2010-05-20 15:35:38BUILDING REVIEW COMMENTS
  
  
 2007 FBC,
  
 11-4.3.2
 PROVIDE ACCESSIBLE ROUTE FROM THE PUBLIC RIGHT-OF-WAY
 TO THE BUILDING ENTRANCE.
  
 11-4.6
 SHOW COMPLIANCE FOR THE ACCESSIBLE PARKING. INCLUDING
 THE ROUTE AND REQUIRED SIGNAGE.
  
  
  
 LUIS MARTINEZ
 805-6710

Review Stop ENG-APP ENGINEERING APP. REVIEW
Rev No 2 Status F Date 05-13-2010 Cont ID  
Sent By mgonzale Date 05-13-2010 Time 11:50 Rev Time 1.00
Received By mgonzale Date 05-13-2010 Time 11:50 Sent To  
Notes
2010-05-13 12:13:38EXISTING FACILITIES MAY REQUIRE UPGRADES DUE TO FAILURE
 OR INSUFFICIENCY OF STORMWATER SYSTEM IF DISTURBED DUE
 TO TANK CONSTRUCTION.
  
 CREATING LARGER WELL DEFINED NATURAL LANDSCAPING AREAS
 WILL HELP TO LOWER STORMWATER DISCHARGE TO LOCAL
 SYSTEMS.
  
 ANY NEW IMPROVEMENT WILL ALSO DECREASES POLLUTANT AND
 SEDIMENT LOADING TO AREA STORMWATER SYSTEMS.
  
 IT WILL BE REQUIRED THAT ALL SITE IMPROVEMENTS BE
 SUBMITTED TO CITY ENGINEERING SERVICES DEPARTMENT IN A
 TOPOGRAPHIC SURVEY (AS-BUILT) PRIOR TO C.O. (2 PAPER
 COPIES AND ONE PDF SCANNED ON A CD)
  
 SURVEY WILL NEED TO REFLECT NEW OR ABANDONED EASEMENTS,
 EXISTING AND NEW ELEVATIONS ALONG WITH PERVIOUS AND
 IMPERVIOUS CALCULATIONS.
 PURPOSE OF SURVEY WILL BE TO DETERMINED THAT NO
 SIGNIFICANT CHANGE IN TOPO WAS MADE AND TO UPDATE THE
 OWNER'S STORMWATER ACCOUNT.
  
 CONCRETE AREA BEHIND SIDEWALK BY THE FIRE HYDRANT NOT
 MEET A.D.A. REQUIREMENTS, IT MUST BE REMOVED AS IT
 COULD BE A LIABILITY FOR THE CITY OF WPB AND/OR
 PROPERTY OWNER.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  
  
  
  
  

Review Stop ENG-APP ENGINEERING APP. REVIEW
Rev No 1 Status F Date 03-22-2010 Cont ID  
Sent By vnoel Date 03-22-2010 Time 12:11 Rev Time 3.00
Received By mgonzale Date 03-22-2010 Time 09:20 Sent To  
Notes
2010-03-30 12:11:52ON 3/16/10 I INSPECTED THE STORE UNDER THE CONVENIENCE
 STORE ORDINANCE 3980-06. THE STORE IS IN THE MIDDLE OF
 REMODELING. BELOW ARE THE AREAS THAT I WAS UNABLE TO
 INSPECT:
  
 * I WAS UNABLE TO INSPECT THE CAMERA SECURITY SYSTEM TO
 SEE IF IT IS FUNCTIONING, THE UNIT MUST BE ABLE TO
 PRINT A CLEAR IMAGE UPON REQUEST, NO MAINTANCE LOG KEPT
 * THE PARKING LOT ILLUMINATION
 * NO CASH MANAGEMENT POLICY ON SITE
 * NO ROBBERY PREVENTION TRAINING HAS BEEN PROVIDED TO
 EMPLOYEES
 * UNABLE TO TRIGGER SILENT ALARM
  
 I SPOKE WITH MANAGER AND ADVISED THAT I WILL DROP OFF A
 TRAINING MANUEL FOR THEM TO FOLLOW FOR THE TRAINING AND
 POLICY.
  
 THE PROPERTY HAS OVERGROWTH THAT SHOULD BE CLEANED OUT
 AND MAINTAINED
  
2010-03-29 13:34:33 
  
 EFFLUENT GUIDELINES ARE NATIONAL STANDARDS COMPOSED BY
 THE EPA, THAT PROVIDE GUIDANCE FOR WASTEWATER
 DISCHARGES TO SURFACE WATERS. CONSTRUCTION ACTIVITIES
 THAT SIGNIFICANTLY DISTURB THE LAND, SUCH AS CLEARING,
 EXCAVATING AND GRADING ARE KNOWN TO HAVE AN IMPACT ON
 MANY BIOLOGICAL FACTORS IN THE SURROUNDING ENVIRONMENT,
 AND THESE NEW GUIDELINES ARE SET TO TARGET WATER
 QUALITY DEGRADATION.
  
 AS OF FEB 1ST, 2010, CERTAIN SITE OWNERS AND OPERATORS
 ARE NOW REQUIRED TO ESTABLISH BEST MANAGEMENT PRACTICES
 (BMP'S) TO SAMPLE STORMWATER DISCHARGES AND COMPLY WITH
 A NUMERIC SAMPLE FOR POLLUTANT TURBIDITY. POLLUTION
 PREVENTION MEASURES WILL ALSO BE REQUIRED TO CONTROL
 SITE DISCHARGES, SUCH AS DEWATERING AND CONCRETE
 WASHOUT, AND STRICT NEW MEASURES TO PROMOTE SOIL
 STABILIZATION HAVE BEEN PLACED IN EFFECT.
  
 UPGRADES TO THE STATION WILL TRIGGER SURFACE WATER
 QUALITY CALCULATIONS AND WATER QUALITY INLETS.
 PLEASE PROVIDE PRELIMINARY STORWATER CALCULATIONS THAT
 SHOW THAT THE SITE WILL BE ABLE TO PROVIDE ADEQUATE
 TREATMENT OF RUNOFF PRIOR TO DISCHARGE.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 03-12-2010 Cont ID  
Sent By mcarsill Date 03-12-2010 Time 14:02 Rev Time 0.00
Received By mcarsill Date 03-12-2010 Time 13:23 Sent To  
Notes
2010-03-12 13:56:501705 BELVEDERE ROAD
 CLASS B SPECIAL USE
 ZBA 3265 (Z10020007)
  
 1. THE INSTALLATION OF THE UNDERGOUND FUEL TANKS AND
 DISPENSING PUMPS AND HOZES SHALL COMPLY WITH NFPA 30
 AND NFPA 30A.
  
 2. THE EMERGENCY SHUT-OFF FOR THE FUEL DISPENSING
 ISLANDS SHALL BE IN ACCORDANCE WITH NFPA 30A AND BE
 PROPERLY MARKED AND IDENTIFIED.
  
 3. ALL APPLICABLE FIRE CODE REQULATIONS SHALL BE MET
 REGARDING THE OPERATION OF THE GASOLINE / CONVENIENCE
 STORE.
  
 4. PROPER FIRE EXTINGUISHING EQUIPMENT SHALL BE
 PROVIDED, SERVICE TAGGED, AND MAINTAINED.
  
 APPROVED
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION
 WEST PALM BEACH FIRE RESCUE
 500 NORTH DIXIE HIGHWAY
 WEST PALM BEACH, FLORIDA 33401
 (561) 804-4709 PHONE
 (561) 804-4774 FAX

Review Stop L LANDSCAPING
Rev No 2 Status F Date 05-07-2010 Cont ID  
Sent By rkussner Date 05-07-2010 Time 15:04 Rev Time 0.00
Received By rkussner Date 05-07-2010 Time 15:04 Sent To  
Notes
2010-05-07 16:06:11***LANDSCAPE REVIEW FAILED FOR 1705 BELVEDERE ROAD***
  
 PLEASE PROVIDE RESPONSES FOR REVIEW COMMENTS IN WRITTEN
 FORMAT.
  
 1. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 2. REPEAT COMMENT: PURSUANT TO SECTION 94-445 (2), OF
 THE ZONING AND LAND DEVELOPMENT REGULATIONS, PLANT
 MATERIALS USED PURSUANT TO THE PROVISIONS OF THIS
 SECTION SHALL BE EQUAL TO OR BETTER THAN THE FLORIDA
 DEPARTMENT OF AGRICULTURE NUMBER 1 GRADE STANDARD.
 BECAUSE THE EXISTING TREES HAVE BEEN PREVIOUSLY
 "HATRACKED" AND CANNOT MEET THIS REQUIREMENT AND
 BECAUSE THEY ARE GROWING UNDER POWER LINES, ALL TREES
 MUST BE REMOVED AND REPLACED WITH FLORIDA NUMBER 1
 GRADE TREES THAT MEET THE REQUIREMENTS SETFORTH IN
 FPL'S "PLANT THE RIGHT TREE IN THE RIGHT PLACE" GUIDE.
 THIS PUBLICATION PROVIDES A LIST OF TREES THAT CAN BE
 PLANTED NEAR OR UNDER POWER LINES. PURSUANT TO SECTION
 94-446 (2), LANDSCAPING SHALL BE MAINTAINED IN A GOOD
 CONDITION. ALL UNHEALTHY OR DEAD MATERIAL SHALL BE
 REPLACED (TREES, SHRUBS, SOD AND GROUND COVER). ALL
 OTHER PLANT MATERIAL GROWING WITHIN THE HEDGEROWS OTHER
 THAN THE HEDGE SPECIES, SHALL BE REMOVED. THE FICUS
 HEDGE TO REMAIN IS SUBJECT TO WHITE FLY WHICH IS
 AFFECTING FICUS THROUGHOUT SOUTH FLORIDA. PLEASE
 CONSIDER REPLACING THE HEDGE WITH A NEW HEDGE THAT DOES
 NOT HAVE THAT PROBLEM AND PREFERABLY A NATIVE SPECIES.
  
 3. REPEAT COMMENT: A TREE ALTERATION PERMIT IS
 REQUIRED. AN APPLICATION IS AVAILABLE AT THE FRONT DESK
 OF THE PLANNING AND ZONING DEPARTMENT. TREES HAVE
 ALREADY BEEN REMOVED AND OTHERS WILL NEED TO BE
 REMOVED.
  
 4. REPEAT COMMENT: THE TABULATION PROVIDED FOR THE
 EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS IS INCORRECT. THE OPEN
 SPACE IS CALCULATED BY TAKING THE TOTAL SQUARE FOOTAGE
 OF THE ENTIRE SITE AND DEDUCTING THE BUILDING
 FOOTPRINT. THE CALCULATIONS THAT YOU PROVIDED STILL
 INDICATE A DEFICIENCY OF 185 SQUARE FEET THAT NEEDS TO
 BE CORRECTED. BASED UPON YOUR CALCULATIONS, SIX SHADE
 TREES ARE REQUIRED---NOT FIVE. FRACTIONS ARE ROUNDED UP
 TO THE NEXT WHOLE NUMBER. PLEASE REVIEW AND REVISE ALL
 LANDSCAPE CALCULATIONS.
  
 5. REPEAT COMMENT: . PURSUANT TO SECTION 94-444 (B),
 OUTDOOR GARBAGE OR TRASH RECEPTACLES AND ALL OTHER
 MECHANICAL EQUIPMENT SHALL NOT BE PERMITTED UNLESS
 APPROPRIATE SCREENING IS PROVIDED. PURSUANT TO SECTION
 94-444 (B), A FOUR-SIDED ENCLOSURE WITH VISION
 OBSCURING GATES CAN BE A CONDITION OF SITE PLAN
 APPROVAL. THE ENCLOSURE IS REQUIRED TO HAVE VISION
 OBSCURING GATES.
  
 6. REPEAT COMMENT: PLEASE PROVIDE A PARKING LAYOUT AND
 INCLUDE THE STRIPING DETAIL. PURSUANT TO SECTION 94-443
 (C) (3) (A), EACH ROW OF PARKING SPACES SHALL BE
 TERMINATED BY LANDSCAPED ISLANDS OF NOT LESS THAN FIVE
 FEET IN WIDTH (EXCLUDING THE REQUIRED CURB) AND NOT
 LESS THAN THE LENGTH OF THE ADJACENT PARKING STALL. THE
 LANDSCAPED ISLAND SHALL CONTAIN AT LEAST ONE SHADE OR
 FLOWERING TREE. THE HANDICAP MANEUVERING AREA DOES NOT
 MEET MINIMUM ADA REQUIREMENTS. CONSTRUCTION SERVICES
 WILL COMMENT ON HANDICAP ACCESSIBILITY.
  
 7. REPEAT COMMENT: PURSUANT TO SECTION 94-443 (C) (4),
 FOR OTHER PAVED AREAS UTILIZED BY MOTOR VEHICLES,
 INCLUDING AISLES, LOADING AREAS, CIRCULATION AREAS AND
 DRIVE-IN SERVICE AREAS, ADDITIONAL LANDSCAPING SHALL BE
 PROVIDED AS FOLLOWS: FOUR SQUARE FEET OF LANDSCAPED
 AREA SHALL BE REQUIRED FOR EACH 100 SQUARE FEET, OR
 FRACTION THEREOF.
  
 8. REPEAT COMMENT: PURSUANT TO SECTION 94-443 (E), AT
 LEAST 30 PERCENT OF THE LINEAR FEET AROUND THE EXTERIOR
 OF ALL COMMERCIAL STRUCTURES SHALL BE PLANTED WITH
 TREES, SHRUBS OR HEDGES. NO FOUNDATION PLANTING HAS
 BEEN PROVIDED.
  
 9. REPEAT COMMENT: PURSUANT TO SECTION 94-443 (C) )2),
 SHADE TREES MUST BE PLANTED AT 30-FOOT INTERVALS WITHIN
 THE LANDSCAPE BUFFER THAT SEPARATES THE VEHICULAR USE
 AREA FROM AN ADJACENT THOROUGHFARE. TREES SHOWN WITHIN
 THE LANDSCAPE STRIP ALONG THE NORTH PERIMETER EXCEED
 THE THIRTY FOOT SPACING REQUIREMENT.
  
 10. REPEAT COMMENT: PURSUANT TO SECTION 94-442 (D),
 PRIVATE LAND AND PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR
 SIDEWALK SURFACES AND REQUIRED BUFFER STRIPS AND
 LANDSCAPED OPEN SPACE AREAS SHALL BE PLANTED WITH
 GRASS. GRASS AREAS SHALL BE SODDED. THERE ARE AREAS
 WITHIN THE PROPERTY BOUNDARY AT THE SOUTHEAST CORNER OF
 THE SITE AND IN THE RIGHT-OF-WAY ADJACENT TO BELVEDERE
 ROAD THAT ARE PAVED. THIS IS NOT A HANDICAP
 ACCESSIBILITY RAMP. THE PAVEMENT SHALL BE REMOVED FROM
 THESE AREAS AND REPLACED WITH SOD. IN ADDITION, THE
 RIGHT-OF-WAY AREA ALONG THE ACCESS EASEMENT (NORTH SIDE
 OF SITE) SHALL BE SODDED AND MAINTAINED. PLEASE NOTE
 THAT A SABAL PALM HAS GROWN IN THE SIDEWALK AREA ON THE
 EAST SIDE OT THE SITE AND IT NEEDS TO BE REMOVED. THE
 OWNER OF THE PROPERTY IS RESPONSIBLE TO MAINTAIN THE
 RIGHT-OF-WAY, ADJACENT TO THE SITE, INCLUDING ANY
 TREES.
  
 11. REPEAT COMMENT: PURSUANT TO SECTION 94-445 (4) (G)
 (3) (II), IN ALL AREAS THAT ARE TO BE PLANTED IN A
 CULTIVATED LANDSCAPE, IRRIGATION SYSTEMS SHALL BE
 DESIGNED TO HAVE 120 PERCENT COVERAGE. THIS INCLUDES
 RIGHTS-OF-WAY. BECAUSE THE PROPERTY OWNER IS REQUIRED
 TO PROVIDE SOD IN THE RIGHT-OF-WAY AND BECAUSE THIS IS
 A PART OF THE CULTIVATED LANDSCAPE, IRRIGATION IS
 REQUIRED.
  
 12. REPEAT COMMENT: PURSUANT TO SECTION 94-443 (C) (5)
 (A), LANDSCAPE AREAS SHALL BE SEPARATED FROM VEHICULAR
 USE AREAS BY NON-MOUNTABLE, CONCRETE CURBING OF THE
 TYPE CHARACTERIZED AS "TYPE D". THE LANDSCAPE AREAS
 ALONG THE SOUTH PERIMETER OF THE SITE ARE ODDLY SHAPED
 AND ARE NOT CURBED. THESE AREAS SHALL BE RECONFIGURED
 TO ALLOW THE SITE TO FUNCTION BETTER AND CURBED.
  
 13. REPEAT COMMENT: THE PROPOSED HEDGES ALONG THE EAST
 AND SOUTH SIDES OF THE SITE SHALL BE PLANTED ALONG THE
 INTERIOR PERIMETER OF THE LANDSCAPE STRIPS WITH TIERED
 PLANTING ON THE STREET SIDE OF THE HEDGES. THE HEDGES
 SHALL BE PLANTED ALONG THE INTERIOR PERIMETER TO AID IN
 VISIBILITY. THE HEDGE AT THE CORNER IS WITHIN THE
 VISIBILITY TRIANGLE. ALSO, HEDGES PLANTED NEXT TO
 PUBLIC SIDEWALKS NEED CONSTANT MAINTENANCE TO KEEP THEM
 FROM GROWING INTO THE PUBLIC AREA.
  
 14, REPEAT COMMENT: CREDIT WAS TAKEN ON THE XERISCAPE
 CHART FOR A MOISTURE SENSING CONTROLLER OTHER THAN A
 RAIN SWITCH, BUT A NOTE ON THE PLAN INDICATES THAT A
 RAIN SENSOR WILL BE INSTALLED. IF A MOISTURE SENSING
 DEVICE IS BEING USED, PLEASE IDENTIFY THE EQUIPMENT.
 PLEASE IDENTIFY THE EQUIPMENT OR ELIMINATE THE FIVE
 POINTS FROM THE XERISCAPE TABLE. HOWEVER, IF YOU DO NOT
 USE A MOISTURE SENSING CONTROLLER, A RAIN SWITCH IS
 REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop L LANDSCAPING
Rev No 1 Status F Date 03-01-2010 Cont ID  
Sent By rkussner Date 03-01-2010 Time 15:37 Rev Time 0.00
Received By rkussner Date 03-01-2010 Time 15:37 Sent To  
Notes
2010-03-01 16:53:29***LANDSCAPE REVIEW FAILED FOR 1705 BELVEDERE ROAD***
  
 PLEASE PROVIDE RESPONSES FOR REVIEW COMMENTS IN WRITTEN
 FORMAT.
  
 1. PURSUANT TO SECTION 94-445 (2), OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS, PLANT MATERIALS USED
 PURSUANT TO THE PROVISIONS OF THIS SECTION SHALL BE
 EQUAL TO OR BETTER THAN THE FLORIDA DEPARTMENT OF
 AGRICULTURE NUMBER 1 GADE STANDARD. BECAUSE THE
 EXISTING TREES HAVE BEEN PREVIOUSLY "HATRACKED" AND
 CANNTO MEET THIS REQUIREMENT AND BECAUSE THEY ARE
 GROWING UNDER POWER LINES, ALL TREES MUST BE REMOVED
 AND REPLACED WITH FLORIDA NUMBER 1 GRADE TREES THAT
 MEET THE REQUIREMENTS SETFORTH IN FPL'S "PLANT THE
 RIGHT TREE IN THE RIGHT PLACE" GUIDE. THIS PUBLICATION
 PROVIDES A LIST OF TREES THAT CAN BE PLANTED NEAR OR
 UNDER POWER LINES. IN ADDITION, ALL HEDGES TO REMAIN
 SHALL BE IN GOOD CONDITION AND ALL OTHER PLANT MATERIAL
 GROWING WITHIN THE HEDGEROWS OTHER THAN THE HEDGE
 SPECIES, SHALL BE REMOVED. THE FICUS HEDGE TO REMAIN IS
 SUBJECT TO WHITE FLY WHICH IS AFFECTING FICUS
 THROUGHOUT SOUTH FLORIDA. PLEASE CONSIDER REPLACING THE
 HEDGE WITH A NEW HEDGE THAT DOES NOT HAVE THAT PROBLEM
 AND PREFERABLY A NATIVE SPECIES.
  
 2. A TREE ALTERATION PERMIT IS REQUIRED. AN APPLICATION
 IS AVAILABLE AT THE FRONT DESK OF THE PLANNING AND
 ZONING DEPARTMENT. TREES HAVE ALREADY BEEN REMOVED AND
 OTHERS WILL NEED TO BE REMOVED.
  
 3. THE TABULATION PROVIDED FOR THE EVALUATION OF
 COMPLIANCE WITH ARTICLE XIV OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS IS INCORRECT. THE OPEN SPACE IS
 CALCULATED BY TAKING THE TOTAL SQUARE FOOTAGE OF THE
 ENTIRE SITE AND DEDUCTING THE BUILDING FOOTPRINT. THE
 DIFFERENCE IS THE OPEN SPACE. BASED ON A LOT AREA OF
 APPROXIMATELY 17,500 SQUARE FEET AND DEDUCTING THE 880
 SQUARE FOOT BUILDING FOOTPRINT, THE OPEN SPACE IS
 16,620 SQUARE FEET. AS AN EXAMPLE, ELEVEN SHADE TREES
 ARE REQUIRED AND THREE FLOWERING TREES ARE REQUIRED.
 THE OTHER CALCULATIONS NEED TO BE CORRECTED, AS WELL.
  
 4. PURSUANT TO SECTION 94-444 (B), OUTDOOR GARBAGE OR
 TRASH RECEPTACLES AND ALL OTHER MECHANICAL EQUIPMENT
 SHALL NOT BE PERMITTED UNLESS APPROPRIATE SCREENING IS
 PROVIDED. THE ENCLOSURE IS REQUIRED TO HAVE VISION
 OBSCURING GATES.
  
 5. PLEASE PROVIDE A PARKING LAYOUT AND INCLUDE THE
 STRIPING DETAIL. PURSUANT TO SECTION 94-443 (C) (3)
 (A), EACH ROW OF PARKING SPACES SHALL BE TERMINATED BY
 LANDSCAPED ISLANDS OF NOT LESS THAN FIVE FEET IN WIDTH
 (EXCLUDING THE REQUIRED CURB) AND NOT LESS THAN THE
 LENGTH OF THE ADJACENT PARKING STALL. THE LANDSCAPED
 ISLAND SHALL CONTAIN AT LEAST ONE SHADE OR FLOWERING
 TREE.
  
 6. PURSUANT TO SECTION 94-443 (C) (4), FOR OTHER PAVED
 AREAS UTILIZED BY MOTOR VEHICLES, INCLUDING AISLES,
 LOADING AREAS, CIRCULATION AREAS AND DRIVE-IN SERVICE
 AREAS, ADDITIONAL LANDSCAPING SHALL BE PROVIDED AS
 FOLLOWS: FOUR SQUARE FEET OF LANDSCAPED AREA SHALL BE
 REQUIRED FOR EACH 100 SQUARE FEET, OR FRACTION THEREOF.
  
 7. PURSUANT TO SECTION 94-443 (E), AT LEAST 30 PERCENT
 OF THE LINEAR FEET AROUND THE EXTERIOR OF ALL
 COMMERCIAL STRUCTURES SHALL BE PLANTED WITH TREES,
 SHRUBS OR HEDGES. NO FOUNDATION PLANTING HAS BEEN
 PROVIDED.
  
 8. PURSUANT TO SECTION 94-443 (C) )2), SHADE TREES MUST
 BE PLANTED AT 30-FOOT INTERVALS WITHIN THE LANDSCAPE
 BUFFER THAT SEPARATES THE VEHICULAR USE AREA FROM AN
 ADJACENT THOROUGHFARE. TREES SHOWN WITHIN THE LANDSCAPE
 STRIP ALONG THE NORTH PERIMETER EXCEED THE THIRTY FOOT
 SPACING REQUIREMENT.
  
 9. ALL TREES AND PLANT MATERIAL SHALL BE PLANTED AT OR
 SLIGHTLY ABOVE GRADE. THE FIRST HORIZONTAL ROOT AND/OR
 THE TRUNK FLARE SHALL BE VISIBLE AFTER THE TREE HAS
 BEEN INSTALLED. THE THREE INCH LAYER OF MULCH SHALL BE
 PULLED BACK AWAY FROM THE ROOT BALLS OF ALL TREES AND
 SHRUBS AND ONLY A FINE LAYER OF MULCH (NOT MORE THAN
 ONE INCH) SHALL BE APPLIED OVER THE ROOT BALL. THIS
 SHALL BE REFLECTED IN THE PLANTING DETAILS PROVIDED.
  
 10. PURSUANT TO SECTION 94-442 (D), PRIVATE LAND AND
 PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK
 SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN
 SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS
 SHALL BE SODDED. THERE ARE AREAS WITHIN THE PROPERTY
 BOUNDARY AT THE SOUTHEAST CORNER OF THE SITE AND IN THE
 RIGHT-OF-WAY ADJACENT TO BELVEDERE ROAD THAT ARE PAVED.
 THE PAVEMENT SHALL BE REMOVED FROM THESE AREAS AND
 REPLACED WITH SOD. IN ADDITION, THE RIGHT-OF-WAY AREA
 ALONG THE ACCESS EASEMENT (NORTH SIDE OF SITE) SHALL BE
 SODDED AND MAINTAINED. PLEASE NOTE THAT A SABAL PALM
 HAS GROWN IN THE SIDEWALK AREA ON THE EAST SIDE OT THE
 SITE AND IT NEEDS TO BE REMOVED.
  
 11. PURSUANT TO SECTION 94-445 (4) (G) (3) (II), IN ALL
 AREAS THAT ARE TO BE PLANTED IN A CULTIVATED LANDSCAPE,
 IRRIGATION SYSTEMS SHALL BE DESIGNED TO HAVE 120
 PERCENT COVERAGE. THIS INCLUDES RIGHTS-OF-WAY.
  
 12. PURSUANT TO SECTION 94-443 (C) (5) (A), LANDSCAPE
 AREAS SHALL BE SEPARATED FROM VEHICULAR USE AREAS BY
 NON-MOUNTABLE, CONCRETE CURBING OF THE TYPE
 CHARACTERIZED AS "TYPE D". THE LANDSCAPE AREAS ALONG
 THE SOUTH PERIMETER OF THE SITE ARE ODDLY SHAPED AND
 ARE NOT CURBED. THESE AREAS SHALL BE RECONFIGURED TO
 ALLOW THE SITE TO FUNCTION BETTER AND CURBED.
  
 13. THE PROPOSED HEDGES ALONG THE EAST AND SOUTH SIDES
 OF THE SITE SHALL BE PLANTED ALONG THE INTERIOR
 PERIMETER OF THE LANDCAPE STRIPS WITH TIERED PLANTING
 ON THE STREET SIDE OF THE HEDGES.
  
 14, CREDIT WAS TAKEN ON THE XERISCAPE CHART FOR A
 MOISTURE SENSING CONTROLLER OTHER THAN A RAIN SWITCH,
 BUT A NOTE ON THE PLAN INDICATES THAT A RAIN SENSOR
 WILL BE INSTALLED. IF A MOISTURE SENSING DEVICE IS
 BEING USED, PLEASE IDENTIFY THE EQUIPMENT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop POLICE POLICE
Rev No 1 Status F Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date 03-22-2010 Cont ID  
Sent By vnoel Date 03-22-2010 Time 14:38 Rev Time 0.00
Received By vnoel Date 03-22-2010 Time 14:38 Sent To  
Notes
2010-05-06 06:58:131. IT WAS NOTED UPON REVIEW OF THE RE-SUBMITTAL THAT
 THE SIDEWALK ENCROACHES INTO THE PROPERTY AT THE SE
 CORNER. AN EASEMENT OVER THAT PORTION OF THE 5 FOOT
 SIDEWALK NEEDS TO BE GRANTED TO THE CITY. A COPY OF OUR
 STANDARD SIDEWALK EASEMENT IS AVAILABLE UPON REQUEST.
2010-03-22 13:22:461. "OF" AND "COUNTY" ARE MISSPELLED IN LEGAL
 DESCRIPTION. THE COURSE OF "WEST 140 FEET" IS ALSO
 DUPLICATED.
 2. MONUMENTATION MISSING AT SE CORNER.
 3. FLOOD ZONE SHOULD BE "C".
 4. ADD ACREAGE OF PROPERTY.
 5. NAME AND NUMBER OF SURVEYOR IS MISSING.
 6. TOPOGRAPHIC SURVEYS REQUIRE 2 SITE BENCHMARKS.

Review Stop Z ZONING
Rev No 2 Status F Date 05-20-2010 Cont ID  
Sent By lfranco Date 04-29-2010 Time 19:08 Rev Time 0.00
Received By lfranco Date 04-29-2010 Time 19:08 Sent To  
Notes
2010-05-20 19:11:01CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT - **** RESUBMITTAL
 4/26/2010 - FAILED, COMMENTS NOT ADDRESSED ****
  
  
 PLANS AND PLATS REVIEW COMMITTEE
 APRIL 14, 2009
 ZONING BOARD OF APPEALS CASE NO. ZBA 3265
 1705 BELVEDERE ROAD
 CLASS B SPECIAL USE PERMIT -MOTOR FUEL SALES W/
 ACCESSORY CONVENIENCE STORE
  
 COMMENTS:
  
 GENERAL COMMENTS:
  
 1. PROVIDE RESPONSES TO REVIEW COMMENTS IN A WRITTEN
 FORMAT. PLEASE NOTE, IF THE PLANNING AND ZONING
 DEPARTMENT HAS NOT RECEIVED A RESPONSE TO THE PPRC
 COMMENTS WITHIN SIXTY (60) DAYS FROM THE PPRC MEETING,
 THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER
 ACTION SHALL REQUIRE RE-SUBMITTAL OF A NEW DEVELOPMENT
 APPLICATION.
  
 2. PROVIDE REVISIONS ADDRESSING ALL PPRC COMMENTS NO
 LATER THAN MONDAY, APRIL 19, 2010, IN ORDER TO BE
 SCHEDULED TO THE ZBA MAY, 2010, ZONING BOARD OF APPEALS
 MEETING (ALL COMMENTS MUST BE SUFFICIENTLY ADDRESSED),
 OTHERWISE, YOU WILL BE SCHEDULED TO THE NEXT AVAILABLE
 ZONING BOARD MEETING.
 RE-SUBMITTALS MAY BE SUBJECT TO ADDITIONAL COMMENTS.
  
 3. PROVIDE THE FOLLOWING NUMBER OF SETS OF PLANS:
 A. 2 SETS 8 1/2"X11" OF SURVEY; AND ELECTRONIC FILE OF
 ALL PLANS.
  
 JUSTIFICATION STATEMENT/ GENERAL APPLICATION:
  
 4. REVISE JUSTIFICATION STATEMENT TO REFLECT ANY
 WAIVERS THAT MAY BE REQUIRED FOR EXISTING TANKS, ETC.,
 PROVIDE HOURS OF OPERATION FOR THE BUSINESS.
  
 RE-SUBMITTAL: COMMENT DID NOT ADDRESS REQUIRED WAIVER
 OF THE DISTANCE FROM ANOTHER CONVENIENCE STORE.
  
 5. SURVEY: PURSUANT TO APPLICATION REQUIREMENTS (M.),
 PROVIDE CURRENT TITLE POLICY INFORMATION ON SURVEY,
 INCLUDING TOTAL ACREAGE TO THE NEAREST ONE-HUNDREDTH
 (1/100) OF AN ACRE, THE SURVEY SHALL BE A CURRENT ALTA
 SURVEY, NO MORE THAN A YEAR OLD.
  
 RE-SUBMITTAL: COMMENT NOT ADDRESSED.
  
 6. PROVIDE A COPY OF THE DEP PERMIT SHOWING AN
 EXTENSION WAS GRANTED TO REPLACE UNDERGROUND TANKS,
 ETC.
  
 RE-SUBMITTAL: A COPY OF THE DEP PERMIT WAS NOT
 PROVIDED.
  
 SITE PLAN:
  
 7. PURSUANT TO THE ZONING AND LAND DEVELOPMENT
 REGULATIONS ("ZLDR"), SECTION 94-273, EXTRA
 REQUIREMENTS FOR SPECIAL USES, FOR MOTOR VEHICLE FUEL
 SALES (NO SERVICE) AND ACCESSORY CONVENIENCE STORE,
 REQUIRES A CLASS B SPECIAL USE PERMIT, PROVIDE ALL
 INFORMATION PERTINENT INFORMATION REQUIRED IN SECTION
 (46.1)(B.). IF A WAIVER(S) IS NECESSARY, IT IS THE
 RESPONSIBILITY OF THE APPLICANT TO PROVIDE THAT
 INFORMATION ACCORDINGLY. ALSO, SUBMIT REQUIRED
 DOCUMENTS PURSUANT TO ZBA APPLICATION AND WAIVER
 PAYMENT FOR EACH WAIVER REQUESTED. KEEP IN MIND, THAT
 THIS WAIVER(S) REQUEST IS LIMITED TO THIS SECTION.
 PROVIDE OR RESPOND TO THE FOLLOWING COMMENTS:
  
 A. (1) MINIMUM DISTANCES. 100 FEET FROM A RESIDENTIAL
 ZONING DISTRICT AND AT LEAST 250 FEET FROM ANY EXISTING
 CONVENIENCE STORE OR LIKE USE.
  
 RE-SUBMITTAL: A WAIVER IS REQUIRED FOR THE DISTANCE
 FROM A CONVENIENCE STORE, PAYMENT IS REQUIRED PRIOR TO
 THIS APPLICATION BEING SCHEDULED/HEARD FOR THE ZBA
 MEETING (WEDNESDAY, MAY 26TH, DEADLINE FOR WAIVER
 PAYMENT).
  
  
 8. PROVIDE ADA AND REGULAR PARKING SPACE STRIPING
 DETAIL (PURSUANT TO SECTION 94-485(J.)(2) STALL
 PAINTING DETAIL) TO CONFORM TO THE ZONING AND
 DEVELOPMENT REGULATIONS(SEE ATTACHED DETAILS).
  
  
 RE-SUBMITTAL: COMMENT NOT ADDRESSED.
  
 10. PURSUANT TO SECTION 94-443(5)A AND B - PROVIDE
 TYPICAL DETAIL AND DIMENSIONS FOR WHEEL STOPS AND
 CURBING TO SHOW HOW LANDSCAPE AREAS WILL BE SEPARATED
 FROM VEHICULAR USE AREAS.
  
 RE-SUBMITTAL: COMMENT NOT ADDRESSED.
  
 11. PURSUANT TO SECTION 94-485(N)(2) - PROVIDE
 DIMENSIONS OF DRIVE-AISLES, INGRESS/EGRESS.
  
 13. PURSUANT TO SECTION 94-485(Q), TABLE XV-5, ONE
 BICYCLE PARKING SPACE SHALL BE PROVIDED FOR EVERY 20
 AUTOMOBILE PARKING SPACES, OR FRACTION THEREOF. THE
 BICYCLE RACK(S) SHALL COMPLY WITH THE DESIGN STANDARDS
 SET FORTH. PROVIDE DETAIL AND LOCATION.
  
 RE-SUBMITTAL: COMMENT NOT ADDRESSED.
  
 14. SITE DATA: PROVIDE REQUIRED AND PROVIDED DATA ,
 PROVIDE DATA IN A TABLE (MATRIX) TYPE FORMAT FOR IT TO
 BE READILY LEGIBLE: IN ADDITION, PLEASE PROVIDE THE
 FOLLOWING INFORMATION:
  
 A. PROVIDE BREAK-DOWN OF TOTAL PARKING SPACES ON SITE
 DATA THAT MEET SECTION 94-485(N)1B, PURSUANT TO ZONING
 CODE REQUIREMENTS AND PREVIOUS APPROVED PARKING, THERE
 ARE A MINIMUM OF FOUR (4) PARKING SPACES REQUIRED.
  
 RE-SUBMITTAL: COMMENT NOT ADDRESSED.
  
 B. PROVIDE TOTAL PARKING REQUIRED AND PROVIDED FOR
 DISABLED PARKING SPACES, PURSUANT TO SECTION 94-485(O),
 THE LOCATION OF THE CURRENT DOES NOT ALLOW ACCESS TO
 THE CONVENIENCE STORE SINCE THERE IS NOT DELINEATION OF
 A CLEAR PATH TO THE ENTRY-WAY. THERE IS A RAISED
 SIDEWALK THAT DOES NOT MEET ACCESSIBILITY REQUIREMENTS
 FOR THIS SPACE. ADDITIONALLY, THE ADA (DISABLED PARKING
 SPACES) NEED TO HAVE UNINTERRUPTED ACCESS TO THE
 BUILDING, THEY ALSO NEED TO BE LOCATED AT THE CLOSEST
 PROXIMITY TO THE ENTRY OF THE BUILDING ITS SERVING.
  
 RE-SUBMITTAL: COMMENT NOT ADDRESSED.
  
 15. LANDSCAPE PLANS NEED TO CORRELATE WITH THE REVISED
 SITE PLAN ACCORDINGLY.
  
 LANDSCAPE PLAN:
  
 16. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 SEE ROBERT KUSSNER'S LANDSCAPE COMMENTS PROVIDED ON
 MARCH 1, 2010.
 RE-SUBMITTAL: COMMENT NOT ADDRESSED.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: 822-1443
 EMAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 03-09-2010 Cont ID  
Sent By lfranco Date 03-09-2010 Time 09:18 Rev Time 0.00
Received By lfranco Date 03-09-2010 Time 09:20 Sent To  
Notes
2010-03-09 18:02:57CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT - **** FAILED ****
  
  
 PLANS AND PLATS REVIEW COMMITTEE
 APRIL 14, 2009
 ZONING BOARD OF APPEALS CASE NO. ZBA 3265
 1705 BELVEDERE ROAD
 CLASS B SPECIAL USE PERMIT -MOTOR FUEL SALES W/
 ACCESSORY CONVENIENCE STORE
  
 COMMENTS:
  
 GENERAL COMMENTS:
  
 1. PROVIDE RESPONSES TO REVIEW COMMENTS IN A WRITTEN
 FORMAT. PLEASE NOTE, IF THE PLANNING AND ZONING
 DEPARTMENT HAS NOT RECEIVED A RESPONSE TO THE PPRC
 COMMENTS WITHIN SIXTY (60) DAYS FROM THE PPRC MEETING,
 THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER
 ACTION SHALL REQUIRE RE-SUBMITTAL OF A NEW DEVELOPMENT
 APPLICATION.
  
 2. PROVIDE REVISIONS ADDRESSING ALL PPRC COMMENTS NO
 LATER THAN MONDAY, APRIL 19, 2010, IN ORDER TO BE
 SCHEDULED TO THE ZBA MAY, 2010, ZONING BOARD OF APPEALS
 MEETING (ALL COMMENTS MUST BE SUFFICIENTLY ADDRESSED),
 OTHERWISE, YOU WILL BE SCHEDULED TO THE NEXT AVAILABLE
 ZONING BOARD MEETING.
 RE-SUBMITTALS MAY BE SUBJECT TO ADDITIONAL COMMENTS.
  
 3. PROVIDE THE FOLLOWING NUMBER OF SETS OF PLANS:
 A. 2 SETS 8 1/2"X11" OF SURVEY; AND ELECTRONIC FILE OF
 ALL PLANS.
  
 JUSTIFICATION STATEMENT/ GENERAL APPLICATION:
  
 4. REVISE JUSTIFICATION STATEMENT TO REFLECT ANY
 WAIVERS THAT MAY BE REQUIRED FOR EXISTING TANKS, ETC.,
 PROVIDE HOURS OF OPERATION FOR THE BUSINESS.
  
  
 5. SURVEY: PURSUANT TO APPLICATION REQUIREMENTS (M.),
 PROVIDE CURRENT TITLE POLICY INFORMATION ON SURVEY,
 INCLUDING TOTAL ACREAGE TO THE NEAREST ONE-HUNDREDTH
 (1/100) OF AN ACRE, THE SURVEY SHALL BE A CURRENT ALTA
 SURVEY, NO MORE THAN A YEAR OLD.
  
 6. PROVIDE A COPY OF THE DEP PERMIT SHOWING AN
 EXTENSION WAS GRANTED TO REPLACE UNDERGROUND TANKS,
 ETC.
  
 SITE PLAN:
  
 7. PURSUANT TO THE ZONING AND LAND DEVELOPMENT
 REGULATIONS ("ZLDR"), SECTION 94-273, EXTRA
 REQUIREMENTS FOR SPECIAL USES, FOR MOTOR VEHICLE FUEL
 SALES (NO SERVICE) AND ACCESSORY CONVENIENCE STORE,
 REQUIRES A CLASS B SPECIAL USE PERMIT, PROVIDE ALL
 INFORMATION PERTINENT INFORMATION REQUIRED IN SECTION
 (46.1)(B.). IF A WAIVER(S) IS NECESSARY, IT IS THE
 RESPONSIBILITY OF THE APPLICANT TO PROVIDE THAT
 INFORMATION ACCORDINGLY. ALSO, SUBMIT REQUIRED
 DOCUMENTS PURSUANT TO ZBA APPLICATION AND WAIVER
 PAYMENT FOR EACH WAIVER REQUESTED. KEEP IN MIND, THAT
 THIS WAIVER(S) REQUEST IS LIMITED TO THIS SECTION.
 PROVIDE OR RESPOND TO THE FOLLOWING COMMENTS:
  
 A. (1) MINIMUM DISTANCES. 100 FEET FROM A RESIDENTIAL
 ZONING DISTRICT AND AT LEAST 250 FEET FROM ANY EXISTING
 CONVENIENCE STORE OR LIKE USE.
  
 B. (3) MINIMUM SITE DIMENSIONS:
  
 IV. ALL BUILDINGS, SIGNS, PUMPS, PUMP ISLANDS, TANKS,
 VENTS AND CANOPIES SHALL BE LOCATED A MINIMUM OF 25
 FEET FROM PUBLIC RIGHT-OF-WAY LINES.
  * DIMENSIONS NOT SHOWN ON PLAN.
  
 C. (5). ALL RECEPTACLES, TANKS, OR FACILITIES FOR THE
 STORAGE OF COMBUSTIBLES IN EXCESS OF 200-GALLON
 QUANTITIES SHALL BE LOCATED UNDERGROUND AND WITHIN THE
 BUILDING SETBACK LINES. ALL RECEPTACLES, TANKS, OR
 FACILITIES FOR THE STORAGE OF COMBUSTIBLES IN
 200-GALLON OR LESS AMOUNTS SHALL BE LOCATED AND
 MAINTAINED WITHIN BUILDING SETBACK LINES AND IN A
 MANNER ACCEPTABLE TO THE CITY. SHOW SETBACK LINES FOR
 ALL PROPERTY LINES;
  
 D. (6) IN THE EVENT A SERVICE STATION IS VACANT FOR A
 CONTINUOUS PERIOD EXCEEDING ONE YEAR, THE PROPERTY
 OWNER SHALL BE REQUIRED TO REMOVE OR TREAT, IN A SAFE
 MANNER APPROVED BY THE CITY ALL FLAMMABLE MATERIAL
 STORAGE TANKS ON THE SITE. A BOND SUFFICIENT TO COVER
 THE COST OF REMOVAL SHALL BE POSTED PRIOR TO ISSUING A
 BUILDING PERMIT FOR THE FACILITY.
  
  
 8. PROVIDE ADA AND REGULAR PARKING SPACE STRIPING
 DETAIL (PURSUANT TO SECTION 94-485(J.)(2) STALL
 PAINTING DETAIL) TO CONFORM TO THE ZONING AND
 DEVELOPMENT REGULATIONS(SEE ATTACHED DETAILS).
  
 9. THERE IS NO. PROVIDE DETAILS OF DUMPSTER (TRASH
 RECEPTACLE) AND ENCLOSURE ON SITE AND SHOW DIMENSIONS
 ON THE OUTER SIDE OF DUMPSTER PURSUANT TO SECTION
 94-444(B), FIGURE XIV-3. ALSO, THE GATES SHALL MEET
 REQUIREMENTS FOR SCREENING, INCLUDING BEING OF OPAQUE
 MATERIAL. NO CHAIN LINK FENCE W/ SLATS IS PERMITTED.
 10. PURSUANT TO SECTION 94-443(5)A AND B - PROVIDE
 TYPICAL DETAIL AND DIMENSIONS FOR WHEEL STOPS AND
 CURBING TO SHOW HOW LANDSCAPE AREAS WILL BE SEPARATED
 FROM VEHICULAR USE AREAS.
 11. PURSUANT TO SECTION 94-485(N)(2) - PROVIDE
 DIMENSIONS OF DRIVE-AISLES, INGRESS/EGRESS.
  
 12. PURSUANT TO SECTION 94-304(E) - PROVIDE SIGHT
 TRIANGLE AT ALL ROAD INTERSECTIONS WITH DIMENSIONS.
  
 13. PURSUANT TO SECTION 94-485(Q), TABLE XV-5, ONE
 BICYCLE PARKING SPACE SHALL BE PROVIDED FOR EVERY 20
 AUTOMOBILE PARKING SPACES, OR FRACTION THEREOF. THE
 BICYCLE RACK(S) SHALL COMPLY WITH THE DESIGN STANDARDS
 SET FORTH. PROVIDE DETAIL AND LOCATION.
  
 14. SITE DATA: PROVIDE REQUIRED AND PROVIDED DATA ,
 PROVIDE DATA IN A TABLE (MATRIX) TYPE FORMAT FOR IT TO
 BE READILY LEGIBLE: IN ADDITION, PLEASE PROVIDE THE
 FOLLOWING INFORMATION:
  
 A. PROVIDE BREAK-DOWN OF TOTAL PARKING SPACES ON SITE
 DATA THAT MEET SECTION 94-485(N)1B, PURSUANT TO ZONING
 CODE REQUIREMENTS AND PREVIOUS APPROVED PARKING, THERE
 ARE A MINIMUM OF FOUR (4) PARKING SPACES REQUIRED.
  
 B. PROVIDE TOTAL PARKING REQUIRED AND PROVIDED FOR
 DISABLED PARKING SPACES, PURSUANT TO SECTION 94-485(O),
 THE LOCATION OF THE CURRENT DOES NOT ALLOW ACCESS TO
 THE CONVENIENCE STORE SINCE THERE IS NOT DELINEATION OF
 A CLEAR PATH TO THE ENTRY-WAY. THERE IS A RAISED
 SIDEWALK THAT DOES NOT MEET ACCESSIBILITY REQUIREMENTS
 FOR THIS SPACE. ADDITIONALLY, THE ADA (DISABLED PARKING
 SPACES) NEED TO HAVE UNINTERRUPTED ACCESS TO THE
 BUILDING, THEY ALSO NEED TO BE LOCATED AT THE CLOSEST
 PROXIMITY TO THE ENTRY OF THE BUILDING ITS SERVING.
  
 15. LANDSCAPE PLANS NEED TO CORRELATE WITH THE REVISED
 SITE PLAN ACCORDINGLY.
  
 LANDSCAPE PLAN:
  
 16. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 SEE ROBERT KUSSNER'S LANDSCAPE COMMENTS PROVIDED ON
 MARCH 1, 2010.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: 822-1443
 EMAIL: [email protected]
  

  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved