Plan Review Details - Project Z15030022
| Plan Review Stops For Project Z15030022 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
04-27-2015 |
|
|
Cont ID |
|
| Sent By |
|
Date |
04-27-2015 |
Time |
|
Rev Time |
0.00 |
| Received By |
jroach |
Date |
04-27-2015 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2015-10-02 13:02:20 | PURSUANT TO AN EMAIL SENT TO ALL PLAN REVIEWERS ON | | | 4/21/2015, ALL OUTSTANDING COMMENTS WERE TO BE INSERTED | | | INTO COMMUNITYPLUS BEFORE THE END OF THE DAY ON | | | 4/27/2105. IF COMMENTS WERE NOT INSERTED PRIOR TO THAT | | | TIME, IT WAS TO BE ASSUMED THAT ALL COMMENTS HAD BEEN | | | SATISFACTORILY ADDRESSED. NO COMMENTS WERE RECEIVED FOR | | | THIS REVIEW, SO THE STATUS HAS BEEN SET AS ?PASSED?. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
04-08-2015 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
04-08-2015 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
04-08-2015 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2015-04-08 10:49:29 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. SHEET C2 DOES NOT SHOW ANY ACCESIBLE ROUTE FROM THE | | | PUBLIC SIDEWALK TO THE TWO RETAIL ENTRANCES. WHEN | | | SUBMITTED FOR PERMIT, THE PLANS SHALL SHOW AT LEAST ONE | | | ACCESSIBLE ROUTE, COMPLYING WITH SECTIONS 206.2 AND | | | 402.2 OF FLORIDA ACCESSIBILITY CODE, FROM THE PUBLIC | | | RIGHT-OF-WAY TO ALL ACCESSIBLE BUILDING OR FACILITY | | | ENTRANCES. | | | | | | 3. SHEET C2 SHOWS MORE THAN 50 PARKING SPACES SERVING | | | THE TWO PROPOSED BUSINESSES. PER SECTION 208.2 AND | | | 208.3 OF FLORIDA ACCESSIBILITY CODE AT LEAST 3 | | | ACCESSIBLE PARKING SPACES ARE TO BE PROVIDED AS THE | | | PARKING SPACES NEAREST TO THE TWO ENTRANCES. ACCESSIBLE | | | PARKING SPACES ARE TO BE LOCATED ON THE SHORTEST | | | POSSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING TO AN | | | ACCESSIBLE ENTRANCE FOR EACH BUILDING. THE DESIGN OF | | | ACCESSIBLE PARKING SPACES SHALL COMPLY WITH SECTION 502 | | | OF FLORIDA ACCESSIBILITY CODE. | | | | | | 4. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL | | | SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS | | | WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND | | | OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA | | | BUILDING CODE | | | | | | 5. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH | | | ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND | | | OPENING PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 OF | | | THE FLORIDA BUILDING CODE SHALL BE VERIFIED. | | | | | | 6. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, | | | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND | | | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, | | | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 7. FOR STREET ADDRESSING, CONTACT MICHAEL ORIO, GIS | | | SUPPORT SPECIALIST, AT (561) 494 1080, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
04-27-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
04-27-2015 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
04-27-2015 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2015-10-02 13:03:09 | PURSUANT TO AN EMAIL SENT TO ALL PLAN REVIEWERS ON | | | 4/21/2015, ALL OUTSTANDING COMMENTS WERE TO BE INSERTED | | | INTO COMMUNITYPLUS BEFORE THE END OF THE DAY ON | | | 4/27/2105. IF COMMENTS WERE NOT INSERTED PRIOR TO THAT | | | TIME, IT WAS TO BE ASSUMED THAT ALL COMMENTS HAD BEEN | | | SATISFACTORILY ADDRESSED. NO COMMENTS WERE RECEIVED FOR | | | THIS REVIEW, SO THE STATUS HAS BEEN SET AS ?PASSED?. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
