Plan Review Details - Project Z14030023
Plan Review Stops For Project Z14030023
Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 03-12-2014 Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
2014-03-12 09:28:55** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING. RESPOND TO THE COMMENTS
 IN WRITING AND/OR ON THE PLANS WHERE APPLICABLE:
  
 1.) PROVIDE A COPY OF THE LEASE AGREEMENT AND WRITTEN
 CONSENT FROM THE PROPERTY OWNER (FPL), ALLOWING THE
 WIRELESS CARRIER (AT&T) TO UTILIZE THE SITE FOR ANTENNA
 ATTACHMENTS.
  
 2.) THE PAD SHALL BE SETBACK AT LEAST 15 FT. FROM THE
 SIDE PROPERTY LINE. PLEASE ADDRESS. (ZLDR S.
 94-318(B)(1) AND S.94-208(A)(1))
  
 3.) EQUIPMENT SHELTERS OR CABINETS SHALL BE SCREENED
 FROM PUBLIC VIEW BY USING LANDSCAPING, OR MATERIALS AND
 COLORS CONSISTENT WITH THE SURROUNDING BACKDROP. (ZLDR
 S.94-324(A)(2)D.)
  
 4.) A LANDSCAPE OPAQUE BUFFER, IN ACCORDANCE WITH ZLDR
 ARTICLE XIV, S.94-443(2) LANDSCAPE BUFFER, SHALL BE
 PROVIDED AROUND THE INDIVIDUAL UTILITY FACILITIES OR
 AROUND THE PERIMETER OF THE UTILITY FACILITIES IN THEIR
 AGGREGATE OR AROUND THE PERIMETER OF THE PROPERTY.
 (ZLDR S.94-208(A)(6))
  
 5.) PLEASE CORRECT THE DISCREPANCY WITH THE HEIGHT OF
 THE PROPOSED TOWER ON SHEET C3. THE ELEVATION SHOWS 83
 FT. AND THE PROPOSED ANTENNA LAYOUT SHOWS 97 FT.
  
 6.) ALL FEED LINES SHALL BE INSTALLED INSIDE THE
 TRANSMISSION POLE SHAFT. (CITYSCAPE COMMENT)
  
 7.) EMERGENCY POWER GENERATOR SHALL BE TESTED ONLY
 BETWEEN THE HOURS OF 9 AM AND 4 PM MONDAY THROUGH
 FRIDAY. (CITYSCAPE COMMENT)
  
 8.) ALL ACCESS PORTS SHALL BE SEALED TO PREVENT ACCESS
 BY BIRDS AND OTHER WILDLIFE. (CITYSCAPE COMMENT)
  
 PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 IF YOU HAVE
 QUESTIONS.
  
 NOTE:
 - A SEPARATE LANDSCAPE PERMIT FOR THE REQUIRED
 LANDSCAPING WILL BE REQUIRED AT TIME OF PERMITTING.

  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved