Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 03-11-2014 Cont ID  
Sent By rbrown Date 03-11-2014 Time 20:17 Rev Time 0.00
Received By rbrown Date 03-11-2014 Time 20:17 Sent To  
Notes
2014-03-11 20:33:08DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR PERMITTING.
  
 2. PROXIMITY OF ACCESSIBLE PARKING. THE SURVEY DRAWING
 AND CIVEL ENGINEERING SHEETS C-1 AND C-2 SHOW THE
 ACCESSIBLE PARKING SPACES LOCATED SUCH THAT THEY ARE
 THE CLOSEST PARKING SPACES TO THE BUILDING ENTRANCE.
 SHEETS MP1.0, SP1.0 AND A1.0S ALL SHOW THE PROPOSED
 ACCESSIBLE PARKING SPACES FURTHER FROM THE BUILDING
 ENTRANCE SUCH THAT THEY WOULD NO LONGER BE THE CLOSEST
 PARKING SPACES TO THE BUILDING ENTRANCE. PER SECTION
 208.3 OF FLORIDA ACCESSIBILITY CODE ACCESSIBLE PARKING
 SPACES ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE
 OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE
 ENTRANCE FOR EACH BUILDING. THE DESIGN OF ACCESSIBLE
 PARKING SPACES SHALL COMPLY WITH SECTION 502 OF FLORIDA
 ACCESSIBILITY CODE
  
 3. CONSTRUCTION TYPE. WHEN SUBMITTED FOR BUILDING
 PERMIT, THE PLANS SHALL SHOW THAT THE TYPE OF
 CONSTRUCTION FOR THE BUILDINGS WILL BE IN ACCORDANCE
 WITH THE HEIGHT, AREA AND OCCUPANCY LIMITATIONS IN
 CHAPTER 5 OF THE FLORIDA BUILDING CODE
  
 4. BUILDING SEPARATION. WHEN SUBMITTED FOR BUILDING
 PERMIT, COMPLIANCE WITH ALL BUILDING SEPARATION,
 PERCENTAGE OF OPENINGS AND OPENING PROTECTIVE
 REQUIREMENTS OF CHAPTERS 6 AND 7 OF THE FLORIDA
 BUILDING CODE SHALL BE VERIFIED.
  
 5. ADDITION TO EXISTING BUILDING. THE ADDITION TO THE
 EXISTING BUILDING IS COVERED BY CHAPTER 10 OF THE
 FLORIDA EXISTING BUILDING CODE. THE HEIGHT AND/OR AREA
 INCREASE DUE TO THE PROPOSED ADDITION SHALL NOT
 INCREASE THE TOTAL BUILDING HEIGHT AND/OR AREA BEYOND
 THAT ALLOWED UNDER THE APPLICABLE PROVISIONS OF CHAPTER
 5 OF THE FLORIDA BUILDING CODE FOR THE TYPE OF
 CONSTRUCTION USED.
  
 6. ALL APPLICABLE PERMITS AND SUB-PERMITS MUST BE
 OBTAINED BEFORE COMMENCING THE WORK.
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status   Date 03-07-2014 Cont ID  
Sent By pleduc Date 03-07-2014 Time 16:49 Rev Time 0.00
Received By pleduc Date 03-07-2014 Time 16:47 Sent To  
Notes
2014-03-07 16:49:11PLEASE SEE THE NOTES FOR CASE # 14020011.
  
 PETER LEDUC, FIRE MARSHAL

Review Stop L LANDSCAPING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PARK PARKING
Rev No 1 Status P Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SURVEY SURVEYING
Rev No 2 Status P Date 04-08-2014 Cont ID  
Sent By vnoel Date 04-08-2014 Time 07:44 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
***NONE***

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 02-25-2014 Cont ID  
Sent By vnoel Date 02-25-2014 Time 13:16 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2014-02-25 13:41:151. ADD TIES FROM BUILDING TO PROPERTY LINES ON SURVEY.
 2. CITY DATUM IS NGVD-29. REVISE ALL PLANS ACCORDINGLY.
 3. SHOW LINE AND LABEL BEARING BASE BETWEEN THE 2
 MONUMENTS ON SURVEY.
 4. SITE/CIVIL PLANS WILL REQUIRE A SEPARATE SUBMITTAL
 TO ENGINEERING SERVICES.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By bcollins Date 04-07-2014 Time 16:53 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By dkittred Date 04-18-2014 Time 14:30 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 04-08-2014 Cont ID  
Sent By dkittred Date 04-08-2014 Time 11:09 Rev Time 0.00
Received By dkittred Date 03-25-2014 Time 10:47 Sent To  
Notes
2014-04-08 11:13:22PLANNING AND ZONING COMMENTS:
  
 4/8/2014
  
 COMMENTS TO BE ADDRESSED:
  
 1. THE EMAIL PROVIDED AS SUPPORT FOR THE COMMENT
 REGARDING THE SIDEWALK/PATHWAY BEING OUTSIDE THE LEASE
 AREA DOES NOT SPECIFICALLY ACKNOWLEDGE THE SIDEWALK
 WALK AND IT IS UNCLEAR IF THE VERSION OF THE SITE PLAN
 REVIEWED AND COMMENTED ON IN THE EMAIL CONTAINED THE
 SIDEWALK OUTSIDE THE LEASE AREA AT THAT TIME. PLEASE
 PROVIDE A RESPONSE FROM ST. MARY'S SPECIFICALLY
 INDICATING THIS WORK OUTSIDE THE LEASE AREA IS
 PERMITTED. (PREVIOUS COMMENT 9)
  
 2. PRELIMINARY LIGHTING HAS BEEN REVIEWED VIA EMAIL AND
 WAITING FOR FINAL PAPER SUBMITTAL. (PREVIOUS COMMENT
 16)
  
 3. DESIGN GUIDELINES (SECTION 2(G)) FOR THE ST. MARY'S
 CSPD REQUIRED THAT A MINIMUM OF 50% OF THE REQUIRED
 SHRUBS BE NATIVE TO PALM BEACH COUNTY OR DESIGNATED AS
 VERY DROUGHT TOLERANT. LANDSCAPE SHEET 1 OF 2 INDICATES
 THAT 100% OF THE REQUIRED SHRUBS ARE NATIVE, HOWEVER,
 LANDSCAPE SHEET 2 OF 2 DOES NOT INDICATE IN THE CHART
 THAT ANY OF THE SHRUBS ARE NATIVE. PLEASE CLARIFY THIS
 REFERENCE TO THE SHRUBS BEING NATIVE. OR WAS THE ITEM
 INTENDED TO MEAN THAT 100% OF THE REQUIRED SHRUBS ARE
 DROUGHT TOLERANT? IF CHANGES ARE REQUIRED BASED ON THE
 RESPONSE TO THIS ITEM PLEASE CONTACT ME TO DETERMINE IF
 THE CHANGE CAN BE ADDRESSED AT THE TIME OF SUBMITTAL OF
 THE LANDSCAPE PERMIT FOR THE SITE. (PREVIOUS COMMENT
 19)
  
 4. COMMENTS ON THE TREE ALTERATION PERMIT ARE UNDER
 PROJECT NUMBER Z14020013.
  
  
 CORRECTIONS THAT CAN BE MADE AT THE TIME OF SUBMITTAL
 OF A BUILDING/LANDSCAPE PERMIT:
  
 5. DISTANCE BETWEEN DOUBLE STRIPES ON THE PARKING
 DETAIL ON SHEET C-3 SHOULD BE 12" RATHER THAN 16". THE
 PLAN PACKET INCLUDES TWO STRIPING DETAILS IN THE
 PACKET. YOU MAY WANT TO OMIT ONE.
  
 6. BICYCLE PARKING SPACES PROVIDED IS 2 RATHER THAN 4.
 RACKS HOLD 1 BICYCLE EACH.
  
 7. CALCULATION FOR HANDICAP SPACES IS BASED ON THE
 TOTAL NUMBER OF SPACES PROVIDED, NOT THE MINIMUM
 PARKING REQUIRED BY CODE. AS A RESULT, 2 HANDICAP
 SPACES ARE REQUIRED AND 2 HAVE BEEN PROVIDED.
  
 8. THE LIVE OAK PROPOSED ON THE SOUTHEAST CORNER OF THE
 SITE NEEDS TO BE LOCATED ON THE NORTH SIDE OF THE
 SIDEWALK WITHIN THE LANDSCAPE PARKING ISLAND UNLESS
 JUSTIFICATION IS PROVIDED FOR ITS LOCATION.
 ADDITIONALLY, MOVING THE TREE MORE NORTHWARD WILL AVOID
 ANY VISUAL OBSTRUCTIONS AT THE TIME THE FUTURE
 CONNECTION ROAD IS CONSTRUCTED.
  
 9. IT APPEARS THAT LOCATIONS FOR THE AC UNITS HAVE BEEN
 IDENTIFIED ON THE PLANS WITH SQUARES, BUT THEY ARE NOT
 LABELED. SOME OF THESE 'SQUARES' HAVE LANDSCAPING
 PROPOSED OVER TOP OF THESE AREAS. PLEASE IDENTIFY THESE
 SQUARES AND CONFLICTS WITH THE LANDSCAPING. (PREVIOUS
 COMMENT 13)
  
 10. PER THE FIRE DEPT., THE FDC SHOULD BE MOVED TO THE
 SAME LOCATION AS THE PROPOSED FIRE HYDRANT NEAR THE
 DUMPSTER ENCLOSURE. (PLEASE CONTACT PETER LEDUC, FIRE
 MARSHAL WITH ANY QUESTIONS - (561)804-4709
 [email protected].)
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 03-05-2014 Cont ID  
Sent By dkittred Date 03-05-2014 Time 10:31 Rev Time  
Received By dkittred Date   Time   Sent To  
Notes
2014-03-12 10:32:17PLANNING AND ZONING COMMENTS:
  
 3/5/14
  
 SITE PLAN:
  
 1. PARKING STRIPING DETAIL NEEDS TO BE UPDATED (GRAPHIC
 WILL BE PROVIDED FOR REFERENCE).
  
 2. PROVIDE BICYCLE PARKING IN ACCORDANCE WITH ZLDR SEC.
 94-485(Q).
  
 3. PROVIDE LOADING AREA IN ACCORDANCE WITH ZLDR SEC.
 94-485(P).
  
 4. INCLUDE PARKING CALCULATION FOR HANDICAP ACCESSIBLE
 SPACES.
  
 5. THE LOT COVERAGE CALCULATION ON SHEET SP1.0 APPEARS
 TO BE THE LOT SIZE RATHER THAN LOT COVERAGE
 CALCULATION. PLEASE VERIFY.
  
 6. TRAFFIC CONCURRENCY LETTER FROM PALM BEACH COUNTY
 WILL BE REQUIRED BEFORE FINAL APPROVAL.
  
 7. MINIMUM HEIGHT OF DUMPSTER ENCLOSURE WALL IS SIX (6)
 FEET (ZLDR SEC. 94-444(B) FIGURE XIV-3). PLEASE CLARIFY
 PROPOSED HEIGHT OF DUMPSTER ON THE PLAN.
  
 8. PLEASE CLARIFY LEASE AREA VERSUS PROPERTY LINE.
  
 9. PLEASE CLARIFY THE EASTERN SIDEWALK LOCATION. IT
 APPEARS TO BE OUTSIDE THE LEASE AREA.
  
 10. THERE IS A SIDEWALK ON THE EAST SIDE OF THE
 HANDICAP PARKING SPACES PROVIDING A CONNECTION TO THE
 SOUTH. THIS CONNECTION IS ONLY SHOWN ON THE SITE PLAN
 (SP1.0) AND NOT CARRIED THROUGH TO THE OTHER SHEETS.
 PLEASE CORRECT.
  
 11. HOW WILL PEDESTRIANS USING THE SIDEWALK AROUND THE
 ROUNDABOUT BE PROTECTED FROM VEHICLES IN THE
 ROUNDABOUT? IS THE SIDEWALK RAISED?
  
 12. THE SIDEWALK ALIGNMENT IN THE LANDSCAPE ISLAND ON
 THE SOUTHEAST CORNER OF THE ROUNDABOUT IS NOT
 CONSISTENT BETWEEN THE SITE PLAN AND LANDSCAPE PLAN.
 ADDITIONALLY, A FIRE HYDRANT IS BEING PROPOSED ON THE
 UTILITY PLAN WITHIN THIS LANDSCAPE ISLAND WHICH WILL
 AFFECT THE PROPOSED PLANTINGS.
  
 13. WILL THERE BE ANY OTHER OUTDOOR MECHANICAL
 EQUIPMENT OR UTILITIES IN ADDITION TO THE GENERATOR AND
 TRANSFORMER SHOWN ON THE SITE PLAN SUCH AS POOL
 EQUIPMENT, AIR CONDITIONING UNITS, BACKFLOW PREVENTERS?
 IF SO, PLEASE INDICATE AND PROVIDE PROPER SCREENING.
 ADDITIONAL SCREENING SHOULD ALSO BE PROPOSED AROUND THE
 TRANSFORMER.
  
 14. WHAT IS THE TRAFFIC CONTROL PROPOSED FOR THE
 ALIGNMENT OF THE NEW DRIVEWAYS ON THE PLAN? HAS ANY
 CONSIDERATION BEEN MADE FOR THE TRAFFIC FLOW WITH THE
 FUTURE ENTRY ROAD ON THE MASTER PLAN?
  
 15. SITE PLAN INDICATES THE EXISTING FREESTANDING SIGN
 TO BE RELOCATED. PLEASE INCLUDE ON THE SITE PLAN WHERE
 THE FREESTANDING SIGN WILL BE RELOCATED TO SO IT CAN BE
 ACCOUNTED FOR IN THE MINOR PD AMENDMENT. IF A NEW
 FREESTANDING SIGN WILL BE CONSTRUCTED RATHER THAN
 RELOCATED, COMPLIANCE WITH THE ST. MARY'S CSPD MASTER
 SIGNAGE PROGRAM WILL NEED TO BE DEMONSTRATED.
 A NEW 3' X 2' DIRECTIONAL PARKING SIGN IS BEING
 PROPOSED ON THE SOUTH PORTION OF THE SITE. ADDITIONAL
 DESIGN INFORMATION IS NEEDED ON THIS SIGN TO EVALUATE
 CONSISTENCY OF THIS SIGN WITH THE MASTER SIGNAGE PLAN
 FOR ST. MARY'S CSPD.
  
 16. PLEASE REVIEW LIGHTING GUIDELINES OF THE ST. MARY'S
 CSPD AND DEMONSTRATE COMPLIANCE WITH THE REQUIREMENTS
 OR NOTATE WHERE THE PLAN DEVIATES FROM THE GUIDELINES.
 IT WILL BE IMPORTANT THAT THE PROPOSED LIGHTING
 FIXTURES ARE AESTHETICALLY COMPATIBLE WITH WHAT IS
 EXISTING ON THE ST. MARY'S CAMPUS.
  
 17. TREE ALTERATION PERMIT WAS RECEIVED BUT IT ONLY
 CONTAINED A LIST OF TREES TO BE REMOVED. A SITE PLAN
 INDICATING THE LOCATION OF THE TREES TO BE REMOVED AND
 CALCULATION FOR REPLACEMENT WILL NEED TO BE SUBMITTED
 PER ZLDR SEC. 94-448.
  
 LANDSCAPING:
  
 18. 75% OF REQUIRED TREES ARE TO BE SHADE TREES. SHEET
 1 OF 2 OF THE LANDSCAPE PLAN INDICATES ONLY 63% IS
 PROVIDED. IS THERE A REASON THE 75% CANNOT BE MET?
  
 19. THE DESIGN GUIDELINES (SECTION 2(G)) FOR THE ST.
 MARY'S CSPD REQUIRE THAT A MINIMUM OF 75% OF THE TREES
 AND PALMS REQUIRED BY CODE AND THE GUIDELINES BE NATIVE
 TO PALM BEACH COUNTY. SIMILARLY A MINIMUM OF 50% OF THE
 SHRUBS REQUIRED TO BE INSTALLED SHALL BE NATIVE TO PALM
 BEACH COUNTY.
  
 20. LOCATION OF UTILITIES THAT MAY IMPACT THE PLANTINGS
 SHOULD BE DEPICTED ON THE LANDSCAPE PLAN WHICH INCLUDES
 BUT IS NOT LIMITED TO LOCATION OF UTILITY AND DRAINAGE
 EASEMENTS, OVERHEAD LINES, WATER METERS, TRANSFORMERS
 CHECK VALVES, CLEAN-OUTS, FIRE HYDRANTS, LIGHT POLES,
 ETC.
  
 21. THE DIVIDER MEDIAN LANDSCAPE AREA ON THE WESTERN
 SIDE OF THE PARKING LOT SHALL BE A MINIMUM OF 5' IN
 WIDTH EXCLUDING THE CURBING.
  
 22. PLEASE REVIEW AND VERIFY COMPLIANCE WITH SECTION
 6(D) REQUIRED PLANT MATERIAL SPECIFICATIONS OF THE ST.
 MARY'S CSPD REGARDING PLANT HEIGHT, CLEAR TRUNK, AND
 SPREAD REQUIREMENTS.
  
 GENERAL COMMENTS FOR RESUBMITTING:
  
 A. PROVIDE WRITTEN RESPONSES TO REVIEW COMMENTS MADE BY
 DEPARTMENTS IN A WRITTEN FORMAT WHEN RESUBMITTING.
  
 B. 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE
 PROVIDED, ALONG WITH ONE REDUCED COPY AND AN ELECTRONIC
 COPY OF ALL PLANS. YOU MAY VERIFY PRIOR TO RESUBMITTAL
 IF A REDUCED NUMBER PLANS CAN BE SUBMITTED.
  
 C. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
  
 D. PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
  