Plan Review Details - Project Z13070040
Plan Review Stops For Project Z13070040
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 08-13-2013 Cont ID  
Sent By rbrown Date 08-13-2013 Time 21:06 Rev Time 0.00
Received By rbrown Date 08-13-2013 Time 21:06 Sent To  
Notes
2013-08-13 21:15:40DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION,
 COMMENTS:
  
 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE
 SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH
 FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE
 ADDRESSED FOR PERMITTING.
  
 2. THE SUBMITTED PLAN DOES NOT MAKE IT CLEAR WHERE THE
 ACCESSIBLE ENTRANCE TO THE CHURCH BUILDING IS LOCATED
 AND HOW THE RECONFIGURED PARKING LOT AFFECTS ACCESS TO
 THAT ENTRANCE. WHEN SUBMITTED FOR PERMIT, THE PLANS
 SHALL SHOW THAT THE RECONFIGURED PARKING LOT PROVIDES
 FOR AT LEAST ONE ACCESSIBLE ROUTE, COMPLYING WITH
 SECTIONS 206.2 AND 402.2 OF FLORIDA ACCESSIBILITY CODE,
 FROM THE PUBLIC RIGHT-OF-WAY TO ALL ACCESSIBLE BUILDING
 OR FACILITY ENTRANCES.
  
 3. THE SUBMITTED PLAN DOES NOT MAKE IT CLEAR WHERE THE
 ACCESSIBLE ENTRANCE TO THE CHURCH BUILDING IS LOCATED
 AND HOW THE RECONFIGURED PARKING LOT AFFECTS ACCESS TO
 THAT ENTRANCE. THERE ARE THREE STEPS SHOWN AT THE SOUTH
 END OF THE BUILDING. ANY PART OF AN ACCESSIBLE ROUTE
 WITH A SLOPE GREATER THAN 1:20 SHALL BE CONSIDERED A
 RAMP AND SHALL COMPLY WITH SECTION 405 OF FLORIDA
 ACCESSIBILITY CODE.
  
 4. THE SUBMITTED PLAN DOES NOT MAKE IT CLEAR WHERE THE
 ACCESSIBLE ENTRANCE TO THE CHURCH BUILDING IS LOCATED
 AND HOW THE RECONFIGURED PARKING LOT AFFECTS ACCESS TO
 THAT ENTRANCE. PER SECTION 208.3 OF FLORIDA
 ACCESSIBILITY CODE ACCESSIBLE PARKING SPACES ARE TO BE
 LOCATED ON THE SHORTEST POSSIBLE ROUTE OF TRAVEL FROM
 ADJACENT PARKING TO AN ACCESSIBLE ENTRANCE FOR EACH
 BUILDING. THE DESIGN OF ACCESSIBLE PARKING SPACES SHALL
 COMPLY WITH SECTION 502 OF FLORIDA ACCESSIBILITY CODE.
  
 5. ALL APPLICABLE PERMITS MUST BE OBTAINED BEFORE
 COMMENCING THE WORK.
  
 ROBERT BROWN
 BUILDING OFFICIAL
 TEL: 561 805 6652
 EMAIL: [email protected]
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 07-31-2013 Cont ID  
Sent By mcarsill Date 07-31-2013 Time 16:30 Rev Time 0.00
Received By mcarsill Date 07-31-2013 Time 16:07 Sent To  
Notes
2013-07-31 16:30:23INFORMAL SITE PLAN REVIEW CASE NO. 13-06 (Z13070040)
 NEW BETHEL MISSIONARY BAPTIST CHURCH
 32 NEW PARKING SPACES
 ANA MARIA APONTE, CITY URBAN DESIGNER
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY SINCE
 COMPLETE PLANS AND DRAWINGS WERE NOT PROVIDED.
 ADDITIONAL COMMENTS MAY BE PROVIDED IN THE FUTURE WHEN
 COMPLETE PLANS ARE SUBMITTED.
  
 1. ALL DEMOLITION, RENOVATION, AND CONSTRUCTION TO
 COMPLY WITH NFPA 241.
  
  
 MICHAEL E. CARSILLO, ASSISTANT FIRE CHIEF
 WEST PALM BEACH FIRE RESCUE

Review Stop L LANDSCAPING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By ktucker Date 08-02-2013 Time 14:09 Sent To  
Notes
2013-08-02 14:10:23PLEASE SHOW LIGHTING, EXISTING OR ADDITIONAL FOR THIS
 PARKING LOT
  
 11/13/13 NO COMMENTS HAVE BEEN ADDRESSED

Review Stop PW PUBLIC WORKS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 3 Status F Date 01-22-2014 Cont ID  
Sent By tward Date 01-22-2014 Time 21:21 Rev Time 0.00
Received By tward Date   Time   Sent To  
Notes
2014-01-22 21:24:181. THE TAMARIND AVENUE MAINTENANCE RIGHT-OF-WAY LINE IS
 NOT SHOWN CORRECTLY ON THE SITE PLAN. THE MAINTENANCE
 MAP IS RECORDED IN ROAD PLAT BOOK 11, PAGE 94 OF THE
 PBC CLERK'S OFFICE.
 2. ENGINEERING PLANS SHALL NOTE VERTICAL DATUM
 REFERENCE TO BE NGVD 1929.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 561-494-1120

Review Stop STORM STORMWATER
Rev No 2 Status F Date 11-06-2013 Cont ID  
Sent By tward Date 11-06-2013 Time 15:47 Rev Time 0.00
Received By tward Date   Time   Sent To  
Notes
2013-11-06 16:31:401. REMOVE REFERENCES TO RIVIERA BEACH IN CONSTRUCTION
 NOTES 3 AND 26 ON SHEET C-1 AND IN SIGNING AND PAVEMENT
 MARKING NOTE A ON SHEET C-6.
 2. IN COSNTRUCTION NOTE 63 ON SHEET C-1, THE OWNER OR
 CONTRACTOR AND NOT THE CITY WILL BE RESPONSIBLE FOR THE
 COSTS OF ALL DENSITY TESTS.
 3. LIST THE ELEVATION DATUM ON THE PAVING, GRADING AND
 DRAINAGE PLAN (SHEET C-3)
 4. THE CURB AT THE SOUTH DRIVEWAY SHOULD NOT EXTEND
 ACROSS THE SIDEWALK.
 5. CONSIDER RAISING THE EDGE OF PAVEMENT SPOT GRADE AT
 THE SOUTH FLUME INTO THE WEST DRY RETENTION AREA (DRA).
 THE CURRENT PROPOSED GRADE IS EQUAL TO THE CONTOUR
 INTERVAL OF THE DRA.
 6. NO CURBING SHOWN ALONG SIDE THE HANDICAP PARKING
 SPACES. WILL THE SIDEWALK BE FLUSH WITH THE PAVEMENT OR
 HAVE A THICKENED EDGE? PROVIDE A SIDEWALK DETAIL IF THE
 LATTER CONDITION.
 7. SHEET C-4 SHOWS DETAILS FOR CLOSED FLUME INLET. ANY
 REASON WHY AN OPEN FLUME CANNOT BE USED?
 8. SIGNING AND MARKING PLAN (SHEET C-6) DOESN'T MATCH
 THE SITE PLAN: (A) ACCESSIBLE PARKING SPACE DETAIL; (B)
 H.C. SIGN LOCATIONS; (C) H.C. SIGN FINE AMOUNT.
 9. SHOW AND LABEL THE TAMARIND AVE MAINTENANCE
 RIGHT-OF-WAY LINE ALONG WEST PROPERTY LINE ON SITE
 PLAN.
 10. VERIFY STANDARD PARK SPACE COUNT ON SITE PLAN.
 11. SHOW ON THE SITE PLAN THE DRA'S ALONG THE NORTH AND
 SOUTH PROPERTY LINES AS INDICATED ON SHEET C-3.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 561-494-1120
  
  
  
  

Review Stop STORM STORMWATER
Rev No 1 Status F Date 08-12-2013 Cont ID  
Sent By tward Date 08-12-2013 Time 14:34 Rev Time  
Received By tward Date   Time   Sent To  
Notes
2013-08-12 14:35:001. SHOW UTILITIES ON THE LANDSCAPE PLAN.
 2. ELEVATION DATUM SHOULD BE NGVD 1929.
 3. ENGINEERING PLANS NOT SIGNED AND SEALED.
 4. NO DRAINAGE STRUCTURES SHOWN ON PAVING, GRADING AND
 DRAINAGE PLAN.
 5. DETAIL SHEET SHOWS SIDEWALK FLUMES. WHERE ARE THESE
 PROPOSED TO BE CONSTRUCTED.
 6. STORMWATER QUALITY TREATMENT TO BE PROVIDED ONSITE
 PER SFWMD CRITERIA.
 7. SIGNED AND SEALED DRAINAGE CALCULATIONS TO BE
 SUBMITTED WITH THE ENGINEERING PERMIT APPLICATION.
 8. SIGNED AND SEALED ENGINEERING PLANS TO BE SUBMITTED
 WITH THE ENGINEERING PERMIT APPLICATION.
 9. STORM WATER POLLUTION PREVENTION PLAN TO BE
 SUBMITTED WITH THE ENGINEERING PERMIT APPLICATION.
 10. NOTE: ONLY 28 STANDARD PARKING SPACES SHOWN ON THE
 SITE PLAN.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 (561) 494-1120

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 08-12-2013 Cont ID  
Sent By vnoel Date 08-12-2013 Time 07:51 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2013-08-12 08:12:511. SITE/CIVIL PLANS WILL NEED TO BE SUBMITTED TO
 ENGINEERING FOR REVIEW.
 2. SURVEY IS OLDER THAN 1 YEAR.
 3. CITY DATUM IS NGVD-29. REVISE ELEVATIONS
 ACCORDINGLY.
 4. MORE INFORMATION IS NEEDED ON DRAINAGE. IS RETENTION
 PLANNED AROUND PARKING AREA?
 5. MAINTENANCE MAP FOR TAMARIND AVE. FILED IN ROAD PLAT
 BOOK 11, PG. 94.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date 08-12-2013 Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By bcollins Date 08-12-2013 Time 15:06 Sent To  
Notes
2013-08-12 15:05:54DETAILS FOR ACCESSIBLE PARKING SPACES DO NOT MATCH WHAT
 IS SHOWN ON PLAN.

Review Stop Z ZONING
Rev No 2 Status F Date 11-21-2013 Cont ID  
Sent By aaponte Date 11-21-2013 Time 10:28 Rev Time 0.00
Received By aaponte Date 11-14-2013 Time 15:59 Sent To  
Notes
2013-11-15 12:02:571. PARKING STRIPING DETAIL SHALL FOLLOW CITY STANDARDS
 (SEC 94-485).
 2. THE OUTDOOR SECURITY LIGHT AGREEMENT WITH FPL IS NOT
 SIGNED AND DATED BY FPL. PLEASE SUBMIT A COMPLETE COPY.
 3. PLEASE INDICATE THE LOCATION OF THE FPL POLES WHERE
 ADDITIONAL LIGHTING WILL BE INSTALLED, AND PROVIDE THE
 RELATED PHOTOMETRICS.
 4. PROPERTY SHALL BE UNIFIED WITH THE CHURCH PROPERTY.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE.

Review Stop Z ZONING
Rev No 1 Status F Date 08-13-2013 Cont ID  
Sent By aaponte Date 08-13-2013 Time 13:05 Rev Time 0.00
Received By aaponte Date 08-13-2013 Time 13:04 Sent To  
Notes
2013-08-13 14:25:571. A FIVE FOOT LANDSCAPE BUFFER SHALL BE PROVIDED ALONG
 TAMARIND AVENUE IN ADDITION TO THE TEN FEET REQUIRED
 SETBACK.
 2. PLEASE SHOW AUTO-TURN TO DEMONSTRATE THAT THE SPACE
 AT THE NW CORNER IS FUNCTIONAL.
 3. A DIRECT PEDESTRAIN ACCESS FROM TAMARIND AVENUE IS
 RECOMMENDED.
 4. STAFF RECOMMENDS TO CHANGE THE SILVER BUTTONWOOD FOR
 LIVE OAKS TO PROVIDE AN INCREASED SHADE FOR PEDESTRIANS
 ALONG TAMARIND.
 5. A UNITY OF TITLE WILL BE REQUIRED FOR THE THREE
 PROPERTIES.
 6. IRRIGATION PLAN WILL BE REQUIRED FOR ALL LANDSCAPE
 AREAS.
 7. LIGHTING SHALL BE PROVIDED FOR THE SURFACE PARKING
 ACCORDING TO CITY STANDARDS (SEC 86-294)
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.

  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved