Plan Review Details - Project Z14080019
Plan Review Stops For Project Z14080019
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 09-10-2014 Cont ID  
Sent By cranford Date 09-03-2014 Time 10:56 Rev Time 0.00
Received By rbrown Date 09-10-2014 Time 12:01 Sent To  
Notes
2014-09-10 12:10:29DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR PERMITTING.
  
 2. THE PROPOSED BUILDING WILL BE IN FLOOD ZONE AE. THE
 ELEVATION OF THE FIRST FLOOR OF THE BUILDING AND ALL
 ASSOCIATED MECHANICAL EQUIPMENT (CHILLERS, GENERATORS
 ETC.) SHALL BE 6 INCHES (FREEBOARD) ABOVE THE BASE
 FLOOD ELEVATION.
  
 3. ANY PART OF AN ACCESSIBLE ROUTE WITH A SLOPE GREATER
 THAN 1:20 SHALL BE CONSIDERED A RAMP AND SHALL COMPLY
 WITH SECTION 405 OF FLORIDA ACCESSIBILITY CODE.
  
 4. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL
 SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS
 WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND
 OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA
 BUILDING CODE
  
 5. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH
 ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND
 OPENING PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 OF
 THE FLORIDA BUILDING CODE SHALL BE VERIFIED.
  
 6. ALL APPLICABLE PERMITS AND SUB-PERMITS MUST BE
 OBTAINED BEFORE COMMENCING THE WORK.94, OR BY EMAIL:
 [email protected]
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 2 Status F Date 12-31-2014 Cont ID  
Sent By cranford Date 12-31-2014 Time 14:55 Rev Time 0.00
Received By cranford Date 12-31-2014 Time 14:49 Sent To  
Notes
2014-12-31 14:55:44ENGINEERING/PUBLIC WORKS DEPT.
 LAND DEVELOPMENT AND STORMWATER
 3RD REVIEW
  
 THE PROPOSED BUILDING IS NOT WITHIN THE CITY OF WEST
 PALM BEACH POTABLE WATER SERVICE AREA. IF THE BUILDING
 IS NOT PROPOSED TO BE SERVED BY RIVIERA BEACH
 UTILITIES, PROVIDE A WRITTEN REQUEST FROM RIVIERA BEACH
 REQUESTING THAT SERVICE BE PROVIDED BY THE CITY OF WEST
 PALM BEACH.
  
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 ENGINEERING & PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
 [email protected]
 561-494-1098 (OFFICE)

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 09-03-2014 Cont ID  
Sent By cranford Date 09-03-2014 Time 10:57 Rev Time 0.00
Received By cranford Date 09-03-2014 Time 10:57 Sent To  
Notes
2014-09-03 08:45:43ENGINEERING/PUBLIC WORKS DEPT.
 LAND DEVELOPMENT / STORMWATER
  
 THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION
 DETAILLS WILL BE REVIEWED AS PART OF THE ENGINEERING
 DEVELOPMENT APPROVAL AND BUILDING PERMIT APPLICATION
 PROCESSES.A RIGHT-OF-WAY PERMIT FROM THE ENGINEERING
 DEPARTMENT WILL BE REQUIRED FOR ALL WORK WITHIN THE
 CITY OF WEST PALM BEACH RIGHT-OF-WAY. THE APPLICATION
 FORMS AND CONSTRUCTION STANDARDS CAN BE FOUND AT
 HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL.
  
 1. SHOW THE DUMPSTER ENCLOSURE AREAS ON THE PLANS. THE
 PROPOSED LOCATIONS MUST BE EASILY ACCESSIBLE TO THE
 SOLID WASTE TRUCKS (35 FT LONG, 15 FT HIGH). THE DESIGN
 MUST COMPLY WITH SECTION 74-35(A)(9) OF THE CODE OF
 ORDINANCES. INCLUDE THE CITY OF WEST PALM BEACH GARBAGE
 RECEPTACLE DETAI ON THE PLANS. [CODE OF ORDINANCES,
 SECTION 94-444(B), FIGURE XIV-3]
  
 2. PROVIDE CALCULATIONS DEMONSTRATING THE PROPOSED SIZE
 AND QUANTITY OF TRASH BINS IS APPROPRIATE FOR THE WASTE
 YARDAGE ANTICIPATED TO BE GENERATED BY THE COMPLEX
  
 3. PROVIDE STORMWATER CALCULATIONS AND CONSTRUCTION
 PLANS. THE PROJECT MUST PROVIDE ADEQUATE STORMWATER
 MANAGEMENT, INCLUDING NOT MODIFYING THE VELOCITY OR
 VOLUME OF OFF-SITE STORMWATER DISCHARGE. COMPLIANCE
 WITH CHAPTER 40E-4 FAC WILL DEMONSTRATE COMPLIANCE WITH
 THIS PROVISION. [CODE OF ORDINANCES SECTIONS 90-201,
 94-35(C )(11), 94-307, AND 94-580]
  
 4. THE SUBMITTED SURVEY AND PLANS REFERENCE VERTICAL
 DATUM NAVD 1988. THE SECTION 78-9 OF THE CITY?S CODE OF
 ORDINANCES SPECIFIES NGVD 1929 AS THE OFFICIAL CITY
 VERTICAL DATUM. REVISE THE PLANS TO REFERENCE NGVD
 1929.
  
 5. STRIPING TO COMPLY WITH CITY OF WEST PALM BEACH CODE
 OF ORDINANCES, ARTICLE XV, SECTION 94-485. ADD A
 TYPICAL PARKING SPOT STRIPING DETAIL TO THE PLANS.
  
 6. REVISE THE PLANS TO SHOW THE EXISTING EASEMENTS OVER
 THE 48-INCH STORMWATER SYSTEM.
  
 7. SHOW THE EXTENT OF FLOOD ZONE AE ON THE SITE PLAN.
  
 8. THE PROPOSED BUILDING IS NOT WITHIN THE CITY OF WEST
 PALM BEACH POTABLE WATER SERVICE AREA. IF THE BUILDING
 IS NOT PROPOSED TO BE SERVED BY RIVIERA BEACH
 UTILITIES, PROVIDE A WRITTEN REQUEST FROM RIVIERA BEACH
 REQUESTING THAT SERVICE BE PROVIDED BY THE CITY OF WEST
 PALM BEACH.
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 ENGINEERING & PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
 [email protected]
 561-494-1098 (OFFICE)
  
  

Review Stop ENG-P ENGINEERING PLANNING REVIEW
Rev No 1 Status F Date 10-07-2014 Cont ID  
Sent By cranford Date 10-07-2014 Time 09:32 Rev Time 0.00
Received By cranford Date 10-06-2014 Time 15:55 Sent To  
Notes
2014-10-07 09:12:33ENGINEERING/PUBLIC WORKS DEPT.
 LAND DEVELOPMENT AND STORMWATER
 2ND REVIEW
  
 1. SECTION 78-9 OF THE CITY'S CODE OF ORDINANCES
 SPECIFIES NGVD 1929 AS THE OFFICIAL CITY VERTICAL
 DATUM. REVISE THE PLANS TO REFLECT THE OFFICIAL CITY
 VERTICAL DATUM.
  
 2. THE STRIPING DETAIL SHOWN ON SHEET C6.04 DOES NOT
 MEET THE REQUIREMENTS OF STALL PAINTING DETAIL INCLUDED
 IN SECTION 94-485 OF THE CITY'S CODE OF ORDINANCES.
 STALL PAINTING IS TO BE DOUBLE STRIPPED WITH 4 INCH
 LINES WITH A 12 INCH SEPARATION BETWEEN THE LINES.
 WHEEL STOPS MUST BE PROVIDED AS SHOWN IN FIGURE XIV-2
 OF SECTION 94-443 OF THE CODE OF ORDINANCES.
  
 3. PER DETAIL 21 ON SHEET C6.04 (CITY STANDARD DETAIL
 P-9), FORCEMAINS ARE TO ENTER THE RECEIVING MANHOLE AT
 180 DEGREES PLUS 10 DEGREES FROM THE GRAVITY OUTFLOW
 LINE. THE CONFIGURATION SHOWN ON SHEET C4.01 SHOWS THE
 ANGLE BETWEEN THE PROPOSED FORCE MAIN AND THE GRAVITY
 LINE TO BE APPROXIMATELY 140 DEGREES. REVISE THE
 CONFIGURATION SHOWN ON SHEET C4.01 TO MATCH THE DETAIL
 21.
  
 4. REVISE THE PLANS TO SHOW ALL EXISTING EASEMENTS,
 INCLUDING THE CITY'S EASEMENT OVER THE EXISTING
 DRAINAGE PIPE.
  
 5. VERIFY THAT THE "RIGHT TURN ONLY" SIGNS, SHOWN NEAR
 THE SOUTHWEST CORNER OF THE PARKING LOT, IS IN THE
 CORRECT LOCATION AND ORIENTATION. IT APPEARS THAT THE
 EASTERN MOST OF THE TWO SIGNS SHOULD BE ROTATED 90
 DEGREES, FACING THE WEST BOUND TRAFFIC AND THE OTHER
 SIGN IS INTENDED FOR SOUTH BOUND TRAFFIC AND SHOULD BE
 A "LEFT TURN ONLY" SIGN.
  
 6. THE PROPOSED BUILDING IS NOT WITHIN THE CITY OF WEST
 PALM BEACH POTABLE WATER SERVICE AREA. IF THE BUILDING
 IS NOT PROPOSED TO BE SERVED BY RIVIERA BEACH
 UTILITIES, PROVIDE A WRITTEN REQUEST FROM RIVIERA BEACH
 REQUESTING THAT SERVICE BE PROVIDED BY THE CITY OF WEST
 PALM BEACH.
  
 7. PRIOR TO START OF CONSTRUCTION, PERMITS WILL BE
 REQUIRED FOR THE CITY'S CONSTRUCTION SERVICE AND
 ENGINEERING DIVISIONS.
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 ENGINEERING & PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
 [email protected]
 561-494-1098 (OFFICE)

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 10-10-2014 Cont ID  
Sent By pleduc Date 10-10-2014 Time   Rev Time 0.00
Received By pleduc Date 10-10-2014 Time 10:46 Sent To  
Notes
2014-10-10 10:53:372ND REVIEW RESPONSE
  
 AFTER A REVIEW OF THE PPRC RESPONSE LETTER DATED
 9/15/14, FROM SONG & ASSOCIATES, TO ERIC SCHNEIDER,
 SENIOR PLANNER, THE PREVIOUSLY SUBMITTED FIRE
 PREVENTION BUREAU COMMENTS HAVE BEEN ADDRESSED.
 HOWEVER, AN AREA OF CONCERN THAT REMAINS IS A TURN
 AROUND OR (BACK-UP) LANE OFF OF THE ACCESS LANE IN
 FRONT OF THE BUILDING. THIS BACK-UP LANE WAS DISCUSSED
 AT AN ONSITE MEETING ON 9/25/14. THIS BACK-UP LANE IS
 REQUIRED AND SHOULD BE INCOPRATED INTO THE ANY FUTURE
 SUBMITTED DRAWINGS.
  
 THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT DOES
 NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL.
  
 THE BUREAU SHALL REVIEW ALL SUBMITTED BUILDING PLANS AT
 THE APPROPRIATE TIME AND IN ACCORDANCE WITH THE
 REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 09-08-2014 Cont ID  
Sent By pleduc Date 09-08-2014 Time   Rev Time 0.00
Received By pleduc Date 09-08-2014 Time 14:25 Sent To  
Notes
2014-09-08 14:55:56THE FOLLOWING COMMENTS WERE SUBMITTED BY PETER LEDUC,
 FIRE MARSHAL, BUREAU OF FIRE PREVENTION.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 THE FIRE PREVENTION BUREAU HAS NO OBJECTIONS TO THE
 PROPOSED PROJECT.
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241.
  
 2. SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 3. THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM
 ALL ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION.
 ADDRESS NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 4. TRASH AND DEBRIS IS TO BE REMOVED FROM THE SITE
 DAILY OR MORE OFTEN TO REDUCE THE ACCUMULATION OF
 POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 5. THE BUILDING CONSTRUCTON SHALL COMPLY WITH NFPA 101,
 LIFE SAFETY CODE, FLORIDA 2010 EDITION, INCLUDING
 CHAPTER 12, NEW ASSEMBLY OCCUPANCIES.
  
 6. A NFPA 13 COMPLAINT FIRE SPRINKLER SYSTEM IS
 REQUIRED FOR THIS STRUCTURE. SEPARATE SHOP DRAWINGS,
 ARE REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY
 THE FIRE PREVENTION BUREAU PRIOR TO ANY INSTALLATION.
  
 7. A MONITORED FIRE ALARM SYSTEM IS REQUIRED FOR THIS
 STRUCTURE. SEPARATE SHOP DRAWINGS, ARE REQUIRED TO BE
 SUBMITTED, REVIEWED AND APPROVED BY THE FIRE PREVENTION
 BUREAU PRIOR TO ANY INSTALLATION.
  
 8. PLEASE PROVIDE FIRE FLOW CALCULATIONS AND ENSURE THE
 PROPOSED FIRE HYDRANT IS SUFFICIENT TO PROVIDE THE
 FLOW.
  
 9. COMPLETE LIFE SAFETY PLANS FOR THE BUILDING SHALL BE
 PROVIDED THAT ILLUSTRATE OCCUPANT LOADS, TRAVEL
 DISTANCES, EXITS, EXIT DISCAHRGES, PUBLIC WAYS,
 EMERGENCY LIGHTING, DEAD-END CORRIDORS AND ALL FIRE
 SAFETY EQUIPMENT.
  
 10. OCCUPANT LOADS FOR ALL SPACES SHALL BE DETERMINED
 AND SUBMITTED WITH THE SUBMITTED PLAN AND WHEN APPROVED
 THEY ARE REQUIRED TO BE POSTED WHERE APPLICABLE.
  
 11. ALL PORTABLE FIRE EXTINGUISHERS LOCATIONS SHALL BE
 CLEARLY IDENTIFIED AND INDICATED ON THE PLAN.
  
 12. KNOX-BOX KEY SYSTEM SHALL BE REQUIRED FOR THIS
 BUILDING.
  
 13. ALL KITCHEN EQUIPMENT AND OPERATIONS SHALL COMPLY
 WITH NFPA 96, STANDARD FOR VENTILATION CONTROL AND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS.
 EXTINGUISHMENT AND VENTILATION SYSTEM SHOP DRAWINGS
 SHALL BE SUBMITTED SEPARATELY FOR APPROVAL.
  
 14. NOTICE IS REQUIRED FOR STRUCTURES WITH LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION. ANY COMMERCIAL, INDUSTRIAL, OR
 ANY MULTIUNIT RESIDENTIAL STRUCTURE OF THREE UNITS OR
 MORE WHICH USES HORIZONTAL OR VERTICAL LIGHT-FRAME
 TRUSS-TYPE CONSTRUCTION IN ANY PORTION SHALL BE MARKED
 WITH AN APPROVED SYMBOL. THE APPROVED SYMBOL SHALL BE
 PLACED WITHIN 24 INCHES TO THE LEFT OF THE MAIN ENTRY
 DOOR.
  
 15. THE ENTRY ACCESS ROAD SHOWS 16 FEETT AND THE ACCESS
 DRIVE IS 12 FEET WIDE. THESE ACCESS ROAD ARE FIRE LANES
 AND ARE REQUIRED TO BE 20 FEET WIDE.
  
 16. THE DOUBLE ENTRY GATES ARE REQUIRED TO HAVE KNOX
 KEY SWITCHES FOR 24 HOUR EMERGENCY ENTRY ACCESS.
  
  
  
  
  
  
  

Review Stop L LANDSCAPING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 3 Status F Date 12-19-2014 Cont ID  
Sent By tward Date 12-19-2014 Time 16:55 Rev Time 0.00
Received By tward Date   Time   Sent To  
Notes
2014-12-19 17:05:441. NOTE 4 ON SHEET C5.01 LISTS NAVD88.
  
 2. DRIVEWAY ON FLAGLER DRIVE AT SW CORNER OF SITE IS
 SHOWN TO GET NEW VALLEY GUTTER INSTEAD OF REPLACEMENT
 OF CURB WITH TYPE 'F' CURB AND GUTTER AND THE REMOVAL
 OF THE DRIVEWAY APRON BETWEEN THE CURB AND SIDEWALK.
 THIS WORK SHOULD ALSO BE SHOWN ON THE DEMOLOTION PLAN
 FOR CONTINUITY.
  
 3. PRIOPOSED STORM MISSING FROM THE LIGHTING AND
 PHOTOMETRICS PLANS.
  
 4. THERE IS NOT ANY "CONTROLS" IN STRUCTURE S-10 TO
 REGULATE STORMWATER RUNOFF INTO THE EXFILTRATION
 TRENCH. IT APPEARS EXFILTRATION TRENCH WILL BE
 SURCHARGED ONLY WHEN THE RETENTION AREA FILLS UP.
  
 5. SWPPP SHOULD INCLUDE PROTECTION OF INLETS ON FLAGLER
 DRIVE.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 PUBLIC WORKS DEPARTMENT
 561-494-1120

Review Stop STORM STORMWATER
Rev No 2 Status F Date 11-06-2014 Cont ID  
Sent By tward Date 11-06-2014 Time 15:45 Rev Time 0.00
Received By tward Date   Time   Sent To  
Notes
2014-11-06 16:22:431. RIGHT-OF-WAY PERMIT WILL BE REQUIRED FOR WORK ON N.
 FLAGLER DRIVE. CONSTRUCTION TO MEET CITY OF WEST PALM
 BEACH MINIMUM REQUIREMENTS AND FOLLOW CITY OF WEST PALM
 BEACH DETAILS AND SPECIFICATIONS.
  
 2. ANY CONSIDERATION GIVEN TO REMOVING THE CURB CUT ON
 N. FLAGLER DRIVE AT THE SOUTHWEST CORNER OF THE SITE
 AND CONSTRUCTING TYPE 'F' CURB AND GUTTER?
  
 3. DROP CURB SHOULD BE CONSTRUCTED ACROSS THE NEW
 DRIVEWAYS.
  
 4. TYPE 'D' CURBING ON EITHER SIDE OF DRIVEWAY APRON
 SHOULD NOT BE CONSTRUCTED WITHIN THE RIGHT-OF-WAY.
  
 5. PROVIDE DETAIL FOR EXFILTRATION TRENCH.
  
 6. LABEL AND PROVIDE A DETAIL FOR THE CONTROL STRUCTURE
 FOR SURCHARGING THE DRAINAGE SYSTEM AND EXFILTRATION
 TRENCH.
  
 7. CONSIDER PROVIDING A LEVEL SWALE BOTTOM AND WIDENING
 THE SIDE SLOPES AS THE ROAD SLOPES UP FROM THE LOW
 POINT.
  
 8. ARE THE SWALES CONNECTED TO THE DRAINAGE SYSTEM OR
 WILL THEY DRAIN THROUGH INFILTRATION?
  
 9. AT DRAINAGE STRUCTURE S-4, RAISE THE PAVEMENT SPOT
 GRADE OF 7.75 WEST OF THE STRUCTURE SO THAT THIS
 PORTION OF THE DRIVEWAY DRAINS EAST TO THE STRUCTURE.
  
 10. ON ALL OF THE PLAN SHEETS, SHOW THE PROPOSED
 EASEMENT OVER THE EXISTING 48" STORM PIPE.
  
 11. VERTICAL DATUM ON GRADING AND DRAINAGE PLAN SHOULD
 BE NGVD 1929 INSTEAD OF NAVD 1988 PER CITY CODE.
  
 12. SITE PLAN NEEDED WITH THE STORMWATER POLLUTION
 PREVENTION PLAN SHOWING THE LOCATIONS OF THE BMPS.
  
 13. SHOW EXISTING 48" STORM PIPE ON THE HARDSCAPE PLAN.
  
 14. PROPOSED LIGHTPOLE SLA2 SHOULD BE LOCATED OUTSIDE
 THE PROPOSED EASEMENT OVER THE EXISTING 48" STORM PIPE.
  
 15. SHOW PROPOSED UTILITIES ON THE LIGHTING AND
 PHOTOMETRIC PLAN.
  
 16. BOTTOM OF RETENTION BASIN SHOULD BE A MINIMUM OF
 12" ABOVE THE SEASONAL HIGH WATER ELEVATION.
  
 TRACY L. WARD, P.E.
 SR. STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 561-494-1120
  
  
  

Review Stop STORM STORMWATER
Rev No 1 Status F Date 09-10-2014 Cont ID  
Sent By tward Date 09-10-2014 Time 11:18 Rev Time  
Received By tward Date   Time   Sent To  
Notes
2014-09-10 11:24:091. NO PAVING, GRADING AND DRAINAGE PLAN PROVIDED.
  
 2. VERTICAL DATUM SHALL BE NGVD 1929. SURVEY SHOWS
 VERTICAL DATUM TO BE NAVD 1988.
  
 3. SUBMIT WITH ENGINEERING PERMIT APPLICATION:
 A. EROSION AND SEDIMENT CONTROL PLAN
 B. DRAINAGE AND LAND USE CALCULATIONS
  
 4. PRIOR TO START OF CONSTRUCTION, PROVIDE:
 A. SFWMD ERP OR ERP MODIFICATION
 B. FDEP NPDES STORMWATER CONSTRUCTION PERMIT
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 (561) 494-1120
  

Review Stop SURVEY SURVEYING
Rev No 3 Status F Date 12-23-2014 Cont ID  
Sent By vnoel Date 12-23-2014 Time 08:08 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2014-12-23 08:12:041. UNITY OF TITLE APPLICATION RECEIVED. OWNER CONTACTED
 FOR MISSING INFORMATION.
 2. EASEMENT INFORMATION PROVIDED TO OWNER. SHOW
 PROPOSED 25' DRAINAGE EASEMENT OVER EXISTING LINE ON
 ALL SHEETS.

Review Stop SURVEY SURVEYING
Rev No 2 Status F Date 10-16-2014 Cont ID  
Sent By vnoel Date 10-16-2014 Time 07:56 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2014-10-16 07:56:331. ELEVATIONS NEED TO BE REVISED. FORMULA FOR
 CONVERSION IS NOT ACCEPTABLE.
 2. INFORMATION CONCERNING EXISTING AND PROPOSED
 EASEMENT WAS SUPPLIED TO APPLICANT ON 9/19/14.
 3. ITEMS 3 THRU 5 OF FIRST SUBMITTAL STILL APPLY.

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 09-08-2014 Cont ID  
Sent By vnoel Date 09-08-2014 Time 09:21 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2014-09-08 09:33:171. SURVEY DOES NOT SHOW EXISTING DRAINAGE EASEMENTS.
 DATUM TO BE NGVD-29 PER CODE.
 2. PREVIOUS DISCUSSIONS INCLUDED THE TERMINATION OF
 EXISTING EASEMENTS AND THE GRANTING OF A NEW EASEMENT
 FOR THE DRAINAGE OUTFALL.
 3. SITE/CIVIL PLANS WILL REQUIRE A SEPARATE SUBMITTAL
 TO ENGINEERING SERVICES.
 4. CITY WILL REQUIRE REQUEST FROM RIVIERA BEACH IN
 ORDER TO PROVIDE WATER AND SEWER SERVICE PER INTERLOCAL
 AGREEMENT.
 5. UNITY OF TITLE WILL BE REQUIRED. APPLICATION IS MADE
 THROUGH ENGINEERING SERVICES.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status P Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By bcollins Date 09-09-2014 Time 11:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 02-12-2015 Cont ID  
Sent By eschneid Date 02-12-2015 Time 10:34 Rev Time 0.00
Received By eschneid Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 12-16-2014 Cont ID  
Sent By eschneid Date 12-16-2014 Time 15:58 Rev Time 0.00
Received By eschneid Date 12-16-2014 Time 15:58 Sent To  
Notes
2014-12-16 16:04:49CASE NO. ZBA 3311/ISPR 14-06 - RESUBMITTAL 11/21/14
 FPL MANATEE EDUCATION CENTER
 6000 NORTH FLAGLER DR.
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR
 (4) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE COMMENTS WITHIN 60 DAYS FROM
 THE DATE OF THE COMMENTS (BY FEBRUARY 16, 2014), THE
 CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER ACTION
 SHALL REQUIRE A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($200).
  
 1) REPEAT COMMENT: THE SURVEY SHALL SHOW ALL EXISTING
 EASEMENTS. STAFF NEEDS TO VERIFY THAT THERE ARE NO SITE
 FEATURES OR LANDSCAPING BEING INSTALLED IN CONFLICT
 WITH THE EASEMENTS.
  
 2) REPEAT COMMENT: THE CITY'S FIRE DEPARTMENT CONTINUES
 TO HAVE CONCERNS REGARDING THE EMERGENCY VEHICLE ACCESS
 TO THE BUILDING. THE ACCESS ISSUE NEEDS TO BE RESOLVED
 PRIOR TO SITE PLAN APPROVAL. PLEASE PROVIDE WRITTEN
 SIGN OFF OF THE FINAL EMERGENCY ACCESS LAYOUT FROM THE
 CITY'S FIRE DEPARTMENT.
  
 3) REPEAT COMMENT: THE ZONING AND LAND DEVELOPMENT
 REGULATIONS ONLY PERMIT A 20 SQUARE FOOT SIGN FOR THIS
 SITE. THE SIGN DETAIL SHOWS A SIGN THAT IS LARGER THAN
 20 SQUARE FEET, SINCE THE MANATEE THAT IS ATTACHED TO
 THE PANEL WITH THE TEXT HAS TO BE COUNTED AS PART OF
 THE SIGN AREA. THE SIDE MANATEE ON THE ROCKS ADJACENT
 TO THE SIGN ARE NOT COUNTED TOWARD THE SIGN AREA.
  
 4) REVISED COMMENT: PLEASE REMEMBER THE CONDITIONS OF
 CERTIFICATION REQUIRE THAT FPL SHALL ASSIST THE CITY IN
 CORRECTING THE LOCATION OF THE DRAINAGE EASEMENT SO
 THAT IT CORRESPONDS WITH THE LOCATION OF THE EXISTING
 DRAINAGE PIPE. PLEASE SHOW THE PROPOSED EASEMENT
 LOCATION (INFORMATION HAS BEEN PROVIDED TO FPL BY VINCE
 NOEL, CITY SURVEYOR) ON THE SITE PLAN SO THAT STAFF MAY
 VERIFY THAT THERE ARE NO CONFLICTS WITH SITE FEATURES
 AND LANDSCAPING.
  
  

Review Stop Z ZONING
Rev No 2 Status F Date 11-04-2014 Cont ID  
Sent By eschneid Date 11-04-2014 Time 13:43 Rev Time 4.00
Received By eschneid Date 11-04-2014 Time 13:43 Sent To  
Notes
2014-11-04 13:43:56CASE NO. ZBA 3311 - RESUBMITTAL 9/19/14
 FPL MANATEE EDUCATION CENTER
 6000 NORTH FLAGLER DR.
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR
 (4) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE COMMENTS WITHIN 60 DAYS FROM
 THE DATE OF THE COMMENTS (BY JANUARY 3, 2014), THE CASE
 SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL
 REQUIRE A NEW DEVELOPMENT APPLICATION.
  
 REPEAT COMMET: THE CONDITIONS OF CERTIFICATION REQUIRE
 THAT THE SITE PLAN BE REVIEWED AS AN INFORMAL SITE
 PLAN. THESE COMMENTS RELATE TO THE SITE PLAN; HOWEVER,
 FPL HAS NOT YET FILED THE INFORMAL SITE PLAN REVIEW
 APPLICATION. PLANS TO ADDRESS THE REMAINING COMMENTS
 SHALL BE FILED AS PART OF THE INFORMAL SITE PLAN
 REVIEW.
  
 1) REPEAT COMMENT: THE SURVEY SHALL SHOW ALL EXISTING
 EASEMENTS. STAFF NOTES THAT THE CURRENT DRAINAGE
 EASEMENT TRAVERSING EAST/WEST ACROSS THE SITE IS NOT
 SHOWN.
  
 2) REPEAT COMMENT: PLEASE REMEMBER THE CONDITIONS OF
 CERTIFICATION REQUIRE THAT FPL SHALL ASSIST THE CITY IN
 CORRECTING THE LOCATION OF THE DRAINAGE EASEMENT SO
 THAT IT CORRESPONDS WITH THE LOCATION OF THE EXISTING
 DRAINAGE PIPE.
  
 3) PARTIAL REPEAT: WHO IS PROVIDING EMERGENCY SERVICE
 TO THE MANATEE EDUCATION CENTER BUILDING? PROVIDE A
 TURNING RADIUS DRAWING VERIFYING THAT FIRE RESCUE
 VEHICLES, INCLUDING AMBULANCES, CAN ACCESS THE BUILDING
 VIA THE DRIVEWAY. SEE THE COMMENTS ISSUED BY THE FIRE
 DEPARTMENT REGARDING THE ACCESS TO THE BUILDING. THE
 ACCESS ISSUE NEEDS TO BE RESOLVED PRIOR TO SITE PLAN
 APPROVAL.
  
 4) NEW COMMENT: PLEASE EXPLAIN WHY THE SITE PLAN SHOWS
 A 20 FOOT WIDE STABILIZED FIRE TRUCK ACCESS ROAD, YET
 THE DETAIL ON SHEET C8.03 SHOWS ONE DETAIL WITH A 12
 FOOT WIDTH AND A DIFFERENT DETAIL WITH A 15 FOOT WIDTH.
  
 5) PARTIAL REPEAT: THE BUFFER LANDSCAPE REQUIREMENTS
 SHALL BE PROVIDED FOR ALL FOUR SIDES OF THE PROPERTY.
 PLEASE NOTE THAT THE DIMENSIONS USED TO CALCULATE THE
 BUFFERS SHALL MATCH THE SURVEY.
  
 A. THE NORTH BUFFER SHALL USE THE SURVEY DIMENSION
 LENGTH OF 463 FEET. THIS WILL REQUIRE 16 TREES - 16
 TREES ARE PROVIDED.
 B. THE SOUTH BUFFER SHALL USE THE SURVEY DIMENSION
 LENGTH OF 585 FEET. THIS WILL REQUIRE 20 TREES - 19
 TREES LISTED AS PROVIDED. STAFF RECOMMENDS A MEETING
 WITH THE LANDSCAPE ARCHITECT TO DISCUSS THE TREE COUNT,
 AS COUNTING TREES/PALMS FROM THE EAST AND WEST BUFFER
 INSTEAD ON THE SOUTH BUFFER MAY ACHIEVE THE REQUIRED
 TREE COUNT. THE EAST AND WEST BUFFER APPEAR TO EXCEED
 THE COUNTS.
 C. THE WEST BUFFER SHALL LIST THAT PALM TREES ARE
 COUNTED AT A 2:1 RATIO AS TREES.
  
 6) PARTIAL REPEAT: PLEASE INDICATE HOW THE 89 PROVIDED
 SHADE TREES WERE CALCULATED. THE PLANT SCHEDULE ONLY
 SHOWS 73 SHADE TREES. IF THE PALM SUBSTITUTION IS BEING
 USED (2:1) THEN PLEASE ANNOTATE THIS IN THE LANDSCAPE
 TABULATIONS.
  
 7) PARTIAL REPEAT: HOW WILL TRASH PICK-UP FOR THE
 BUILDING BE PROVIDED? PLEASE PROVIDE VERIFICATION FROM
 FERDINAND RIVERA-NEGRON, CITY SANITATION, APPROVING THE
 FPL PROPOSED TRASH PICK-UP PLAN OUTLINED IN THE E-MAIL
 TO PLANNING ON SEPTEMBER 19, 2014. HOW WILL RECYCLING
 BE ACHIEVED?
  
 8) NEW COMMENT: THE DETAILS FOR THE FENCE, GATES AND
 COLUMNS ALONG NORTH FLAGLER DRIVE SHOW THESE FEATURES
 TALLER THAN SIX (6) FEET. THE FENCE AND GATES ARE SHOWN
 WITH A SETBACK OF 25 FEET AND THE COLUMNS ARE SHOWN
 WITH AN APPROXIMATELY 24 FOOT SETBACK. THE ZONING AND
 LAND DEVELOPMENT REGULATIONS LIMIT FENCES IN
 RESIDENTIAL ZONING DISTRICTS TO FOUR (4) FEET IN HEIGHT
 WITHIN THE 25 FOOT FRONT SETBACK. IN ORDER TO HAVE THE
 FENCE, GATES AND COLUMNS AS SHOWN, THEY NEED TO BE
 FULLY LOCATED OUTSIDE OF THE 25 FOOT FRONT SETBACK.
  
 9) NEW COMMENT: THE ZONING AND LAND DEVELOPMENT
 REGULATIONS ONLY PERMIT A 20 SQUARE FOOT SIGN FOR THIS
 SITE. THE SIGN DETAIL SHOWS A SIGN THAT IS LARGER THAN
 20 SQUARE FEET.
  
 10) NEW COMMENT: THE BICYCLE RACKS THEMSELVES MEET CITY
 STANDARDS, HOWEVER; THE PLACEMENT OF THE RACKS ON THE
 PAD IN A LINEAR PATTERN DOES NOT SEEM TO PROVIDE
 FUNCTIONING BICYCLE PARKING. STAFF SUGGESTS USING THE
 ?HEAD IN? PARKING, AS SHOWN PREVIOUSLY. THIS REQUIRES A
 MINIMUM PAD DEPTH OF SIX (6) FEET. THE DIMENSIONS OF
 THE BICYCLE PAD, INCLUDING THE BICYCLE RACKS, ARE
 REQUIRED ON A DETAIL.
  
 11) NEW COMMENT: THE PARKING SPACE DETAILS THAT HAVE
 BEEN PROVIDED ON THE PLANS DO NOT CONFORM TO CITY OF
 WEST PALM BEACH STANDARDS. THE CITY REQUIRES DOUBLE
 STRIPING FOR THE PARKING SPACES IN ACCORDANCE WITH THE
 STALL PAINTING DETAIL FOUND IN SECTION 94-485 OF THE
 ZONING AND LAND DEVELOPMENT REGULATIONS.
  
 12) NEW COMMENT: THE MOUNTING HEIGHT ON THE PHOTOMETRIC
 PLAN LISTS THE SLC MOUNTING HEIGHT AT 14 FEET WHILE THE
 DETAILS SHEET SHOWS THEM AT 12 FEET. THIS WILL NEED TO
 BE CORRECTED AT TIME OF BUILDING PERMIT.
  

Review Stop Z ZONING
Rev No 1 Status F Date 09-10-2014 Cont ID  
Sent By eschneid Date 09-10-2014 Time 13:27 Rev Time 4.00
Received By eschneid Date 09-10-2014 Time 13:27 Sent To  
Notes
2014-09-10 13:27:38CASE NO. ZBA 3311
 FPL MANATEE EDUCATION CENTER
 6000 NORTH FLAGLER DR.
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF TEN
 (10) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - THE PPRC COMMENTS SHALL BE SUFFICIENTLY ADDRESSED AND
 SUBMITTED TO THE PLANNING DIVISION BY NOON ON MONDAY,
 SEPTEMBER 15, 2014, TO BE ELIGIBLE FOR SCHEDULING FOR
 THE OCTOBER 2, 2014 ZONING BOARD OF APPEALS MEETING.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS
 FROM THE DATE THE PPRC MEETING (BY NOVEMBER 10, 2014),
 THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER
 ACTION SHALL REQUIRE A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($324).
  
 THE CONDITIONS OF CERTIFICATION REQUIRE THAT THE USE OF
 THE SITE AS THE MANATEE EDUCATION CENTER (F.K.A.
 MANATEE VIEWING CENTER) BE REVIEWED BY THE ZONING BOARD
 OF APPEALS IN ACCORDANCE WITH THE CLASS B SPECIAL USE
 PERMIT REQUIREMENTS. ADDITIONALLY, THE CONDITIONS OF
 CERTIFICATION REQUIRE THAT THE SITE PLAN BE REVIEWED AS
 AN INFORMAL SITE PLAN. THIS PPRC MEETING WILL COMMENT
 ON BOTH THE USE AND THE SITE PLAN; HOWEVER, FPL HAS NOT
 YET FILED THE INFORMAL SITE PLAN REVIEW APPLICATION.
  
 1) THE SURVEY SHALL SHOW ALL EXISTING EASEMENTS. STAFF
 NOTES THAT THE CURRENT DRAINAGE EASEMENT TRAVERSING
 EAST/WEST ACROSS THE SITE IS NOT SHOWN.
  
 2) PLEASE REMEMBER THE CONDITIONS OF CERTIFICATION
 REQUIRE THAT FPL SHALL ASSIST THE CITY IN CORRECTING
 THE LOCATION OF THE DRAINAGE EASEMENT SO THAT IT
 CORRESPONDS WITH THE LOCATION OF THE EXISTING DRAINAGE
 PIPE.
  
 3) THE WALKWAY LEADING IN FROM FLAGLER DRIVE SHALL BE A
 MINIMUM OF EIGHT (8) FEET IN WIDTH.
  
 4) THE WALKWAY LEADING FROM THE DROP-OFF AREA TO THE
 WATERFRONT PROMENADE SHALL BE A MINIMUM OF EIGHT (8)
 FEET IN WIDTH.
  
 5) THE REMAINING WALKWAYS IN THE LAWN AREA TO THE EAST
 AND NORTH OF THE MANATEE SCULPTURE SHALL BE A MINIMUM
 OF SIX (6) FEET IN WIDTH.
  
 6) WHO IS PROVIDING EMERGENCY SERVICE TO THE MANATEE
 EDUCATION CENTER BUILDING? IF IT IS THE CITY OF WEST
 PALM BEACH, THEN 20 FOOT WIDE ACCESS AISLES ARE
 REQUIRED. ADDITIONALLY, PROVIDE A TURNING RADIUS
 DRAWING VERIFYING THAT FIRE RESCUE VEHICLES, INCLUDING
 AMBULANCES, CAN ACCESS THE BUILDING VIA THE DRIVEWAY.
  
 7) THERE SHALL BE TREES LINING THE WALKWAY LEADING IN
 FROM FLAGLER DRIVE TO PROVIDE SHADE TO PEDESTRIANS.
  
 8) PROVIDE THE DIMENSIONS FOR ALL THE DRIVE AISLES.
  
 9) THE CITY'S LANDSCAPE REGULATIONS REQUIRE THAT THE
 BUFFER HEDGE RUN THE LENGTH OF THE BUFFER. WHY HAVE
 SECTIONS BEEN LEFT EMPTY WITH OTHER SECTIONS HAVING A
 DOUBLE HEDGE?
  
 10) THE REQUIRED BUFFER LANDSCAPE REQUIREMENTS SHALL BE
 PROVIDED FOR ALL FOUR SIDES OF THE PROPERTY. PLEASE
 NOTE THAT THE DIMENSIONS USED TO CALCULATE THE BUFFERS
 SHALL MATCH THE SURVEY.
  
 11) THE LANDSCAPE TABULATIONS ARE NOT BASED ON THE
 CORRECT AMOUNT OF OPEN SPACE ON THE PORTION OF THE SITE
 IN WEST PALM BEACH. OPEN SPACE IS CALCULATED BY TOTAL
 PROPERTY AREA MINUS STRUCTURES. PAVED AREAS ARE
 INCLUDED AS PART OF THE OPEN SPACE CALCULATIONS. UPDATE
 THE TABLE ACCORDINGLY. PLEASE NOTE THAT TREES INSTALLED
 ON THE RIVIERA BEACH PORTION OF THE SITE WILL NOT COUNT
 TOWARD MEETING WEST PALM BEACH REQUIREMENTS.
  
 12) NOT ALL OF THE REQUIRED LANDSCAPE DATA HAS BEEN
 PROVIDED ON THE LANDSCAPE PLAN (EX. XERISCAPE TABLE,
 NUMBER OF SHADE TREES REQUIRED, NUMBER OF FLOWERING
 TREES REQUIRED, NUMBER OF SHRUBS REQUIRED, PARKING LOT
 LANDSCAPE REQUIREMENTS, ETC.). PLEASE REVIEW ARTICLE
 XIV, CHAPTER 94 OF THE CITY OF WEST PALM BEACH ZONING
 AND LAND DEVELOPMENT REGULATIONS.
  
 13) PROVIDE VERIFICATION THAT THE 38 TREES REMOVED HAVE
 BEEN REPLACED BY TREES THAT WILL PROVIDE EQUAL OR
 GREATER SIZE/CANOPY.
  
 14) THE OVERSIZE VEHICLE PARKING REQUIRES TERMINAL
 ISLANDS AT THE NORTH AND SOUTH ENDS, INCLUDING THE
 TERMINAL ISLAND TREE. THESE ISLANDS SHALL BE CURBED.
 ADDITIONALLY, D CURBING SHALL BE PROVIDED ALONG THE
 EAST SIDE OF THE SPACES TO PROTECT THE LAWN AREA FROM
 VEHICULAR ENCROACHMENT.
  
 15) HOW WILL TRASH PICK-UP FOR THE BUILDING BE
 PROVIDED?
  
 16) TRASH AND RECYCLING CONTAINERS SHALL BE PROVIDED.
  
 17) THE CITY SUGGESTS TEXTURED/COLORED ASPHALT FOR
 WHERE THE ADA/BICYCLE PARKING PATH CROSSES THE DRIVE TO
 THE BUILDING.
  
 18) PLEASE PROVIDE DETAILS ON THE FENCES, WALLS,
 PAVILION, LIGHT POLES AND THEIR FIXTURES, AND BICYCLE
 RACKS AND THE PAD. DIMENSIONS SHALL BE INCLUDED.
  
 19) THE LANDSCAPE PLAN SHOWS A TAG FOR TREE TYPE CE2,
 YET THE PLANT SCHEDULE ON SHEET C8.01 DOES NOT IDENTIFY
 THIS TYPE OF TREE.
  
 20) IS ANY ENTRY SIGNAGE PROPOSED?
  
 21) PARKING SPACE DETAILS ARE REQUIRED ON THE PLANS.
  

  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved