Plan Review Details - Project Z15040045
| Plan Review Stops For Project Z15040045 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
05-12-2015 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
05-12-2015 |
Time |
21:14 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
05-12-2015 |
Time |
21:14 |
Sent To |
|
|
| Notes |
| 2015-05-12 21:28:15 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. THE PCC CLUBHOUSE FLOOR PLAN SHOWS TO EXIT DOORS | | | FROM THE BUILDING. SITE PLAN, SHEET SP-1, SHOWS SOD | | | IMMEDIATELY OUTSIDE THE "REAR" DOOR. SHOW AT LEAST ONE | | | ACCESSIBLE ROUTE, COMPLYING WITH SECTIONS 207, 206.2 | | | AND 402.2 OF FLORIDA ACCESSIBILITY CODE, CONNECTING THE | | | EXIT DOOR TO THE SIDEWALK IN FRONT OF THE BUILDING. | | | | | | 3. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 4. EACH SEPARATE BUILDING SHALL HAVE AN SEPARATE | | | ADDRESS. FOR STREET ADDRESSING, CONTACT MICHAEL ORIO, | | | GIS SUPPORT SPECIALIST, AT (561) 494 1080, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
05-08-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
05-08-2015 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
05-08-2015 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2015-05-08 13:53:58 | CITY OF WEST PALM BEACH | | | PUBLIC WORKS DEPARTMENT | | | | | | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE | | | PLAN APPROVAL. | | | | | | 1. PLEASE CLARIFY THE PURPOSE OF THE FOOD TRAILER. WILL | | | FOOD BE PREPARED IN THE TRAILER? ARE WATER AND SEWER | | | CONNECTIONS PROPOSED FOR THE TRAILER? | | | | | | 2. PLEASE SHOW THE LOCATION OF THE PROPOSED COVERED | | | OUTDOOR SEATING AREA. | | | | | | 3. THE PROPOSED DUMPSTER LOCATION WILL REQUIRE THE | | | SANITATION TRUCK TO CROSS A PORTION OF THE PROPOSED | | | SIDEWALK. BASED ON THE CURB CUT RAMP PROPOSED ADJACENT | | | TO THE DUMPSTER ACCESS DRIVE, THIS PORTION OF THE | | | SIDEWALK WILL NOT BE FLUSH WITH THE ADJACENT PAVEMENT. | | | PLEASE DEMONSTRATE THAT THE DUMPSTER WILL BE LOCATED IN | | | AREAS EASILY SERVICED BY THE CITY SANITATION EQUIPMENT | | | AND MANPOWER. [SECTION 74-35(A)(5) OF THE CODE OF | | | ORDINANCES] | | | | | | 4. PLEASE VERIFY THAT THE TRUCK ROUTE TO THE DUMPSTER | | | ENCLOSURE CAN WITHSTAND THE HEAVY LOADING OF THE FILLED | | | SANITATION TRUCK. THE TRUCKS ARE RATED FOR 15,000 LBS | | | PER AXLE. | | | | | | 5. THE SHOWN TRAFFIC PATTERN AND SIGNAGE AT THE BAG | | | DROP OFF LOCATION. CONSIDER UTILIZING A CONFIGURATION | | | AND SIGNING SIMILAR TO A ROUND-ABOUT OR EXPANDING THE | | | BAD DROP OFF TO INCLUDE A BY-PASS LANE RATHER THAN | | | HAVING TRAFFIC TRAVEL SOUTH BOUND ON BOTH SIDES OF THE | | | ISLAND. IF THE EXISTING CONFIGURATION IS TO BE | | | UTILIZED, DESIGNATE WHICH OF THE SOUTH BOUND LANES MUST | | | YIELD OR STOP. | | | | | | 6. THE PROPOSED TRAFFIC SIGNS SHOWN ON SHEET SP-1 ARE | | | DO NOT MEET THE STANDARDS SPECIFIED IN THE MANUAL OF | | | UNIFORM TRAFFIC CONTROL DEVICES. PLEASE CONSIDER | | | UTILIZING SIGNAGE WHICH IS CONSISTENT WITH THE MUTCD | | | SUCH AS R3-1 (NO RIGHT TURN SYMBOL ONLY) OR R5-1 (DO | | | NOT ENTER). TYPICALLY, ONLY ONE OF THE TWO SIGNS IS | | | UTILIZED TO CONTROL A SPECIFIC TRAFFIC MOVEMENT. | | | | | | THE FOLLOWING COMMENTS MUST BE ADDRESSED IN THE PRIOR | | | TO ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING | | | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. | | | | | | 1. AS SEPARATE SUBMITTAL WILL BE REQUIRED TO THE | | | ENGINEERING DIVISION OF THE PUBLIC WORKS DEPARTMENT. | | | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS | | | CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 2. SOLID WASTE YARDAGE WILL NEED TO BE ESTIMATED AS | | | PART OF THE FINAL DESIGN TO VERIFY THAT THE DESIGN | | | INCLUDES APPROPRIATE NUMBER AND SIZE OF TRASH BINS. | | | | | | KELLY CRANFORD, P.E. | | | LAND DEVELOPMENT ENGINEER | | | [email protected] | | | 561-494-1098 (OFFICE) | | | | | | VINCE NOEL, PSM | | | CITY SURVEYOR / REAL ESTATE SUPERVISOR | | | [email protected] | | | 561-494-1096 | | | | | | BRIAN COLLINS, PE | | | CITY TRAFFIC ENGINEER | | | [email protected] | | | 561-494-1040 | | | | | | FERDINAND RIVERA | | | PUBLIC WORKS OPERATIONS MANAGER | | | [email protected] | | | 561-822-2076 | | | | | | TRACY WARD, PE | | | CITY STORMWATER ENGINEER | | | 561-494-1120 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
06-04-2015 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
06-04-2015 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
06-04-2015 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2015-06-04 12:00:32 | AFTER A REVIEW OF THE PPRC RESPONSE LETTER DATED MAY | | | 27, 2015, FROM URBAN DESIGN KILDAY STUDIOS, TO JOHN | | | ROACH, PRINCIPAL PLANNER, THE PREVIOUSLY SUBMITTED FIRE | | | PREVENTION BUREAU COMMENTS HAVE BEEN ADDRESSED. | | | | | | THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES | | | NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
05-06-2015 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
05-06-2015 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
05-06-2015 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2015-05-06 14:39:58 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE | | | PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS. A | | | PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER RELATED | | | TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN | | | STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY | | | MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER | | | PROTECTION. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE | | | REMOVED FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE | | | ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION SHALL COMPLY WITH THE NFPA 1, FIRE | | | CODE, 2012 EDITION; FLORIDA FIRE PREVENTION CODE, 2012 | | | EDITION. | | | | | | 6. EACH BUILDING/TENT OCCUPANY SHALL BE IDENTIFIED AND | | | SHALL COMPLY WITH THE APPLICABLE CODE SECTIONS OF THE | | | FLORIDA FIRE PREVENTION CODE AS A "NEW" OCCUPANY. A | | | "TEMPORAY" OCCUPANY CLASSIFICATION SHALL NOT BE | | | APPROVED. | | | | | | 7. WHERE REQUIRED OF THE NEW OCCUPANCY A FIRE SPRINKLER | | | OR FIRE ALARM SHALL BE INSTALLED. | | | | | | 8. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 9. ALL FIRE WATER MAINS, SIZES, VALVE ASSEMBLIES AND | | | FIRE HYDRANTS SHALL BE CLEARLY IDENTIFIED AND | | | ILLUSTRATED ON THE PLAN. | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
05-12-2015 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
05-12-2015 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
05-12-2015 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2015-05-12 16:39:19 | 1. PLEASE PROVIDE A TREE SURVEY IDENTIFYING EXISTING | | | TREES ON THE PROPERTY AND INDICATE THE SPECIES, SIZE, | | | AND IF THEY WILL BE REMOVED, RELOCATED, OR REMAIN. | | | THERE ARE SEVERAL PINK TABEBUIA TREES AND COCONUT PALMS | | | ALONG THE WEST PROPERTY LINE NOT SHOWN ON THE LANDSCAPE | | | PLAN. THERE IS A SABAL PALM IN THE PARKING LOT ISLAND | | | AND SEVERAL COCONUT PALM GROUPINGS IN THE CENTER OF THE | | | SITE NOT SHOWN ON THE PLAN. | | | | | | CONDITIONS OF APPROVAL | | | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT | | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | | | RAY CARANCI, LANDSCAPE PLANNER | | | 561-822-1462 |
|
|
| Review Stop |
PARK |
PARKING |
| Rev No |
1 |
Status |
P |
Date |
05-12-2015 |
|
|
Cont ID |
|
| Sent By |
ssamuels |
Date |
05-12-2015 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
ssamuels |
Date |
05-12-2015 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
05-08-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
05-08-2015 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
05-08-2015 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2015-05-08 13:54:28 | SEE COMMENTS UNDER PPRC ENGINEERING |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
P |
Date |
05-08-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
05-08-2015 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
05-08-2015 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2015-05-08 13:54:51 | SEE COMMENTS UNDER PPRC ENGINEERING |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
P |
Date |
05-08-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
05-08-2015 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
05-08-2015 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2015-05-08 13:55:11 | SEE COMMENTS UNDER PPRC ENGINEERING |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
05-08-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
05-08-2015 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
05-08-2015 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2015-05-08 13:55:50 | SEE COMMENTS UNDER PPRC ENGINEERING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
05-13-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
05-13-2015 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
05-13-2015 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2015-05-13 11:49:42 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 05.13.2015 | | | PROJECT NO.: Z15040045 | | | CASE NO.: PB 1624I | | | ADDRESS: 2300 PRESIDENTIAL WAY | | | APPLICANT/CONTACT: JONI BRINKMAN | | | TELEPHONE NO.: 561.366.1100 | | | SCOPE OF REVIEW: TEMPORARY CLUBHOUSE. | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. THE TRAFFIC CONCURRENCY LETTER SUBMITTED WITH THE | | | APPLICATION IS NOT THE MOST RECENT. | | | | | | 2. THE SITE/LANDSCAPE PLAN IS SHOWING A TREE TO BE | | | INSTALLED IN THE CART STAGING AREA, WHICH IS PROPOSED | | | TO BE A ROCK SURFACE. PLEASE CLARIFY. | | | | | | 3. IS THE FENCE PROPOSED TO EXTEND ACROSS THE 12 FOOT | | | DRAINAGE EASEMENT? IT IS RECOMMEND THAT THIS FENCE BE | | | CONTINUOUS AND THAT EASEMENT CONSENT BE OBTAINED FROM | | | THE EASEMENT HOLDER. | | | | | | 4. PLEASE NOTE THE CONDITIONS OF APPROVAL THAT WERE | | | ISSUED ORIGINALLY (DECEMBER 20, 2013). | | | ___________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 6 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
| |
Print |
|
Account Summary | Usage Policy | Privacy Policy