Plan Review Details - Project Z14120013
Plan Review Stops For Project Z14120013
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 01-14-2015 Cont ID  
Sent By rbrown Date 01-14-2015 Time 11:14 Rev Time 0.00
Received By rbrown Date 01-14-2015 Time 11:13 Sent To  
Notes
2015-01-14 11:33:28DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. FIRE SEPARATION DISTANCE. PER SECTION 702 AND 705 OF
 FLORIDA BUILDING CODE, THE MINIMUM DISTANCE OF A
 BUILDING TO THE PROPERTY LINE AND THE PERCENTAGE OF
 ONENINGS ALLOWED IN A WALL FACING THE PROPERTY LINE CAN
 BE MEASURED TO THE CENTER LINE OF THE RIGHT-OF-WAY. THE
 CODE COMPLIANCE OF CURRENT BUILDINGS, AND ANY FUTURE
 BUILDINGS, NEAR THE REAR PROPERTY LINE OF THE
 PROPERTIES FROM 411 MAYFLOWER ROAD THROUGH 509
 MAYFLOWER RD, MAY BE NEGATIVELY IMPACTED IF THE ALLEY
 IS NO LONGER A RIGHT-OF-WAY. FROM THE BUILDING CODE
 PERSPECTIVE, THE PROPOSED PURCHASE OF THE ALLEY WOULD
 EFFECTIVELY MOVE THE PROPERTY LINE, AS DEFINED BY
 FLORIDA BUILDING CODE, APPROXIMATELY 8.5 FEET CLOSER TO
 THE BUILDINGS ON THOSE PROPERTIES. THE OWNERS OF THE
 AFFECTED PROPERTIES, AT 411 MAYFLOWER ROAD THROUGH 509
 MAYFLOWER RD, SHOULD BE MADE AWARE OF THIS ISSUE AND
 ACKNOWLEDGE THEIR AGREEMENT.
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  
2015-01-12 11:58:55 
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 01-14-2015 Cont ID  
Sent By cranford Date 01-14-2015 Time 08:47 Rev Time 0.00
Received By cranford Date 01-14-2015 Time 08:44 Sent To  
Notes
2015-01-14 08:47:25ALLEY APPEARS TO BE IN USE BY ADJACENT PROPERTY OWNERS
 AND FPL. LIMITED ACCESS PETITION, UTILITY CLEARANCE
 LETTER, AND WRITTEN CONFIRMATION FROM PUBLIC UTILITIES
 CONFIRMING THAT THEY DO NOT OBJECT TO CLOSURE WAS NOT
 INCLUDED IN PACKAGE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 01-08-2015 Cont ID  
Sent By pleduc Date 01-08-2015 Time   Rev Time 0.00
Received By pleduc Date 01-08-2015 Time 16:50 Sent To  
Notes
2015-01-08 16:52:28THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED.
  
 FIRE PREVENTION DOES NOT HAVE AN OBJECTION TO THE
 PROPOSED PENDING THE LOCATION AND/OR RELOCATION OF ANY
 FIRE LINES OR FIRE HYDRANTS WITHIN THE PROPOSED
 BOUNDARIES.
  

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PU PUBLIC UTILITIES
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 1 Status P Date 01-13-2015 Cont ID  
Sent By tward Date 01-13-2015 Time 13:37 Rev Time 0.00
Received By tward Date   Time   Sent To  
Notes
2015-01-13 13:38:301. LOTS 16 AND 18 APPEAR TO BE MISLABELED ON THE
 TOPOGRAPHIC SURVEY.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 PUBLIC WORKS DEPARTMENT
 [email protected]
 561-494-1120
  

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 01-09-2015 Cont ID  
Sent By vnoel Date 01-09-2015 Time 07:32 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2015-01-09 08:11:431. PROPERTY WILL NEED TO BE APPRAISED. CITY WILL OBTAIN
 COST TO BE PAID FOR BY APPLICANT.
 2. NOTE: THE APPRAISAL WILL BE AN "ACROSS THE FENCE"
 EVALUATION IN THAT VALUATION
 WILL BE BASED ON CURRENT SQUARE FOOT PRICES, NOT SOLELY
 SIZE AND SHAPE OF STAND-ALONE PARCEL.
 3. THERE IS A "1 FOOT RESERVED" PARCEL INCLUDED IN
 SKETCHES. WE ARE HAVING THE LAW DEPT. REVIEW FOR
 ABILITY TO VACATE.
 4. AS THE PLAT CONTAINS REVERSIONARY RIGHTS OF THE
 ALLEY, APPLICANT MUST PROVIDE INFORMATION THAT NO
 ENFORCEMENT HAS BEEN INSTITUTED.(SECTION 177.085(2)
 F.S.)

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 01-12-2015 Cont ID  
Sent By dkittred Date 01-12-2015 Time 11:56 Rev Time 0.00
Received By dkittred Date   Time   Sent To  
Notes
2015-01-12 12:03:17PLANNING AND ZONING COMMENTS: 1/12/14
  
 ITEMS TO ADDRESS WITH APPLICATION SUBMITTAL:
  
 1. PLEASE PROVIDE A COPY OF THE 400 RADIUS MAP THAT
 WOULD HAVE BEEN PROVIDED BY THE PROPERTY APPRAISER AT
 THE TIME OF PRINTING THE SURROUNDING PROPERTY OWNER
 ADDRESSES.
  
 2. THERE WERE NO UTILITY LETTERS PROVIDED IN THE
 SUBMITTAL. PLEASE OBTAIN AND SUBMIT THE UTILITY LETTERS
 IN ACCORDANCE WITH ITEMS NO. 13 AND 14 IN THE
 APPLICATION PACKET. SURVEY SHOWS OVERHEAD LINES WITHIN
 THE ALLEY SO AN UTILITY EASEMENT OF SOME CAPACITY WILL
 BE REQUIRED DEPENDING ON THE RESPONSES RECEIVED FROM
 THE VARIOUS UTILITY PROVIDERS.
  
 3. WHAT IS PHILIP ESXLUND'S RELATIONSHIP TO 444 BUNKER
 ROAD? OATH OF PETITIONER STATES HE IS THE
 PRESIDENT/CHAIRMAN OF THE SUBJECT PROPERTY, BUT I WAS
 NOT ABLE TO FIND A CONNECTION. PLEASE CLARIFY AND/OR
 PROVIDE DOCUMENTATION AS NECESSARY.
  
 4. THERE WERE NO SIGNED AND SEALED SURVEYS IN THE
 SUBMITTAL. PLEASE PROVIDE A MINIMUM OF THREE SETS OF
 SIGNED AND SEALED SURVEYS.
  
 5. PLEASE SUBMIT COPIES OF ALL SURVEYS IN ELECTRONIC
 FORMAT - PNG FILE TYPE. YOU MAY SEND THEM VIA EMAIL.
  
 6. IS THERE ANY TRASH COLLECTION TAKING PLACE ALONG THE
 ALLEY ON THE WEST SIDE OF WEBSTER AVENUE?
  
  
  
 GENERAL COMMENTS:
  
 7. ARE THERE ANY PRELIMINARY PLANS FOR HOW THE
 REQUESTED AREA TO BE ABANDONED WILL BE USED? THE
 APPLICATION STATES THAT THE REASON FOR THE ABANDONMENT
 OF THE ALLEY IS TO IMPROVE THE SPACE AND ADD
 LANDSCAPING.
  
 8. HAVE YOU SPOKEN WITH ANY OF THE PROPERTY OWNERS THAT
 ABUT THE ALLEY OR COULD BE POTENTIAL USERS OF THE
 ALLEY? ARE YOU ABLE TO PROVIDE ANY LETTERS OF NEIGHBOR
 SUPPORT?
  
 9. PLEASE BE AWARE THE COST OF THE APPRAISAL FOR THE
 RIGHT-OF-WAY REQUESTED TO BE ABANDONED WILL BE $1,800.
 THE FEE WILL BE COLLECTED AND APPRAISAL ORDERED AFTER A
 DETERMINATION HAS BEEN MADE REGARDING THE LOCATION OF
 ANY UTILITY EASEMENTS REQUIRED FOR THE REQUEST.
  
 10. IN REVIEW OF THE INFORMATION SUBMITTED, PLANNING
 STAFF IS NOT IN SUPPORT OF ABANDONMENT OF THE PORTION
 OF THE ALLEY TO THE WEST OF WEBSTER AVENUE WHICH WOULD
 CREATE DEAD-END ALLEY RIGHT-OF-WAY.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  