Plan Review Details - Project Z14080016
| Plan Review Stops For Project Z14080016 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
09-10-2014 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
09-10-2014 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
09-10-2014 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2014-09-10 11:38:54 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, | | | COMMENTS: | | | | | | NO COMMENTS ON THE PROPOSED RIGHT OF WAY ABANDONMENT. | | | | | | ROBERT BROWN | | | BUILDING OFFICIAL | | | TEL: 561 805 6652 | | | EMAIL: [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
|
Date |
09-10-2014 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
09-08-2014 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
09-08-2014 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2014-09-08 14:09:22 | THE FOLLOWING COMMENT WAS SUBMITTED BY PETER LEDUC, | | | FIRE MARSHAL, BUREAU OF FIRE PREVENTION. | | | | | | ANY FIRE LINE OR FIRE HYDRANT LOCATED WITHIN THE | | | RIGHT-OF-WAY SHALL BE RELOCATED TO ENSURE FIRE | | | DEPARTMENT ACCESS AND AVAILABILITY. |
|
|
| Review Stop |
STORM |
STORMWATER |
| Rev No |
1 |
Status |
F |
Date |
09-10-2014 |
|
|
Cont ID |
|
| Sent By |
tward |
Date |
09-10-2014 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
tward |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-09-10 11:07:08 | 1. DRAINAGE STRUCTURE (MANHOLE) WILL NEED TO BE | | | CONSTRUCTED ON THE EXISTING DRAINAGE SYSTEM AND LOCATED | | | EAST OF THE EAST END OF THE LIMITS OF THE14TH ST. R/W | | | ABANDONMENT. CITY'S MAINTENANCE RESPONSIBILITY WILL END | | | AT THE DRAINAGE STRUCTURE. APPLICANT WILL BE | | | RESPONSIBLE FOR MAINTNENANCE OF DRAINAGE SYSTEM TO THE | | | WEST OF THE DRAINAGE STRUCTURE. | | | | | | TRACY L. WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING AND PUBLIC WORKS DEPARTMENT | | | (561) 494-1120 | | | |
|
|
| Review Stop |
SURVEY |
SURVEYING |
| Rev No |
1 |
Status |
F |
Date |
09-08-2014 |
|
|
Cont ID |
|
| Sent By |
vnoel |
Date |
09-08-2014 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
vnoel |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-09-08 08:51:16 | 1.TWO SIGNED AND SEALED COPIES OF THE SKETCH AND LEGAL | | | DESCRIPTION ARE REQUIRED. | | | 2. CITY WILL OBTAIN QUOTE FOR APPRAISAL TO BE PAID FOR | | | BY APPLICANT. PLEASE NOTE THAT THE | | | APPRAISAL WILL BE AN "ACROSS THE FENCE" EVALUATION | | | BASED ON CURRENT PROPERTY VALUES. | | | 3. IT APPEARS THAT EASEMENTS WILL NEED TO BE RESERVED | | | FOR EXISTING UTILITIES. | | | 4. A T - TURNAROUND MAY BE REQUIRED AT GATE ON 14TH | | | STREET. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
01-02-2015 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
01-02-2015 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-01-02 10:47:48 | COMMENTS ADDRESSED IN CONJUCTION WITH SITE PLAN FOR | | | PATHFINDERS EUREKA CPD (PB1660 & 1660A). DK |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
09-10-2014 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
09-10-2014 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-09-10 08:32:35 | PLANNING AND ZONING COMMENTS: | | | | | | 1. SUBMIT THREE (3) COPIES OF A SIGNED AND SEALED | | | SURVEY OF THE AREA TO BE VACATED. SURVEYS PROVIDED WERE | | | NOT SIGNED. | | | | | | 2. PROVIDE COPIES OF REMAINING LETTERS FROM UTILITY | | | PROVIDERS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] |
|
|
| |