SITE? IF YES, | | | INDICATE WHERE AND SQUARE FOOTAGE OF THE SPACE. | | | | | | 16. ARE ANY TYPES OF BUILDING IMPROVEMENTS BEING | | | PROPOSED? | | | | | | 17. PLEASE PROVIDE A WRITTEN RESPONSE TO ALL ADDITIONAL | | | STANDARDS IN ZLDR SEC. 94-273(D)(46). THERE ARE 12 | | | STANDARDS AND ONLY 1 THRU 3 WERE ADDRESSED DIRECTLY ON | | | THE SITE PLAN. | | | | | | 18. PLEASE NOTE THE SITE DOES NOT COMPLY WITH ITEM 1 AS | | | INDICATED. THE BUILDINGS ARE LOCATED AS CLOSE AS 15.07 | | | FEET FROM A RESIDENTIAL ZONING DISTRICT AND 100 FEET IS | | | REQUIRED. A WAIVER HAS BEEN REQUESTED. | | | | | | 19. THE SITE ALSO DOES NOT COMPLY WITH SUBSECTION 3.IV. | | | WHICH REQUIRES BUILDINGS TO BE LOCATED A MINIMUM OF 25 | | | FEET FROM A RIGHT-OF-WAY. A WAIVER REQUEST WILL BE | | | REQUIRED. | | | | | | 20. IT DOES NOT APPEAR THE APPLICATION COMPLIES WITH | | | SUBSECTION 8, REQUIRING AN OPAQUE FENCE NEXT TO A | | | RESIDENTIAL ZONING DISTRICT. PLEASE DEMONSTRATE | | | COMPLIANCE. | | | | | | 21. APPLICATION SHOULD INDICATE WHAT TYPE OF MITIGATION | | | IS PROPOSED FOR WAIVER REQUESTS TO REDUCE THE IMPACT OF | | | THE CAR WASH ON THE ADJACENT RESIDENTIAL AREA. OTHER | | | SITE IMPROVEMENTS, SUCH AS REMOVAL OF THE CHAIN-LINK | | | FENCE ALONG STREET FRONTAGES WHICH IS NOT PERMITTED, TO | | | BRING THE SITE CLOSER INTO COMPLIANCE WITH THE CURRENT | | | CODE SHOULD BE REVIEWED AS PART OF THE PROPOSAL. | | | | | | 22. IN AN OVERALL REVIEW OF THE REQUEST SUBMITTED, | | | STAFF'S SUPPORT FOR A RECOMMENDATION OF APPROVAL IS NOT | | | EXPECTED. | | | | | | 23. IN ORDER TO BE CONSIDERED FOR THE NOVEMBER 5, 2015 | | | ZONING BOARD OF APPEALS MEETING, COMPLETE REVISED PLANS | | | MUST BE SUBMITTED NO LATER THAN OCT. 22, 2015. PLEASE | | | NOTE, THAT SUBMITTAL OF THE REQUESTED | | | INFORMATION/REVISIONS MAY GENERATE ADDITIONAL COMMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
| |
Print |