Plan Review Details - Project Z10050016
Plan Review Stops For Project Z10050016
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 06-09-2010 Cont ID  
Sent By lmartine Date 06-09-2010 Time 08:19 Rev Time 0.00
Received By lmartine Date 06-09-2010 Time 08:19 Sent To  
Notes
2010-06-09 08:19:28NO COMMENTS

Review Stop ENG-P ENGINEERING PLANNING REVIEW
Rev No 1 Status P Date 06-02-2010 Cont ID  
Sent By efabian Date 06-02-2010 Time 14:15 Rev Time 1.00
Received By efabian Date 06-02-2010 Time 14:15 Sent To  
Notes
2010-06-02 14:25:18NO COMMENTS

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 05-28-2010 Cont ID  
Sent By mcarsill Date 05-28-2010 Time 12:29 Rev Time 0.00
Received By ssamuels Date 06-01-2010 Time 17:38 Sent To  
Notes
2010-05-28 12:29:27PLANNING BOARD CASE 1217I Z10050016 AND Z10050017
 CATALINA MAJOR PD AMENDMENT
  
 1. A KNOX-BOX KEY SWITCH IS REQUIRED TO OPERATE THE
 ENTRY GATE. THIS DEVICE CAN BE ORDERED AT KNOXBOX.COM.
  
 2. BUILDING ADDRESSES ARE REQUIRED ON PROPER ELEVATION.
 A MINIMUM OF AT LEAST 6" AND AT LEAST 1" WIDE NUMBERS
 ARE REQUIRED.
  
 3. ALL THREE STORY BUILDINGS ARE REQUIRED TO BE FIRE
 SPRINKLER PROTECTED IN ACCORDANCE WITH FS 553.895 (2)
  
 4. NO FIRE HYDRANTS DISPLAYED ON THE DRAWINGS. PLEASE
 ILLUSTRATE ALL NEW AND EXISTING FIRE HYDRANTS.
  
 5. ALL CONSTRUCTION, DEMOLITION, AND RENOVATION TO
 COMPLY WITH NFPA 241.
  
  
 DENIED
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION
 (561) 804-4724 PHONE
 (561) 804-4774 FAX

Review Stop L LANDSCAPING
Rev No 1 Status F Date 06-07-2010 Cont ID  
Sent By rkussner Date 06-07-2010 Time 14:02 Rev Time 0.00
Received By rkussner Date 06-07-2010 Time 14:01 Sent To  
Notes
2010-06-07 16:36:40***LANDSCAPE REVIEW FAILED***
  
 PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT.
  
 1. THE LANDSCAPE CALCULATIONS ARE INCORRECT. THE OPEN
 SPACE IS CALCULATED BY TAKING THE TOTAL LOT SQUARE
 FOOTAGE AND DEDUCTING THE BUILDING COVERAGE. THAT
 TOTALS 386,766 SQUARE FEET AND NOT 366,025 AS INDICATED
 ON THE PLAN. OTHER REQUIRED CALCULATIONS ARE MISSING.
  
 2. PURSUANT TO SECTION 94-443 (D) (2) (A), SHADE TREES
 TO BE PLANTED AND LANDSCAPED ON EXTERIOR OF ALL
 STRUCTURES AS REQUIRED BY THE FOLLOWING: AT LEAST TWO
 SHADE OR FLOWERING TREES FOR EACH DWELLING UNIT FOR
 MULTIFAMILY RESIDENTIAL STRUCTURES WITH TWO TO FIVE
 UNITS PER STRUCTURE, AND AT LEAST ONE SHADE OR
 FLOWERING TREE FOR EACH DWELLING UNIT FOR MULTIFAMILY
 RESIDENTIAL STRUCTURES WITH SIX OR MORE UNITS PER
 STRUCTURE. THIS SHALL BE ADDED INTO THE CALCULATIONS.
  
 3. PURSUANT TO SECTION 94-444 (B), MECHANICAL EQUIPMENT
 SHALL BE SCREENED. THE AIR CONDITIONING UNITS SHALL BE
 SCREENED BY FENCES OR LANDSCAPING.
  
 4. MUCH OF THE PROPOSED LANDSCAPING IS SHOWN WITHIN
 VARIOUS UTILITY EASEMENTS. IN ORDER TO APPROVE SUCH
 PLANTING, THE APPLICANT SHALL PROVIDE LETTERS OF
 APPROVAL FROM THE AFFECTED UTILITY COMPANIES.
  
 5. PURSUANT TO SECTION 94-445 (4) (I), ALL PROHIBITED
 TREES, THAT INCLUDES BUT IS NOT LIMITED TO AUSTRALIAN
 PINE, BRAZILIAN PEPPER, EARLEAF ACACIA AND MELALEUCA,
 SHALL BE REMOVED FROM THE DEVELOPMENT SITE.
  
 6. PURSUANT TO SECTION 94-446 (2), LANDSCAPING SHALL BE
 MAINTAINED IN GOOD CONDITION,SHALL PRESENT A HEALTHY,
 NEAT AND ORDERLY APPEARANCE, AND SHALL BE FREE FROM
 REFUSE AND DEBRIS. ALL UNHEALTHY OR DEAD MATERIAL SHALL
 BE REPLACED. MOST OF THE PERIMETER PLANTING WAS WEED
 INFESTED AND SOMEWHAT OVERGROWN WITH VINES. THE BEDS
 SHALL BE CLEANED UP AND REPLANTED WHERE NECESSARY. ALL
 EXISTING TREE STAKING MATERIAL SHALL BE REMOVED AND ALL
 OF THE TREES SHALL BE LIMBED UP AND CORRECTIVELY PRUNED
 BY A CERTIFIED ARBORIST.
  
 7. THE LOCATION AND SPECIES OF ALL PROPOSED TREES SHALL
 COMPLY WITH THE FPL "PLANT THE RIGHT TREE IN THE RIGHT
 PLACE" GUIDELINES THAT RESTRICTS TREE SPECIES IN
 RELATION TO OVERHEAD POWER LINES.
  
 8. PURSUANT TO SECTION 94-445 (2), ALL PLANT MATERIAL
 SHALL BE FLORIDA NUMBER ONE GRADE OR BETTER. ALL
 EXISTING TREES AND SHRUBS TO REMAIN SHALL MEET THESE
 STANDARDS.
  
 9. PURSUANT TO SECTION 94-445 (4) (G) (4), WHEREVER
 FEASIBLE, SPRINKLER HEADS IRRIGATION LAWNS OR OTHER
 HIGH WATER DEMAND LANDSCAPE AREAS SHALL BE CIRCUITED SO
 THAT THEY ARE ON A SEPARATE ZONE OR ZONES FROM THOSE
 IRRIGATING TREES, SHRUBBERY OR OTHER REDUCED WATER
 REQUIREMENT AREAS. TO ACCOMPLISH THIS AND IN KEEPING
 WITH XERISCAPE GUIDELINES, STAFF RECOMMENDS THAT GROUND
 COVER BE USED INSTEAD OF SOD IN SMALL CONFINED AREAS
 SUCH AS BETWEEN THE PROPOSED HEDGE AND SIDEWALKS IN
 FRONT OF THE BUILDINGS AND IN THE LANDSCAPE SEPARATORS
 BETWEEN THE DRIVEWAYS. THE TREE AND PALM GROUPINGS
 SHALL ALSO BE UNDER PLANTED WITH PLANT MATERIAL SUCH AS
 FAKAHATCHEE GRASS, SAW PALMETTO AND FIREBUSH. THESE
 BEDS CAN BE PLACED ON SEPARATE ZONES FROM THE LAWN
 AREAS.
  
 10. STAFF RECOMMENDS THE USE OF VERTICAL LANDSCAPE
 ELEMENTS WITHIN THE FOUNDATION PLANTING TO ACCENTUATE
 THE ARCHITECTURE AND SOFTEN THE FACADE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop PARK PARKING
Rev No 1 Status P Date 06-01-2010 Cont ID  
Sent By ssamuels Date 06-01-2010 Time 17:40 Rev Time 0.00
Received By ssamuels Date   Time   Sent To  
Notes
***NONE***

Review Stop STORM STORMWATER
Rev No 1 Status P Date 06-07-2010 Cont ID  
Sent By jrenault Date 06-07-2010 Time 12:53 Rev Time 0.00
Received By jrenault Date 06-07-2010 Time 12:52 Sent To  
Notes
2010-06-07 12:56:28NO COMMENT. PROJECT SITE ALREADY HAS A SFWMD ERP.

Review Stop SURVEY SURVEYING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2010-06-08 06:43:16SEE COMMENTS FOR Z10050017 CONCERNING MAJOR SUB'D &
 PLAT.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By bcollins Date 06-07-2010 Time 17:05 Sent To  
Notes
2010-06-07 17:08:13H/C AND REGULAR SPACE NEXT TO REC/POOL AREA SEEM
 DIFFICULT TO MANEUVRE OUT OF. ALSO NO TURN AROUND
 PROVIDED AT THAT LOCATION.

Review Stop Z ZONING
Rev No 1 Status P Date 06-09-2010 Cont ID  
Sent By kdfreema Date 06-09-2010 Time 08:21 Rev Time 0.00
Received By kdfreema Date 06-09-2010 Time 08:21 Sent To  
Notes
2010-06-09 08:37:25NO TECHNICAL COMMENTS.
  
 PLEASE NOTE, HOWEVER, THAT THE SITE IS BECOMING
 OVERGROWN WITH NUMEROUS INVASIVE/EXOTIC SPECIES HAVING
 BECOME ESTABLISHED. ADDITIONALLY, THE STAKING IS STILL
 ON MANY OF THE TREES WHICH, IF NOT REMOVED, WILL
 COMPROMISE THE LONG-TERM VIABILITY OF THE TREES. THIS
 APPLICATION WILL NOT BE SCHEDULED BEFORE CITY
 COMMISSION UNTIL THESE TWO ISSUES ARE REMEDIED.
  
 PLEASE CONTACT KELLY FREEMAN, GIS PLANNER, AT
 561-822-1458 OR [email protected] WITH QUESTIONS.