Plan Review Details - Project Z15020010
| Plan Review Stops For Project Z15020010 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
08-18-2015 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
08-18-2015 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
08-18-2015 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2015-08-18 15:41:29 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. THE WHEELCHAIR USER MUST BE ABLE TO OPEN/CLOSE THE | | | DOOR WHILE ON THE LEVEL LANDING, AND NOT PARTIALLY ON | | | THE SLOPED PART OF THE RAMP. THEREFORE, FOR THE RAMP | | | LEADING TO TIJUANA FLATS RESTAURANT, WHEN SUBMITTED FOR | | | PERMIT, THE PLANS SHALL SHOW THAT THE FRONT EDGE OF THE | | | TOP LANDING WILL BE MIN. 36 INCHES FROM THE LEADING | | | EDGE OF THE DOOR SWING, AND THE RAMP MUST BE MIN. 60 | | | INCHES WIDE, PER FIGURE 404.2.4.1(D) OF FLORIDA | | | ACCESSIBILITY CODE. | | | | | | 3. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL | | | SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS | | | WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND | | | OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA | | | BUILDING CODE | | | | | | 4. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH | | | ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND | | | OPENING PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 OF | | | THE FLORIDA BUILDING CODE SHALL BE VERIFIED. | | | | | | 5. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SWIMMING POOLS AND SPAS, GAS SYSTEMS, GENERATORS, | | | FIRE ALARM SYSTEMS, FIRE SPRINKLER AND OTHER FIRE | | | SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, SITE | | | LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 6. FOR STREET ADDRESSING, CONTACT MICHAEL ORIO, GIS | | | SUPPORT SPECIALIST, AT (561) 494 1080, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
03-11-2015 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
03-11-2015 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
03-11-2015 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2015-03-11 10:51:46 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE | | | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH | | | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE | | | ADDRESSED FOR PERMITTING. | | | | | | 2. . DISPERSION OF ACCESSIBLE PARKING SPACES. SHEET | | | C-03 CURRENTLY SHOWS REGULAR PARKING SPACES CLOSER TO | | | THE ENTRANCE OF THE RESTAURANT ON THE EAST SIDE (DUNKIN | | | DONUTS) THAN THE ACCESSIBLE PARKING SPACES. PER SECTION | | | 208.3 OF FLORIDA ACCESSIBILITY CODE ACCESSIBLE PARKING | | | SPACES ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE | | | OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE | | | ENTRANCE FOR EACH BUILDING. THE DESIGN OF ACCESSIBLE | | | PARKING SPACES SHALL COMPLY WITH SECTION 502 OF FLORIDA | | | ACCESSIBILITY CODE | | | | | | 3. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL | | | SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS | | | WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND | | | OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA | | | BUILDING CODE | | | | | | 4. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH | | | ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND | | | OPENING PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 OF | | | THE FLORIDA BUILDING CODE SHALL BE VERIFIED. | | | | | | 5. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS | | | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE | | | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED | | | FOR SWIMMING POOLS AND SPAS, GAS SYSTEMS, GENERATORS, | | | FIRE ALARM SYSTEMS, FIRE SPRINKLER AND OTHER FIRE | | | SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, SITE | | | LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. | | | | | | 6. FOR STREET ADDRESSING, CONTACT MICHAEL ORIO, GIS | | | SUPPORT SPECIALIST, AT (561) 494 1080, OR BY EMAIL: | | | [email protected] | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
2 |
Status |
P |
Date |
08-31-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
08-31-2015 |
Time |
|
Rev Time |
0.00 |
| Received By |
jroach |
Date |
08-31-2015 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-09-01 14:00:49 | PLANNING STAFF RECEIVED NO RESPONSE FOLLOWING REQUESTS | | | ON 8/5/2015 AND 8/14/2015 TO REVIEW THE RESUBMITTED | | | PLANS. AS INDICATED IN THE EMAILS, IF NO RESPONSE WAS | | | RECEIVED IT WAS TO BE ASSUMED THAT ALL COMMENTS HAD | | | BEEN ADDRESSED. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
ENG - PPRC |
ENGINEERING - PPRC |
| Rev No |
1 |
Status |
F |
Date |
03-10-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-10-2015 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-10-2015 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2015-03-10 11:40:18 | PUBLIC WORKS DEPT. | | | | | | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL | | | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION | | | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE | | | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT | | | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT | | | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | | | | 1. PLEASE PROVIDE A COPY OF THE PHOTOMETRIC PLAN | | | DEMONSTRATING THE PROPOSED DESIGN MEETS THE | | | REQUIREMENTS OF CITY ORDINANCE 94-309 AND 94-113. | | | | | | 2. PLEASE PROVIDE A PLAN SHOWING THE ENTIRE DEVELOPMENT | | | WITH AN AUTOTURN ANALYSIS DEMONSTRATING THE SOLID WASTE | | | COLLECTION VEHICLE CAN ACCESS THE PROPOSED DUMPSTER | | | LOCATION FROM THE MAIN ROADWAY. THE TRASH | | | DUMPSTER/COMPACTORS MUST LOCATED IN AREAS EASILY | | | SERVICED BY THE CITY SANITATION EQUIPMENT AND MANPOWER | | | PER SECTION 74-35(A)(5) OF THE CODE OF ORDINANCES. | | | | | | 3. SUBMIT DEMAND, FLOW, AND YARDAGE CALCULATIONS FOR | | | THE POTABLE WATER, SANITARY SEWER, AND SOLID WASTE | | | COLLECTION. | | | | | | 4. THE PROPOSED WESTERN GREASE TRAP APPEARS TO BE | | | OUTSIDE OF THE AREA DESCRIBED IN THE SUBMITTED WARRANTY | | | DEED. PLEASE PROVIDE DOCUMENTATION AUTHORIZING THE | | | CONSTRUCTION OUTSIDE OF THE OUTPARCEL BOUNDARY. | | | | | | 5. PLEASE SUBMIT AN APPLICATION FOR A DEVELOPMENT | | | PERMIT TO THE ENGINEERING DEPARTMENT. APPLICATION FORMS | | | CAN BE FOUND AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | (SECTIONS 2-421 AND 78-432, CODE OF ORDINANCES) | | | | | | KELLY CRANFORD, PE | | | CITY LAND DEVELOPMENT ENGINEER | | | [email protected] | | | 561-494-1098 (OFFICE) | | | | | | VINCE NOEL, PSM | | | CITY SURVEYOR / REAL ESTATE SUPERVISOR | | | [email protected] | | | 561-494-1096 | | | | | | BRIAN COLLINS, PE | | | CITY TRAFFIC ENGINEER | | | [email protected] | | | 561-494-1040 | | | | | | FERDINAND RIVERA | | | PUBLIC WORKS OPERATIONS MANAGER | | | [email protected] | | | 561-822-2076 | | | | | | TRACY WARD, PE | | | CITY STORMWATER ENGINEER | | | 561-494-1120 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
08-17-2015 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
08-17-2015 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
08-17-2015 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2015-08-17 10:17:37 | AFTER A REVIEW OF THE PPRC RESPONSE LETTER DATED JULY | | | 28, 2015, FROM THOMAS ENGINEERING GROUP, TO JOHN P. | | | ROACCH, AICP, THE PREVIOUSLY SUBMITTED FIRE PREVENTION | | | BUREAU COMMENTS HAVE BEEN ADDRESSED. | | | | | | THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES | | | NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT | | | THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE | | | REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
03-09-2015 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
03-09-2015 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
03-09-2015 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2015-03-09 15:38:44 | THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM | | | BEACH FIRE RESCUE. | | | | | | THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE | | | DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE. | | | ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS | | | ARE SUBMITTED FOR PERMIT. | | | THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE | | | PROPOSED PROJECT. | | | | | | 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. | | | | | | 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY | | | IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING | | | ALL CONSTRUCTION ACTIVITIES. | | | | | | 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM | | | ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. | | | ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND | | | AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT | | | WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS. | | | | | | 4. TRASH AND DEBRIS IS TO BE REMOVED FROM THE SITE | | | DAILY OR MORE OFTEN TO REDUCE THE ACCUMULATION OF | | | POTENTIAL LIFE AND FIRE SAFETY HAZARDS. | | | | | | 5. ALL BUILDINGS SHALL COMPLY WITH THE FLORIDA FIRE | | | PREVENTION CODE, 2012 EDITION AND NFPA 1, FIRE CODE, | | | 2012 EDITION, AND ALL OTHER APPLICABLE CODES. | | | | | | 6. THE SEPARATION AND OPENING PROTECTION BETWEEN THE | | | SEPARATE OCCUPANCIES SHALL BE IN ACCORDANCE AND | | | COMPLIANCE WITH THE SPECIFIC AND MOST STRINGENT | | | PROVISION REQUIREMENT. | | | | | | 7. ALL VERTICAL AND HORIZONTAL FIRE SEPARATIONS FOR | | | THIS BUILDING SHALL BE CLEARLY IDENTIFIED AND INDICATED | | | ON THE PLANS. | | | | | | 8. . ALL EXIT DISCHARGE LOCATIONS SHALL BE CLEARLY | | | ILLUSTRATED ON THE PLAN. | | | | | | 9. ALL ILLUMINATED EXIT SIGNS AND EMERGENCY LIGHTING | | | EQUIPMENT SHALL BE ILLUSTRATED ON THE PLAN. | | | | | | 10. ALL KITCHEN EQUIPMENT AND OPERATIONS SHALL COMPLY | | | WITH NFPA 96, STANDARD FOR VENTILATION CONTROL AND FIRE | | | PROTECTION OF COMMERCIAL COOKING OPERATIONS. | | | EXTINGUISHMENT AND VENTILATION SYSTEM SHOP DRAWINGS | | | SHALL BE SUBMITTED SEPARATELY FOR APPROVAL. | | | | | | 11. ALL PORTABLE FIRE EXTINGUISHERS LOCATIONS SHALL BE | | | CLEARLY IDENTIFIED AND INDICATED ON THE PLAN. | | | | | | 12. COMPLETE LIFE SAFETY PLANS FOR EACH OCCUPANCY SHALL | | | BE PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL | | | DISTANCES, COMMON PATHS OF TRAVEL, DEAD-END CORRIDORS, | | | EXIT SIGNS, EMERGENCY LIGHTING, EXITS LEADING TO A | | | PUBLIC WAY, FIRE EXTINGUISHER LOCATIONS, AND ALL FIRE | | | SAFETY FEATURES AND EQUIPMENT. | | | | | | 13. OCCUPANT LOADS FOR ALL SPACES SHALL BE DETERMINED | | | AND SUBMITTED WITH THE SUBMITTED PLAN AND WHEN APPROVED | | | THEY ARE REQUIRED TO BE POSTED WHERE APPLICABLE. | | | | | | 14. PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED | | | FOR STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR ANY | | | MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE | | | WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED | | | WITH A MALTESE CROSS SIGN MEASURING 8 INCHES | | | HORIZONTALLY AND 8 INCHES VERTICALLY, OF A BRIGHT RED | | | REFLECTIVE COLOR. THE APPROVED SYMBOL SHALL BE PLACED | | | WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY DOOR. | | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER "R". | | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER "F". | | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | | | | | | | | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
08-18-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
08-18-2015 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
08-18-2015 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2015-08-18 14:16:15 | PURSUANT TO AN EMAIL FROM RAY CARANCI, LANDSCAPE | | | PLANNER, DATED AUGUST 17, 2015, THE PLAN APPEARS TO BE | | | ACCEPTABLE, SPECIAL ATTENTION SHOULD BE MADE TO | | | CONSTRUCTION OF THE BUILDING AND INFRASTRUCTURE TO | | | ENSURE THAT IT IS BUILT WITHOUT DAMAGING THE EXISTING | | | PARKING LOT TREES AND SHRUBS AND THE ROYAL PALMS ALONG | | | THE BACK OF THE PROPOSED BUILDING. PER CODE, TREE | | | PROTECTION BARRIERS MUST BE INSTALLED. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
2 |
Status |
P |
Date |
08-31-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
08-31-2015 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
08-31-2015 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2015-09-01 14:01:59 | PLANNING STAFF RECEIVED NO RESPONSE FOLLOWING REQUESTS | | | ON 8/5/2015 AND 8/14/2015 TO REVIEW THE RESUBMITTED | | | PLANS. AS INDICATED IN THE EMAILS, IF NO RESPONSE WAS | | | RECEIVED IT WAS TO BE ASSUMED THAT ALL COMMENTS HAD | | | BEEN ADDRESSED. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
PW |
PUBLIC WORKS |
| Rev No |
1 |
Status |
F |
Date |
03-10-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-10-2015 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-10-2015 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2015-03-10 11:41:15 | PLEASE SEE ENGINEERING PPRC COMMENTS. |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
2 |
Status |
P |
Date |
08-31-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
08-31-2015 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
08-31-2015 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2015-09-01 14:02:32 | PLANNING STAFF RECEIVED NO RESPONSE FOLLOWING REQUESTS | | | ON 8/5/2015 AND 8/14/2015 TO REVIEW THE RESUBMITTED | | | PLANS. AS INDICATED IN THE EMAILS, IF NO RESPONSE WAS | | | RECEIVED IT WAS TO BE ASSUMED THAT ALL COMMENTS HAD | | | BEEN ADDRESSED. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
P |
Date |
03-10-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-10-2015 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-10-2015 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2015-03-10 11:41:45 | PLEASE SEE ENGINEERING PPRC COMMENTS. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
2 |
Status |
F |
Date |
08-05-2015 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
08-05-2015 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
08-05-2015 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-08-05 15:03:33 | REVISE SURVEY TO REFLECT RECORDED PLAT INFORMATION. |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
03-10-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-10-2015 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-10-2015 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2015-03-10 11:42:32 | PLEASE SEE ENGINEERING PPRC COMMENTS. |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
2 |
Status |
P |
Date |
08-31-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
08-31-2015 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
08-31-2015 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2015-09-01 14:03:17 | PLANNING STAFF RECEIVED NO RESPONSE FOLLOWING REQUESTS | | | ON 8/5/2015 AND 8/14/2015 TO REVIEW THE RESUBMITTED | | | PLANS. AS INDICATED IN THE EMAILS, IF NO RESPONSE WAS | | | RECEIVED IT WAS TO BE ASSUMED THAT ALL COMMENTS HAD | | | BEEN ADDRESSED. | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
TRAFFIC |
TRAFFIC ENGINEERING |
| Rev No |
1 |
Status |
P |
Date |
03-10-2015 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
03-10-2015 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
03-10-2015 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2015-03-10 11:42:11 | PLEASE SEE ENGINEERING PPRC COMMENTS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
08-31-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
08-31-2015 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
08-31-2015 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2015-09-01 14:06:21 | PLEASE NOTE THAT THIS APPROVAL IS GRANTED SUBJECT TO | | | THE FOLLOWING CONDITIONS: | | | | | | 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR THE | | | ABOVE-REFERENCED IMPROVEMENTS: | | | | | | A. A DETAIL OF THE PROPOSED BIKE RACK SHALL BE | | | PROVIDED; | | | | | | B. A PARKING SPACE STRIPING DETAIL SHALL BE PROVIDED; | | | | | | | | | C. THE SITE PLAN SHALL BE REVISED TO INDICATE THAT THE | | | BIKE RACKS ARE SEPARATED BY 30 INCHES (24 INCHES ON THE | | | ENDS - AS SHOWN - IS OK); AND | | | | | | D. THE NUMBER OF WALL-MOUNTED SIGNS SHALL BE LIMITED | | | TO ONE (1) PER BUSINESS, PLUS TWO (2) ADDITIONAL SIGNS; | | | PROVIDING FOR A MAXIMUM OF FOUR (4) SIGNS ON THE | | | BUILDING. | | | | | | 2. SPECIAL ATTENTION SHALL BE MADE TO THE CONSTRUCTION | | | OF THE BUILDING AND ASSOCIATED INFRASTRUCTURE TO ENSURE | | | THAT EXISTING PARKING LOT TREES AND SHRUBS, AND THE | | | ROYAL PALMS ALONG THE SOUTHEAST SIDE OF THE PROPOSED | | | BUILDING, ARE NOT DAMAGED. PER THE CITY?S CODE OF | | | ORDINANCES, TREE PROTECTION BARRIERS MUST BE INSTALLED. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
08-14-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
08-14-2015 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
08-14-2015 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2015-08-14 11:48:43 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 08.14.2015 | | | PROJECT NO.: Z15020010 | | | CASE NO.: PB 1603F | | | ADDRESS: 2101 PALM BEACH LAKES BOULEVARD | | | APPLICANT/CONTACT: BARRY ROSS | | | TELEPHONE NO.: 954.452.5000 | | | SCOPE OF REVIEW: NEW FREESTANDING RESTAURANT BUILDING. | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. DETAIL OF THE PROPOSED BIKE RACK SHALL BE PROVIDED. | | | | | | 2. PARKING SPACE STRIPING DETAIL SHALL BE PROVIDED. | | | | | | 3. BIKE RACKS SHOULD BE SEPARATED BY 30 INCHES (24 | | | INCHES ON THE ENDS ? AS SHOWN ? IS OK). | | | | | | 4. THE NUMBER OF WALL-MOUNTED SIGNS IS LIMITED TO ONE | | | (1) PER BUSINESS, PLUS TWO (2) ADDITIONAL SIGNS. THIS | | | PROVIDES FOR A MAXIMUM OF FOUR (4) SIGNS ON THE | | | BUILDING. | | | | | | ___________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 6 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
03-11-2015 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
03-11-2015 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
03-11-2015 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2015-03-11 10:38:18 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 03.11.2015 | | | PROJECT NO.: Z15020010 | | | CASE NO.: PB 1603F | | | ADDRESS: 2101 PALM BEACH LAKES BOULEVARD | | | APPLICANT/CONTACT: BARRY ROSS | | | TELEPHONE NO.: 954.452.5000 | | | SCOPE OF REVIEW: NEW FREESTANDING RESTAURANT BUILDING. | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS: | | | | | | 1. BICYCLE PARKING SHALL BE PROVIDED. PLEASE CONTACT ME | | | FOR BIKE RACK REQUIREMENTS. | | | | | | 2. PLEASE CLARIFY THE BASIS FOR THE WALKWAY DESIGN ON | | | THE NORTHWEST SIDE OF THE BUILDING? THE PROPOSED DESIGN | | | SIGNIFICANTLY MINIMIZES THE AMOUNT AND SIZE OF THE | | | PLANTING AREA AROUND THE FOUNDATION OF THE BUILDING. | | | | | | 3. THE SITE DATA TABLE SHOULD REFERENCE THAT THE | | | PARKING IS CALCULATED/PROVIDED IN ACCORDANCE WITH | | | RESOLUTION NO. 1-15, APPROVED ON JANUARY 20, 2015. | | | | | | 4. THE SITE DATA TABLE SHOULD INDICATE THAT LANDSCAPE | | | BUFFERS ARE NOT REQUIRED INTERIOR TO THE COMMERCIAL | | | PLANNED DEVELOPMENT (CPD), AS PROVIDED IN RESOLUTION | | | NO. 1-15, APPROVED ON JANUARY 20, 2015. | | | | | | 5. CAN ADDITIONAL CURBING AND LANDSCAPE AREA BE ADDED | | | SOUTH OF THE LOADING SPACE, ADJACENT TO THE OIL WASTE | | | STORAGE AREA? | | | | | | 6. SIGNAGE WILL BE REVIEWED AT TIME OF APPLICATION FOR | | | A BUILDING PERMIT. PLEASE NOTE THAT ALL OF THE DUNKIN | | | DONUTS? GRAPHICS COUNT AS SIGNAGE AND MAY NOT BE | | | PERMITTED. | | | | | | 7. STAFF WOULD LIKE TO WORK WITH THE | | | APPLICANT/ARCHITECT ON A THE BUILDING ELEVATIONS TO | | | ENSURE COMPATIBILITY WITH THE EXISTING DEVELOPMENT, | | | BETTER ADDRESS THE FACADES, ETC. | | | | | | 8. THE SIZE OF THE DUMPSTER ENCLOSURES DOES NOT APPEAR | | | TO MATCH THE MINIMUM SPECIFICATIONS, AS OUTLINED IN THE | | | DETAIL ON SHEET C-04. DEVIATIONS FROM THE MINIMUM | | | SPECIFICATIONS SHALL REQUIRE THE APPROVAL OF THE CITY?S | | | SANITATION DIVISION. | | | ___________________________________________ | | | | | | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: | | | | | | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL | | | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. | | | | | | B) 6 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE | | | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X | | | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. | | | | | | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO | | | ADDITIONAL COMMENTS. | | | | | | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE | | | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE | | | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL | | | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. | | | | | | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) | | | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED | | | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE | | | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE | | | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN ROACH, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | PHONE: 561.822.1448 | | | FAX: 561.822.1460 | | | | | | EMAIL: [email protected] | | | | | | WWW.WPB.ORG | | | |
|
|
| |