Plan Review Details - Project Z14100024
Plan Review Stops For Project Z14100024
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 11-12-2014 Cont ID  
Sent By rbrown Date 11-12-2014 Time 11:18 Rev Time 0.00
Received By rbrown Date 11-12-2014 Time 11:18 Sent To  
Notes
2014-11-12 11:35:57DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR PERMITTING.
  
 2. ACCESSIBLE PARKNG SPACE FOR THE MAIL BOX AREA. THE
 ACCESSIBLE PARKING SPACE IS CURRENTLY SHOWN REMOTE FROM
 THE MAIL BOXES ON THE OPPOSITE SIDE OF THE PARKING LOT.
 PER SECTION 208.3 OF FLORIDA ACCESSIBILITY CODE
 ACCESSIBLE PARKING SPACES ARE TO BE LOCATED ON THE
 SHORTEST POSSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING
 TO AN ACCESSIBLE ENTRANCE FOR EACH BUILDING OR
 FACILITY.
  
 3. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL
 SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS
 WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND
 OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA
 BUILDING CODE
  
 4. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH
 ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND
 OPENING PROTECTIVE REQUIREMENTS FOR ONE AND TWO FAMILY
 DWELLINGS, AND TOWNHOUSES IN SECTION R302 OF FLORIDA
 BUILDING CODE (RESIDENTIAL) WILL BE VERIFIED.
  
 5. ALL APPLICABLE PERMITS AND SUB-PERMITS MUST BE
 OBTAINED BEFORE COMMENCING THE WORK. SEPARATE PERMITS,
 PLANS AND FEES, ARE REQUIRED FOR SWIMMING POOLS AND
 SPAS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, FIRE
 SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, GREASE
 INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, SITE
 IRRIGATION, ETC.
  
 6. FOR STREET ADDRESSING CONTACT SCOTT ALEF, GIS
 SUPPORT SPECIALIST, AT (561) 494 1094, OR BY EMAIL:
 [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status P Date 11-12-2014 Cont ID  
Sent By cranford Date 11-12-2014 Time 11:37 Rev Time 0.00
Received By cranford Date 11-12-2014 Time 11:37 Sent To  
Notes
2014-11-12 11:37:39PUBLIC WORKS DEPT.
 LAND DEVELOPMENT
  
 THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION DETAILS
 WILL BE REVIEWED AS PART OF THE ENGINEERING DEVELOPMENT
 APPROVAL AND BUILDING PERMIT APPLICATION PROCESSES. THE
 ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS CAN
 BE DOWNLOADED AT
 HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/
  
 1. ADD THE EQUIVALENT OF ONE PARKING SPACE AT THE
 TERMINUS OF THE WESTERN DEAD-END AISLES WHICH SHALL BE
 STRIPED AS A DEDICATED PULL-IN AREA FOR TURNING AROUND.
 [CODE SECTION 94-111(2)]
  
 2. PLEASE SUBMIT A SIGNED AND SEALED COPY OF THE
 SURVEY.
  
 3. INDICATE ON THE PLANS WHICH PORTIONS OF THE POTABLE
 WATER, SANITARY SEWER, AND STORM WATER SYSTEM ARE
 INTENDED TO BE PUBLICALLY OWNED AND WHICH PORTIONS WILL
 BE MAINTAINED BY THE APPLICANT.
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
 [email protected]
 561-494-1098 (OFFICE)
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 11-10-2014 Cont ID  
Sent By pleduc Date 11-10-2014 Time   Rev Time 0.00
Received By pleduc Date 11-10-2014 Time 13:47 Sent To  
Notes
2014-11-10 14:50:46THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT; HOWEVER, THE FOLLOWING ARE THE NOTED
 CONCERNS.
  
 ALL CONSTRUCTION SHALL COMPLY WITH NFPA 241
  
 SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM ALL
 ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. ADDRESS
 NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND AND SHALL
 NOT BE LESS THAN SIX (6) INCHES IN HEIGHT WITH A ONE
 (1) INCH STROKE FOR ALL BUILDINGS.
  
 TRASH AND DEBRIS IS TO BE REMOVED FROM THE SITE DAILY
 OR MORE OFTEN TO REDUCE THE ACCUMULATION OF POTENTIAL
 LIFE AND FIRE SAFETY HAZARDS.
  
 THE PARKING CONFIGURATION IS INCONSISTENT WITH PHASE I.
 THE PROPOSED CONFIGURATION IS A HINDRANCE IN THE EVENT
 OF EMERGENCY ACCESS BOTH FIRE AND EMS. IT IS DIFFICULT
 TO MANEUVER A STRCHER BETWEEN CARS AS THEY ARE PARKED
 ACCROSS THE ENTIRE PARKING AREA. IN THE SAME MANNER,
 FIRE OPERATIONS ARE COMPROMSED WHEN PULLING HOSE AND
 TOOLS BETWEEN CARS IN THE EVENT OF A FIRE.
 ADDITIONALLY, FIRE HYDRANT ACCESS CAN BE DIFFICULT
 UNLESS POSTIONED STRATEGICALLY TO REDUCE OBSTACLES,
 BARRIERS AND DELAYS, AS WELL AS, PROTECTION FROM
 TRAFFIC AND PARKING.
  
 FIRE HYDRANT LOCATIONS WERE NOT CLEARLY INDICATED, BUT
 THEY SHOULD BE CONSISTENT WITHPHASE I AND SHALL BEING
 APPROVED BY THE FIRE PREVENTION BUREAU.
  
 ALL UNDERGROUND WATER LINES CONNECTING FIRE HYDRANTS
 SHALL BE CONSIDERED FIRE LINES AND INSTALLED AND
 INSPECTED AS SUCH.
  
 ALL BUILDINGS APPEAR TO BE APARTMENTS; HOWEVER, THE
 TERM TOWNHOUSES IS BEING USED. FURTHER DETAIL OF THE
 CONSTRUCTION AND SEPARATION OF THE UNITS IS REQUIRED.
 ALL APARTMENT BUILDINGS SHALL COMPLY WITH THE FLORIDA
 FIRE PREVENTION CODE, 2010 EDITION, THE LIFE SAFETY
 CODE, 2009 EDITION, INCLUDING MORE SPECIFICALLY,
 CHAPTER 30, NEW APARTMENTS.
  
 THE CLUBHOUSE IS A SEPARATE STRUCTURE AND OCCUPANCY AND
 MAY REQUIRE A SEPARATE BUILDING PERMIT. COMMUNICATON
 WITH THE BUILDING DEPARTMENT IS STRONGLY ENCOURAGED.
  
 NOTICE IS REQUIRED FOR STRUCTURES WITH LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR
 ANY MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR
 MORE WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED
 WITH AN APPROVED SYMBOL. THE APPROVED SYMBOL SHALL BE
 PLACED WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY
 DOOR.
  
  
  
  
  

Review Stop L LANDSCAPING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 2 Status P Date 12-16-2014 Cont ID  
Sent By tward Date 12-16-2014 Time 09:25 Rev Time 0.00
Received By tward Date   Time   Sent To  
Notes
2014-12-16 09:37:221. REVISE NOTE 4 ON SHEETS C-5 THROUGH C-10 TO READ
 "NATIONAL GEODETIC" INSTEAD OF "NORTH AMERICAN" FOR
 NGVD1929.
  
 2. PROVIDE DROP OFF BARRIER PROTECTION AT TOP OF
 RETAINING WALL OF DRY DETENTION AREAS.
  
 3. DRY DETENTION AREAS ARE SHOWN TO HAVE 3:1 SIDE
 SLOPES. IT IS DIFFICULT TO MAINTAIN (MOW) SLOPES
 STEEPER THAN 4:1.
  
  

Review Stop STORM STORMWATER
Rev No 1 Status F Date 11-10-2014 Cont ID  
Sent By tward Date 11-10-2014 Time 10:43 Rev Time  
Received By tward Date   Time   Sent To  
Notes
2014-11-10 11:49:191. CONFIRM STORM PIPES BETWEEN STRUCTURE 4.0 AND LAKE
 AND BETWEEN STRUCTURE 10.0 AND LAKE ARE TO BE
 CONSTRUCTED 23 FEET DEEP (INVERT ELEV. = -5.25). WHY SO
 DEEP?
  
 2. RECOMMEND USING MINIMUM 15" DIAMETER STORM PIPE FOR
 LONG TERM MAINTENANCE CONSIDERATION.
  
 3. SPOT GRADES CUTOFF ON LEFT SIDE OF SHEET PGD-3.
  
 4. EXPLAIN HOW DRY DETENTION AREAS WILL RECEIVE
 STORMWATER RUNOFF.
  
 5. PROVIDE TYPICAL SECTIONS FOR LAKE AND DRY DETENTION
 AREAS.
  
 6. WILL THE REAR OF PHASE 1 BUILDINGS 37-44 AND 46-52
 DRAIN TO THE PHASE 2 DRAINAGE SYSTEM?
  
 7. LABELS CUTOFF ON LEFT SIDE OF SHEET WS-3.
  
 8. CONFIRM WITH FPL THE MINIMUM CLEARANCE FOR
 CONSTRUCTING NEAR THEIR POWER POLES AND GUY WIRE
 ANCHORS.
  
 9. FAC 62-555, MINIMUM 6' HORIZONTAL SEPARATION
 REQUIRED BETWEEN OUTSIDE WATER MAINS AND SANITARY FORCE
 MAINS IS 6 FEET. IT APPEARS THE CENTER TO CENTER
 SEPARATION BETWEEN THE PROPOSED 6" FM AND 20" WATER
 MAIN IS 5 FEET AS THE FM IS DEFLECTED AROUND THE POWER
 POLES.
  
 10. PRIVATE OR PUBLIC FORCE MAIN?
  
 11. SHOW ALL PROPOSED UTILITIES ON THE PHASE 2
 LANDSCAPE PLANS. STORMWATER PIPES TO LAKE AND DRY
 DETENTION AREAS ARE NOT SHOWN.
  
 12. NO LANDSCAPING PROPOSED AROUND THE LAKE?
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPT.
 561-494-1120

Review Stop SURVEY SURVEYING
Rev No 2 Status P Date 12-23-2014 Cont ID  
Sent By vnoel Date 12-23-2014 Time 09:14 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2014-12-23 09:18:05PASSED WITH CONDITION OF REPLAT AND UTILITY MAINTENANCE
 AGREEMENT.

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 11-12-2014 Cont ID  
Sent By vnoel Date 11-12-2014 Time 07:20 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2014-11-12 07:27:171. RE-PLAT WILL BE REQUIRED.
 2. SITE/CIVIL PLANS REQUIRE A SEPARATE SUBMITTAL TO
 ENGINEERING SERVICES.
 3. AN OFF-SITE UTILITY/MAINTENANCE AGREEMENT WILL BE
 REQUIRED FOR PRIVATE FORCEMAIN IN RIGHT-OF-WAY.
  

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status   Date   Cont ID  
Sent By   Date 12-16-2014 Time   Rev Time 0.00
Received By bcollins Date 12-16-2014 Time 16:21 Sent To  
Notes
2014-12-16 16:25:051. TRAFFIC STUDY RECOMMENDS ADDITION OF NB LEFT TURN
 LANE FROM HAVERHILL INTO SITE. IS THIS BEING PROVIDED?
 2. IT IS RECOMMENDED THAT AN EVALUATION OF THE SITE
 ENTRANCE AT HAVERHILL BE ANALYZED. I HAVE CONCERNS
 REGARDING THE ABILITY OF LEFT TURNS FROM THE SITE TO
 ADEQUATELY AND SAFELY ENTER ONTO HAVERHILL.
 3. THE CONCURRENCY LETTER FROM PB COUNTY INDICATES
 PREVIOUS APPROVAL OF 226 UNITS - SHOULD THAT HAVE BEEN
 116?

Review Stop Z ZONING
Rev No 3 Status P Date 01-09-2015 Cont ID  
Sent By llouie Date 01-09-2015 Time   Rev Time 0.00
Received By llouie Date 01-09-2015 Time   Sent To  
Notes
2016-08-10 09:29:17RECOMMENDED FOR APPROVAL WITH THE FOLLOWING CONDITIONS:
  
 1.) THE APPLICANT SHALL ADDRESS ALL PPRC COMMENTS.
  
 2.) A RE-PLAT OF SUBJECT PROPERTY (PHASE II) AND PHASE
 I OF THE CHARLESTON COMMONS RPD IS REQUIRED. THE CITY
 SHALL APPROVE THE RE-PLAT OF THE PROPERTIES PRIOR TO
 THE SUBMISSION OF BUILDING PERMITS.
  
 3.) A WALKING PATH SHALL BE PROVIDED AROUND THE LAKE
 TRACT. THE WALKING PATH SHALL BE CONNECTED TO
 PEDESTRIAN ACCESS POINTS THAT WILL ALLOW RESIDENTS OF
 THE COMMUNITY TO HAVE ACCESS TO THE LAKE.
  
 4.) THE TWO (2) ENTRANCE MONUMENT SIGNS SHALL BE
 SETBACK 15 FEET FROM THE ROAD RIGHT-OF-WAY, PER
 ORDINANCE NO. 4077-07.
  
 5.) ALL NEW PRIVATE DEVELOPMENT, NEW CONSTRUCTION,
 RENOVATION OR REMODELING, WHERE THE TOTAL VERTICAL
 CONSTRUCTION OF ALL BUILDINGS ON A PROJECT SITE ARE
 EQUAL OR GREATER THAN $500,000.00, IS SUBJECT TO THE
 ART IN PUBLIC PLACES REQUIREMENTS OUTLINED IN CHAPTER
 78, ARTICLE V OF THE CITY'S CODE OF ORDINANCES.
  
 6.) A TREE ALTERATION PERMIT FROM THE DEVELOPMENT
 SERVICES DEPARTMENT - PLANNING DIVISION SHALL BE
 OBTAINED PRIOR TO THE REMOVAL OF ANY TREES ON THE
 PROPERTY. A PLAN FOR THE MITIGATION OF TREES SHALL BE
 REQUIRED AT THE TIME OF SUBMISSION FOR A TREE
 ALTERATION PERMIT.
  
 7.) PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF
 OCCUPANCY (CO), THE 10 FOOT BY 15 FOOT SCHOOL BUS
 SHELTER SHALL BE CONSTRUCTED BY THE DEVELOPER IN A
 LOCATION AND MANNER ACCEPTABLE TO THE PALM BEACH COUNTY
 SCHOOL BOARD. THE BUS SHELTER SHALL BE THE MAINTENANCE
 RESPONSIBILITY OF THE DEVELOPMENT.
  
 8.) THE DEVELOPER SHALL POST A NOTICE OF ANNUAL
 BOUNDARY SCHOOL ASSIGNMENTS FOR STUDENTS FROM THIS
 DEVELOPMENT IN ACCORDANCE WITH THE REQUIREMENTS OF THE
 PALM BEACH COUNTY SCHOOL BOARD.
  

Review Stop Z ZONING
Rev No 2 Status F Date 12-18-2014 Cont ID  
Sent By llouie Date 12-17-2014 Time   Rev Time 0.00
Received By llouie Date 12-17-2014 Time   Sent To  
Notes
2014-12-18 15:20:02GENERAL COMMENTS:
  
 1.) MORE INFORMATION NEEDED TO WHY WAIVERS ARE BEING
 REQUESTED - I.E. ARE THERE SITE/DESIGN CONSTRAINTS?
 WHAT ARE THE INCENTIVES FOR WAIVING THE REQUIREMENTS
 AND HOW WILL IT BENEFIT THE COMMUNITY/CITY? WHAT ARE
 THE IMPACTS AND HOW ARE THE IMPACTS BEING MITIGATED IN
 THE SITE DESIGN? HAVE OTHER ALTERNATIVES BEEN EXPLORED?
 ETC. ADDITIONAL INFORMATION IS NECESSARY IN ORDER TO
 ASSESS/SUPPORT THE WAIVER REQUESTS.
  
 2.) RE-PLAT IS REQUIRED. THE SITE PLAN WILL BE
 CONTINGENT UPON THE APPROVAL OF THE RE-PLAT.
  
 3.) PUBLIC UTILITY LETTERS REQUIRED FROM: AT&T AND
 COMCAST.
  
  
 SITE PLAN:
  
 1.) CHECK REQUIRED AND PROVIDED PARKING COUNT FOR PHASE
 I IN DATA TABULAR. CALCULATIONS ARE INCORRECT.
  
  
 LANDSCAPE PLAN:
  
 1.) PALM TREES MAY BE SUBSTITUTED FOR NOT MORE THAN 35
 PERCENT OF REQUIRED SHADE/FLOWERING TREES. WHEN PALM
 TREES ARE SUBSTITUTED FOR SHADE TREES TWO (2) PALM
 TREES SHALL BE PROVIDED FOR EACH REQUIRED SHADE TREE;
 HOWEVER, WHEN CLUSTERING OF PALM TREES IS UTILIZED, A
 MINIMUM OF THREE (3) PALM TREES PER CLUSTER SHALL BE
 REQUIRED. PLANT SCHEDULE FOR THE MODEL UNITS SHOW
 CLUSTERS OF TWO (2) PALMS ONLY. [ZLDR S.94-442(C) AND
 ZLDR S.94-445(4)(A.)]
  
  
 ARCHITECTURAL
  
 1.) IS THERE A UNIT D MODEL TYPE? PLANS SEEM TO
 INDICATE SO, BUT NO FLOOR PLANS HAVE BEEN PROVIDED FOR
 THIS MODEL.
  
  
 SIGNAGE:
  
 1.) PER ORDINANCE NO. 4077-07, THE ENTRANCE SIGNS ARE
 TO BE SETBACK 15 FT. FROM THE ENTRY ROAD RIGHT-OF-WAY,
 AND NOT 12 FT. AS NOTED IN THE PLANS.
  

Review Stop Z ZONING
Rev No 1 Status F Date 11-07-2014 Cont ID  
Sent By llouie Date 11-07-2014 Time 15:15 Rev Time 0.00
Received By llouie Date 11-07-2014 Time 15:15 Sent To  
Notes
2014-11-07 15:20:08GENERAL COMMENTS:
  
 1.) RE-PLAT IS REQUIRED. PLEASE SUBMIT A SEPARATE
 APPLICATION FOR A MAJOR SUBDIVISION. THE SUBDIVISION
 SHALL BE DESIGNED IN ACCORDANCE WITH THE REGULATIONS
 CONTAINED IN ARTICLE XI OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS.
  
 2.) PUBLIC UTILITY LETTERS REQUIRED FROM: AT&T, FP&L
 AND COMCAST.
  
 3.) CONCURRENCY LETTERS REQUIRED FROM PALM BEACH COUNTY
 TRAFFIC DIVISION AND THE SCHOOL DISTRICT OF PALM BEACH
 COUNTY.
  
 4.) THE SURVEY IS NOT ABSTRACTED NOR IS IT SIGNED AND
 SEALED BY A FLORIDA LICENSED LAND SURVEYOR. PLEASE
 ADDRESS.
  
 5.) A TREE ALTERATION PERMIT SHALL BE REQUIRED TO
 RELOCATE OR REPLACE TREES TO BE REMOVED, OR PROVIDE
 PAYMENT IN LIEU INTO THE LANDSCAPE TRUST ACCOUNT FOR
 TREES THAT CANNOT BE RELOCATED, REPLACED OR INSTALLED
 DUE TO PREEXISTING SITE DEVELOPMENT CONSTRAINTS AS
 DETERMINED BY THE PLANNING AND ZONING ADMINISTRATOR.
 [ZLDR S.94-448(D) AND (E)]
  
  
 REQUIREMENTS FOR A PLANNED DEVELOPMENT DISTRICT:
  
 1.) THE PROPOSED PD SHALL COMPLY WITH THE FOLLOWING
 CODE COMPLIANCE STANDARDS OF THE ZLDR. PLEASE PROVIDE A
 WRITTEN RESPONSE TO HOW THE PROJECT WILL MEET EACH OF
 THESE STANDARDS: [ZLDR S.94-207(B)(1)]
 - SECTION 94-35(C) - SITE DESIGN QUALITATIVE
 DEVELOPMENT STANDARDS
 - SECTION 94-33 - COMPREHENSIVE PLAN CONSISTENCY
 - ARTICLE XII - NATURAL RESOURCE PROTECTION
 - ARTICLE XVII - FLOOD PREVENTION AND CONTROL
  
 2.) UNIFIED CONTROL: IS THERE A PLAN TO UNIFY THE
 PARCELS? [ZLDR S.94-207(B)(8)]
  
 3.) SUBMIT A PROPOSED SCHEDULE OF DEVELOPMENT WHICH
 IDENTIFIES THE ANTICIPATED PROJECT START AND COMPLETION
 DATES, STAGES OF DEVELOPMENT AND THE AREA AND LOCATION
 OF COMMON OPEN SPACE TO BE PROVIDED AT EACH STAGE.
 [ZLDR S.94-207(B)(10)(C)]
  
  
 SITE PLAN:
  
 1.) ADD THE FOLLOWING INFORMATION IN THE SITE DATA
 TABULAR: TOTAL GROSS BUILDING SQUARE FOOTAGE;
 PERCENTAGE OF OPEN SPACE, LANDSCAPING, BUILDING
 COVERAGE AND IMPERMEABLE SURFACES; ACRES AND PERCENT OF
 WATER BODIES; PARKING COMPUTATIONS (PARKING
 REQUIRED/PROVIDED), AND THE MINIMUM DESIGN STANDARDS
 FOR SUCH FEATURES AS LOT SHAPE AND SIZE, BUILDING SIZE
 AND LOT COVERAGE. INCLUDE INFORMATION OF WAIVERS THAT
 HAVE BEEN APPROVED/PROPOSED.
  
 2.) PARKING FOR LESS THAN THREE (3) RESIDENTIAL
 DWELLING UNITS SHALL BE ACHIEVED BY ONE OF THE
 FOLLOWING: 1.) A SINGLE DRIVEWAY WITH A WIDTH OF NO
 GREATER THAN 20 FT. AT THE PROPERTY LINE, OR 2.) WHERE
 THE DRIVEWAY ADJOINS THE APRON IF THE APRON IS NOT
 LOCATED WHOLLY WITHIN THE RIGHT-OF-WAY. PARKING FOR THE
 PROPOSED FEE SIMPLE LOTS DO NOT COMPLY WITH THIS
 REQUIREMENT. [ZLDR S.94-313(1)(C)]
  
 3.) THE WAVE RACK PROPOSED FOR BICYCLE PARKING (DETAIL
 "H") IS NOT PERMITTED. PLEASE REFER TO THE CITY'S
 BICYCLE PARKING GUIDELINES FOR RECOMMENDED BICYCLE RACK
 ELEMENTS.
  
 4.) REVISE THE PARKING STALL PAINTING DETAIL TO
 ILLUSTRATE COMPLIANCE WITH THE DIMENSIONS ILLUSTRATED
 IN ZLDR S. 94-485(J).
  
 5.) THE BUILDING TYPICALS DO NOT CORRESPOND WITH THE
 BUILDING TYPES IN THE SITE PLAN, AND THE BUILDING
 NUMBERS IN THE TYPICAL DO NOT CORRESPOND WITH THE
 BUILDING NUMBERS IN THE SITE PLAN. PLEASE ADDRESS FOR
 CONSISTENCY.
  
 6.) THE 4 FT. HIGH DECORATIVE FENCE WITH COLUMNS IS NOT
 CONSISTENT WITH DETAIL "G". ADDRESS FOR CONSISTENCY.
  
 7.) PROVIDE A BUILDING TYPICAL FOR THE 7-UNIT BUILDING
 IN PHASE I.
  
 8.) HOW WILL GARBAGE COLLECTION SERVICES BE PROVIDED
 FOR THE UNITS IN PHASE II?
  
 9.) PLEASE ILLUSTRATE THE LOCATION OF THE A/C UNIT FOR
 EACH TOWNHOUSE UNIT IN PHASE II.
  
 10.) PROVIDE ARCHITECTURAL ELEVATIONS AND FLOOR PLANS
 FOR THE CABANA, GUARDHOUSE AND STRUCTURE FOR THE
 MAILBOXES.
  
 11.) WHAT IS THE STRUCTURE AT THE REAR OF ALL UNITS IN
 PHASE II? PLEASE IDENTIFY/LABEL THIS STRUCTURE IN THE
 PLANS.
  
 12.) WILL THERE BE AN OUTDOOR TRASH RECEPTACLE? IF SO,
 WHERE WILL IT BE LOCATED?
  
  
 LANDSCAPE PLAN:
  
 1.) PROVIDE A LANDSCAPE DATA TABULAR CLEARLY DISPLAYING
 THE RELEVANT STATISTICAL INFORMATION NECESSARY FOR THE
 EVALUATION OF COMPLIANCE WITH THE PROVISIONS OF ARTICLE
 XIV OF THE ZONING AND LAND DEVELOPMENT REGULATIONS.
 THIS INCLUDES GROSS ACREAGE OR SQUARE FOOTAGE, GROSS
 OPEN SPACE, AND SQUARE FOOTAGE OF PAVED AND LANDSCAPED
 AREAS, ETC.
  
 2.) EACH TOWNHOUSE UNIT SHALL COMPLY WITH THE FOLLOWING
 LANDSCAPING REQUIREMENTS PER SECTION 94-442(B)(2)(A) OF
 THE ZONING AND LAND DEVELOPMENT REGULATIONS:
 - ONE (1) SHADE OR FLOWERING TREE PROVIDED PER 1,200
 SQ. FT. OF OPEN SPACE.
 - ONE (1) SHRUB PER 500 SQ. FT. OF OPEN SPACE.
  
 3.) 1,000 SQ. FT. OR 75 PERCENT OF THE FRONT YARD AREA
 SHALL BE LANDSCAPED WITH LIVING PLANT MATERIAL (I.E.
 GRASS, GROUND COVER, SHRUBS, HEDGES, VINES OR TREES).
 [ZLDR S.94-482(A)]
  
 4.) THE RECREATION AREA SHALL COMPLY WITH THE FOLLOWING
 LANDSCAPING REQUIREMENTS PER ZLDR S.94-442(B)(2)(B):
 - ONE (1) SHADE TREE SHALL BE PLANTED FOR EACH 1,600
 SQ. FT. OF OPEN SPACE.
 - ONE (1) FLOWERING TREE SHALL BE PLANTED FOR EACH
 6,400 SQ. FT.
 - ONE (1) SHRUB PER 500 SQ. FT. OF OPEN SPACE.
  
 5.) PALM TREES CAN ONLY BE SUBSTITUTED FOR 35 PERCENT
 OF THE REQUIRED SHADE OR FLOWERING TREES. [ZLDR
 S.94-442(C)]
  
 6.) UNIT PLANT SCHEDULED NOT PROVIDED FOR ALL UNIT
 BUILDING TYPES. PLEASE ADDRESS.
  
 7.) CORNER CLIP AND VISIBILITY TRIANGLES IMPROPERLY
 LABELLED. PLEASE CORRECT.
  
 8.) CORRECT LANDSCAPE NOTE #4. VISIBILITY SHALL NOT BE
 OBSCURED BETWEEN 18 INCHES AND 8 FT. (NOT 30 INCHES AND
 8 FT.). [ZLDR S.94-305(E)]
  
  
 TOWNHOUSE REGULATIONS:
  
 1.) THE MINIMUM LOT AREA FOR EACH TOWNHOUSE UNIT SHALL
 BE 1,800 SQ. FT. [ZLDR S.94-309(G)(6)(A)]
  
 2.) SUBMIT SCALED ELEVATIONS OF EACH TYPE OF TOWNHOUSE
 BUILDING. THE BUILDINGS SHALL NOT EXCEED 35 FT. IN
 HEIGHT. [ZLDR S.94-309(G)(6)C)]
  
 3.) THE FLOOR AREA FOR EACH TOWNHOUSE UNIT SHALL BE A
 MINIMUM OF 900 SQ. FT. OF NET FLOOR AREA, EXCLUDING
 ATTIC, GARAGE AND UTILITY AREAS. PROVIDE ARCHITECTURAL
 FLOOR PLANS AND CALCULATIONS ILLUSTRATING THAT THIS
 REQUIREMENT HAS BEEN MET. [ZLDR S.94-309(G)(6)(F)]
  
  
 ARCHITECTURAL:
  
 1.) PROVIDE SCALED FLOOR PLANS, ELEVATIONS,
 PERSPECTIVES, ETC. OF ALL PROPOSED STRUCTURE TYPES AND
 IMPROVEMENTS. [ZLDR S.94-207(B)(10)(F)]
  
  
 SIGNAGE:
  
 1.) PROVIDE SETBACK DIMENSIONS FROM THE PROPERTY LINE.
  
  
 LIGHTING:
  
 1.) ARE STREET LIGHTS PROPOSED FOR PHASE II? IF SO,
 PLEASE ILLUSTRATE THE LOCATION OF THE LIGHT FIXTURES
 AND PROVIDE A PHOTOMETRIC PLAN SHOWING THE LEVEL OF
 INTENSITY AT THE PROPERTY LINES FOR ALL OUTDOOR
 ILLUMINATION.
  
  
 SUGGESTED IMPROVEMENTS:
  
 1.) CONSIDER ADDING A WALKING PATH AROUND THE LAKE.
  
 2.) CROSSWALKS THROUGHOUT THE DEVELOPMENT AND
 CONNECTING TO RECREATION AREAS ARE DESIRED.
  
 3.) CONSIDER ADDING A SECONDARY ACCESS POINT INTO THE
 PROPOSED DEVELOPMENT.
  
  
  
 NOTES:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF
 FIFTEEN (15) PAPER COPIES, ONE (1) REDUCED COPY IN 8
 1/2 INCHES X 11 INCHES AND ONE (1) SET IN 11 INCHES X
 17 INCHES, AND AN ELECTRONIC COPY OF ALL PLANS. PLEASE
 NOTE THAT CHANGES ON THE RESUBMITTED PLANS MAY RESULT
 IN ADDITIONAL COMMENTS.
  
 * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE.
  
 * ANY CHANGES ON THE RESUBMITTED PLANS MAY RESULT IN
 ADDITIONAL COMMENTS.
  

  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved