Review Stop B1 BUILDING (STRUCTURAL)
Rev No 1 Status P Date 12-08-2010 Cont ID  
Sent By lmartine Date 12-08-2010 Time 11:05 Rev Time 0.00
Received By lmartine Date 12-08-2010 Time 10:52 Sent To  
Notes
2010-12-08 11:05:54NO COMMENTS

Review Stop ENG - PPRC ENGINEERING - PPRC
Rev No 1 Status P Date   Cont ID  
Sent By   Date 12-08-2010 Time   Rev Time 0.00
Received By bmoree Date 12-08-2010 Time 09:24 Sent To  
Notes
2010-12-08 09:41:361. CIVIL DESIGN PLANS SHALL INCLUDE STORMWATER
 MANAGEMENT PLAN AND POLLUTION PREVENTION PLAN.
  
 BRIAN R. MOREE
 ENGINEERING CONSTRUCTION SUPERVISOR
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 561-494-1098 OFFICE
 561-644-7270 MOBILE

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 01-11-2011 Cont ID  
Sent By mcarsill Date 01-11-2011 Time 14:25 Rev Time 0.00
Received By mcarsill Date 01-11-2011 Time 14:25 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 11-22-2010 Cont ID  
Sent By mcarsill Date 11-22-2010 Time 14:40 Rev Time 0.00
Received By mcarsill Date 11-22-2010 Time 14:33 Sent To  
Notes
2010-11-22 14:40:11FORMAL SITE PLAN REVIEW CASE NO. 10-5 (Z10110008)
 205 NORTH DIXIE HIGHWAY
  
 1. THE COVER SHEET INDICATES AN ADDRESS OF 205 NORTH
 DIXIE HIGHWAY. THE WORK APPEARS TO BE LOCATED BEHIND
 THE HISTORIC COURT HOUSE (300 NORTH DIXIE HIGHWAY) AND
 WEST OF THE GOVERNMENTAL CENTER (301 NORTH OLIVE
 AVENUE). THE COVER SHEET ADDRESS DOES NOT APPEAR TO
 CORRESPOND TO THE ADDRESSES LISTED.
  
 2. ON SHEET A-100 THE EXISTING FIRE HYDRANT APPEARS TO
 BE DIRECTLY NEXT TO THE CONCRETE WALK. DOES THE
 LOCATION INTERFERE WITH MOVEMENT ON THE CONCRETE WALK.
  
 3. PLEASE INDICATE WHAT MATERIALS ARE PLANNED TO BE
 STORED IN THE STORAGE AREA.
  
 4. THE CANOPY DISPLAYED ON SHEET A-100 IS TO BE
 CONSTRUCTED OF FIRE RESISTANT MATERIALS.
  
  
 DENIED
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION

Review Stop L LANDSCAPING
Rev No 3 Status P Date 01-20-2011 Cont ID  
Sent By rkussner Date 01-20-2011 Time 14:53 Rev Time 0.00
Received By rkussner Date 01-20-2011 Time 14:53 Sent To  
Notes
2011-01-20 14:55:16LAYBAN REEVES FROM THE PARKS DEPARTMENT WILL BE
 RELOCATING THE SIX (6) GUMBO LIMBO TREES FROM THE SITE
 AND INSTALLING THEM ELSEWHERE ON CITY PROPERTY.

Review Stop L LANDSCAPING
Rev No 2 Status F Date 01-07-2011 Cont ID  
Sent By rkussner Date 01-07-2011 Time 16:40 Rev Time 0.00
Received By rkussner Date 01-07-2011 Time 16:40 Sent To  
Notes
2011-01-07 16:53:23***LANDSCAPE REVIEW FAILED***
  
 PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT.
  
 1. REPEAT COMMENT: EVERY EFFORT SHALL BE MADE TO SAVE
 THE LIVE OAK AND GUMBO LIMBO TREES BY RELOCATING THEM
 ON SITE OR ELSEWHERE WITHIN THE CITY LIMITS.
  
 2. REPEAT COMMENT: PURSUANT TO SECTION 94-444 (B),
 OUTDOOR INCINERATORS, GARBAGE OR TRASH CONTAINERS,
 TRASH RECEPTACLES, FUEL TANKS, STORAGE RACKS AND OTHER
 MECHANICAL EQUIPMENT SHALL BE SCREENED. WALLS SHALL BE
 LANDSCAPED WITH SHRUBS AND HEDGES PLANTED AT TWO-FOOT
 INTERVALS. THE TRANSFORMER ON THE NORTH SIDE OF THE
 SITE IS OPEN TO THE STREET. PLEASE PROVIDE SCREENING
 FROM THE PUBLIC VIEW. VISION OBSCURING GATES SHALL BE
 INSTALLED ON THE ENCLOSURE. SCREENING ALONG THE OTHER
 SIDES APPEARS TO BE SATISFACTORY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop L LANDSCAPING
Rev No 1 Status F Date 12-08-2010 Cont ID  
Sent By rkussner Date 12-08-2010 Time 17:10 Rev Time 0.00
Received By rkussner Date 12-08-2010 Time 17:10 Sent To  
Notes
2010-12-08 17:23:38***LANDSCAPE REVIEW FAILED***
  
 PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT.
  
 1. PLEASE APPLY FOR A TREE ALTERATION PERMIT. THE
 APPLICATION IS AVAILABLE AT THE FRONT DESK OF THE
 PLANNING & ZONING DEPARTMENT. WE WILL NEED THE
 COMPLETED APPLICATION AND TWO SETS OF PLANS THAT
 IDENTIFY THE TREES TO BE REMOVED. EVERY EFFORT SHALL BE
 MADE TO SAVE THE TREES BY RELOCATING THEM ON SITE OR
 ELSEWHERE WITHIN THE CITY LIMITS.
  
 2. PURSUANT TO SECTION 94-444 (B), OUTDOOR
 INCINERATORS, GARBAGE OR TRASH CONTAINERS, TRASH
 RECEPTACLES, FUEL TANKS, STORAGE RACKS AND OTHER
 MECHANICAL EQUIPMENT SHALL BE SCREENED. WALLS SHALL BE
 LANDSCAPED WITH SHRUBS AND HEDGES PLANTED AT TWO-FOOT
 INTERVALS. THE TRANSFORMER ON THE NORTH SIDE OF THE
 SITE IS OPEN TO THE STREET. PLEASE PROVIDE SCREENING
 FROM THE PUBLIC VIEW.
  
 3. CREDIT WAS TAKEN FOR THE USE OF A MOISTURE SENSING
 CONTROLLER OTHER THAN A RAIN SWITCH. PLEASE IDENTIFY
 THE TYPE OF EQUIPMENT TO BE USED OR DELETE THE FIVE
 POINTS FROM THE TOTAL.
  
 4. TREES AND SHRUBS SHALL BE PLANTED AT OR SLIGHTLY
 ABOVE GRADE WITH ONLY A ONE INCH LAYER OF MULCH TO BE
 APPLIED OVER THE ROOT BALL. THE THREE INCH LAYER OF
 MULCH IS TO BE APPLIED OUTSIDE OF THE ROOT BALL.
  
 5. STAFF RECOMMENDS THAT ROSES BE PLANTED TO
 COMMEMORATE ROSE KENNEDY'S ROSE GARDEN IN ADDITION TO
 THE PLAQUE BEING PROPOSED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop POLICE POLICE
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2010-12-07 10:24:18WHAT LIGHTING WILL BE INSTALLED. LOOKING FOR PEDESTRIAN
 SCALE ALONG THE PTHS AND SIDEWALK, PAVILLION STRUCTURE.
 MOVE THE BIKE RACKS TO A MORE HIGH TRAFFIC AREA
 BENCHES SHOULD BE DIVIDED STYLE
  
 A. LANDSCAPING SHALL NOT CONFLICT WITH LIGHTING (TO
 INCLUDE LONG-TERM TREE CANOPY GROWTH).
 B. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR
 DUSK TO DAWN OPERATION FOR ALL PEDESTRIAN SIDEWALKS.
 C. LIGHTING FOR ENTRANCE SIGN TO PATHWAYS SHALL BE
 PROVIDED TO ALLOW NIGHTTIME USE OF PEDESTRIAN WALKWAYS.
 D. BENCHES WILL BE DIVIDED STYLE SEATING.
 E. SHALL BE DESIGNED TO MAXIMIZE NATURAL SURVEILLANCE
 OF THE PEDESTRIAN USERS THROUGH SELECTIVE VEGETATIVE
 MANAGEMENT PRACTICES.
 F. GROUND COVER SHALL BE NO HIGHER THAN 24 INCHES, WITH
 TREES HAVING A MINIMUM 7-FOOT CLEAR TRUNK SPACE FOR A
 NATURAL SURVEILLANCE WINDOW.
 G. INSTALL 12-FOOT PEDESTRIAN-SCALE LIGHTING. AS A
 GENERAL RULE, THE MINIMUM LIGHTING INTENSITY AT ANY
 POINT ALONG THE PATH SHALL BE AT 0.6 FOOT-CANDLES.
 H. SIGHT LINES SHALL HAVE A 12-FOOT CLEAR DISTANCE
 SPACE AT ENTRY POINTS, CURVES, MERGERS, INTERSECTIONS,
 ETC.
  

Review Stop STORM STORMWATER
Rev No 1 Status P Date 01-10-2011 Cont ID  
Sent By vnoel Date 12-07-2010 Time 06:43 Rev Time 0.00
Received By vnoel Date 12-07-2010 Time 06:41 Sent To  
Notes
2010-12-07 06:42:52WHEN CONSTRUCTION DOCUMENTS ARE SUBMITTED FOR
 PERMITTING , THE APPLICANT SHOULD INCLUDE COPIES OF THE
 FOLLOWING :
 1) SFWMD ERP ( OR PERMIT MOD )
 2) DRAINAGE REPORT , CALCULATIONS & GEOTECHNICAL
 RESULTS
 3) ALL COMPLETE STORMWATER MANAGEMENT PLAN FOR USE
 DURING CONSTRUCTION
  
  
 THE INCREASE IN IMPERMEABLE AREA MAY BE COVERED UNDER
 THE PRIOR IMPROVEMENTS IF SO THE APPLICATION SHOULD
 INDICATE SUCH.

Review Stop SURVEY SURVEYING
Rev No 1 Status P Date 12-02-2010 Cont ID  
Sent By vnoel Date 12-02-2010 Time 14:21 Rev Time 0.00
Received By vnoel Date   Time   Sent To  
Notes
2010-12-02 14:21:07NO COMMENTS

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status P Date   Cont ID  
Sent By   Date 12-06-2010 Time   Rev Time 0.00
Received By bcollins Date 12-06-2010 Time 08:48 Sent To  
Notes
2010-12-06 08:48:04NO COMMENTS

Review Stop Z ZONING
Rev No 1 Status P Date 12-06-2010 Cont ID  
Sent By aaponte Date 12-06-2010 Time 09:42 Rev Time 0.00
Received By aaponte Date 12-06-2010 Time 09:41 Sent To  
Notes
2010-12-06 11:57:091. NORTHERN SIDEWALK IS A DEAD - END. PLEASE CONSIDER
 CONNECTING IT TO THE 3RD STREET SIDEWALK OR TO THE
 STORAGE ENTRANCE.
 2. STORAGE ENTRANCE NEEDS A HARD SURFACE (SIDEWALK) TO
 CONNECT TO PROPOSED SIDEWALK.
 3. PLEASE CORRECT NOTE ON LP-1 . EXISTING ZONING
 DESIGNATION IS QGD-10.
  
 GENERAL DESIGN COMMENTS:
 THE PLANNING DEPARTMENT APPLAUDS THE COUNTY'S EFFORTS
 TO CREATE A UNIQUE OPEN SPACE AT THE RESTORED HISTORIC
 COURTHOUSE PROPERTY. THE CONSTRUCTION OF A PUBLIC
 ASSEMBLY PLAZA WILL ENHANCE THE CHARACTER OF THE SPACE
 AND THE URBAN LIFE OF DOWNTOWN.
 IN REFERENCE TO THE PROPOSED DESIGN, STAFF HAS THE
 FOLLOWING CONCERNS AND COMMENTS:
 - THE PROPOSED GEOMETRY (CIRCULAR PATTERN) SEEMS
 FOREIGN TO THE COMPLEX WHICH, BASED ON ITS EXISTING
 SIDEWALK AND PLANTING SCHEME, FOLLOWS A VERY ORTHOGONAL
 PATTERN.
 - THE PROPOSED THREE DIMENSIONAL SCULPTURAL INTENT OF
 THE STRUCTURE IS DIMINISHED BY THE PROPOSED FLAT ROOF.
 - THE SELECTED NATIVE PLANT MATERIAL REQUIRES AN
 UPGRADE OF THE ENTIRE SITE TO INTEGRATE THE NEW
 PROPOSAL WITH THE EXISTING.
 - CONSIDERATION SHOULD BE GIVEN TO THE COLOR SCHEME
 UTILIZING BRONZE OR GREEN COLORED METAL MATERIALS TO
 RELATE TO BOTH BUILDINGS AND LANDSCAPING.
 - RECONSIDERATION OF THE STRUCTURAL ELEMENT OF THE BELL
 TO ENHANCE THE FEATURE.
  
  
  

  Print