Plan Review Details - Project Z09070010
Plan Review Stops For Project Z09070010
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 08-12-2009 Cont ID  
Sent By lmartine Date 08-12-2009 Time 09:44 Rev Time 0.00
Received By lmartine Date 08-12-2009 Time 09:44 Sent To  
Notes
2009-08-12 09:49:06PLANS ARE TO PRELIMINARY, UNABLE TO PROVIDE
 CONSTRUCTIVE COMMENTS.
 PLEASE CONTACT ME DIRECTLY WITH ANY SPECIFIC CONCERNS.
  
  
 THANK YOU,
 LUIS MARTINEZ
 CONSTRUCTION SERVICES
 561-805-6710

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 08-06-2009 Cont ID  
Sent By efabian Date 08-06-2009 Time 09:10 Rev Time 0.00
Received By EFABIAN Date 08-07-2009 Time 08:58 Sent To  
Notes
2009-08-06 09:12:161. PREFER TO HAVE THE DUMPSTER ENCLOSURE MOVED TO THE
 N.E. CORNER OF THE LOT TO WITHIN THE 5 FEET OF THE
 LANDSCAPING BUFFER OF THE PROPERTY. THIS LOCATION WOULD
 MAKE IT MORE ACCESSIBLE FOR SERVICE.
  
 2. NO PLANTINGS IN THE DRAINAGE EASEMENT LESS THAN A
 MINIMUM DISTANCE OF 5 FEET AWAY FROM OF (ANY) EXISTING
 UTILITIES, CATCH BASINS, PIPES., ETC..
  
 3. GREASE TRAP AND OIL/SAND INTERCEPTORS SHALL BE
 CONSTRUCTED IN ACCORDANCE WITH THE CITY'S STANDARD
 DETAIL GS-7
  
 PLEASE CONTACT THE REVIEWER FOR ANY QUESTIONS:
  
 EMERY P. FABIAN
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 PHONE: 561-822-1200
 FAX: 561-494-1116
  
 EMAIL: [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 07-29-2009 Cont ID  
Sent By mcarsill Date 07-29-2009 Time 15:41 Rev Time 0.00
Received By jrenault Date 08-05-2009 Time 09:06 Sent To  
Notes
2009-07-29 15:40:53ZONING BOARD OF APPEALS CASE NUMBER 3254
  
 1. BUILDING ADDRESS REQUIRED. A MINIMUM OF AT LEAST 6"
 HIGH AND AT LEAST 1" WIDE NUMBERS ARE REQUIRED.
  
 2. ILLUMINATED EXIT SIGNS, EMERGENCY LIGHTING
 APPLIANCES, AND PORTABLE FIRE EXTINGUISHERS ARE
 REQUIRED. PLEASE DISPLAY ALL FIRE SAFETY EQUIPMENT.
  
 3. SEPARATE PLANS AND PERMITS REQUIRED FOR THE
 INSTALLATION OF THE UNDERGROUND FUEL TANKS.
  
 4. PLANS WHEN SUBMITTED SHALL INDICATE THE LOCATION OF
 EMERGENCY STOP EQUIPMENT. ALL WARNING SIGNS, AND FIRE
 EXTINGUISHING EQUIPMENT FOR THE FUEL AREA SHALL BE
 SHOWN.
  
 5. THE INSTALLATION, USE AND OPERATION OF THIS FUEL
 STATION SHALL COMPLY WITH NFPA 30A, MOTOR FUEL
 DISPENSING FACILITIES AND REPAIR GARAGES.
  
 6. THE DISPENSING OF FUELS INTO NON-APPROVED CONTAINERS
 IS PROHIBITED.
  
 7. THE PROPOSED FIRE HYDRANT SHALL MEET UTILITY AND
 FIRE RESCUE STANDARDS.
  
 8. ALL CONSTRUCTION, DEMOLITION, AND RENOVATION IS TO
 COMPLY WITH NFPA 241.
  
 9. ALL FUEL DISPENSING EQUIPMENT TO INCLUDE THE HOSES
 SHALL COMPLY WITH NFPA 30A.
  
 10. APPROVED AND LISTED BREAKAWAY DEVICES WILL BE
 REQUIRED FOR THE FUEL APPURTENANT EQUIPMENT.
  
 11. EMERGENCY PROCEDURES ARE TO BE DEVELOPED FOR THE
 FUEL STATION.
  
 12. THIS LIST SHALL NOT BE CONSIDERED ALL INCLUSIVE FOR
 CODE REQUIREMENTS.
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION
 804-4709 PHONE
 804-4774 FAX

Review Stop L LANDSCAPING
Rev No 2 Status F Date 10-13-2009 Cont ID  
Sent By rkussner Date 10-13-2009 Time 11:54 Rev Time 0.00
Received By rkussner Date 10-13-2009 Time 11:54 Sent To  
Notes
2009-10-13 12:18:11LANDSCAPE REVIEW
  
 PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN
 FORMAT.
  
 1. REPEAT COMMENT: PURSUANT TO SECTION 94-443 (E) (1),
 AT LEAST 30 PERCENT OF THE LINEAR FEET AROUND THE
 EXTERIOR OF ALL COMMERCIAL STRUCTURES SHALL BE PLANTED
 WITH TREES, SHRUBS OR HEDGES. A MINIMUM OF FIVE FEET
 SHALL BE PROVIDED ALONG THE NORTH AND WEST SIDES OF THE
 CORNER STATION BETWEEN THE SIDEWALK AND STRUCTURE. THE
 PROPOSED LANDSCAPE STRIP ON THE NORTH SIDE OF THE
 BUILDING IS LESS THAN FIVE (5) FEET IN WIDTH.
  
 2. 'VM' IS A SYMBOL SHOWN ON THE LANDSCAPE PLAN BUT IT
 CANNOT BE FOUND ON THE PLANT LIST.
  
 3. AN ADDITIONAL ROYAL PALM SHALL BE PLANTED IN THE
 RIGHT-OF-WAY ON THE EAST SIDE OF THE PALM BEACH LAKES
 BOULEVARD ACCESS AISLE, IT SHALL BE THE SAME SIZE AS
 THE OTHER PROPOSED ROYAL PALMS.
  
 4. SHOULD THE NEIGBORING PROPERTY TO THE SOUTH INSTALL
 A PERIMETER HEDGE ALONG THE PROPERTY LINE PRIOR TO
 INSTALLATION OF THIS LANDSCAPE, THE HEDGE ON THIS
 PROPERTY CAN BE DELETED.. THE HEDGE ON THE NEIGHBORING
 PROPERTY CAN BE USED TO MEET THE REQUIREMENTS OF THIS
 PROPERTY FOR AS LONG AS THAT HEDGE EXISTS. HOWEVER,
 SHOULD THE NEIGHBORING HEDGE EVER BE REMOVED, THE OWNER
 OF THIS SITE WILL BE RESPONSIBLE TO INSTALL THE
 REQUIRED HEDGE. TO TAKE ADVANTAGE OF THIS, PLEASE
 INCLUDE A NOTE ON THE LANDSCAPE PLAN.
  
 5. THE PROPOSED PYGMY DATE PALMS ALONG THE FOUNDATION
 OF THE TWO BUILDINGS MAY GROW WIDER THAN THE SPACE
 PROVIDED. PERHAPS THE USE OF TRIPLE ALEXANDER PALMS
 SHOULD BE CONSIDERED BECAUSE THEY WILL GROW TALLER AND
 WILL BE OUT OF THE WAY OF PEDESTRIANS. IN ADDTION THEY
 WILL DO A BETTER JOB OF SOFTENING THE FACADE.
  
 6. THERE ARE SEVERAL CONFLICTS BETWEEN PROPOSED
 UTILITIES AND LANDSCAPING. THE GENERATOR AND GREASE
 TRAP ARE VERY CLOSE TO THE NORTHWEST CORNER OF THE CAR
 WASH AND PROPOSED LIVE OAK TREE. THESE ITEMS SHOULD BE
 SHIFTED AWAY FROM THE BUILDING. THE PROPOSED PALMS AT
 THE NOTHEAST AND NORTHWEST CORNERS OF THE BUILDING
 SHALL BE MOVED AROUND THE CORNER TO THE NORTH SIDE OF
 THE BUILDING. THIS WILL GET THEM OUT OF THE DRAINAGE
 EASEMENT AT THE EAST END OF THE BUILDING AND OUT FROM
 UNDER THE OAK TREE AT THE WEST END OF THE BUILDING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop L LANDSCAPING
Rev No 1 Status F Date 07-27-2009 Cont ID  
Sent By rkussner Date 07-27-2009 Time 16:32 Rev Time 0.00
Received By rkussner Date 07-27-2009 Time 16:32 Sent To  
Notes
2009-07-27 16:32:49LANDSCAPE REVIEW
  
 PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN
 FORMAT.
  
 1. THE LANDSCAPE PLAN SHALL BE DRAWN AT A COMMON SCALE
 SUCH AS 1"=10', 1"= 8' OR 1"=20'.
  
 2. THE LANDSCAPE CALCULATIONS PROVIDED ARE INCORRECT.
 OPEN SPACE MEANS AN OPEN, UNENCLOSED AREA CONSISTING OF
 SETBACKS, LANDSCAPING, BUFFERS, VEHICULAR AND
 PEDESTRIAN CIRCULATION FEATURES, AND SURFACE PARKING.
 WHEN YOU DEDUCT 3,344 SQUARE FEET (TOTAL BUILDING
 FOOTPRINT AREA) FROM THE OVERALL SITE AREA OF 41,708
 SQUARE FEET, THE OPEN SPACE IS EQUAL TO 38,364 SQUARE
 FEET. TWENTY-FOUR SHADE TREES AND 77 SHRUBS ARE
 REQUIRED. PLEASE CORRECT ALL CALCULATIONS.
 AT LEAST ONE FLOWERING TREE IS REQUIRED FOR EACH 6400
 SQUARE FEET. SIX FLOWERING TREES ARE REQUIRED INSTEAD
 OF THE TWO THAT WERE PROPOSED.
  
 3. PURSUANT TO SECTION 94-443 (C) (3), OFF-STREET
 PARKING LOTS CONTAINING AT LEAST 12 INTERIOR PARKING
 SPACES SHALL CONTAIN LANDSCAPE AREAS. THE TOTAL SIZE OF
 SUCH LANDSCAPED AREAS SHALL BE EQUAL TO TEN SQUARE FEET
 FOR EACH PARKING SPACE AND SHALL BE PROVIDED WITHIN THE
 INTERIOR OF AN OFF-STREET PARKING AREA. LANDSCAPED
 AREAS SHALL CONTAIN AT LEAST ONE SHADE OR FLOWERING
 TREE FOR EACH 100 SQUARE FEET OF REQUIRED LANDSCAPED
 AREAS. A MINIMUM OF 75 PERCENT OF ALL TREES THAT ARE
 REQUIRED TO BE PLANTED WITHIN THE INTERIOR OF AN
 OFF-STREET PARKING AREA SHALL BE SHADE TREES.
  
 4. PURSUANT TO SECTION 94-3-443 (C)(4), FOR OTHER PAVED
 AREAS UTILIZED BY MOTOR VEHICLES, INCLUDING AISLES,
 LOADING AREAS, CIRCULATION AREAS AND DRIVE-IN SERVICE
 AREAS, ADDITIONAL LANDSCAPING SHALL BE PROVIDED AS
 FOLLOWS: FOUR SQUARE FEET OF LANDSCAPED AREA SHALL BE
 REQUIRED FOR EACH 100 SQUARE FEET, OR FRACTION THEREOF.
  
 5. PURSUANT TO SECTION 94-443 (C)(3)(A), EACH ROW OF
 PARKING SPACES SHALL BE TERMINATED BY LANDSCAPED
 ISLANDS OF NOT LESS THAN FIVE FEET IN WIDTH AND NOT
 LESS THAN THE LENGTH OF THE ADJACENT PARKING STALL. THE
 LANDSCAPED ISLAND SHALL CONTAIN AT LEAST ONE SHADE OR
 FLOWERING TREE. THE TERMINAL LANDSCAPE ISLAND AT THE
 NORTHWEST CORNER OF THE BUILDING DOES NOT MEET THESE
 REQUIREMENTS. BECAUSE TWO ROWS OF PARKING ARE BEING
 TERMINATED, TWO TREES ARE REQUIRED AND THE LANDSCAPE
 AREA SHALL RUN THE FULL LENGTH OF THE ADJACENT PARKING
 STALLS.
  
 6. PURSUANT TO SECTION 94-443 (E) (1), AT LEAST 30
 PERCENT OF THE LINEAR FEET AROUND THE EXTERIOR OF ALL
 COMMERCIAL STRUCTURES SHALL BE PLANTED WITH TREES,
 SHRUBS OR HEDGES. BECAUSE A TYPICAL PARKING STALL IS 18
 FEET IN LENGTH, THE 20 FOOT SPACES COULD BE REDUCED TO
 18 FEET WITH THE ADDITIONAL AREA BEING CONVERTED INTO
 GREEN SPACE. THE AISLE AND SIDEWALK WIDTH COULD ALSO BE
 REDUCED WITH THE ADDITIONAL AREA BEING CONVERTED INTO
 GREEN SPACE. A MINIMUM OF FIVE FEET SHALL BE PROVIDED
 ALONG THE NORTH AND WEST SIDES OF THE CORNER STATION
 BETWEEN THE SIDEWALK AND STRUCTURE. A PLANTING THAT
 WOULD INCLUDE VERTICAL LANDSCAPE ELEMENTS SHALL BE
 PROVIDED ALONG THE NORTH, WEST AND SOUTH SIDES OF THE
 MAIN BUILDING AND ALONG THE NORTH AND SOUTH SIDES OF
 THE CAR WASH.
  
 7. PURSUANT TO SECTION 94-444 (B), ALL MECHANICAL
 EQUIPMENT SHALL BE SCREENED. IF A GENERATOR OR OTHER
 EQUIPMENT WILL BE INSTALLED, PLEASE SHOW THE LOCATION
 AND THE METHOD OF SCREENING.
  
 8. PURSUANT TO SECTION 94-443 (B) (4), AT LEAST ONE
 SHADE OR FLOWERING TREE SHALL BE PLANTED IN A REQUIRED
 BUFFER STRIP FOR EACH 30 LINEAR FEET OR PORTION
 THEREOF. THERE ARE GAPS ALONG THE SOUTH PROPERTY LINE
 BETWEEN THE PROPOSED TREES THAT EXCEED 30 FEET.
  
 9. THERE IS A UTILITY EASEMENT THAT RUNS ALONG THE
 SOUTH PROPERTY LINE THAT IS IN CONFLICT WITH THE
 REQUIRED LANDSCAPE BUFFER. THE APPLICANT SHALL OBTAIN
 WRITTEN AUTHORIZATION FROM THE EASEMENT HOLDER ALLOWING
 THE PROPOSED LANDSCAPING TO BE INSTALLED.
  
 10. THERE IS AN EXCESSIVE AMOUNT OF CONCRETE THAT IS
 PART OF THE PUBLIC SIDEWALK IN THE RIGHT-OF-WAY AT THE
 INTERSECTION OF AUSTRALIAN AVENUE AND PALM BEACH LAKES
 BOULEVARD. THE EXCESS CONCRETE SHALL BE REMOVED AND
 CONVERTED INTO GREEN SPACE PURSUANT TO APPROVAL FROM
 CITY ENGINEERING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561 822-1462.
  
  

Review Stop PARK PARKING
Rev No 1 Status P Date 08-06-2009 Cont ID  
Sent By ssamuels Date 08-06-2009 Time 19:58 Rev Time 0.00
Received By ssamuels Date 08-06-2009 Time 19:58 Sent To  
Notes
***NONE***

Review Stop POLICE POLICE
Rev No 1 Status F Date 08-05-2009 Cont ID  
Sent By ktucker Date 08-05-2009 Time 10:18 Rev Time 0.00
Received By ktucker Date 08-05-2009 Time   Sent To  
Notes
2009-08-05 10:40:58IN ADDITION TO ADHERING TO THE CITY ORDINANCE,
  
 * WINDOWS NEED TO BE ADDED ON THE EAST SIDE OF THE
 STORE TO VIEW CAR WASH AREA
 * CAMERA PLACEMENT WAS NOT ON THE PLAN, BUT AREAS THAT
 WILL NEED TO BE COVERED ARE: REAR OF STORE, CAR WASH
 ENTRY, FRONT DOOR, SIDES OF STORE, RESTROOM AREA,
 CASHIER AREA, GAS PUMP AREA
 * LIGHTING IN THE REAR OF THE STORE, WALL PACKS NOT
 SHOWN ON PLAN FOR THE BUILDING
 * MIRROR THE ENTRY TO CAR WASH TO GIVE USER VIEW BEHIND
 THEM
 * PEEP HOLE IN OFFICE DOOR, UTILITY AREA AND REAR DOOR
 * PASS THROUGH DRAWER IS NOTED ON PLAN, HOWEVER BULLET
 RESISTANT ENCLOSURE WILL BE NEEDED AROUND CASHIER AREA.
  
 ADDITIONAL COMMENTS WILL BE SUBMITTED WHEN A TENANT
 SUBMITS THE ACTUAL PLAN FOR THE PROPOSED STORE. DUE TO
 THE AREA THIS WILL BE CONSIDERED A HIGH RISK STORE,
 ADDITIONAL SECURITY MEASURES WILL BE REQUIRED.
  
  
  
  
 CONVENIENCE STORES/GAS STATIONS
 LIGHTING
 A. PARKING LOT AND PEDESTRIAN LIGHTING SHALL BE:
 A) HIGH EFFICACY OF GREATER THAN 70 LUMENS PER WATT
 B) A KELVIN TEMPERATURE OF 3,500 K OR GREATER THAN
 KELVIN TEMPERATURE
 C) COLOR RENDERING INDEX (CRI) OF 70 OR GREATER
 D) LAMP LIFE OF 20 THOUSAND HOURS OR GREATER.
 B. LIGHT POLES 10 ??? 15 FOOT HIGH FOR PEDESTRIAN-SCALE
 LIGHTING SHALL BE USED FOR ALL PEDESTRIAN WALKWAYS.
 C. PARKING LOT LIGHTING SHALL USE 20 -25 FOOT POLES.
 D. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS,
 BUILDING ADDRESS NUMBERS, LIGHTING AND
 WALKWAYS.
 E. PROVIDE TIMER CLOCK OR PHOTOCELL SENSOR ENGAGED
 LIGHTING FOR ABOVE OR NEAR ENTRYWAYS AND ALL PEDESTRIAN
 SIDEWALKS FOR DUSK TO DAWN OPERATION.
 F. PROVIDE LIGHTING FOR ENTRANCE SIGN.
 G. LIGHTING ON BUILDINGS SHALL BE AROUND PERIMETER OF
 ALL SIDES AND ON PEDESTRIAN WALKWAY SURROUNDING THE
 BUILDINGS.
 NUMERICAL ADDRESS
 A. ILLUMINATION FOR NIGHTTIME VISIBILITY IS REQUIRED.
 B. BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS
 REQUIRED.
 C. ADDRESS NUMBERS ON DOORS SHALL BE A MINIMUM OF 6
 INCHES HIGH.
 DESIGN
 A. CONVEX MIRRORS SHALL BE INSTALLED AND SIGNS AND
 SHELVES SHALL BE KEPT LOW, WHERE THEY DON???T OBSTRUCT
 EMPLOYEE VIEW.
 B. DROP SAFE SHALL BE INSTALLED.
 C. SIGNAGE INDICATING THAT LITTLE CASH IS KEPT ON HAND
 SHALL BE VISIBLE.
 D. VIDEO SURVEILLANCE EQUIPMENT AND CCTV TO DETER
 ROBBERIES SHALL BE INSTALLED, THEREBY INCREASING THE
 RISK OF IDENTIFICATION. CCTV SHOULD BE INSTALLED TO
 OBSERVE THE PUMP TRANSACTIONS, RECORD ACTIVITIES AND
 TRANSACTIONS OF A CLERK, FRONT AND REAR DOOR, COVER
 HARD TO SEE AREAS, CAR WASH, BATHROOMS, TIRE/WATER
 PUMPS, TELEPHONES AND ATMS.
 E. SILENT ALARMS TO NOTIFY POLICE IN THE EVENT OF A
 PROBLEM SHALL BE INSTALLED.
 F. DOORS NOT IN USE SHALL BE KEPT LOCKED.
 G. REAR DELIVERY DOORS SHALL HAVE A PEEPHOLE, DOOR
 CHIME DETECTOR AND LOCKING MECHANISM ON THE DOOR THAT
 ONLY FUNCTIONS WITH A KEY.
 H. STORE ACCESS DURING LATE NIGHT HOURS SHALL BE
 LIMITED BY INSTALLING BULLET-RESISTANT ENCLOSURES WITH
 PASS-THROUGH WINDOWS.
 I. EXIT DOORS SHALL HAVE HEIGHT MARKERS TO HELP
 WITNESSES PROVIDE MORE COMPLETE DESCRIPTIONS OF
 ASSAILANTS.
 J. DOOR CHIME DETECTORS TO ALERT EMPLOYEES WHEN PERSONS
 ENTER THE STORE SHALL BE INSTALLED.
 K. STORE ACCESS SHALL BE CONTROLLED WITH DOOR BUZZERS
 FOR NIGHTTIME USE OR CLOSING HOURS.
 L. BATHROOMS SHALL BE LOCATED IN A CONSPICUOUS LOCATION
 WHERE THERE WILL BE A HIGH VOLUME OF PEDESTRIAN
 TRAFFIC. KEY CONTROL SHOULD BE USED FOR ACCESS.
 M. CASHIER STATION AREA SHALL BE PLACED AT THE FRONT OF
 THE STORE FOR GOOD VISIBILITY AND ENHANCED NATURAL
 SURVEILLANCE.
 N. STORAGE AREAS WITH EXTERIOR ROLL-UP DOORS SHALL BE
 TARGET HARDENED (I.E., SECURED LOCKS CONNECTED TO ALARM
 SYSTEM).
 O. FUEL TANKS AND FUEL PUMPS SHALL BE PLACED IN AN
 ISOLATED AREA OF THE PARKING LOT AWAY FROM BUILDINGS
 AND FLOW OF PARKING LOT TRAFFIC. FUEL TANKS AND FUELS
 PUMPS SHALL BE SECURED AREAS (NOT EASILY ACCESSIBLE).
 P. ATM INSTALLATION SHALL MEET FSS 655-965
 REQUIREMENTS.
 Q. ATM SHOULD BE LOCATED WITHIN SIGHT OF CASHIER.
 R. AVOID PLACEMENT OF ATM BY THE ENTRANCE OF THE STORE.
 S. THE INSTALLATION OF THE ATM SHOULD BE PHYSICALLY
 ATTACHED TO THE FLOOR.
  
  
  

Review Stop STORM STORMWATER
Rev No 1 Status F Date 07-27-2009 Cont ID  
Sent By jrenault Date 07-27-2009 Time 15:18 Rev Time 0.00
Received By jrenault Date 07-27-2009 Time 15:18 Sent To  
Notes
2009-07-27 15:19:291 . PROVIDE CALCULATIONS TO DEMONSTRATE THAT WATER
 QUALITY IS BEING PROVIDED
 2 . PROVIDE CALCULATIONS TO DEMONSTRATE THAT
 POST-CONSTRUCTION SITE RUNOFF DOES NOT EXCEED
 PRE-CONSTRUCTION SITE RUNOFF

Review Stop SURVEY SURVEYING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 08-04-2009 Time   Rev Time 0.00
Received By vnoel Date 08-04-2009 Time 14:19 Sent To  
Notes
2009-08-04 14:15:231. REPLAT WILL BE REQUIRED. A SEPARATE APPLICATION WILL
 NEED TO BE MADE THROUGH ENGINEERING SERVICES.
 2. THE 10' FPL EASEMENT NEEDS TO BE TERMINATED BY FPL
 AS IT CONTAINS CONFLICTING INFORMATION AND A NEW
 EASEMENT GRANTED.
 3. PROPOSED LANDSCAPING ALONG SOUTH LINE MAY INTERFERE
 WITH EXISTING FPL LINE.
 4. THE PLATTED ANCHOR EASEMENT WILL NEED TO BE
 ABANDONED BY THE CITY.
 5. THE PROPOSED UTILITY EASEMENT CAN BE DEDICATED BY
 THE REPLAT.

Review Stop TRAFFIC TRAFFIC ENGINEERING
Rev No 1 Status F Date 08-07-2009 Cont ID  
Sent By bcollins Date 08-07-2009 Time 09:01 Rev Time 0.00
Received By bcollins Date 08-07-2009 Time 09:00 Sent To  
Notes
2009-08-07 08:55:48PARKING SPACES ON WEST SIDE OF BUILDING WILL FORCE
 VEHICLES TO BACK OUT INTO DRIVEWAY ON AUSTRALIAN. NEED
 STOP/RIGHT TURN ONLY SIGN AT AUSTRALIAN EXIT. BOTH
 ACCESS POINTS IN COUNTY ROW.

Review Stop Z ZONING
Rev No 1 Status F Date 08-06-2009 Cont ID  
Sent By kdfreema Date 08-06-2009 Time 13:55 Rev Time 0.00
Received By kdfreema Date 08-06-2009 Time 13:55 Sent To  
Notes
2009-08-06 15:19:471. PARKING LOT STRIPING DETAIL DOES NOT COMPLY WITH
 CITY DETAIL. PLEASE REVISE ACCORDINGLY.
  
 2. THE PLACEMENT OF THE DUMPSTER ENCLOSURE DOES NOT
 APPEAR TO LEND ITSELF TO EASY ACCESS WITH A GARBAGE
 TRUCK. ANGLING IT TO THE LEFT OR RIGHT TO PERMIT A
 TRUCK TO APPROACH THE ENCLOSURE AND REVERSE WITHOUT
 POTENTIAL CONFLICTS WITH THE FUEL PUMPS WOULD RESULT IN
 A SAFER SITUATION.
  
 3. THE DIMENSIONS OF THE DUMPSTER ENCLOSURE SHOWN ON
 THE SITE PLAN DO NOT MATCH THOSE DIMENSIONS SHOWN ON
 THE DUMPSTER DETAIL. PLEASE ENSURE THAT THE SITE PLAN
 ACCURATELY REFLECTS THE DIMENSIONS OF THE STANDARD CITY
 DETAIL.
  
 4. PLEASE PROVIDE DETAILS OF THE IRRIGATION WELL. WILL
 ALL OF THE EQUIPMENT BE LOCATED IN AN UNDERGROUND
 ENCLOSURE OR WILL SOME OF THE EQUIPMENT BE LOCATED
 ABOVE GROUND? PLEASE NOTE THAT ADDITIONAL SCREENING MAY
 BE REQUIRED IF EQUIPMENT IS LOCATED ABOVE GROUND.
  
 5. THE LOADING ZONE PROVIDED ON THE WEST SIDE OF THE
 BUILDING DOES NOT MEET THE MINIMUM 10 X 25 FOOT
 DIMENSION.
  
 6. SHEET C-4 SHOWS A SANITARY DRAIN FOR THE DUMPSTER
 ENCLOSURE. PLEASE NOTE THAT IF THERE IS TO BE A DRAIN
 THE ENCLOSURE, A ROOF OVER THE ENCLOSURE MUST BE
 PROVIDED SO THAT RAINWATER DOES NOT GET INTO THE DRAIN.
  
 7. PLEASE PROVIDE A RECORDED COPY OF THE UNITY OF TITLE
 FILED TO JOIN THE TWO PARCELS WHICH COMPRISE THIS SITE.
  
 8. WITH RESPECT TO THE PROPOSED CARWASH, PLEASE PROVIDE
 INFORMATION REGARDING HOURS OF OPERATION AS WELL AS IF
 ANY BLOWERS ARE PROPOSED. ALSO, AN OPEN WALL SHOULD BE
 PROVIDED ON THE SOUTH SIDE OF THE CARWASH BUILDING TO
 INCREASE VISIBILITY.
  
 9. THE SITE PLAN AND LANDSCAPE PLAN ARE INCONSISTENT
 WITH RESPECT TO THE LOCATION OF THE HANDICAP PARKING
 STALL. PLEASE REVISE PLANS SO THEY ARE CONSISTENT.
  
 10. PLEASE PROVIDE AN ELEVATION VIEW OF THE "MAX
 CLEARANCE" SIGN AT THE CARWASH.
  
 11. A TRAFFIC CONCURRENCY LETTER FROM THE PALM BEACH
 COUNTY TRAFFIC DIVISION IS REQUIRED.
  
 PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1458
 OR [email protected] WITH QUESTIONS.