Plan Review Details - Project Z12100007
Plan Review Stops For Project Z12100007
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 11-14-2012 Cont ID  
Sent By lmartine Date 11-14-2012 Time 10:22 Rev Time 0.00
Received By lmartine Date 11-14-2012 Time 10:22 Sent To  
Notes
2012-11-14 10:51:19BUILDING REVIEW COMMENTS
  
  
 PRELIMINARY PLANS LOOK GOOD FOR NOW.
  
 A THRESHOLD INSPECTOR WILL BE REQUIRE FOR THIS PROJECT.
  
  
  
 LUIS MARTINEZ
 561-805-6710
  
  
  
  
2012-11-13 15:59:42I SEE THE LIGHTING AROUND THE BUILDINGS, WHAT LIGHTING
 WILL IN BETWEEN THE BUILDINGS?
 ACCESS CONTROL SHOULD BE USED TO THE CLUBHOUSE AND THE
 FITNESS BLDG
 WILL THERE BE A PLAYGROUND? POOL? IF SO I WILL WANT TO
 SEE THE PLANS FOR THAT
 MAIL BOX AREA?
 WILL THE ENTRY/EXIT GATE HAVE CAMERA COVERAGE?
 BIKE RACKS?
 CONDITIONS FOR APPROVAL
 PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE
 APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY
 AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST
 PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL.
 A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION
 TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE
 SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES
 FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT
 BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL,
 VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS,
 REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE
 SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF
 WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER
 MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE
 WORKING ENVIRONMENT.
 B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED
 THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT.
 NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A
 STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT
 DEVELOPMENT.
 C. PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY
 500 FEET AROUND THE PERIMETER OF THE SITE.
 LIGHTING
 A. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS,
 BUILDING ADDRESS NUMBERS, LIGHTING AND WALKWAYS.
 B. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR
 ABOVE OR NEAR ENTRYWAYS TO RESIDENCES PROVIDE FOR DUSK
 TO DAWN OPERATION.
 C. ENTRANCE SIGN LIGHTING SHALL BE PROVIDED. DIRECTORY
 SHOULD BE AT ALL ENTRANCES WITH LIGHTING.
 D. BUILDING LIGHTING (NON GLARE) SHALL BE AROUND
 PERIMETER ON ALL SIDES.
 NUMERICAL ADDRESS
 A. ILLUMINATION FOR NIGHTTIME VISIBILITY IS REQUIRED.
 ADDRESS SHOULD BE PLACED UNDER A LIGHT FIXTURE OR BE
 BACK LIT.
 B. ADDRESS NUMERALS SHALL BE OF A CONTRASTING COLOR TO
 THE BUILDING COLOR
 C. BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS
 REQUIRED.
 D. ADDRESS NUMBERS ON DOORS OF MULTI-UNITS AND SINGLE
 FAMILY HOMES NEED TO BE A MINIMUM OF 6 INCHES HIGH.
 E. BUILDING NUMBERS FOR MULTI-UNIT BUILDINGS SHALL BE A
 MINIMUM OF 12 INCHES HIGH AND PLACED IN A CONSPICUOUS
 LOCATION ON ALL SIDES WITH PUBLIC ACCESS, AWAY FROM
 LANDSCAPING. NUMBERS SHOULD BE OF A CONTRASTING
 BACKGROUND.
 DOORS
 A. DOOR LEADING INTO A RESIDENTIAL UNIT, INCLUDING
 INTERIOR GARAGE SHALL BE SOLID CORE.
 B. EXTERIOR DOORS SHALL BE EQUIPPED WITH A 180-DEGREE
 PEEPHOLE AND NON-REMOVABLE SECURITY HINGES.
 LOCKS
 A. ANTI-LIFTING AUXILIARY LOCKS SHALL BE INSTALLED ON
 SLIDING DOORS AND WINDOWS.
 B. ALL DOORS SHALL BE EQUIPPED WITH SINGLE CYLINDER
 DEAD BOLT LOCK WITH A MINIMUM THROW OF ONE INCH AND AN
 EMBEDMENT OF NOT LESS 5/8 INCH INTO THE HOLDING DEVICE.
 PICK PLATES SHOULD ALSO BE PLACED ALL EXTERIOR DOORS.
 MISCELLANEOUS
 A. STAIRWAYS (TO INCLUDE RISERS/BANISTERS)
 B. SALES CENTER, CLUBHOUSE AND RECREATIONAL FACILITIES
 SHALL BE PRE-WIRED TO ALARM CENTER.
 C. RECREATION BUILDING AND POOL ACCESS SHALL BE
 RESTRICTED, BY KEY, KEY FOB, OR CARD ACCESS
 D. BICYCLE SPACES SHALL BE LOCATED IN CLOSE PROXIMITY
 TO THE FRONT OF BUILDINGS AND NOT IN PARKING LOTS.
 E. MAILBOX LOCATIONS SHALL BE IN A WELL LIT, HIGH
 TRAFFIC LOCATION.
  
  

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 11-07-2012 Cont ID  
Sent By bmoree Date 11-07-2012 Time 09:47 Rev Time 0.00
Received By bmoree Date 11-07-2012 Time 09:47 Sent To  
Notes
2012-12-13 14:15:001. PLEASE SEE COMMENTS FROM 11/7/12.
 2. SEPARATE APPLICATION FOR ENGINEERING AND PUBLIC
 WORKS PERMIT REQUIRED.
 3. WATER DISTRIBUTION MAIN AND FIRELINE SHALL BE MASTER
 METERED AND PRIVATELY OWNED.
 4. DEVELOPER SHALL ASSUME OWNERSHIP AND MAINTENANCE OF
 THE EXISTING SANITARY SEWER MAIN.
 5. STORMWATER SYSTEM MUST BE DESIGNED FOR CONTAINMENT.
 (I.E.CONTROL STRUCTURE, DETENTION POND, EXFILTRATION
 TRENCH, ETC.)
  
 BRIAN R. MOREE, MPA, FCHP
 ENGINEERING CONSTRUCTION MANAGER
 CONSTRUCTION ADMINISTRATION
 ENGINEERING SERVICES & PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET
 FOURTH FLOOR
 WEST PALM BEACH, FLORIDA 33401
 OFFICE: 561-494-1098
 MOBILE: 561-644-7270
 EMAIL: [email protected]
 WEB: WWW.WPB.ORG/ENGINEERING
  
2012-11-07 09:47:371. SEPARATE APPLICATION FOR ENGINEERING & PUBLIC WORKS
 PERMIT REQUIRED.
 2. SITE CIVIL DRAWINGS ARE REQUIRED FOR COMPREHENSIVE
 INFRASTRUCTURE COMMENTS.
 3. AN ENVIRONMENTAL RESOURCE PERMIT FOR SFWMD WILL BE
 REQUIRED.
 4. AN PHASE I ENVIRONMENTAL SITE ASSESSMENT REPORT IS
 REQUIRED IN CONJUNCTION WITH FORMAL SITE DEVELOPMENT
 CIVIL INFRASTRUCTURE REVIEW.
 5. IN CONSIDERATION OF THE PREVIOUS USE OF THE SITE,
 THE CITY MAY REQUIRE ADDITIONAL ENVIRONMENTAL SITE
 ASSESSMENT AND CONTROL, WHICH MAY INCLUDE, BUT NOT BE
 LIMITED TO, ENVIRONMENT SAMPLING AND TESTING,
 DEWATERING CONTROL, CONSTRUCTION STORMAWATER CONVEYANCE
 MANAGEMENT, PARTICULATE ABATEMENT, AND ENVIRONMENTAL
 HAZARD ABATEMENT.
 6. STORMWATER POLLUTION PREVENTION PLAN (SWPPP) AND
 STORMWATER MANAGEMENT PLAN ARE REQUIRED.
 7. A SANITARY SEWER SYSTEM CAPACITY ENGINEERING
 EVALUATION WILL BE REQUIRED IN CONJUNCTION WITH FORMAL
 SITE DEVELOPMENT CIVIL INFRASTRUCTURE REVIEW.
 8. A WATER DISTRIBUTION SYS EVALUATION WILL BE REQUIRED
 IN CONJUNCTION WITH FORMAL SITE DEVELOPMENT CIVIL
 INFRASTRUCTURE REVIEW.
 9. UTILITY SYSTEM INFRASTRUCTURE IMPROVEMENTS AND/OR
 EXPANSION MAY BE REQUIRED TO SUPPORT THE PROPOSED
 DEVELOPMENT. THIS MAY INCLUDE, BUT IS NOT LIMITED TO,
 WATER DISTRIBUTION SYSTEM IMPROVEMENTS, SANITARY SEWER
 SYSTEM IMPROVEMENTS, AND STORMWATER CONVENIENCE SYSTEM
 IMPROVEMENTS.
 10. HIGHLY RECOMMEND CHANGING SITE LIGHTING FROM HPS TO
 LED.
  
 BRIAN R. MOREE, MPA, FCHP
 ENGINEERING CONSTRUCTION MANAGER
 CONSTRUCTION ADMINISTRATION
 ENGINEERING SERVICES & PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET
 FOURTH FLOOR
 WEST PALM BEACH, FLORIDA 33401
 OFFICE: 561-494-1098
 MOBILE: 561-644-7270
 EMAIL: [email protected]
 WEB: WWW.WPB.ORG/ENGINEERING
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By ddaniels Date 11-14-2012 Time 09:59 Sent To  
Notes
2012-11-14 10:00:1911/14/2012 PLANS REVIEWED BY FIRE ****DENIED****
  
 1. SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM AND/OR FIRE ALARM SYSTEM.
 2. SEPARATE PLANS AND PERMITS REQUIRED FOR ANY SECURITY
 GATES AND FENCES.
  
  
 DERRICK L. DANIELS, BATTALION CHIEF
 WEST PALM BEACH FIRE RESCUE
 OFFICE OF THE FIRE MARSHAL
 (561) 804-4709
  

Review Stop L LANDSCAPING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date 12-11-2012 Time   Sent To  
Notes
2012-11-08 14:22:15CONCERNED WITH THE USE OF THE LIVE OAKS IN THE NARROW
 PARKING SPACE BULB OUTS.

Review Stop PARK PARKING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status F Date 11-13-2012 Cont ID  
Sent By   Date 11-13-2012 Time   Rev Time  
Received By   Date 11-13-2012 Time   Sent To  
Notes
***NONE***

Review Stop PW PUBLIC WORKS
Rev No 1 Status F Date 11-07-2012 Cont ID  
Sent By bmoree Date 11-07-2012 Time 09:50 Rev Time 0.00
Received By bmoree Date 11-07-2012 Time 09:48 Sent To  
Notes
2012-11-07 09:50:111. SEPARATE APPLICATION FOR ENGINEERING & PUBLIC WORKS
 PERMIT REQUIRED.
 2. SITE CIVIL DRAWINGS ARE REQUIRED FOR COMPREHENSIVE
 INFRASTRUCTURE COMMENTS.
 3. AN ENVIRONMENTAL RESOURCE PERMIT FOR SFWMD WILL BE
 REQUIRED.
 4. AN PHASE I ENVIRONMENTAL SITE ASSESSMENT REPORT IS
 REQUIRED IN CONJUNCTION WITH FORMAL SITE DEVELOPMENT
 CIVIL INFRASTRUCTURE REVIEW.
 5. IN CONSIDERATION OF THE PREVIOUS USE OF THE SITE,
 THE CITY MAY REQUIRE ADDITIONAL ENVIRONMENTAL SITE
 ASSESSMENT AND CONTROL, WHICH MAY INCLUDE, BUT NOT BE
 LIMITED TO, ENVIRONMENT SAMPLING AND TESTING,
 DEWATERING CONTROL, CONSTRUCTION STORMAWATER CONVEYANCE
 MANAGEMENT, PARTICULATE ABATEMENT, AND ENVIRONMENTAL
 HAZARD ABATEMENT.
 6. STORMWATER POLLUTION PREVENTION PLAN (SWPPP) AND
 STORMWATER MANAGEMENT PLAN ARE REQUIRED.
 7. A SANITARY SEWER SYSTEM CAPACITY ENGINEERING
 EVALUATION WILL BE REQUIRED IN CONJUNCTION WITH FORMAL
 SITE DEVELOPMENT CIVIL INFRASTRUCTURE REVIEW.
 8. A WATER DISTRIBUTION SYS EVALUATION WILL BE REQUIRED
 IN CONJUNCTION WITH FORMAL SITE DEVELOPMENT CIVIL
 INFRASTRUCTURE REVIEW.
 9. UTILITY SYSTEM INFRASTRUCTURE IMPROVEMENTS AND/OR
 EXPANSION MAY BE REQUIRED TO SUPPORT THE PROPOSED
 DEVELOPMENT. THIS MAY INCLUDE, BUT IS NOT LIMITED TO,
 WATER DISTRIBUTION SYSTEM IMPROVEMENTS, SANITARY SEWER
 SYSTEM IMPROVEMENTS, AND STORMWATER CONVENIENCE SYSTEM
 IMPROVEMENTS.
 10. HIGHLY RECOMMEND CHANGING SITE LIGHTING FROM HPS TO
 LED.
 11. SOLID WASTE COLLECTION DUMPSTER AND COLLECTION
 ROUTE INFORMATION REQUIRED.
  
 BRIAN R. MOREE, MPA, FCHP
 ENGINEERING CONSTRUCTION MANAGER
 CONSTRUCTION ADMINISTRATION
 ENGINEERING SERVICES & PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET
 FOURTH FLOOR
 WEST PALM BEACH, FLORIDA 33401
 OFFICE: 561-494-1098
 MOBILE: 561-644-7270
 EMAIL: [email protected]
 WEB: WWW.WPB.ORG/ENGINEERING
  

Review Stop STORM STORMWATER
Rev No 1 Status F Date 11-11-2012 Cont ID  
Sent By tward Date 11-11-2012 Time 16:23 Rev Time  
Received By tward Date   Time   Sent To  
Notes
2012-11-11 16:22:501. SFWMD ERP PERMIT REQUIRED BEFORE START OF
 CONSTRUCTION.
 2. STORMWATER POLLUTION PREVENTION PLAN TO BE SUBMITTED
 WITH THE ENGINEERING PERMIT APPLICATION.
 3. NPDES CONSTRUCTION PERMIT REQUIRED BEFORE START OF
 CONSTRUCTION.
 4. SHOW AND LABEL PROPOSED UTILITIES AND EXISTING
 UTILITIES THAT ARE TO REMAIN AS WELL AS ALL EASEMENTS
 ON THE LANDSCAPE PLANS.
 5 COORDINATE ENGINEERING SITE PLAN, LANDSCAPE PLAN TO
 MINIMIZE CONFLICTS BETWEEN UTILITIES, TREES AND LIGHT
 POLES. ROOT BARRIER RECOMMENDED WHEN HORIZONTAL
 SEPARATION BETWEEN UTILITIES AND TREES ARE LESS THAN
 FIVE FEET.
 6. WILL THE EXISTING SANITARY SEWER SYSTEM CROSSING THE
 SITE REMAIN? VERIFY TREES ARE ALLOWED WITHIN THE
 UTILITY EASEMENT OVER THE SANITARY SYSTEM AND WITHIN
 THE UTILITY EASEMENT ALONG EXECUTIVE CENTER DRIVE.
 7. HOW WILL THE STORMWATER RUNOFF FROM THE WIDENED
 LUMBERTON DRIVE BE MANAGED?
 8. VERIFY THE EXISTING INLET ON LUMBERTON DRIVE IS
 SUFFICIENT FOR THE ROAD.
 9. VERIFY THE EXISTING OUTFALL PIPE IS SUFFICENT FOR
 THIS PROJECT AND LUMBERTON DRIVE.
  
 TRACY L. WARD, P.E.
 SENIOR STORM WATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 561-494-1120
  

Review Stop SURVEY SURVEYING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
2012-11-08 10:33:311. UTILITY EASEMENTS NEED TO BE GRANTED FOR EXISTING
 SANITARY AND LIFT STATION.
 2. SHOW PROPOSED EASEMENTS ON ALL PLANS.
 3. NO PRELIMINARY WATER AND SEWER PLAN PROVIDED.
 4. HOW IS GARBAGE COLLECTION BEING HANDLED?

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By bcollins Date 11-09-2012 Time 15:30 Sent To  
Notes
2012-11-09 15:37:15NEED TRAFFIC STUDY TO DETERMINE THE IMPACTS AT THE
 INTERSECTION OF EXECUTIVE CENTER DRIVE AND LAMBERTON
 DRIVE. THE STUDY SHALL ALSO CONSIDER LEFT TURN
 MOVEMENTS INTO CITYSIDE II (CALIMESA ROAD). APPLICANT
 SHALL SHOW ANY PROPOSED STRIPING CHANGES AT THE
 INTERSECTION TO ACCOMODATE SITE TRAFFIC. ONLY 513 OF
 THE REQUIRED 564 SPACES ARE ON SITE. WHERE WILL THE
 "OVERFLOW" VEHICLES PARK? WHAT IS THE BASIS FOR A
 PROPOSED PARKING WAIVER?

Review Stop Z ZONING
Rev No 1 Status F Date 11-13-2012 Cont ID  
Sent By ajones Date 11-13-2012 Time 17:25 Rev Time 0.00
Received By ajones Date 11-13-2012 Time 15:33 Sent To  
Notes
2012-11-13 17:26:1011/13/12 CITY OF WEST PALM BEACH
  PLANNING DIVISION
  
  
  PLANS AND PLATS REVIEW COMMITTEE
  NOVEMBER 14, 2012
  
 GENERAL COMMENTS:
  
 1. WHEN RESUBMITTING:
 A. PROVIDE WRITTEN RESPONSES TO REVIEW COMMENTS MADE BY
 DEPARTMENTS IN A WRITTEN FORMAT WHEN RESUBMITTING.
 B. 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE
 PROVIDED, ALONG WITH ONE 91) REDUCED COPY AND AN
 ELECTRONIC COPY OF ALL PLANS.
 C. IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE
 ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE
 CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL
 REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION.
 D. PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE.
 E. IN ORDER TO BE CONSIDERED FOR THE DECEMBER 18, 2012,
 PLANNING BOARD MEETING, ALL PLANS MUST BE REVISED AND
 RESUBMITTED BY NOVEMBER 26, 2012.
  
 SITE PLAN:
  
 1. PARKING COUNTY DOES NOT MATCH NUMBER SHOWN UNDER
 PARKING REQUIRED ON THE SITE PLAN. PLEASE VERIFY
 NUMBERS.
 2. SECTION 94-443 (3)(B) REQUIRES ONE (1) INTERIOR
 LANDSCAPE ISLAND SHALL BE PROVIDED FOR EVERY 10 PARKING
 SPACES. THERE ARE TWO (2) AREAS WHERE THE PARKING
 SPACES EXCEED 10 SPACES.
 3. ALL PROPOSED ON STREET PARKING SHALL BE SHOWN ON THE
 SITE PLAN.
 4. DEAD END DRIVE AISLES REQUIRE AT LEAST ONE (1)
 PARKING SPACE STRIPED OUT TO ALLOW FOR TURNAROUND
 AREAS. APPLICANT MUST PROVIDE THIS SPACE FOR THE DEAD
 END DRIVE AISLES.
 5. SECTION 94-302 (B)(1) REQUIRES THAT FENCES/WALLS
 CANNOT EXCEED FOUR (4) FEET IN HEIGHT WITHIN THE FRONT
 SETBACK. THE ZLDRS DEFINES THE FRONT AS THE NARROWEST
 WIDTH FOR CORNER LOTS. THEREFORE, CONGRESS AVENUE IS
 CONSIDERED THE FRONT. A WAIVER FROM THE FENCE HEIGHT
 ALONG CONGRESS AVENUE WILL NEED TO BE REQUESTED.
 6. IF LAMBERTON DRIVE IS A PLATTED RIGHT-OF-WAY THAN
 THE FRONT OF THE PROPERTY WILL BE CONSIDERED LAMBERTON
 DRIVE. IF NOT THE FOLLOWING WILL BE CONSIDERED THE
 PROPERTY FRONTAGES FOR SETBACK PURPOSES. ADDITIONAL
 WAIVERS MAY BE NEEDED.
 - CONGRESS AVENUE FRONT
 - EXECUTIVE CENTER DRIVE CORNER SIDE
 - LAMBERTON DRIVE/PROPERTY ADJACENT TO THE HOTEL REAR
 - PROPERTY LINE ADJACENT TO I-95 SIDE
 7. PROVIDE HEIGHT ELEVATION SHOWING THE MEASUREMENTS
 FROM SLAB TO THE MEAN HEIGHT LEVEL BETWEEN THE EAVES
 AND RIDGE.
  
 LANDSCAPE PLAN
  
 1. SECTION 94-442 (4)(G) OF THE ZLDRS REQUIRE THAT ALL
 NEW DEVELOPMENT SHOW ON THEIR PLANS THAT THEY MEET THE
 XERISCAPE REQUIREMENTS.
 2. A TREE ALTERATION PERMIT WILL BE REQUIRED TO REMOVE
 ANY TREES.
 3. NO WALLS WILL BE REQUIRED FOR THE VEHICULAR USE
 AREAS ADJACENT TO THE PROPERTY LINE.
 4. FOR ALL HARDWOOD SHADE TREES PLANTED IN TERMINAL
 ISLANDS ROOT BARRIERS SHALL BE PROVIDED.
  
 DESIGN ISSUES:
 1. AS DISCUSSED IN PRE APPLICATION MEETING, THE
 APPLICANT SHALL PROVIDE ILLUSTRATIONS AND JUSTIFICATION
 AS TO HOW THE UNITS FRONTING ON EXECUTIVE CENTER DRIVE
 CREATE A PEDESTRIAN ENVIRONMENT AND FIT INTO THE URBAN
 ENVIRONMENT THAT THE CITY HAS ATTEMPTED TO CREATE ALONG
 THIS SECTION OF EXECUTIVE CENTER DRIVE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME.
  
 ANGELLA VANN, AICP, PLANNING AND ZONING ADMINISTRATOR
 561-822-1441
 [email protected]
  
  