Plan Review Details - Project Z10120004
Plan Review Stops For Project Z10120004
Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status F Date 01-19-2011 Cont ID  
Sent By bmoree Date 01-19-2011 Time 10:42 Rev Time 0.00
Received By bmoree Date 01-19-2011 Time 10:36 Sent To  
Notes
2011-01-19 10:42:281. CIVIL SITE PLAN REQUIRED DETAILING ANY EXTERIOR
 BUILDING SITE IMPROVEMENTS OR MODIFICATIONS FOR WORK ON
 PRIVATE PROPERTY OR PUBLIC RIGHT-OF-WAY.
 2. DETAIL SHEET PROPOSED MATERIAL TO BE USED IN
 ASSOCIATED SITE WORK. (ASPHALT, PARKING STOPS,
 THERMOPLASTIC, CURBING, ETC.)
 3. STORMWATER POLLUTION PREVENTION PLAN DETAILING THE
 BEST MANAGEMENT PRACTICES THAT WILL BE USED TO CONTAIN
 EROSION OR DEBRIS ON SITE DURING CONSTRUCTION.
  
 BRIAN R. MOREE
 ENGINGEERING CONSTRUCTION MANAGER
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 561-644-7270
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 01-19-2011 Cont ID  
Sent By mcarsill Date 01-19-2011 Time 10:14 Rev Time 0.00
Received By mcarsill Date 01-19-2011 Time 10:08 Sent To  
Notes
2011-01-19 10:14:412400 SOUTH DIXIE HIGHWAY
 ZBA 3275 (Z10120004)
  
 1. SUBMIT COMPLETE ARCHITECTURAL, ELECTRICAL,
 MECHANICAL, PLUMBING PLANS TO THE CONSTRUCTION SERVICES
 DEPARTMENT FOR REVIEW.
  
 2. THE EXISTING GARAGE SHOP AND PLANNED REMODELING IS
 TO COMPLY WITH THE INDUSTRIAL OCCUPANCY OF THE FLORIDA
 FIRE PREVENTION CODE.
  
 3. TACTILE SIGNAGE REQUIRED AT EXIT DOOR LOCATIONS.
  
 4. BUILDING ADDRESS IS REQUIRED ON THE PROPERTY. THE
 BUILDING ADDRESS SHALL BE A MINIMUM OF AT LEAST 6" HIGH
 AND AT LEAST 1" WIDE.
  
 5. PLEASE INDICATE THE NUMBER OF OCCUPANTS WHEN PLANS
 ARE SUBMITTED TO THE CONSTRUCTION SERVICES DEPARTMENT.
  
 APPROVED PROVISO
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION

Review Stop L LANDSCAPING
Rev No 1 Status F Date 01-19-2011 Cont ID  
Sent By rkussner Date 01-19-2011 Time 11:40 Rev Time 0.00
Received By rkussner Date 01-19-2011 Time 11:40 Sent To  
Notes
2011-01-19 12:40:10***LANDSCAPE REVIEW FAILED***
  
 PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORRMAT.
  
 1. PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR. THE LANDSCAPE PLAN SHALL BE SIGNED AND SEALED
 BY A REGISTERED LANDSCAPE ARCHITECT.
  
 2. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE
 EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE
 XERISCAPE DESIGN OPTIONS.
  
 3. PURSUANT TO SECTION 94-448 (D) (2), THE LANDSCAPE
 PLAN SHALL CONTAIN ALL OF THE ELEMENTS ENUMERATED IN
 THIS SECTION.
  
 4. PURSUANT TO SECTION 94-444 (B), OUTDOOR GARBAGE OR
 TRASH CONTAINERS AND ALL MECHANICAL EQUIPMENT SHALL NOT
 BE PERMITTED UNLESS APPROPRIATE SCREENING IS PROVIDED.
 PLEASE IDENTIFY THE LOCATION OF THESE ITEMS AND
 INDICATE THE MANNER IN WHICH SCREENING WILL BE
 PROVIDED.
  
 5. FOR THIS SITE TO CORRECTLY FUNCTION AND MEET MINIMUM
 REQUIREMENTS, CERTAIN AREAS OF ASPHALT WILL NEED TO BE
 REMOVED AND OTHER AREAS WILL NEED TO BE PAVED.
  
 6. PURSUANT TO SECTION 94-443 (C) (5) (A), LANDSCAPE
 AREAS SHALL BE SEPARATED FROM VEHICULAR USE AREAS BY
 NONMOUNTABLE, CONCRETE CURBING FO THE TYPE
 CHARACTERIZED AS 'TYPE D'.
  
 7. PURSUANT TO SECTION 94-442 (D) PRIVATE LAND AND
 PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK
 SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN
 SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS
 SHALL BE SODDED. THIS WOULD INCLUDE THE ENTIRE SITE AND
 RIGHT-OF-WAY.
  
 8. PURSUANT TO SECTION 94-445 (4) (G) (3) (II), IN ALL
 AREAS THAT ARE TO BE PLANTED IN A CULTIVATED LANDSCAPE,
 IRRIGATION SYSTEMS SHALL BE DESIGNED TO HAVE 120
 PERCENT COVERAGE, INCLUDING THE RIGHT-OF-WAY.
  
 9. PURSUANT TO SECTION 94-443 (E) (1), AT LEAST 30
 PERCENT OF THE LINEAR FEET AROUND THE EXTERIOR OF ALL
 COMMERCIAL STRUCTURES SHALL BE PLANTED WITH TREES,
 SHRUBS OR HEDGES. AT A MINIMUM, A LANDSCAPE STRIP SHALL
 BE CUT OUT ALONG THE NORTH BUILDING ELEVATION AND
 LANDSCAPED.
  
 10. PURSUANT TO SECTION 94-443 (C) (3) (A), EACH ROW OF
 PARKING SPACES SHALL BE TERMINATED BY LANDSCAPE ISLANDS
 OF NOT LESS THAN FIVE FEET IN WIDTH AND NOT LESS THAN
 THE LENGTH OF THE ADJACENT PARKING STALL. THE
 LANDSCAPED ISLAND SHALL HAVE A MINIMUM RADIUS OF 2 1/2
 FEET AT ITS END SO AS TO ALLOW CAR MANEUVERING. THE
 LANDSCAPED ISLAND SHALL CONTAIN AT LEAST ONE SHADE OR
 FLOWERING TREE.
  
 11.PURSUANT TO SECTION 94-443 (B) (1), FOR
 NONRESIDENTIAL USES, THE LANDSCAPE BUFFER STRIP SHALL
 BE AT LEAST FIVE FEET WIDE ALONG THE ENTIRE EDGE OF
 PROPERTY, WHEN ADJACENT TO A PUBLIC THOROUGHFARE. THIS
 APPLIES TO THE WEST AND NORTH SIDES OF THE SITE. A
 HEDGE PLANTED ALONG THE INTERIOR PERIMETER OF THE
 LANDSCAPE SETBACK AND AT LEAST ONE SHADE OR FLOWERING
 TREE SHALL BE PLANTED IN A REQUIRED BUFFER STRIP FOR
 EACH 30 LINEAR FEET OR FRACTION THEREOF.
  
 12. PURSUANT TO SECTION 94-443 (A) (2) AT LEAST ONE
 SHADE OR FLOWERING TREE SHALL BE PLANTED IN A REQUIRED
 BUFFER FOR EACH 30 LINEAR FEET OR PORTION THEREOF
 WITHIN THE LANDSCAPE STRIP THAT BUFFERS A
 NONRESIDENTIAL USE THAT IS ADJACENT TO RESIDENTIAL
 PROPERTY. IN ADDITION, A REQUIRED HEDGE SHALL BE
 PLANTED WITH TWO-FOOT TO THREE-FOOT INTERVALS FOR THE
 LENGTH OF THE BUFFER.
  
 13. PURSUANT TO SECTION 94-445 (4) (I), ALL PROHIBITED
 TREE SHALL BE REMOVED FROM THE SITE, INCLUDING THE
 AUSTRALIAN PINE THAT IS GROWING ALONG THE EAST
 PERIMETER OF THE SITE.
  
 14. PURSUANT TO SECTION 94-445 (4) (K), FICUS SPECIES
 PLANTED WITHIN 15 FEET OF ANY STRUCTURE OR UTILITY
 SHALL BE PERMITTED ONLY IF THEY ARE CONTAINED IN A
 PLANTER OR MAINTAINED AS A HEDGE WHICH IS CONSTANTLY
 CULTIVATED AND DOES NOT EXCEED THE HEIGHT LIMITATIONS
 AS PROVIDED IN SECTION 94-302. THE FICUS TREES ALONG
 THE EAST PROPERTY LINE BEHIND THE BUILDING WERE PLANTED
 AS A HEDGE. THEY SHALL BE CUT BACK TO HEDGE HEIGHT OR
 REMOVED WITH A NEW HEDGE TO BE INSTALLED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop POLICE POLICE
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2011-01-26 10:39:36NO COMMENTS

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 01-18-2011 Cont ID  
Sent By vnoel Date 01-18-2011 Time 10:21 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2011-01-18 10:30:091. SURVEY NEEDS TO BE WITHIN 1 YEAR OLD. SURVEY
 PROVIDED IS OVER 13 YEARS.
 2. UNITY OF TITLE WILL BE REQUIRED.
 3. ADDITIONAL R/W FOR DIXIE HWY. NEEDS TO BE SHOWN PER
 FDOT MAINT. MAP IN ROAD PLAT BOOK 9, PG. 15.
 4. PLAT OF EL CID ADDITION CONTAINS A R/W DEDICATION
 OVER THE WEST 10' OF LOTS 1-5, BLOCK 11.
 5. NOTE ON SURVEY RECOMMENDS TITLE VERIFICATION AND IS
 CERTIFED TO TWO TITLE COMPANIES. HAS TITLE BEEN
 RESEARCHED?

Review Stop Z ZONING
Rev No 1 Status F Date 02-04-2011 Cont ID  
Sent By astelly Date 02-04-2011 Time 13:18 Rev Time 0.00
Received By astelly Date 02-04-2011 Time 13:18 Sent To  
Notes
2011-02-04 13:54:39AN UPDATED SURVEY IS REQUIRED.
  
 PARKING STALLS MUST BE DOUBLED STRIPED AND DIMENSIONED
 PER THE REQUIREMENTS OF SEC. 94-485, FIG. XV-2 OF THE
 ZONING CODE.
  
 THE DIMENSIONS OF ALL DRIVE AISLES MUST BE SHOWN.
  
 THE ADA ROUTE BETWEEN THE PARKING AND THE BUILDING MUST
 BE SHOWN.
  
 LANDSCAPE BUFFERS MUST BE INSTALLED IN ACCORDANCE WITH
 THE CITY'S LANDSCAPE CODE.
  
 ALL BUILDING SETBACKS MUST BE SHOWN ON THE UPDATED
 SURVEY. A WAIVER WILL BE REQUIRED IF THE REAR SETBACK
 IS LESS THAN 50 FEET.
  
 THE LOCATION FOR ALL RECEPTACLES FOR THE STORAGE OF
 COMBUSTIBLE MATERIALS MUST SHOWN ON THE PLANS AND MUST
 BE LOCATED WITHIN THE BUILDING SETBACKS. IF THE STORAGE
 RECEPTACLES ARE GREATER THAN 200 GALLONS, THEY MUST BE
 LOCATED UNDERGROUND.
  
 IF THE BUILDING HAS BEEN VACANT FOR MORE THAN ONE YEAR,
 THE PROPERTY OWNER MUST REMOVE OR TREAT ALL FLAMMABLE
 STORAGE TANKS ON SITE. A BOND SUFFICIENT TO COVER THE
 REMOVAL COST MUST BE POSTED PRIOR TO THE ISSUANCE OF A
 BUILDING PERMIT.
  
 ALL PITS AND HYDRAULIC HOISTS MUST BE LOCATED WITHIN
 THE BUILDING.
  
 ALL SERVICES - LUBRICATION, WASHING, REPAIR MUST BE
 CONDUCTED WITHIN THE BUILDING.
  
 INGRESS AND EGRESS MUST BE PROVIDED FROM S. DIXIE.
 TRAFFIC FROM THE BUSINESS CANNOT TRAVEL THROUGH THE
 RESIDENTIAL NEIGHBORHOOD.
  
  
  

  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved