Plan Review Details - Project Z14110037
Plan Review Stops For Project Z14110037
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 12-10-2014 Cont ID  
Sent By rbrown Date 12-10-2014 Time 11:35 Rev Time 0.00
Received By rbrown Date 12-10-2014 Time 11:35 Sent To  
Notes
2014-12-10 11:41:04DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR PERMITTING.
  
 2. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL
 SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS
 WILL BE THE SAME AS THE OTHER BUILDINGS AT THE PALM
 BEACH OUTLET MALL, OR WILL STILL BE IN ACCORDANCE WITH
 THE HEIGHT, AREA AND OCCUPANCY LIMITATIONS IN CHAPTER 5
 OF THE FLORIDA BUILDING CODE
  
 3. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH
 ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND
 OPENING PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 OF
 THE FLORIDA BUILDING CODE SHALL BE VERIFIED.
  
 4. ALL APPLICABLE PERMITS AND SUB-PERMITS MUST BE
 OBTAINED BEFORE COMMENCING THE WORK. SEPARATE PERMITS,
 PLANS AND FEES, ARE REQUIRED FOR SWIMMING POOLS AND
 SPAS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, FIRE
 SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, GREASE
 INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, SITE
 IRRIGATION, ETC.
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 12-08-2014 Cont ID  
Sent By cranford Date 12-08-2014 Time 10:47 Rev Time 0.00
Received By cranford Date 12-08-2014 Time 10:47 Sent To  
Notes
2014-12-08 10:47:26PUBLIC WORKS DEPT.
  
 THIS IS A CONCEPTUAL LEVEL REVIEW. TECHNICAL DETAILS OF
 THE WATER, SEWER, STORMWATER, TRAFFIC CIRCULATION, AND
 SOLID WASTE COLLECTION WILL BE REVIEWED AS PART PART OF
 THE ENGINEERING DEVELOPMENT APPROVAL AND BUILDING
 PERMIT APPLICATION PROCESSES. THE ENGINEERING
 DEVELOPMENT APPROVAL APPLICATION FORMS CAN BE
 DOWNLOADED AT
 HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/
  
 1. INDICATE THE LOCATIONS OF THE DUMPSTERS INTENDED TO
 BE SERVICE BY THE CITY OF WEST PALM BEACH SANITATION
 DEPARTMENT. DUMPSTERS MUST BE EASILY ACCESSIBLE BY THE
 CITY EQUIPMENT AND MANPOWER.
 2. INCLUDE AN ESTIMATE OF THE SOLID WASTE YARDAGE
 ANTICIPATED TO BE GENERATED BY THE EXPANDED FACILITY.
  
 PLEASE NOTE, A MODIFICATION OF THE EXISTING ENGINEERING
 DEVELOPMENT APPROVAL E12080012 WILL BE REQUIRED PRIOR
 TO START OF CONSTRUCTION.
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 [email protected]
 561-494-1098
  
 BRIAN COLLINS, P.E.
 TRAFFIC ENGINEER
 [email protected]
 561-494-1076
  
 VINCE NOEL, P.S.M.
 SURVEY / REAL ESTATE SUPERVISOR
 [email protected]
 561-494-1116
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 12-04-2014 Cont ID  
Sent By pleduc Date 12-04-2014 Time   Rev Time 0.00
Received By pleduc Date 12-04-2014 Time 14:38 Sent To  
Notes
2014-12-04 15:08:46THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. TRASH AND DEBRIS IS TO BE REMOVED FROM THE SITE
 DAILY OR MORE OFTEN TO REDUCE THE ACCUMULATION OF
 POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEMIS REQUIRED
 FOR THIS PROJECT. SEPARATE SHOP DRAWINGS, ARE REQUIRED
 TO BE SUBMITTED, REVIEWED AND APPROVED BY THE FIRE
 PREVENTION BUREAU PRIOR TO ANY INSTALLATION.
  
 6. A MONITORED FIRE ALARM SYSTEM IS REQUIRED FOR THIS
 PROJECT. SEPARATE SHOP DRAWINGS, ARE REQUIRED TO BE
 SUBMITTED, REVIEWED AND APPROVED BY THE FIRE PREVENTION
 BUREAU PRIOR TO ANY INSTALLATION.
  
 7. ALL PORTABLE FIRE EXTINGUISHERS LOCATIONS SHALL BE
 CLEARLY IDENTIFIED AND INDICATED ON THE PLAN.
  
 8. COMPLETE LIFE SAFETY PLANS FOR THE BUILDING SHALL BE
 PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, DEAD-END CORRIDORS AND ALL FIRE SAFETY
 EQUIPMENT.
  
 9. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR EACH
 BUILDING.
  
 10. ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR THIS
 DEVELOPMENT SHALL BE CLEARLY INDICATED AND IDENTIFIED
 ON THE PLAN. THE FIRE HYDRANT AND FDC'S FOR THIS
 PROJECT SHALL BE CLOSELY COORDINATED WITH THE BUREAU OF
 FIRE PREVENTION. IT WILL RECOMMEND THAT THE PROPOSED
 NEW HYDRANT LOCATIONS BE MOVED CLOSER TO THE BUILDING
 IN AN AGREEABLE LOCATION.
  
 11. NOTICE IS REQUIRED FOR STRUCTURES WITH LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR
 ANY MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR
 MORE WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED
 WITH AN APPROVED SYMBOL. THE APPROVED SYMBOL SHALL BE
 PLACED WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY
 DOOR.
  
 12. NO EXIT DOOR SHALL BE LOCKED FROM THE EGRESS SIDE.
 ANY AND ALL LOCKING MECHANISMS SHALL BE COMPLAINT WITH
 CHAPTER 7 OF THE FLORIDA FIRE PREVENTION CODE AND
 PRE-APPROVED (PRIOR TO INSTALLATION) BY THE BUREAU OF
 FIRE PREVENTION. CLOSE COORDINATION WITH THE BUREAU OF
 FIRE PREVENTION IS STRONGLY ENCOURAGED TO AVOID
 MISUNDERSTANDINGS, MISINTERPRETATIONS AND DELAYS
 RELATED TO EGRESS REQUIREMENTS.
  
 13. FOR THE FRONT DOOR OF EACH SPACE: PER SECTION
 7.2.1.5.9, THE LOCK/LATCH RELEASING MECHANISM ON ALL
 DOORS SHALL OPEN THE DOOR WITH NOT MORE THAN ONE
 RELEASING OPERATION. THE RELEASING MECHANISM SHALL HAVE
 AN OBVIOUS METHOD OF OPERATION THAT IS READILY OPERATED
 UNDER ALL LIGHTING CONDITIONS. THE RELEASING DEVICE
 SHOULD BE CAPABLE OF BEING OPERATED WITH ONE HAND AND
 SHOULD NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR
 TWISTING OF THE WRIST TO OPERATE.
  
 A THUMB TURN LOCK MAY BE PERMITTED ON EACH MAIN ENTRY
 DOOR(S); HOWEVER, THE THUMB TURN LOCK SHALL BE EQUIPPED
 WITH A LOCK/UNLOCK INDICATOR WINDOW WITH SIGNAGE
 STATING THE DOOR(S) IS TO REMAIN UNLOCKED DURING
 BUSINESS HOURS.
  
 14. ALL LIFE SAFETY SYSTEMS SHALL BE CONSISTENT WITH
 AND FULLY INTERGRATED INTO THE OUTLET MALL'S CURRENT
 LIFE SAFETY SYSTEMS.
  
  

Review Stop L LANDSCAPING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 1 Status F Date 12-08-2014 Cont ID  
Sent By cranford Date 12-08-2014 Time 10:48 Rev Time 0.00
Received By cranford Date 12-08-2014 Time 10:48 Sent To  
Notes
2014-12-08 10:48:19SEE ENG PPRC COMMENTS.

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 12-08-2014 Cont ID  
Sent By cranford Date 12-08-2014 Time 10:49 Rev Time 0.00
Received By cranford Date 12-08-2014 Time 10:48 Sent To  
Notes
2014-12-08 10:49:03SEE ENG PPRC COMMENTS.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date 12-08-2014 Cont ID  
Sent By cranford Date 12-08-2014 Time 10:49 Rev Time 0.00
Received By cranford Date 12-08-2014 Time 10:49 Sent To  
Notes
2014-12-08 10:49:32SEE ENG PPRC COMMENTS.

Review Stop Z ZONING
Rev No 2 Status P Date 02-02-2015 Cont ID  
Sent By eschneid Date 02-02-2015 Time 19:19 Rev Time 0.00
Received By eschneid Date 02-02-2015 Time 19:18 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 12-10-2014 Cont ID  
Sent By eschneid Date 12-10-2014 Time 10:16 Rev Time 8.00
Received By eschneid Date 12-10-2014 Time 10:16 Sent To  
Notes
2014-12-10 10:17:18PB 891AA
 PALM BEACH OUTLETS PBA 2B REVISIONS
 1801 PALM BEACH LAKES
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FIVE
 (5) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS
 FROM THE DATE OF THE PPRC MEETING (BY FEBRUARY 10,
 2015), THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY
 FURTHER ACTION SHALL REQUIRE A NEW DEVELOPMENT
 APPLICATION.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($60).
  
 1) THE SITE DATA TABLE SHALL BE AMENDED AT PROPOSED
 GROSS FLOOR AREA TO NOT STATE "THIS APPLICATION". FOR
 FUTURE REVIEW CLARITY, IT SHOULD LOOK LIKE:
  
 GROSS FLOOR AREA: 818,605 SF (PH1)
  932,397 SF (PH1 + PH2)
  
 THIS SHOULD ALSO BE REFLECTED IN THE CHART. NOTE: IT IS
 VERY CLEAR HOW MUCH SQUARE FOOTAGE IN EACH PHASE ON THE
 MASTER PLAN PBA CHART.
  
 2) PROVIDE THE OVERALL FINAL SITE PLAN SHOWING THE
 PHASE 2 BUILDOUT. THIS SHOULD BE A STANDALONE FSP-1.1,
 NOT THE BUILDINGS GHOSTED ON TOP OF THE CURRENT PARKING
 LAYOUT AS SHOWN ON FSP-1.
  
 3) TWO ADA SPACES APPEAR TO HAVE BEEN REMOVED WITHOUT
 THE CORRESPONDING UPDATE OF THE DATA TABLE.
  
 4) THE UTILITY LAYERS AND SOME OF THE INTERIOR CORRIDOR
 LAYERS DO NOT APPEAR TO HAVE BEEN TURNED ON FOR FSP-2.1
 AND 3.1. THE LAYERS SHOWN ON THE PREVIOUSLY APPROVED
 PLANS SHALL BE INCLUDED WITH THE NEW PLANS.
  
 5) THE BICYCLE RACK SOUTHEAST OF THE VALET STAND SHALL
 BE 11.5 FEET IN WIDTH.
  
 6) A PEDESTRIAN CROSS WALK SHALL BE INSTALLED ACROSS
 THE NARROW PORTION OF THE DRIVE AISLE SOUTH OF THE
 VALET STAND TO PROVIDE MORE OPTIONS TO THE WALKWAY
 NETWORK. THERE IS A CROSSING GENERALLY SHOWN IN THIS
 LOCATION ON THE CURRENTLY APPROVED PHASE 2 PLAN.
  
 7) SIGNS NOTIFYING DRIVERS OF THE PEDESTRIAN CROSSINGS
 SHALL BE INSTALLED FOR THE CROSSWALKS ADJACENT TO THE
 VALET STAND.
  
 8) THERE ARE UNSCREENED DUMPSTERS THAT ARE LOCATED
 WITHIN THE BUILDING J-1 SERVICE COURT. THESE DUMPSTERS
 SHALL EITHER BE LOCATED WITHIN AN ENCLOSURE THAT IS
 SHOWN ON THE SITE PLAN, OR BE REMOVED. ALTERNATIVELY, A
 SCREEN GATE MAY BE INSTALLED TO COVER THE ENTRANCE TO
 THE SERVICE AREA.
  
 9) THE SERVICE COURT FOR THE NEW PHASE 2 BUILDING NO
 LONGER SHOWS THE FOUNDATION PLANTING EXTENDING FIVE (5)
 FEET PAST THE SERVICE COURT OPENING AS REQUIRED BY THE
 DESIGN GUIDELINES. THIS IS NOT SHOWN ON THE SOUTH SIDE
 OF THE OPENING.
  
 10) THE COMPACTOR SHOWN IN THE SERVICE COURT FOR THE
 NEW PHASE 2 BUILDING IS NO LONGER SCREENED BY THE
 SERVICE COURT WALL.
  
 11) PROVIDE A REVISED OVERALL LANDSCAPE PLAN SHOWING
 PHASE 2 (SHEET LP-1.1) AND SHEETS LP-2.1 AND 2.3 WITH
 ALL THE EXISTING AND PROPOSED LANDSCAPE. THESE WILL BE
 THE PLANS OF RECORD FOR THE ULTIMATE BUILD-OUT OF THE
 PB OUTLETS. STAFF WILL NOT ACCEPT THE NEED TO MULTIPLE
 DOCUMENTS TO PIECE TOGETHER THE FINAL APPROVED
 LANDSCAPE.
  
 12) PLEASE CONSIDER PLANNING SOME MORE TREES ALONG THE
 NORTH SIDE OF THE NEW BUILDING AND THE J-3 SERVICE
 COURT TO SOFTEN THE LONG FACADES.
  
 13) A NEW BICYCLE RACK (NO DIMENSIONS) IS SHOWN EAST OF
 THE NEW BUS DROP OFF. THE SITE PLAN STILL SHOWS THE
 EXISTING BICYCLE RACK BETWEEN THE NEW BUS DROP OFF
 CANOPIES. WHILE STAFF SUPPORTS THE PROVISION OF MORE
 BICYCLE PARKING, IS IT THE INTENT TO HAVE BOTH RACKS?
 THE ARCHITECTURAL SITE PLAN DOES NOT SHOW EITHER RACK.
  
 14) BASED ON STAFF PEDESTRIAN OBSERVATION AND
 EXPERIENCE, STAFF RECOMMENDS THAT STEPPING STONE PATHS
 (OR EVEN FULL SIDEWALKS) BE INSTALLED LEADING FROM THE
 EXECUTIVE CENTER ENTRY ROAD SIDEWALK TO THE ADJACENT
 PARKING AREAS (STAFF HAS THIS ANNOTATED ON A PLAN TO
 SHOW EXAMPLES).
  
 15) PLEASE UPDATE PLANS TO REFERENCE THE NEW BUILDING
 AS J-11.
  

  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved