Plan Review Details - Project Z14090016
Plan Review Stops For Project Z14090016
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 10-07-2014 Cont ID  
Sent By llouie Date 10-07-2014 Time 19:16 Rev Time 0.00
Received By rbrown Date 10-07-2014 Time 19:16 Sent To  
Notes
2014-10-07 19:28:02DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR PERMITTING.
  
 2. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL
 SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS
 WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND
 OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA
 BUILDING CODE
  
 3. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH
 ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND
 OPENING PROTECTIVE REQUIREMENTS OF SECTION R302 OF
 FLORIDA BUILDING CODE (RESIDENTIAL) SHALL BE VERIFIED.
  
 4. ALL APPLICABLE PERMITS AND SUB-PERMITS MUST BE
 OBTAINED BEFORE COMMENCING THE WORK. SEPARATE PERMITS,
 PLANS AND FEES, ARE REQUIRED FOR SWIMMING POOLS AND
 SPAS, GAS SYSTEMS, GENERATORS, FIRE ALARM SYSTEMS, FIRE
 SPRINKLER AND OTHER FIRE SUPPRESSION SYSTEMS, GREASE
 INTERCEPTORS, SITE LIGHTING, SITE LANDSCAPE, SITE
 IRRIGATION, ETC.
  
 5. FOR STREET ADDRESSING CONTACT SCOTT ALEF, GIS
 SUPPORT SPECIALIST, AT (561) 494 1094, OR BY EMAIL:
 [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status P Date 09-30-2014 Cont ID  
Sent By cranford Date 09-30-2014 Time 12:43 Rev Time 0.00
Received By cranford Date 09-30-2014 Time 12:41 Sent To  
Notes
2014-09-30 12:43:25ENGINEERING/PUBLIC WORKS DEPT.
 LAND DEVELOPMENT AND STORMWATER
  
 1. POTABLE WATER, SANITARY SEWER, SOLID WASTE, AND
 STORMWATER SERVICE TO BE PROVIDED BY PALM BEACH COUNTY.
 UTILITY DESIGN AND WORK WITHIN RIGHT-OF-WAY MUST MEET
 COUNTY STANDARDS.
  
 2. INDICATE THE LOCATIONS OF THE DUMPSTERS INTENDED TO
 BE SERVICE BY THE SOLID WASTE AUTHORITY OF PALM BEACH
 COUNTY. DUMPSTERS MUST BE EASILY ACCESSIBLE BY THE SWA
 EQUIPMENT AND MANPOWER. INCLUDE AN ESTIMATE OF THE
 SOLID WASTE YARDAGE ANTICIPATED TO BE GENERATED BY THE
 FACILITY AND VERIFY THAT THE PROPOSED DUMPSTER
 ENCLOSURES WILL ACCOMODATE THE REQUIRED DUMPSTER SIZE.
 THE DUMPSTER ENCLOSURE SHOULD MEET THE CITY OF WEST
 PALM BEACH GARBAGE RECEPTACLE DETAIL. [CODE OF
 ORDINANCES, SECTION 94-444(B), FIGURE XIV-3]
  
 3. THE AVAILABLE WATER PRESSURE WITHIN THIS PORTION OF
 THE CITY MAY NOT BE ACCEPTABLE AT ELEVATIONS HIGHER
 THAN THE 2ND FLOOR. WE RECOMMEND THAT A LONG-TERM
 PRESSURE STUDY BE PERFORMED ON THE COUNTY'S POTABLE
 WATER LINES PRIOR TO FINALIZATION OF THE DESIGN.
  
 4. REVISE THE PLANS TO INDICATE WHICH PORTIONS OF THE
 POTABLE WATER, SANITARY SEWER, AND STORMWATER SYSTEM
 WILL REMAIN PUBLICALLY OWNED AND WHICH SECTIONS WILL BE
 MAINTAINED BY THE APPLICANT.
  
 5. PLEASE SHOW THE LOCATIONS OF THE ROOF DRAINS AND
 INDICATE WHERE THE RUNOFF FROM THE ROOF DRAINS WILL BE
 DIRECTED. THE ROOF DRAIN PEAK DISCHARGE RATE AND
 VELOCITY WILL NEED TO BE INCLUDED IN THE FINAL DESIGN
 OF THE STORMWATER MANAGEMENT SYSTEM.
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 ENGINEERING & PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
 [email protected]
 561-494-1098 (OFFICE)
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 10-06-2014 Cont ID  
Sent By pleduc Date 10-06-2014 Time   Rev Time 0.00
Received By pleduc Date 10-06-2014 Time 14:12 Sent To  
Notes
2014-10-06 14:44:08THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION, WEST PALM
 BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESSES SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. TRASH AND DEBRIS IS TO BE REMOVED FROM THE SITE
 DAILY OR MORE OFTEN TO REDUCE THE ACCUMULATION OF
 POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. ALL APARTMENT BUILDINGS SHALL COMPLY WITH THE
 FLORIDA FIRE PREVENTION CODE, 2010 EDITION, THE LIFE
 SAFETY CODE, 2009 EDITION, INCLUDING MORE SPECIFICALLY,
 CHAPTER 30, NEW APARTMENTS. THE DESIGNATION OF A
 TOWNHOME NOT REQUIRING THE ABOVE SHALL BE REVIEWED
 THROUGH FURTHER BUILDING DESIGN AND TENANT SEPARATIONS.
  
 6. THE CLUBHOUSE AND OTHER COMMON AREAS SHALL BE
 SUBJECT TO ANNUAL FIRE INSPECTIONS.
  
 7. AT THE CULBHOUSE, BASED ON ROOF DESIGN, NOTICE IS
 REQUIRED FOR STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE
 CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR ANY
 MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE
 WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED
 WITH AN APPROVED SYMBOL. THE APPROVED SYMBOL SHALL BE
 PLACED WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY
 DOOR.
  
 8. ALL UNDERGROUND FIRE LINE INSTALLATIONS TO FIRE
 HYDRANTS AND/OR FIRE SPRINKLER SYSTEMS SHALL BE
 SUBMITTED FOR PERMIT AND INSPECTED BY THE FIRE
 PREVENTION BUREAU'S FIRE INSPECTORS.
  
 9. FIRE HYDRANT LOCATIONS SHALL BE APPROVED IN PART
 THROUGH THE FIRE PREVENTION BUREAU AT A MINIMUM OF 300'
 SEPARATION.
  
 10. GATE ACCESS POINTS SHALL BE EQUIPPED WITH A KNOX
 KEY SWITCH FOR 24HR EMERGENCY ACCESS. THE GATE SHALL
 OPEN WITH A MINIMUM FIRE LANE WIDTH OF 20'.
  
  
  
  
  

Review Stop L LANDSCAPING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 2 Status P Date 12-16-2014 Cont ID  
Sent By tward Date 12-16-2014 Time 07:22 Rev Time 0.00
Received By tward Date   Time   Sent To  
Notes
2014-12-16 07:28:041. APPLICANT'S ENGINEER'S RESPONSE LETTER TO COMMENTS
 INDICATES COMMENTS ARE BEING ADDRESSED OR WILL BE
 ADDRESSED DURING ENGINEERING PERMIT APPLICATION
 PROCESS.
  
 2. RECOMMEND WITHHOLDING C.O.'S UNTIL POA AND DRAINAGE
 EASEMENTS ARE ESTABLISHED AND DOCUMENTATION PROVIDED TO
 THE CITY.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 PUBLIC WORKS DEPARTMENT
 561-494-1120

Review Stop STORM STORMWATER
Rev No 1 Status F Date 12-08-2014 Cont ID  
Sent By tward Date 12-08-2014 Time 07:46 Rev Time  
Received By tward Date   Time   Sent To  
Notes
2014-12-08 08:17:271. PROJECT IS WITHIN THE NORTHERN PALM BEACH COUNTY
 IMPROVEMENT DISTRICT. DRAINAGE PERMIT TO BE OBTAINED
 FROM NPBCID PRIOR TO START OF CONSTRUCTION.
  
 2. THE PRELIMINARY ENGINEERING PLAN, SHEET C-1, SHOWS
 DRAINAGE PIPES UNDER BUILDINGS 1 AND 2. THE FINAL SITE
 PLAN, SHEETS PHM-1 AND PHM-2, SHOW THE DRAINAGE PIPES
 ON THE LOT LINES. PLANS NEED TO BE COORDINATED.
  
 3. WILL DRAINAGE EASEMENTS BE OBTAINED OVER THE
 PORTIONS OF THE DRAINAGE SYSTEM LOCATED OUTSIDE THE
 COMMON AREAS?
  
 4. IDENTIFY WHO WILL BE RESPONSIBLE FOR OPERATION AND
 MAINTENANCE OF THE SURFACE WATER MANAGEMENT/DRAINAGE
 SYSTEM.
  
 5. FEMA IS UPDATING THE FLOOD INSURANCE RATE MAPS
 (FIRM) FOR PALM BEACH COUNTY. THE PRELIMINARY FEMA
 FLOOD ZONES MAPS CAN BE VIEWED ON THE CITY'S GIS
 WEBSITE: HTTP://GIS.WPB.ORG/MAPSANDAPPS/
  
 6. NO GRADING PLAN PROVIDED IN THE SUBMITTAL.
  
 7. PRIOR TO STARTING CONSTRUCITON, PROVIDE A COPY OF
 THE SOUTH FLORIDA WATER MANAGEMENT DISTRICT
 ENVIRONMENTAL RESOURCES PERMIT.
  
 8. PRIOR TO START OF CONSTRUCTION, PROVIDE A COPY OF
 THE NPDES PERMIT.
  
 9. LAND USE (PERVIOUS/IMPERVIOUS) TABLE, STORMWATER
 MANAGEMENT CALCULATIONS, EROSION CONTROL PLAN (SWPPP)
 AND PAVING, GRADING AND DRAINAGE PLANS TO BE PROVIDED
 WITH THE ENGINEERING PERMIT APPLICATION.
  
 10. LABEL THE DRY RETENTION AREAS AS DRY DETENTION
 AREAS.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 PUBLIC WORKS DEPARTMENT
 (561) 494-1120
  
  

Review Stop SURVEY SURVEYING
Rev No 2 Status P Date 12-02-2014 Cont ID  
Sent By vnoel Date 12-02-2014 Time 09:39 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2014-12-02 09:40:41PASSED WITH CONDITION OF REPLAT AND FDOT APPROVAL.

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 10-06-2014 Cont ID  
Sent By vnoel Date 10-06-2014 Time 08:26 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2014-10-06 08:37:521. REPLAT WILL BE REQUIRED. SEPARATE SUBMITTAL FOR
 TECHNICAL REVIEW IS MADE THROUGH ENGINEERING SERVICES.
 2. PROPERTY IS WITHIN THE PALM BEACH COUNTY SERVICE
 AREA. APPROVAL OF SAME WILL BE REQUIRED.
 3. CONNECTIONS TO MILITARY TRAIL WILL REQUIRE FDOT
 PERMIT.
 4. GARBAGE COLLECTION MAY BE THROUGH THE CITY.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 2 Status P Date 11-18-2014 Cont ID  
Sent By   Date 11-18-2014 Time   Rev Time 0.00
Received By bcollins Date 11-18-2014 Time 08:46 Sent To  
Notes
2014-11-18 08:46:22ADD STOP SIGN, STOP BAR AND MINIMUM OF 30 FT. CENTER
 LINE STRIPING AT EXIT ONTO MILITARY TRAIL.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 10-07-2014 Time   Rev Time 0.00
Received By bcollins Date 10-07-2014 Time 08:17 Sent To  
Notes
2014-10-07 08:18:13SIGN PLAN SHOWS NO ON-SITE TRAFFIC CONTROLS. ADD STOP
 BARS AND STOP SIGNS. FDOT APPROVAL NEEDED FOR ENTRANCE.

Review Stop Z ZONING
Rev No 3 Status P Date 02-05-2015 Cont ID  
Sent By llouie Date 01-06-2015 Time   Rev Time 0.00
Received By llouie Date 12-16-2014 Time   Sent To  
Notes
2015-02-05 08:58:13** APPROVED WITH CONDITIONS **
  
 APPROVAL IS SUBJECT TO THE FOLLOWING CONDITIONS:
  
 1.) A RE-PLAT OF THE PROPERTY IS REQUIRED. CITY
 APPROVAL SHALL BE GRANTED FOR THE RE-PLAT OF THE
 PROPERTY PRIOR TO THE SUBMISSION OF BUILDING PERMITS.
  
 2.) PROVIDE A STOP BAR AND MINIMUM THIRTY (30) FEET
 CENTER LINE STRIPING AT THE EXIST ON TO MILITARY TRAIL.
  
 3.) PRIOR TO THE REMOVAL OF ANY TREES ON THE PROPERTY,
 THE APPLICANT SHALL APPLY FOR AND OBTAIN A TREE
 ALTERATION PERMIT FROM THE DEVELOPMENT SERVICES
 DEPARTMENT - PLANNING DIVISION.

Review Stop Z ZONING
Rev No 2 Status F Date 12-04-2014 Cont ID  
Sent By llouie Date 12-04-2014 Time   Rev Time 0.00
Received By llouie Date 11-17-2014 Time   Sent To  
Notes
2014-12-04 14:48:58GENERAL COMMENTS:
  
 1.) PROVIDE A LETTER FROM COMCAST CABLE COMMUNICATIONS
 CONFIRMING THAT THE PROPOSED PROJECT DOES NOT ENCROACH
 INTO THEIR EASEMENT OR OTHERWISE INTERFERE WITH THE
 PROVISIONS OF THEIR SERVICES.
  
 2.) RE-PLAT OF THE PROPERTY IS REQUIRED.
  
 3.) PRIOR TO THE REMOVAL OF ANY TREES ON THE PROPERTY,
 THE APPLICANT SHALL APPLY FOR AND OBTAIN A TREE
 ALTERATION PERMIT FROM THE DEVELOPMENT SERVICES
 DEPARTMENT - PLANNING DIVISION. THERE SEEMS TO BE TREES
 EXISTING ON THE PROPERTY.
  
  
  
 SITE PLAN:
  
 1.) 10/7/14 REPEAT COMMENT: PLEASE MAKE THE FOLLOWING
 CORRECTIONS TO THE SITE DATA TABULAR:
 - TOTAL PARKING SPACES REQUIRED FOR THE PROJECT IS 105
 (NOT 108).
 - ADDRESS THE NOTE FOR 2-CAR DRIVEWAY PARKING (MINIMUM
 WIDTH OF 17 FT. REQUIRED FOR 2-CAR DRIVEWAY PARKING; 16
 FT. WIDE DRIVEWAYS PROVIDED)
  
 2.) IT IS UNCERTAIN TO WHY THE BICYCLE PARKING WAS
 REMOVED FROM THE PLANS. PURSUANT TO ZLDR S. 94-485(Q),
 ONE (1) BICYCLE PARKING SHALL BE PROVIDED FOR EVERY
 TWENTY (20) PARKING SPACES. PLEASE RESTORE THE BICYCLE
 PARKING, AND INCLUDE ALL CALCULATIONS AND CORRECT RACK
 DETAIL IN THE PLANS.
  
 3.) A TWO-CAR DRIVEWAY SHALL HAVE A MINIMUM WIDTH OF 17
 FT. THE REVISED PLAN SHOWS THE DRIVEWAY WIDTH MEASURED
 AT 16 FT. WIDE, WHICH IS INSUFFICIENT TO ACCOMMODATE
 TWO CARS.
  
 4.) THE LOCATION OF THE FIRE HYDRANTS IN THE SITE PLAN
 AND LANDSCAPE PLAN DO NOT MATCH. PLEASE ADDRESS FOR
 CONSISTENCY AND ENSURE THERE IS NO CONFLICT IN THE
 PLANS (I.E. THERE SEEMS TO BE A FIRE HYDRANT LOCATED ON
 A FEE SIMPLE LOT IN THE MIDDLE OF AN ENTRANCE WALKWAY,
 LANDSCAPING, ETC.)
  
 5.) PARKING STALL STRIPING DETAIL ON SHEET RP-1 SHALL
 BE CONSISENT WITH THE DETAIL PROVIDED IN SECTION
 94-485(J), STALL PAINTING DETAIL. PLEASE CORRECT.
  
  
  
 LANDSCAPE PLAN:
  
 1.) A LANDSCAPE SCREEN SHALL BE PROVIDED AROUND THE
 LIFT STATION.
  
  
  
 FLOOR PLANS AND ELEVATIONS:
  
 1.) 10/17/14 REPEAT COMMENT: THE SITE PLAN SHOWS ALL
 UNITS WILL HAVE A PATIO. PLEASE ADDRESS IN THE
 ARCHITECTURAL PLANS FOR CONSISTENCY.
  
 2.) THERE IS A NOTE ON SHEET A-2 OF EACH BUILDING TYPE
 REFERENCING SHEET A-3; HOWEVER, SHEET A-3 SEEMS TO BE
 MISSING FROM THE SET. PLEASE CLARIFY.
  
 3.) LOT NUMBERS HAVE BEEN IDENTIFIED IN THE LATEST
 REVISED FLOOR PLANS. ARE THE LOT NUMBERS SUPPOSED TO
 MATCH THE LOTS IN THE SITE PLAN? PLEASE ADDRESS FOR
 CONSISTENCY.
  
 4.) THE BUILDING NUMBERS IN THE ARCHITECTURAL PLANS
 DOES NOT CORRESPOND WITH THE BUILDING NUMBERS IN THE
 SITE PLAN. ADDRESS FOR CONSISTENCY.
  
  
  
 ENTRANCE MONUMENT SIGN:
  
 1.) REPEAT COMMENT 10/7/14: INCLUDE ALL DIMENSIONS IN
 THE TYPICAL ENTRANCE SIGN DETAIL. THE FREESTANDING SIGN
 CANNOT EXCEED 48 SQUARE FEET. MEASUREMENTS FROM THE
 SITE PLAN INDICATE THE MAXIMUM ALLOWABLE SIGN AREA HAS
 BEEN EXCEEDED. PROVIDE THE DIMENSION FOR THE WIDTH OF
 THE SIGN. [ZLDR S. 94-407(2)(B.)(2.)]
  
 2.) ALL PARTS OF THE SIGN, INCLUDING THE DECORATIVE
 STRUCTURAL ELEMENTS, SHALL BE INCLUDED IN THE
 COMPUTATION OF THE SIGN AREA. [ZLDR S. 94-405(A) AND
 (B)]
  
  
  
 NOTES:
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF TEN
 (10) COPIES, ONE (1) REDUCED COPY (8 1/2 BY 11), AND AN
 ELECTRONIC COPY IN .PNG FORMAT OF ALL PLANS. PLEASE
 NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO ADDITIONAL
 COMMENTS.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% ($200) OF THE ORIGINAL APPLICATION FEE.
  

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 10-07-2014 Time   Rev Time 0.00
Received By llouie Date 10-07-2014 Time 16:26 Sent To  
Notes
2014-10-07 16:35:37GENERAL COMMENTS:
  
 1.) IT SHALL BE UNLAWFUL FOR ANY OWNER, AGENT OR PERSON
 HAVING CONTROL OF ANY LAND WITHIN THE CITY TO SUBDIVIDE
 OR LAY OUT SUCH LAND INTO MORE THAN FOUR (4) LOTS,
 UNLESS BY PLAT, AND DESIGNED IN ACCORDANCE WITH THE
 REGULATIONS CONTAINED IN ARTICLE XI OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS [SECTION 94-44(C)].
 SEPARATE SUBMITTAL AND REVIEW PROCESS REQUIRED. PLEASE
 CONTACT ENGINEERING SERVICES.
  
 2.) 100 PERCENT OF THE GROUND FLOOR BUILDING AREA OF
 EACH UNIT SHALL BE CONVEYED TO THE OWNER IN A FEE
 SIMPLE TITLE. [SECTION 94-309(G)(3)]
  
 3.) A PROPERTY OWNERS ASSOCIATION SHALL BE ESTABLISHED
 FOR THE MAINTENANCE OF ALL COMMON AREAS. [SECTION
 94-309(G)(3)]
  
 4.) CONCURRENCY LETTERS FROM PALM BEACH COUNTY TRAFFIC
 DIVISION AND THE SCHOOL DISTRICT OF PALM BEACH COUNTY
 REQUIRED.
  
 5.) PROVIDE WRITTEN CONFIRMATION FROM THE PUBLIC
 UTILITIES DEPARTMENT INDICATING THAT THERE IS
 SUFFICIENT WATER, SEWAGE TREATMENT, STORM DRAINAGE AND
 GARBAGE COLLECTION SERVICES TO SERVE THE SITE.
  
 6.) PROVIDE LETTERS FROM THE FOLLOWING PUBLIC UTILITIES
 CONFIRMING THAT THE PROPOSED PROJECT DOES NOT ENCROACH
 INTO THEIR EASEMENTS OR OTHERWISE INTERFERE WITH THE
 PROVISIONS OF THEIR SERVICES: AT&T, FLORIDA PUBLIC
 UTILITIES (FPU), FLORIDA POWER AND LIGHT (FP&L) AND
 COMCAST CABLE COMMUNICATIONS.
  
 7.) PRIOR TO THE REMOVAL OF ANY TREES ON THE PROPERTY,
 THE APPLICANT SHALL APPLY FOR AND OBTAIN A TREE
 ALTERATION PERMIT FROM THE DEVELOPMENT SERVICES
 DEPARTMENT - PLANNING DIVISION.
  
 8.) THE PARCEL SOUTH OF THE PROJECT (OXBRIDGE ACADEMY)
 IS ZONED CS AND NOT RPD. PLEASE CORRECT IN PLANS.
  
 9.) PROVIDE A PLAN SHOWING THE LOCATION, HEIGHT AND
 INTENSITY OF ALL OUTDOOR ILLUMINATION.
  
 10.) PROPOSED 10 FT. UTILITY EASEMENT DOES NOT SEEM
 CONNECTED. PLEASE CLARIFY.
  
 11.) FDOT APPROVAL REQUIRED FOR CONNECTION ON MILITARY
 TRAIL.
  
  
 SITE PLAN:
  
 1.) THE SITE PLAN SHALL COMPLY WITH THE GENERAL DESIGN
 STANDARDS FOR SUBDIVISION DESIGN PURSUANT TO SECTION
 94-342 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS.
  
 2.) MORE INFORMATION IS NEEDED IN THE SITE DATA TABULAR
 REGARDING THE PERCENTAGES PROVIDED FOR REQUIRED AND
 PROPOSED IMPERVIOUS SPACE, OPEN SPACE, LANDSCAPED SPACE
 AND BUILDING COVERAGE AND FAR. THE FIGURES DO NOT ADD
 UP. SQUARE FOOTAGE CALCULATIONS AND THE BREAKDOWN OF
 OPEN SPACE SHOULD BE INCLUDED IN THE DATA TABULAR.
  
 3.) PLEASE MAKE THE FOLLOWING CORRECTIONS IN THE SITE
 DATA TABULAR:
  A.) 2 PARKING SPACES REQUIRED FOR EACH UNIT (NOT
 BEDROOM)
 B.) TOTAL PARKING SPACES REQUIRED FOR THE PROJECT IS
 105 (NOT 103)
  C.) INCLUDE THE CALCULATIONS FOR GUEST PARKING (1
 PARKING SPACE FOR EVERY 10 UNITS)
  
 4.) REVISE NOTE FOR THE PERPETUAL EASEMENT TO INCLUDE
 ITS PURPOSE.
  
 5.) PROVIDE CLARIFICATION ON THE DRIVEWAY ACCESS TO THE
 UNITS. THE CENTER BLOCK CONTAINING BUILDINGS #5, #6, #7
 AND #8 SEEM TO BE CURBED. HOW TO VEHICLES GET ACCESS TO
 DRIVEWAYS?
  
 6.) WILL THERE BE A GATE AT THE EMERGENCY ACCESS PATH?
 IF SO, PLEASE DELINEATE IN THE PLAN.
  
 7.) REVISE THE TOWNHOUSE PROPERTY DEVELOPMENT STANDARDS
 TO REFLECT A MAXIMUM HEIGHT OF 35 FEET.
  
 8.) DELETE THE 6 FT. BY 9 FT. BICYCLE RACK DETAIL IN
 SHEET RP.1. THIS RACK WILL NOT BE UTILIZED IN THE
 PROJECT.
  
 9.) WHAT IS THE HEIGHT OF THE PERIMETER POOL FENCE? THE
 HEIGHT OF THE POOL BARRIER MUST COMPLY WITH THE MINIMUM
 STANDARDS SET FORTH IN SECTION 94-304(D)(2)(B.) OF THE
 ZLDR.
  
 10.) A 6 FT. HIGH BLACK CHAIN LINK FENCE IS DEPICTED
 WITHIN THE EASTERN PERIMETER BUFFER. PLEASE REVISE
 DETAIL E (10' ROW BUFFER WITH 5' U.E. OVERLAP) TO
 DELINEATE THE FENCE. THE FENCE, TREES AND SHRUBS CANNOT
 BE PLANTED WITHIN THE GENERAL UTILITY EASEMENT.
  
 11.) DIRECTIONAL TRAFFIC ARROWS ARE RECOMMENDED AT THE
 ENTRANCE GATE.
  
 12.) ADDITIONAL PEDESTRIAN FEATURES (I.E. CROSSWALKS
 AND SIDEWALKS, ACCESS POINTS IN/OUT OF DEVELOPMENT) ARE
 DESIRABLE.
  
 13.) WHERE WILL DUMPSTERS BE LOCATED? PUBLIC WORKS
 DEPARTMENT TO REVIEW ROADWAY CIRCULATION DESIGN FOR
 SERVICE AND VEHICLE ACCESSIBILITY.
  
  
 LANDSCAPE PLAN:
  
 1.) LANDSCAPE COMPLIANCE TABULAR REQUIRES CLARIFICATION
 IN ORDER TO DETERMINE COMPLIANCE WITH ARTICLE XIV OF
 THE ZONING AND LAND DEVELOPMENT REGULATIONS. PLEASE
 REVISE CALCULATIONS TO CLEARLY DISPLAY ALL RELEVANT
 INFORMATION, INCLUDING, BUT NOT LIMITED TO THE
 FOLLOWING: GROSS ACREAGE/SQUARE FOOTAGE, GROSS OPEN
 SPACE, SQUARE FOOTAGE OF PAVED LAND AND LANDSCAPED
 AREAS, EXISTING AND PROPOSED USE, ZONING DISTRICT, OPEN
 SPACE FOR TOWNHOUSE LOTS AND RECREATION AREA.
  
 2.) PAVEMENT AND WALKWAYS IS TO COUNT TOWARDS OPEN
 SPACE REQUIREMENTS. REVISE DATA TABLES AND ALL
 CALCULATIONS.
  
 3.) EACH TOWNHOUSE UNIT SHALL COMPLY WITH THE FOLLOWING
 LANDSCAPING REQUIREMENTS PER SECTION 94-442(B)(2)(A.)
 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS.
 A.) ONE (1) SHADE OR FLOWERING TREE REQUIRED PER 1,200
 SQ. FT. OF OPEN SPACE.
 B.) ONE (1) SHRUB PER 500 SQ. FT. OF OPEN SPACE.
  
 4.) TREES AND SHRUBS CANNOT BE PLANTED WITHIN THE
 GENERAL UTILITY EASEMENTS.
  
 5.) TREES AND HEDGES CANNOT BE PLANTED OR MAINTAINED
 WITHIN 3 FEET OF A FIRE HYDRANT. [ZLDR S.94-302(A)(1)]
  
 6.) CONSIDERATION MUST BE GIVEN THE LANDSCAPE PLAN AND
 WHETHER OR NOT RESIDENTS WILL HAVE THE ABILITY
 CONSTRUCT SCREEN ENCLOSURES, PRIVACY WALLS OR FENCES
 ALONG PROPERTY LINES. THIS MAY IMPACT THE DESIGN OF THE
 LANDSCAPE PLAN.
  
 7.) SUBMIT A PLAN FOR STREET TREES. CONSIDER MOVING
 WATER METERS CLOSER TO THE CURB TO ALLOW FOR THE
 PLANTING OF STREET TREES.
  
 8.) OAK TREES SHALL BE PROVIDED WITH A ROOT BARRIER TO
 PREVENT DAMAGE TO BUILDINGS AND PAVEMENT. IT IS
 RECOMMENDED THAT THE PROPOSED OAK TREES AT THE REAR
 YARDS OF LOTS ARE MOVED FURTHER AWAY FROM THE
 STRUCTURE.
  
 9.) RECREATION AREA: EACH ROW OF PARKING SPACES SHALL
 BE TERMINATED BY LANDSCAPE ISLANDS NOT LESS THAN 5 FEET
 IN WIDTH AND NOT LESS THAN THE ADJACENT PARKING STALL.
 THE LANDSCAPE ISLAND SHALL HAVE A MINIMUM OF 2 ? FEET
 AT ITS END SO AS TO ALLOW FOR CAR MANEUVERING. THE
 LANDSCAPE ISLAND SHALL CONTAIN AT LEAST 1 SHADE OR
 FLOWERING TREE. [ZLDR S. 94-443(C)(3)(A.)]
  
 10.) SEE ADDITIONAL LANDSCAPING REQUIREMENTS FOR
 MULTIFAMILY RESIDENTIAL USES [SECTION 94-443(D)]. IT
 APPEARS ALL REQUIREMENTS HAVE BEEN MET, BUT PLEASE
 INCLUDE THEM IN THE LANDSCAPE CALCULATIONS TABLE.
  
 11.) NOTATE THE LOCATION OF UTILITY EASEMENTS AND
 BUFFERS IN THE LANDSCAPE PLAN.
  
 12.) RECREATION POD LANDSCAPE REQUIREMENTS [SECTION
 94-442(B)(2)(B.)]: ONE (1) SHADE TREE PER 1,600 SQ. FT.
 OF OPEN SPACE; ONE (1) FLOWERING TREE PER 6400 SQ. FT.
 OF OPEN SPACE; AND ONE (1) SHRUB PER 500 SQ. FT. OF
 OPEN SPACE. PLEASE ILLUSTRATE COMPLIANCE.
  
  
 FLOOR PLANS AND ELEVATIONS:
  
 1.) UNITS MUST BE A MINIMUM OF 900 SQ. FT. OF NET FLOOR
 AREA, EXCLUDING ATTIC, GARAGE AND UTILITY AREAS. IT
 APPEARS THAT THIS REQUIREMENT HAS BEEN MET, BUT PLEASE
 INCLUDE THE CALCULATIONS. [SECTION 94-309(G)(6)(F.)]
  
 2.) FLOOR PLANS AND ELEVATIONS FOR BUILDING TYPE AVANTI
 (DL AND DR) DO NOT MATCH. PLEASE ADDRESS.
  
 3.) THE SITE PLAN SHOWS ALL UNITS WILL HAVE A PATIO.
 PLEASE ADDRESS IN THE ARCHITECTURAL PLANS FOR
 CONSISTENCY.
  
 4.) IT IS RECOMMENDED THAT THE UNITS FACING THE STREET
 WITH A SIDE ENTRANCE ARE IMPROVED WITH ARCHITECTURAL
 FEATURES (I.E. SHUTTERS, ORNAMENTS, ETC.) TO PROVIDE
 FOR ENHANCED FRONTAGES ALONG STREETS.
  
 5.) ADDRESS THE OVERLAPPING TEXT IN THE PLANS.
  
  
 ENTRANCE MONUMENT SIGN:
  
 1.) INCLUDE ALL DIMENSIONS IN THE TYPICAL ENTRANCE SIGN
 DETAIL. THE FREESTANDING SIGN CANNOT EXCEED 48 SQUARE
 FEET. MEASUREMENTS FROM THE SITE PLAN INDICATE THE
 MAXIMUM ALLOWABLE SIGN AREA HAS BEEN EXCEEDED. [ZLDR S.
 94-407(2)(B.)(2.)]
  
 2.) THE SIGN SHALL BE SETBACK 20 FEET FROM THE PUBLIC
 RIGHT-OF-WAY IF NOT PLACED PARALLEL TO THE STREET.
 [ZLDR S.94-407(2)(E.)]
  
  
 INSTRUCTIONS FOR RESUBMITTAL:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF TEN
 (10) COPIES, ONE (1) REDUCED COPY (8 ? BY 11), AND AN
 ELECTRONIC COPY IN .PNG FORMAT OF ALL PLANS. PLEASE
 NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO ADDITIONAL
 COMMENTS.
  
 * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% ($200) OF THE ORIGINAL APPLICATION FEE.
  