Plan Review Details - Project Z12120014
Plan Review Stops For Project Z12120014
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 01-09-2013 Cont ID  
Sent By lmartine Date 01-09-2013 Time 10:35 Rev Time 0.00
Received By lmartine Date 01-09-2013 Time 10:35 Sent To  
Notes
2013-01-09 10:48:57BUILDING REVIEW COMMENTS
  
  
 : PALM BEACH COUNTY IMPACT FEES MAY APPLY.
  
 : PLEASE REVIEW TABLES 500 AND 600 FLORIDA BUILDING
 CODE 2010 FOR ANY ADJUSTMENTS TO THE EXISTING BUILDING
 TYPE.
  
 : THE PLANS PROVIDED ARE TOO PRELIMINARY FOR FURTHER
 CODE ANALYSIS.
  
  
  
  
 LUIS MARTINEZ
 561-805-6710

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 01-07-2013 Cont ID  
Sent By bmoree Date 01-07-2013 Time 11:23 Rev Time 0.00
Received By bmoree Date 01-07-2013 Time 11:19 Sent To  
Notes
2013-01-07 11:22:571. A SEPARATE SUBMITTAL OF STORMWATER IMPACT REQUIRED
 FOR ENGINEERING & PUBLIC WORKS. PLAN NEEDS TO DETAIL
 PERVIOUS / IMPERVIOUS CHANGES FROM PRE TO POST
 CONSTRUCTION.
  
 BRIAN R. MOREE, MPA, FCHP
 ENGINEERING CONSTRUCTION MANAGER
 CONSTRUCTION ADMINISTRATION
 ENGINEERING SERVICES & PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET
 FOURTH FLOOR
 WEST PALM BEACH, FLORIDA 33401
 OFFICE: 561-494-1098
 MOBILE: 561-644-7270
 EMAIL: [email protected]
 WEB: WWW.WPB.ORG/ENGINEERING
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 01-09-2013 Cont ID  
Sent By ddaniels Date 01-09-2013 Time 08:44 Rev Time 0.00
Received By ddaniels Date 01-09-2013 Time 08:43 Sent To  
Notes
2013-01-09 09:54:57 
 FIRE PLAN REVIEW: PLANS REVIEWED BY FIRE ***DENIED***
 PERMIT #Z12120014
 ADDRESS: MORSELIFE-MARILYN & STANLEY M. KATZ SENIOR
 CAMPUS
 4847 FRED GLADSTONE DRIVE
  
  
 1. SHOW SCOPE OF WORK ON PLANS.
  
 2. DESIGN SHALL CONFORM TO THE 2010 EDITION OF THE
 FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE FLORIDA
 EDITION OF NFPA 1 AND NFPA 101.
  
 3. ALL DEMOLITION WORK SHALL CONFORM TO THE
 REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION DEBRIS
 SHALL BE REMOVED FROM THE SITE DAILY.
  
 4. SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM AND/OR FIRE ALARM SYSTEM.
  
 5. PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY
 TYPES, OCCUPANT LOADS, FIRE RATED WALLS, EXIT SIGNS,
 EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON PATH OF
 TRAVEL ETC.
  
  
 DERRICK L. DANIELS, BATTALION CHIEF / FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 OFFICE OF THE FIRE MARSHAL
 (561) 804-4709
 [email protected]
  

Review Stop L LANDSCAPING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PARK PARKING
Rev No 1 Status F Date 01-09-2013 Cont ID  
Sent By ssamuels Date 01-09-2013 Time 10:11 Rev Time 0.00
Received By ssamuels Date 01-09-2013 Time 10:10 Sent To  
Notes
2013-01-09 10:15:07PLEASAE PROVIDE SITE DATA OF PARKING SPECIFICATION IN
 ACCORDANCE WITH THE CITY CODE.
  
 THE FOLLOWING:
 ADA - SIGN, SYMBOL , PARKING SPACE AND AISLE
 REGULAR PARKING SPACE
 DIRECTIONAL SIGN
  

Review Stop POLICE POLICE
Rev No 1 Status P Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
2013-01-09 11:17:36CONDITIONS FOR APPROVAL
 PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE
 APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY
 AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST
 PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL.
 A.AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION
 TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE
 SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES
 FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT
 BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL,
 VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS,
 REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE
 SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF
 WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER
 MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE
 WORKING ENVIRONMENT.
 B.THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED
 THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT.
 NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A
 STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT
 DEVELOPMENT.
 C.PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY
 500 FEET AROUND THE PERIMETER OF THE SITE.
  
  
  
 A. EXTERIOR DOORS SHALL ALL BE EQUIPPED WITH SECURITY
 HINGES AND SHALL BE REINFORCED WITH CASE HARDENED
 STRIKE PLATES. CASE HARDENED DEADBOLT LOCKS SHALL BE
 PROVIDED ON ALL EXTERIOR DOORS WITH A MINIMUM (1) INCH
 THROW OR MECHANICAL INTERLOCK.
 B. GLASS PERIMETER DOORS SHALL BE EQUIPPED WITH CASE
 HARDENED GUARD RINGS TO PROTECT THE MORTISE LOCK
 CYLINDER.
 C. REAR DOORS SHALL BE EQUIPPED WITH 180-DEGREE
 PEEPHOLE/ SECURITY VIEWER.
 D. ALL BUILDINGS SHALL BE PRE-WIRED FOR CLOSED-CIRCUIT
 TELEVISION (CCTV) AND ALARM SYSTEMS
 E. SIGNS SHALL CLEARLY IDENTIFY PUBLIC ENTRANCES.
  
  

Review Stop PW PUBLIC WORKS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 1 Status   Date 01-04-2013 Cont ID  
Sent By tward Date 01-04-2013 Time 13:18 Rev Time  
Received By tward Date   Time   Sent To  
Notes
***NONE***

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 01-09-2013 Cont ID  
Sent By vnoel Date 01-09-2013 Time 12:30 Rev Time  
Received By vnoel Date   Time   Sent To  
Notes
2013-01-07 08:32:241. COPY OF PLAT INSUFFICIENT. SPECIFIC PURPOSE SURVEY
 IN AREA OF PROPOSED ADDITION WILL BE REQUIRED TO
 DETERMINE IMPACT AND SETBACKS.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status P Date   Cont ID  
Sent By   Date 01-04-2013 Time   Rev Time 0.00
Received By bcollins Date 01-04-2013 Time 08:20 Sent To  
Notes
2013-01-04 08:21:26NO COMMENTS

Review Stop Z ZONING
Rev No 1 Status F Date 01-08-2013 Cont ID  
Sent By eschneid Date 01-08-2013 Time 19:02 Rev Time 1.00
Received By eschneid Date 01-08-2013 Time 19:02 Sent To  
Notes
2013-01-08 19:02:21CASE NO. 1248S
 MORSELIFE PACE EXPANSION FORMAL SITE PLAN
 4847 FRED GLADSTONE DR.
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX
 (6) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS MAY RESULT IN ADDITIONAL COMMENTS.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS
 FROM THE DATE OF THE PPRC MEETING (MARCH 9, 2013), THE
 CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER ACTION
 SHALL REQUIRE A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($300).
  
 1) THE 16 NEW PARKING SPACES ARE NOT SHOWN CORRECTLY ON
 THE SITE & LANDSCAPE PLAN. THE DIMENSION LINE, THE
 INTERIOR ISLAND, AND THE PARKING SPACE DIVIDER LINES
 SHALL BE EXTENDED TO THE DASHED LINE.
  
 2) A D-CURB IS REQUIRED ON THE TWO END SPACES OF THE
 NEW 16 SPACE PARKING BAY TO PROTECT THE LANDSCAPE.
  
 3) CURBING IS REQUIRED TO PROTECT THE LANDSCAPE FOR THE
 TEMPORARY VAN PARKING AREA.
  
 4) THE SCALE AT THE TEMPORARY VAN PARKING SEEMS TO NOT
 MATCH THE DIMENSION DEPTH. HOW ARE THE REGULAR PARKING
 SPACES IN LINE WITH THE NEW 19 FOOT VAN SPACES?
  
 5) AN UPDATED TREE ALTERATION PERMIT IS REQUIRED.
  
 6) THE MASTER PLAN PARKING TABLE SHALL REFLECT THAT THE
 MORSE GERIATRIC CENTER BUILDING REQUIRES 30 PARKING
 SPACES (BASED ON THE 9,000 SQ. FT. OF OFFICE AREA) NOT
 23 AS SHOWN. THIS IS A COMMENT THAT WAS NOT ADDRESSED
 CORRECTLY FROM THE HOME HEALTH CARE APPLICATION.
  
 7) THE ARCHITECTURAL PLAN AND THE SITE/LANDSCAPE PLAN
 SHOW DIFFERING CONDITIONS IN THE PORTE COCHERE AND
 ENTRY DRIVE ISLAND.
  
 8) IS THE ENTRY PORTE COCHERE BEING MODIFIED? IF SO
 PLEASE PROVIDE ELEVATION DRAWINGS TO VERIFY THAT THE
 NEW DESIGN COMPLIES WITH THE HEIGHT REQUIREMENTS FOR
 EMERGENCY VEHICLES.
  