Plan Review Details - Project E12090016
Plan Review Stops For Project E12090016
Review Stop ENG-A ENGINEERING FORMAL REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-D ENGINEERING DEFICIENCY REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-E ENGINEERING ENVR. MIT. REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-F ENGINEERING FINAL DRAWING REV
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-M ENGINEERING MODIFICATION REV
Rev No 1 Status F Date 04-25-2012 Cont ID  
Sent By Mgonzale Date 04-25-2012 Time   Rev Time 1.00
Received By mgonzale Date 04-19-2012 Time   Sent To I
Notes
2013-04-25 15:19:46PLAN COMMENTS:
  
 STATUS IS FAILED.
  
 #1 PLANS DO NOT SHOW STRAIGHT PIPE DISTANCE BEFORE AND
 AFTER METER.
  
 #2 2" FM CONNECTION IS UNACCEPTABLE WITH SO MANY
 FITTINGS. DIRECT TAPP WOULD BE ACCEPTABLE. FORD 202BS
 DOUBLE BAND BRASS SADDLE.
  
 #3 PROVIDE APPROVED MATERIAL LIST WITH METER BOX
 COATING INTERNAL AND EXTERNAL FOR SEWER COATINGS (USE
 MANHOLE COATING SECTION TO SELECT.)
 HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/
  
 #4 PROVIDE DIMENSIONS AND DISTANCES FROM EXISTING
 STRUCTURE TO PROPOSED STRUCTURE.
  
 #5 METER INSTALL RECOMMENDATIONS MUST MEET
 SPECIFICATION. PROVIDE CROSS SECTION OF 2" METER
 INSTALL SHOWING HORIZONTAL PLACEMENT.
 IT MUST BE INSTALLED IN A MANNER WHERE OPTIMUM METER
 ACCURAZY AND PERFORMANCE IS ACHIEVED. IT IS RECOMMENDED
 TO CONTACT METER SUPPLIER TO ASSIST IN THIS
 INSTALLATION TO ACHIEVE OPTIMUM PERFORMANCE. CONTACT
 CITY METER SHOP FOR METER TECHNICAL SUPPORT CONTACT
 INFORMATION (561) -822-1200.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  
  
  
  
  
  
  
  

Review Stop ENG-P ENGINEERING PLANNING REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-T ENGINEERING TRAFFIC STUDY REV
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved