Plan Review Details - Project E23030044
| Plan Review Stops For Project E23030044 |
| Review Stop |
ENG-A |
ENGINEERING FORMAL REVIEW |
| Rev No |
1 |
Status |
F |
Date |
04-26-2023 |
|
|
Cont ID |
|
| Sent By |
lquinone |
Date |
04-26-2023 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
04-26-2023 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2023-04-26 14:34:39 | E23030044 BELMART PLAZA, 638 BELVEDERE - INITIAL REVIEW | | | 3.30.23 | | | | | | NO COMMENTS FROM RICK ROSSANO, PROJECT COORDINATOR, | | | ENGINEERING SERVICES DEPT., 561-494-1098 | | | [email protected] : | | | | | | | | | NO COMMENTS FROM MARK HURLEY, FIELD CUSTOMER SERVICE | | | SUPER., WPB PUBLIC UTILITIES, 561-822-2262 OR | | | [email protected]: | | | | | | | | | COMMENTS FROM TRACY WARD, SR. STORMWATER ENG., | | | ENGINEERING SERVICES, [email protected] 561-494-1120: | | | 1. UPDATE THE LIST OF CONTACTS ON THE COVER SHEET. | | | 2. LIST THE VERTICAL DATUM REFERENCE ON EVERY SHEET | | | WITH ELEVATION INFORMATION AND PROVIDE THE CONVERSION | | | EQUATION TO NGVD1929. | | | 3. INCLUDE 18??? OR 24??? SUMP IN THE DRAINAGE INLET. | | | INCLUDE A WEEP HOLE IF WATER TABLE IS MORE THAN TWO | | | FEET BELOW THE BOTTOM OF THE STRUCTURE. | | | 4. PROVIDE PARKING SPACE STRIPING DETAIL. SEE CITY | | | DEVELOPMENT CODE SECTION 94-485 FOR APPROPRIATE | | | DIMENSIONS. | | | | | | | | | COMMENTS FROM RICKY ELIZONDO, PUB. UTILITIES PLANS | | | EXAMINER, [email protected] , 561-494-1101: | | | -EXISTING WATER MAIN ON GEORGIA AVE. NOT SHOWN | | | -SHOW AND LABEL ALL EXISTING VALVES/APPURTENANCES FOR | | | WATER AND SEWER | | | -SHOW ALL EXISTING DRY UTILITIES | | | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | | CONCERNS, THANKS. | | | |
|
|
| Review Stop |
ENG-D |
ENGINEERING DEFICIENCY REVIEW |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG-E |
ENGINEERING ENVR. MIT. REVIEW |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG-F |
ENGINEERING FINAL DRAWING REV |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG-M |
ENGINEERING MODIFICATION REV |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG-P |
ENGINEERING PLANNING REVIEW |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG-T |
ENGINEERING TRAFFIC STUDY REV |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| |
Print |
|
Account Summary | Usage Policy | Privacy Policy