Plan Review Details - Project Z13040023
Plan Review Stops For Project Z13040023
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 05-07-2013 Cont ID  
Sent By ajones Date 05-06-2013 Time 16:28 Rev Time 0.00
Received By lmartine Date 05-07-2013 Time 10:23 Sent To  
Notes
2013-05-07 10:28:15THE PRELIMINARY PLAN FOR THE ADMISSIONS COMPLEX LOOKS
 GOOD.
  
 NO PLANS WERE PROVIDED FOR THE PHASE 2 BUILDING.
  
  
 LUIS MARTINEZ
 561-805-6710

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By ktucker Date 05-07-2013 Time 11:03 Sent To  
Notes
2013-05-07 11:04:44 
 FIRST FLOOR
 * ENTRY INTO THE FACILITY WILL NEED ACCESS CONTROL
 AFTER ENTRY INTO THE LOBBY.
 * ALL EMPLOYEE AREAS WILL BE ACCESS CONTROLLED, SPECIAL
 CARE TO THE MEDICATION AREA
 * CAMERAS SHOULD BE PLACED IN THE MEDICATION AREAS,
 LOBBY, INTAKE AREAS, LIVING ROOMS, DINING ROOM,
 FOYER/ELEVATOR LOBBIES, INTAKE WAITING ROOM.
  
 SECOND FLOOR
 * CAMERAS FOR THE WAITING AREA, LIVING ROOM, NURSE
 STATION, MEDICATION AREA
 * ALL EMPLOYEE AREAS WILL BE ACCESS CONTROLLED, SPECIAL
 CARE TO THE MEDICATION AREA
  
 I WOULD LIKE TO SEE THE LIGHTING AND THE LANDSCAPE ON
 ONE SHEET TO ENSURE THERE IS NO OVERLAP
  
 CONDITIONS FOR APPROVAL
 PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE
 APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY
 AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST
 PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL.
 A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION
 TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE
 SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES
 FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT
 BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL,
 VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS,
 REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE
 SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF
 WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER
 MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE
 WORKING ENVIRONMENT.
 B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED
 THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT.
 NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A
 STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT
 DEVELOPMENT.
 C. PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY
 500 FEET AROUND THE PERIMETER OF THE SITE.
  
 LIGHTING
 A. LIGHT POLES 10 ? 15 FOOT HIGH FOR PEDESTRIAN-SCALE
 LIGHTING SHALL BE USED FOR ALL PEDESTRIAN WALKWAYS.
 B. PARKING LOT LIGHTING SHALL USE 20 -25 FOOT POLES.
 C. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF LIGHTING AND
 WALKWAYS.
 D. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR
 ABOVE OR NEAR ENTRYWAYS TO BUILDINGS FOR DUSK TO DAWN
 OPERATION SHALL BE PROVIDED.
 E. ENTRANCE SIGN LIGHTING SHALL BE PROVIDED. DIRECTORY
 SHOULD BE AT ALL ENTRANCES WITH LIGHTING
 F. BUILDING LIGHTING (NON-GLARE) SHALL BE AROUND
 PERIMETER ON ALL SIDE.
 NUMERICAL ADDRESS
 A. ILLUMINATION FOR NIGHTTIME VISIBILITY IS REQUIRED.
 ADDRESS SHOULD BE PLACED UNDER A LIGHT FIXTURE OR BE
 BACK LIT.
 B. BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS
 REQUIRED.
 C. ADDRESS NUMBERS ON SUITES/OFFICES WITHIN
 MULTI-TENANT BUILDINGS SHALL BE A MINIMUM OF 6 INCHES
 HIGH.
 D. BUILDING NUMBERS SHALL BE A MINIMUM OF 12 INCHES
 HIGH AND PLACED IN A CONSPICUOUS LOCATION AWAY FROM
 LANDSCAPING. MULTIPLE LOCATIONS MAY BE REQUIRED.
 NUMBERS OF CONTRASTING COLORS SHOULD BE USED.
 DOORS
 A. EXTERIOR DOORS SHALL ALL BE EQUIPPED WITH SECURITY
 HINGES AND SHALL BE REINFORCED WITH CASE HARDENED
 STRIKE PLATES. CASE HARDENED DEADBOLT LOCKS SHALL BE
 PROVIDED ON ALL EXTERIOR DOORS WITH A MINIMUM (1) INCH
 THROW OR MECHANICAL INTERLOCK.
 B. GLASS PERIMETER DOORS SHALL BE EQUIPPED WITH CASE
 HARDENED GUARD RINGS TO PROTECT THE MORTISE LOCK
 CYLINDER.
 C. REAR DOORS SHALL BE EQUIPPED WITH 180-DEGREE
 PEEPHOLE/ SECURITY VIEWER.
 DESIGN
 A. BUILDING ARCHITECTURE SHALL ALLOW FOR ENHANCED
 NATURAL SURVEILLANCE OF ALL PARKING LOTS AND PROVIDE A
 SENSE OF SECURITY TO PATRONS AND VISITORS.
 B. DRIVE-THRU LANES SHALL HAVE ONE WAY SIGNAGE STATING
 SAME.
 C. LANDSCAPING SHALL NOT OBSTRUCT VIEW FROM WINDOWS OR
 WALKWAYS.
 D. CROSSWALKS SHALL BE RAISED AND DELINEATED BY USING
 CONTRASTING PAVER BLOCKS AS OPPOSED TO SURFACE
 STRIPING.
 E. ALL BUILDINGS SHALL BE PRE-WIRED FOR CLOSED-CIRCUIT
 TELEVISION (CCTV) AND ALARM SYSTEMS.
 F. DUMPSTERS SHALL NOT ALLOW FOR EASY CONCEALMENT,
 CREATE BLIND SPOTS OR HIDING AREAS AND SHOULD BE ABLE
 TO BE LOCKED.
 G. SIGNS SHALL CLEARLY IDENTIFY PUBLIC ENTRANCES.
 H. LANDSCAPING SHALL BE MAINTAINED AT 3 FEET OR LESS.
 TREES SHALL BE INSTALLED SO AS NOT TO CONFLICT WITH THE
 LIGHTING SYSTEM. LOWER CANOPY LIMBS ON TREES SHALL BE
 MAINTAINED AT 8 FEET OR HIGHER.
 I. BIKE RACKS SHOULD BE AT THE FRONT OF THE BUILDING OR
 COMPLEX, NOT IN THE PARKING LOT FOR EASY SURVEILLANCE
 AND SAFETY.
  
  

Review Stop PW PUBLIC WORKS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 5 Status F Date 09-10-2014 Cont ID  
Sent By tward Date 09-10-2014 Time 12:40 Rev Time 0.00
Received By tward Date   Time   Sent To  
Notes
2014-09-10 12:46:471. PROPOSED PERIMETER GRADES SHOULD BE NO LOWER THAN
 THE PEAK STAGE OF20.56' NGVD FOR THE 25-YEAR 3-DAY
 DESIGN STORM. THERE IS A SPOT ELEVATION OF 20.25
 LOCATED SE OF STRUCTURE D-9.
  
 2. THE NORTH AND EAST PIPE CONNECTIONS TO STRUCTURE D-9
 WILL NOT FIT INTO THE STRUCTURE, GIVEN THE PIPE INVERT
 ELEVATIONS, PIPE SIZES AND GRATE ELEVATION.
  
 3. INCLUDE WEIR CONTROL STRUCTURES IN INLETS WHERE THE
 EXFILTRATION TRENCHES ARE NOT AT THE SAME ELEVATION ON
 EACH SIDE OF THE INLET. THE WEIR SHOULD BE LOCATED ON
 THE EXFILTRATION PIPE WITH THE HIGHER INVERT ELEVATION.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 561-494-1120
  

Review Stop STORM STORMWATER
Rev No 4 Status F Date 06-03-2014 Cont ID  
Sent By tward Date 06-03-2014 Time 10:21 Rev Time 0.00
Received By tward Date   Time   Sent To  
Notes
2014-06-03 11:14:291. RESPONSE TO ROUND 3 OF COMMENTS INDICATED DRAINAGE
 CALCULATIONS WERE ATTACHED. THESE CALCULATIONS WERE NOT
 FOUND IN THE 6/3/14 SUBMITTAL PACKAGE.
 2. CONSIDER RELOCATING THE EXFILTRATION TRENCHES OR
 RE-DESIGNING THE DETAIL. THE EXFILTRATION TRENCH NORTH
 OF THE BUILDING WILL BE 21+ FEET DEEP AT THE EAST END.
 THE EXFILTRATION TRENCH IN THE COURTYARD WILL BE 25+
 FEET DEEP (IF THE 35.00 SPOT GRADES SHOWN ON THE
 CONCEPTUAL DRAINAGE PLAN ARE CORRECT).
 3. ON THE ROOT BARRIER DETAIL ON LANDSCAPE PLAN SHEET
 LP.4, INCLUDE THE PLACEMENT OF ROOT BARRIER ADJACENT TO
 EXFILTRATION TRENCH IN ADDITION TO PUBLIC WATER OR
 PUBLIC SEWER MAINS. SHOW ROOT BARRIER FOR TREES IN
 CLOSE PROXIMITY TO EXFILTRATION TRENCHES IF THE ROOTS
 WILL MIGRATE INTO THE TRENCHES.
 4. NOTE DOUBLE TEXT SHOWN ON THE SHRUB PLANTING DETAIL
 ON SHEET LP.4.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 561-494-1120
  

Review Stop STORM STORMWATER
Rev No 3 Status F Date 02-27-2014 Cont ID  
Sent By tward Date 02-27-2014 Time 08:52 Rev Time 0.00
Received By tward Date   Time   Sent To  
Notes
2014-02-27 09:14:521. COORDINATE WITH PUBLIC UTILITY DEPARTMENT ON
 REQUIREMENTS FOR EASEMENT ON THE WATER MAIN. SHOW
 PROPOSED EASEMENT ON SITE PLANS, ENGINEERING PLANS AND
 LANDSCAPE PLANS.
 2. PHASE 1 IS TO INCLUDE CONSTRUCTION OF THE PERIMETER
 BERM AROUND THE SITE.
 3. SPOT GRADE (21.64) ON WEST PERIMETER BERM IS LOWER
 THAN THE SFWMD MINIMUM BERM ELEVATION CRITERIA OF
 21.82' NGVD.
 4. PROVIDE A CROSS SECTION OF THE EXFILTRATION TRENCH
 AND INDICATE HOW THE STORMWATER RUNOFF WATER LEVEL WILL
 BE CONTROLLED IN THE TRENCH.
 5. LABEL THE CONTOURS (ELEVATIONS) FOR THE SOUTHWEST
 RETENTION AREA.
 6. PREVIOUS COMMENTS REGARDING SUBMITTALS WITH THE
 ENGINEERING PERMIT APPLICATION AND BEFORE START OF
 CONSTRUCTION HAVE NOT BEEN ADDRESSED OR ACKNOWLEDGED.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 (561) 494-1120

Review Stop STORM STORMWATER
Rev No 2 Status F Date 07-24-2013 Cont ID  
Sent By tward Date 07-24-2013 Time 08:14 Rev Time 0.00
Received By tward Date   Time   Sent To  
Notes
2013-07-24 08:14:22NO ENGINEERING PLANS OR CALCULATIONS IN THE JUNE 19,
 2013 SUBMITTAL.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 (561) 494-1120

Review Stop STORM STORMWATER
Rev No 1 Status F Date 05-08-2013 Cont ID  
Sent By tward Date 05-08-2013 Time 11:56 Rev Time  
Received By tward Date   Time   Sent To  
Notes
2013-05-08 12:04:001. PROVIDE COPY OF SFWMD ERP OR NO-NOTICE PERMIT PRIOR
 TO START OF CONSTRUCTION.
 2. PROVIDE COPY OF NPDES NOI PERMIT PRIOR TO START OF
 CONSTRUCTION.
 3. PROVIDE DRAINAGE CALCULATIONS, INCLUDING LAND USE
 BREAKDOWN (PERVIOUS, IMPERVIOUS, BUILDING, ETC), WATER
 QUALITY TREATMENT, ETC., WITH THE CITY'S ENGINEERING
 PERMIT APPLICATION.
 4. PROVIDE SWPPP PLAN WITH THE CITY'S ENGINEERING
 PERMIT APPLICATION.
 5. WILL WATER MAIN HAVE MASTER METER OR WILL EASEMENT
 OVER THE WATER MAIN BE PROVIDED?
 6. COURTYARD DRAINAGE PIPE LOCATED UNDER BUILDING
 FOUNDATION INSTEAD OF RUNNING TO WEST UNDER THE GROUND
 LEVEL PARKING.
 7. ON CONCEPTUAL ENGINEERING PLAN, SHOW EXFILTRATION
 TRENCH OUTLINE FOR THE 55' (45') - 15" FRN DRN
 NORHTWEST OF THE BUILDING.
 8. PROVIDE CROSS SECTIONS OF RETENTION AREAS SHOWING
 SIDE SLOPES AND TOP/BOTTOM ELEVATIONS WITH THE
 ENGINEERING PLANS WHEN SUBMITTING FOR AN ENGINEERING
 PERMIT WITH THE CITY.
 9. TIE ROOF DRAINS INTO DRAINAGE SYSTEM OR DISCHARGE
 ONTO PERVIOUS AREAS.
 10. WHAT DRAINAGE AREA IS TRIBUTARY TO THE SMALLER
 RETENTION AREA?
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 (561) 494-1120
  

Review Stop SURVEY SURVEYING
Rev No 2 Status P Date 07-17-2013 Cont ID  
Sent By vnoel Date 07-17-2013 Time 09:42 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2013-07-17 09:43:24APPROVED WITH CONDITION OF PLAT RECORDATION PRIOR TO
 C.O.

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
2013-05-07 09:26:451. ENTIRE PROPERTY WILL NEED TO BE PLATTED AS A
 CONDITION OF FINAL SITE PLAN APPROVAL.
 2. PROPOSED LANDSCAPING SHOULD NOT CONFLICT WITH
 EXISTING OR PROPOSED UTILITIES.
 3. SEPARATE SUBMITTAL WILL NEED TO BE MADE FOR
 SITE/CIVIL AND PLAT TO ENGINEERING SERVICES.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 09-17-2014 Cont ID  
Sent By dkittred Date 09-17-2014 Time 13:55 Rev Time 0.00
Received By dkittred Date 08-28-2014 Time 13:54 Sent To  
Notes
2014-09-17 16:38:24PLANNING AND ZONING COMMENTS:
  
 9/17/14
  
 PASSED WITH CONDITIONS THAT CAN BE ADDRESSED AT TIME OF
 BUILDING PERMIT SUBMITTAL:
  
 1. BICYCLE PARKING PROVIDED ON THE PLANS NEEDS TO
 LOCATED NEAR A PRINCIPAL ENTRANCE OF A BUILDING IN A
 CONVENIENT LOCATION [ZLDR SEC. 94-485(Q)(2)(8) AND
 (10)]. AS A RESULT, ONE OF THE PROPOSED BICYLE RACKS
 SHALL BE LOCATED ON THE EAST SIDE OF THE BUILDING NEAR
 THE MAIN ENTRANCE. ADDITIONALLY, THE BICYCLE RACK
 DETAIL WILL NEED TO BE REVISED TO SHOW AN INVERTED 'U',
 POST AND CIRCLE, OR SIMILAR TYPE RACK. THE WAVE STYLE
 RACK IS NOT PERMITTED.
  
 2. A TREE ALTERATION PERMIT WILL BE REQUIRED THROUGH
 THE PLANNING DIVISION IF ANY TREES ON THE SITE WILL
 NEED TO BE REMOVED OR RELOCATED FOR THIS PROJECT.
 ISSUANCE OF THE TREE ALTERATION PERMIT WILL BE REQUIRED
 PRIOR TO ZONING APPROVAL OF ANY SITE WORK FOR THIS
 PROJECT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 06-10-2014 Cont ID  
Sent By dkittred Date 06-10-2014 Time 11:39 Rev Time 0.00
Received By dkittred Date 06-02-2014 Time 09:39 Sent To  
Notes
2014-06-10 11:39:20PLANNING AND ZONING COMMENTS:
  
 6/10/14 (BASED ON 5/30/14 SUBMITTAL COMMENTS HAVE BEEN
 REVISED TO WHAT IS LISTED BELOW)
  
 1. BICYCLE PARKING WILL NEED TO BE PROVIDED ON THE SITE
 PER ZLDR SEC. 94-485(Q). PLAN WILL NEED TO INCLUDE
 CALCULATION AND DETAIL WITH RACK STYLE AND SPACING.
 THIS COMMENT CAN BE ADDRESSED DURING SUBMITTAL OF THE
 BUILDING PERMIT FOR THIS PROJECT.
  
 2. A TREE ALTERATION PERMIT WILL BE REQUIRED THROUGH
 THE PLANNING DIVISION IF ANY TREES ON THE SITE WILL
 NEED TO BE REMOVED OR RELOCATED FOR THIS PROJECT.
 ISSUANCE OF THE TREE ALTERATION PERMIT WILL BE REQUIRED
 PRIOR TO ZONING APPROVAL OF ANY SITE WORK FOR THIS
 PROJECT.
  
 3. SITE PLAN SHEETS (SP.1 AND RP.1) OF THE SUBMITTAL
 FROM MAY 30, 2014 ARE NOT SIGNED AND SEALED. SOMEONE
 CAN COME TO THE PLANNING DIVISION TO SIGN AND SEAL THE
 SHEETS OR FOUR NEW SHEETS THAT ARE SIGNED AND SEALED
 CAN BE SUBMITTED.
  
 PLEASE NOTE WRITTEN RESPONSES TO REVIEW COMMENTS MADE
 BY DEPARTMENTS SHALL BE PROVIDED IN WRITTEN FORMAT WHEN
 RESUBMITTING AND ANY CHANGES TO THE PLANS SHALL BE
 CLOUDED OR OTHER SIMILAR NOTATION INDICATING WHERE
 CHANGES HAVE BEEN MADE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 02-27-2014 Cont ID  
Sent By dkittred Date 02-27-2014 Time 14:30 Rev Time 0.00
Received By dkittred Date 02-24-2014 Time 14:20 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 05-06-2013 Cont ID  
Sent By ajones Date 05-06-2013 Time 16:36 Rev Time 0.00
Received By ajones Date 05-06-2013 Time 16:27 Sent To  
Notes
2013-05-06 16:37:335-6-13
 GENERAL COMMENTS: WHEN RESUBMITTING:
 A. PROVIDE WRITTEN RESPONSES TO REVIEW COMMENTS MADE BY
 DEPARTMENTS IN A WRITTEN FORMAT WHEN RESUBMITTING.
 B. 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE
 PROVIDED, ALONG WITH ONE REDUCED COPY AND AN ELECTRONIC
 COPY OF ALL PLANS.
 C. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
 D. PLEASE NOT THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
 E. IN ORDER TO BE CONSIDERED FOR THE JUNE 18, 2013
 PLANNING BOARD MEETING, ALL PLANS MUST BE REVISED AND
 RESUBMITTED BY MAY 24 2013.
  
 SITE PLAN: A. MAXIMUM LOT COVERAGE BY A BUILDING IN A
 CSPD IS 50% THE SITE PLAN SHOWN 60%.
  B. THE FOLLOWING LETTERS ARE NEEDED PRIOR TO
 SCHEDULING BEFORE THE PLANNING BOARD:
  - UTILITY LETTERS FROM FPL, COMCAST AND FLORIDA
 PUBLIC UTILITIES
  - A TRAFFIC LETTER FROM PALM BEACH COUNTY
  C. VERIFY THE TOTAL NUMBER OF PARKING SPACES PROVIDED.
  D. THE PROPOSED CONNECTION TO ST. MARY?S PROPERTY WILL
 REQUIRE A MINOR AMENDMENT TO ST. MARY?S AND HILLCREST
 HANLEY CSPD?S.
  E. HOW DOES THE PARKING ALONG THE EAST SIDE OF THE
 REAR OF THE BUILDING WORK IN CONJUNCTION WITH THE
 COLUMNS FOR THE ROOFED STRUCTURE OVER A PORTION OF THE
 PARKING SPACES?
  
 LANDSCAPING: A. MOVE THE FENCE ALONG THE NORTH PROPERTY
 LINE TO THE BACK OF THE PROPERTY LINE.
  B. PROVIDE A TABLE ON THE LANDSCAPE PLAN SHOWING A
 BREAKDOWN OF SPECIES BE REQUIRED/PROVIDED, OPEN SPACE
 AND XERISCAPING REQUIREMENTS.
  
 ANGELLA VANN AICP
 561-822-1441
 [email protected]
  
  

  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved