Plan Review Details - Project Z14120035
Plan Review Stops For Project Z14120035
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 01-13-2015 Cont ID  
Sent By rbrown Date 01-13-2015 Time 22:16 Rev Time 0.00
Received By rbrown Date 01-13-2015 Time 22:16 Sent To  
Notes
2015-01-13 22:18:32DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR PERMITTING.
  
 2. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL
 SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS
 WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND
 OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA
 BUILDING CODE
  
 3. ALL APPLICABLE PERMITS AND SUB-PERMITS MUST BE
 OBTAINED BEFORE COMMENCING THE WORK. SEPARATE PERMITS,
 PLANS AND FEES, ARE REQUIRED FOR SWIMMING POOLS AND
 SPAS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, FIRE
 SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, GREASE
 INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, SITE
 IRRIGATION, ETC.
  
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 2 Status P Date 02-11-2015 Cont ID  
Sent By cranford Date 02-11-2015 Time 10:45 Rev Time 0.00
Received By cranford Date 02-11-2015 Time 10:45 Sent To  
Notes
***NONE***

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 01-14-2015 Cont ID  
Sent By cranford Date 01-14-2015 Time 07:56 Rev Time 0.00
Received By cranford Date 01-14-2015 Time 07:56 Sent To  
Notes
2015-01-14 07:55:49PUBLIC WORKS DEPT.
  
 THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT
 APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT
 HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/
  
 1. PLEASE PROVIDE AN AUTOTURN ANALYSIS FOR THE
 SANITATION TRUCK ACCESSING THE PROPOSED DUMPSTER
 LOCATION BACKING OUT OF THE PROPOSED HANDICAPPED
 PARKING SPACE.
  
 2. PLEASE PROVIDE A COPY OF THE BOUNDARY SURVEY FOR
 THIS PARCEL.
  
 3. HOW WILL THE SANITATION TRUCKS GAIN ACCESS TO THE
 DUMPSTER ENCLOSURE? WILL THE GATES REMAIN OPEN DURING
 CERTAIN HOURS?
  
 4. PLEASE REVISE THE DRIVEWAY APRONS TO MEET THE CITY?S
 ENGINEERING DESIGN STANDARDS (GC-7). HTTP://WPB.ORG/ENG
 INEERING/ENGINEERING-SERVICES/ENGINEERING-STANDARDS/
  
 5. PLEASE SHOW THE DETECTABLE WARNING STRIPS A THE
 PROPOSED SIDEWALK RAMPS.
  
 6. CONSIDER CAPPING THE GAS LINE NEAR THE PROPERTY LINE
 RATHER THAN LEAVING IT IN PLACE UNDER THE PROPOSED
 CONSTRUCTION.
  
 7. IF A NEW TAP IS NEEDED FOR THE PROPOSED FIRE LINE,
 IT SHOULD BE MADE TO THE 8-INCH WATER MAIN ON PARK
 PLACE.
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
 [email protected]
 561-494-1098 (OFFICE)
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status   Date 01-08-2015 Cont ID  
Sent By pleduc Date 01-08-2015 Time 11:36 Rev Time 0.00
Received By pleduc Date 01-08-2015 Time 11:11 Sent To  
Notes
2015-01-08 11:36:27THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. TRASH AND DEBRIS IS TO BE REMOVED FROM THE SITE
 DAILY OR MORE OFTEN TO REDUCE THE ACCUMULATION OF
 POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. THIS IS MULTIPLE OCCUPANCY BUILDING INCLUDING
 STORAGE, DORMITORY, BUSINESS AND SHALL COMPLY WITH THE
 APPLICABLE CODE.
  
 6. SEPARATE SHOP DRAWINGS ARE REQUIRED FOR THE FIRE
 SPRINKLER SYSTEM AND MONITORED FIRE ALAM.
  
 7. ALL KITCHEN EQUIPMENT AND OPERATIONS SHALL COMPLY
 WITH NFPA 96, STANDARD FOR VENTILATION CONTROL AND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS.
 EXTINGUISHMENT AND VENTILATION SYSTEM SHOP DRAWINGS
 SHALL BE SUBMITTED SEPARATELY FOR APPROVAL.
  
 8. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS
 BUILDING.
  
 9. TACTILE SIGNAGE SHALL BE INSTALLED AT ALL EXIT
 DOORS.
  
 10. THE FIRE RATING OF THE STAIRWELL INDICATED A 2-HR
 RATING. ANY OPENING IN THE RATED WALL SHALL MAINTAIN
 THE 2-HR RATING. THERE ARE WINDOWS IN THE RATED
 STAIRWELLS THAT DO NOT SHOW REQUIRED FIRE RATING.
  
 11. REQUIRED CORRIDOR FIRE RATINGS SHALL BE CLEARLY
 INDICATED WHERE APPLICABLE, INCLUDING ON THE 2ND FLOOR.
  
 12. PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED
 FOR STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE
 CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR ANY
 MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE
 WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED
 WITH A MALTESE CROSS SIGN MEASURING 8 INCHES
 HORIZONTALLY AND 8 INCHES VERTICALLY, OF A BRIGHT RED
 REFLECTIVE COLOR. THE APPROVED SYMBOL SHALL BE PLACED
 WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY DOOR.
  
 13. THERE IS NO RATING INDICATED OF THE GENERATED ROOM
 WALLS. THE DOOR IS INDCATED AS BEING A 2 HOUR DOOR;
 HOWEVER, THE WALLS REQUIRE THE SAME RATING.
  
  
  
  
  

Review Stop L LANDSCAPING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 1 Status F Date 01-14-2015 Cont ID  
Sent By cranford Date 01-14-2015 Time 07:56 Rev Time 0.00
Received By cranford Date 01-14-2015 Time 07:56 Sent To  
Notes
2015-01-14 07:57:01SEE ENG PPRC COMMENTS

Review Stop STORM STORMWATER
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2015-02-03 17:29:151. REVISE BUILDING FFE'S ON SHEETS C1.01, C2.01 AND
 C2.02 TO BE IN REFERENCE TO NGVD.
  
 2. ON THE POLLUTION PREVENTION PLAN AND DETAILS SHEETS,
 SHOW FLOATING TURBIDITY BARRIERS IN CANAL AND PROVIDE A
 DETAIL.
  
 3. SITE PLAN COMMENTS:
 A. CONSIDER WIDENING THE SIDEWALK BETWEEN THE PARALLEL
 PARKING SPACES AND THE PARK PLACE DRIVEWAY TO CARRY THE
 BACK OF WALK OF THE DRIVEWAY SIDEWALK STRAIGHT THROUGH
 TO INTERSECT THE DEFLECTION OF THE SIDEWALK FROM BEHIND
 THE PARALLEL PARKING SPACES.
  
 B. CROSSWALK STRIPING AND STOP BAR ON PARK PLACE WILL
 NEED TO BE ADJUSTED BASED ON THE LOCATION OF THE NEW
 CURB RAMP.
  
 C. COORDINATE WITH THE ENGINEERING SERVICES DIVISION ON
 THE WIDTH AND LENGTH OF THE PAVEMENT RESTORATION ON
 PARK PLACE, EAST OF THE MEDIAN. THE TRENCH PAVEMENT
 DETAIL SPECIFIES MILLING AND RESURFACING LIMITS.
  
 D. CAN THE CURB ALONG THE BACK OF THE PARALLEL PARKING
 SPACES BE PARALLEL TO THE RIGHT-OF-WAY LINE?
  
 4. PAVING, GRADING AND DRAINAGE PLAN COMMENTS:
 A. CONFIRM GRATE ELEVATIONS FOR ONSITE DRAINAGE
 STRUCTURES. PAVEMENT CROSS SLOPES APPEAR TO BE MORE
 THAN 4% IN SOME AREAS. PROVIDE A SECTION THROUGH THE
 PARKING AREA BEHIND THE BUILDING.
  
 B. BAFFLES MAY NOT BE NEEDED IN MH BASIN #6 UNLESS IT
 HAS A GRATE RATHER THAN A SOLID COVER.
  
 C. GRADE NORTH DRIVEWAY APRON ON PARKER AVENUE TO DRAIN
 AS MUCH OF THE PAVEMENT BACK TO CB #7.
  
 D. CONSIDER CONNECTING PARK PLACE DRAINAGE SYSTEM TO
 THE EXISTING CATCH BASIN ON PARKER AVENUE AND ELIMINATE
 THE PIPE BETWEEN STRUCTURES #2 AND #3.
  
 E. PROVIDE A CROSS SECTION OF PARK PLACE THROUGH THE
 PARALLEL PARKING SPACES.
  
 5. CONCRETE DRIVEWAY APRON DETAIL SHOULD SHOW 6-FOOT
 FLARES ON EACH SIDE - 3 FEET "FLAT" AND 3 FEET OF
 FLARE. SEE CITY'S STANDARD DETAIL GC-6.
  
 6. WHICH ASPHALT PAVEMENT SECTION WILL BE SPECIFIED?
 WILL THE ONSITE PAVEMENT SECTION BE BEEFED UP FOR THE
 WHEEL LOADS OF THE FIRETRUCKS?
  
 7. THE SURVEY SHOWS THE EDGE OF WATER IN THE CANAL TO
 BE ELEVATION 9.0 FT NGVD. IT APPEARS THE LOWER PORTION
 OF ALL THREE SEGMENTS OF THE EXFILTRATION TRENCHES AND
 THE BOTTOM OF THE SLOTTED RCP PIPE IN THE SOUTH TRENCH
 WILL BE LOCATED WITHIN THE WATER TABLE.
  
 8. STORM MANHOLE DETAIL AND TYPICAL CATCH BASIN DETAIL
 SHOULD INDICATE USF240 TYPE D OR G RING AND COVER
 (OAE), DEPENDING ON LOCATION OF MANHOLE. MANHOLES
 OUTSIDE THE RIGHT-OF-WAY WILL NOT HAVE "WEST PALM
 BEACH" EMBOSSED ON THE COVER.
  
 9. CATCH BASINS GRATES SHOULD BE BICYCLE SAFE.
  
 10. VERIFY THE CIVIL DETAILS SHOWN AS "CITY OF WEST
 PALM BEACH - ENGINEERING & PUBLIC WORKS" ARE FROM THE
 CITY.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 PUBLIC WORKS DEPARTMENT
 561-494-1120
 [email protected]
  
  
  
  

Review Stop STORM STORMWATER
Rev No 1 Status F Date 01-13-2015 Cont ID  
Sent By tward Date 01-13-2015 Time 13:30 Rev Time  
Received By tward Date   Time   Sent To  
Notes
2015-01-13 13:36:001. PLOT SITE PLAN (SP-1.0) AT USABLE SCALE. CHECK SCALE
 BAR.
  
 2. ELEVATIONS NEED TO REFERENCE NGVD 1929 (SHEETS
 C3.01, C4.01).
  
 3. CAN ADA RAMP BE LOCATED CLOSER TO THE CORNER?
  
 4. SHOW UTILITIES ON THE ELECTRICAL PLANS.
  
 5. IS THERE A CONNECTION TO AN OFFSITE DRAINAGE SYSTEM?
  
 6. UPDATED FEMA FLOOD INSURANCE RATE MAPS (DRAFT
 VERSION) ARE AVAILABLE.
  
 7. SWPPP EROSION AND SEDIMENT CONTROL PLAN WILL BE
 REQUIRED WITH THE ENGINEERING PERMIT SUBMITTAL.
  
 8. NPDES CONSTRUCTION PERMIT REQUIRED BEFORE START OF
 CONSTRUCTION.
  
 9. PROVIDE WITH THE ENGINEERING PERMIT SUBMITTAL S&S
 CALCULATIONS DEMONSTATING THE STORNMWATER MANAGEMENT
 SYSTEM MEETS SFWMD CRITERIA FOR WATER QUALITY
 TREATMENT.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 PUBLIC WORKS DEPARTMENT
 [email protected]
 561-494-1120
  

Review Stop SURVEY SURVEYING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 01-09-2015 Cont ID  
Sent By vnoel Date 01-09-2015 Time 06:59 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2015-01-09 07:23:031. SURVEY SHOULD ALSO BE A BOUNDARY SURVEY.
 2. THERE IS AN EXISTING LEASE FOR THE ARMORY ART CENTER
 WHICH SHOULD BE SHOWN.
 3. SEPARATE SUBMITTAL FOR SITE/CIVIL REVIEW TO
 ENGINEERING SERVICES IS REQUIRED.
 4. EXISTING GAS LINE WILL NEED TO BE RELOCATED.
 5. PROPOSED DUMPSTER DOES NOT APPEAR TO MEET CITY
 STANDARD.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date 01-14-2015 Cont ID  
Sent By cranford Date 01-14-2015 Time 07:57 Rev Time 0.00
Received By cranford Date 01-14-2015 Time 07:57 Sent To  
Notes
2015-01-14 07:57:27SEE ENG PPRC COMMENTS

Review Stop Z ZONING
Rev No 3 Status P Date 03-13-2015 Cont ID  
Sent By dkittred Date 03-13-2015 Time 09:51 Rev Time 0.00
Received By dkittred Date   Time   Sent To  
Notes
2015-03-13 09:53:543/13/15
  
 APPROVED WITH CONDITIONS OF DAC SPECIAL REVIEW
 (Z15010041) AND PROVIDED A FINAL SURVEY IS PROVIDED FOR
 REVIEW.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 02-19-2015 Cont ID  
Sent By dkittred Date 02-19-2015 Time 14:22 Rev Time 0.00
Received By dkittred Date   Time   Sent To  
Notes
2015-02-19 14:21:59PLANNING AND ZONING COMMENTS:
  
 2/19/2015
  
 ITEMS TO ADDRESS ON SITE PLAN:
  
 1. IN ORDER TO MAINTAIN A CONSISTENT LEVEL SIDEWALK,
 PLEASE REVISE PLANS TO PUSH THE PARK PLACE SIDEWALK
 NORTHWARD AND CREATE A LANDSCAPE STRIP WITH SHADE TREES
 BETWEEN THE PARKING AND SIDEWALK. THE HANDICAP RAMP
 CONNECTION CAN OCCUR IN THE LANDSCAPE STRIP AND THEN
 CONNECT TO THE SIDEWALK WITHOUT CREATING A DIP IN THE
 SIDEWALK TO ACCOMMODATE THE RAMP. ADDITIONALLY, WHEN
 THE SIDEWALK CROSSES THE PARK PLACE DRIVEWAY, IT SHOULD
 BE MAINTAINED AT AN EVEN LEVEL BY BEING CONSTRUCTED ON
 THE NORTHERN SIDE OF THE CURB CUT.
  
 2. SQUARE FOOTAGE USED IN THE CALCULATION (3,162 SQ.
 FT.) FOR THE REQUIRED PARKING APPEARS TO BE TOO SMALL
 AS THE TOTAL BUILDING SIZE IS 11,251 SQ. FT. AND THE
 APPARATUS BAY, WHICH DOES NOT REQUIRE PARKING IS SHOWN
 AS 5,176 SQ. FT. OF THE TOTAL. PLEASE REVIEW AND REVISE
 ACCORDINGLY.
  
 3. ON THE NORTHERN MOST PORTION OF THE SIDEWALK ALONG
 PARKER AVENUE SHOWS THE GUY WIRES FOR THE UTILITY POLE
 WITHIN THE SIDEWALK. CAN THESE GUY WIRES BE RELOCATED
 TO JUST OUTSIDE OF THE SIDEWALK?
  
 4. THE COMMENT RESPONSE LETTER INDICATES THAT PARKING
 LOT AREA HAS BEEN REVISED TO PROVIDE THE 5' BUFFER,
 HOWEVER, THE NORTHERN CORNER OF THE EMPLOYEE PARKING
 AREA IS STILL LESS THAN 5'. OPTIONS TO ADDRESS THIS -
 MOVE THE PARKING SPACES, PUSH OUT THE LANDSCAPE CURBING
 TO BE THE WHEEL STOP WHICH CREATES ADDITIONAL GREEN
 SPACE IN THE CAR OVERHANG, OR REQUEST A VARIANCE.
  
 5. PROPOSED TRANSFORMER APPEARS TO BE OVER THE ARMORY
 ARTS CENTER LEASE LINE? IF THE TRANSFORMER IS ONLY FOR
 THE FIRE STATION, IT WILL NEED TO BE LOCATED OUTSIDE OF
 THE ARMORY ARTS CENTER LEASE LINE. PLEASE CLARIFY.
  
 6. STRIPING DETAIL TO BE REVISED TO INCLUDE 4" STRIPS
 WITH 12" SPACING PER ZLDR SEC. 94-485 STALL PAINTING
 DETAIL. ADDITIONALLY, DETAIL FOR ADA PARALLEL PARKING
 SPACE SHOULD BE INCLUDED.
  
 7. THE WAVE STYLE BICYCLE RACK (SHEET C 6.05) IS NOT
 PERMITTED. PLEASE REVISE TO AN INVERTED 'U', 'A', POST
 AND LOOP OR SIMILAR STYLE.
  
 8. WAITING ON PENDING REVISED SURVEY.
  
 9. RESPONSE INDICATES THAT 'LIMITS OF CLEAR SIGHT' HAVE
 BEEN REVISED ON SHEET L2.01 ON THE PARK PLACE SIDE.
 HOWEVER, THERE WAS NO CHANGE AND THE ORIENTATION IS
 STILL UNCLEAR.
  
  
 LANDSCAPING COMMENTS:
  
 10. PLEASE PROVIDE SCREENING FOR THE FPL TRANSFORMER.
  
 11. ROOT BARRIERS WILL BE REQUIRED FOR THE SATINLEAF
 AND ROYAL PALMS ADJACENT TO THE WATER AND SEWER LINES
 ON THE SOUTH SIDE OF THE BUILDING AND AS NEEDED ALONG
 THE SIDEWALK.
  
 12. PLEASE REVISE THE PLANT LIST TO SHOW THE CORRECT
 PLANT NAME AS CLUSIA ROSEA 'NANA'.
  
 13. PLEASE CORRECT THE FLORIDA FRIENDLY LANDSCAPE
 REQUIREMENT CHART ON SHEET L2.02 SO THE SHRUB AND TREE
 CATEGORIES REFLECT SHRUB AND TREE REFERENCES.
  
  
 ADDITIONAL COMMENTS:
  
 14. A TOTAL OF TWELVE SETS OF PLANS WILL BE REQUIRED
 FOR PROCEEDING TO THE DOWNTOWN ACTION COMMITTEE (DAC).
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 01-13-2015 Cont ID  
Sent By dkittred Date 01-13-2015 Time 09:59 Rev Time  
Received By dkittred Date   Time   Sent To  
Notes
2015-01-13 09:56:14PLANNING AND ZONING COMMENTS: ***FAILED***
  
 1/13/15
  
 ITEMS TO ADDRESS ON SITE PLAN:
  
 1. PARKING STRIPING DETAIL WAS NOT PROVIDED. PLEASE
 PROVIDE STRIPING DETAIL IN ACCORDANCE WITH ZLDR SEC.
 94-485 FOR BOTH 90 DEGREE AND ANGLED PARKING.
  
 2. PLEASE DIMENSION BOTH LENGTH AND WIDTHS OF PARKING
 SPACES ON THE PLAN.
  
 3. VERIFY WITH THE BUILDING DEPT. WHETHER ONE HANDICAP
 SPACE WILL SUFFICE FOR THE PROJECT OR THE SPLIT PARKING
 LOT REQUIRES A HANDICAP SPACE FOR EACH.
  
 4. PROVIDE BICYCLE PARKING CALCULATION (ONE BICYCLE
 PARKING PER EVERY 15 REQUIRED PARKING SPACES) IN
 ACCORDANCE WITH ZLDR SEC. 94-111(I). PLAN INDICATES
 LOCATION FOR BICYCLE PARKING, HOWEVER, THERE WAS NO
 DETAIL PROVIDED FOR THE BICYCLE RACK AND MINIMUM
 SPACING DIMENSIONS. PLEASE PROVIDE (NOTE: RACK SHOULD
 BE AN INVERTED 'U', 'A', POST AND LOOP OR SIMILAR
 STYLE. WAVE STYLE RACKS ARE NOT PERMITTED.)
  
 5. DUMPSTER DETAIL AND DIMENSIONS WERE NOT PROVIDED.
 PLEASE DEMONSTRATE COMPLIANCE WITH ZLDR SEC. 94-444(B).
  
 6. DUMPSTER IS LOCATED WITHIN A GATED AREA. PLEASE
 CONFIRMATION WITH SANITATION THAT THIS WOULD BE
 PERMITTED.
  
 7. INCLUDE 'DO NOT ENTER' SIGNS FOR ONE WAY DRIVES AND
 SHOW STOP SIGN(S) AND STOP BAR(S).
  
 8. WILL THERE BE ANY ISSUES WITH OBTAINING ACCESS TO
 THE ARMORY STORAGE WITH THE ONE-WAY CIRCULATION PATTERN
 AND GATED ACCESS?
  
 9. SURVEY NEEDS TO SHOW PROPERTY LINE AND LEASE LINE
 BOUNDARY OF THE ARMORY ARTS CENTER. ADDITIONAL COMMENTS
 MAY BE GENERATED DEPENDING ON THE LOCATION OF THESE
 LINES.
  
 10. SITE PLAN INDICATES THE APPARATUS BAY AS 'TWO
 STORIES', HOWEVER, THIS AREA IS ONLY ONE STORY. PLEASE
 CORRECT.
  
 11. PER THE ZLDR SEC. 94-109 OPEN SPACE, URBAN ITEM
 (3)(II) AND ZLDR SEC. 94-11(B)(1), PARKING SHALL BE
 PROVIDED IN ACCORDANCE WITH TABLE XV-6. PARKING SHALL
 BE IN COMPLIANCE WITH ITEM #119, PUBLIC SAFETY
 FACILITIES OPERATED BY PUBLIC AGENCIES AT A RATIO OF
 1:500 SQ. FT. PLEASE REVISE CALCULATION ON THE PLANS.
 (NOTE: SQUARE FOOTAGE OF THE APPARATUS BAYS SHOULD NOT
 BE INCLUDED THE SQUARE FOOTAGE USED FOR THE PARKING
 CALCULATION.)
  
 12. PLEASE DEMONSTRATE THAT SOMEONE IN PARKING SPACE
 '12' CAN ADEQUATELY BACK-UP AND EXIT THE PARKING SPACE
 WITH THE VEHICLE ACCESS GATE CLOSED.
  
 13. AN INTERIOR ISLAND WILL NEED TO BE PROVIDED WITHIN
 THE ROW OF 12 PARKING SPACES. PER ZLDR SEC.
 94-113(F)(3), ONE INTERIOR LANDSCAPE ISLAND SHALL BE
 PROVIDED FOR EVERY TEN PARKING SPACES OR FRACTION
 THEREOF. INTERIOR LANDSCAPE ISLANDS SHALL BE AT LEAST
 FIVE FEET WIDE AND SHALL CONTAIN AT LEAST ONE SHADE OR
 FLOWERING TREE.
  
 14. ON SHEET L2.01, HOW DOES THE 'LIMITS OF CLEAR
 SIGHT' WORK ON PARK PLACE SIDE OF THE PROPERTY WORK?
 PLEASE REVIEW.
  
 15. DUE TO THE LARGE CURB-CUT/DRIVEWAY WIDTHS, PLEASE
 PROVIDE TREATMENT FOR CROSSWALKS ACROSS ALL DRIVEWAYS
 TO DELINEATE THE PEDESTRIAN CONNECTION.
  
 16. PROVIDE AN 8' SIDEWALK ALONG PARKER AVENUE.
  
 17. THE PROPOSED DRIVEWAY ALONG PARK PLACE HAS A
 GREATER WIDTH AND CURB CUT THAN WHAT CURRENTLY EXISTS.
 CAN THE WIDTH OF THE PROPOSED DRIVEWAY ALONG PARK PLACE
 BE REDUCED TO MINIMIZE THE DISTANCE A PEDESTRIAN HAS TO
 CROSS THE DRIVEWAY? ADDITIONALLY, MAXIMUM WIDTH OF A
 CURB CUT PER ZLDR SEC. 94-111(O)(3) IS 25'. A VARIANCE
 WILL BE REQUIRED FOR ANY CURB CUT GREATER THAN THIS
 WIDTH.
  
 18. WILL THE ACCESS GATES BE AUTOMATIC WITH KEY CARD OR
 OPEN DURING CERTAIN HOURS? IF AUTOMATIC WITH KEY CARD,
 CAN AN EMERGENCY VEHICLE PULL UP TO THE ACCESS GATE AND
 WAIT FOR THE GATE TO OPEN WITHOUT BLOCKING VEHICLE
 TRAFFIC ON PARK PLACE?
  
 19. RECONFIGURED PARKING OFF OF PARK PLACE WILL REQUIRE
 APPROVAL BY THE CITY'S TRAFFIC ENGINEER. PLANNING HAS
 CONCERN REGARDING MIXING THE ANGLED PARKING WITH 90
 DEGREE HANDICAP PARKING SPACE AS WELL AS THE PROXIMITY
 OF THE HANDICAP SPACE TO THE INTERSECTION. IF THE
 ANGLED PARKING AS SHOWN ON THE PLAN WILL BE PERMITTED,
 WHAT PATH WILL VEHICLE PASSENGERS TAKE TO GET TO THE
 BUILDING AS IT APPEARS THEY WILL BE WALKING THROUGH THE
 LANDSCAPE AREA. STAFF SUGGESTS LOOKING AT PARALLEL
 PARKING IN THIS LOCATION RATHER THAN THE ANGLED OR 90
 DEGREE PARKING.
  
 20. PLANS SHOW KNEE WALLS AND STAIRS ON THE WESTERN AND
 SOUTHERN SIDE OF THE BUILDING. THESE WERE NOT INCLUDED
 IN THE BUILDING ELEVATIONS/MODELS. PLEASE REVISE MODELS
 TO DEPICT THESE ELEMENTS OF THE BUILDING.
  
 21. SITE PLAN PACKET INCLUDES DUPLICATE BUILDING
 ELEVATIONS, ONE WITH BARREL TILE ROOF AND THE OTHER
 WITH STANDING SEAM METAL ROOF. THE BARREL TILE STYLE
 ROOF IS MORE APPROPRIATE TO THE BUILDING DESIGN AND THE
 RECOMMENDED STYLE. PLEASE CLARIFY OR REMOVE ELEVATIONS
 WITH STANDING SEAM METAL ROOF. ADDITIONALLY, PLEASE
 CLARIFY ON THE BARREL TILE STYLE ROOF ELEVATIONS IF THE
 ROOF MATERIAL IS BARREL TILES OR METAL ROOF FABRICATED
 TO LOOK LIKE BARREL TILES.
  
 22. A THREE-DIMENSIONAL RENDERING FROM A BIRD'S EYE
 VIEW WAS SUBMITTED, HOWEVER, YOU WILL ALSO NEED TO
 SUBMIT "STREET-LEVEL THREE-DIMENSIONAL RENDERINGS FOR
 THE PROPOSED DEVELOPMENT AND ALL BUILDINGS ON ADJACENT
 SITES, PUBLIC SPACES AND STREETS TO ILLUSTRATE HOW THE
 NEW BUILDING RELATES TO THE SURROUNDING AREA." (ZLDR
 SEC. 94-54(B)(2))
  
 23. PLEASE REVISE PHOTOMETRIC PLAN TO DEMONSTRATE
 COMPLIANCE WITH ZLDR SEC. 94-113(B) - "ALL BUILDING
 SHALL PROVIDE EXTERIOR LIGHTING EVERY NIGHT FROM DUSK
 TO DAWN TO ILLUMINATE BUILDING ENTRANCES, SIDEWALKS,
 AND PATHS, AT A MINIMUM OF 0.6 FOOTCANDLES AS MEASURED
 AT THE BACK EDGE OF THE CURB AND ONE FOOT ABOVE THE
 SIDEWALK. THIS MEASUREMENT SHALL INCLUDE LIGHT
 EMANATING FROM PUBLIC AND PRIVATE SOURCES. UNSHIELDED
 LIGHT FIXTURES SHALL BE PROHIBITED. THE MAXIMUM MEASURE
 SHALL BE NO MORE THAN 1.0 FOOTCANDLE."
  
 24. LIGHT POLES SHOULD COMPLY WITH NEIGHBORHOOD
 LIGHTING STANDARDS, IF ANY HAVE BEEN ESTABLISHED.
  
  
 LANDSCAPING COMMENTS:
  
 25. THERE ARE OVERHEAD ELECTRIC LINES LOCATED ON THE
 NORTHERN PORTION OF THE SITE. PLEASE REVIEW TREE
 PLACEMENT FOR COMPLIANCE WITH 'RIGHT TREE, RIGHT PLACE'
 STANDARDS TO AVOID FUTURE TREE GROWTH CONFLICTING WITH
 THE OVERHEAD POWER LINES.
  
 26. PLEASE INDICATE ON LANDSCAPE PLAN THAT PROPOSED
 TREES WILL HAVE A MINIMUM 5' CLEAR TRUNK (ZLDR SEC.
 94-445(4)(A)).
  
 27. A MINIMUM 5' LANDSCAPE BUFFER IN ACCORDANCE WITH
 94-113(F)(1) SHALL BE PROVIDED AROUND THE PARKING AREA.
 PLEASE REVIEW NORTHERN LIMITS OF THE EMPLOYEE PARKING
 AREA WHICH DOES NOT APPEAR TO MEET THE 5' BUFFER.
 BUFFER SHOULD BE MEASURED FROM THE ARMORY ARTS CENTER
 LEASE LINE. ADDITIONALLY, NEW ARECA PALMS SHOULD BE
 PROVIDED TO FILL IN THE GAPS BETWEEN THE EXISTING ARECA
 PALMS ALONG THE BUFFER AREA.
  
 28. FOR THE TREE MITIGATION REQUIREMENTS YOU MAY COUNT
 REQUIRED NEW TREES AS PART OF YOUR REPLACEMENT NUMBERS.
 PLEASE REVISE TREE REPLACEMENT CHART ON L2.02.
  
 29. CONSIDER A MORE FREEFORM DESIGN OF THE LANDSCAPING
 IN THE NORTHERN MOST LANDSCAPE AREA TO ALLOW FOR A
 VISUAL CONNECTION WITH THE PARK.
  
  
 GENERAL COMMENTS:
  
 30. CONSIDER ALIGNING THE NORTHERN EXIT ON PARKER
 AVENUE WITH CAROLINE STREET.
  
 31. THE DEVELOPMENT IS SUBJECT TO SPECIAL REVIEW AND
 APPROVAL BY DAC WILL BE REQUIRED PURSUANT TO ZLDR SEC.
 94-54(B)(C).
  
 32. ALTHOUGH NONE ARE BEING PROPOSED AT THIS TIME, ANY
 PROPOSED SIGNAGE SHALL NOT BE INTERNALLY ILLUMINATED
 BOX SIGNS.
  
 33. PLEASE KEEP IN MIND THAT DURING BUILDING
 PERMITTING, THE APPLICABILITY OF THE REQUEST WILL BE
 REVIEWED FOR COMPLIANCE WITH THE CITY'S ART IN PUBLIC
 PLACES REGULATIONS. VERTICAL CONSTRUCTION EXCEEDING
 $500,000 WILL BE REQUIRED TO PROVIDE ART OR MAKE A
 CONTRIBUTION TO THE ART IN PUBLIC PLACES FUND AS
 SPECIFIED IN THE CITY'S CODE OF ORDINANCES ARTICLE V.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  

  Print


Account Summary | Usage Policy | Privacy Policy