Plan Review Details - Project Z12060018
Plan Review Stops For Project Z12060018
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 07-11-2012 Cont ID  
Sent By lmartine Date 07-11-2012 Time 09:45 Rev Time 0.00
Received By lmartine Date 07-11-2012 Time 09:45 Sent To  
Notes
2012-07-11 10:02:33BUILDING REVIEW COMMENTS
  
  
  
 AN ELEVATION CERTIFICATE WILL BE REQUIRED FOR FLOOD
 ZONE A-8.
  
 APPROVED FLORIDA MANUFACTURED BUILDING PLANS WILL BE
 REQUIRED FOR PERMITTING.
  
 PROVIDE COMPLETE DRAWINGS FOR THE ACCESSIBLE RAMP, SEE
 405 FL. ACCESSIBILITY CODE 2010.
  
  
  
 LUIS MARTINEZ
 561-805-6710

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 07-10-2012 Cont ID  
Sent By bmoree Date 07-10-2012 Time 09:02 Rev Time 0.00
Received By bmoree Date 07-10-2012 Time 08:40 Sent To  
Notes
2012-07-10 09:01:145715 CORPORATE WAY
  
 1. PROVIDE DUMPSTER LOCATION REVISION. PROPOSED TRAILER
 LOCATION WILL CONFLICT WITH EXISTING DUMPSTER
 COLLECTION.
 2. SITE CIVIL DRAWINGS REQUIRED FOR WATER AND SANITARY
 CONNECTIONS TO PROPSED TRAILER.
 3. STORMWATER CALCULATIONS NEEDED FOR PROPSED PERVIOUS
 / IMPERVIOUS SITE CONDITION CHANGES.
  
 BRIAN R. MOREE, MPA, FCHP
 ENGINEERING CONSTRUCTION MANAGER
 CONSTRUCTION ADMINISTRATION
 ENGINEERING SERVICES & PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET
 FOURTH FLOOR
 WEST PALM BEACH, FLORIDA 33401
 OFFICE: 561-494-1098
 MOBILE: 561-644-7270
 EMAIL: [email protected]
 WEB: WWW.WPB.ORG/ENGINEERING
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 07-06-2012 Cont ID  
Sent By ddaniels Date 07-06-2012 Time 18:17 Rev Time 0.00
Received By ddaniels Date 07-06-2012 Time 18:17 Sent To  
Notes
2012-07-06 18:21:567/6/2012 PLANS REVIEWED BY FIRE ***DENIED***
  
  
 1. NOT ENOUGH INFORMATION FOR FIRE REVIEW.
  
 2. DESIGN SHALL CONFORM TO THE 2010 EDITION OF THE
 FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE FLORIDA
 EDITION OF NFPA 1 AND NFPA 101.
  
 DERRICK L. DANIELS, BATTALION CHIEF
 WEST PALM BEACH FIRE RESCUE
 OFFICE OF THE FIRE MARSHAL
 (561) 805-6733
  

Review Stop PARK PARKING
Rev No 1 Status F Date 07-07-2012 Cont ID  
Sent By ssamuels Date 07-07-2012 Time 18:34 Rev Time 0.00
Received By ssamuels Date 07-07-2012 Time 18:33 Sent To  
Notes
2012-07-07 18:37:48PARKING:
 PROVIDE DETAIL DATA SHOWING ALL PARKING SPECIFICATION
 INCLUDED BICYCLE RACK AND SIGNS.
 24' DRIVE AISLES DOES NOT LOOK CONSITENCE WITH PARKING
 SPACES AND ADA AISLES.
  
 SEAN SAMUELS CPP
 PARKING FACILITY SUPERVISOR
 PHONE: 561.822.1507
 E-MAIL SSAMUELS@WPB
  

Review Stop POLICE POLICE
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2012-07-05 10:24:44 NOT ENOUGH INFORMATION ON THE TRAILER, BUT KEEP IN
 MIND THE FOLLOWING:
  
 LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS,
 BUILDING ADDRESS NUMBERS, LIGHTING AND WALKWAYS.
  
 TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR
 ABOVE OR NEAR ENTRYWAYS TO BUILDINGS FOR DUSK TO DAWN
 OPERATION SHALL BE PROVIDED.
  
 BUILDING LIGHTING (NON-GLARE) SHALL BE AROUND PERIMETER
 ON ALL SIDE.
  
 EXTERIOR DOORS SHALL ALL BE EQUIPPED WITH SECURITY
 HINGES AND SHALL BE REINFORCED WITH CASE HARDENED
 STRIKE PLATES. CASE HARDENED DEADBOLT LOCKS SHALL BE
 PROVIDED ON ALL EXTERIOR DOORS WITH A MINIMUM (1) INCH
 THROW OR MECHANICAL INTERLOCK.
  
 IF ANY GLASS PERIMETER DOORS, IT SHALL BE EQUIPPED WITH
 CASE HARDENED GUARD RINGS TO PROTECT THE MORTISE LOCK
 CYLINDER.
  
 IF THERE IS A REAR DOOR, IT SHALL BE EQUIPPED WITH
 180-DEGREE PEEPHOLE/ SECURITY VIEWER.
  

Review Stop STORM STORMWATER
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2012-07-10 10:18:481. PROVIDE RAISED CURB ALONG WEST SIDE OF 24-FOOT DRIVE
 AISLE ON THE WEST SIDE OF THE TRAILER.
 2. EROSION/SEDIMENT CONTROL PLAN TO BE PROVIDED FINAL
 ENGINEERING PLANS.
 3. NO DRAINAGE/GRADING PLANS OR CALCULATIONS PROVIDED.
  
 TRACY L. WARD, P.E.
 SENIOR STORM WATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120

Review Stop SURVEY SURVEYING
Rev No 1 Status P Date 07-03-2012 Cont ID  
Sent By vnoel Date 07-03-2012 Time 08:59 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2012-07-03 08:59:57NO COMMENTS.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status P Date   Cont ID  
Sent By   Date 07-06-2012 Time   Rev Time 0.00
Received By bcollins Date 07-06-2012 Time 15:35 Sent To  
Notes
2012-07-06 15:35:50NO COMMENTS

Review Stop Z ZONING
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By eschneid Date 01-15-2013 Time 10:49 Sent To  
Notes
2013-01-15 13:42:08 
  
  
  
  
  
 5) REPEAT COMMENT - UPDATED PARKING SPACE DETAILS SHALL
 BE PROVIDED ON THE PLANS TO SHOW THE ACCURATE
 CONDITIONS. - THIS COMMENT WAS ALSO MADE BY THE CITY'S
 PARKING DEPARTMENT.
  
  
  
 8) PLEASE NOTE THAT UPON FINAL APPROVAL, THERE WILL BE
 A NUMBER OF CONDITIONS RELATED TO THE PROVISION OF
 INFORMATION FOR THE BUILDING PERMIT TO ADDRESS COMMENTS
 MADE BY REVIEWERS FROM OTHER DEPARTMENTS.

Review Stop Z ZONING
Rev No 3 Status F Date 12-04-2012 Cont ID  
Sent By eschneid Date 12-04-2012 Time 13:42 Rev Time 0.00
Received By eschneid Date 12-04-2012 Time 09:40 Sent To  
Notes
2012-12-04 10:28:26CASE NO. ISPR 12-04
 AUTO BUILDERS EXPANSION
 5715 CORPORATE WAY
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX
 (6) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS MAY RESULT IN ADDITIONAL COMMENTS.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS
 FROM THE DATE OF THESE COMMENTS (FEBRUARY 4, 2012), THE
 CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER ACTION
 SHALL REQUIRE A NEW DEVELOPMENT APPLICATION.
  
 1) LANDSCAPE SHALL BE INSTALLED ALONG THE FRONT
 PROPERTY LINE.
  
 2) ADDITIONAL COMMENTS MAY BE PROVIDED UPON THE
 SUBMITTAL OF THE REVISED PLANS.
  
 3) PLEASE NOTE THAT UPON FINAL APPROVAL, THERE WILL BE
 A NUMBER OF CONDITIONS RELATED TO THE PROVISION OF
 INFORMATION FOR THE BUILDING PERMIT TO ADDRESS COMMENTS
 MADE BY REVIEWERS FROM OTHER DEPARTMENTS.

Review Stop Z ZONING
Rev No 2 Status F Date 10-09-2012 Cont ID  
Sent By eschneid Date 10-09-2012 Time 11:49 Rev Time 2.00
Received By eschneid Date 10-09-2012 Time 11:49 Sent To  
Notes
2012-10-09 14:34:09CASE NO. ISPR 12-04
 AUTO BUILDERS EXPANSION
 5715 CORPORATE WAY
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX
 (6) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS MAY RESULT IN ADDITIONAL COMMENTS.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS
 FROM THE DATE OF THESE COMMENTS (DECEMBER 9, 2012), THE
 CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER ACTION
 SHALL REQUIRE A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT PREVIOUSLY-ISSUED COMMENTS WERE NOT
 SUFFICIENTLY ADDRESSED; THEREFORE, THE APPLICANT WILL
 BE ACCESSED A RESUBMITTAL FEE. SUCH FEE WILL BE 20% OF
 THE ORIGINAL APPLICATION FEE ($200).
  
 1) REPEAT COMMENT - THE UTILITY PROVIDER APPROVAL
 LETTERS WERE NOT PROVIDED.
  
 2) THE TREE ALTERATION PERMIT SUBMITTED REQUIRES A $50
 APPLICATION FEE.
  
 3) THE LANDSCAPE PLAN AND DETAILS NEED TO BE CORRECTED
 AS FOLLOWS:
  
 A. THE SOUTHWEST CORNER OF THE SITE DOES NOT SHOW THE
 EXISTING DOUBLE TRUNK PALM TREE. ADDITIONALLY, THIS
 AREA OF THE SITE REQUIRES TWO (2) ADDITIONAL TREES -
 ONE (1) BETWEEN THE PROPOSED GREEN BUTTONWOOD AND THE
 EXISTING DOUBLE PALM AND ONE (1) TREE EAST OF THE
 DOUBLE PALM (NEAR THE EAST PROPERTY LINE.
  
 B. THERE IS NO SIGN LOCATED IN THE SOUTHEAST CORNER OF
 THIS SITE AS SHOWN ON THE LANDSCAPE PLAN.
  
 C. THERE ARE THREE (3) TIBOUCHINA GRANULOSA TREES AND
 ONE (1) WASHINGTONIA PALM THAT ARE SHOWN ON THE
 APPROVED LANDSCAPE PLAN AROUND THE BUILDING THAT ARE NO
 LONGER ON THE SITE AND NOT SHOWN ON THE NEW LANDSCAPE
 PLAN. IF THESE TREES ARE PLANNED TO BE NOT REINSTALLED
 AND BE REPLACED BY THE NEW TREES, THEN THIS SHALL BE
 REFLECTED ON THE TREE RELOCATION PLAN.
  
 D. THE LANDSCAPE CALCULATION TABLE IS MISLEADING. IT
 DOES NOT DIFFERENTIATE BETWEEN THE EXISTING PALMS AND
 TREES AND IT APPEARS TO EITHER COUNT OFF-SITE EXISTING
 TREES AS MEETING THE ON-SITE REQUIREMENT, COUNT
 INTERIOR TREES AS BUFFER TREES OR DOUBLE COUNT TREES
 TOWARD MEETING MULTIPLE BUFFER REQUIREMENTS. PLEASE
 NOTE THAT THE TYPES OF SOLITARY PALMS ON-SITE DO NOT
 COUNT TOWARD MEETING THE OPEN SPACE TREE REQUIREMENT.
  
 E. PROVIDE THE PALM CONVERSION TABLE.
  
 4) REPEAT COMMENT - PROVIDE WRITTEN VERIFICATION FROM
 THE CITY'S SANITATION DEPARTMENT THAT THE DUMPSTER AREA
 CAN STILL BE SUFFICIENTLY ACCESSED WITH THE
 RECONFIGURED DRIVE AISLE. THE CURRENT CONFIGURATION
 ALLOWS A STRAIGHT ENTRY TO THE GATES, WHICH IS NOT
 MAINTAINED UNDER THE PROPOSED PLAN. - THIS COMMENT WAS
 ALSO MADE BY THE CITY'S ENGINEERING SERVICES
 DEPARTMENT.
  
 5) REPEAT COMMENT - UPDATED PARKING SPACE DETAILS SHALL
 BE PROVIDED ON THE PLANS TO SHOW THE ACCURATE
 CONDITIONS. - THIS COMMENT WAS ALSO MADE BY THE CITY'S
 PARKING DEPARTMENT.
  
 6) REPEAT COMMENT - PROVIDE AN ELEVATION DRAWING OF THE
 TRAILER. WILL IT BE ELEVATED? WHAT IS THE HEIGHT? WHAT
 TYPE OF AC AND MECHANICAL EQUIPMENT WILL BE REQUIRED
 AND HOW WILL THIS BE SCREENED?
  
 7) ADDITIONAL COMMENTS MAY BE PROVIDED UPON THE
 SUBMITTAL OF THE REVISED PLANS.
  
 8) PLEASE NOTE THAT UPON FINAL APPROVAL, THERE WILL BE
 A NUMBER OF CONDITIONS RELATED TO THE PROVISION OF
 INFORMATION FOR THE BUILDING PERMIT TO ADDRESS COMMENTS
 MADE BY REVIEWERS FROM OTHER DEPARTMENTS.

Review Stop Z ZONING
Rev No 1 Status F Date 07-05-2012 Cont ID  
Sent By eschneid Date 07-05-2012 Time 08:52 Rev Time 3.00
Received By eschneid Date 07-05-2012 Time 08:52 Sent To  
Notes
2012-07-05 08:55:42CASE NO. ISPR 12-04
 AUTO BUILDERS EXPANSION
 5715 CORPORATE WAY
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX
 (6) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS MAY RESULT IN ADDITIONAL COMMENTS.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS
 FROM THE DATE OF THE PPRC MEETING (SEPTEMBER 11, 2012),
 THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER
 ACTION SHALL REQUIRE A NEW DEVELOPMENT APPLICATION.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($200).
  
 1) THE PALM BEACH COUNTY TRAFFIC CONCURRENCY APPROVAL
 LETTER WAS NOT PROVIDED.
  
 2) THE UTILITY PROVIDER APPROVAL LETTERS WERE NOT
 PROVIDED.
  
 3) A TREE ALTERATION PERMIT WAS NOT SUBMITTED FOR THE
 TREES BEING REMOVED AS PART OF THIS APPLICATION.
  
 4) THE WESTERN PERIMETER LANDSCAPE BUFFER SHALL BE
 PLANTED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE
 XIV, LANDSCAPE, OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS. THE REQUIRED FIVE (5) FOOT PLANTING STRIP
 SHALL NOT INCLUDE THE SIX (6) FOOT UTILITY EASEMENT AND
 BE PROTECTED FROM VEHICULAR ENCROACHMENT BY A TYPE D
 CURB. THE WESTERN DRIVE AISLE MAY BE NARROWED TO 20
 FEET WIDE AS THERE IS NO PARKING AT THIS LOCATION TO
 ACCOMMODATE THE REQUIRED LANDSCAPE BUFFER.
  
 5) PROVIDE LANDSCAPE DETAILS FOR THE ENTIRE SITE ON THE
 LANDSCAPE PLAN WHICH EITHER VERIFIES THAT THE SITE
 MEETS THE CITY'S LANDSCAPE PLANTING REQUIREMENTS FOR
 THE AFFECTED AREA OF WORK AND THAT ALL THE MATERIAL
 REQUIRED BY THE CURRENT LANDSCAPE PLAN APPROVED BY
 PERMIT NO. 97012222 IS STILL IN PLACE, OR WILL BE
 REPLACED. A COPY OF THE APPROVED LANDSCAPE PLAN WILL BE
 PROVIDED AT THE PPRC MEETING. PLEASE NOTE THAT A SITE
 VISIT VERIFIED THAT THERE IS MISSING LANDSCAPE.
  
 6) PROVIDE WRITTEN VERIFICATION FROM THE CITY'S
 SANITATION DEPARTMENT THAT THE DUMPSTER AREA CAN STILL
 BE SUFFICIENTLY ACCESSED WITH THE RECONFIGURED DRIVE
 AISLE. THE CURRENT CONFIGURATION ALLOWS A STRAIGHT
 ENTRY TO THE GATES, WHICH IS NOT MAINTAINED UNDER THE
 PROPOSED PLAN.
  
 7) THE ADA SPACES ADJACENT TO THE BUILDING APPEAR TO
 HAVE BEEN DESIGNED TO OVERHANG THE CURB BY TWO (2) FEET
 WITH A 16 FOOT PAVED DEPTH IN ORDER TO MAINTAIN THE 24
 FOOT DRIVE AISLE WIDTH. THE PLANS SHOW THE ADA ACCESS
 AREA AND THE PARKING SPACE EXTENDING INTO THE DRIVE
 AISLE. THIS SHALL NOT OCCUR.
  
 8) AS CAN BE SEEN ON THE LANDSCAPE PLAN APPROVED AS
 PART OF PERMIT NO. 97012222, THE ORIGINAL DESIGN OF THE
 PARKING WAS TO UTILIZE THE TWO (2) FOOT PARKING SPACE
 OVERHANG OPTION. THE SUBMITTED PLANS SHOW THE PARKING
 LOT STRIPPING TOO LONG AND EXTENDING INTO THE CODE
 REQUIRED 24 FOOT WIDE DRIVE AISLE. THE PLANS AND THE
 PARKING LOT SHALL REFLECT THE CORRECT 16 FOOT PARKING
 SPACE PAVEMENT DEPTH AND 24 FOOT WIDE DRIVE AISLES.
  
 9) UPDATED PARKING SPACE DETAILS SHALL BE PROVIDED ON
 THE PLANS TO SHOW THE ACCURATE CONDITIONS.
  
 10) PROVIDE AN ELEVATION DRAWING OF THE TRAILER. WILL
 IT BE ELEVATED? WHAT IS THE HEIGHT? WHAT TYPE OF AC AND
 MECHANICAL EQUIPMENT WILL BE REQUIRED AND HOW WILL THIS
 BE SCREENED?
  
 11) ADDITIONAL COMMENTS MAY BE PROVIDED UPON THE
 SUBMITTAL OF THE REVISED PLANS.
  
 12) THE TRAILER LOCATED ON THE SITE IS IN VIOLATION OF
 THE ZONING AND LAND DEVELOPMENT REGULATIONS AND SHALL
 BE REMOVED BY JULY 13, 2012. FAILURE TO REMOVE THE
 TRAILER WILL RESULT IN THE INITIATION OF CODE
 ENFORCEMENT ACTION.
  

  Print