Plan Review Details - Project E13020033
Plan Review Stops For Project E13020033
Review Stop ENG-A ENGINEERING FORMAL REVIEW
Rev No 1 Status F Date 05-28-2013 Cont ID  
Sent By mgonzale Date 05-28-2013 Time   Rev Time 20.00
Received By mgonzale Date 05-28-2013 Time   Sent To  
Notes
2013-05-28 12:09:32COMMENTS:
 #1 UPDATE PLAN SHOWING THE CONNECTION TO SEWER AT
 MALVERNE RD. AS AGREED.
 #2 UPDATE DRAINAGE PLAN TO REFLECT CHANGES AS PER
 DICUSSION WITH FDOT AND CITY OF WPB. NO NEW STRUCTURES
 REQUIRED.
 #3 A PERMIT FOR DRIVEWAY(S) OFF SOUTHERN BLVD WILL BE
 REQUIRED FROM FDOT.
 #4 DRIVEWAY OFF MALVERNE WILL REQUIRE A CONCRETE APRON
 AS PER CITY OF WPB STANDARD.
 #5 NO ROOF OVER CITY PICK?UP DUMPSTER AREA. NO FLOOR
 DRAINS WILL BE ALLOWED IN OPEN DUSMPER AREAS,
 #5 FIRELINE TIE?IN WILL REQUIRE A SIZE ON SIZE TEE, NOT
 A DIRECT TAP. NOTE ON PLAN "6"X6" CUT?IN TEE"
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES AND PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822?1200
 DIRECT: (561) 494?1085
 FAX: (561) 494?1116
 MOBILE: (561) 644?7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING

Review Stop ENG-D ENGINEERING DEFICIENCY REVIEW
Rev No 1 Status F Date 05-29-2013 Cont ID  
Sent By Mgonzale Date 05-29-2013 Time   Rev Time 4.00
Received By mgonzale Date 05-29-2013 Time   Sent To I
Notes
2013-05-29 13:19:34COMMENTS:
  
 I REVIEWED THE SUBJECT PLANS (S&S 4/19/13) AND DRAINAGE
 CALCULATIONS (REVISED APRIL 2013) AND OFFER THE
 FOLLOWING COMMENTS:
 1. PLAN SHEET 4 OF 12 CALLS OUT HDPE PIPE BUT
 EXFILTRATION DETAIL AND TYPICAL SECTION A-A ON SHEET 5
 OF 12 SHOW RCP OR SLOTTED RCP PIPE.
 2. ON PLAN SHEET 4 OF 12, DRAINAGE STRUCTURE A7 IS
 LISTED AS TYPE "C" W/ C.I. WHAT IS C.I.?
 3. STRUCTURE A6 SHOULD HAVE A WEIR STRUCTURE FOR
 CONTROL TO KEEP STORMWATER RUNOFF FROM MALVERNE (VIA
 STRUCTURE A7) BACKFEEDING INTO THE ONSITE SYSTEM.
 CONTROL MAY NEED TO BE HIGHER THAN 14.3 IN CASE
 MALVERNE IS REGRADED.
 4. FOR EXISTING DISCHARGE RATE, THE RAINFALL INTENSITY
 SHOULD BE AT THE MINIMUM TIME OF CONCENTRATION, NOT THE
 TOTAL DAILY RAINFALL FOR THE DESIGN STORM. THE 1987
 FDOT DRAINAGE MANUAL CONTAINS
 INTENSITY-DURATION-FREQUENCY CURVES.
 5. DRAINAGE CALCULATIONS SHOW MINIMUM EXFILTRATION
 TRENCH LENGTH OF 65 LINEAR FEET. PLAN SHEET 4 OF 12
 CALLS OUT ONLY 60 LINEAR FEET OF EXFILTRATION TRENCH
 (35' + 25').
 6. 2:1 SLOPE IN DETENTION AREA (SECTION A-A ON SHEET 5
 OF 12) MAY BE DIFFICULT TO MAINTAIN.
 7. SWPPP SHEET 8 OF 12:
 A. SILT FENCE AROUND STRUCTURES IN PAVEMENT IS NOT
 EFFECTIVE. CONSIDER WRAPPING THE GRATES.
 B. GUTTER BUDDIES OR OTHER BMP MAY BE REQUIRED FOR
 INLETS ON SOUTHERN BLVD AND DIXIE HWY.
 8. SIDEWALK EASEMENT AT DRIVEWAY SOUTH OF THE DRIVETHRU
 WILL BE NEEDED (THIS MAY ALREADY HAVE BEEN PROVIDED).
 9. FDOT PERMIT WILL BE NEEDED FOR THE WORK ON SOUTHERN
 BLVD AND DIXIE HWY.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 CITY OF WEST PALM BEACH
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 401 CLEMATIS ST., 4TH FLOOR
 WEST PALM BEACH, FL 33401
 PHONE: 561-494-1120
 FAX: 561-494-1116
 CELL 561-351-0510
 [email protected]

Review Stop ENG-E ENGINEERING ENVR. MIT. REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-F ENGINEERING FINAL DRAWING REV
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-M ENGINEERING MODIFICATION REV
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-P ENGINEERING PLANNING REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-T ENGINEERING TRAFFIC STUDY REV
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***