Plan Review Details - Project Z15090018
Plan Review Stops For Project Z15090018
Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 01-19-2016 Cont ID  
Sent By eschneid Date 01-19-2016 Time 14:38 Rev Time 0.00
Received By eschneid Date 01-19-2016 Time 14:38 Sent To  
Notes
2016-01-19 14:38:38FINAL REVIEW TO OCCUR AT BUILDING PERMIT.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 09-24-2015 Cont ID  
Sent By wjolin Date 09-24-2015 Time 16:55 Rev Time 0.00
Received By wjolin Date 09-24-2015 Time 15:32 Sent To  
Notes
2015-09-24 15:41:56600 OKEECHOBEE BOULEVARD
 PERMIT #Z15090018
 MASTER #14050111
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 THE EXIT DISCHARGE AND PUBLIC WAY HAVE BEEN MODIFIED
 FROM THE ORIGINAL PERMITTED DESIGN; THEREFORE, A
 SIGNED/SEALED REVISED LIFE SAFETY PLAN IS NEEDED FROM
 THE ARCHITECT. THE LIFE SAFETY PLAN (SHEET A2.02 FROM
 PERMIT #14050111) INDICATES A POTENTIAL EXITING
 OCCUPANT LOAD OF 1060 PERSONS (320 POOL, 400 JR
 BALLROOM, 340 SERVICE CORRIDOR) ADJACENT TO THE NEWLY
 PROPOSED EXTERIOR STAIR. THE PLAN INDICATES THE STAIR
 IS 15'-3" WIDE; HOWEVER, TO ACCOMMODATE AN OCCUPANT
 LOAD OF 1060 PERSONS, THE STAIRS WOULD NEED TO BE
 26'-6" WIDE (1060 X 0.3 INCHES PER PERSON = 318 INCHES)
 TO AVOID EGRESS STALL. ADDITIONALLY, A POTENTIAL
 EXITING OCCUPANT LOAD OF 1093 PERSONS (652 & 441
 BALLROOMS) EXISTS AT THE 3 SETS OF EXIT DOORS ADJACENT
 (WEST) OF THE LOADING DOCK. DUE TO THE PROPOSED
 LANDSCAPING AND 11 FOOT-HIGH PERIMETER WALL LOCATION,
 THESE 1093 OCCUPANTS WOULD BE FORCED TO TRAVEL THROUGH
 AN UNFAMILIAR HIGHER HAZARD OCCUPANCY (LOADING
 DOCK/STORAGE) TO REACH THE PUBLIC WAY POINT OF SAFETY.
 TRAVEL THROUGH A HIGHER HAZARD OCCUPANCY CLASSIFICATION
 (ASSEMBLY TO STORAGE) IS NOT PERMITTED BY SECTION
 7.5.1.6 OF THE FLORIDA FIRE PREVENTION CODE (NFPA 101).
  
 THE ROAD AND SIDEWALK (AKA "PUBLIC WAY") BETWEEN THE
 CONVENTION CENTER, CONVENTION CENTER GARAGE "TO BE" AND
 THE HILTON HOTEL IS CURRENTLY A DIRT CONSTRUCTION SITE
 ENVELOPED BY CONSTRUCTION FENCING. FIRE EXIT DISCHARGE
 IS REQUIRED TO LEAD TO A PUBLIC WAY; THEREFORE, THE
 PUBLIC WAY NEEDS TO BE COMPLETED TO ALLOW OCCUPANCY OF
 THE HILTON BUILDING.
  
 THE CONVENTION CENTER CULDESAC AND ROAD LEADING FROM
 FLORIDA AVENUE IS A FIRE DEPARTMENT ACCESS ROAD AND
 NEEDS "NO PARKING - FIRE LANE" SIGNAGE AND ROAD
 MARKINGS AS INDICATED ON SHEET C3.03 OF PERMIT
 #14050111.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop Z ZONING
Rev No 4 Status F Date 03-28-2017 Cont ID  
Sent By eschneid Date 03-28-2017 Time 09:53 Rev Time 0.50
Received By eschneid Date 03-28-2017 Time 09:53 Sent To  
Notes
2017-03-28 09:54:18CASE NO. PB 950SSSS
 HILTON CONVENTION CENTER HOTEL LOADING AREA - C.O.
 REVIEW
 600 OKEECHOBEE BOULEVARD
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR
 (4) FULL SIZED PAPER COPIES AND AN ELECTRONIC COPY IN
 .PDF FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON
 THE RESUBMITTED PLANS OR THE SUBMITTAL OF
 INFORMATION/PLANS TO ADDRESS THE COMMENTS MAY RESULT IN
 ADDITIONAL COMMENTS.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 ADDITIONAL RESUBMITTAL AT NO ADDITIONAL COST. IF
 PREVIOUSLY-ISSUED COMMENTS CONTINUE TO NOT BE
 SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE ACCESSED
 A RESUBMITTAL FEE. SUCH FEE WILL BE 20% OF THE ORIGINAL
 APPLICATION FEE ($60).
  
 1) THE WALL PORTION OF THIS APPLICATION IS STILL
 OUTSTANDING AND IS PREVENTING THE APPROVAL OF THE MINOR
 AMENDMENT.
  
 2) THE BUILDING PERMIT FOR THE CMU WALL (15080551) IS
 SHOWN AS EXPIRED IN THE CITY'S RECORDS. THIS PERMIT
 NEEDS TO BE ACTIVATED, REVIEWED, APPROVED AND THE
 INSPECTIONS PASSED FOR THE WALL.
  
 3) REPEAT COMMENT: THE PLANS SUBMITTED TO DATE FOR THE
 MINOR AMENDMENT AND THE PERMIT DO NOT MATCH. THERE ARE
 VARIOUS CONFLICTING WALL HEIGHTS SHOWN RANGING FROM SIX
 (6) FEET IN HEIGHT TO 11 FEET IN HEIGHT. ALL PLANS
 SHALL MATCH AND SHOW THE FINAL WALL CONFIGURATION.
  

Review Stop Z ZONING
Rev No 3 Status F Date 09-07-2016 Cont ID  
Sent By eschneid Date 09-07-2016 Time 14:11 Rev Time 1.00
Received By eschneid Date 09-07-2016 Time 14:11 Sent To  
Notes
2016-09-07 14:12:02CASE NO. PB 950SSSS
 HILTON CONVENTION CENTER HOTEL LOADING AREA -
 RESUBMITTAL
 600 OKEECHOBEE BOULEVARD
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR
 (4) FULL SIZED PAPER COPIES AND AN ELECTRONIC COPY IN
 .PDF FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON
 THE RESUBMITTED PLANS OR THE SUBMITTAL OF
 INFORMATION/PLANS TO ADDRESS THE COMMENTS MAY RESULT IN
 ADDITIONAL COMMENTS.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 ADDITIONAL RESUBMITTAL AT NO ADDITIONAL COST. IF
 PREVIOUSLY-ISSUED COMMENTS CONTINUE TO NOT BE
 SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE ACCESSED
 A RESUBMITTAL FEE. SUCH FEE WILL BE 20% OF THE ORIGINAL
 APPLICATION FEE ($60).
  
 1) THANK YOU FOR PROVIDING THE TURNING RADIUS EXHIBIT
 FOR THE WB-50 TRUCK. THE EXHIBIT VERIFIES THAT THIS
 TRUCK IS UNABLE TO EXIT THE MIDDLE LOADING BAY ONTO
 FLORIDA AVENUE IF A SWING GATE IS USED. THE TRAILER
 WILL HIT THE OPEN GATE LEAVING THE SITE. PLEASE NOTE
 THAT SECTION 94-111(M) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS PROHIBITS THE USE OF PUBLIC
 RIGHTS-OF-WAY FOR MANEUVERING ASSOCIATED WITH BUILDING
 LOADING AREAS, SO BACKING INTO THE STREET (REVERSING
 THE ENTRY MOVEMENT) IS NOT PERMITTED. THIS IS NOT AN
 ISSUE WITH THE CURRENTLY APPROVED GATE ARMS. ZONING
 STAFF WILL NOT APPROVE SWING GATES.
  
 2) THE TURNING RADIUS EXHIBIT SHOWS THE GARBAGE TRUCK
 USING THE WESTERN LOADING SPACE AS MANEUVERING FOR TO
 TURN AROUND TO LEAVE THE SITE TO AVOID HITTING AN OPEN
 SWING GATE. HOW WILL THE TURNAROUND BE ACHIEVED IF
 THERE ARE TRUCKS PARKED IN THE LOADING ZONES? THIS IS
 NOT AN ISSUE WITH THE CURRENTLY APPROVED GATE ARMS.
  
 3) REPEAT COMMENT: THE PLANS SHALL INCLUDE A SHEET TO
 REFLECT THE REVISED MEDIANS AND THE PEDESTRIAN CROSSING
 THAT ARE INCLUDED WITH THE APPROVED CONVENTION CENTER
 GARAGE PLAN. THIS INCLUDES FLORIDA AVENUE AND THE
 CONVENTION CENTER ENTRY DRIVE CROSSING FOR THE GARAGE
 DISCHARGE. PROVIDE THE TURNING RADIUS PLANS TO SHOW THE
 TRUCKS ENTERING AND LEAVING THE LOADING AREA WITH THE
 NEW CONFIGURATION. THE LATEST PLANS SUBMITTED TO THE
 CITY FAIL TO SHOW THE FINAL CONFIGURATION OF THE
 MEDIANS AS SHOWN ON THE PARKING GARAGE APPROVED PLANS,
 BUT RATHER SHOW ONLY THE GHOSTED ADDITION OF THE
 PEDESTRIAN CROSSING MEDIAN. THE TURNING MOVEMENTS SHOW
 TRUCKS HITTING THIS MEDIAN.
  
 4) REPEAT COMMENT: THE SIDEWALK SOUTH OF THE WALL SHALL
 BE ILLUMINATED FOR SAFETY WITH LIGHT FIXTURES THAT
 MATCH THOSE USED FOR THE HOTEL. THIS MAY REQUIRE
 MOUNTING LIGHTING TO THE WALL. THE SHEET THAT WAS
 SUBMITTED TO SHOW THE LOCATIONS OF THE GARAGE LIGHTING
 FAILS TO SHOW THAT THE SIDEWALK WILL BE SAFELY
 ILLUMINATED.
  
 5) REPEAT COMMENT: THE ENGINEER STAMPED DRAWING WITH
 THE BUILDING PERMIT SHOW THE WALL AT TEN FEET IN HEIGHT
 WHILE SHEET LS503 LD SHOWS THE WALL AT 11 FEET IN
 HEIGHT. ALL PLANS SHALL SHOW THE SAME WALL HEIGHT.
  

Review Stop Z ZONING
Rev No 2 Status F Date 01-19-2016 Cont ID  
Sent By eschneid Date 01-19-2016 Time 14:40 Rev Time 0.50
Received By eschneid Date 01-19-2016 Time 14:40 Sent To  
Notes
2016-01-19 15:10:49CASE NO. PB 950SSSS
 HILTON CONVENTION CENTER HOTEL LOADING AREA ? 1ST
 RESUBMITTAL 11/17/15
 600 OKEECHOBEE BOULEVARD
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FIVE
 (5) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 ADDITIONAL RESUBMITTAL AT NO ADDITIONAL COST. IF
 PREVIOUSLY-ISSUED COMMENTS CONTINUE TO NOT BE
 SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE ACCESSED
 A RESUBMITTAL FEE. SUCH FEE WILL BE 20% OF THE ORIGINAL
 APPLICATION FEE ($60).
  
 1) REPEAT COMMENT: THE PLANS SHALL INCLUDE A SHEET TO
 REFLECT THE REVISED MEDIANS AND THE PEDESTRIAN CROSSING
 THAT ARE INCLUDED WITH THE APPROVED CONVENTION CENTER
 GARAGE PLAN. THIS INCLUDES FLORIDA AVENUE AND THE
 CONVENTION CENTER ENTRY DRIVE CROSSING FOR THE GARAGE
 DISCHARGE. PROVIDE THE TURNING RADIUS PLANS TO SHOW THE
 TRUCKS ENTERING AND LEAVING THE LOADING AREA WITH THE
 NEW CONFIGURATION.
  
 2) REPEAT COMMENT: THE SIDEWALK SOUTH OF THE WALL SHALL
 BE ILLUMINATED FOR SAFETY WITH LIGHT FIXTURES THAT
 MATCH THOSE USED FOR THE HOTEL. THIS MAY REQUIRE
 MOUNTING LIGHTING TO THE WALL.
  
 3) REPEAT COMMENT: THE VARIOUS PLANS (INCLUDING THE
 SUBMITTED BUILDING PERMIT) SHOW THE WALL HEIGHT RANGING
 FROM SIX (6) FEET TALL TO ELEVEN (11) FEET TALL. THE
 ENGINEER STAMPED DRAWING WITH THE BUILDING PERMIT SHOW
 THE WALL AT TEN FEET IN HEIGHT. WHILE PLANNING STAFF
 DOES NOT THINK THAT A WALL OF ANY HEIGHT IS APPROPRIATE
 AT THIS LOCATION, PLANNING STAFF PREFERS A SIX (6) FOOT
 TALL WALL TO THE OTHER OPTIONS SHOWN ON THE CONFLICTING
 PLANS. ALL PLANS SHALL SHOW THE SAME WALL HEIGHT.
  

Review Stop Z ZONING
Rev No 1 Status F Date 10-23-2015 Cont ID  
Sent By eschneid Date 10-23-2015 Time 16:36 Rev Time 0.00
Received By eschneid Date 10-23-2015 Time 16:36 Sent To  
Notes
2015-10-23 16:37:11CASE NO. PB 950SSSS
 HILTON CONVENTION CENTER HOTEL LOADING AREA
 600 OKEECHOBEE BOULEVARD
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FIVE
 (5) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($60).
  
 1) THE PLANS SHALL BE REVISED TO ADDRESS THE FIRE
 DEPARTMENT EMERGENCY EGRESS CONCERNS.
  
 2) PROVIDE INFORMATION TO SHOW WHERE THE REQUIRED TEN
 BUFFER TREES BETWEEN THE HOTEL AND THE CONVENTION
 CENTER WILL BE PLACED BASED ON THE REVISIONS TO ADDRESS
 THE FIRE DEPARTMENT COMMENTS. ADDITIONALLY, A TABLE
 SHALL BE PROVIDED TO VERIFY THAT THERE IS NO NET LOSS
 OF TREES FOR THE OVERALL HOTEL SITE BASED ON THE
 REVISED LOADING AREA.
  
 3) THE APPROVED PLANS SHOW THREE MONTGOMERY PALMS
 BETWEEN THE HOTEL AND THE CONVENTION CENTER AT THE
 SOUTHWEST CORNER OF THE HOTEL SITE. THESE ARE NOT
 REFLECTED ON THE CURRENT LANDSCAPE PLAN. WHAT IS THE
 STATUS OF THESE PALMS?
  
 4) THE CIVIL PLANS SHALL BE UPDATED TO REFLECT THE GATE
 ARMS MOVED CLOSER TO THE INTERSECTION AS SHOWN ON THE
 HARDSCAPE AND LANDSCAPE PLANS.
  
 5) THE PLANS SHALL BE UPDATED TO REFLECT THE REVISED
 MEDIANS AND THE PEDESTRIAN CROSSING THAT ARE INCLUDED
 WITH THE APPROVED CONVENTION CENTER GARAGE PLAN. THIS
 INCLUDES FLORIDA AVENUE AND THE CONVENTION CENTER ENTRY
 DRIVE CROSSING FOR THE GARAGE DISCHARGE.
  
 6) THERE SHALL BE LIGHTING THAT MATCHES THE LIGHT
 FIXTURES FOR THE HOTEL PROVIDED ALONG THE SIDE WALK.
  
 7) THE VARIOUS PLANS (INCLUDING THE SUBMITTED BUILDING
 PERMIT) SHOW THE WALL HEIGHT RANGING FROM SIX (6) FEET
 TALL TO ELEVEN (11) FEET TALL. WHILE PLANNING STAFF
 DOES NOT THINK THAT A WALL OF ANY HEIGHT IS APPROPRIATE
 AT THIS LOCATION, PLANNING STAFF PREFERS A SIX (6) FOOT
 TALL WALL TO THE OTHER OPTIONS SHOWN ON THE CONFLICTING
 PLANS. ALL PLANS SHALL SHOW THE SAME WALL HEIGHT.
  