Plan Review Details - Project Z13070045
Plan Review Stops For Project Z13070045
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 08-13-2013 Cont ID  
Sent By rbrown Date 08-13-2013 Time 20:30 Rev Time 0.00
Received By rbrown Date 08-13-2013 Time 20:30 Sent To  
Notes
2013-08-13 20:53:05DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR PERMITTING.
  
 2. WHEN SUBMITTED FOR PERMIT, THE PLANS SHALL SHOW AT
 LEAST ONE ACCESSIBLE ROUTE, COMPLYING WITH SECTIONS
 206.2 AND 402.2 OF FLORIDA ACCESSIBILITY CODE, FROM THE
 PUBLIC RIGHT-OF-WAY TO ALL ACCESSIBLE BUILDING OR
 FACILITY ENTRANCES.
  
 3. SHOW AT LEAST ONE ACCESSIBLE ROUTE, COMPLYING WITH
 SECTIONS 206.2 AND 402.2 OF FLORIDA ACCESSIBILITY CODE,
 CONNECTING ACCESSIBLE BUILDING OR FACILITY ENTRANCES
 WITH ALL ACCESSIBLE SPACES AND ELEMENTS WITHIN THE
 BUILDING OR FACILITY
  
 4. ANY PART OF AN ACCESSIBLE ROUTE WITH A SLOPE GREATER
 THAN 1:20 SHALL BE CONSIDERED A RAMP AND SHALL COMPLY
 WITH SECTION 405 OF FLORIDA ACCESSIBILITY CODE.
  
 5. PER SECTION 208.3 OF FLORIDA ACCESSIBILITY CODE
 ACCESSIBLE PARKING SPACES ARE TO BE LOCATED ON THE
 SHORTEST POSSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING
 TO AN ACCESSIBLE ENTRANCE FOR EACH BUILDING. THE DESIGN
 OF ACCESSIBLE PARKING SPACES SHALL COMPLY WITH SECTION
 502 OF FLORIDA ACCESSIBILITY CODE
  
 6. THE TYPE OF CONSTRUCTION FOR THE BUILDINGS IS NOT
 STATED ON THE PLANS AT THIS STAGE. THE CONSTRUCTION
 TYPE SHALL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND
 OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA
 BUILDING CODE.
  
 7. COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE
 OF OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF
 CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE
 VERIFIED.
  
 8. FOR THE PROPOSED "DIESEL FUEL STORAGE FACILITY", THE
 STORAGE CAPACITY, VEHICLE IMPACT PROTECTION, AND FULL
 DESIGN DETAILS WILL BE REQUIRED FOR PERMITTING.
  
 9. ALL APPLICABLE PERMITS MUST BE OBTAINED BEFORE
 COMMENCING THE WORK.
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 08-01-2013 Cont ID  
Sent By mcarsill Date 08-01-2013 Time 06:22 Rev Time 0.00
Received By mcarsill Date 08-01-2013 Time 05:56 Sent To  
Notes
2013-08-01 06:22:37PLANNING BOARD CASE NO. 1639 (Z13070045)
 1009 BANYAN BOULEVARD
 DEVELOPMENT OF SIGNIFICANT IMPACT (DSI)
 CONSTRUCT AN EXPANSION TO THE EXISTING WATER TREATMENT
 PLANT AND RELATED SITE IMPROVEMENTS
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS
 COMPLETE DRAWINGS WERE NOT PROVIDED. ADDITIONAL
 COMMENTS CAN BE EXPECTED WHEN COMPLETE DRAWINGS ARE
 SUBMITTED.
  
 1. PLEASE SUBMIT COMPLETE ARCHITECTURAL, MECHANICAL,
 ELECTRICAL, PLUMBING, FIRE SPRINKLER AND FIRE ALARM
 PLANS TO THE CONSTRUCTION SERVICES DEPARTMENT FOR
 REVIEW.
  
 2. THE NEW FIRE HYDRANT LOOP DISPLAYED ON SHEET C-2 IS
 TO BE GIVEN CONSTRUCTION PRIORITY FOR INSTALLATION.
  
 3. ALL DEMOLITION, RENOVATION, AND CONSTRUCTION TO
 COMPLY WITH NFPA 241.
  
 4. SUITABLE ACCESS LANES AND ROADS SHALL BE PROVIDED
 FOR FIRE RESCUE USE DURING CONSTRUCTION AND RELOCATION
 ACTIVITIES AT THE PLANT.
  
 5. ALL ELECTRICAL WORK IS COMPLY WITH NFPA 70, THE
 NATIONAL ELECTRICAL CODE.
  
 6. ALL CHEMICALS ASSOCIATED WITH PLANT OPERATIONS ARE
 TO BE STORED, HANDLED, PROCESSED, AND TRANSFERED PER
 RECOGNIZED SAFETY REGULATIONS AND STANDARDS.
  
 7. THE INSTALLATION OF ANY LANDSCAPING SHALL NOT
 INTERFERE WITH ACCESS TO ANY FIRE PROTECTION SYSTEMS OR
 DEVICES.
  
 8. MORE DETAILS NEEDED ON THE "VEHICULAR ACCESS
 RESTRICTION DEVICES" REFERENCED ON SEVERAL SHEETS OF
 THE DRAWINGS.
  
 DENIED
  
  
 MICHAEL E. CARSILLO, ASSISTANT FIRE CHIEF
 WEST PALM BEACH FIRE RESCUE

Review Stop L LANDSCAPING
Rev No 1 Status N Date 08-14-2013 Cont ID  
Sent By jroach Date 08-14-2013 Time 12:42 Rev Time 0.00
Received By jroach Date 08-14-2013 Time 12:42 Sent To  
Notes
2013-08-14 12:43:32SEE COMMENTS CONTAINED WITHIN THE "ZONING" REVIEW STOP.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL
 PLANNER, AT (561) 822-1448.

Review Stop PARK PARKING
Rev No 1 Status F Date 08-13-2013 Cont ID  
Sent By ssamuels Date 08-13-2013 Time 17:41 Rev Time 0.00
Received By ssamuels Date 08-13-2013 Time 17:33 Sent To  
Notes
2013-08-13 17:36:59PLEASE PROVIDE PARKING DATA SHOWING ALL SPECIFICATION
 FOR ADA AND REGULAR PARKING SPACES.
 ADA - PARKING SIGN, SYMBOL, ASILE ETC. ACCORDINGLY WITH
 THE CITY OF WEST PALM BEACH ZONING AND AND
 LAND DEVELOPMENT REGULATION.

Review Stop POLICE POLICE
Rev No 1 Status F Date 08-05-2013 Cont ID  
Sent By   Date 08-05-2013 Time   Rev Time 0.00
Received By ktucker Date 08-05-2013 Time 10:28 Sent To  
Notes
2013-08-05 10:29:10CONDITIONS FOR APPROVAL
 PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE
 APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY
 AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST
 PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL.
 A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION
 TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE
 SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES
 FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT
 BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL,
 VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS,
 REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE
 SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF
 WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER
 MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE
 WORKING ENVIRONMENT.
 B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED
 THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT.
 NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A
 STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT
 DEVELOPMENT.
 C. PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY
 500 FEET AROUND THE PERIMETER OF THE SITE.
  
 DOORS
 A. EXTERIOR DOORS SHALL ALL BE EQUIPPED WITH SECURITY
 HINGES AND SHALL BE REINFORCED WITH CASE HARDENED
 STRIKE PLATES. CASE HARDENED DEADBOLT LOCKS SHALL BE
 PROVIDED ON ALL EXTERIOR DOORS WITH A MINIMUM (1) INCH
 THROW OR MECHANICAL INTERLOCK.
 B. GLASS PERIMETER DOORS SHALL BE EQUIPPED WITH CASE
 HARDENED GUARD RINGS TO PROTECT THE MORTISE LOCK
 CYLINDER.
 C. REAR DOORS SHALL BE EQUIPPED WITH 180-DEGREE
 PEEPHOLE/ SECURITY VIEWER.
 DESIGN
 A. BUILDING ARCHITECTURE SHALL ALLOW FOR ENHANCED
 NATURAL SURVEILLANCE OF ALL PARKING LOTS AND PROVIDE A
 SENSE OF SECURITY TO EMPLOYEES AND VISITORS.
 B. ALL BUILDINGS SHALL BE PRE-WIRED FOR CLOSED-CIRCUIT
 TELEVISION (CCTV) AND ALARM SYSTEMS.
 C. SIGNS SHALL CLEARLY IDENTIFY PUBLIC ENTRANCES.
 D. LANDSCAPING SHALL BE MAINTAINED AT 3 FEET OR LESS.
 TREES SHALL BE INSTALLED SO AS NOT TO CONFLICT WITH THE
 LIGHTING SYSTEM. LOWER CANOPY LIMBS ON TREES SHALL BE
 MAINTAINED AT 8 FEET OR HIGHER. LANDSCAPING SHALL NOT
 OBSTRUCT VIEW FROM WINDOWS OR WALKWAYS
 E. CONVEX MIRRORS SHALL BE INSTALLED IN STAIRWELL
 ENABLING VIEWS OF UPPER AND LOWER STAIRWAYS.
 F. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR
 ABOVE OR NEAR ENTRYWAYS TO BUILDINGS FOR DUSK TO DAWN
 OPERATION SHALL BE PROVIDED.
 G. BUILDING LIGHTING (NON-GLARE) SHALL BE AROUND
 PERIMETER ON ALL SIDE.
 H. ACCESS SHOULD BE CONTROLLED IN THE LOBBY, PLACE A
 DOOR WITH ACCESS CONTROL LEADING INTO THE OFFICE AREAS.
 I. ROOF LADDERS MUST BE RETRACTABLE, PAD LOCKED LADDER
 GUARD OR MESH LINED CAGE TO PREVENT ROOF ACCESS.
 J. BENCHES SHALL BE DIVIDED STYLE.
  
  

Review Stop PW PUBLIC WORKS
Rev No 1 Status F Date 08-12-2013 Cont ID  
Sent By jroach Date 08-12-2013 Time 20:51 Rev Time 0.00
Received By jroach Date 08-12-2013 Time 20:51 Sent To  
Notes
2013-08-12 20:52:33THE FOLLOWING COMMENTS WERE ISSUED BY FERDINAND RIVERA
 NEGRON, SANITATION SUPERINTENDENT, VIA EMAIL ON
 08/07/2013...
  
 DOES NOT SHOWS ANY DUMPSTERS LOCATIONS. SO I CANNOT
 ASSESS THEIR PLANS, WE ARE CURRENTLY PROVIDING
 DUMPSTERS SERVICES WITHOUT ANY TYPE OF PROBLEMS.

Review Stop STORM STORMWATER
Rev No 1 Status P Date 08-12-2013 Cont ID  
Sent By tward Date 08-12-2013 Time 15:14 Rev Time  
Received By tward Date 08-12-2013 Time   Sent To  
Notes
2013-08-12 15:12:491. CIVIL PLANS NOT SIGNED AND SEALED.
 2. TEMPORARY STORMWATER POND TO BE SIZED TO PROVIDE
 REQUIRED MINIMUM WATER QUALITY TREATMENT.
 3. PROVIDE COPY OF SFWMD ERP PERMIT WITH ENGINEERING
 PERMIT APPLICATION.
 4. SIGNED AND SEALED ENGINEERING PLANS TO BE SUBMITTED
 WITH THE ENGINEERING PERMIT APPLICATION.
 5. STORM WATER POLLUTION PREVENTION PLAN TO BE
 SUBMITTED WITH THE ENGINEERING PERMIT APPLICATION.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 (561) 494-1120

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 08-12-2013 Cont ID  
Sent By   Date 08-12-2013 Time   Rev Time  
Received By   Date 08-12-2013 Time   Sent To  
Notes
2013-08-12 07:50:151. THERE IS AN UPDATED SURVEY BY MRA WHICH SHOWS A 15'
 COUNTY DE ALONG AUSTRALIAN AVE, THIS MAY CONFLICT WITH
 PROPOSED WALL AND LANDSCAPING. SHOW ON ALL PLANS.
 2. CONSTRUCTION OF NEW RETENTION AREAS IN FPL EASEMENTS
 WILL REQUIRE FPL APPROVAL. IT APPEARS THEIR EXISTING
 OUTFALL IS TO BE REMOVED.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status P Date   Cont ID  
Sent By   Date 08-12-2013 Time   Rev Time 0.00
Received By bcollins Date 08-12-2013 Time 15:16 Sent To  
Notes
2013-08-12 15:15:52NO COMMENTS

Review Stop Z ZONING
Rev No 1 Status F Date 08-14-2013 Cont ID  
Sent By jroach Date 08-14-2013 Time 12:42 Rev Time 0.00
Received By jroach Date 08-14-2013 Time 12:42 Sent To  
Notes
2013-08-14 12:42:44ZONING PLANS AND PLATS REVIEW COMMITTEE (PPRC) REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 08.14.2013
 PROJECT NO.: Z13070045
 CASE NO.: PB 1639
 ADDRESS: 1009 BANYAN BOULEVARD
 APPLICANT/CONTACT: GERARDUS SCHERS
 TELEPHONE NO.: 561.650.0070
 SCOPE OF REVIEW: EXPANSION TO THE CITY?S WATER
 TREATMENT PLANT.
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS:
  
 1. THE DRAWINGS SUBMITTED WERE NOT TOO SCALE.
  
 2. PLEASE PROVIDE A CLEAN SITE PLAN THAT DOES NOT SHOW
 BELOW-GROUND IMPROVEMENTS. THIS CAN BE PROVIDED IN
 ADDITION TO THE PIPING PLAN. THE SITE PLAN SHALL ALSO
 INCLUDE THE FOLLOWING:
  
 A. SETBACKS TO BUILDINGS/STRUCTURES
 B. CLEAR LABELING ALL ABOVE-GROUND IMPROVEMENTS (SOME
 LABELS MISSING ON THE PLANS SUBMITTED)
 C. DIMENSIONS OF BUILDINGS
 D. FLOOR AREA OF BUILDINGS
 E. NUMBER OF STORIES/BUILDING HEIGHTS
 F. DETAILS OF SIGNS
 G. LOCATIONS AND HEIGHTS OF ALL EXISTING AND PROPOSED
 FENCING
 H. DIMENSIONS OF PARKING SPACES
 I. STANDARD DETAILS FOR DUMPSTER ENCLOSURES AND PARKING
 SPACES (STRIPING)
  
 3. THE AMOUNT OF OPEN SPACE SHOULD BE CALCULATED AS THE
 TOTAL LOT AREA MINUS BUILDINGS.
  
 4. LANDSCAPING + IMPERVIOUS + RETENTION/LAKE AREAS
 SHOULD EQUAL 100%.
  
 5. THE BOUNDARIES OF EAST CLEAR LAKE, FENCING, ETC.
 APPEAR TO BE MISSING.
  
 6. THE AMOUNT OF LANDSCAPE MATERIAL SHOULD BE BASED
 UPON THE AMOUNT OF REQUIRED OPEN SPACE (30% OF THE
 TOTAL LOT AREA IS 772,972 SQUARE FEET). ADJUST
 LANDSCAPE CALCULATIONS ACCORDINGLY.
  
 7. PLEASE PROVIDE A XERISCAPE TABLE INDICATING
 COMPLIANCE WITH ARTICLE XIV OF THE CITY?S ZONING AND
 LAND DEVELOPMENT REGULATIONS.
  
 8. SHADE/FLOWERING TREES SHOULD BE A MINIMUM OF 10 FEET
 IN HEIGHT AND 5 FEET CLEAR TRUNK.
  
 9. IS A WALKING PATH PROPOSED AROUND THE RENTENTION
 AREA? BENCHES AND LANDSCAPING ARE SHOWN BUT IT IS
 UNCLEAR AS TO HOW THESE AREAS ARE ACCESSED.
  
 10. IS NO NEW PLANTING PROPOSED ALONG THE NORTH SIDE OF
 THE ACCESS ROAD?
  
 11. PLEASE PROVIDE COPIES OF THE REMAINING UTILITY
 LETTERS.
  
 12. PLEASE PROVIDE A SIGNED/NOTARIZED COPY OF THE
 MAILING LIST AFFIDAVIT.
  
 ___________________________________________
  
 PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING:
  
 A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL
 DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION.
  
 B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE
 PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X
 17IN), AND AN ELECTRONIC COPY OF ALL PLANS.
  
 C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO
 ADDITIONAL COMMENTS.
  
 D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
  
 E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
  
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1448
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.WPB.ORG
  