| 2014-06-27 15:10:38 | LAND DEVELOPMENT REVIEW COMMENTS |
| | BELMART PLAZA PUBLIX |
| | PROJECT E14060020 |
| | |
| | PLEASE RESPOND TO THE FOLLOWING COMMENTS IN WRITTING. |
| | |
| | SITE PLAN |
| | PLEASE SUBMIT ONE (1) COMPLETE SET OF APPROVED SITE |
| | PLAN DRAWINGS. THE APPROVED DRAWINGS WILL HAVE BEEN |
| | STAMPED BY THE CITY OF WEST PALM BEACH PLANNING |
| | DEPARTMENT. |
| | |
| | SUPPORTING DOCUMENTATION |
| | PLEASE SUBMIT COPIES OF REGULATORY PERMIT APPROVALS |
| | (I.E. FDEP SELF-CERTIFICATION FOR A STORMWATER |
| | MANAGEMENT SYSTEM IN UPLANDS SERVING LESS THAN 10 ACRES |
| | OF TOTAL PROJECT AREA AND LESS THAN 2 ACRES OF |
| | IMPERVIOUS SURFACE OR SFWMD PERMIT, PALM BEACH COUNTY |
| | PERMIT FOR WORK WITHIN BELVEDERE ROAD RIGHT-OF-WAY). |
| | THE SUBMITTED BOUNDARY SURVEY WAS NOT SIGNED OR SEALED. |
| | PLEASE SUBMIT A SIGNED AND SEALED COPY OF THE BOUNDARY |
| | SURVEY. |
| | PLEASE PROVIDE A COPY OF THE PROPOSED STORMWATER |
| | POLLUTION PREVENTION PLAN. |
| | PLEASE REVISE THE COST ESTIMATE TO INCLUDE ONLY THE |
| | CONSTRUCTION PROPOSED WITHIN THE CITY?S EASEMENTS OR |
| | RIGHT-OF-WAYS. (SEE ATTACHED) |
| | PLEASE PROVIDE COPIES OF THE FIRE FLOW AND STORMWATER |
| | CALCULATIONS. |
| | |
| | CONSTRUCTION PLANS |
| | SHEET C-02: NOTES 1 AND 7 REFER TO A BOUNDARY SURVEY |
| | WITH A REVISION DATE OF 2012. THE SUBMITTED SURVEY |
| | SHOWS A REVISION DATE OF APRIL 21, 2014. PLEASE VERIFY |
| | THAT THE NOTES REFER TO THE LATEST SURVEY REVISION |
| | DATE. |
| | SHEET C-03: WHERE IS THE CONSTRUCTION FENCE PROPOSED? |
| | THE NOTE BELOW THE CONSTRUCTION FENCE DETAILS |
| | REFERENCES STUDENTS AND SCHOOL PERSONNEL AND DOES NOT |
| | APPEAR TO APPLY TO THIS PROJECT. |
| | SHEET C-04: PLEASE INCLUDE A LEGEND DEFINING THE |
| | VARIOUS LINE TYPES. |
| | AT THE END OF THE SEWER AND WATER SERVICE SEGMENTS |
| | SHOWN AS TO BE REMOVED, PLEASE INCLUDE A DESCRIPTION |
| | FOR PLUGGING/BLOCKING SANITARY SERVICE MAIN THAT WILL |
| | REMAIN IN PLACE. FOR CLARIFICATION ON THE AS-BUILT |
| | DRAWINGS, CONSIDER SHOWING THE REMOVAL NOTES ON SHEET |
| | C-09. |
| | PLEASE SHOW THE LOCATION OF THE EXISTING WATER SERVICE |
| | LINES WITHIN 50 FEET OF THE PROPOSED PUBLIX. PRIMARY |
| | CONCERN IS FOR THOSE LINES WEST OF THE PROPOSED PUBLIX |
| | IN THE VICINITY OF THE PROPOSED SANITARY LATERAL AND |
| | FORCE MAIN EXTENSIONS. |
| | SHEET C-06: PLEASE REVISE THE CALL-OUT FOR CATCH BASIN |
| | C-4 TO INCLUDE THE WEIR FOR THE EXFILTRATION TRENCH. |
| | PLEASE REVISE EITHER THE CALL-OUT FOR THE EXFILTRATION |
| | TRENCH ON THIS SHEET OR THE DESCRIPTION ON THE DETAIL |
| | (SHEET C-07) SO THAT THEY MATCH. |
| | HOW IS THE PROPOSED 15-INCH CMP GOING TO CONNECT TO THE |
| | EXISTING CMP WEST OF CATCH BASIN C-1? (PLEASE PROVIDE A |
| | DETAIL.) |
| | SHEET C-07: THE ELEVATIONS SHOWN ON THE EXFILTRATION |
| | TRENCH DETAIL DO NOT APPEAR TO MATCH THE FINISHED GRADE |
| | OR PIPE INVERT ELEVATIONS SHOWN ON THE PLAN VIEW. THE |
| | TRENCH WIDTH DOES NOT MATCH CALL-OUT ON PLAN SHEET |
| | C-06. PLEASE REVISE THE DETAIL SO IT MATCHES THE |
| | INFORMATION SHOWN ON THE OTHER PLAN SHEETS. PLEASE ALSO |
| | VERIFY THAT SHOWN SEASONAL HIGH WATER ELEVATION IS |
| | APPROPRIATE FOR THIS SITE. |
| | SHEET C-09: IS A NEW WATER SERVICE CONNECTION PROPOSED |
| | OR IS SERVICE PROPOSED TO TIE INTO THE EXISTING |
| | LATERAL, WHICH OUR RECORDS INDICATE IS SERVED BY A |
| | VALVE THAT IS OVER 60 YEARS OLD? IF A NEW CONNECTION IS |
| | NOT PROPOSED, PLEASE ADD A NOTE TO THE PLANS INDICATING |
| | THAT A NEW WATER SERVICE CONNECTION WILL BE REQUIRED IF |
| | CONNECTING TO THE EXISTING LINE IS NOT FEASIBLE. |
| | PLEASE PROVIDE A DETAIL OF THE PROPOSED UTILITY |
| | EASEMENT. THE DDCV WILL BE PRIVATELY OWNED AND SHOULD |
| | BE EXCLUDED FROM THE EASEMENT AREA. |
| | PLEASE PROVIDE CROSSING DETAILS FOR ALL UNDERGROUND |
| | UTILITY CROSSINGS. |
| | WHAT IS THE PURPOSE OF THE PROPOSED STORMWATER MANHOLE |
| | SHOWN SOUTHWEST OF THE NEW LOADING DOCK? |
| | SHEET LP-1: PLEASE VERIFY THAT THE DRIP LINES AND ROOT |
| | ZONES FOR ANY NEW TREES AND SHRUBS WILL BE LOCATED |
| | OUTSIDE OF THE PROPOSED UTILITY EASEMENT. THE CITY WILL |
| | NOT BE RESPONSIBLE FOR REPLACEMENT OF ANY LANDSCAPING |
| | LOCATED WITHIN THE UTILITY EASEMENT. |
| | SHEET LI-1: PLEASE REMOVE THE IRRIGATION FEATURES SHOWN |
| | WITHIN THE PROPOSED UTILITY EASEMENT. |
| | |
| | ADDITIONAL COMMENTS |
| | NPDES AND DEWATERING PERMIT (IF DEWATERING IS PROPOSED) |
| | ARE TO BE SUBMITTED PRIOR TO SCHEDULING PRECONSTRUCTION |
| | MEETING. |
| | AS-BUILT DRAWINGS WILL NEED TO INCLUDE LOCATIONS OF |
| | FP&L CONDUIT, FLORIDA PUBLIC UTILITIES GAS SERVICE |
| | LINE, AT&T CONDUIT. |
| | A DRAFT UTILITY EASEMENT NOT SUBMITTED. PLEASE SUBMIT |
| | PRIOR TO FINAL APPROVAL. |
| | |