Plan Review Details - Project E11100001
Plan Review Stops For Project E11100001
Review Stop ENG-A ENGINEERING FORMAL REVIEW
Rev No 2 Status P Date 12-28-2011 Cont ID  
Sent By mgonzale Date 12-26-2011 Time 08:38 Rev Time 0.00
Received By mgonzale Date 12-21-2011 Time 08:38 Sent To  
Notes
2011-12-28 08:41:15PASSED WITH PROVISO
 PLANS CALLS USING A BUTTER FLY VALVE
 PLEASE USE ONLY RESILIENT WEDGE GATE VALVES.
 PLANS ARE INTO PBC HEALTH DEPARTMENT
  
 [email protected]
  
  
  

Review Stop ENG-A ENGINEERING FORMAL REVIEW
Rev No 1 Status F Date 11-21-2011 Cont ID  
Sent By mgonzale Date 11-21-2011 Time   Rev Time 4.00
Received By mgonzale Date 11-21-2011 Time   Sent To  
Notes
2011-11-21 08:19:18TEMPORARY CONSTRUCTION VILLAGE COMMENTS: ESD PERMIT #
 E11100001
  
 #1 PLAN SHOW USING PVC MATERIAL ON THE CITY SIDE, CITY
 ONLY ACCEPTS DIP (DUCTILE IRON PIPE), SHEET 700-CO-017
  
 #2 PLAN LACKS THE PROPERTY LINE AROUND THE ENTIRE SITE.
 THIS IS IMPORTANT TO SHOW ON SHEETS WHERE BMP'S AND
 NPDES ELEMENTS ARE USED TO CONTROL CONSTRUCTION
 ACTIVITY.
  
 #3 PLEASE PROVIDE USAGE INFORMATION FOR WATER AND
 SEWER. GPM, ETC. SPECIFY USING NEPTUNE PROTECTUS IIIS
 FIRE SERVICE METER. SHEET 700-CO-017
 METER VAULT AND BACKFLOW SHOULD BE ORIENTED - RUNNING
 NORTH AND SOUTH SAME AS BACKFLOW.
 NOTE: (6" FIRE PER AWWA 900 - 2,000 (HEAD LOSS 12 PSI)
 (CAN FEED FIRE HYDRANTS ON-SITE AND POTABLE WATER)
 AWWA SAYS 1600 GPM (6PSI LOSS NEPTUNE) = 6? NEPTUNE
 PROTECTUS IIIS FIRE SERVICE METER (HIGH PERFORMANCE)
  
 #4 SHOW A 20' UTILITY EASEMENT OVER THE WATER MAIN
 COVERING FROM THE POINT IT ENTERS PROPERTY UP TO AND
 INCLUDING THE THE 4'X6' METER VAULT.
 (BACKFLOW IS PRIVATE, THERE FORE DO NOT INCLUDE INSIDE
 THIS EASEMENT.) SHEET 700-CO-017
  
 #5 SHOW VERTICAL CLEARANCE OR SEPARATION BETWEEN
 PROPOSED WATER AND EXISTING 4" FM. SHEET 700-CO-017
  
 #6 4" FM SHOULD BE CALLED OUT AS "EXIST. 4" FM"
  
 #7 VERIFY LOCATION FOR EXISTING 4" FM, PLANS SHOWS IT
 BEING INSIDE OF YOUR PROPERTY. IF THIS IS TRUE THEN
 PROVIDE LAYOUT OF FM ACROSS YOUR PROPERTY AND SUPPLY
 EASEMENT INFORMATION.
  
 #8 WATER AND SEWER WILL NEED TO BE SUBMITTED TO PBC
 HEALTH DEPARTMENT.
  
 #9 COST ESTIMATE SHOULD BE REVISED TO INCLUDE ELEMENTS
 THAT WILL REMAIN FOR THE PERMANENT PHASE. PLEASE
 REVISE.
  
 #10 OBTAIN ROW PERMIT FOR WORK WITHIN JOG RD. JOG RD IS
 A PALM BEACH COUNTY ROADWAY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE FEEL FREE TO CONTACT
 MY OFFICE. THANK YOU!
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  

Review Stop ENG-D ENGINEERING DEFICIENCY REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-E ENGINEERING ENVR. MIT. REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-F ENGINEERING FINAL DRAWING REV
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-M ENGINEERING MODIFICATION REV
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-P ENGINEERING PLANNING REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-T ENGINEERING TRAFFIC STUDY REV
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 10-20-2011 Cont ID  
Sent By eschneid Date 10-20-2011 Time 09:17 Rev Time 0.75
Received By eschneid Date 10-20-2011 Time 09:17 Sent To  
Notes
2011-10-20 09:46:55FAILED
  
 1) THE EMERGENCY VEHICLE ACCESS ROUTE (MINIMUM 20 FEET
 WIDE) FROM THE SITE ENTRANCE TO THE CONSTRUCTION
 TRAILER AREA SHALL BE CLEARLY DESIGNATED ON THE PLANS.
 THE PLANS SHALL CLEARLY SHOW AND STATE THAT THE
 EMERGENCY ACCESS ROUTE IS STABILIZED FOR 32 TON
 EMERGENCY VEHICLES.
  
 2) PROVIDE EVIDENCE THAT THE CITY OF WEST PALM BEACH
 POLICE DEPARTMENT CPTED OFFICIAL HAS APPROVED THE
 CONSTRUCTION SITE SECURITY AND MANAGEMENT PLAN. THIS
 PLAN SHALL BE MAINTAINED FOR THE LIFE OF THE
 CONSTRUCTION ACTIVITIES.
  
 3) SHEET 700-CS-002 ?MISCELLANEOUS CIVIL DETAILS? SHALL
 BE CORRECTED AS FOLLOWS (STAFF RECOGNIZES THAT SOME OF
 THE DETAILS MAY NOT SPECIFICALLY APPLY TO THE
 CONSTRUCTION AREA, BUT THE PLANS SHALL ACCURATELY
 REFLECT CITY DETAILS):
 A. PARKING SPACE DETAIL. THE TYPICAL PARKING SPACE
 DETAIL IS INCORRECT. THE REQUIRED 12 INCHES BETWEEN THE
 DOUBLE STRIPES IS NOT SHOWN. PLEASE REFER TO THE
 PARKING STALL DETAIL INCLUDED IN FIGURE XV-2 OF ARTICLE
 XV ?PARKING? OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
 C. WHEEL STOP DETAIL. THE WHEEL STOP DETAIL IS
 INCORRECT. THE CITY STANDARD IS SINGLE SIDED IN
 ACCORDANCE WITH SECTION 94-443(C)(5)B AND FIGURE XIV-2
 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS.
 D. VEHICLE OVERHANG. THE TYPICAL PARKING SPACE DETAIL
 SHOWS THE OVERHANG OF TWO (2) FEET PLUS THE CURB WIDTH.
 FIGURE XIV-2 PROVIDES THAT THE ENTIRE OVERHANG BE TWO
 (2) FEET, INCLUDING THE CURB. THE MULCH AREA SHALL BE
 REDUCED AND THE PLANTING AREA INCREASED ACCORDINGLY TO
 MEET THIS STANDARD.
  
 4) PLEASE PROVIDE THE MATERIAL OF THE NON-HANDICAP
 PARKING SPACES AND DRIVE AISLES ON THE STAGING PLAN.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.
  