04-06-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
04-06-2015 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
04-06-2015 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2015-04-06 15:51:58 | PUBLIC WORKS DEPT. | | | | | | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 1. PLEASE CLARIFY WHICH VERTICAL DATUM HAS BEEN USED | | | FOR THE PLANS. SECTION 78-9 OF THE CITY?S CODE OF | | | ORDINANCES SPECIFIES NGVD 1929 AS THE OFFICIAL CITY | | | VERTICAL DATUM. | | | | | | 2. PLEASE SUBMIT ESTIMATES FOR THE PEAK POTABLE WATER | | | DEMAND, SANITARY SEWER FLOW, AND SOLID WASTE COLLECTION | | | YARDAGE. | | | | | | 3. PLEASE DEMONSTRATE THE PROPOSED STRIPING WILL COMPLY | | | WITH CITY OF WEST PALM BEACH CODE OF ORDINANCES, | | | ARTICLE XV, SECTION 94-485. | | | | | | 4. THE PROPOSED DUMPSTER LOCATION APPEARS TO BE OUTSIDE | | | OF THE LEASE AREA SHOWN ON THE SUBMITED SURVEY. IS | | | THERE A SEPARATE AGREEMENT WITH THE PROPERTY OWNER | | | ALLOWING THE CONSTRUCTION OF THE DUMPSTER ENCLOSURE AND | | | REVISIONS TO THE LANDSCAPED AREA? | | | | | | 5. PLEASE PROVIDE A COPY OF THE PHOTOMETRIC PLAN | | | DEMONSTRATING THE PROPOSED DESIGN MEETS THE | | | REQUIREMENTS OF CITY ORDINANCE 94-309 AND 94-113. | | | | | | 6. PLEASE PROVIDE POLLUTANT CONTROL BAFFLES IN | | | STORMWATER INLETS NEAR THE PROPOSED GAS ISLANDS. | | | | | | 7. PLEASE VERIFY COMPLIANCE WITH ADA ACCESSIBLE ROUTE | | | WIDTH REQUIREMENTS IN AREAS OF SIDEWALK WHERE VENDOR | | | MACHINES (I.E. REDBOX, ICE) ARE PROPOSED. | | | | | | A RIGHT-OF-WAY PERMIT FROM THE ENGINEERING DEPARTMENT | | | WILL BE REQUIRED FOR ALL WORK WITHIN THE CITY OF WEST | | | PALM BEACH RIGHT-OF-WAY. THE APPLICATION FORM AND | | | CONSTRUCTION STANDARDS CAN BE FOUND AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | | | | KELLY CRANFORD, PE | | | CITY LAND DEVELOPMENT ENGINEER | | | [email protected] | | | 561-494-1098 (OFFICE) | | | | | | VINCE NOEL, PSM | | | CITY SURVEYOR / REAL ESTATE SUPERVISOR | | | [email protected] | | | 561-494-1096 | | | | | | BRIAN COLLINS, PE | | | CITY TRAFFIC ENGINEER | | | [email protected] | | | 561-494-1040 | | | | | | FERDINAND RIVERA | | | PUBLIC WORKS OPERATIONS MANAGER | | | [email protected] | | | 561-822-2076 | | | | | | TRACY WARD, PE | | | CITY STORMWATER ENGINEER | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
04-24-2015 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
04-24-2015 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
04-24-2015 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2015-04-24 14:44:34 | AFTER A REVIEW OF THE PPRC RESPONSE LETTER DATED APRIL | | | 17, 2015, FROM JOSH I. LONG. AICP, TO JOHN ROACH, | | | PRINCIPAL PLANNER, THE PREVIOUSLY SUBMITTED FIRE | | | PREVENTION BUREAU COMMENTS HAVE BEEN ADDRESSED. | | | | | | THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES | | | NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
04-06-2015 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
04-06-2015 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2015-04-06 14:47:48 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. DURING CONSTRUCTION, TRASH AND DEBRIS SHALL BE | | | REMOVED OFTEN TO REDUCE THE ACCUMULATION OF POTENTIAL | | | LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. THE CONSTRUCTION OF THE BUILDING SHALL COMPLY WITH | | | THE NFPA 1, FIRE CODE, 2012 EDITION; FLORIDA FIRE | | | PREVENTION CODE, 2012 EDITION, INCLUDING MORE | | | SPECIFICALLY, CHAPTER 36, NEW MERCANTILE OCCUPANCY AND | | | THE FUEL SERVICE STRUCTURE SHALL COMPLY WITH NFPA 30A | | | AUTOMOTIVE AND MARINE SERVICE STATION CODE. | | | | | | 6. THE SEPARATION AND OPENING PROTECTION BETWEEN THE | | | OCCUPANCIES SHALL BE IN ACCORDANCE AND COMPLIANCE WITH | | | THE REQUIREMENT OF OCCUPANCY CHAPTER. | | | | | | 7. ALL KITCHEN EQUIPMENT AND OPERATIONS SHALL COMPLY | | | WITH NFPA 96, STANDARD FOR VENTILATION CONTROL AND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS. | | | EXTINGUISHMENT AND VENTILATION SYSTEM SHOP DRAWINGS | | | SHALL BE SUBMITTED SEPARATELY FOR APPROVAL. | | | | | | 8. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 9. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS | | | DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED | | | ON THE PLAN AND CLOSELY COORDINATED WITH THE BUREAU OF | | | FIRE PREVENTION. | | | | | | 10. PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED | | | FOR STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR ANY | | | MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE | | | WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED | | | WITH A MALTESE CROSS SIGN MEASURING 8 INCHES | | | HORIZONTALLY AND 8 INCHES VERTICALLY, OF A BRIGHT RED | | | REFLECTIVE COLOR. THE APPROVED SYMBOL SHALL BE PLACED | | | WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY DOOR. | | | | | | 11. NO EXIT DOOR SHALL BE LOCKED FROM THE EGRESS SIDE. | | | ANY AND ALL LOCKING MECHANISMS SHALL BE COMPLAINT WITH | | | CHAPTER 7 OF THE FLORIDA FIRE PREVENTION CODE AND | | | PRE-APPROVED (PRIOR TO INSTALLATION) BY THE BUREAU OF | | | FIRE PREVENTION. CLOSE COORDINATION WITH THE BUREAU OF | | | FIRE PREVENTION IS STRONGLY ENCOURAGED TO AVOID | | | MISUNDERSTANDINGS, MISINTERPRETATIONS AND DELAYS | | | RELATED TO EGRESS REQUIREMENTS. | | | | | | LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE OF A KEY, | | | TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM | | | THE EGRESS SIDE. | | | | | | THE RELEASING DEVICE SHOULD BE CAPABLE OF BEING | | | OPERATED WITH ONE HAND AND SHOULD NOT REQUIRE TIGHT | | | GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO | | | OPERATE. | | | | | | A THUMB TURN LOCK IS NOT PERMITTED ON THE MAIN ENTRY | | | DOOR(S). IN LIEU OF PANIC HARDWARE, THE MAIN ENTRY IS | | | PERMITTED TO BE EQUIPPED WITH A KEYED LOCK WITH | | | LOCK/UNLOCK INDICATOR WINDOW AND SIGNAGE STATING THE | | | DOOR IS TO REMAIN UNLOCKED DURING BUSINESS HOURS. NO | | | OTHER LOCKING OR LATCHING MECHANISMS ARE PERMITTED. | | | | | | 12. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 13. THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
04-27-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
04-27-2015 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
04-27-2015 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2015-10-02 13:17:10 | ALL OUTSTANDING COMMENTS ARE BEING ADDRESSED VIA A | | | CONDITIONS OF APPROVAL, THEREFORE, THE REVIEW STATUS | | | WAS SET AS "PASSED". | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
04-27-2015 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
04-27-2015 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
04-27-2015 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2015-04-28 15:44:42 | APRIL 27, 2015 | | | | | | 1. SATISFIED. PLEASE SUBMIT AN OPEN SPACE PLAN SHOWING | | | THE OPEN SPACE AREAS THAT ARE REMOVED AND ADDED WITH | | | THIS PETITION, AND CALCULATE THE NET TOTAL OPEN SPACE | | | AREA CHANGE USED IN CALCULATING LANDSCAPE REQUIREMENTS. | | | | | | 2. SATISFIED. PLEASE PROVIDE A DATA TABLE SHOWING | | | COMPLIANCE WITH SECTION 94-442 (G) FLORIDA FRIENDLY | | | LANDSCAPE REQUIREMENTS FOR THE PROPOSED LANDSCAPE | | | MATERIAL TO BE ADDED WITH THIS APPLICATION AS LISTED | | | AND REQUIRED NUMBERS OF SHADE AND FLOWERING TREES. | | | | | | 3. SATISFIED. PLEASE REVISE THE LANDSCAPE PLAN TO | | | ASSURE THE NORTH AND WEST LANDSCAPE BUFFERS MEET THE | | | REQUIREMENTS OF SECTION 94-443 (A)(2) FOR PROVIDING A | | | TREE FOR EVERY 30 FEET OF LENGTH OF THE BUFFER. | | | | | | 4. SATISFIED. PLEASE REVISE THE LANDSCAPE PLAN SHEET | | | LP-1 TO SHOW THE LOCATIONS OF THE WATER AND SEWER LINES | | | AS SHOWN ON THE ENGINEERING PLAN SHEET C-3. THE WATER | | | AND SEWER LINES PROPOSED IN THE LANDSCAPE ISLAND AT THE | | | SOUTHWEST CORNER OF THE BUILDING CONFLICT WITH THE | | | ROYAL PALM PROPOSED. | | | | | | 5. SATISFIED. PLEASE ADD LANDSCAPE ISLANDS AS NEEDED IN | | | THE PARKING ALONG CONGRESS AVE. TO HAVE 10 OR LESS | | | PARKING SPACES IN A ROW PER SECTION 94-443(C)3.A. | | | | | | 6. SATISFIED. PER SECTION 94-443(C)(3), PLEASE PROVIDE | | | AN ADDITIONAL TREE FOR THE TERMINAL LANDSCAPE ISLAND AT | | | THE WEST END OF THE ROW OF PARKING CONNECTING TO THE | | | DUMPSTER. | | | | | | 7. SATISFIED. PLEASE SUBMIT A TREE ALTERATION PERMIT | | | APPLICATION FOR THE TREES THAT ARE TO BE REMOVED OR | | | RELOCATED. RELOCATION IS RECOMMENDED FOR ANY EXISTING | | | TREES IN GOOD CONDITION, PARTICULARLY THE YELLOW | | | TABEBUIA. | | | | | | 8. SATISFIED. PLEASE PROVIDE A LIST ON SHEET LP-1 OF | | | THE SPECIES AND SIZES OF TREES AND PALMS TO BE REMOVED | | | OR RELOCATED. | | | | | | 9. SATISFIED. ANY MISSING OR DEAD PLANT MATERIAL SHOULD | | | BE REPLACED AT THIS TIME FOR THE ENTIRE PLAZA. | | | | | | ADDITIONAL COMMENTS 4/21/15: | | | | | | 10. THERE ARE CONFLICTS BETWEEN LIGHT FIXTURES SHOWN ON | | | THE LIGHTING PLAN SUBMITTED AND LANDSCAPING IN THE | | | FOLLOWING LOCATIONS: ROYAL PALMS AT NE, NW AND SW | | | CORNERS OF THE BUILDING; OAK TREES ALONG THE EAST | | | BUFFER ADJACENT TO CONGRESS AVENUE. PLEASE SHOW THE | | | LIGHT FIXTURES ON THE LANDSCAPE PLAN AND ADJUST TO | | | CORRECT ANY CONFLICTS. | | | | | | 11. THERE ARE 2 LIVE OAK TREES PROPOSED TO BE REMOVED | | | EVEN THOUGH THEY ARE IN GOOD CONDITION. THE 3 INCH | | | DIAMETER OAK NEAR THE PROPOSED DUMPSTER COULD BE EASILY | | | RELOCATED TO ANOTHER LOCATION ON THE PROPERTY. THE 8 | | | INCH DIAMETER OAK IN GOOD CONDITION ALONG 45TH STREET | | | DOES NOT CONFLICT WITH ANY PROPOSED IMPROVEMENTS AND | | | SHOULD NOT BE REMOVED. | | | | | | 12. THE GROUND MOUNTED UTILITY BOXES ALONG 45TH STREET | | | WILL BE UNSCREENED WITH THE PROPOSED REMOVAL OF THE | | | EXISTING HEDGE. PLEASE PROVIDE LANDSCAPE HEDGE | | | SCREENING AROUND THE EQUIPMENT. | | | | | | 13. PLEASE PROVIDE A ROOT BARRIER DETAIL ON SHEET L-2, | | | AND INDICATE WHERE ROOT BARRIERS WILL BE INSTALLED TO | | | PROTECT WATER AND SEWER LINES AND SIDEWALKS, ETC. | | | | | | RAY CARANCI, LANDSCAPE PLANNER | | | 561-822-1462 | | | [email protected] | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
04-01-2015 |
|
|
Cont ID |
|
| Sent By |
rcaranci |
Date |
04-01-2015 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
rcaranci |
Date |
04-01-2015 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2015-04-01 14:51:45 | | | | 1. PLEASE SUBMIT AN OPEN SPACE PLAN SHOWING THE OPEN | | | SPACE AREAS THAT ARE REMOVED AND ADDED WITH THIS | | | PETITION, AND CALCULATE THE NET TOTAL OPEN SPACE AREA | | | CHANGE USED IN CALCULATING LANDSCAPE REQUIREMENTS. | | | | | | 2. PLEASE PROVIDE A DATA TABLE SHOWING COMPLIANCE WITH | | | SECTION 94-442 (G) FLORIDA FRIENDLY LANDSCAPE | | | REQUIREMENTS FOR THE PROPOSED LANDSCAPE MATERIAL TO BE | | | ADDED WITH THIS APPLICATION AS LISTED, AND REQUIRED | | | NUMBERS OF SHADE AND FLOWERING TREES. | | | | | | 3. PLEASE REVISE THE LANDSCAPE PLAN TO ASSURE THE NORTH | | | AND WEST LANDSCAPE BUFFERS MEET THE REQUIREMENTS OF | | | SECTION 94-443 (A)(2) FOR PROVIDING A TREE FOR EVERY 30 | | | FEET OF LENGTH OF THE BUFFER. | | | | | | 4. PLEASE REVISE THE LANDSCAPE PLAN SHEET LP-1 TO SHOW | | | THE LOCATIONS OF THE WATER AND SEWER LINES AS SHOWN ON | | | THE ENGINEERING PLAN SHEET C-3. THE WATER AND SEWER | | | LINES PROPOSED IN THE LANDSCAPE ISLAND AT THE SOUTHWEST | | | CORNER OF THE BUILDING CONFLICT WITH THE ROYAL PALM | | | PROPOSED. | | | | | | 5. PLEASE ADD LANDSCAPE ISLANDS AS NEEDED IN THE | | | PARKING ALONG CONGRESS AVE. TO HAVE 10 OR LESS PARKING | | | SPACES IN A ROW PER SECTION 94-443(C)3.A. | | | | | | 6. PER SECTION 94-443(C)(3), PLEASE PROVIDE AN | | | ADDITIONAL TREE FOR THE TERMINAL LANDSCAPE ISLAND AT | | | THE WEST END OF THE ROW OF PARKING CONNECTING TO THE | | | DUMPSTER. | | | | | | 7. PLEASE SUBMIT A TREE ALTERATION PERMIT APPLICATION | | | FOR THE TREES THAT ARE TO BE REMOVED OR RELOCATED. | | | RELOCATION IS RECOMMENDED FOR ANY EXISTING TREES IN | | | GOOD CONDITION, PARTICULARLY THE YELLOW TABEBUIA. | | | | | | 8. PLEASE PROVIDE A LIST ON SHEET LP-1 OF THE SPECIES | | | AND SIZES OF TREES AND PALMS TO BE REMOVED OR | | | RELOCATED. | | | | | | 9. ANY MISSING OR DEAD PLANT MATERIAL SHOULD BE | | | REPLACED AT THIS TIME FOR THE ENTIRE PLAZA. | | | | | | RAY CARANCI LANDSCAPE PLANNER 561-822-1462 | | | |
|
|
| Review Stop |
POLICE |
POLICE |
| Rev No |
1 |
Status |
P |
Date |
04-24-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
04-24-2015 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
04-24-2015 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2015-04-28 15:37:33 | THE FOLLOWING IS FROM AN EMAIL RECEIVED FROM OFFICER | | | SETH BUXTON, DATED 04.24.2015: | | | | | | "THE 711 PROJECT APPEARS IN GOOD ORDER. I HAVE NO | | | COMMENTS AT THIS TIME." | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | WWW.WPB.ORG |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
04-27-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
04-27-2015 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
04-27-2015 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2015-10-02 13:04:04 | PURSUANT TO AN EMAIL SENT TO ALL PLAN REVIEWERS ON | | | 4/21/2015, ALL OUTSTANDING COMMENTS WERE TO BE INSERTED | | | INTO COMMUNITYPLUS BEFORE THE END OF THE DAY ON | | | 4/27/2105. IF COMMENTS WERE NOT INSERTED PRIOR TO THAT | | | TIME, IT WAS TO BE ASSUMED THAT ALL COMMENTS HAD BEEN | | | SATISFACTORILY ADDRESSED. NO COMMENTS WERE RECEIVED FOR | | | THIS REVIEW, SO THE STATUS HAS BEEN SET AS ?PASSED?. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
04-06-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
04-06-2015 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
04-06-2015 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2015-04-06 15:53:03 | PLEASE SEE COMMENTS UNDER ENGINEERING PPRC |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
P |
Date |
04-27-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
04-27-2015 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
04-27-2015 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2015-10-02 13:04:45 | PURSUANT TO AN EMAIL SENT TO ALL PLAN REVIEWERS ON | | | 4/21/2015, ALL OUTSTANDING COMMENTS WERE TO BE INSERTED | | | INTO COMMUNITYPLUS BEFORE THE END OF THE DAY ON | | | 4/27/2105. IF COMMENTS WERE NOT INSERTED PRIOR TO THAT | | | TIME, IT WAS TO BE ASSUMED THAT ALL COMMENTS HAD BEEN | | | SATISFACTORILY ADDRESSED. NO COMMENTS WERE RECEIVED FOR | | | THIS REVIEW, SO THE STATUS HAS BEEN SET AS ?PASSED?. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
04-06-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
04-06-2015 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
04-06-2015 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2015-04-06 15:54:02 | PLEASE SEE COMMENTS UNDER ENGINEERING PPRC |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
P |
Date |
05-06-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
05-06-2015 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
05-06-2015 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2015-10-02 13:07:22 | IN AN EMAIL PROVIDED BY VINCE NOEL, CITY SURVEYOR, ON | | | 5/6/2015, THE FOLLOWING COMMENT WAS MADE: | | | | | | UPON REVIEW OF THE UNDERLYING RECORD PLAT, VILLAGE | | | PROMENADE, THERE IS A 12 FOOT DEDICATED UTILITY | | | EASEMENT ALONG THE CONGRESS AVE. AND 45TH STREET | | | FRONTAGES. | | | | | | THIS COMMENT IS BEIND ADDRESSED VIA A CONDITION OF | | | APPROVAL, THEREFORE, THE REVIEW STATUS WAS SET AS | | | "PASSED". | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
04-02-2015 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
04-02-2015 |
Time |
11:18 |
Rev Time |
|
| Received By |
vnoel |
Date |
04-02-2015 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-04-02 11:28:01 | 1. CITY DATUM PER CODE IS NGVD-29. | | | 2. IF THIS IS A BOUNDARY SURVEY OF THE LEASE AREA THEN | | | CORNERS NEED SET. OR IS IT A SURVEY OF OVERALL PARCEL? | | | 3. PROPOSED IMPROVEMENTS LIE OUTSIDE OF LEASE AREA. | | | 4. SITE/CIVIL PLANS WILL REQUIRE A SEPARATE SUBMITTAL | | | TO ENGINEERING SERVICES. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
P |
Date |
04-27-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
04-27-2015 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
04-27-2015 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2015-10-02 13:13:13 | PURSUANT TO AN EMAIL SENT TO ALL PLAN REVIEWERS ON | | | 4/21/2015, ALL OUTSTANDING COMMENTS WERE TO BE INSERTED | | | INTO COMMUNITYPLUS BEFORE THE END OF THE DAY ON | | | 4/27/2105. IF COMMENTS WERE NOT INSERTED PRIOR TO THAT | | | TIME, IT WAS TO BE ASSUMED THAT ALL COMMENTS HAD BEEN | | | SATISFACTORILY ADDRESSED. NO COMMENTS WERE RECEIVED FOR | | | THIS REVIEW, SO THE STATUS HAS BEEN SET AS ?PASSED?. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
F |
Date |
04-06-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
04-06-2015 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
04-06-2015 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2015-04-06 15:53:39 | PLEASE SEE COMMENTS UNDER ENGINEERING PPRC |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
05-06-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
05-06-2015 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
05-06-2015 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2015-10-02 13:19:38 | ALL OUTSTANDING COMMENTS FROM THE ORIGINAL REVIEW HAVE | | | BEEN ADDRESSED OR ARE BEING ADDRESSED VIA CONDITIONS OF | | | APPROVAL. ADDITIONALLY, THE FOLLOWING ITEMS WILL BE | | | ADDRESSED AS CONDITIONS: | | | | | | 1) THERE ARE RESTRICTIONS AND COVENANTS OUTLINED IN THE | | | WARRANTY DEED RECORDED IN ORB 4469 PG 0541, WHICH | | | INCLUDE, BUT IS NOT LIMITED TO THE FOLLOWING... | | | | | | "NO BUILDING OF ANY DESCRIPTION AND NO SIGN OF ANY | | | DESCRIPTION SHALL BE ERECTED UPON OR ALLOWED TO OCCUPY | | | ANY OF THE SAID PREMISES UNTIL ALL THE EXTERIOR PLANS | | | AND SPECIFICATIONS OF SUCH BUILDING OR ADDITION | | | (INCLUDING BUT NOT LIMITED TO, ALL EXTERIOR | | | ARCHITECTURAL DRAWNINGS AND LANDSCAPE PLANS) AND THE | | | LOCATION THEREON, SHALL HAVE THE APPROVAL IN WRITING OF | | | PERINI LAND AND DEVELOPMENT COMPANY, OR ITS SUCCESSORS | | | OR ASSIGNS." | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
04-08-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
04-08-2015 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
04-08-2015 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2015-04-08 12:45:35 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 04.08.2015 | | | PROJECT NO.: Z15030022 | | | CASE NO.: PB 785H | | | ADDRESS: 2100 45TH STREET | | | APPLICANT/CONTACT: BRIAN SEYMOUR, ESQ. AND JOSHUA I. | | | LONG, AICP | | | TELEPHONE NO.: 561.650.0621 | | | SCOPE OF REVIEW: NEW CONVENIENCE STORE WITH FUEL SALES | | | AND RETAIL SPACE. | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. IT APPEARS THAT THERE ARE LIENS AGAINST THE | | | PROPERTY, AS WELL AS OTHER PROPERTY OWNERS. PURSUANT TO | | | SECTION 94-10 OF THE CITY?S ZONING AND LAND DEVELOPMENT | | | REGULATIONS, NO APPLICATIONS WILL BE PROCESSED BY THE | | | CITY UNTIL FINANCIAL DEBTS TO THE CITY ARE RESOLVED. | | | | | | 2. NOTE THAT ALL NEW PRIVATE DEVELOPMENT, NEW | | | CONSTRUCTION, RENOVATION OR REMODELING, WHERE TOTAL | | | VERTICAL CONSTRUCTION COSTS OF ALL BUILDINGS ON A | | | PROJECT SITE ARE EQUAL TO OR GREATER THAN $500,000.00, | | | IS SUBJECT TO THE ART IN PUBLIC PLACES REQUIREMENTS | | | OUTLINED IN CHAPTER 78, ARTICLE V OF THE CITY?S CODE OF | | | ORDINANCES. | | | | | | 3. PLEASE ADDRESS THE COMMENTS FROM THE PALM BEACH | | | COUNTY DEPARTMENT OF ENGINEERING ? TRAFFIC DIVISION, | | | IDENTIFIED IN THEIR LETTER DATED 4/2/2015. | | | | | | 4. PURSUANT TO THE DEVELOPMENT APPLICATION, THE SURVEY | | | SHALL BE AN ALTA/ACSM LAND TITLE SURVEY, SHALL INCLUDE | | | ALL ITEMS LISTED IN SECTION K OF THE DEVELOPMENT | | | APPLICATION, AND SHALL BE ACCOMPANIED BY A CURRENT | | | OWNERSHIP AND ENCUMBRANCE (O&E) REPORT, OR A CURRENT | | | TITLE POLICY. | | | | | | 5. AN OVERALL SITE PLAN SHALL BE PROVIDED FOR THE | | | ENTIRE CPD, AND THE SITE DATA TABLE AND ALL | | | CALCULATIONS SHALL BE ADJUSTED TO SHOW COMPLIANCE | | | ACROSS THE ENTIRE SITE, NOT JUST THE LEASE AREA. | | | | | | 6. PLEASE REVIEW ALL CALCULATIONS IN THE SITE DATA | | | TABLE, INCLUDING BUILDING AREA, PARKING, ETC. THEY | | | APPEAR TO BE INCORRECT. | | | | | | 7. OUTSTANDING UTILITY LETTERS SHALL BE PROVIDED. | | | | | | 8. THE AREA ALONG 45TH STREET SHOULD BE MODIFIED. IT | | | WAS DISCUSSED IN PREVIOUS MEETINGS THAT THE EXISTING | | | PARKING WAS GOING TO BE REMOVED SO THAT ADDITIONAL | | | LANDSCAPING COULD BE INSTALLED, INCLUDING UNDULATIONS | | | IN THE GRADE TO ENHANCE THE BUFFER AND SCREEN PUMP AREA | | | FROM THE 45TH STREET RIGHT-OF-WAY. PLEASE NOTE, IT IS | | | STILL THE PREFERENCE OF STAFF THAT THE LOCATIONS OF THE | | | BUILDING AND PUMP ISLANDS BE REVERSED. | | | | | | 9. STAFF STILL HAS CONCERN WITH REGARD TO THAT AREA | | | DESIGNATED FOR THE FUEL TANKS AND THE LARGE AMOUNT OF | | | OPEN IMPERVIOUS SURFACE AREA. | | | | | | 10. THERE NEEDS TO BE AN ACCESSIBLE ROUTE FROM THE | | | PUBLIC RIGHT-OF-WAY TO RETAIL AND CONVENIENCE STORE. | | | | | | 11. THE WIDTH OF THE DRIVE AISLE BETWEEN THE BUILDING | | | AND PUMP ISLANDS SHOULD BE REDUCED FROM 30 FEET DOWN TO | | | 24 FEET. | | | | | | 12. THE DRIVE AISLE BETWEEN THE LOADING SPACE AND THE | | | DUMPSTER SHOULD BE REDUCED FROM 27.4 FEET TO 24 FEET | | | AND LANDSCAPING SHOULD BE INSTALLED ALONG THE BACKSIDE | | | OF THE BUILDING. | | | | | | 13. FOUNDATION PLANTING SHOULD BE INSTALLED ACROSS THE | | | FRONT (NORTH SIDE) OF THE BUILDING. | | | | | | 14. THE ELEVATIONS INDICATE THE INSTALLATION OF A | | | ?REDBOX? VENDING MACHINE AS WELL AS AN ICE MACHINE. | | | THESE ITEMS SHOULD BE LOCATED WITHIN THE BUILDING. | | | ADDITIONALLY, THEY IMPEDE WITH THE SIDEWALK PROPOSED IN | | | FRONT OF THE BUILDING. | | | | | | 15. THE ELEVATIONS ALSO INDICATE A PROPANE STORAGE UNIT | | | IN FRONT OF THE BUILDING. THIS SHOULD BE RELOCATED AND | | | SCREENED, AND SHOULD NOT ENCROACH INTO THE REQUIRE | | | SIDEWALK. | | | | | | 16. BICYCLE PARKING SHALL BE PROVIDED AND A DETAIL | | | SHALL BE INCLUDED ON THE PLANS. | | | | | | 17. A DETAIL SHALL BE PROVIDED FOR THE DUMPSTER | | | ENCLOSURE. | | | | | | 18. A PARKING DETAIL SHALL BE PROVIDED. | | | | | | 19. ADDITIONAL ENHANCEMENTS NEED TO BE MADE TO THE | | | ELEVATIONS. STAFF HAS CONCERN WITH REGARD TO THE FACT | | | THAT THERE IS LITTLE ARCHITECTURAL DETAIL, NO RELIEF, | | | ETC. | | | | | | 20. THE PROPOSED DEVELOPMENT SHALL BE REVIEWED AND | | | APPROVED BY THE CITY?S POLICE DEPARTMENT. PLEASE | | | COORDINATE WITH OFFICER SETH BUXTON (561-822-1620 OR | | | [email protected]). | | | | | | 21. LOCATION OF THE PROPOSED FREE-STANDING SIGN | | | CONFLICTS WITH EXISTING PALM TREES. | | | | | | 22. ALL SITE LIGHTING SHALL BE FULL CUT-OFF. | | | | | | 23. ALL CANOPY LIGHTS SHALL BE RECESSED. | | | | | | 24. THE ELEVATIONS INDICATE WALL-MOUNTED LIGHTING THAT | | | IS NOT REFLECTED IN THE PHOTOMETRIC PLANS. | | | | | | 25. THE SITE PLAN SHALL NOTE THE LOCATION OF ALL | | | FREESTANDING SIGNS, SETBACKS FROM ADJACENT PROPERTY | | | LINES AND/OR RIGHTS-OF-WAY, ETC. | | | | | | 26. AN ACCESSIBLE PARKING SPACE WILL BE REQUIRED FOR | | | THE RETAIL SPACE; PLEASE CONFIRM WITH THE CITY?S | | | BUILDING DIVISION. | | | ___________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | | | | F) IN ORDER TO BE CONSIDERED FOR THE MAY 19, 2015, | | | PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE | | | SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED | | | DOCUMENTS/PLANS NO LATER THAN FRIDAY, APRIL 17, 2015. | | | | | | G) TO BE PLACED ON THE MAY 19, 2015, PLANNING BOARD | | | AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO LATER | | | THAN MAY 4, 2015. SIGNAGE SHALL CONFORM AND BE | | | INSTALLED WITH THE REQUIREMENTS OF THE CITY?S ZONING | | | AND LAND DEVELOPMENT REGULATIONS, AS ALSO PROVIDED IN | | | THE DEVELOPMENT APPLICATION. A SIGNED AND NOTARIZED | | | AFFIDAVIT SHALL BE PROVIDED BY THE DEADLINE REFERENCED | | | ABOVE. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
| |